1 Korrosion af rustfrit stål i svømmehalsmiljø Ebbe Rislund og Jesper N. Holst FORCE Technology Park Alle Brøndby
2 Abstract Stainless steel has for many years been used in indoor swimming pools for various details like ladders, starting blocks, drain covers and pool water tubing. Grade 316 has been the standard material for these applications. During the recent years the use of stainless steel has been extended to areas like pool lining, support of ventilation ducts and ceiling hangers as well as hangers and wires for lamps and loudspeakers. A number of incidents, some of which having resulted in injuries, have shown that stress corrosion cracking (SCC) in austenitic stainless steels is a real risk in indoor swimming pool atmosphere. The SCC is caused by the corrosive, chloride-containing environment formed on the surface of the stainless steel by contamination from pool water aerosols and influence of chloramines in the hall atmosphere. SCC may result in sudden fracture of the stainless steel and thus present a risk of injury. The influence of the environment parameters on the risk of SCC is discussed. Due to the fact that the risk of stress corrosion cracking can only be eliminated by the use of the highest alloyed stainless steel grades, the solution of the problem is usually the use of alternative materials like some kind of coated steel. Abstrakt Rustfrit stål har i mange år været anvendt i svømmehaller til forskellige komponenter som lejdere, startskamler, afløbsriste og rør til bassinvand. AISI 316 har været standardmaterialet til disse anvendelser. I de senere år er anvendelsen af rustfrit stål blevet udvidet til områder som foring af bassin, ophæng til ventilationskanaler og lofter såvel som ophæng og wirer til lysarmaturer og højttalere. Et antal ulykker, hvoraf nogle har resulteret i kvæstede personer og dødsfald, har vist, at spændingskorrosion af austenitiske rustfri stål er en reel risiko i svømmehalsatmosfære. Spændingskorrosionen skyldes det korrosive kloridholdige miljø, der dannes på det rustfrie ståls overflade ved forurening fra aerosoler af bassinvand og indflydelse fra kloraminer i halatmosfæren. Spændingskorrosionen kan resultere i pludselige brud på det rustfrie stål og frembyder derved en risiko for nedstyrtning. Indflydelsen af miljøparametre på spændingskorrosionsrisikoen diskuteres. På grund af at spændingskorrosionsrisikoen kun kan fjernes ved anvendelse af de højest legerede rustfrie stål er løsningen på problemet normalt anvendelse af alternative materialer som coatede stål. EBR/JQH-2
3 Indledning Rustfrit stål har været anvendt til komponenter i svømmehaller i årtier. Baggrunden er, at rustfrit stål med sin blanke og generelt bestandige overflade signalerer hygiejne og renlighed. Det kan holde sig blankt og fri for korrosionsprodukter i endog meget fugtige miljøer, og det er tolerant overfor en række ganske forskelligartede rengøringsmidler. Den traditionelle anvendelse har været til lejdere, startskamler og andet udstyr omkring bassinet samt afløbsriste og andet inventar, der kan blive vådt herunder f. eks. borde og vaske. I de sidste 20 år er rustfrit stål også blevet anvendt til andre dele i svømmehalsbygninger. Her kommer rustfri lining af bassiner ind i billedet, og ophæng til ventilationskanaler, lofter, højttalere og armaturer. Også ventilationskanaler er blevet udført i rustfrit stål. I badearealerne er der også kommet gelændere udført i rustfrit stål alt sammen for at underbygge et rent look og med tanke på minimalt vedligehold. I de seneste år, er der så sket en drejning af svømmehallers indretning og anvendelse. Fra at være anlæg med firkantede bassiner, hvor de badende svømmede rundt i et roligt tempo, er ikke mindst nye svømmehaller gradvist blevet forvandlet til rekreative vandlande, med vandrutschebaner, fontæner, kunstigt regnvejr og varmtvandsbassiner eventuelt suppleret med bølgemaskiner. Også temperaturniveauet i hallerne er også steget fra tidligere til det nuværende niveau nær 30 C. Denne ændring har påvirket miljøet i hallerne i retning af, at større korrosionsbelastning af det rustfrie stål i hallerne, hvilket ført til stadig flere korrosionsskader på rustfrit stål, og har gjort, at der bør tænkes nyt, når det drejer sig om at undgå problemer med rustfrit stål i svømmehaller. Nedenfor behandles korrosionsforholdene for rustfrit stål i svømmehaller. Rustfri ståltyper. Traditionelt har det i høj grad været de austenitiske ståltyper, der har været og fortsat er anvendt i svømmehaller. Tabel 1 viser en række stålkvaliteter, der anvendes i hallerne. De fleste er typisk austenitiske, men der kan også forekomme enkelte komponenter af ferritisk stål. Ståltype struktur C% Cr% Ni% Mo% AISI 430 (EN ) ferritisk < 0,12 17 AISI 301 (EN ) austenitisk < 0, AISI 304 EN austenitisk < 0, AISI 316 EN austenitisk < 0, ,2 UNS EN austenitisk < 0, ,1 Tabel 1. Rustfrie ståltyper anvendt i svømmehaller. EBR/JQH-3
4 Korrosionsmiljøer Der er to områder, hvor rustfrit stål bliver anvendt i hallerne. I bassinerne er stålet neddykket i svømmevandet, og korrosionsforholdene bestemt heraf. I hallen og bygningen er det rustfri stål udsat for den aktuelle atmosfære. Da de to miljøer er væsensforskellige vil disse blive behandlet hver for sig. Bassinvand. Bassinvandet i en svømmehal er som oftest brugsvand med de tilhørende salte som i grove træk er hårdhedsdannere (calcium, magnesium, bicarbonat) samt anionerne klorid og sulfat. Hertil er ofte sat natriumklorid i en mængde svarende til 0,3-0,4% klorid, i forbindelse med klorgenerering. Til dette vand sættes desinfektionsmiddel som regel i form af aktivt klor doseret som natriumhypoklorit eller som klor genereret direkte i vandet ved elektrolyse. Temperaturen er som regel C. Det korrosionsmiljø, som bassinkomponenter i rustfrit stål skal modstå, er således en lun vandig opløsning med et kloridindhold op til 0,4% med en ph-værdi på godt 7. I et sådant miljø er det lokalkorrosion, der er den levetidsbegrænsende korrosionsform. Det er altså grubetæring eller spaltekorrosion lokalkorrosion som en fællesbetegnelse som de rustfrie stål skal være bestandige overfor og altså på det grundlag, det aktuelle materiale skal vælges. Nu er det jo sådan, at de parametre, der sætter grænserne for lokalkorrosion af rustfrit stål er temperatur, kloridindhold og korrosionspotential. De er i princippet komplementære således at jo højere hver enkelt af de tre parametre er, jo mindre bliver tolerancen overfor de to andre før lokalkorrosionen indtræder. At de to lokalkorrosionsformer er det spaltekorrosionen, der indtræder først, og når denne er initieret, vil stålet være beskyttet mod grubetæring, fordi korrosionspotentialet bliver holdt nede af den aktive spaltekorrosion. Derfor er det næsten udelukkende spaltekorrosionsskader, man oplever på bassinkomponenter, såfremt der overhovedet er spalter til stede. Det er der som regel i forbindelse med lejdere og trapper, hvor disse er fastgjort til bassinet under vandoverfladen. Hvor kritisk en geometri spalterne har, afhænger først og fremmest af, hvor godt det er lykkedes at forsegle spalterne op mod bassinets væg eller bund. Herudover kan man betragte den rustfrie ståloverflades finish som en parameter. Jo mere glat en overflade er des mindre er risikoen for at der starter lokalkorrosion på den. På den baggrund er det ikke overraskende, at blankt bassinudstyr klarer sig rimeligt godt. I forhold til almindeligt brugsvand er svømmevand som nævnt karakteriseret ved, at kloridindholdet er højere. Desinfektionen med klortilsætning kan også være en skærpende faktor, EBR/JQH-4
5 idet stålets korrosionspotential kan blive hævet afhængigt af restkoncentrationen af aktivt klor i vandet. Normalt vil korrosionspotentialet i vand med det aktuelle saltindhold have et korrosionspotential på omkring 0 mv SCE. Fra klorering af havvand ved man, at et restklorindhold over 0,2 ppm resulterer i et korrosionspotential på ca. 700 mv SCE på grund af klorets oxiderende virkning. Da klorniveauet sjældent er under de 0,2 ppm er der mulighed for en dramatisk stigning i korrosionspotentialet ved klortilsætning og således mulighed for at øge korrosiviteten betydeligt. Hvor stor tolerancen er, afhænger naturligvis af den anvendte stålkvalitet, men der kendes tilfælde af korrosion, der har haft årsag i en særlig høj dosering af aktivt klor fordi styringen af tilsætningen har været i uorden. Der er en langvarig tradition for at anvende syrefast stål (AISI 316, EN ) til bassinudstyr og i en vis udstrækning rørsystemer. Det klarer sig da også rimeligt, men det forudsætter, at kloroverskuddet ikke er ret stort. Nyere anlæg, herunder anlæg med bassiner foret med rustfrit stål eller udstyret med skvulperender af rustfrit stål, kan være udstyret med stål af typen EN , (6% molybdæn), som hører til de mest bestandige rustfrie ståltyper. Halatmosfære. Atmosfæren i en svømmehal er i princippet atmosfærisk luft med en vis naturlig fugtighed. Tidligere havde man betydelige problemer med meget høj luftfugtighed, men i moderne svømmehaller, der jo er udstyret med avancerede klimaanlæg, styrer man normalt luftfugtigheden til mellem 50-65% relativ fugtighed. Dette gøres i det væsentlige ved at tilføre friskluft i det nødvendige omfang, men ellers er klimaanlæggets væsentligste funktion at opnå komfort ved hjælp af mindst mulig energitilførsel. På denne baggrund synes det uproblematisk at få rustfrit stål til at holde i halatmosfæren med en moderat luftfugtighed. Så enkelt er det imidlertid ikke, idet der er flere kilder til forurening af den rustfri overflade med klorider, som jo er en af de mest korrosive komponenter for rustfrit stål. Flere forskere (1, 2) har fundet, at der ofte er de samme ioner tilstede på de rustfri stål overflader i atmosfæren, som man finder i vandet. Det tages som bevis for, at der i hallen dannes aerosoler af badevand, som transporterer salte hen til de rustfri overflader langt væk fra bassinet, for eksempel oppe under loftet. På denne måde forurenes overfladerne med klorid og andet på steder, hvor de ikke bliver løbende rengjort, og hvor koncentrationen med tiden kan blive så stor, at korrosion indtræder. Hvis man forestiller sig, at der initieres lokalkorrosion på rustfri overflader som følge af kloridforurening, vil det før eller senere føre til, at der lokalt i aktive gruber genereres et ganske stærkt surt miljø med høj kloridkoncentration, som er korrosivt for stålet, og som eventuelt kan føre til spændingskorrosion på det rustfrie stål selv ved rumtemperatur, hvis det fornødne spændingsniveau er til stede. EBR/JQH-5
6 En anden mulighed for forurening af rustfri overflader med klorholdige forbindelser stammer fra desinfektionen af bassinvandet med klor. Aktivt klor danner ved reaktion med kvælstofholdige kropsvæsker kloraminer, som således vil være tilstede i bassinvandet. Da kloraminerne er flygtige, kan de forlade vandet og overgå til atmosfæren. Det er kloraminer, der giver den karakteristiske svømmehalslugt. Når kloramin kommer i kontakt med det rustfrie stål, anses det at gå i stykker efter ligningen: NCl 3 +3H 2 0 3HCl + 3HClO + N 2 Ovennævnte er et eksempel baseret på den mest flygtige kloramin og altså den, der er mest sandsynlig i halatmosfæren, men de øvrige giver i princippet samme produkter. Af ligningen ses, at kloramin spaltes til saltsyre og hypoklorit ved kontakten med stålet. Det betyder, at de to forbindelser, der begge er korrosive for rustfrie stål, dannes direkte på overfladen, hvor de bidrager til at generere et surt, kloridholdigt miljø. Saltsyren må antages at reagere forholdsvis hurtigt med stålet, hvilket giver anledning til, at der dannes metalklorider (jern- krom-) på overfladen ved siden af de klorider, der måtte komme fra bassinet. Resultatet er, at der bliver en korrosiv belastning på stålet, hvis det ikke løbende rengøres, så kloriderne fjernes i den takt de dannes. For udstyr indenfor bassinområdet vil den daglige rengøring fjerne kloriderne, så der ikke sker korrosion, men hvis det ikke sker, f. eksempel under startskamler, kan man observere dannelse af rust. Men det kan gå værre endnu. Figur 1 viser et brugsvandsrør af AISI 304, der har siddet i et bruserum tæt på indgangen til svømmehallen, og som er gennemtæret udefra som følge af atmosfæren fra hallen. At der er kloridforurening på overfladen af rustfrit stål i svømmehaller har vi på FORCE konstateret i forbindelse med undersøgelse af korrosionsskader i svømmehaller, men også på Korrosionsinstituttet i Sverige har man beskæftiget sig med kloridniveauet (3). Tabel 2 viser en sammenstilling af fundne kloridniveauer på forskellige komponenter. Det ses, at der er stor spredning i de målte koncentrationer afhængigt af, hvor de er målt, men generelt er det meget høje koncentrationer. Til sammenligning kan nævnes, at kloridniveauet i en dagligstue er ~5 µg/cm² og en kraftig påvirkning fra saltsyreholdig røg i forbindelse med brand resulterer normalt i µg/cm².. Det ses også af de to nederste tal i tabellen, at forureningen falder kraftigt, så snart man bevæger sig uden for selve svømmehallen. EBR/JQH-6
7 A B C D Figur 1. Brugsvandsrør gennemtæret udefra som følge af kloridforurening fra svømmehallen. a. viser røret, der forløber under loftet og forsyner bruserne i baggrunden. Det ses, at der hvor røret bliver dagligt rengjort er der ingen korrosion. b. viser et rørstykke med to gennemtæringer. c. viser et nærbillede af røret med overfladiske grubetæringer. d. viser en gennemtæring udefra gennem rørets svejsning. Overflade Klorid µg/cm² Vandrutschebane, bolte og møtrikker Rustfrit loftophæng Rustfrit lampeophæng Befæstelse spotlampe 857 Rustfri ramme i glasparti 150 Loftophæng, sluse til svømmehal Loftophæng, bruserum 3 Tabel 2. Målte kloridkoncentrationer EBR/JQH-7
8 Selv om materialet er beskedent, har vi fundet en vis sammenhæng mellem koncentrationen af klorid på de rustfri overflader og koncentrationen af kloramin i halatmosfæren, hvilket peger på, at kloraminerne spiller en mærkbar rolle for kloridforureningen af det rustfrie stål. Spændingskorrosion er det største og farligste problem I 1985 skete en tragisk ulykke i en svømmehal i Uster i Schweiz, Uden varsel kollapsede tagkonstruktionen og loftet faldt ned. Da hallen var åben for besøgende, blev 13 mennesker dræbt (2). Den efterfølgende udredning af uheldet viste, at årsagen til nedstyrtningen var transkrystallinsk spændingskorrosion i loftets ophæng, der var lavet af rustfrit stål AISI 316. Denne erfaring var ganske ny. Det var kendt, at spændingskorrosion kunne opstå i denne legeringstype, men det var en håndregel, at det kun kunne foregå over 60 C og temperaturen i hallen var ikke over 30 C. Tilfældet førte til ret omfattende udrednings- og forskningsaktivitet, hvilket førte blandt andet frem til følgende konklusion: 1. Spændingskorrosion kan opstå i AISI 316 ved lav temperatur hvis ph er lav (~1,5) 2. Kloraminer er en sandsynlig kilde til overførsel af klorholdige forbindelser til den rustfri overflade. 3. Spændingskorrosion opstår mest sandsynligt ved luftfugtigheder i området 30-35% relativ fugtighed. Efter en årrække med forskningsaktiviteter, hvor viden om kloridkilder og overførsel til det rustfrie stål blev yderligere udbygget og belyst, kom næste ubehagelige overraskelse. I 2001 brød ophængene til ventilationskanalerne sammen i en svømmehal i Steenwijk i Holland (4). Kanalerne faldt ned og tog hele loftet med. Figur 2 viser svømmehallen efter ulykken. Heldigvis skete ulykken om natten, så der ikke kom mennesker til skade, men den viste, at problemet stadig er aktuelt at tage stilling til, og hvad man måtte have lært af Usterulykken, var der altså nogle, der ikke havde fået at vide. EBR/JQH-8
9 Figur 2. Svømmehallen i Steenwijk morgenen efter ulykken. Efter Steenwijk-ulykken blev der meget opmærksomhed omkring problematikken, ikke mindst i Holland, hvor man indførte regelmæssig inspektion af svømmehaller for at forebygge gentagelser. Denne inspektion har vist sig at være nødvendigt, idet der med mellemrum findes usikre konstruktioner. Alene i 2005 er der blevet lukket tre svømmehallen efter inspektion fordi der blev fundet spændingskorrosion i bærende ophæng for lofter og ventilationskanaler. I Danmark har vi haft en række tilfælde af bærende komponenter i svømmehaller, hvor der er blevet fundet spændingskorrosion i rustfrit stål. Ved vintermødet i 2004 præsenterede Jesper Holst en undersøgelse af spændingskorroderede rustfri skruer til befæstigelse af loftsplader (5). Også wirer til ophæng af forskellige komponenter herunder wirer og wirelåse til ophæng af akustiske baffleplader har der været problemer med. Figur 3 viser spændingskorrosionsskaderne på wirelås og wire. På wirelåsen ses der tydeligt spændingskorrosion på brudfladen, medens der kan ses små spændingskorrosionsrevner på de enkelte tråde i wiren. EBR/JQH-9
10 Figur 3. Spændingskorrosion på wirelås (øverst) og wire af AISI 316 til ophæng af baffleplader i svømmehal. I det seneste år er der konstateret spændingskorrosion i ophæng til lofterne i to svømmehaller efter 1 1½ års drift, og som har ført til omgående udskiftning af ophængene. Det er standardophæng, de såkaldte hurtigophæng, der har været anvendt til formålet, og som også har givet problemer andre steder i Europa. De er karakteriseret ved, at længden kan justeres på stedet, så loftet kan justeres præcist. Men de er også karakteriseret ved, at spændingsniveauet i låseclampen er meget højt, hvilket er en af forudsætningerne for dannelse af spændingskorrosion. Clampen er fremstillet i AISI 301, der, som det ses af tabel 1, er et austenitisk stål med lavere legeringsniveau end AISI 304 og altså også med mindre korrosionsbestandighed, medens trådene er i AISI 430. Figur 4 viser eksempler på korrosion i sådanne hurtigophæng. Det ses, at låseclampene er angrebet af spændingskorrosion, samt at revnedannelserne hurtigt kan føre til, at clampen mister sin låsefunktion og dermed resulterer i, at ophænget mister sin bæreevne. Trådene er noget angrebet af grubetæring, men fri for spændingskorrosion, da de er udført i ferritisk stål. Clampene er fra fremstillingen kraftigt kolddeformeret. De har derfor har et højt egenspændingsniveau, men dertil kommer yderligere spændinger fra deres funktion, hvor låsefunktionen også kræver tilstedeværelse af spændinger. Der er således spændinger nok til rådighed for initiering af spændingskorrosion, når miljøforholdene er de rigtige. EBR/JQH-10
11 Figur 4. Rustfri loftsophæng efter 1-1½ år over svømmehal. Spændingskorrosion har ødelagt låseclampene. Det blev ovenfor nævnt, at spændingskorrosion havde lettest ved at opstå ved luftfugtigheder i området 30-35% relativ fugtighed. Hvordan kan det så gå til, at der opstår spændingskorrosion i svømmehaller, hvor luftfugtigheden styres i området 50-65% RF? At spændingskorrosionen kan opstå, selv om luftfugtigheden tilsyneladende er meget højere, skal ses på den baggrund, at en lokal opvarmning på 7-9 C vil resultere i, at luftfugtigheden falder til netop 30-35%, som anses for det mest kritiske interval. Ved katastrofen i Uster er det fastslået, at temperaturen over loftet var omkring 40 C, hvilket gav baggrund for de lave fugtigheder. I det ovenfor nævnte tilfælde med de spændingskorroderede wirer, var der kun skader på de wirer, der var tæt på en mørk ydervæg, der kunne modtage kraftigt solindfald i løbet af dagen (sydøst-syd-sydvest) altså i et område, hvor der kunne herske en betydelig lokal overtemperatur. De øvrige fejlede ingenting. Ved tilfældene i de nye haller har det ikke været muligt fuldt at dokumentere den nødvendige overtemperatur over lofterne, hvilket imidlertid ikke udelukker, at den kan have været til stede. Hvad man derimod ved er, at der i begge haller i begyndelsen har været betydelige gener fra, hvad man anser for høje kloraminkoncentrationer, indtil man fik ændret på ventilationsanlæggenes kapacitet. Så her har der under alle omstændigheder været mulighed for en ekstraordinær korrosiv påvirkning af loftophængene i en periode. EBR/JQH-11
12 Hvad er forklaringen på, at det netop er ved de lave fugtigheder, at sandsynligheden for spændingskorrosion er størst? Generelt set er det sådan, at risiko for spændingskorrosion er størst, når korrosionsmiljøet er justeret ind til at repræsentere en smal balanceret grænse mellem en kraftigt stresset passivitet og en fuldstændig aktivering af det rustfrie stål. Det kræver virkelig en balancering, for hvis balancen svinger mod mere passivitet, så får man grubetæring og hvis balancen går mere i retning af aktivering, får man generel korrosion. Miljøet skal befinde sig lige på knivsæggen for at spændingskorrosionen opstår. Hvordan opnås disse forhold? Her skal vi betragte de salte, der findes på den rustfri overflade og deres såkaldte kritiske fugtighed. Den kritiske fugtighed for et salt er den fugtighed som saltet er i ligevægt med, og ved hvilken overfladen bliver egentlig fugtig. Vi kender udmærket til dette forhold fra f.eks. calciumklorid, der er kendt som et vandsugende stof, og som har en kritisk fugtighed på ca. 30% RF, hvilket vil sige, at overfladen er fugtig ved luftfugtigheder over 30% RF og først begynder at tørre ud ved fugtigheder under 30% RF. De salte, der befinder sig på overfladen er som ovenfor nævnt klorider med kationerne calcium, magnesium, natrium, krom, jern og nikkel. For calcium- og magnesiumklorid er den kritiske fugtighed nede i området 30-35%, medens den for natriumklorid er betydelig højere. For metalsaltene ligger jernkloriderne fra meget lavt til 45-55%, medens krom- og nikkelkloridernes ikke er bekendt. Når man summer det samlede billede op, kan det ikke afvises, at overflademiljøets kritiske fugtighed ligger i området 30-35%. Det betyder, at ved en givet mængde saltforurening og korrosionsprodukter er overfladen ganske fugtig ved fugtigheder over 30-35% RF, og i øvrigt ikke særligt afhængig af den aktuelle fugtighed. Når fugtigheden sænkes ned til den kritiske fugtighed og derunder, begynder overfladen at tørre ud. Denne udtørring resulterer i, at saltkoncentrationen og hermed kloridkoncentrationen stiger gradvist, hvilket gør miljøet mere aggressivt. Denne udvikling fører til, at vi på et tidspunkt under udtørringen har nået den balance, der fører til spændingskorrosion. Denne udvikling er i princippet helt analog til situationen, som kendes fra inddampende kloridopløsninger, som vi ved fører til spændingskorrosion blot normalt ved højere temperatur. Eller alternerende inddampning og opfugtning, der anses for endnu mere spændingskorrosionsfremkaldende end bare inddampning. Det specielle ved svømmehalsmiljøet er, at optørringen først kan begynde ved 30-35% RF. Er korrosionsmiljøet blevet værre i de senere år? Når man ser på hyppigheden af skader ikke mindst spændingskorrosionsskader kan man godt få det indtryk, at det atmosfæriske korrosionmiljø i svømmehallerne i de senere år er blevet værre for rustfrit stål. Og selv om en forøget anvendelse af rustfrit stål i hallerne i sig selv kunne være ansvarlig for et stigende antal skader, må konklusionen være, at miljøet er blevet vanskeligere. Den moderne anvendelse af svømmehaller resulterer ikke alene i en højere udnyttelsesgrad flere badende i hallen, men også den moderne brug af hallerne som vandlande EBR/JQH-12
13 vil føre til forøget korrosiv belastning af det rustfrie stål. Det er indlysende, at aktiviteter som vandrutschebaner, fontæner, vandfald og lignede kan føre til forøget dannelse af aerosoler af badevand, hvilket forøger kloridforureningsgraden for ståloverfladerne. De samme argumenter kan anvendes for at forvente, at en øget kontakt mellem vandoverflader eventuelt i fordråbet form og luften vil skabe øget udveksling af flygtige stoffer, og dermed lette afgivelsen af kloraminer til luften med øget forurening af ståloverfladerne til følge. Hvad der derimod er nyt, er at en øget beluftning af vandet, som kan være konsekvensen af den megen bevægelse i vandet, er medvirkende til at øge kloramindannelsen i vandet. En forøget kloramindannelse må medføre en øget kloraminafgift til halluften og dermed skærpe korrosionspåvirkningen på det rustfrie stål. Med det scenario må konklusionen være, at hvis man vil anvende rustfrit stål til bærende strukturer, herunder ophæng, skal der anvendes de højest legerede rustfri ståltyper for at sikre mod risiko for spændingskorrosion i halatmosfæren. Hvis den løsning er økonomisk uacceptabel, må der anvendes alternative materialer som for eksempel coatede stål. EBR/JQH-13
14 Referencer: 1. N. Arnold, P.Gümpel & T.W. Heitz: Chloridinduzierte Korrosion von nichtrostenden Stählen in Schwimmhallen-Atmosphären. Teil 3: Einfluss einer realen Schwimmhallen-Atmosphären Werkstoffe und Korrosion, vol. 50, pp J.W. Oldfield & B. Todd: Room temperature stress corrosion cracking of stainless steels in indoor swimming pool atmospheres. British Corrosion Journal, vol. 26, pp Ulf Sender: Stress Corrosion Cracking on stainless steel in Swedish swimming pool buildings. Stainless Steel World, July/August, pp J.J.N. Heselmans & J.E.H. van Duin: Stress corrosion of stainless steels in swimming pools Stainless Steel World, December, pp Jesper N. Holst: Spændingskorrosion i rustfrit stål i svømmehal Vintermødet 2004, pp Dansk Metallurgisk Selskab EBR/JQH-14
Atmosfærisk korrosion af rustfrit stål Korrosionsforhold? Hvilke rustfri ståltyper kan anvendes hvor?
www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group Trods sit flotte og stolte navn er rustfrit stål desværre ikke altid rustfrit. Afhængig af ståltypen og miljøforholdene kan stålet blive
Læs mereHygiejnisk design og mikrobiologi, med fokus på korrosion af metaloverflader
Hygiejnisk design og mikrobiologi, med fokus på korrosion af metaloverflader Gårdteknisk forum / Kemidag - SEGES Annette Baltzer Larsen abl@force.dk FORCE Technology Agenda Korrosion Hygiejnisk design
Læs mereKorrosion i praksis. Troels Mathiesen. Afdelingen for Korrosion og Metallurgi trm@force.dk
Korrosion i praksis Troels Mathiesen Specialist, civ.ing., ph.d. Afdelingen for Korrosion og Metallurgi trm@force.dk Kundeopgaver: 50% Skadesopklaring 50% Rådgivning, korrosionstest, R&D Specialer: rustfrit
Læs mereKorrosion af rustfrit stål. Korrosionsformer, legeringselementer og miljøforhold. www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group
www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group Rustfrit stål er et korrosionsmæssigt set genialt materiale. Netop den gode korrosionsbestandighed kombineret med en (stadigvæk!) rimelig
Læs mereTemadag om vandbehandling og korrosion
Korrosionsformer Korrosion generelt Våd korrosion Korrosion typer i fjernvarmesystemer Materiale typer og korrosion Temadag om vandbehandling og korrosion Lea Korcakova, Bioenergy and Thermal Power, COWI
Læs mereHvad er forskellen på EN 1.4404 og EN 1.4571?
Hvad er forskellen på EN 1.4404 og EN 1.4571? Af Ebbe Rislund, Troels Mathiesen og J. Vagn Hansen Afdelingen for Korrosion og Metallurgi, FORCE Technology Indledning De to stål EN 1.4404 og EN 1.4571 er
Læs mereRustfrie stål. af Carsten Jensen Afdelingen for Korrosion og Metallurgi FORCE Technology. CSJ / 2009.01.22 rev. 01
Rustfrie stål af Carsten Jensen Afdelingen for Korrosion og Metallurgi FORCE Technology CSJ / 2009.01.22 rev. 01 FORCE Forretningskoncept Industri og samfund Undervisning og formidling Integrity Management
Læs mereSkadesanalyse: Spændingskorrosion i rustfrit stål i svømmehal
Skadesanalyse: Spændingskorrosion i rustfrit stål i svømmehal Jesper Nielsen Holst Materialeprøvning Teknologisk Institut Abstrakt: Spændingskorrosion i rustfrit stål er et kendt og frygtet problem i svømmehaller,
Læs mereNordisk Vattenskadeseminarium 2007 i Ystad
Korrosionserfarenheter från danska installationskomponenter Nordisk Vattenskadeseminarium 2007 i Ystad 31. August 2007 Asbjørn Andersen, akademiingeniør i kemi Korrosion og metallurgi FORCE Technology
Læs mereHvad er rustfrit? i 1. Rustfrit stål
Hvad er rustfrit? i 1 Rustfrit stål Rustfrit stål er en fælles betegnelse for en mængde stål med den fællesnævner, at de indeholder mindst 11,5% chrom. Når jern legeres med mindst 11,5% chrom, reagerer
Læs mereKorrosion af rustfrit stål
Kor r os i on afr us t f r i ts t ål Kor r os i ons f or mer, l eger i ngs el ement er ogmi l j øf or hol d Korrosion af rustfrit stål Korrosionsformer, legeringselementer og miljøforhold Rustfrit stål
Læs mereRustfrit stål og Rouge i Sterilcentraler
Rustfrit stål og Rouge i Sterilcentraler FDS og FSSD temadag 24. januar 2018 EML / NIRAS Indhold Brug af Rustfrit Stål og Rouge i Sterilcentraler Rustfrit stål - Typer - Hvad gør stål rustfrit - Passivering
Læs mereRustfrit stål i husholdningen
www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group Rustfrit stål er det tætteste, man kan komme på en standardlegering til kritiske formål, og vore hjemlige køkkener er ingen undtagelser.
Læs mereMaterialer og korrosion - offshore
Materialer og korrosion - offshore FMV Temadag 28. januar 2010 Anne Dorthe Hede andh@teknologisk.dk tlf.: 7220 2235 Seniorkonsulent Korrosion & Metallurgi Center for Materialeprøvning, Teknologisk Institut
Læs mereLavkulstof, titanstabiliseret og normalt, rustfrit stål
Lavkulstof, titanstabiliseret og normalt, rustfrit stål Myter og sandheder - og hvad er egentlig forskellen? Damstahl Group: Germany, Denmark, Sweden, Norway, the Netherlands, Slovenia and Finland Lavkulstof,
Læs mereTypiske skader på rustfrie materialer
Typiske skader på rustfrie materialer af J. Vagn Hansen og Carsten Jensen FORCE Technology 2016.02.01 Disposition Generelt om skades undersøgelser (CSJ) Case 1: Eksempel på forkert termisk påvirkning (CSJ)
Læs mereFerritisk, rustfrit stål. Korrosionsforhold og mekaniske forhold muligheder og begrænsninger. www.damstahl.dk
Korrosionsforhold og mekaniske forhold muligheder og begrænsninger Ferritisk, rustfrit stål Ferritisk, rustfrit stål For kun få år siden var nikkelfrit, ferritisk, rustfrit stål noget, man grinede af.
Læs mereKemisk overfladebehandling af rustfrit stål
www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group Al bearbejdning af rustfrit stål medfører en risiko for svækkelse af stålets naturlige korrosionsbestandighed. Er denne svækkelse større,
Læs mereKemisk overfladebehandling af rustfrit stål
Kemisk overfladebehandling af rustfrit stål De forskellige processer, virkemåde, fordele og ulemper Damstahl Group: Germany, Denmark, Sweden, Norway, the Netherlands, Slovenia and Finland Kemisk overfladebehandling
Læs mereDe første forslag, der også foreslås udført først, er mere detaljeret beskrevet i nedenstående.
Gudhjem Svømmehal Forslag til beskyttelse af konstruktionsdele 2009-04-25 Forslag og prioritering af reparationer I henhold til aftale har vi udarbejdet et forslag for renovering af bassinkonstruktionen
Læs mereUndersøgelse af befæstelsesmidler i Svendborg Badeland. Svendborg Idrætscenter (Svømmeland) Ryttervej50 DK-5700 Svendborg
Rapport Undersøgelse af befæstelsesmidler i Svendborg Badeland foretaget for: Svendborg Idrætscenter (Svømmeland) Ryttervej50 DK-5700 Svendborg Att.: Jan Damgaard CHV/BBJ 2007.12.21 Materialeprøvning Kongsvang
Læs mereRenoveringer
A. Renovering af bade og omklædningsrum. Dette er nødvendigt, da der hygiejnemæssigt ikke kan gøres ordentligt rent, og der altid vil stå noget vand og snavs i fugerne, som så vil være grobund for bakterier
Læs mereClaus Qvist Jessen: Rustfrit stål; overflader til food/pharma DTU d. 26. august 2015
Claus Qvist Jessen: Rustfrit stål; overflader til food/pharma DTU d. 26. august 2015 Agenda; DTU d. 26/8-2015 Korrosion af rustfrit stål Hvad er rustfrit stål? Korrosionsformer, legeringselementer, miljøforhold
Læs mereNye materialer nye udfordringer. v/ Lars Nøhr-Nielsen, FORCE Technology
Nye materialer nye udfordringer v/ Lars Nøhr-Nielsen, FORCE Technology Oversigt Materialevalg, nye (og gamle) anlæg Bestemmelser og litteratur for brugsvandsanlæg Oplæg til at forstå de nye udfordringer
Læs mereRustfrit stål. Ferrit vs. austenit. Ni = 0 % Ni > 8 % Austenitisk: C Tyggegummistål. Martensitisk: Duplex (F/A): C Tofaset < 0,03 Ferrit-Austenit
Rustfrit stål Austenitisk: C Tyggegummistål < 0,08 % (< 0,03) Cr Svejsbare 16 % konstrukt.stål Ni God 825 korrosionsbest. % 70 Mo % 06 af % RS worldwide Martensitisk: C Hærdbare 0,11,2 % pga. C Cr Hårde
Læs mereCheckPoint World
CheckPoint World - DANVAK Dagen - 10. april 2019 Side 1 af 26 CheckPoint World - 1999-2019 CheckPoint World Rindsholmvej 39D DK - 8800 Viborg 40 76 95 96 checkpointworld@gmail.com Lars Grøn Schjoldager
Læs mereRustfri armering; En fordel eller bare dyrt! Jens Henriksen
Rustfri armering; En fordel eller bare dyrt! FORCE Technology: Metallurgi Sammenføjninger: Svejse, lodde, bolte Korrosion og anden nedbrydning af metaller NDT: alle typer Overvågning: bevægelser, spændinger,
Læs mereRustfrit Stål Bassiner og Udstyr
Rustfrit Stål Bassiner og Udstyr 19.11-2017 Lene Bach Processing Omsætning: + 200 mill DKK Velvære & Vand - er tæt knyttet til hinanden nøglen til succes er: Teknik Drift Vedligehold I nært samspil med
Læs mereKorrosion i skroggennemføringer og søventiler
Korrosion i skroggennemføringer og søventiler Af Piet Jansen FORCE Technology Piet Jansen 2004 -- Kopiering og eftertryk tilladt med kildeangivelse Korrosion i skroggennemføringer og søventiler Sejlads
Læs mereDANSK FJERNVARME. Glykol systemer korrosion m.m.
DANSK FJERNVARME Glykol systemer korrosion m.m. OVERSIGT Korrosion Betingelser for korrosion Korrosionsformer Glycol Nedbrydning Inhibitorer Analyser Hvad analyseres der for Tolkning af analyser VANDKVALITETSKRAV
Læs mereUndgå fejl og skader i installationerne
Undgå fejl og skader i installationerne Korrosionsskader i vandinstallationer Vandskadedag 10. marts 2016 Frank Fontenay FORCE Technology Undgå fejl og skader i installationerne Forenklede råd Korrosion
Læs mereFordele og ulemper ved brug af aluminium i fødevareindustrien
Fordele og ulemper ved brug af aluminium i fødevareindustrien Temadag Alternative materialer til procesudstyr i fødevareindustrien 19. Maj 2010 Anne Deacon Juhl www.anodizingworld.com AluConsult Startet
Læs mereReferencelaboratoriet for måling af emissioner til luften
Referencelaboratoriet for måling af emissioner til luften Notat Titel Om våde røggasser i relation til OML-beregning Undertitel - Forfatter Lars K. Gram Arbejdet udført, år 2015 Udgivelsesdato 6. august
Læs mereMagnesiumoxid-plader
Magnesiumoxid-plader Vindtæt afdækning i lette facader Tommy Bunch-Nielsen, Typiske konstruktionsopbygninger 1 ppm 28-09-2015 MgO pladers sammensætning Magnesiumoxid og magnesiumklorid danner bindemiddel
Læs mere1. Er Jorden blevet varmere?
1. Er Jorden blevet varmere? Af Peter Bondo Christensen og Lone Als Egebo Ja, kloden bliver varmere. Stille og roligt får vi det varmere og varmere. Specielt er det gået stærkt gennem de sidste 50-100
Læs mereHvilken betydning har legeringselementerne i stål, og hvordan kan legeringssammensætningen bestemmes?
Hvilken betydning har legeringselementerne i stål, og hvordan kan legeringssammensætningen bestemmes? Af Carsten Jensen, FORCE Technology, Afdelingen for Korrosion & Metallurgi Risø-DTU, Roskilde, 24.
Læs mereDamstahl - a memeber of the NEUMO-Ehrenberg-Group
Damstahl - a memeber of the NEUMO-Ehrenberg-Group Teknisk information Index - Teknisk information 1 Hvad er rustfri stål? What is Stainless Steel? 2 Rustfrit ståls legeringselementer The Alloying Elements
Læs mereFerritisk, rustfrit stål
www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group For kun få år siden var nikkelfrit, ferritisk, rustfrit stål noget, man grinede af. Ringe korrosionsbestandighed, ringe svejsbarhed og ringe
Læs mereFerritisk, rustfrit stål
Ferritisk, rustfrit stål Mekaniske forhold og korrosionsforhold - muligheder og begrænsninger Damstahl Group: Germany, Denmark, Sweden, Norway, the Netherlands, Slovenia and Finland Ferritisk, rustfrit
Læs mereMgO-plader egenskaber og dokumentation
MgO-plader egenskaber og dokumentation Tommy Bunch-Nielsen Bunch Bygningsfysik 1 Hvad er MgO-plader Vindspærre plader- 8 eller 12 mm Bindemiddel Magnesiumoxyclorid også kaldet Sorel Cement Overskud af
Læs mereMåling af ledningsevne. I rent og ultrarent vand
Måling af ledningsevne I rent og ultrarent vand Anvendelse af ledningsevne Mest anvendt til kvalitets kontrol Overvågning af renhed på vand til processen Kontrol af vand i processen Kontrol af drikkevand
Læs mereFacts om: Bejdsning af rust- og syrefaststål
Facts om: Bejdsning af rust- og syrefaststål KD Industribejdsning Indholdsfortegnelse Forord... 2 Rust og syrefaststål, korrosionstyper... 4 Mekanisk overfladebehandling... 5 Kemisk overfladebehandling...
Læs mereKondens i moderne byggeri
Kondens i moderne byggeri Kondens er et naturligt fænomen og ikke et produktproblem. Det er tegn på høj luftfugtighed, hvilket betyder, at øget ventilation er nødvendig. En gennemsnitlig familie på fire
Læs mereKorrosion i biofyrede anlæg
Korrosion i biofyrede anlæg Af Trine Nybo Lomholt, specialist & Søren Klinggaard, projektleder Halm og flis er attraktive brændsler, men når det gælder korrosion, er udfordringerne større ved fyring med
Læs mereMaterialevalg til vandinstallationer i Rønne
Rønne Vand- og Varmeforsyning A.m.b.a. marts 2010 Materialevalg til vandinstallationer i Rønne Vand fra værk til forbruger Det er målet for Rønne Vand- og Varmeforsyning (RVV) at producere drikkevand af
Læs mereHavnestiger - Produktbeskrivelse
Havnestiger - Produktbeskrivelse Bagh & Co A/S har i mange år produceret tagstiger, som især afsættes til Sverige. Stigerne er nu videreudviklet til anvendelse som nødstiger i havne. Da der ikke er nogen
Læs mereSur-Tech A/S Surface Technology
Sur-Tech A/S Surface Technology KEMISK NIKKEL En slid og korrosionsbeskyttende belægning DS/ ISO 9001 ISO 14001 Kvalitetssikring Miljøledelse Hvad er kemisk nikkel? Kemisk nikkel er en proces til udfældning
Læs mere2013 Produktoversigt
Produktoversigt 2013 DST-DEGREEZ/2 ph 7,1 Kan anvendes på alle metaller og legeringer og neutrale olier. DST-DEGREEZ/3 ph 10,6 Kan anvendes på de fleste metaller og legeringer. Gode resultater med renoveringsgods.
Læs mereVidereuddannelse indenfor rustfrit stål Hvem, hvad, hvor, hvorfor og hvordan?
Videreuddannelse indenfor rustfrit stål Hvem, hvad, hvor, hvorfor og hvordan? Claus Qvist Jessen, Damstahl a/s Damstahl a/s: Rustfri stålgrossist Danmarks største Medlem af Neumo-Ehrenberg-gruppen: Sterile
Læs mereSlidstyrke af højtryksdyser behandlet med TRD Kromkarbid
Slidstyrke af højtryksdyser behandlet med TRD Kromkarbid TRD Surfaces Mads Brink Laursen - Temadag hos Force Technology, Brøndby, 2018.11.02 Højtydende, slid- og korrosionsbestandige overflader til særligt
Læs mereMåleprogrammet i Komforthusene
Måleprogrammet i Komforthusene Komforthus Konference Aalborg, 10. november 2009 Tine S. Larsen Adjunkt, PhD Institut for Byggeri og Anlæg Aalborg Universitet tsl@civil.aau.dk http://www.civil.aau.dk/~i6tsl/
Læs mereFremtidens lavenergibyggeri - kan vi gøre som vi plejer?
Fremtidens lavenergibyggeri - kan vi gøre som vi plejer? InnoBYG Kick-Off konference, 13. oktober 2010 Tine S. Larsen Lektor, PhD Institut for Byggeri og Anlæg Aalborg Universitet tsl@civil.aau.dk 1 NEJ
Læs mereBearbejdning af rustfrit stål
www.damstahl.dk Damstahl - a member of the NEUMO Ehrenberg-Group Kun de færreste anvender rustfrit stål uden at bearbejde det. Stålet skal klippes, bukkes, svejses, slibes eller på anden måde udsættes
Læs mereKASO DeZign. KASO-DeZign Engdraget 21 2500 Valby Tel: 3323 3131 e-mail: info@kaso.dk www.kaso.dk Cvr.nr. 28 887 086
KASO DeZign KASO-DeZign Engdraget 21 2500 Valby Tel: 3323 3131 e-mail: info@kaso.dk www.kaso.dk Cvr.nr. 28 887 086 Velkommen til KASO Care-line KASO Care-line er en komplet serie af støttebøjler og andre
Læs mereUni. Køkkenvaske. Datablad
Uni Køkkenvaske Datablad Beskrivelse Køkkenvaske i mat eller poleret stål med prop eller strainer. Produktegenskaber Køkkenvask til nedfældning. (AISI 304). Indeholder krom og nikkel. 100% genanvendeligt
Læs mereGod luft: Hvordan kan krav om høj luftkvalitet og lavt energiforbrug forenes?
God luft: Hvordan kan krav om høj luftkvalitet og lavt energiforbrug forenes? Temadag 10. juni 2010 Tine S. Larsen Lektor Institut for Byggeri og Anlæg Aalborg Universitet tsl@civil.aau.dk 1 Udgangspunktet
Læs mereLavtemperaturfjernvarme. Christian Kepser, 19. marts 2013 Energi teknolog studerende. SFO Højkær
SFO Højkær Lavtemperaturfjernvarme Christian Kepser, 19. marts 213 Energi teknolog studerende Indledning Lavtemperatur fjernvarme er som nævnet antyder, fjernvarme med en lavere fremløbstemperatur. Fremløbstemperaturen
Læs mereHoldbarhed af CRC. Belastede bjælker i saltvand
Holdbarhed af CRC Matricen i CRC er ekstremt tæt og har stort set ikke nogen kapillarporøsitet - kun gelporer - og derfor er permeabiliteten meget lav. Det betyder at CRC er meget bestandigt overfor påvirkninger
Læs mereIndeklima i lavenergibyggeri - kan vi gøre som vi plejer?
Indeklima i lavenergibyggeri - kan vi gøre som vi plejer? InnoByg Workshop 11. november 2011 Ole Daniels Forskningsassistent Institut for Byggeri og Anlæg Aalborg Universitet od@civil.aau.dk 1 NEJ Ole
Læs mereManual til SMC Saltgenerator. Type 30-300520 / 30-300530
Manual til SMC Saltgenerator. Type 30-300520 / 30-300530 Der tages forbeholde for evt. produktændringer. Copyright. Welldana A/S. Udgave 1.3 05 2005. Dansk. 1. Hvad er en saltgenerator? En saltgenerator
Læs mereInstrumentlære. Grunduddannelse for sterilcentralassistenter. Peter Christensen Opitek ApS InstrumentSpecialisten www.opitek.dk mail@opitek.
Instrumentlære Grunduddannelse for sterilcentralassistenter Peter Christensen Opitek ApS InstrumentSpecialisten www.opitek.dk mail@opitek.dk KIRURGISKE INSTRUMENTER Materialer Fremstilling Pleje & Håndtering
Læs mereSpændingsrækken angiver metallers (og hydrogens) villighed til at afgive elektroner.
Galvanisk Tæring Rent vand kan ikke lede elektrisk strøm, men det kan saltvand. Hvis man anbringer to forskellige metaller i saltvand, vil der gå en svag elektrisk strøm. Det er groft sagt efter samme
Læs mereVandkvalitet og risiko for korrosion. Leon Buhl Teknologisk Institut
Vandkvalitet og risiko for korrosion Leon Buhl Teknologisk Institut Leon Buhl, Teknologisk Vandkvalitet og risiko for korrosion 1. Korrosion generelt Leon Buhl, Teknologisk Bygningsreglementerne 8.4 Vand-
Læs mereDetektion af fejl og revner i procesudstyr
ARTIKEL Detektion af fejl og revner i procesudstyr Revner og tæringer på indersiden af procesudstyr er en tikkende bombe under en levnedsmiddelvirksomhed, da organisk materiale fra produktionen kan samles
Læs mereIndeklimaundersøgelse i 100 danske folkeskoler
Indeklimaundersøgelse i 100 danske folkeskoler - Tilbagemelding til skolerne Udarbejdet af: Eva Maria Larsen & Henriette Ryssing Menå Danmarks Tekniske Universitet December 2009 Introduktion Tak, fordi
Læs mereVallensbæk Strands Vandforsyning Amba.
Vallensbæk Strands Vandforsyning Amba. Blødgøring af drikkevand Dato: Mandag d. 19. marts 2018 Baggrund Vandets hårdhed i Danmark 25 dh Vandets totale hårdhed er defineret ved vandets indhold af calcium
Læs mereRensning for salte. Nikolaj Bjerring Jensen
Rensning for salte Nikolaj Bjerring Jensen Opkoncentrering af salte Opkoncentrering af salte kan være et problem hvis man bruger boringsvand og recirkulering Opkoncentrering af salte - Vand - Næringssalte
Læs mereSådan kan Innovationsnetværket PlastNet hjælpe dig. v/dorte Walzl Bælum Odense, den 23. september 2014
Sådan kan Innovationsnetværket PlastNet hjælpe dig v/dorte Walzl Bælum Odense, den 23. september 2014 1 Hvem er vi? 2 Plast Center Danmark Plast Center Danmark, PCD, er en erhvervsdrivende fond, som blev
Læs mereSVØMMEHALLER. Ventilationsaggregater af. komposit
SVØMMEHALLER Ventilationsaggregater af komposit Vores styrke, din fordel FORDELE > Korrossionsfri Lang levetid, lav vedligeholdelse > Lav vægt Forstærkning af tagkonstruktionen er unødvendig > Hygiejnisk
Læs mereSVØMMEBADSAFFUGTERE FOR KOMFORT OG WELLNESS
SVØMMEBADSAFFUGTERE FOR KOMFORT OG WELLNESS AFFUGTERE AF HØJ KVALITET OG FLOT DANSK DESIGN TIL INSTALLATIONER I POOL- OG TEKNIKRUM Svøebadsaffugtere for komfort og wellness Effektiv styring af luftfugtigheden
Læs mereSVØMMEBADSAFFUGTERE FOR KOMFORT OG WELLNESS
SVØMMEBADSAFFUGTERE FOR KOMFORT OG WELLNESS AFFUGTERE AF HØJ KVALITET OG FLOT DANSK DESIGN TIL INSTALLATIONER I POOL- OG TEKNIKRUM S vøebadsaffugtere for komfort og wellness Effektiv styring af luftfugtigheden
Læs mereRekvirent: XX. Udført af indeklimakonsulent: Ole Borup. Inspektion udført: København den XX oktober 2014. Sag nr.: 10XXX-14.
Rekvirent: XX Udført af indeklimakonsulent: Ole Borup info@termo-service.dk Skibhusvej 428 5000 Odense C +45 29821362 Cvr: 32592368 Inspektion udført: København den XX oktober 2014 Sag nr.: 10XXX-14 Indledning
Læs mereTOP RAILING. Glasværn Gelændersystemer
TOP RAILING Glasværn Gelændersystemer MAB TOP RAILING SYSTEM -en rigtig løsning til ethvert formål! Top Railing Systemerne er det rigtige produkt valg, til alle værn løsninger, hvor æstetik, flot udseende,
Læs mereRustfri kæde og tilbehør. Stainless Chain and Accessories. Indhold. Connex Chainlock CK
kæde og tilbehør Indhold Kæde DIN 5685C Kæde DIN 766A Kæder og komponenter Nødled Pladelås BG-SS bøjlewirelås karabinhage kovs kædesling masterlinks Chain and Accessories Index Chain DIN 5685C Chain DIN
Læs mereKÆLDRE ER FUGTTEKNISK SET KOMPLICEREDE
KÆLDRE ER FUGTTEKNISK SET KOMPLICEREDE Der er stor forskel på fugt- og temperaturforholdene i de dele af konstruktionerne, som ligger henholdsvis over og under terræn. Kældergulve vil i fugtteknisk henseende
Læs mereProblem: Mulig årsag: Afhjælpning: Produkter:
Uklart eller mælkeagtigt vand Flager/slimansamlinger i vandet og/eller i skimmeren og rørene Ubehagelig, indelukket lugt For mange organiske belastningsstoffer og/eller mikroorganismer (slimede vægge)
Læs mereEksperimentelle øvelser, øvelse nummer 3 : Røntgenstråling målt med Ge-detektor
Modtaget dato: (forbeholdt instruktor) Godkendt: Dato: Underskrift: Eksperimentelle øvelser, øvelse nummer 3 : Røntgenstråling målt med Ge-detektor Kristian Jerslev, Kristian Mads Egeris Nielsen, Mathias
Læs mereBrugermanual. HAJO pladeløfter SCC050 SCC075 SCC150 SCC300 SCC600
Brugermanual HAJO pladeløfter SCC050 SCC075 SCC150 SCC300 SCC600 Instruktion i korrekt brug af HAJO pladeløfter. Opbevar denne manual let tilgængelig for brugeren. Det er vigtigt at brugeren forstår advarslerne
Læs mereTERRASSEVARMER HN Brugervejledning
TERRASSEVARMER HN 12356 Brugervejledning Læs denne brugervejledning omhyggeligt, før terrassevarmeren tages i brug. Gem brugervejledningen, så du senere kan slå op i den. Pak terrassevarmeren ud og kontroller,
Læs mereGode råd om INDEKLIMAET i din bolig Brøndbyparken Afdeling 3
April 2013 Gode råd om INDEKLIMAET i din bolig Brøndbyparken Afdeling 3 De fleste af os opholder os inden døre mere end 90 % af tiden. Derfor er indeklimaet meget vigtig for vores sundhed. Mange forskellige
Læs mereER VEJSALT EN TRUSSEL MOD GRUNDVANDET?
ER VEJSALT EN TRUSSEL MOD GRUNDVANDET? Seniorforsker Birgitte Hansen, GEUS Lektor Søren Munch Kristiansen, Geologisk Institut, Aarhus Universitet Civilingeningeniør, ph.d. Flemming Damgaard Christensen,
Læs mereKOMPATIBLE TILSATSMATERIALER
Kompatible tilsatsmaterialer Side 1 af 9 Vi bruger cookies til at forbedre søgeoplevelsen og vedligeholde hjemmesiden. Ved at fortsætte, accepterer du brug af cookies. LÆS MERE (HTTP://WWW.ESAB.DK/DK/DA/ABOUT/PRIVACY.CFM)
Læs mereFremtidens lavenergibyggeri - kan vi gøre som vi plejer?
Fremtidens lavenergibyggeri - kan vi gøre som vi plejer? Energiseminar 11. maj 2011 Tine S. Larsen Lektor Institut for Byggeri og Anlæg Aalborg Universitet tsl@civil.aau.dk Tine Steen Larsen lektor Indeklima
Læs mereGrønbech. Stål & Metaldivisionen Rustfrit program
Grønbech Stål & Metaldivisionen Rustfrit program Rustfrie plader Rustfrie coils og båndstål Rustfrit stangstål Rustfrie rør Mønstervalsede plader Rustfrie dørkplader Plasmaskæring, Vandskæring Profiler
Læs mereHVAD ER KORROSION? AF DOUG JONES, BOSSARDS EKSPERTTEAM
HVAD ER KORROSION? AF DOUG JONES, BOSSARDS EKSPERTTEAM I visse tilfælde kan korrosion ses som tiltrækkende, som f.eks. en let patina på en kobbervandkande, der bruges til dekoration, men for det meste
Læs mereSpecialty Stainless Steel Processes
Specialty Stainless Steel Processes Bodycote Den foretrukne partner Det, du har brug for. Helt præcist. Bodycote tilbyder en komplet pakke med behandlinger varmebehandling, overfladeteknologi og varm isostatisk
Læs mereInstallationsvejledning IMage Pool heater.
Installationsvejledning IMage Pool heater. Der tages forbehold for evt. produktændringer. Copyright: International Marketing A/S Udgave: 3.1 10 2003. Sprog / language: DK. GB. D. F. Tillykke med Deres
Læs mereVand parameter beskrivelse
Vand parameter beskrivelse Farve Vandets farve har ikke i sig selv en sundhedsmæssig betydning, men har selvfølgelig en betydning for indtrykket af drikkevandets kvalitet - se også jern, mangan og NVOC.
Læs mereKorrosion i installationer kan undgås. Danvakdagen 5. april 2017 Leon Steen Buhl, Teknologisk Institut
Korrosion i installationer kan undgås Danvakdagen 5. april 2017 Leon Steen Buhl, Teknologisk Institut Agenda Hvad er korrosion i VVS installationer Vandkvalitet Materialer og korrosion Rustfrit stålrør
Læs mereVentilation. Ventilation kan etableres på to forskellige måder:
Rum, som benyttes af personer, skal ventileres så tilfredsstillende komfort og hygiejniske forhold opnås. Ventilationen bevirker, at fugt og forurening (partikler, CO 2, lugt mm.) fjernes fra opholdsrummene
Læs mereVedligeholdelse. Albia. Af: Stål, aluminium, kobber, galvanisering, træ og glas. Byggesag: Arne Andersen. Entrepriseafsnit: Lille Tingbakke, Vodskov
Albia Lupinvej 11, 9500 Hobro Tlf. 98 511 333 www.albia.dk post@albia.dk Vedligeholdelse Af: Stål, aluminium, kobber, galvanisering, træ og glas Byggesag: Arne Andersen Entrepriseafsnit: Lille Tingbakke,
Læs mereBLÆRER PÅ TRÆVÆRK. Stedvis ringe vedhæftning Ringe vedhæftning kan også have andre årsager end fugt alt efter malingtype.
Blærer på træværk BLÆRER PÅ TRÆVÆRK Blærer på træværk sådan kender vi dem Fra tid til anden opstår der blærer i maling på udvendigt træværk ofte kort efter, at det er blevet malet. Blærerne måler typisk
Læs mereFarvevariationer for nystøbt beton
Farvevariationer for nystøbt beton 1 Farvevariationer for nystøbt beton Farvevariationer hvad ser vi? Lyse og mørke område Brunlige misfarvninger Andet Hvad er den fysiske forandring i betonens overflade?
Læs mereArtikel om vindtætte plader af magnesiumklorid og magnesiumoxid. Vindtætte plader suger vand så det driver
Artikel om vindtætte plader af magnesiumklorid og magnesiumoxid Vindtætte plader suger vand så det driver I det fugtige efterår 2014 har det vist sig, at nogle vindtætte byggeplader baseret på magnesiumoxid
Læs mere2010 ProdUktovErsigt
2010 ProdUktovErsigt DST-DEGREEZ/2 ph 7,1 Kan anvendes på alle metaller og legeringer og neutrale olier. DST-DEGREEZ/3 ms/cm > 5,5 Svag basisk. ph 10,6 ms/cm > 4,0 Kan anvendes på de fl este metaller og
Læs mereKvalitetsordning for mikrobryggerier Good Manufacturing Practice (GMP)
1 GENERELLE GMP OG DESIGNPRINCIPPER Dette dokument beskriver generelle principper, som gælder for flere procesområder og funktioner, specifikt design- og bygningsmæssige aspekter, der har indirekte indflydelse
Læs mereUNDGÅ PROBLEMER MED MUG/SKIMMEL I VORE BOLIGER. Varde Bolig Administration
UNDGÅ PROBLEMER MED MUG/SKIMMEL I VORE BOLIGER Varde Bolig Administration Forsidebilledet er fra en pjece, som er udarbejdet af By og Byg, LBF og BL. Side 1 Forord: Fra sent efterår til tidlig forår (fyringssæson)
Læs mereQF Rør. QF rør findes i flere forskellige diametre og med tilbehør for hurtig og let installation
QF rør findes i flere forskellige diametre og med tilbehør for hurtig og let installation Fremstillet af galvaniseret stål, men til bydes også i rustfrit stål. QF rør er lasersvejste til og med ø450 mm.
Læs mereNOTAT. 1. Indledning. 2. Tjørnelyskolen
NOTAT Projekt Tjørnelyskolen, Stabilitet af tag over svømmehallen Kunde Greve Kommune, Ejendomsafdelingen Notat nr. 02 Dato 2015-04-20 Til Annette Sia Christensen, Jesper Nimgård, Fra Jens Brandt Kopi
Læs mereMetalafgivelse til drikkevand. Frank Fontenay, FORCE Technology
Metalafgivelse til drikkevand Frank Fontenay, FORCE Technology Temadag om sikre systemer til brugsvand TI Århus 25 februar 2008 Krav til drikkevand og materialer Drikkevand er et levnedsmiddel Krav til
Læs mere