1 tråds programmerbar transmitter Nr. 5331V114-DK Fra serienr CCOE
2 Revision Notes The following list provides notes concerning revisions of this document. Rev. ID Date Notes /45 IECEx and INMETRO approvals added /10 PESO/CCOE approval added GOST approval replaced with EAC approval 1546
3 2-TRÅDS PROGRAMMERBAR TRANSMITTER 5331 Indholdsfortegnelse Anvendelse... 2 Teknisk karakteristik... 2 Montage / installation... 2 Applikationer... 3 Bestillingsskema: Elektriske specifikationer... 4 Tilslutninger... 8 Blokdiagram... 9 Programmering Mekaniske specifikationer Montering af følerledninger Appendix ATEX Installation Drawing A ATEX Installation Drawing D IECEx Installation Drawing A IECEx Installation Drawing D FM Installation Drawing D CSA Installation Drawing D INMETRO Instruções de Segurança A INMETRO Instruções de Segurança D V114-DK 1
4 2-TRÅDS PROGRAMMERBAR TRANSMITTER 5331 Indgang for RTD, TC, Ohm eller mv Ekstrem målenøjagtighed 1,5 kvac galvanisk isolation Programmerbar følerfejlsværdi Kan monteres i DIN form B følerhoved Anvendelse Temperaturlineariseret måling med Pt100...Pt1000, Ni100...Ni1000 eller termoelementføler. Omsætning af lineær modstandsændring til standard analogt strømsignal, f.eks. fra ventiler eller ohmske niveaustave. Forstærkning af bipolært mv-signal til et standard ma strømsignal. Teknisk karakteristik PR5331 kan af brugeren i løbet af få sekunder programmeres til at måle inden for alle normerede temperaturområder. RTD og modstandsindgangen har kabelkompensering for 2-, 3- og 4-leder tilslutning. Der er løbende sikkerhedscheck af gemte data. Montage / installation Kan monteres i DIN form B følerhoved. I ikke-eksplosionsfarlige områder kan 5331 monteres på en DIN-skinne med PR-beslag type V114-DK
5 RTD til ma APPLIKATIONER 2-trådsinstallation i kontrolrum V+ ma TC til ma 2-trådsinstallation i kontrolrum V+ - ma Modstand til ma 2-trådsinstallation i kontrolrum V+ ma mv til ma 2-trådsinstallation i kontrolrum V+ - ma 5331V114-DK 3
6 Bestillingsskema: 5331 Type Version Omgivelsestemperatur Galvanisk isolation 5331 Standard : A CSA, FM, ATEX, IECEx & INMETRO : D -40 C C : VAC : B Elektriske specifikationer Specifikationsområde: -40 C til +85 C Fælles specifikationer: Forsyningsspænding DC Standard... 7, V CSA, FM, ATEX, IECEx & INMETRO... 7, VDC Egetforbrug mw...0,8 W Spændingsdrop... 7,2 VDC Isolationsspænding, test / drift... 1,5 kvac / 50 VAC Opvarmningstid... 5 min. Kommunikationsinterface... Loop Link Signal- / støjforhold... Min. 60 db Reaktionstid (programmerbar) s EEprom fejlcheck... < 3,5 s Signaldynamik, indgang bit Signaldynamik, udgang bit Kalibreringstemperatur C Nøjagtighed, størst af generelle og basisværdier: Generelle værdier Absolut Temperatur- Indgangstype nøjagtighed koefficient Alle ±0,05% af span ±0,01% af span / C V114-DK
7 Basisværdier Indgangstype Basisnøjagtighed Temperaturkoefficient RTD ±0,2 C ±0,01 C/ C Lin. R ±0,1 Ω ±10 mw / C Volt ±10 µv ±1 µv / C TC-type: E, J, K, L, N, T, U ±1 C ±0,05 C / C TC-type: B, R, S, W3, W5, LR ±2 C ±0,2 C / C EMC-immunitetspåvirkning... < ±0,5% af span Udvidet EMC-immunitet: NAMUR NE 21, A-kriterium, gniststøj... < ±1% af span Virkning af forsyningsspændingsændring... < 0,005% af span / VDC Vibration... IEC : Hz... ±1,6 mm Hz... ±4 g Max. ledningskvadrat... 1 x 1,5 mm 2 flerkoret ledning Klemskruetilspændingsmoment... 0,4 Nm Luftfugtighed... < 95% RH (ikke kond.) Mål... Ø 44 x 20,2 mm Kapslingsklasse (hus / klemme)... IP68 / IP00 Vægt g Elektriske specifikationer indgang: RTD- og lineær modstandsindgang: RTDtype Pt100 Ni100 Lin. R Min. værdi -200 C -60 C 0 W Max. værdi +850 C +250 C 5000 W Min. span 25 C 25 C 30 W Standard IEC DIN Max. nulpunktsforskydning (offset)... 50% af valgt max. værdi Kabelmodstand pr. leder (max.)... 5 Ω Følerstrøm... Nom. 0,2 ma Virkning af følerkabelmodstand (3- / 4-leder)... < 0,002 Ω/Ω Følerfejlsdetektering... Ja 5331V114-DK 5
8 TC-indgang: Type B E J K L N R S T U W3 W5 LR Min. temperatur +400 C -100 C -100 C -180 C -100 C -180 C -50 C -50 C -200 C -200 C 0 C 0 C -200 C Max. temperatur C C C C +900 C C C C +400 C +600 C C C +800 C Min. span 100 C 50 C 50 C 50 C 50 C 50 C 100 C 100 C 50 C 50 C 100 C 100 C 50 C Standard IEC584 IEC584 IEC584 IEC584 DIN IEC584 IEC584 IEC584 IEC584 DIN ASTM E ASTM E GOST Max. nulpunktsforskydning (offset)... 50% af valgt max. værdi Koldt loddestedskomp. (CJC)... < ±1,0 C Følerfejlsdetektering... Ja Følerfejlsstrøm: under detektering... Nom. 33 ma ellers... 0 ma Spændingsindgang: Måleområde mv Min. måleområde (span)... 5 mv Max. nulpunktsforskydning (offset)... 50% af valgt max. værdi Indgangsmodstand MΩ Udgang: Strømudgang: Signalområde ma Min. signalområde ma Opdateringstid ms Udgangssignal ved EEpromfejl... 3,5 ma Belastningsmodstand... (V forsyn. - 7,2) / 0,023 [Ω] Belastningsstabilitet... < ±0,01% af span / 100 Ω Følerfejlsdetektering: Programmerbar... 3, ma NAMUR NE43 Upscale ma NAMUR NE43 Downscale... 3,5 ma Af span = Af det aktuelt valgte område V114-DK
9 Godkendelser: EMC /108/EF CCOE... P337392/1 EAC... TR-CU 020/2011 Marinegodkendelse: Det Norske Veritas, Ships & Offshore... Stand. f. Certific. No. 2.4 Ex / I.S.: ATEX 94/9/EF 5331A... KEMA 10ATEX0002 X 5331D... KEMA 06ATEX0062 X FM-certifikat... 2D5A7 CSA-certifikat IECEx... DEK X INMETRO... DEKRA X CCOE... P337392/2 EAC Ex TR-CU 012/ RU C-DK.GB08.V V114-DK 7
10 + TILSLUTNINGER Indgang: RTD, 2-leder RTD, 3-leder RTD, 4-leder TC, intern CJC TC, extern CJC mv Modstand, 2-leder Modstand, 3-leder Modstand, 4-leder Udgang: 2-Trådsinstallation 1 2 ma V114-DK
11 - - BLOKDIAGRAM mv RTD, lin. R - tråd TC Ext. CJC + + mv Indgang gnd. 6 5 Int. CJC 4 3 M UX PGA A / D C PU EEPRO M ma Comm D / A ma 1 Forsyning + 7, VDC 2 Forsyning - ma ma 5331V114-DK 9
12 Tag no: 3-wire sec Upscale PROGRAMMERING Loop Link er et batteridrevet kommunikationsinterface, der er nødvendigt for programmering af Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PReset programmet. Loop Link må ikke benyttes til kommunikation med moduler installeret i Ex-område. Bestilling: Loop Link 1 2 Sort Rød Afbryd * Gul * Grøn Modtagende udstyr +Vforsyning Indgang 5331 Stikforbindelse File Product Input Output Communication Language Option 08:30:00 PRetop 5331 Date: Serial no: PRelectronics Analog input Analog output Input type: Pt100 DIN/IEC Output type: 4-20mA Input range: C Sensor error: Connection: Cold junction comp: Response time: Loop Link USB * Kun forbundet ved on-line programmering V114-DK
13 Mekaniske specifikationer Montering af følerledninger mm ø 44 mm ø 6 mm m m Ledninger monteres mellem metalpladerne 5331V114-DK 11
14 APPENDIX ATEX Installation Drawing A ATEX Installation Drawing D IECEx installation drawing A IECEx installation drawing D FM Installation Drawing D CSA Installation Drawing D INMETRO Instruções de Segurança A INMETRO Instruções de Segurança D V114-DK
15 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QA02 ATEX Installationstegning For sikker installation af 5331A3B eller 5334A3B skal følgende overholdes: Modulet må kun installeres af kvalificerede personer, som er bekendt med national og international lovgivning, direktiver og standarder i det land, hvor modulet skal installeres. Produktionsår fremgår af de to første cifre i serienummeret. ATEX-certifikat Mærkning KEMA 10ATEX 0002 X II 3 G Ex na [ic] IIC T4 T6 Gc II 3 G Ex ic IIC T4 T6 Gc II 3 D Ex ic IIIC Dc Standarder EN : 2012, EN : 2012, EN : 2010 T4: -40 Ta 85ºC T6: -40 Ta 60ºC Klemme: 3,4,5,6 Ex na [ic] Uo: 9,6 V Io: 25 ma Po: 60 mw Lo: 33 mh Co: 2,4 μf Klemme: 1,2 Ex na Umax. 35 VDC Klemme: 1,2 Ex ic Ui = 35 VDC Ii = 110 ma Li = 10 μh Ci = 1,0 nf Særlige betingelser for sikker anvendelse: For beskyttelsestype Ex na skal transmitteren monteres i et hus med en tæthedsgrad på mindst IP54 i overensstemmelse med EN Ved installationer i områder med potentiel eksplosionsfare på grund af brændbart støv, skal transmitteren monteres i et hus med en tæthedsgrad på mindst IP6X i overensstemmelse med EN Husets overfladetemperatur er 20 K over omgivelsestemperaturen. Hvis omgivelsestemperaturen 60 C, skal der bruges varmebestandige kabler med specifikationer på mindst 20K over omgivelsestemperaturen. Revision date: Version Revision V2R0-DK01 Page: 1/1 5331V114-DK 13
16 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QA01 ATEX Installationstegning For sikker installation af 5331D eller 5334B skal følgende overholdes: Modulet må kun installeres af kvalificerede personer, som er bekendt med national og international lovgivning, direktiver og standarder i det land, hvor modulet skal installeres. Produktionsår fremgår af de to første cifre i serienummeret. ATEX-certifikat Mærkning KEMA 06ATEX 0062 X II 1 G Ex ia IIC T4...T6 Ga II 1 D Ex ia IIIC Da I M1 Ex ia I Ma Standarder EN : 2012, EN : 2012, EN : 2007, EN :2010 Ex-område Zone 0, 1, 2, 20, 21, 22 Ikke Ex-område T4: -40 Ta 85ºC T6: -40 Ta 60ºC Klemme: 3,4,5,6 Uo: 9,6 VDC Io: 25 ma Po: 60 mw Lo: 33 mh Co: 2,4μF D 5334B Barriere Klemme: 1,2 Ui: 30 VDC Ii: 120 ma Pi: 0,84 W Li: 10μH Ci: 1,0nF Revision date: Version Revision V2R0-DK01 Page: 1/ V114-DK
17 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QA01 Installationsforskrifter Følerkredsløbet er ikke ufejlbarligt galvanisk isoleret fra indgangskredsløbet, men den galvaniske isolation mellem kredsene kan modstå en testspænding på 500 VAC i 1 minut. I områder med potential eksplosionsfare på grund af brændbar gas skal transmitteren installeres i et hus med en kapslingsklasse på mindst IP20 i overensstemmelse med EN Hvis transmitteren installeres i eksplosive atmosfærer, hvor kategori 1 G, 1 M eller 2 M udstyr er krævet, og hvis huset er lavet af aluminium, skal det installeres således, at der selv ved sjældent opstående hændelser ikke er risiko for antændelse på grund af stød og friktionsgnister; hvis huset er lavet af ikke-metallisk materiale, skal elektrostatiske ladninger på transmitterens hus undgås. For installation i områder med potentiel eksplosionsfare på grund af brændbart støv skal følgende overholdes: Transmitteren skal monteres i et form B metalhus i overensstemmelse med DIN Huset skal have en tæthedsgrad på mindst IP 6X i overensstemmelse med EN og skal være egnet til den pågældende applikation samt være installeret korrekt. Der må kun anvendes kabelforskruninger og blindstik, som egner sig til den pågældende applikation og som installeres korrekt. Hvis omgivelsestemperaturen 60 C, skal der bruges varmebestandige kabler med specifikationer på mindst 20K over omgivelsestemperaturen. Husets overfladetemperatur er lig med den maksimale omgivelsestemperatur plus 20 K for støvlag med en tykkelse på op til 5 mm. Revision date: Version Revision V2R0-DK01 Page: 2/2 5331V114-DK 15
18 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QI02 IECEx Installation drawing For safe installation of 5331A or 5334A the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. Certificate IECEx DEK X Marking Ex na [ic] IIC T4..T6 Gc Ex ic IIC T4..T6 Gc Ex ic IIIC Dc Standards IEC : 2011, IEC : 2011, IEC : 2010 T4: -40 Ta 85ºC T6: -40 Ta 60ºC Terminal: 3,4,5,6 Uo: 9.6 V Io: 25 ma Po: 60 mw Lo: 33 mh Co: 2.4 μf Terminal: 1,2 Ex na Umax =35 VDC Terminal: 1,2 Ex ic Ui = 35 VDC Ii = 110mA Li = 10 μh Ci = 1.0 nf Installation note: For installation in a potentialy explosive gas atmosphere, the following instructions apply: For na installation the transmitter must be installed in an metal enclosure, e.g. a form B enclosure providing a degree of protection of at least IP54 according to IEC60529 or in an enclosure with type of protection Ex n or Ex e. For ic installation the transmitter must be installed in enclosure providing a degree of protection of at least IP20 according to IEC60529 and that is suitable for the application. Cable entry devices and blanking elements shall fulfill the same requirements For an ambient temperature 60ºC, heat resistant cables shall be used with a rating of at least 20 K above the ambient temperature. For installation in a potentially explosive dust atmposphere, the following instructions apply: The surface temperature of the enclosure is equal to the ambient temperature plus 20 K, for a dust layer with a thickness up to 5 mm. The transmitter must be mounted in a enclosure according to DIN that provides a degree of protection of at least IP6X according to IEC60529, and that is suitable for the application. Cable entry devices and blanking elements shall fulfill the same requirements. Revision date: Version Revision V1R0 Page: 1/ V114-DK
19 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QI01 IECEx Installation drawing For safe installation of 5331D or 5334B the following must be observed. The module shall only be Installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number.. Certificate IECEx DEK X Marking Ex ia IIC T4 T6 Ga Ex ia IIIC Da Ex ia I Ma Standards IEC : 2011, IEC : 2011, IEC :2006 Hazardous area Zone 0, 1, 2, 20, 21, 22, M1 Non Hazardous Area T4: -40 Ta 85ºC T5: -40 Ta 60ºC T6: -40 Ta 45ºC Terminal: 3,4,5,6 Uo: 9.6 VDC Io: 25 ma Po: 60 mw Lo: 33 mh Co: 2.4 μf D 5334B Terminal: 1,2 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10 μh Ci: 1.0 nf Barrier Revision date: Version Revision V1R0 0Page: 1/2 5331V114-DK 17
20 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QI01 Installation notes. The sensor circuit is not infallibly galvanic isolated from the input circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during 1 minute. In a potentially explosive gas atmosphere, the transmitter shall be mounted in a metal form B enclosure in order to provide a degree of protection of at least IP20 according to IEC If however the environment requires a higher degree of protection, this shall be taken into account. If the transmitter is installed in an explosive atmosphere requiring the use of equipment protection level Ga, Ma and Mb, and if the enclosure is made of aluminum, it must be installed such, that ignition sources due to impact and friction sparks are excluded. For installation in a potentially explosive dust atmosphere, the following instructions apply: For explosive dust atmospheres, the surface temperature of the outer enclosure is 20 K above the ambient temperature. The transmitter shall be mounted in a metal enclosure form B according to DIN43729 that is providing a degree of protection of at least IP6X according to IEC60529, that is suitable for the application and correctly installed. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. For an ambient temperature 60ºC, heat resistant cables shall be used with a rating of at least 20 K above the ambient temperature. Revision date: Version Revision V1R0 0Page: 2/ V114-DK
21 LERBAKKEN 10, 8410 RØNDE DENMARK. 5300QF01 FM Installation Drawing 5300Q502 Rev AH Model 5331C,5331D, 5333C, 5333D and 5343B Hazardous (Classified) Location Class I,Division1, Groups, A,B,C,D T4..T6 Class I, Zone 0, AEx ia IIC T4..T6 Ambient temperature limits T4: 40 to + 85 deg. Celcius T6: 40 to + 60 deg. Celcius Terminal 1, 2 Vmax or Ui: 30 V Imax or Ii: 120 ma Pmax or Pi: 0.84 W 1 2 Ci: 1 nf Li:10 uh + Non Hazardous Location Associated Apparatus or Barrier with entity Parameters: UM < 250V Voc or Uo < Vmax or Ui Isc or Io < Imax or Ii Po < Pi Ca or Co > Ci + Ccable La or Lo > Li + Lcable Terminal 3,4,5,6 Vt or Uo: 9.6 V It or Io: 28 ma Pt or Po: 67.2 mw Ca or Co: 3.5 uf La or Lo: 35 mh 6 5 SENSOR 4 3 This device must not be connected to any associated apparatus which uses or generates more than 250 VRMS Model 5335C, 5335D, 5336D, 5337D Hazardous (Classified) Location Class I,Division1, Groups, A,B,C,D T4..T6 Class I, Zone 0, AEx ia IIC T4..T6 Ambient temperature limits T4: 40 to + 85 deg. Celcius T6: 40 to + 60 deg. Celcius Terminal 1, 2 Vmax or Ui: 30 V Imax or Ii: 120 ma Pmax or Pi: 0.84 W 1 2 Ci: 1 nf Li:10 uh + Non Hazardous Location Associated Apparatus or Barrier with entity Parameters: UM < 250V Voc or Uo < Vmax or Ui Isc or Io < Imax or Ii Po < Pi Ca or Co > Ci + Ccable La or Lo > Li + Lcable Terminal 3,4,5,6 Vt or Uo: 9.6 V It or Io: 28 ma Pt or Po: 67.2 mw Ca or Co: 3.5 uf La or Lo: 35 mh 6 5 SENSOR 4 3 This device must not be connected to any associated apparatus which uses or generates more than 250 VRMS Revision date: Version Revision V8R0 Doc. No. 5300Q502 Rev AH Page: 1/2 5331V114-DK 19
22 5300QF01 LERBAKKEN 10, 8410 RØNDE DENMARK. The entity concept The Transmitter must be installed according to National Electrical Code (ANSI-NFPA 70) and shall be installed with the enclosure, mounting, and spacing segregation requirement of the ultimate application. Equipment that is FM-approved for intrinsic safety may be connected to barriers based on the ENTITY CONCEPT. This concept permits interconnection of approved transmitters, meters and other devices in combinations which have not been specifically examined by FM, provided that the agency's criteria are met. The combination is then intrinsically safe, if the entity concept is acceptable to the authority having jurisdiction over the installation. The entity concept criteria are as follows: The intrinsically safe devices, other than barriers, must not be a source of power. The maximum voltage Ui(VMAX) and current Ii(IMAX), and maximum power Pi(Pmax), which the device can receive and remain intrinsically safe, must be equal to or greater than the voltage (Uo or VOC or Vt) and current (Io or ISC or It) and the power Po which can be delivered by the barrier. The sum of the maximum unprotected capacitance (Ci) for each intrinsically device and the interconnecting wiring must be less than the capacitance (Ca) which can be safely connected to the barrier. The sum of the maximum unprotected inductance (Li) for each intrinsically device and the interconnecting wiring must be less than the inductance (La) which can be safely connected to the barrier. The entity parameters Uo,VOC or Vt and Io,ISC or It, and Ca and La for barriers are provided by the barrier manufacturer. NI Field Circuit Parameters Model 5331C, 5331D, 5333C, 5333D, 5335C, 5335D, 5336D, 5337D and 5343B Hazardous (Classified) Location Class I,Division2, Groups, A,B,C,D T4..T6 Class I, Zone 2, IIC T4..T6 Ambient temperature limits T4: 40 to + 85 deg. Celcius T6: 40 to + 60 deg. Celcius + Non Hazardous Location Associated Apparatus or Barrier Terminal 1, 2 Vmax : 35 V Ci: 1.0 nf Li:10 uh This device must not be connected to any associated apparatus which 5 4 uses or generates more than 250 VRMS SENSOR Revision date: Version Revision V8R0 Doc. No. 5300Q502 Rev AH Page: 2/ V114-DK
23 LERBAKKEN 10, 8410 RØNDE DENMARK. 5335QE01 CSA Installation drawing 533XQC03 Hazardous area Non Hazardous Area T4: -40 Ta 85ºC T6: -40 Ta 60ºC Module 5331D, 5333D Terminal: 3,4,5,6 Only passive, or non-energy storing devices such as RTD s and Thermocouples may be connected Barrier Module 5335D, 5336D and 5337D Terminal: 3,4,5,6 Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 35 mh Co: 2.5 μf Terminal: 1,2 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10 μh Ci: 1.0 nf CLASS PROCESS CONTROL EQUIPMENT - Intrinsically Safe Entity - For Hazardous Locations Class I, Division 1, Groups A, B, C and D Ex ia IIC, Ga CLASS PROCESS CONTROL EQUIPMENT - Intrinsically Safe Entity - For Hazardous Locations - Certified to US Standards Class I, Division 1, Groups A, B, C and D Class I, Zone 0, AEx ia IIC, Ga Warning: Substitution of components may impair intrinsic safety. The transmitters must be installed in a suitable enclosure to meet installation codes stipulated in the Canadian Electrical Code (CEC) or for US the National Electrical Code (NEC). Revision date: Version Revision V4R0 Doc. No. 533XQC03 Page: 1/1 5331V114-DK 21
24 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QB02 Desenho de Instalação INMETRO Para instalação segura do 5331A ou 5334A o seguinte deve ser observado. O modo deve apenas ser instalado por pessoas qualificadas que são familiarizadas com as leis nacionais e internacionais, diretrizes e padrões que se aplicam a esta área. Ano de fabricação pode ser pego dos dois primeiros dígitos do número de série. Certificado Indicação DEKRA X Ex na [ic] IIC T4..T6 Gc Ex ic IIC T4..T6 Gc Ex ic IIIC Dc Padrões ABNT NBR IEC : 2008, ABNT NBR IEC : 2009, IEC : 2010, ABNT NBR IEC : 2008 T4: -40 Ta 85ºC T6: -40 Ta 60ºC Terminal: 3,4,5,6 Uo: 9,6 V Io: 25 ma Po: 60 mw Lo: 33 mh Co: 2,4 μf Terminal: 1,2 Ex na Umax =35 VDC Terminal: 1,2 Ex ic Ui = 35 VDC Ii = 110 ma Li = 10 μh Ci = 1,0 nf Notas para instalação Para a instalação em uma atmosfera de gás potencialmente explosivo, se aplicam as instruções a seguir: Para a instalação na o transmissor deve ser instalado em um gabinete de metal, por exemplo, gabinete em forma B que forneça um grau de proteção de pelo menos IP54 de acordo com IEC60529 ou em um caixa com tipo de proteção Ex n ou Ex e. Para a instalação ic o transmissor deve ser instalado em um invólucro proporcionando um grau de proteção de IP20, pelo menos, de acordo com a norma IEC60529 que é adequado para a aplicação. Dispositivos de entrada de cabos e elementos de supressão devem cumprir os mesmos requisitos. Para uma temperatura ambiente 60 º C, os cabos resistentes ao calor precisam ser utilizados com uma classificação de pelo menos 20 K acima da temperatura ambiente. Para a instalação em uma atmosfera de poeira potencialmente explosiva, se aplicam as instruções a seguir: A temperatura da superfície do invólucro é igual à temperatura ambiente mais 20 K, para uma camada de pó, com uma espessura superior a 5 mm. O transmissor deve ser montado em um invólucro de acordo com a norma DIN 43729, que proporciona um grau de proteção de, pelo menos, IP6X de acordo com a norma IEC60529, e que seja apropriado para a aplicação. Dispositivos de entrada de cabos e elementos de supressão devem cumprir as mesmas exigências. Revision date: Version Revision V1R0 Page: 1/ V114-DK
25 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QB01 Desenho de Instalação INMETRO Para instalação segura do 5331D ou 5334B o seguinte deve ser observado. O modo deve apenas ser instalado por pessoas qualificadas que são familiarizadas com as leis nacionais e internacionais, diretrizes e padrões que se aplicam a esta área. Ano de fabricação pode ser pego dos dois primeiros dígitos do número de série. Certificado DEKRA X Indicação Ex ia IIC T6 T4 Ga Ex ia IIIC Da Padrões ABNT NBR IEC : 2008 ABNT NBR IEC : 2009 IEC : 2010 ABNT NBR IEC : 2008 Áreas Perigosas Zona 0, 1, 2, 20, 21, 22, Sem áreas perigosas T4: -40 Ta 85ºC T5: -40 Ta 60ºC T6: -40 Ta 45ºC Terminal: 3,4,5,6 Uo: 9,6 VDC Io: 25 ma Po: 60 mw Lo: 33 mh Co: 2,4μF D 5334B Terminal: 1,2 Ui: 30 VDC Ii: 120 ma Pi: 0,84 W Li: 10μH Ci: 1,0nF Barrier Revision date: Version Revision V1R0 Page: 1/2 5331V114-DK 23
26 LERBAKKEN 10, 8410 RØNDE DENMARK. 5331QB01 Notas de instalação O circuito do sensor não é isolado galvanicamente infalível do circuito de entrada. Contudo, a isolação galvânica entre os circuitos é capaz de resistir a um teste de tensão de 500Vac durante 1 minuto. Em uma atmosfera de gás potencialmente explosiva, o transmissor deve ser montado em um enclousure a fim de garantir um grau de proteção de no mínimo IP20 de acordo com EN Se contudo o ambiente requer um nível de proteção maior, isso deve ser levado em conta Se o transmissor é instalado em uma atmosfera explosiva exigindo o uso de equipamento de categoria Ga e se o enclosure é feito de alumínio, ele deve ser instalado de modo que, mesmo em caso de avaria rara, fontes de ignição devido a impacto e fricção, faíscas são eliminadas; se o enclosure é feito de materiais não metálicos, cargas eletroestáticas devem ser evitadas. Para instalação em atmosfera de poeira potencialmente explosiva, as instruções a seguir: O transmissor deve ser montado em enclosure de metal forma B de acordo com DIN43729 que está fornecendo um grau de proteção de pelo menos IP6X de acordo com EN Isso é adequado para aplicação e corretamente instalado. As entradas dos cabos e os elementos de obturação que podem ser utilizados são adequados para a aplicação e corretamente instalados. Para temperatura ambiente >= 60ºC, fios de resistência ao calor devem ser usados com uma faixa de pelo menos 20K acima da temperatura ambiente. A temperatura da superfície do enclosure é igual à temperatura ambiente mais de 20 K, por uma camada de pó, com uma espessura até 5 mm. Revision date: Version Revision V1R0 Page: 2/ V114-DK
27 Displays Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearization, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces for analog and digital signals as well as HART signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 & 2 and for some devices in zone 20, 21 & 22. Isolation Galvanic isolators for analog and digital signals as well as HART signals. A wide product range with both looppowered and universal isolators featuring linearization, inversion, and scaling of output signals. Temperature A wide selection of transmitters for DIN form B mounting and DIN rail devices with analog and digital bus communication ranging from application-specific to universal transmitters. Universal PC or front programmable devices with universal options for input, output and supply. This range offers a number of advanced features such as process calibration, linearization and auto-diagnosis.
28 Head office Denmark PR electronics A/S Lerbakken 10 tel DK-8410 Rønde fax
Produktmanual tråds programmerbar transmitter
Produktmanual 5333 2-tråds programmerbar transmitter PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS No. 5333V114-DK Fra serienr. 132094001-132094630
Læs mereProduktmanual tråds programmerbar transmitter
Produktmanual 5331 2-tråds programmerbar transmitter PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS No. 5331V116-DK Fra serienr. 141365001
Læs mere2-tråds niveautransmitter. Nr. 5343V104-DK Fra serienr
5343 2-tråds niveautransmitter Nr. 5343V104-DK Fra serienr. 141298001 Revision Notes The following list provides notes concerning revisions of this document. Rev. ID Date Notes 104 14/14 IECEx, FM and
Læs mereProduktmanual tråds niveautransmitter
Produktmanual 5343 2-tråds niveautransmitter PERFORMANCE MADE SMARTER TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS No. 5343V107-DK Fra serienr. 141298001 6 produktområder
Læs mere2-tråds programmerbar transmitter. Nr. 6331V105-DK Fra serienr
6331 2-tråds programmerbar transmitter Nr. 6331V105-DK Fra serienr. 079224041 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereProduktmanual tråds programmerbar transmitter
PERFORMANCE MADE SMARTER Produktmanual 6333 2-tråds programmerbar transmitter TEMPERATUR Ex-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 6333V104-DK Fra serienr.: 1517871082
Læs mere2-tråds programmerbar transmitter. Nr. 6333V103-DK Fra serienr
6333 2-tråds programmerbar transmitter Nr. 6333V103-DK Fra serienr. 080629052 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mere2-tråds programmerbar transmitter. Nr. 5333V110-DK Fra serienr. 080629052 SIGNALS THE BEST
5333 2-tråds programmerbar transmitter Nr. 5333V110-DK Fra serienr. 080629052 SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til
Læs mereProduktmanual tråds transmitter med HART-protokol
Produktmanual 5335 2tråds transmitter med HARTprotokol PERFORMANCE MADE SMARTER TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY Nr. 5335V117DK Fra serienr.: 180971088
Læs mereProduktmanual tråds programmerbar transmitter
PERFORMANCE MADE SMARTER Produktmanual 6334 2tråds programmerbar transmitter TEMPERATUR ExBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 6334V106DK Fra serienr.: 159765033 6
Læs mereProduktmanual tråds programmerbar transmitter
PERFORMANCE MADE SMARTER Produktmanual 6331 2tråds programmerbar transmitter TEMPERATUR ExBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 6331V106DK Fra serienr.: 159740001 6
Læs mere2-tråds transmitter med HART -protokol. Nr. 5335V115-DK Fra serienr
5335 2tråds transmitter med HART protokol Nr. 5335V115DK Fra serienr. 120917001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mere2-tråds transmitter med HART -protokol. Nr. 5335V116-DK Fra serienr
5335 2tråds transmitter med HART protokol Nr. 5335V116DK Fra serienr. 120917001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereProduktmanual tråds transmitter med HART-protokol
Produktmanual 5337 2tråds transmitter med HARTprotokol PERFORMANCE MADE SMARTER TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY No. 5337V104DK Fra serienr.: 180971088
Læs mereProduktmanual tråds HART transmitter
Produktmanual 6335 2tråds HART transmitter PERFORMANCE MADE SMARTER TEMPERATUR ExBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 6335V111DK Fra serienr.: 150951186 6 produktområder
Læs mere2-tråds programmerbar transmitter. Nr. 6334V105-DK Fra serienr
6334 2tråds programmerbar transmitter Nr. 6334V105DK Fra serienr. 099256000 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereProduktmanual 6350 PROFIBUS PA / FOUNDATION Fieldbus Transmitter
Produktmanual 6350 PROFIBUS PA / FOUNDATION Fieldbus Transmitter PERFORMANCE MADE SMARTER TEMPERATUR ExBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 6350V104DK Fra serienr.:
Læs mereProduktmanual 5350 PROFIBUS PA / FOUNDATION Fieldbus Transmitter
Produktmanual 550 PROFIBUS PA / FOUNDATION Fieldbus Transmitter PERFORMANCE MADE SMARTER TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY Nr. 550V4DK Fra serienr.:
Læs merePROFIBUS PA / FOUNDATION Fieldbus transmitter. Nr. 6350V103-DK Fra serienr. 090449300
6350 PROFIBUS PA / FOUNDATION Fieldbus transmitter Nr. 6350V103DK Fra serienr. 090449300 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel
Læs mereProduktmanual tråds HART-transmitter
Produktmanual 6337 2tråds HARTtransmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY Nr. 6337V103DK Fra serienr.: 150950564 6 Produktområder
Læs mereProduktmanual 5802 Kompakt RTD temperaturtransmitter
Produktmanual 5802 Kompakt RTD temperaturtransmitter PERFORMANCE MADE SMARTER TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY Nr. 5802V100-DK Fra serienr.: 191043001
Læs mereProgrammerbar transmitter. Nr. 5131V104-DK Fra serienr.:
5131 Programmerbar transmitter Nr. 5131V104-DK Fra serienr.: 040112001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereProduktmanual tråds HART 7 temperaturtransmitter
Produktmanual 2-tråds HART temperaturtransmitter PERFORMANCE MADE SMARTER COMMUNICATION PROTOCOL TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. V0-DK Produktversion:
Læs mereMålestrømsforsynet isolator. Nr. 6185V100-DK Fra serienr
6185 Målestrømsforsynet isolator Nr. 6185V100-DK Fra serienr. 020271001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereProduktmanual tråds HART 7 temperaturtransmitter
Produktmanual 2-tråds HART temperaturtransmitter PERFORMANCE MADE SMARTER COMMUNICATION PROTOCOL TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. V102-DK Produktversion:
Læs mereHART -transparent driver. Nr. 5107V103-DK Fra serienr
5107 HART -transparent driver Nr. 5107V103-DK Fra serienr. 010454001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereWIO200A Water in oil sensor
WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic
Læs mereSensorer. Temperatur transmitter - Type 2211. Målskitse
4-20 ma transmitter for Pt100 følere, termokoblere, mv og indgang. Isolationsspændning 3,75 kv ac 2-vejs programmering via FlexProgrammer Nøjagtighed < (Pt100) Valgfri linearisering, dæmpning og tilstandsindikation.
Læs merePower Control Unit. Nr. 9410V101-DK Produktversion:
9410 Power Control Unit Nr. 9410V101-DK Produktversion: 9410-001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereWIO200A INSTALLATIONS MANUAL Rev Dato:
WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of
Læs mereProduktmanual 9410 Power control unit
Produktmanual 9410 Power control unit PERFORMANCE MADE SMARTER TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9410V103-DK Produktversion: 9410-001 6 produktområder
Læs mereUNISONIC TECHNOLOGIES CO.,
UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output
Læs mereTechnical Specifications
Technical Specifications Pressure measuring range (bar) 0.1... 0.5, (1) > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar > 200 bar Accuracy, (5), (± % FS)
Læs mereBilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).
Bilag 8. TDC technical requirements for approval of splitters and inline s intended for shared access (ADSL or VDSL over POTS). Dette bilag udgør bilag 8 til det mellem parterne tiltrådte Produkttillæg
Læs mereVentil- / alarmdriver. Nr. 9203V105-DK Produktversion: 9203-003
9203 Ventil- / alarmdriver Nr. 9203V105-DK Produktversion: 9203-003 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereProduktmanual 9113 Temperatur- / ma-konverter
Produktmanual 911 Temperatur- / ma-konverter PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 911V107-DK Produktversion: 911-004 6 produktområder
Læs mereTemperatur- / ma-konverter. No. 9113V105-DK Produktversion: 9113-004
911 Temperatur- / ma-konverter No. 911V105-DK Produktversion: 911-004 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereProduktmanual 9106B HART-transparent repeater
Produktmanual 9106B HARTtransparent repeater PERFORMANCE MADE SMARTER CCOE TEMPERATUR EXBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9106V105DK Produktversion: 9106002 6 produktområder
Læs mereProgrammerbar transmitter. Nr. 5114V106-DK Fra serienr
54 Programmerbar transmitter Nr. 5406DK Fra serienr. 9900600 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereDEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark.
CERTIFICATE Issued to: Applicant: ALIT S.r.l. ia Padania 6 20853 Biassono (MB) - ITALY Manufacturer/Licensee: ALIT S.r.l. ia Padania 6 20853 Biassono (MB) - ITALY Product(s) : Electronic controlgear for
Læs mereSM6001. Magnetisk-induktiv flowsensor. Made in Germany
Made in Germany Applikation Applikation totalisatorfunktion; til industriel anvendelse montering tilslutning til rørledning via adapter Medie Ledende væsker; vand; vandbaserede medier Medien ledningsevne:
Læs mereRepeater / Power Supply. No. 5104V104-DK Fra serienr SIGNALS THE BEST
5104 Repeater / Power Supply No. 5104V104DK Fra serienr. 030250001 SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel
Læs mereTransformator. Nr. 2240V101-DK Fra serienr
2240 Transformator Nr. 2240V101-DK Fra serienr. 970279001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs merePlug Connectors for Food & Beverage
Plug Connectors for Food & Beverage Made with stainless steel Food grade quality High protection degree MeeTS DEMANDING HYGIENIC STANDARDS The food and beverage industry needs an extremely clean environment
Læs mereProduktmanual 9203 Ventil - / alarmdriver
Produktmanual 9203 Ventil - / alarmdriver PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9203V107-DK Produktversion: 9203-003 6 produktområder
Læs mereProgrammerbar f/i - f/f konverter. Nr. 5225V101-DK Fra serienr
5225 Programmerbar f/i - f/f konverter Nr. 5225V101-DK Fra serienr. 970297001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereH07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:
Industrial flexible rubber cable range with an insulation and sheath in elastomers. Cables for heavy duty uses, Oil resistant and Flame retardancy according to IEC/EN 60332-1-2 standard. BESKRIVELSE Application
Læs mereDobbelt switchmode spændingsforsyning. Nr. 2223V101-DK Fra serienr
2223 Dobbelt switchmode spændingsforsyning Nr. 2223V101-DK Fra serienr. 970296001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel
Læs meremv-transmitter Nr. 2261V101-DK Fra serienr
2261 mv-transmitter Nr. 2261V101-DK Fra serienr. 970106001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereIsolationsforstærker. Nr. 2284V104-DK Fra serienr
2284 Isolationsforstærker Nr. 2284V104-DK Fra serienr. 970388001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereIntrinsically Safe Tablet PC
Intrinsically Safe Tablet PC Pad-Ex 01 HR DZ2 User s Manual Zone 2 / DIV 2 EN-1 1 We CAUTION FOR ADAPTER BATTERY SAFETY Relevant information for Ex-protection
Læs mereAFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf
JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color
Læs mereProgrammerbar f/i - I/f konverter. Nr. 5223B103-DK Fra serienr.:
5223 Programmerbar f/i - I/f konverter Nr. 5223B103-DK Fra serienr.: 040029001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereInstallationsvejledning P/N MMI , Rev. A September ATEX-installationsvejledning til Micro Motion MVD Direct Connect -målere
Installationsvejledning P/N MMI-20011736, Rev. A September 2008 ATEX-installationsvejledning til Micro Motion MVD Direct Connect -målere Bemærk: Ved montering i Europa i farlige områder henvises til standard
Læs mereSignalkalkulator. Nr. 5115V104-DK Fra serienr
5115 Signalkalkulator Nr. 5115104DK Fra serienr. 000395001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereAutomatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System
CERTIFICATE Panasonic Fire & Security Europe AB Jungmansgatan 12 SE 211 19 Malmö Sweden Certifikat nr. Certificate no. 232.258 har på baggrund af vurderede systemegenskaber baseret på systemprøvningsrapport(er)
Læs mereVarenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating
DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med
Læs mereProduktmanual 3100-serien 6 mm isolator- og konverterserie
Produktmanual 3100-serien 6 mm isolator- og konverterserie PERFORMANCE MADE SMARTER ZONE 2 Zone 2 ZONE 2 / DIV 2 CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS
Læs mereIndholdsfortegnelse. 9113 - Product Version 9113-003 1
9 1 1 T e m p e r a t u r - / m A - k o n v e r t e r N o. 9 1 1 V 1 0 - D K P r o d u c t v e r s i o n : 9 1 1-0 0 PENDING PENDING S I G N A L S T H E B E S T DK UK FR DE PR electronics A/S tilbyder
Læs mereSpændingsforsyning. Nr. 9420V100-DK Produktversion: 9420-102 FY26
9420 Spændingsforsyning Nr. 9420V100-DK Produktversion: 9420-102 FY26 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.
Læs mereInstallationsvejledning P/N MMI , Rev. A Februar ATEX installationsvejledning til Micro Motion model LFT, transmittere med lavt flow
Installationsvejledning P/N MMI-20011737, Rev. A Februar 2009 ATEX installationsvejledning til Micro Motion model LFT, transmittere med lavt flow Bemærk: Ved montering i Europa i farlige områder henvises
Læs mereTDC 4 Indoor voltage transformers
Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,
Læs mereProduktmanual 3185 Loop-forsynet isolator
Produktmanual 3185 Loop-forsynet isolator PERFORMANCE MADE SMARTER ZONE 2 Zone 2 ZONE 2 / DIV 2 CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 3185V101-DK
Læs mereProgrammable pressure transmitters PTM
Programmable pressure transmitters PTM Version: 07.01.2016 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure
Læs mereQuick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA
TekVor 1300C 1. Before You Begin This guide provides basic guidelines to assist you in quickly getting started. Installation of the transmitter in an explosive environment must be in accordance with the
Læs mereBrugervejledning. Xperia P TV Dock DK21
Brugervejledning Xperia P TV Dock DK21 Indholdsfortegnelse Indledning...3 Bagside oversigt over TV Dock...3 Kom godt i gang...4 Håndtering af LiveWare...4 Opgradering af Håndtering af LiveWare...4 Brug
Læs mereMFP-control. Temperaturstyret luftstrøm for Aircure-Units. Dansk Manual
MFP-control Temperaturstyret luftstrøm for Aircure-Units Dansk Manual Mogens Fredegaard Tinggaardsvej 2 5700 Svendborg Tlf. 6220 3323 Fax 6220 3324 Mail: mogens@fredegaard.dk www.fredegaard.dk Page 1 of
Læs mereLoop Link USB-kommunikations- Interface No. 5909V102-DK From ser. no
5909 Loop Link USB-kommunikations- Interface No. 5909V102-DK From ser. no. 059999999 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel
Læs mere6 m m i s o l a t o r- o g k o n v e r t e r s e r i e. M o d e l n r / / / / S I G N A L S T H E B E S T
3 1 0 0 6 m m i s o l a t o r- o g k o n v e r t e r s e r i e M o d e l n r. 3 1 0 3 / 3 1 0 4 / 3 1 0 5 / 3 1 0 8 / 3 1 0 9 N r. 3 1 0 0 V 1 0 6 - D K S I G N A L S T H E B E S T DK UK FR DE PR electronics
Læs mereSmartDock for Xperia ion Brugervejledning
SmartDock for Xperia ion Brugervejledning Indholdsfortegnelse Indledning...3 Oversigt over SmartDock...3 Opladning med SmartDock...3 Kom godt i gang...5 LiveWare -administration...5 Opgradering af LiveWare
Læs mereVentil- / alarmdriver. Nr. 9203V105-DK Produktversion:
9203 Ventil- / alarmdriver Nr. 9203V105-DK Produktversion: 9203-003 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet
Læs mereHi-Res Audio/DNC Headset MDR-NC750
Brugervejledning Hi-Res Audio/DNC Headset MDR-NC750 Indholdsfortegnelse Introduktion... 3 Introduktion...3 Oversigt... 3 De grundlæggende funktioner... 4 Sådan bærer du headsettet... 4 Tilslutning af dit
Læs mereRADARNIVEAUMÅLER SPECIEL SIKKERHEDSANVISNING
Speciel sikkerhedsanvisning da RADARNIVEAUMÅLER SPECIEL SIKKERHEDSANVISNING Indhold TankRadar Pro information om det europæiske ATEX-direktiv....................... 2 ATEX-mærkning og Ex-certificeringskode............................................
Læs merePEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation
PEMS RDE Workshop AVL M.O.V.E Integrative Mobile Vehicle Evaluation NEW - M.O.V.E Mobile Testing Platform Key Requirements for Measuring Systems Robustness Shock / vibrations Change of environment Compact
Læs mereBrugervejledning. MHL to HDMI Adapter IM750
Brugervejledning MHL to HDMI Adapter IM750 Indholdsfortegnelse Indledning...3 Oversigt over MHL to HDMI Adapter...3 Kom godt i gang...4 Smart Connect...4 Opgradering af Smart Connect...4 Brug af MHL to
Læs mereXperia TX TV Dock DK22 Xperia T TV Dock DK23
Brugervejledning Xperia TX TV Dock DK22 Xperia T TV Dock DK23 Indholdsfortegnelse Indledning...3 Oversigt over TV Dock...3 Kom godt i gang...4 Smart Connect...4 Opgradering af Smart Connect...4 Brug af
Læs mereProduktmanual 5202 Impulsisolator
Produktmanual 50 Impulsisolator PERFORMANCE MADE SMARTER TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY Nr. 50V100-DK Fra serienr.: 030481661 6 produktområder der
Læs mereWEA-Base Brugervejledning til vejetransmitter
WEA-Base Brugervejledning til vejetransmitter Version 3.4 WEA-Base Brugervejledning til vejetransmitter WEA-Base Brugervejledning til vejetransmitter Version 3.4 Indholdsfortegnelse 1. Tekniske data...
Læs mereuniversel isolation ex-interface temperatur display
P ro d u k t g u i d e universel isolation einterface temperatur S I G N A L S T H E B E S T display introduktion PR electronics A/S Siden PR electronics A/S blev grundlagt i 974, har virksomheden udviklet
Læs mereMetal Oxide Varistor:TVM-B Series
Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction
Læs mereProduktmanual 3000-serien 6 mm serie af temperaturkonvertere
Produktmanual 3000-serien 6 mm serie af temperaturkonvertere PERFORMANCE MADE SMARTER ZONE 2 Zone 2 ZONE 2 / DIV 2 TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY
Læs mere* _0817* Drivteknik \ Drivautomatisering \ Systemintegration \ Services. Rettelse. MOVIMOT MM..D med vekselstrømsmotor DT/DV
Drivteknik \ Drivautomatisering \ Systemintegration \ Services *23582529_0817* Rettelse MOVIMOT MM..D med vekselstrømsmotor DT/DV Udgave 08/2017 23582529/DA SEW-EURODRIVE Driving the world Supplerende
Læs mereIsolatorer & konvertere
Isolatorer & konvertere 3100-serien A d d i n g v A l u e t o f A c t o r y A n d p r o c e s s A u t o m A t i o n isolation display ex-interface temperatur universel Smal S erie med bred anvendelighed
Læs mereATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet.
ATEX direktivet Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet.dk tlf: 7220 2693 Vedligeholdelse af Certifikater / tekniske dossier / overensstemmelseserklæringen.
Læs mereUni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Elektrisk aktuator Electric actuator Tekniske data Technical data
Læs mereProduktmanual 5116 Programmerbar transmitter
Produktmanual 5116 Programmerbar transmitter PERFORMANCE MADE SMARTER TEMPERATUR EXBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 5116V105DK Fra serienr.: 181570001 6 produktområder
Læs mereInstallationsvejledning P/N MMI , Rev. A September ATEX-installationsvejledning til Micro Motion -transmittere model 2200
Installationsvejledning P/N MMI-20013044, Rev. A September 2008 ATEX-installationsvejledning til Micro Motion -transmittere model 2200 Bemærk: Ved montering i Europa i farlige områder henvises til standard
Læs mereWI180C-PB. Online-datablad
Online-datablad A B C D E F H I J K L M N O P Q R S T Oversigt over tekniske data Tekniske data Tilbehørsfamilie Henvisning Kapslingsklasse Dimensioner (B x H x L) Beskrivelse Klassifikationer Bestillingsoplysninger
Læs mereCO2 Control Box E-Cab-980
CO2 Control Box E-Cab-980 CO2 Control Box E-Cab-980 er beregnet til detektering og alarmereing ved utætheder i CO2 køleanlæg i køle- og fryserum. CO2 Control Box E-Cab-980 er designet til at fungere sammen
Læs mereProduktmanual 3117 Bipolar isolator konverter
Produktmanual 3117 Bipolar isolator konverter PERFORMANCE MADE SMARTER ZE 2 Zone 2 ZE 2 / DIV 2 CCOE TEMPERATUR I.S. INTERFACES KOMMUNIKATISINTERFACES MULTIFUNKTIEL ISOLATI DISPLAY Nr. 3117V01-DK Fra serienr.:
Læs mereKomplet køreklar 6000 W Solcelle anlæg. Kr. 122.400,- inkl. moms
Indeholder komplet system: Komplet køreklar 6000 W Solcelle anlæg Kr. 122.400,- inkl. moms 24 stk 250 W Monocrystalinske Full Black Solpaneler (ca.41m 2 ) 2 stk Dansk godkendte 3000 W Invertere med 10
Læs mereKomplet køreklar 3000 W Solcelle anlæg. Kr. 71.400,- inkl. moms
Indeholder komplet system: Komplet køreklar 3000 W Solcelle anlæg Kr. 71.400,- inkl. moms 12 stk 250 W Monocrystalinske Full Black Solpaneler (ca.20m 2 ) 1 stk Dansk godkendt 3000 W Inverter Diskret Full
Læs mereMFP-control. Temperaturstyret luftstrøm for Aircure-Units. Dansk Manual
MFP-control Temperaturstyret luftstrøm for Aircure-Units Dansk Manual Mogens Fredegaard Tinggaardsvej 2 5700 Svendborg Tlf. 6220 3323 Fax 6220 3324 Mail: mogens@fredegaard.dk www.fredegaard.dk Page 1 of
Læs mereInstallationsvejledning P/N MMI , Rev. AA Juli ATEXinstallationsvejledning. Micro Motion transmittere, model 9701/9703
Installationsvejledning P/N MMI-20011735, Rev. AA Juli 2009 ATEXinstallationsvejledning til Micro Motion transmittere, model 9701/9703 Bemærk: Ved montering i Europa i farlige områder henvises til standard
Læs mereSide 1. Page 15. Page 29. Seite 43. PROFIBUS PA / FOUNDA- TION Fieldbus Transmitter SIGNALS THE BEST
Isolation Galvanic isolators for analogue and digital signals as well as HART signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling
Læs mereFarvekoder på vejeceller leveret af NTT fra 2017
Farvekoder på vejeceller leveret af NTT fra 2017 Betegnelser: Forsyning til vejecellen kan være kaldt +/ -Excitation, Exc., In +/-, Input m.m. Signal fra vejecellen kan betegnes: Signal +/-, out +/-, output
Læs mereSOT-363 Plastic-Encapsulate Transistors
JIANGSU CHANGJING ELECTRONICS TECHNOLOGY CO., LTD SOT-363 Plastic-Encapsulate Transistors UMZ2N DUAL TRANSISTOR (PNP+NPN) FEATURES Both 2SA37AK and 2SC242K chip in a package Transistor elements are independent,
Læs mereCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that Wilmington Instrument Company, Inc. 332 North Fries Avenue Wilmington,
Læs mereProduktmanual 5116 Programmerbar transmitter
Produktmanual 5116 Programmerbar transmitter PERFORMANCE MADE SMARTER TEMPERATUR EXBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 5116V104DK Fra serienr.: 181570001 6 produktområder
Læs mereOG-3600 Series Fiber Optic Transport for opengear card frame platform w/ SNMP Management
FEATURES w w 4 HDSDI 3G 8x8 Line/AES Genlock Time Code, GPIO, Data APPLICATIONS Studio Links Signal Trunking Signal distribution Campus interconnects Transmission links Telco circuits w w Outside Broadcast
Læs mere