KSR Magnetic Level Indicators / Gauges

Størrelse: px
Starte visningen fra side:

Download "KSR Magnetic Level Indicators / Gauges"

Transkript

1 KSR Magnetic Level Indicators / Gauges

2 Magnetic Level Indicators / Gauges Model BNA Applications Chemical industry, petrochemistry, offshore Shipbuilding, engeneering Power stations Pharmacie, food an beverage industry, water purification, environmental industry Special features Designs for temperatures from 160 C to +450 C Designs for a pressure range from full vacuum to 420 bar Special designs: Food industry design, interface measurement, coatings (e.g. enameled), liquid gas, heating jacket Description A communicating bypass chamber is flanged to the side of a vessel, and as the liquid level in the tank rises or falls, a float with a built-in magnetic system inside the chamber rises or falls with it. The chamber is completely sealed so that the only moving part of the apparatus in contact with the liquid is the float itself. On the dry side of the chamber is the KSR Magnetic Roller Display, a column of magnetic rollers which are white on one side and red on the other. The rollers are made from plastic (MRA) or ceramics (MRK) with a distance of 10 mm between their axes. As the fl oat moves up or down the bunched field of the permanent magnet mounted in its top section pulls the rollers through a rotation of 180. As the fl oat rises the rollers are turned from white to red, and as the fl oat falls, they are changed back to white again. This means that at any given time the amount of liquid in the tank is constantly represented by a red column without any external power supply. KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 1 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:30

3 Technical Advantages Simple, robust, and solid design Pressure- and gas-proof separation of chamber and display Measuring and indicating of the level of aggressive, combustible, toxic, hot, agitated and contaminated liquids KSR Magnetic Roller Displays without external power supply Available for applications in all areas of industry through use of highly corrosion-resistant materials Bypass Champer Magnetic system KSR Magnetic Roller Display Type MRA KSR Bypass float Approvals KSR Magnetic switch 94/9/EG KSR Level Sensor Type MG-... TÜV Süd - DGRL 97/23/EG Germanischer Lloyd Det Norske Veritas Rostechnadzor American Bureau of Shipping Page 2 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:34

4 Type Code Code 1 Basic type BNA Magnetic Level Indicator 2 Process connections 1st Key = Nom. size 2nd Key = Nom. pressure 3rd Key = Flange face.../.../... EN... EN 1092 DN 10 - DN PN6 - PN Form B1, B2, C, D... DIN DN 10 - DN 100 PN6 - PN400 Form, C, N, F... ANSI 1/2-4 Class Class 400 Form RF, SF, FF, RTJ JIS... JIS DN 10 - DN K - 63 K Form RF, SF, FF, RTJ GN... Thread male DIN GM... Thread female DIN NPTN... Thread male NPT NPTM... Thrread female NPT S... Welding stubs 3 Option Level Sensor (see separate type code page 25)... MG Basic type without optional code 4 Distance centre-to-centre... M... Distance between fl ange centres in mm 5 Material and chamber dimensions 1st Key = Material 2nd Key = Chamber dimensions.../..x.. V Stainless steel HC Hastelloy C..x.. Chamber OD x Wall thickness in mm L Stainless steel MO Stainless steel (6Mo) VE Stainless steel electro-polished M Monel VTF Stainless steel PTFE-lined PP Polypropylene VET Stainless steel E-TFE-coated PF PVDF VEC Stainless steel E-CTFE-coated G Borosilicate glass 6 Magnetic Roller Display 1st Key = Design 2nd Key = Scale.../... MRA Aluminium housing with plastic rollers SK. with scale (plastic), graduation in cm (printed) MRK Aluminium housing with ceramic rollers SA. Aluminium scale graved MNAV Stainless steel housing with plastic rollers SV. Stainless steel graved MNKV Stainless steel with ceramic rollers P. with sight glass extender (for insulations)) (weitere Typschlüssel auf Seite 19) 7 Option Magnetic Switches 1st Key = Quantity, 3rd Key = Cable length 2nd Key = Execution/Cable type 4th Key = Options.../.../... M. BGU MVE. BGU-V-E - PVC R22 Pre resistance R22 for SPS ME. BGU-E MVD. BGU-V-Exd...T Silikon N NAMUR circuit MS12 BGU-M12 MHT STMU...G PUR according DIN EN MES12 BGU-E-M12 MIL/H STMI-L/H...GA PUR armed MA BGU-A MSDA MSDA MEA BGU-A-E MPS MPS MD. BGU-Exd MPO MPO MV. BGU-V MDA MDA 8 Float (cylindrical) 2nd Key = Diameter/Length in mm 1st KEy = Material 3rd Key = Pressure class 4th Key = Magnetic system Z..S...V... Stainless steel G... Borosilicate glass PN16 PN16 R48H R48H.T... Titanium VEC... Stainless steel PN25 PN25 K92 K92.HC... Hastelloy C E-CTFE-coated K74 K74.CF... CF340.TEC... Titanium A90 A90.PP... Polypropylene E-CTFE-coated A110 A110.PF... PVDF A125 A125 9 Approvals... Ex Ex-Design Ordering examples Basic type Connection size Option level sensor Distance centretocentre Material Chamber dimensions Magnetic Roller display Option Magnetic switch Code BNA - 25 / 16 / B1 - MG - M V60x2 - MRA / SK - 3 / M / 2 - ZVSS Float design Certificates KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 3 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:35

5 Mini-Bypass Magnetic Level Indicators / Gauges of stainless steel Design: BNA -../.. - M... - V42x2 - MRA Pressure Equipment Directive 97/23/EG L... M... 24,5 36,5 M = Centre-to-centre process connection U = Length of float (min. 200 mm) X = Dep. on process connection Mini Magnetic Level Indicators / Gauges Chamber Chamber end top Chamber end bottom Process connection Distance centre-to-centre M... ø 42 x 2 mm Rohrboden Options: (see page 30) - Vent plug - Vent valve - Vent fl ange Flanged with drain plug Options: (siehe Seite 30) - Drain valve - Drain flange Flange EN , DN10 - DN50, PN6 - PN40 Flange ANSI B 16.5, 1/2-2 Class Class 300 Thread stubs G/NPT 1/2-1 Welding stubs1/2-1 (Options see page 31) Min. 150 mm to max mm Material Stainless steel Nominal pressure Max. 16 bar (entsprechend Schwimmerausführung) Temperaturbereich Max. 150 C (according to fl oat design) Float Magnetic roller display Further options: Magnetic switches Level sensors Type ZTS35/185 Material Titanium S.G. min. 800 kg/m³ Pressure max. 16 bar Temperature max. 150 C Type ZBS35/120 Material Buna S.G. min. 800 kg/m³ Pressure max. 6 bar Temperature max. 80 C Type MRA... for technical data and further designs and options see page 19 and 20 see page see page Further Mini-Bypass Magnetic Level Indicators with - Pressure max. 52 bar - Temperature max. 400 C - S.G. min 480 kg/m³ - C/C distance max mm see data sheet at Page 4 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:35

6 Bypass Magnetic Level Indicators / Gauges PN6 - PN40 Design: BNA -../.. - M x.. - MRA (-Ex) Pressure Equipment Directive 97/23/EG 90 ~ 35 U M... X M = Centre-to-centre process connection U = Length of fl oat (min. 200 respectively 220 mm) X = Dep. on process connection PN6 - PN40 Chamber Chamber end top Chamber end bottom Process connection Distance centre-to-centre M... ø 60,3 x 2 mm oder ø 64 x 2 mm Welding cap or fl at top or fl anged Options: (see page 30) - Vent plug - Vent valve - Vent fl ange Flanged with drain plug Options: (see page 30) - Drain valve - Drain fl ange Flange EN , DN10 - DN100, PN6 - PN40 Flange ANSI B 16.5, 1/2-4 Class Class 300 Thread stubs G/NPT 1/2-1 Welding stubs 1/2-1 (Options see page 31) min. 150 mm to max mm (other dimensions on request) Material Stainless steel (316 Ti, 316 L, 904 L) Titanium Grade 2 Hastelloy C Nominal pressure Max. 40 bar (according to flange design) Temperature range -160 C to +450 C (according to design) Float Titan Grade 2 Stainless steel 316Ti Float design according to process parameters S.G., pressure and temperature (see type code page 15-16) Magnetic roller display Typ MRA-M... < 200 C Typ MRK-M... > 200 C for technical data and further designs and options see page 19 and 20 Further options: Magnetic switches Level sensors Electrical trace heating Chamber insulation Explosion protection (Option) see page see page on request on request Ex II 1/2G c T1-T6 KEMA 02 ATEX 2106 X KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 5 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:35

7 Bypass Magnetic Level Indicators / Gauges PN63 and PN100 of stainless steel Design: BNA -../.. - M... - V..x.. - MRA (-Ex) Pressure Equipment Directive 97/23/EG PN63 and PN100 ~ 51 PN63 PN 100 U M ~ M = Centre-to-centre process connection U = Length of float (min. 220 mm) Chamber Chamber end top PN63 PN100 PN63 PN100 Unterer Standrohrabschluss PN63 PN100 Process connection Distance centre-to-centre M... ø 60,3 x 2 mm oder ø 60,3 x 2,6 mm ø 65 x 3,5 mm Welding cap or fl at top or flanged DN50 PN63 bzw. ANSI 2 Class 600 DN50 PN100 bzw. ANSI 2 Class 600 Options: (siehe Seite 30) - Entlüftungsschraube - Entlüftungsventil - Entlüftungsflansch Flanschverbindung DN50 PN63 bzw. ANSI 2 Class 600 DN50 PN100 bzw. ANSI 2 Class 600 mit Ablassschraube Optionen: (siehe Seite 30) - Vent valve - Vent flange Flange EN , DN10 - DN100, PN63 - PN100 Flange ANSI B 16.5, 1/2-4 Class 600 Thread stubs G/NPT 1/2-1 Welding stubs 1/2-1 (Options see page 31) Min. 150 mm to max mm (other dimensions on request) Material Stainless steel Nominal pressure PN63 PN100 Max. 63 bar Max. 100 bar Temperature range -30 C to +300 C (according to design) Float Titan Grade 2 Float design according to process parameters S.G., pressure and temperature (see type code page 19 and 20) Magnetic roller display Type MRA... < 200 C Type MRK... > 200 C for technical data and further designs and options see page 19 and 20 Further options: Magnetic switches Level sensors Electrical trace heating Chamber insulation Explosion protection (Option) See page See page on request on request Ex II 1/2G c T1-T6 KEMA 02 ATEX 2106 X Page 6 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:35

8 Bypass Magnetic Level Indicators / Gauges PN160 and PN250 of stainless steel Design: BNA -../.. - M... - V..x.. - MRA (-Ex) Pressure Equipment Directive 97/23/EG ~ 90 U M (PN160) 210 (PN250) M = Centre-to-centre process connection U = Length of float (min. 220 mm) PN160 and PN250 Chamber Chamber end top PN160 PN250 Chamber end bottom Process connection Distance centre-to-centre M... ø 73,03 x 5,16 mm ø 71 x 7,5 mm Flat top or fl anged ANSI 2 1/2 Class 1500 Options: (see page 30) - Vent plug - Vent valve - Vent fl ange Flanged ANSI 2 1/2 Class 1500 with drain plug Options: (see page 30) - Drain valve - Drain flange Flange EN , DN10 - DN50, PN160 - PN250 Flange ANSI B 16.5, 1/2-2 Class 1500 Thread stubs G/NPT 1/2-1 Welding stubs 1/2-1 (Options see page 31) Min. 150 mm to max mm (other dimensions on request) Material Stainless steel Nominal pressure PN160 PN250 Temperature range PN160 PN250 Max. 160 bar Max. 250 bar -30 C bis +285 C -30 C bis +200 C (according to design) Float Titan Grade 2 Float design according to process parameters S.G., pressure and temperature (see type code page 18) CF 340 solid body material, leakage-proof Magnetic roller display Typ MRA... < 200 C Typ MRK... > 200 C Technische Daten und weitere for technical data and further designs and options see page 19 and 20 Further options: Magnetic switches Level sensors Electrical trace heating Chamber insulation Explosion protection (Option) See page See page on request on request Ex II 1/2G c T1-T6 KEMA 02 ATEX 2106 X KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 7 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:35

9 Bypass Magnetic Level Indicators / Gauges PN400 of stainless steel Design: BNA -../.. - M... - V76x10 - MRA (-Ex) Pressure Equipment Directive 97/23/EG ~ 105 U M M = Centre-to-centre process connection U = Length of fl oat PN400 Chamber Chamber end top Chamber end bottom Process connection Distance centre-to-centre M... ø 76 (ø 76,1) x 10 mm Flat top or fl anged ANSI 2 1/2 Class 2500 Options: (see page 30) - Vent plug - Vent valve - Vent fl ange Flanged ANSI 2 1/2 Class 2500 mit Ablassschraube Optionen: (siehe Seite 30) - Drain valve - Drain flange Flange EN , DN10 - DN50, PN400 Flange ANSI B 16.5, 1/2-2 Class 2500 Thread stubs G/NPT 1/2-1 Welding stubs 1/2-1 (Options see page 31) Min. 150 mm to max mm (other dimensions on request) Material Stainless steel Nominal pressure Max. 400 bar Temperature range -30 C to +70 C (according to design) Float Titan Grade 2 Float design according to process parameters S.G., pressure and temperature on request. Magnetic roller display Further options: Magnetic switches Level sensors Electrical trace heating Chamber insulation Explosion protection (Option) Typ MRA... Technische Daten und weitere for technical data and further designs and options see page 19 and 20 See page See page on request on request Ex II 1/2G c T1-T6 KEMA 02 ATEX 2106 X Page 8 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:35

10 Bypass Magnetic Level Indicators / Gauges with heating jacket of stainless steel Design: BNA -../.. - M... - V60/70 - MRA (-Ex) Pressure Equipment Directive 97/23/EG Process connection Heating jacket connection M... U ~ M = Centre-to-centre process connection U = Length of float (min. 220 mm) Magnetic Level Indicators / Gauges with heating jacket Chamber Heating jacket pipe Chamber end top Chamber end bottom Process connection Heating jacket connection Distance centre-to-centre M... ø 60,3 x 2 mm ø 70 x 2 mm Welding cap Options: - Vent plug - Vent valve - Vent fl ange Flanged with drain Options: - Drain valve - Drain fl ange Flange EN , DN10 - DN100, PN6 - PN40 Flange ANSI B 16.5, 1/2-4 Class 300 Thread stubs G/NPT 1/2-1 Welding stubs 1/2-1 (Options see page 31) Flange EN , DN10 - DN10, PN40 Flange ANSI B 16.5, 1/2-4 Class 300 Thread stubs G/NPT 1/2-1 Welding stubs 1/2-1 Min. 150 mm to max mm (other dimensions on request) Material Stainless steel Nominal pressure Process Heating jacket Max. 16 bar to max. 40 bar (according to fl ange design) Max. 16 bar Temperature range -60 C to +450 C (according to design) Float Titan Grade 2 Float design according to process parameters S.G., pressure and temperature (see type code page 15-16) Magnetic roller display Typ MRA... < 200 C Typ MRK... > 200 C for technical data and further designs and options see page 19 and 20 Further options: Magnetic switches Level sensors Explosion protection (Option) See page See page Ex II 1/2G c T1-T6 KEMA 02 ATEX 2106 X KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 9 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:37

11 Bypass Magnetic Level Indicators / Gauges in Liquid Gas Design of stainless steel Design: BNA -../.. - M... - V88x2 - MRA (-Ex) Pressure Equipment Directive 97/23/EG A A A-A ~42 80 U M... ~ M = Centre-to-centre process connection U = Length of float (min. 220 mm) Liquid Gas Design Chamber Chamber end top Chamber end bottom ø 88,9 x 2 mm Flanged Options: (see page 30) - Vent plug - Vent valve - Vent fl ange Flanged with drain plug Options: (page 30) - Drain valve - Drain flange Process connection Flange ANSI B 16.5, 1/2-4 Class Class 300 Thread stubs G/NPT 1/2-1 Flange EN , DN10 - DN100, PN6 - PN40 Welding stubs 1/2-1 (Options see page 31) Distance centre-to-centre M... Min. 150 mm to max mm Material Stainless steel Nominal pressure Max. 25 bar (according to fl ange design) Temperature range -60 C to +300 C (according to design) Float Titan Grade 2 Float design according to process parameters S.G., pressure and temperature (see type code page 15) Magnetic roller display Typ MRA... < 200 C Typ MRK... > 200 C for technical data and further designs and options see page 19 and 20 Further options: Magnetic switches Level sensors Electrical trace heating Chamber insulation Explosion protection (Option) See page See page on request on request Ex II 1/2G c T1-T6 KEMA 02 ATEX 2106 X Page 10 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:38

12 Bypass Magnetic Level Indicators / Gauges E-CTFE-coated Design: BNA -../16 - M...-VEC64x2 - MRA Pressure Equipment Directive 97/23/EG ~ U M E-CTFE-coated Chamber Chamber end top Chamber end bottom Process connection Distance centre-to-centre M... ø 64 x 2 mm Flanged Options: - Vent flange Flanschverbindung Options: - drain flange Flange EN , DN10 - DN100, PN16 Flange ANSI B 16.5, 1/2-4 Class Class 300 Min. 150 mm to max.... mm (overall chamber length max mm) on dimensions > 2500 mm - chamber separated with flange Material Stainless steel 316 Ti (1.4571) coated E-CTFE internally, Option: anti-static Nominal pressure Temperature range Float Magnetic roller display Further options: Magnetic switches Level sensors Max. 16 bar depending on liquid Stainless steel 316Ti E-CTFE-coated Titanium Grade 2 E-CTFE-coated Float design according to process parameters S.G., pressure and temperature (see type code page 15) Typ MRA... for technical data and further designs and options see page 19 and 20 See page See page ~ 50 M = Centre-to-centre process connection U = Length of float (min. 220 mm) KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 11 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:38

13 Bypass Magnetic Level Indicators / Gauges ETFE-coated Design: BNA -../16 - M... - VET70x2 - MRA Pressure Equipment Directive 97/23/EG ~ ~ 50 U =... M = E-TFE-coated Chamber Chamber end top Chamber end bottom Process connection Distance centre-to-centre M... ø 70 x 2 mm Flanged DN 65 PN 16 or ANSI 2 1/2 Class 150 Options: - Vent fl ange Flanged DN 65 PN 16 or ANSI 2 1/2 Class 150 Options: - Drain flange Flange EN , DN10 - DN100, PN16 Flange ANSI B /2-4 Class Class 300 min. 150 mm to max.... mm (overall chamber length max mm) on dimensions > 2500 mm - chamber separated with flange Material Stainless steel 316 Ti (1.4571) coated E-TFE internally 3-4 mm (Chemresist) Nominal pressure Temperature range Float Magnetic roller display Further options: Magnetic switches Level sensors Max. 16 bar depending on liquid Stainless steel 316Ti E-CTFE-coated Titanium Grade 2 E-CTFE-coated Stainless steel 316Ti PFA-coated Titanium Grade 2 PFA-coated Float design according to process parameters S.G., pressure and temperature (see type code page 15) Typ MRA... for technical data and further designs and options see page 19 and 20 See page See page M = Centre-to-centre process connection U = Length of float (min. 220 mm) Page 12 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:38

14 Bypass Magnetic Level Indicators / Gauges PTFE-lined Design: BNA -../16 - M... - VTF70x2 - MRA Pressure Equipment Directive 97/23/EG 150 U M... ~ PTFE-lined Chamber Chamber end top Chamber end bottom Process connection Distance centre-to-centre M... Material Nominal pressure Temperature range Float Magnetic roller display Further options: Magnetic switches Level sensors ø 70 x 2 mm Flanged Options: - Vent flange Flanged Options: - Drain flange Flange EN , DN25, PN16 Flange ANSI B 16.5, 1 Class Class 300 min. 150 mm to max.... mm (overall chamber length max m on dimensions > 2000 mm - chamber separated with fl ange Stainless steel 316 Ti (1.4571) coated PTFE internally Lining: 3 mm wall thickness, vacuum-proof Option: anti-static Max. 10 bar depending on liquid Stainless steel 316Ti E-CTFE-coated Titanium Grade 2 E-CTFE-coated Stainless steel 316Ti PFA-coated Titanium Grade 2 PFA-coated Float design according to process parameters S.G., pressure and temperature (see type code page 15) Typ MRA... for technical data and further designs and options see page 19 and 20 See page See page M = Centre-to-centre process connection U = Length of float (min. 220 mm) KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 13 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:39

15 Bypass Magnetic Level Indicators / Gauges of PVDF, PP Design: BNA -../16 - M... - PF63x3 - MRA BNA -../16 - M... - PP63x3 - MRA 135 M... U 170 Magnetic Level Indicators / Gauges PVDF, PP Chamber Chamber end top Chamber end bottom ø 63 x 3 mm Welding cap Options: - Threaded fi tting - Vent valve - Vent fl ange Threaded fi tting Options: - Drain valve - Drain fl ange Process connection Flange EN , DN10 - DN50 PN6 - PN 16 Flange ANSI B 16.5, 1/2-2 Class 150 Welding stubs 1/2-1 Distance centre-to-centre M... Material Nominal pressure Min. 200 mm to max mm PVDF, PP Max. 4 bar Temperature range PVDF max. 80 C PP max. 60 C Float Magnetic roller display Further options: Magnetic switches Level sensors PVDF PP Float design according to type code (see page 15) Typ MRA... for technical data and further designs and options see page 19 and 20 See page See page M = Centre-to-centre process connection U = Length of float (mind. 155 mm) Page 14 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:40

16 Cylindrical floats to pressure classes Type Code Max. Pressure bar Max. Temperature C Density kg/m³ Ø mm Length mm Material ZBS 35/ Buna ZPFS PVDF ZPFS PVDF ZPFS PVDF ZPFS PVDF ZPFS PVDF ZPPS PP ZPPS PP ZPPS PP ZPPS PP ZPPS PP ZTS 35/ Titanium (3.7035) ZVSS Stainless steel (1.4571) ZVSS Stainless steel (1.4571) ZVSS Stainless steel (1.4571) ZVSS Stainless steel (1.4571) ZVSS Stainless steel (1.4571) ZVSS Stainless steel (1.4571)) ZVSS Stainless steel (1.4571)) ZTSS ,8 200 Titanium (3.7035) ZTSS ,8 250 Titanium (3.7035) ZTSS ,8 300 Titanium (3.7035) ZTSS ,8 350 Titanium (3.7035) ZTSS ,8 400 Titanium (3.7035) ZTSS ,8 450 Titanium (3.7035) ZVSS 150/PN25/R48H Stainless steel (1.4571) ZVSS 185/PN25/R48H Stainless steel (1.4571) ZVSS 225/PN25/R48H Stainless steel (1.4571) ZVSS 275/PN25/R48H Stainless steel (1.4571) ZVSS 335/PN25/R48H Stainless steel (1.4571) ZVSS 400/PN25/R48H Stainless steel (1.4571) ZVSS 470/PN25/R48H Stainless steel (1.4571) ZVSS 555/PN25/R48H Stainless steel (1.4571) ZVSS 650/PN25/R48H Stainless steel (1.4571) ZVSS 760/PN25/R48H Stainless steel (1.4571) ZTSS 150/PN25/R48H ,8 150 Titanium (3.7035) ZTSS 180/PN25/R48H ,8 180 Titanium (3.7035) ZTSS 215/PN25/R48H ,8 215 Titanium (3.7035) ZTSS 250/PN25/R48H ,8 250 Titanium (3.7035) ZTSS 300/PN25/R48H ,8 300 Titanium (3.7035) ZTSS 355/PN25/R48H ,8 355 Titanium (3.7035) KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 15 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:40

17 Cylindrical floats to pressure classes Type Code Max. Pressure bar Max. Temperature C Density kg/m³ Ø mm Length mm Material ZTSS 410/PN25/R48H ,8 410 Titanium (3.7035) ZTSS 465/PN25/R48H ,8 465 Titanium (3.7035) ZTSS 525/PN25/R48H ,8 525 Titanium (3.7035) ZTSS 595/PN25/R48H ,8 595 Titanium (3.7035) ZTSS 680/PN25/R48H ,8 680 Titanium (3.7035) ZTSS 765/PN25/R48H ,8 765 Titanium (3.7035) ZVS 200/2,5/200/1160/K Stainless steel (1.4571) ZVS 250/2,5/200/960/K Stainless steel (1.4571) ZVS 300/2,5/200/850/K Stainless steel (1.4571) ZVS 350/2,5/200/775/K Stainless steel (1.4571) ZVS 400/2,5/200/720/K Stainless steel (1.4571) ZVS 450/2,5/200/680/K Stainless steel (1.4571) ZTS 150/2,5/200/1380/K Titanium (3.7035) ZTS 200/2,5/200/1000/K Titanium (3.7035) ZTS 250/2,5/200/830/K Titanium (3.7035) ZTS 300/2,5/200/730/K Titanium (3.7035) ZTS 350/2,5/200/660/K Titanium (3.7035) ZTS 400/2,5/200/610/K Titanium (3.7035) ZTS 450/2,5/200/580/K Titanium (3.7035) ZTS 500/2,5/200/550/K Titanium (3.7035) ZTS 150/PN40/K ,8 150 Titanium (3.7035) ZTS 180/PN40/K ,8 180 Titanium (3.7035) ZTS 215/PN40/K ,8 215 Titanium (3.7035) ZTS 255/PN40/K ,8 255 Titanium (3.7035) ZTS 300/PN40/K ,8 300 Titanium (3.7035) ZTS 345/PN40/K ,8 345 Titanium (3.7035) ZTS 405/PN40/K ,8 405 Titanium (3.7035) ZTS 465/PN40/K ,8 465 Titanium (3.7035) ZTS 530/PN40/K ,8 530 Titanium (3.7035) ZTS 610/PN40/K ,8 610 Titanium (3.7035) ZTS 150/PN40/R48H ,8 150 Titanium (3.7035) ZTS 185/PN40/R48H ,8 185 Titanium (3.7035) ZTS 225/PN40/R48H ,8 225 Titanium (3.7035) ZTS 270/PN40/R48H ,8 270 Titanium (3.7035) ZTS 320/PN40/R48H ,8 320 Titanium (3.7035) ZTS 385/PN40/R48H ,8 385 Titanium (3.7035) ZTS 465/PN40/R48H ,8 465 Titanium (3.7035) ZTS 550/PN40/R48H ,8 550 Titanium (3.7035) ZTS 635/PN40/R48H ,8 635 Titanium (3.7035) ZTS 60/150/PN40/K ,8 150 Titanium (3.7035) ZTS 60/180/PN40/K ,8 180 Titanium (3.7035) ZTS 60/210/PN40/K ,8 210 Titanium (3.7035) Page 16 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:40

18 Cylindrical floats to pressure classes Type Code Max. Pressure bar Max. Temperature C Density kg/m³ Ø mm Lenght mm Material ZTS 60/245/PN40/K Titanium (3.7035) ZTS 60/285/PN40/K Titanium (3.7035) ZTS 60/325/PN40/K Titanium (3.7035) ZTS 60/370/PN40/K Titanium (3.7035) ZTS 60/425/PN40/K Titanium (3.7035) ZTS 60/475/PN40/K Titanium (3.7035) ZTS 60/540/PN40/K Titanium (3.7035) ZTS 60/605/PN40/K Titanium (3.7035) ZTS 150/PN64/K ,8 150 Titanium (3.7035) ZTS 180/PN64/K ,8 180 Titanium (3.7035) ZTS 215/PN64/K ,8 215 Titanium (3.7035) ZTS 255/PN64/K ,8 255 Titanium (3.7035) ZTS 295/PN64/K ,8 295 Titanium (3.7035) ZTS 350/PN64/K ,8 350 Titanium (3.7035) ZTS 405/PN64/K ,8 405 Titanium (3.7035) ZTS 470/PN64/K ,8 470 Titanium (3.7035) ZTS 555/PN64/K ,8 555 Titanium (3.7035) ZTS 630/PN64/K ,8 630 Titanium (3.7035) ZTS 150/PN64/R48H ,8 150 Titanium (3.7035) ZTS 180/PN64/R48H ,8 180 Titanium (3.7035) ZTS 215/PN64/R48H ,8 215 Titanium (3.7035) ZTS 260/PN64/R48H ,8 260 Titanium (3.7035) ZTS 315/PN64/R48H ,8 315 Titanium (3.7035) ZTS 370/PN64/R48H ,8 370 Titanium (3.7035) ZTS 445/PN64/R48H ,8 445 Titanium (3.7035) ZTS 515/PN64/R48H ,8 515 Titanium (3.7035) ZTS 605/PN64/R48H ,8 605 Titanium (3.7035) ZTS 685/PN64/R48H ,8 685 Titanium (3.7035) ZTS 150/PN100/K ,8 150 Titanium (3.7035) ZTS 180/PN100/K ,8 180 Titanium (3.7035) ZTS 210/PN100/K ,8 210 Titanium (3.7035) ZTS 250/PN100/K ,8 250 Titanium (3.7035) ZTS 295/PN100/K ,8 295 Titanium (3.7035) ZTS 345/PN100/K ,8 345 Titanium (3.7035) ZTS 400/PN100/K ,8 400 Titanium (3.7035) ZTS 460/PN100/K ,8 460 Titanium (3.7035) ZTS 525/PN100/K ,8 525 Titanium (3.7035) ZTS 605/PN100/K ,8 605 Titanium (3.7035) ZTS 150/PN100/R48H ,8 150 Titanium (3.7035) ZTS 185/PN100/R48H ,8 185 Titanium (3.7035) ZTS 225/PN100/R48H ,8 225 Titanium (3.7035) KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 17 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:40

19 L L L L L Cylindrical floats to pressure classes Type Code Max. Pressure bar Max. Temperature C Density kg/m³ Ø mm Length mm Material ZTS 275/PN100/R48H ,8 275 Titanium (3.7035) ZTS 330/PN100/R48H ,8 330 Titanium (3.7035) ZTS 400/PN100/R48H ,8 400 Titanium (3.7035) ZTS 435/PN100/R48H ,8 435 Titanium (3.7035) ZTS 525/PN100/R48H ,8 525 Titanium (3.7035) ZTS 625/PN100/R49H ,8 625 Titanium (3.7035) ZTKS 50/210/K Titanium (3.7035) ZTKS 50/260/K Titanium (3.7035) ZTKS 50/320/K Titanium (3.7035) ZTKS 50/370/K Titanium (3.7035) ZTKS 50/420/K Titanium (3.7035) ZTKS 50/470/K Titanium (3.7035) ZTKS 50/530/K Titanium (3.7035) ZTKS 50/580/K Titanium (3.7035) ZTKS 59/250/K Titanium (3.7035) ZTKS 59/310/K Titanium (3.7035) ZTKS 59/370/K Titanium (3.7035) ZTKS 59/440/K Titanium (3.7035) ZTKS 59/500/K Titanium (3.7035) ZTKS 59/560/K Titanium (3.7035) ZTKS 59/620/K Titanium (3.7035) ZTKS 59/680/K Titanium (3.7035) Floats Type ZVSS ZTSS Z.SS Type ZTKS Type ZPPS Type ZCFS Type ZTS ZPFS ZVS ZTKS ZPS ZCFS Z.S L L L L L D D D D D D D Page 18 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:40

20 Magnetic Roller Display L... M... L... M ,5 23 M = Measuring range L = M ,5 M = Measuring range L = M + 83 Typ MRA... / Typ MRK... Typ MNAV... / Typ MNKV... Technical data MRA MRK Technical data MNAV MNKV Housing Aluminium anodised Housing Aluminium, Stainless steel-lined Rollers Crastin PBT red and white Ceramics red and white Rollers Crastin PBT red and white Cover Makrolon PC Glass Cover Makrolon PC Glass Max. ambient temperat. 200 C 450 C Max. ambient temperat. 200 C 450 C Ceramics red and white KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 19 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:41

21 L... M... L... M... I Magnet-Rollenanzeige M = Anzeigebereich L = M Additional code Plex /P60 /P60S Sight glass extender M = Measuring range L = M + 83 I = Insulation thickness = Sight glass extender for chamber isolation 60 mm = Sight glass extender for chamber isolation 60 mm with purge Code Description /SKC = Scale in cm (printed adhesive foil) /SKP = Scale in % (printed adhesive foil) /SAC = Scale aluminium engraved in cm /SAM = Scale aluminium engraved in mm /SAP = Scale aluminium engraved in % /SAX = Scale aluminium engraved special /SVC = Scale stainless steel engraved in cm /SVM = Scale stainless steel engraved in mm /SVP = Scale stainless steel engraved in % /SVX = Scale stainless steel engraved special Page 20 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:41

22 Magnetic switches KSR Magnetic switches are used to monitor certain limits of the level. The obtained binary signal can be forwarded to trigger alarms or other controls. Connection diagram blue (1) brown (2) black (3) blue (1) brown (2) black (3) blue (1) brown (2) black (3) 1 switch point 1 switch point Circuit for use on SPS 1 switch point NAMUR-circuit for DIN EN Magnetic roller Display Float Magnetic switch Typ BGU Switch point Contact protection measures Magentic switch RC- Module Load Magnetic switch Diode Load KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 21 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:43

23 Magnetic Switches Reed, Aluminium Housing Design: BGU 32 7 Sliding block for mountng on the left or right of MRA Sliding block for mountng on the left or right of MRA Type BGU-1 PVC BGU-1 Sil BGU-E-1 PVC-blue Cable code Type BGU-M12 BGU-E-M12 Cable Plug Code Typ Code Typ M = BGU-1 PVC MT = BGU-1 Sil ME = BGU-E-1 PVC-blue MS12 = BGU-M12 MES12 = BGU-E-M12 Technical Data Contact Contact type Schaltverhalten Switch rating: Code M, MT Code ME Code adder /N Max. ambient temperature: Code M Code MT Code ME Connection cable: Code M Code MT Code ME Housing Reed contact 1 SPDT bistable Housing protection IP 65 Explosion protection 230 V AC, 60 VA, 1 A; 230 V DC, 30 W, 0,5 A For use in intrinsically safe circuit only with max. 100 ma und max. 30 V For use in control circuits acc. to DIN EN C 150 C T6 to 85 C 3 x 0,75 mm2 1 m PVC-grey 1 m Silicone 1 m PVC-blue Aluminium, anodised (Code ME only) II 1 G Ex ia IIC T6 - T3 LCIE 01 ATEX 6047 X Technical Data Contact Contact type Contact behaviour Switch rating: Code MS12 Code MES12 Codezusatz /N Max. ambient temperature: Code MS12 Code MES12 Connction plug: Code MS12 Housing Reed contact 1 SPDT bistable Housing protection IP 65 Explosion protextion 230 V AC, 60 VA, 1 A; 230 V DC, 30 W, 0,5 A For use in intrinsically safe circuit only with max. 100 ma und max. 30 V For use in control circuits acc. to DIN EN C T6 to 85 C Aluminium, anodised (Code MES12 only) II 1 G Ex ia IIC T6 - T3 LCIE 01 ATEX 6047 X Page 22 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:44

24 Magnetic Switches Reed, Aluminium Housing Design: BGU 32 ~80 Sliding block Sliding block for mounting on the left or right of MRA Sliding block Cable gland for armouredcables Cable gland forcables without armour Technical data Contact Contact type Contact behaviour Switch rating Code MA Code MAE adder /N Max. ambient temperature Code MA Code MAE Housing Terminal housing Code Type MA = BGU-A MAE = BGU-A-E Reed contact 1 SPDT bistable Housing protection IP 65 Explosion protection Contact protection measures see page V AC, 60 VA, 1 A 230 V DC, 30 W, 0,5 A for use in intrinsically safe circuit only with max. 100 ma and max. 30 V for use in control circuits to DIN EN C T6 bis 85 C T5 to 100 C T4 bis135 C T3 to 150 C Aluminium, anodised (Code MAE only) II 1 G Ex ia IIC T6 - T3 LCIE 01 ATEX 6047 X Cable Ex d Code Type MD = BGU-Ex d-1 PVC MDG = BGU-Ex d-1 PUR MDGA = BGU-Ex d-1 PURA MDT = BGU-Ex d-1 Sil Technical data Contact Contact type Contact behaviour Switch rating adder /N Max. ambient temperature Code MD, MDG u. MDGA Code MDT Connection cable Code MD Code MDG Code MDGA Code MDT Housing Reed contact 1 SPDT Housing protection IP 68 Explosion protection Contact protection measures see page 21 bistable 230 V AC, 60 VA, 1 A 230 V DC, 30 W, 0,5 A Zum Anschluss an Steuerstromkreis nach DIN EN T6 to 85 C T6 to 85 C T5 to 100 C T4 to 135 C T3 to 150 C 3 x 0,75 mm2 PVC-grey PUR-yellow PUR-yellow armoured Silicone Aluminium, anodised II 2 G Ex d IIC T6 - T3 LCIE 01 ATEX 6047 X KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 23 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:49

25 Magnetic Switches Reed, Stainless Steel Housing Design: BGU-V 21,3 21, Cable gland for cables without armour Cable gland for armoured cables Cable Code Type MV = BGU-V- PVC MVT = BGU-V- Sil MVE = BGU-V-E- PVC-blue Technical data Cable Ex d Code Type MVD = BGU-V-Ex d- PVC MVDG = BGU-V-Ex d- PUR MVDGA = BGU-V-Ex d- PURA MVDT = BGU-V-Ex d- Sil Technical data Contact Reedkontakt Contact Reedkontakt Contact type 1 Umschalter Contact type 1 Umschalter Contact behaviour bistable Contact behaviour bistable Switch rating Code MV und MVT Code MVE adder /N Max. ambient temperature Code MV Code MVT Code MVE Connection cablel Code MV Code MVT Code MVE 230 V AC, 60 VA, 1 A 230 V DC, 30 W, 0,5 A for use in intrinsically safe circuit only with max. 100 ma and max. 30 V for use in control circuits to DIN EN C 150 C T6 to 85 C 3 x 0,75 mm2 PVC-grey Silicone PVC-blue Housing Stainless steel Housing protection IP 65 Explosion protection II 1 G Ex ia IIC T6 - T3 LCIE 01 ATEX 6047 X (Code MVE only) Switch rating Codezusatz /N Max. ambient temperature Code MVD, MVDG and MVDGA Code MVDT Connection cable Code MVD Code MVDG Code MVDGA Code MVDT 230 V AC, 60 VA, 1 A 230 V DC, 30 W, 0,5 A for use in control circuits to DIN EN T6 to 85 C T6 to 85 C T5 to 100 C T4to 135 C T3 to 150 C 3 x 0,75 mm2 PVC-grey PUR-yellow PUR-yellow armoured Silicone Housing Stainless steel Housing protection IP 68 Explosion protection Contact protection measures see page 21 II 2 G Ex d IIC T6 - T3 LCIE 01 ATEX 6047 X Contact protection measures see page 21 Page 24 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:49

26 Magnetic Switches, Aluminium Housing Design: STM ~70 M 20 x 1,5 ~67 75 M 20 x 1,5 ~110 ~110 Reed High Temperature Initiator Code Type Code Type MHT = STMU Technical Data Contact Contact type Contact behaviour Switch rating adder /N Reedkontakt 1 SPDT Max. ambient temperature 380 C Housing Housing protection IP 65 bistable 230 V AC, 60 VA, 1 A 230 V DC, 30 W, 0,5 A for use in control circuits to DIN EN Aluminium Contact protection measures see page 21 MIH = STMI-H => closing on rising level MIL = STMI-L => closing on falling level Technical Data Contact Contact behaviour Code MIH Funktion Code MIL Funktion Nominal voltage Induktiver Näherungsschalter SJ 3,5-SN bistable High alarm Low alarm Max. ripple < 5 % Supply voltage UB Power consumption active area free active area covered Connection cable max. resistance Self-inductance Self-capacitance 8 V DC (Ri~1 kohm) 5-25 V > 3 ma < 1 ma < 100 Ohm 160 μh 20 nf Ambient temperature -40 C to +100 C Housing Housing protection IP 65 Aluminium KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 25 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:49

27 Level Sensors KSR Level Sensors are used to measure and transmit the level of liquids in conjunction with a KSR control unit. It is based on the fl oat principle with magnetic transmission in a 3-wire potentiometer circuit. A fl oat with a built-in magnetic system actuates small reed contacts through the walls of the bypass chamber. These reed switches form a resistance measuring chain that continuously generates a voltage proportional to the height of the level. The resistance measuring chain is closely stepped and is made up from small chips soldered onto a PCB. Due to this assembly the generated voltage is approximately continuous. Depending on requirements and design several different contact separations are available. Option: Installation of 2-wire transmitter in terminal box possible. Advantage: use in hazardous areas possible Internal circuit diagram level sensors brown blue black Type code Code 3 Basic type MG Level sensor 3.1 Electrical connection (terminal box)... A Aluminium - top APL Polyester - top (Ex-design) AVG Stainless steel - top with digital display AU Aluminium - bottom APLU Polyester - bottom (Ex-design) AVGU Stainless steel - bottom with digital display AP Polyester - top AV4 Edelstahl - top APU Polyester - bottom AV4U Edelstahl - bottom 3.2 1st key Material sensor tube 2nd key Contact separation Optional code.../... V Stainless steel K18 18 mm contact separation 5 / 10 / 15 mm only K15 15 mm /HT.. High temperature +120 C C K10 10 mm /TT.. Low temperature -10 C C K5 5 mm 3.3 (Option) Head mounted transmitter in terminal box... TS 2-wire Standard TE 2-wire Ex i TLH 2-wire HART with LCD display TLEH 2-wire Ex i HART with LCD display T32 2-wire Ex i HART programmable T53P Ex i Profibus PA programmable T53F Foundation Fieldbus programmable 3.4 1st key Sensor tube length 2nd key Measuring range 3rd key Sensor tube dimensions.../.../... L... Length in mm M... Range in mm 14 OD Ø 14 mm 3.5 Optional code... Ex Ex Control circuit EEx ib IIC or EEx ia IIC, resistance of measuring chain: 3.2 kohm kohm Ordering example Basic type Electrical connection Material Sensor tube Contact separation Option Head-mounted transmitter Sensor tube-length Measuring range Sensor tube-dimensions Optional code Code / MG - AU - VK10 - TE / L1650 / M1500 / 14 - Ex Page 26 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:49

28 Level Sensors Ø14 100% 0% 22, M= 50 ~92 75 Type: MG-A.VK../..-L.../M.../14 Terminal box A. = Aluminium, 80 x 75 x 57 mm AP. = Polyester, 80 x 75 x 55 mm AV4. = Stainless steel Sensor tube V = Stainless steel Tube Dia. 14 x 1 mm Type: MG-A.VK../..-L.../M.../14-Ex Explosion protection II 2G Ex ia IIC T4-T6 KEMA 01 ATEX1052X II 2D T 80 C IP6X Terminal box A. = Aluminium, 80 x 75 x 57 mm APL. = Polyester anti-static, 80 x 75 x 55 mm AV4. = Stainless steel Sensor tube V = Stainless steel Tube Dia. 14 x 1 mm Contact separation K18 = 18 mm K15 = 15 mm (HT or TT) K10 = 10 mm (also HT or TT) K5 = 5 mm (also HT or. TT) Contact separation K18 = 18 mm K15 = 15 mm K10 = 10 mm K5 = 5 mm Resistance of measuring chain Standard design depending on length and contact separation Resistance of measuring chain Standard design 3,2 kohm kohm Ambient temperature at sensor tube Standard design -10 C C Type code HT +120 C C Type code TT -10 C C Maximal permissible surface temperature at sensor tube T C T5 +65 C T6 +50 C KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 27 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:50

29 Level Sensors Housing options Type code A. Type code AP. Type code APL. = Aluminium 80 x 75 x 57 mm = Polyester 80 x 75 x 55 mm = Polyester 80 x 75 x 55 mm, anti-static Typcode AVG = Stainless steel with digital display Ø ~93 75 Typcode AV4 = Stainless steel ~125 ~113 Ø 70 Measuring range in mm Page 28 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:50

30 Magnetostrictive Level Sensor The KSR Level Sensors range FFG-BT-... is used for continuous, remote liquid level measurement and based on position monitoring of a magnetic float following the magnetostrictive principle. The sensors are mounted externally on a KSR Bypass Level Indicator. The measuring process is initiated by a current impulse. This current generates an axial magnetic fi eld along the length of a wire made of magnetostrictive material, which is held under tension inside the sensor tube. The Bypass Level Indicator fl oat, which sits on the liquid surface, is fitted with permanent magnets. The magnetic field of the float is at right angles to the impulse magnetic field. When the pulse reaches the float the two magnetic fields interact and a torsional force results. A torsional stress wave is induced in the wire. A piezoceramic pick-up in the sensor housing at the end of the wire converts this into an electrical signal. By measuring the elapsed transit time, it is possible to determine the start point of the torsional stress wave and therefore the float position with a high degree of accuracy. wire 50 permanentmagnet torsional wave impulse magnetic fi eld 100 % permanent magnetic field stainless steell ø 12 mm M =... L =... torsional wave 0 % 30 stainless steel housing Housing protection IP 68 Type FFG-BT-V-L /M /12 Sensor Housing Stainless steel , ingress protection IP 68, cable entry M16 x 1.5 cable entry / gland M16 x 1,5 108 Sensor Tube Ø 12 x 1 mm, Stainless steel Sensor Length Permissible ambient temperature Sensor Tube Sensorgehäuse Connection Supply Voltage Output Signal Error Signal Accuracy Resolution Linearity Load 200 mm mm - 45 C C Standard-Design C C HT-Design - 40 C C 2-wire VDC ma Adjustable to 3,6 ma oder 21,5 ma < ±0,5 mm < 0,1 mm ± 0,1 % (20 C) + 0,005 % / K 900 Ohm bei UB = 30V DC 650 Ohm bei UB = 24V DC 100 Ohm bei UB = 12V DC Ø 52 Type FFG-BT-V-L /M /12-Ex II 2G Ex ib IIC T3-T6 IBExU 02 ATEX 1124X in addition to standard type Permissible ambient temperature: Equipment category 2 T6 T5 T4 T3 Permissible circuit values Sensor Tube Sensor Housing -25 C C -40 C C -25 C C -40 C C -25 C C -40 C C -25 C C -40 C C Type of protection intrinsically safe Ex ib IIC Ui < 30 V Ii < 200 ma Pi < 1 W Li < 250 µh Ci < 5 nf KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 29 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:50

31 Options Chamber ends with dampening spring on request Chamber end top 1 Welding cap 2 Flat top with vent plug BSP 1/2 3 Flanged with vent plug BSP 1/2 4 Flanged e. g. flange facings with groove and tongue acc. to DIN Flat top with vent flange 6 Flanged with vent flange 7 Flat top with vent valve 8 Flat top with vent valve Unterer Standrohrabschluss 9 Flanged with drain plug BSP 1/2 10 Flanged with drain plug BSP 1/2 e.g. fl ange facings with groove and tongue acc. DIN Flanged with drain nozzle 12 Flanged with drain valve 13 Flanged with drain flange Page 30 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:53

32 Options Process connection 14 Welding neck flanges up to DN 25 (1 ) 15 Blind flange above DN 32 (11/4 ) 16 Threaded GN... (Male) 17 Threaded GM... (Female) 18 Welding stub S... Examples Process connection 19 Standard 2 process connections side-side 20 Process connections top and side 21 2 process connections side-side threaded acc. to DIN lower process connection with eccentric reducer 22 2 Process connections top and bottom Option: Support brackets KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 Page 31 von 32 KSR Bypass-Niveaustandsanzeiger.indd :26:57

33 Bosmanskamp 30, 4191 MV Geldermalsen Tel. +31 (0) Fax +31 (0) Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. KSR KUEBLER Niveau-Messtechnik AG Heinrich-Kuebler-Platz Zwingenberg Telefon (+49) Fax (+49) info@ksr-kuebler.com Page 32 von 32 KSR KUEBLER AG Data sheet Magnetic Level Indicator/Gauges 06/2012 Rev. 0 KSR Bypass-Niveaustandsanzeiger.indd :26:57

34 KSR-KUEBLER Niveau-Messtechnik AG Heinrich-Kuebler-Platz Zwingenberg Germany Tel (0) Fax + 49 (0) info@ksr-kuebler.com 06/ Rev. 0 Printed in Germany Technische Änderungen vorbehalten

Technical Specifications

Technical Specifications Technical Specifications Pressure measuring range (bar) 0.1... 0.5, (1) > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar > 200 bar Accuracy, (5), (± % FS)

Læs mere

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals Solenoid valves Control valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)1-73-0 Fax: +49(0)1-73-281 e-mail: info@akmueller.de Internet: www.akmueller.de

Læs mere

Programmable pressure transmitters PTM

Programmable pressure transmitters PTM Programmable pressure transmitters PTM Version: 07.01.2016 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure

Læs mere

WIO200A INSTALLATIONS MANUAL Rev Dato:

WIO200A INSTALLATIONS MANUAL Rev Dato: WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of

Læs mere

Hudevad P200. Technical datasheet

Hudevad P200. Technical datasheet Technical datasheet Key benefits Low, streamlined design Ideal in front of glazing to prevent cold draughts Available in two depths For high flexibility in usage Historical Kundenedfald Grøn energi Flat

Læs mere

Plug Connectors for Food & Beverage

Plug Connectors for Food & Beverage Plug Connectors for Food & Beverage Made with stainless steel Food grade quality High protection degree MeeTS DEMANDING HYGIENIC STANDARDS The food and beverage industry needs an extremely clean environment

Læs mere

Slot diffusers. Slot diffusers LD-17, LD-18

Slot diffusers. Slot diffusers LD-17, LD-18 LD-17, LD-18 Application LD-17 and LD-18 are designed for supply of cold or warm air in rooms with a height between. m and 4 m. They allow easy setting of air deflectors for different modes of operation

Læs mere

WIO200A Water in oil sensor

WIO200A Water in oil sensor WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic

Læs mere

SR20 Cylinder for oil hydraulics

SR20 Cylinder for oil hydraulics SR20 Cylinder for oil hydraulics Dimensions SR20 is a double acting hydraulic cylinder made entirely of stainless steel. Standard cylinder diameters from ø25 mm up to and including ø80 mm. Application

Læs mere

UNISONIC TECHNOLOGIES CO.,

UNISONIC TECHNOLOGIES CO., UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output

Læs mere

laser sensors diffuse reflection sensors 2200 analog signal 4 to 20mA / 0 to 10V 5 external teachable measuring ranges

laser sensors diffuse reflection sensors 2200 analog signal 4 to 20mA / 0 to 10V 5 external teachable measuring ranges diffuse reflection sensors 2200 1 design dif. reflection sensor (spot) dif. reflection sensor (line) 20.4 x 65 x 50mm measuring range 30mm to 1000mm measuring range 30mm to 1000mm measurement independent

Læs mere

VACUUM PRESSURE REGULATOR

VACUUM PRESSURE REGULATOR VUUM PRESSURE REGULTOR DESRIPTION PRESSURE RNGE ONNETION SERIES PGE max. 22 l/min miniature -850 0 mbar 1 8 NPT V800.02 max. 22 l/min miniature -850 0 mbar 10-32 and flange V900.02 max. 0 l/min precise

Læs mere

Precision Dial Gauges. Dial Gauge M 2 T. Dial Gauge MU 52 T. Dial Gauge M 2 X. Dial Gauge M 2 TK.

Precision Dial Gauges. Dial Gauge M 2 T. Dial Gauge MU 52 T. Dial Gauge M 2 X. Dial Gauge M 2 TK. Dial Gauge M 2 T Dial Gauge MU 52 T Dial Gauge M 2 TK Dial Gauge M 2 X Precision Dial Gauges Email: jlouismenegon@aol.com - web: Dial Gauge MU 52 ST Dial Gauge M 2 TOP S Dial Gauge M 3 a S 0.005 mm 5mm

Læs mere

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080) Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Elektrisk aktuator Electric actuator Tekniske data Technical data

Læs mere

AQ70 Cylinder for water hydraulics

AQ70 Cylinder for water hydraulics AQ70 Cylinder for water hydraulics Dimensions AQ70 is a double acting hydraulic cylinder made entirely of stainless materials, designed for tap water as hydraulic fluid. Standard cylinder diameters from

Læs mere

MS-H280-Pro Magnetic Stirrer

MS-H280-Pro Magnetic Stirrer MS-H280-Pro Magnetic Stirrer www..com Copyright: No part of this manual may be reproduced or transmitted without prior written permission of. VERSION201407 CONTENTS Chapter 1: Working Principle... 3 1

Læs mere

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications RAVE The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications Product Presentation RAVE radar motion sensor In addition to the RaDec and RMS product families, the new RAVE radar

Læs mere

Hudevad P5 Easy Clean

Hudevad P5 Easy Clean Technical datasheet Key benefits Rengøring Unique tilting front Radiator front tilts away from the wall for easy access to cleaning the back of the radiator Classic Hudevad design Trademark Hudevad design

Læs mere

Specialprofiler / Special profiles

Specialprofiler / Special profiles EPDM 30.262S 30.WI660 Flere størrelser kan skaffes. Find den komplette liste af firkant/retangulærprofiler på hjemmesiden. Other sizes can be ordered. Find complette list on our homepage. 5 Art. A (mm)

Læs mere

AQ70 Cylinder for water hydraulics

AQ70 Cylinder for water hydraulics AQ70 Cylinder for water hydraulics Dimensions AQ70 is a double acting hydraulic cylinder made entirely of stainless materials, designed for tap water as hydraulic fluid. Standard cylinder diameters from

Læs mere

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support: Industrial flexible rubber cable range with an insulation and sheath in elastomers. Cables for heavy duty uses, Oil resistant and Flame retardancy according to IEC/EN 60332-1-2 standard. BESKRIVELSE Application

Læs mere

Where and why? - How to use welded branches

Where and why? - How to use welded branches O-LETS 1.1.6.1 Where and why? - How to use welded branches Welded Tee 1. Everywhere where welded branches are recommended O-let 2. O-lets replace the welded Tee coasing a reduction of material and labour

Læs mere

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color

Læs mere

WI180C-PB. Online-datablad

WI180C-PB. Online-datablad Online-datablad A B C D E F H I J K L M N O P Q R S T Oversigt over tekniske data Tekniske data Tilbehørsfamilie Henvisning Kapslingsklasse Dimensioner (B x H x L) Beskrivelse Klassifikationer Bestillingsoplysninger

Læs mere

Kignæs hallen. Date: Operator: Projektafdelingen / DANE

Kignæs hallen. Date: Operator: Projektafdelingen / DANE Date: 24.07.2017 Operator: Projektafdelingen / DANE Table of contents Kignæs hallen Project Cover 1 Table of contents 2 FAGERHULT 18453-402 Excis LED bred 4K Luminaire Data Sheet 3 Hal - Nyt anlæg LED

Læs mere

Datamate L-Tek Specification. Pin Numbering DATAMATE L-TEK. Materials. Mechanical. Electrical. Environmental. 5 Female. Female. Male.

Datamate L-Tek Specification. Pin Numbering DATAMATE L-TEK. Materials. Mechanical. Electrical. Environmental. 5 Female. Female. Male. Datamate L-Tek Specification Materials Mouldings: Female contacts: Male contacts: Finish: Electrical Glass-filled thermoplastic UL94V-0 rass shell, with eryllium Copper inner contact Copper alloy See individual

Læs mere

Proportional pressure regulators VEAA

Proportional pressure regulators VEAA Key features Innovative Versatile Reliable Easy to install Silent operation Very low power consumption High precision Integrated piezo technology In-line valves Sub-base valves Simple electrical and pneumatic

Læs mere

TDC 4 Indoor voltage transformers

TDC 4 Indoor voltage transformers Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,

Læs mere

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med

Læs mere

Fundamentals of HVAC Control Systems

Fundamentals of HVAC Control Systems ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 4 Sensors and Auxiliary Devices 2007 ASHRAE Hong

Læs mere

Flow characteristics. 40mm body width 1/4" Ported Flow dm 3 /s Filter 12 Coalescing Filter 2 Regulator 30 Filter Regulator 14 Lubricator 13

Flow characteristics. 40mm body width 1/4 Ported Flow dm 3 /s Filter 12 Coalescing Filter 2 Regulator 30 Filter Regulator 14 Lubricator 13 ( size only) Operating information Working pressure : Plastic bowl: Metal bowl: 10 bar max 17 bar max Working temperature : * Plastic bowl: -10 C to +52 C * Metal bowl: -10 C to +65.5 C * Refer to Technical

Læs mere

AQ70 Cylinder for water hydraulics

AQ70 Cylinder for water hydraulics AQ70 Cylinder for water hydraulics Dimensions AQ70 is a double acting hydraulic cylinder made entirely of stainless materials, designed for tap water as hydraulic fluid. Standard cylinder diameters from

Læs mere

KNIFE GATE VALVE FAF 6500

KNIFE GATE VALVE FAF 6500 PRODUCTION STANDARTS DN50 DN600 PN 10 Connection EN 1092-2 / ISO 7005-2 Face to Face EN 558 Series Marking EN 19 Tests EN 12266-1 Corrosion Protection Electrostatic Powder Epoxy Features y Uni-directional

Læs mere

slicers KRAJALNICE tel /gastroparts.global /gastroparts.global

slicers KRAJALNICE   tel /gastroparts.global /gastroparts.global KRAJANICE www.gastroparts.com gastroparts@gastroparts.com tel. +48 56 657 00 68 /gastroparts.global /gastroparts.global adjustment knobs 1 2 3 symbol 1 697509 0-13 55 4 5 6 7 shaft shaft length handle

Læs mere

High Voltage AC & DC Film Capacitors

High Voltage AC & DC Film Capacitors RoHS COMPLIANT High Voltage AC & DC Film Capacitors Aerovox high voltage capacitors are constructed with metallized polypropylene film and are available in round or oval aluminum cases with four-blade

Læs mere

Newton TS-51. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

Newton TS-51. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO ECO Newton TS-51 Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO Newton Ts-51 Product characteristics Closing force (continuously adjustable) Size acc. to EN Door width acc. to EN 1.100 mm 1 4 459

Læs mere

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Unitel EDI MT940 June 2010 Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Contents 1. Introduction...3 2. General...3 3. Description of the MT940 message...3 3.1.

Læs mere

Farvekoder på vejeceller leveret af NTT fra 2017

Farvekoder på vejeceller leveret af NTT fra 2017 Farvekoder på vejeceller leveret af NTT fra 2017 Betegnelser: Forsyning til vejecellen kan være kaldt +/ -Excitation, Exc., In +/-, Input m.m. Signal fra vejecellen kan betegnes: Signal +/-, out +/-, output

Læs mere

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation PEMS RDE Workshop AVL M.O.V.E Integrative Mobile Vehicle Evaluation NEW - M.O.V.E Mobile Testing Platform Key Requirements for Measuring Systems Robustness Shock / vibrations Change of environment Compact

Læs mere

toolspareparts.com.au

toolspareparts.com.au Page 1 / 9 Page 2 / 9 Page 3 / 9 Parts List 1 JM23100006 CROSS HEAD SCREW M5X20 2 2 JM23100007 FLAT WASHER 5 2 3 JM23100008 PAD 4 4 JM23100009 LOCKNUT M10 1 5 JM23100010 FLAT WASHER 10 2 6 JM23100300 BASE

Læs mere

Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt

Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt Passage 1 Passage 2 Passage 3 Passage 4 Passage 5 27 Bilag 2 Engelsk beskrivelse af S4-måleren InterOcean S4 Current Meter The S4 Electromagnetic

Læs mere

Magnetisk niveauviser

Magnetisk niveauviser Magnetiske niveauviseremagnetisk NIVEAUVISERArbejdstryk op til 16 bar Magnetisk niveauviser Type : MG33 Arbejdstryk op til 16 bar Anvendelse: Niveauvisning og niveaualarm på beholdere, tanke og kedler

Læs mere

SP40G001 40GKX GMC. Split system "Global Cassette" indoor unit. Spare parts 40GKX GKX

SP40G001 40GKX GMC. Split system Global Cassette indoor unit. Spare parts 40GKX GKX SP0G00 0GKX GMC Split system "Global Cassette" indoor unit Spare parts 0GKX 0-08-0 0GKX 08-08-05-060 0GKX 0-08-0 Split system "Global Cassette" indoor unit (Without electric heater) 8 7 9 6 5 0 5 6 7 8

Læs mere

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove Manual Transmission Remove and Install (,0 DOHC 8V Engine) (6 4 0) Workshop Equipment Transmission jack Materials Brake fluid (Super Dot 4) ESD-M6C57-A Remove. Standard preparatory measures: Make a note

Læs mere

Installation Venligst bemærk, håndpumpen kun må monteres i lodret position.

Installation Venligst bemærk, håndpumpen kun må monteres i lodret position. HP-1. HP-3. HP-. Hand Operated Pump Håndpumpe The HP pump is a single acting hand operated pump made of stainless steel St.1.431 making it particularly applicable within the food industry and in environmentally

Læs mere

Lithium-Ion Jump-Starters / Jumper Cables

Lithium-Ion Jump-Starters / Jumper Cables AUTOMOTIVE Lithium-Ion Jump-Starters / Jumper Cables Lithium-Ion Jump-Starter 1300: Part No. DRLJS130 1300 4 6 8 cylinder (6 liter gas 3 liter diesel) SafeJump technology prevents sparking and protects

Læs mere

cylinder cradles. The body is machined from 1 1/2 yellow brass bar stock. Includes proper CGA valves

cylinder cradles. The body is machined from 1 1/2 yellow brass bar stock. Includes proper CGA valves CRADLE PACK MANIFOLDS FOR 6, 12 & 16 CYLINDER SCMB Series cylinder cradles. The body is machined from 1 1/2 yellow brass bar stock. Includes proper CGA valves for high purity and lighter than air gases

Læs mere

Installation Venligst bemærk, håndpumpen kun må monteres i lodret position.

Installation Venligst bemærk, håndpumpen kun må monteres i lodret position. HP-1. HP-3. HP-. Hand Operated Håndpumpe The HP pump is a single acting hand operated pump made of stainless steel St.1.431 making it particularly applicable within the food industry and in environmentally

Læs mere

Metal Oxide Varistor:TVM-B Series

Metal Oxide Varistor:TVM-B Series Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction

Læs mere

BRIEF INFORMATION Generation 2 oil level sensors

BRIEF INFORMATION Generation 2 oil level sensors BRIEF INFORMATION Generation 2 oil level sensors Continual measurement of the engine oil level in the static and dynamic range Compact sensor architecture with a multi-chip module Integrated temperature

Læs mere

Cykelstativ model City

Cykelstativ model City Cykelstativ model City IC 8-2 2 etagers cykelstativ 2 level bicycle rack Design: Inventarrum indoor outdoor SPECIFIKATIONER. SPECIFICATIONS PRODUKTER. PRODUCTS Rammekonstruktion udført i 40 x 40 / 50 x

Læs mere

Translucent multiwall polycarbonate corrugated

Translucent multiwall polycarbonate corrugated Translucent multiwall polycarbonate corrugated 40/3-40/10-40/20 Structural mechanical properties Grecalite 40/3-10-20 sheeting comes in excellent, practical shapes and sizes, designed to meet the The complementary

Læs mere

COMPLETE ENGINE PARTS LIST

COMPLETE ENGINE PARTS LIST COMPLETE ENGINE PARTS LIST for CRF50F Please confirm engine spec. CODE NO, TRANSMISSION GENERATOR 3a CH-200-1129301 NO-IGNITION TYPE 3b CH-200-1129302 3 SPEED CLOSED TRANSMISSION INNER ROTOR KIT TYPE-1

Læs mere

MJB-A. Posefilter. Egnet til explosivt støv Metode for filterrensning

MJB-A. Posefilter. Egnet til explosivt støv Metode for filterrensning Posefilter omfatter en serie robuste alsidige filterenheder, som bygger på erfaringerne fra MJB posefilteret. Ved at kombinere to-trins rensning med den patenterede UniClean teknologi, opnås maksimal renseeffektivitet

Læs mere

CYLINDRE MED SKRABERING - UNDGÅ SNAVS PÅ STEMPELSTANGEN

CYLINDRE MED SKRABERING - UNDGÅ SNAVS PÅ STEMPELSTANGEN R // INDUSTRIENS EDSTE SAMAREJDSPARTNER CYLINDRE MED SKRAERING - UNDGÅ SNAVS PÅ STEMPELSTANGEN Nedbrud Snavs Støv Tilstopning EN HOLDARHED UD OVER DET SÆDVANLIGE Vi har en serie af komponenter, der er

Læs mere

Modell nr. LS1018L 260MM SLIDE COMPOUND MITER SAW

Modell nr. LS1018L 260MM SLIDE COMPOUND MITER SAW Sida 1 / 3 Sida 2 / 3 Sida 3 / 3 Sida 1 / 7 001 JM23100006 CROSS HEAD SCREW M5X20 2 002 JM23100007 FLAT WASHER 5 2 003 JM23100008 PAD 4 004 JM23100009 LOCKNUT M10 1 005 JM23100010 FLAT WASHER 10 2 006

Læs mere

Skidding System. Challenge Us

Skidding System. Challenge Us Skidding System n Malm Orstads cutting edge Engineering department designs and fabricates tailor made skidding systems for all kinds of enviroments. Our skidding systems are amongst the most efficient

Læs mere

BroadLite LED FLOOD LIGHT FIXTURE

BroadLite LED FLOOD LIGHT FIXTURE BroadLite - 277 V Standard; 347-480 V option available 10 year warranty Chip-scale package LEDs 0-10 V dimming standard; DALI dimming option available C 136.41 compliant rotating photocell receptacle Corrosion

Læs mere

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Constant Terminal Voltage. Industry Workshop 1 st November 2013 Constant Terminal Voltage Industry Workshop 1 st November 2013 Covering; Reactive Power & Voltage Requirements for Synchronous Generators and how the requirements are delivered Other countries - A different

Læs mere

Modulerende kuglehane

Modulerende kuglehane 690 Modulerende kuglehane Cim 690 Modulerende kugleventil Cim 690 kuglehane er en modulerende ventil på grund af venturi boring som gør det muligt at op linear eller logaritmisk flow. Cim 690 kuglehaner

Læs mere

frame bracket Ford & Dodge

frame bracket Ford & Dodge , Rev 3 02/19 frame bracket 8552005 Ford & Dodge ITEM PART # QTY DESCRIPTION 1 00083 8 NUT,.50NC HEX 2 00084 8 WASHER,.50 LOCK 3 14189-76 2 FRAME BRACKET 4 14194-76 1 411AL FRAME BRACKET PASSENGER SIDE

Læs mere

MJB-G. Posefilter. Egnet til explosivt støv Metode for filterrensning

MJB-G. Posefilter. Egnet til explosivt støv Metode for filterrensning Posefilter omfatter en serie robuste alsidige filterenheder, som bygger på erfaringerne fra MJB posefilteret. Ved at kombinere to-trins rensning med den patenterede UniClean teknologi, opnås maksimal renseeffektivitet

Læs mere

Diamond Core Drilling

Diamond Core Drilling Diamond Core Drill ZIZ-250Pro Product Description Diamond core drill is a tool used for drilling holes on reinforced concrete, rocks and fire-proof materials. It features in high-efficiency, smooth and

Læs mere

ZB4BG2 Nøglegreb 2 positioner fast ud: V n G

ZB4BG2 Nøglegreb 2 positioner fast ud: V n G Produkt datablad Karakteristika ZB4BG2 Nøglegreb 2 positioner fast ud: V n G Primær Produktsortiment Harmony XB4 Produkttype Head for key selector switch Enhedens korte navn ZB4 Frontringsmateriale Chromium

Læs mere

Small Autonomous Devices in civil Engineering. Uses and requirements. By Peter H. Møller Rambøll

Small Autonomous Devices in civil Engineering. Uses and requirements. By Peter H. Møller Rambøll Small Autonomous Devices in civil Engineering Uses and requirements By Peter H. Møller Rambøll BACKGROUND My Background 20+ years within evaluation of condition and renovation of concrete structures Last

Læs mere

DOL 15 SENSOR. DA Teknisk brugervejledning. EN Technical user s guide. DE Technisches Bedienungsanleitung.

DOL 15 SENSOR. DA Teknisk brugervejledning. EN Technical user s guide. DE Technisches Bedienungsanleitung. DOL 15 SENSOR DA Teknisk brugervejledning EN Technical user s guide DE Technisches Bedienungsanleitung www.dol-sensors.com DA TEKNISK BRUGERVEJLEDNING 1 Produktbeskrivelse DOL 15 er en universel fuldelektronisk

Læs mere

Engine Powered Forklift ton

Engine Powered Forklift ton Engine Powered Forklift 1. - 7.0 ton 8FGCU1-30 8FGC3U-70U www.toyota-forklifts. Engine Powered Forklift 1. - 1.7 tonne Truck specifications 8FGCU1 8FGCU18 1.1 Manufacturer TOYOTA TOYOTA 1.2 Model 8FGCU1

Læs mere

Linear drive units DGO

Linear drive units DGO Features General information Double-acting Magnetically coupled without mechanical connections Piston chamber and slide are pressure tight Pressure tight and leak-free system Dirt and dust cannot enter

Læs mere

OG-3600 Series Fiber Optic Transport for opengear card frame platform w/ SNMP Management

OG-3600 Series Fiber Optic Transport for opengear card frame platform w/ SNMP Management FEATURES w w 4 HDSDI 3G 8x8 Line/AES Genlock Time Code, GPIO, Data APPLICATIONS Studio Links Signal Trunking Signal distribution Campus interconnects Transmission links Telco circuits w w Outside Broadcast

Læs mere

DOOR TECHNOLOGY - ORDER CATALOG. Lift&Slide Hardware

DOOR TECHNOLOGY - ORDER CATALOG. Lift&Slide Hardware DOOR TECHNOLOGY - ORDER CATALOG Lift&Slide Hardware Door Lift&Slide Multipoint Hardware Locking System Solid Product brass Information handle & 45mm plate series Application Range of applications for

Læs mere

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package High Speed LDO Regulators, High PSRR, Low noise, Series General Description The series are highly accurate, low noise, CMOS LDO Voltage Regulators. Offering low output noise, high ripple rejection ratio,

Læs mere

BADGES CATALOG d e s i g n p r o d u c e d e l i v e r

BADGES CATALOG d e s i g n p r o d u c e d e l i v e r BADGES CATALOG design produce deliver BADGES Your company name, brand or marketing activity on a professional personalized badge or pin. Sharp full color print, also available with a providing high-end

Læs mere

Docubind TL350 EURO. Ersatzteilkatalog Spare parts catalogue Catalogue des pièces détachées Catálogo de peças

Docubind TL350 EURO. Ersatzteilkatalog Spare parts catalogue Catalogue des pièces détachées Catálogo de peças Docubind TL350 EURO Edition Serial No. Date Name 1 QJP0012- November 2004 GBC Portuguesa Ersatzteilkatalog Spare parts catalogue Catalogue des pièces détachées Catálogo de peças Version Product No. Docubind

Læs mere

3.2.1 SKUEGLAS / SIGHT GLASS

3.2.1 SKUEGLAS / SIGHT GLASS , Metalstøbte skueglas, DIN 7079 /, Metal Fused Sight glass, DIN 7079 Materiale: 1.4462 i h.t. VdTÜV specifikation & DIN/EN standard / Material: 1.4462 acc. to VdTÜV specifications & DIN/EN standards Glas:

Læs mere

User Manual for LTC IGNOU

User Manual for LTC IGNOU User Manual for LTC IGNOU 1 LTC (Leave Travel Concession) Navigation: Portal Launch HCM Application Self Service LTC Self Service 1. LTC Advance/Intimation Navigation: Launch HCM Application Self Service

Læs mere

PRODUKTARK FOR VV xxxx Alfa laval varmevekslere

PRODUKTARK FOR VV xxxx Alfa laval varmevekslere PRODUKTARK FOR VV xxxx Alfa laval varmevekslere 27/6 2013 MFJ Alcon sælger et stort udvalg af Alfa Lavals varmevekslere Nedenfor her følger en kort beskrivelse af de mest gængse modeller Varenr Beskrivelse

Læs mere

Navn: DVG V 450EC/F400 varenr.: 95257

Navn: DVG V 450EC/F400 varenr.: 95257 DVG-V 450EC/F400 varenr. 95257 Document type: Product card Document date: 2012-11-08 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

BioLite NET Innovative Fingerprint Terminal

BioLite NET Innovative Fingerprint Terminal www.supremainc.com BioLite NET Innovative Fingerprint Terminal User Guide User guide( (ver 1.0 ) 1.0) Product Contents Basic Contents Product Contents E-ring Main Body Default Sub bracket (optional) Wall-mounting

Læs mere

Rustfri kæde og tilbehør. Stainless Chain and Accessories. Indhold. Connex Chainlock CK

Rustfri kæde og tilbehør. Stainless Chain and Accessories. Indhold. Connex Chainlock CK kæde og tilbehør Indhold Kæde DIN 5685C Kæde DIN 766A Kæder og komponenter Nødled Pladelås BG-SS bøjlewirelås karabinhage kovs kædesling masterlinks Chain and Accessories Index Chain DIN 5685C Chain DIN

Læs mere

ZB5AG6 Nøglegreb Ø22 2 positioner med ret til V UD:V n G

ZB5AG6 Nøglegreb Ø22 2 positioner med ret til V UD:V n G Produkt datablad Karakteristika ZB5AG6 Nøglegreb Ø22 2 positioner med ret til V UD:V n G Alternativ Bredde Højde Dybde Vægt Mekanisk holdbarhed Stationsnavn Elektrisk composition kode Bestillingsmåde Miljø

Læs mere

YDEEVNEDEKLARATION nr. IG10015

YDEEVNEDEKLARATION nr. IG10015 YDEEVNEDEKLARATION nr. IG10015 1. Byggevaretype: Faste lodrette trafikskilte 2. Byggevareidentifikation: Rørgalger med monterede færdselstavler 3. Byggevarens tilsigtede anvendelse: Stationære, vertikale

Læs mere

More Precision. capancdt MD6-22 // Mobile gap gauge

More Precision. capancdt MD6-22 // Mobile gap gauge More Precision capancdt MD6-22 // Mobile gap gauge Capacitive gap gauge capancdt MD6-22 - High-precision gap measurement - Intuitive operation - For electrically conductive measurement objects - Comprehensive

Læs mere

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Agenda Electromagnetic Compatibility (EMC) Application of Cable Ferrites Impedance

Læs mere

highline med ramme with frame mit rahmen

highline med ramme with frame mit rahmen highline med ramme with frame mit rahmen Hvad er HighLine med ramme? HighLine med ramme er en produktserie bygget omkring det velkendte unidrain system. Udløbshuset og afløbsarmaturet er de samme produkter:

Læs mere

DEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark.

DEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark. CERTIFICATE Issued to: Applicant: ALIT S.r.l. ia Padania 6 20853 Biassono (MB) - ITALY Manufacturer/Licensee: ALIT S.r.l. ia Padania 6 20853 Biassono (MB) - ITALY Product(s) : Electronic controlgear for

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK). DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

Navn: DVG V 560EC/F400 varenr.: 95135

Navn: DVG V 560EC/F400 varenr.: 95135 DVG-V 560EC/F400 varenr. 95135 Document type: Product card Document date: 2012-11-08 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

how to save excel as pdf

how to save excel as pdf 1 how to save excel as pdf This guide will show you how to save your Excel workbook as PDF files. Before you do so, you may want to copy several sheets from several documents into one document. To do so,

Læs mere

Exploded View Parts List

Exploded View Parts List Exploded View Parts List Valid Units VCBA118-37 VCBA128-37 VCBA168-37 1 2 ITEM STOELTING PART NUMBER STOELTING DESCRIPTION 1 BR0149 COVER W/MAGNET - TOP 2 BR0150 SCREEN TOP INNER 3 4 BR0151 SCREEN TOP

Læs mere

Proportional pressure regulators VEAB

Proportional pressure regulators VEAB Proportional pressure regulators VEAB Key features Innovative Versatile Reliable Easy to install Silent operation Very low power consumption High precision Short switching times Piezo technology In-line

Læs mere

JM-3080 PARTS LIST. Jet-Set JM-3080

JM-3080 PARTS LIST. Jet-Set JM-3080 JM-3080 PARTS LIST ITEM DESCRIPTION PART # QTY ITEM DESCRIPTION PART # QTY DECAL - JM-3080 FRONT 1 PANEL N/A 1 46 BALL VALVE JM22-0494 1 (SEE JM71-0004) 47 HANDLE GRIP JM7-0227 1 2 BOLT JM27-0066 10 48

Læs mere

CERTIFIKAT CERTIFICATE

CERTIFIKAT CERTIFICATE CERTIFIKAT CERTIFICATE Dette certifikat er udstedt i henhold til bekendtgørelse nr. 1007 af 29. juni 2016 om markedsføring og salg af byggevarer i kontakt med drikkevand. Certifikatet giver godkendelsesindehaveren

Læs mere

Index for chapter 10. Hooks f.pegboards and slatpanels double/single and accessories Page

Index for chapter 10. Hooks f.pegboards and slatpanels double/single and accessories Page Displays 10.0 December 1999 Index for chapter 10. Hooks f.pegboards and slatpanels double/single and accessories Page 10.1 10.4 Brochure display curved and and accessories Page 10.5 Uni-frames and accessories

Læs mere

www.svovlbrinte.dk MeasureStar Hjælp til beskyttelse af dit kloaksystem

www.svovlbrinte.dk MeasureStar Hjælp til beskyttelse af dit kloaksystem MeasureStar Hjælp til beskyttelse af dit kloaksystem H 2 S Problem i kloaksystemet Produktionen og frigivelsen H 2 S gas i spildevandsystemer er ansvarlig for mange klager over lugt. Dog er destruktionen

Læs mere

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet.

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet. ATEX direktivet Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet.dk tlf: 7220 2693 Vedligeholdelse af Certifikater / tekniske dossier / overensstemmelseserklæringen.

Læs mere

ZB4BD5 Drejegreb 3 positioner med retur til M

ZB4BD5 Drejegreb 3 positioner med retur til M Produkt datablad Karakteristika ZB4BD5 Drejegreb 3 positioner med retur til M Primær Produktsortiment Harmony XB4 Produkttype Hoved for selektor kontakt Enhedens korte navn ZB4 Frontringsmateriale Chromium

Læs mere

DAY HUNTER KIT ASSEMBLY INSTRUCTIONS

DAY HUNTER KIT ASSEMBLY INSTRUCTIONS DAY HUNTER KIT ASSEMBLY INSTRUCTIONS Attach the Shoulder Harness to the Frame 1. Pass the Upper Harness Attachment Straps (Diagram 1.) through the attachment points located inboard on the upper portion

Læs mere

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

Portal Registration. Check Junk Mail for activation  . 1 Click the hyperlink to take you back to the portal to confirm your registration Portal Registration Step 1 Provide the necessary information to create your user. Note: First Name, Last Name and Email have to match exactly to your profile in the Membership system. Step 2 Click on the

Læs mere

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA TekVor 1300C 1. Before You Begin This guide provides basic guidelines to assist you in quickly getting started. Installation of the transmitter in an explosive environment must be in accordance with the

Læs mere

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator Opera Ins Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator I.Precautions 1. Keep the product away from children to avoid children playing it as a toy and resultinginpersonalinjury.

Læs mere