1 Side 1 Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2

2 Side 2 Indholdsfortegnelse 1. MENUSTRUKTUR - OVERORDNET MENU-TRÆ BRUGERMENU INFORMATION KEDELINDSTILLINGER ANLÆGSINDSTILLINGER Sommer VV indstillinger VV cirkulation indstillinger Blandekredsindstillinger DIVERSE INDSTILLINGER TEST UDGANGE ALARMER INSTALLATØRMENU KEDELINDSTILLINGER Røgsuger indstillinger Røggastemperatur indstillinger Kedeltemperatur indstillinger Iltsensor ANLÆGSINDSTILLINGER Kedelpumpe funktion VV indstillinger Blandekreds 1 indstillinger Blandekreds 2 indstillinger LAGERTANKSINDSTILLINGER FUNKTIONER VARMTVANDSFUNKTION RETURTEMPERATUR BESKYTTELSE VIA BLANDEKREDS LAGERTANKSFUNKTION BLANDEKREDS PAV MAX ÅBNING (FORPUFNINGER) EKSTRA KEDEL OPKOBLING AF ELFORBINDELSER Indholdet i denne manual kan blive ændret uden forvarsel fra leverandørens side.

3 STYRINGS Side 3 1. Menustruktur - overordnet TPK HS20/TPK HS20 LC styringen er opdelt i 3 lag. Første lag er hoveddisplayet. Her gives summariske oplysninger om den øjeblikkelige driftssituation. Ved at dreje på dreje-tryk knappen skiftes mellem forskellige basale oplysninger om driften:

4 Side 4 Andet lag er Brugemenuen. Denne nås ved at trykke på Menu symbolet på styringen. Drej på dreje-tryk knappen for at scrolle op og ned blandt de tilgængelige parametre. Trejde lag er Installatørmenuen. Denne nås ved at vælge Installatørmenu i Brugermenuen. Her dukker indtastning af PIN-kode op som et lille vindue. Tastes blot 0000, gives adgang til at se parameterne i Installatørmenuen, men uden mulighed for at ændre noget: I øverste venstre hjørne ses en et hængelås-symbol. Dette indikerer den låste tilstand. Hvis der i stedet tastes koden 2003 (værdier skiftes med dreje-tryk knappen kvittering ved tryk), fås fuld adgang til at læse og ændre parameterværdier, og hængelåssymbolet forsvinder. Parameterne i henholdsvis Brugermenu og Installatørmenu er en blanding af direkte adgang til ændring af en enkelt parameter og yderligere undermenuer med flere parametre. I de følgende afsnit er alle menuer vist. Ikke alle menuer er tilgængelige for alle kedler. Styringen erkender automatisk tilkoblede ekstraudstyr, og aktiverer menuer i relation hermed.

5 Side Menu-træ Menu-træet foldes ud i forbindelse med gennemgangen af parametre og menuer i de efterfølgende afsnit.

6 Side 6 2. Brugermenu Undermenu Hvad er dette? Information Forskellige vinduer med informationer om status og drift Kedelindstillinger Indstilling af sætpunkt og valg af brændselstype Iltsensor kalibrering Kalibrering af iltsensor (påkrævet hver 1500 driftstime) Anlægsindstillinger Indstillinger for anlægget (sommer/vinter, blandekredse osv.) Test udgange Test af udgange: røgsuger, spjæld osv. Diverse indstillinger Sprog, display kontrast og lys, WiFi osv. Alarmer Liste over alarmer Installatørmenu Adgang til Installatørmenu (PIN-kode: 2003)

7 Side Information Antallet af informationsvinduer afhænger af, hvor meget udstyr, der er tilsluttet styringen. Fx vil tilslutning af en blandekreds give endnu et informationsvindue, hvor relevante oplysninger herom gives.

8 Side Kedelindstillinger Kedeltemperatur Sætpunkt for kedeltemperaturen C Brændselstype Forvalg af brændselstype Tørt hårdt træ, hårdt træ, tørt nåletræ, nåletræ Valg af brændselstype giver forindstilling af maksimale åbningsgrad for primær luftspjældet. Det er vigtigt, at primær luftspjældet er begrænset i sin åbningsgrad især ved meget tørre brændsler (<12 % RH). Tørt hårdt træ: <15 % RH Hårdt træ: <25 % RH Tørt nåletræ: <15 % RH Nåletræ: <25 % RH Hårdt træ

9 Side Anlægsindstillinger Sommer Indstilling af funktioner for anlægget ved sommer tilstand Undermenu VV indstillinger Indstillinger af varmt vandsfunktionen Undermenu VV circulation indstil. Indstillinger for varmtvandscirkulationsfunktionen Undermenu Blandekreds Indstillinger for blnadekreds(e) indstill. Undermenu

10 Side Sommer Mode Funktionsmåde ved sommerdrift OFF, ON, AUTO OFF Akt. temp. Udetemperatur ved hvilken sommerdrift aktiveres (hvis Mode = AUTO) C Deakt. temp. Udetemperatur ved hvilken sommerdrift deaktiveres (hvis Mode = AUTO) 1 Akt. temp C VV indstillinger VV temp. sætp. 1 ) Varmtvandstemperatur sætpunkt C VV pumpe mode Aktivering af pumpe, valg af prioritrering OFF, ingen prioritet, prioritet 2 OFF ) VV hysterese Antal grader lavere end sætpunktet, hvor VV funktion starter C Tidsintervaller Indstilling af intervaller for VV produktion OFF, ON -> Hverdage, lørdage, søndage 3 ) 1 ) Funktion kun tilgængelig hvis Udgang funktion (Installatørmenu) er valgt til Varmtvandspumpe. 2 ) Ved prioritet stoppes anlægspumper under varmtvandsproduktion (inkl. kedelpumpe), men kun hvis Lagertankssystem er sat til OFF. 3 ) Ved aktivering af intervaller (ON), give mulighed for indstilling af op til 3 daglige intervaller, hvor VV temperaturen kan sænkes med et antal grader VV cirkulation indstillinger Cirk.OFF.time. 1 ) Tidperiode hvor cirkulationspumpen står stille C Cirk.ON.time Tidsperiode hvor cirkulationspumpen kører OFF, prioritet, ingen prioritet 2 ) OFF Start temperatur Antal grader lavere end sætpunktet, hvor VV funktion starter C Tidsintervaller Indstilling af intervaller for VV cirkulation OFF, ON -> Hverdage, lørdage, søndage 3 ) Blandekredsindstillinger Fremløbstemp. Indstilling af fremløbstemperatur 1 ) 2 ) 2 ) 3 ) Rumtermostat Indstillinger for rumtermostat Undermenu Vejrkompensering Indstillinger for vejrkompensering Undermenu Tidsintervaller Indstilling af intervaller for blandekreds cirkulation OFF, ON -> Hverdage, lørdage, søndage 4 ) 1 ) Kun mulig hvis udetemperaturstyring er slået fra. 2 ) Afhænger af indstilling af min og max temperaturer indstillet i Installatørmenu 3 ) Afhænger af valgt anlægstype 4 ) Indstilling af 3 intervaller for hver gruppe er mulig; hvert af de 3 intervaller kan indstilles med hver sin ændring af ønsket fremløbstemperatur.

11 Side Rumtermostat Termostat support Aktivering af termostatfunktion OFF ON OFF Red. fremløbstemp. Reduktion af fremløbstemperaturen når term. termostat lukker C Rumtemperaturfaktor Rumtemperaturens indflydelse på fremløbstemperaturen ) 1 ) Korrektion af fremløbstemp. = (Ønsket rumtemp. faktisk rumtemp.)*(rumtemp.faktor/10) Vejrkompensering Udetemp.styr.blandekreds Aktivering af udetemperaturstyring OFF ON OFF Varmekurve Valg af ønsket varmekurve blandekreds 0,1 4,0 0,8 Kurveforskydning Parallelforskydning af valgte varmekurve C 1 ) 1 ) Indirekte forskydning: indstillingen simulerer en ønsket ændring i rumtemperaturen.

12 Side Diverse indstillinger Tid Indstilling af ur og dato - Display lysstyrke Indstilling af displayets lysstyrke % Display kontrast Indstilling af displayets kontrast % Lyd Aktivering af lydfunktioner OFF, ON, ON 6:00-22:00 Sprog Aktivering af ønsket sprog i displayet - WiFi Indstillinger for WiFi Der henvises til manualen for econet

13 STYRINGS 2.5 Side 13 Test udgange Listen over udstyr til output-test afhænger af aktuelle tilslutninger. Hvert af de tilsluttede output kan testes ved at sætte dem ON. Alle sættes automatisk OFF igen, når menuen forlades. 2.6 Alarmer Op til i alt 100 alarmer gemmes i styringen. Man scroller mellem de forskellige alarmer ved at dreje på dreje-tryk knappen. Alarmvinduet giver informationer om alarmens type og/eller årsag, tidspunktet hvor alarmen indtraf, og hvor den igen er ophævet.

14 Side Installatørmenu Undermenu/parameter Kedel indstillinger Anlægsindstillinger Lagertanksindstillinger Udgang funktion Fabriksindstillinger Servicemenu Hvad er dette? Temperaturer, røgsuger indstillinger, iltstyring osv. Centralvarmeindstillinger, VV indstillinger, blandekredse osv. Valg af lagertanksanlæg, indstilling af temperaturer osv. Valg af funktion for udgang 20-21; varmtvandsproduktion eller 3-vejs ventil for anlægsprioritering Tilbagestilling til parameterindstillinger ved levering Ingen adgang (kode)

15 Side Kedelindstillinger Parameter/undermenu Forklaring Min Max Default Røgsuger indstillinger Parametre for røgsugeren Undermenu Røggastemperatur indst. Parametre for røggastemperaturen Undermenu Kedeltempertaur indst. Parametere for kedeltemperaturen Undermenu Udbrændingstid Efterløb for røgssuger og kedelpumpe efter stopbetingelser er opfyldt min Ekstrakedel mode Aktivering og valg af typen af ekstrakedel OFF, gas/olie OFF kedel, biomasse kedel Ekstrakedel type Valg af om ekstrakedel er ekstern kedel, eller fx brænder monteret på Integreret, ekstern Ekstern hovedkedlen Iltstyring Indstillinger for iltstyring Undermenu 3.1.4

16 Side Røgsuger indstillinger Min. hastighed Indstilling af røgsugerens minimal hastighed ) Max. hastighed Indstilling af røgsugerens maksimale hastighed ) Optændingshastig. Indstilling af røgsugerhastigheden ved optænding ) Genfyldningshast. Indstilling af røgsugerhastighedens forøgelse 20 i forhold til maks. ved genfyldning % 1 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 30 %; Solo Innova 30 LC MK2: 30 %; Solo Innova 50 LC MK2: 50 % 2 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 45 %; Solo Innova 30 LC MK2: 45 %; Solo Innova 50 LC MK2: 70 % 3 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 60 %; Solo Innova 30 LC MK2: 60 %; Solo Innova 50 LC MK2: 90 % Røggastemperatur indstillinger Røggastemp. Sætpunktet for røggastempertur = aktuel delta kedeltemperatur + røggastemp. delta ) Min. røggastemp. Udbrænding kan starte, når røggastemperaturen bliver mindre end denne værdi C 1 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 65 C; Solo Innova 30 LC MK2: 65 ; Solo Innova 50 LC MK2: 50 C Kedeltemperatur indstillinger Min. kedeltemp. Minimum indstillelig kedeltemperatur i Bruger menu Max. kedeltemp Maksimum indstillelig kedeltemperatur i Bruger menu C C Kedel alarmtemp. Alarmtemperatur for kedlen C Iltsensor Iltsensor funktion Aktivering af iltstyringsfunktion OFF ON ON Sætpunkt ilt Indstilling af sætpunkt for iltprocent % Max. ilt (udbrænd.) Indstilling af max. iltprocent hvor udbrænding starter % Optænd.max.tid Maksimale optændingstid (røgtemp. > min) min Min. PAV Min. PAV under drift % Max. PAV tørt hårdt Max. PAV under drift med tørt hårdt træ træ ) Max. PAV hårdt træ Max. PAV under drift med normalt hårdt træ ) Max. PAV tørt blødt Max. PAV under drift med tørt nåletræ træ ) Max. PAV blødt træ Max. PAV under drift med normalt nåletræ ) 1 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 30 %; Solo Innova 30 LC MK2: 30 %; Solo Innova 50 LC MK2: 50 % 2 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 45 %; Solo Innova 30 LC MK2: 45 %; Solo Innova 50 LC MK2: 70 % 3 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 60 %; Solo Innova 30 LC MK2: 60 %; Solo Innova 50 LC MK2: 90 % 4 ) Værdi afhænger af kedeltypen: Bonus 30 LC: 60 %; Solo Innova 30 LC MK2: 60 %; Solo Innova 50 LC MK2: 90 %

17 Side Anlægsindstillinger Parameter/undermenu Forklaring Min Max Default Kedelpumpe funktion Indstillinger for kedelpumpefunktionen Undermenu VV indstillinger Indstillinger for VV produktion Undermenu VV cirkul. indstillinger Aktivering af VV cirkulation OFF ON OFF Blandekreds 1 indstil. Indstillinger for blandekreds 1 Undermenu Blandekreds 2 indstil. Indstillinger for blandekreds 2 Undermenu 3.2.4

18 Side Kedelpumpe funktion Stop v. VV Varighed af stop af kedelpumpe ved VV produktion produktion min ) Kedelpumpe Indstilling af funktion for kedelpumpe 1 ) OFF, ON, funktion Varmeveksler 2 ON ) 1 ) Funktion kun til rådighed, hvis Lagertankssystem er sat til OFF og har kun funktion, hvis VV pumpe mode er sat til Prioritet 2 ) Ved valg af Varmeveksler kører kedelpumpen kontinuert VV indstillinger Forøgning Hævning af kedeltemperaturen ved VV kedeltemp. VV produktion C Max VV Indstilling af den maksimalt mulige indstilling 25 temperaturen af VV temperaturen i Bruger menuen C Forlæng. drift VV Fortsat drift af VV pumpe efter at sætpunktet pumpe for VV er nået 1 0 ) 99 0 min. 1 ) Funktion kun til rådighed, hvis Lagertankssystem er sat til OFF Blandekreds 1 indstillinger Blandekreds support Aktivering og funktion af blandekreds Off, Anlæg ON, Gulv ON, Pumpe alene Gulv ON Termostat valg Valg af termostattype Universal, ecoster 1 ) Min. blandekreds Indstillelig minimum temperatur i Bruger temp. menuen ) Max. blandekreds Indstilelig maksimum temperatur i Bruger temp. menuen ) Ventils åbningstid Ventilens åbningstid fra o til 100 % åben sek. Pumpestop Angivelse af, om pumpen skal stoppe når termostat termostaten ikke kalder på varme. Nej Ja Ja Sommerdrift Aktivering af sommerdrift for blandekredsen OFF ON ON Blandeventil Interval omkring sætpunkt, hvor der ikke sker 0 dead-zone nogen regulering. 4 0,5 C 1 ) Afhænger af tilslutninger 2 ) Afhænger af valg under Blandekreds support

19 Side Blandekreds 2 indstillinger Blandekreds Aktivering og funktion af blandekreds support Off, Anlæg ON, Gulv ON, Pumpe alene, Ked. retur beskyttel. ) Termostat valg Valg af termostattype Universal, ecoster 2 ) Min. blandekreds Indstillelig minimum temperatur i Bruger temp. menuen Max. blandekreds Indstilelig maksimum temperatur i Bruger temp. menuen Ventils åbningstid Ventilens åbningstid fra o til 100 % åben ) ) Gulv ON Pumpestop Angivelse af, om pumpen skal stoppe når Nej Ja Ja termostat termostaten ikke kalder på varme. Sommerdrift Aktivering af sommerdrift for blandekredsen OFF ON ON Blandeventil Interval omkring sætpunkt, hvor der ikke sker 0 4 0,5 C dead-zone nogen regulering. 1 ) Blandekreds 2 kan anvendes til styring af pumpe og 3 vejs shuntmotor for returtemperaturbeskyttelse af kedlen 2 ) Afhænger af tilslutninger 3 ) Afhænger af valg under Blandekreds support 140 sek.

20 Side Lagertanksindstillinger

21 Side 21 Lagertankssystem Valg af lagertankssystem se Anlægsmanual OFF Max. lagertankstemp. Min. lagertankstemp. Start hyst. pumpe 1 ) Stop hyst. pumpe 1 ) Indstilling af temperaturen ved topsensoren i den primære lagertank (T1 eller T2) Indstilling af minimumtemperaturen i lagertanken, som bestemmer aktivering af ekstern varmekilde Maximum temperaturforskel mellem tanke. Hvis forskellen er større end denne temperaturforskel, starter hhv. den ene eller den anden lagertanksfpumpe Minimum temperaturforskel mellem tanke. Hvis forskellen er mindre end denne temperaturforskel, stopper hhv. den ene eller den anden lagertankspumpe OFF, System 1 (T1), System 2 (T1), System 3 (T2) C C C 1 Start 1 2 C Overskudsvarme Aktivering af overskudsvarme funktion OFF ON OFF Max lagertank temp. Ekstra kedel stop hysterese 2 ) Restvarme kedelp. start Restvarme kedelp. stop Anlægsstop min. temp. Overskudsvareme: Ved overskridelse af denne temperatur tvangsåbnes alle forbrugere (varmekredse, VV produktion osv.) Hvis Ekstra kedel funktionen er aktiveret, indstilles her temperturforskellen mellem Max. lagertankstemp. og stop af ekstra kedel Restvarmefunktion. Denne flytter restvarme fra kedlen til lagertanken, efter at forbrændingen i kedlen er overstået. Hvis kedeltemperaturen er er mere end denne forskel større end lagertankstemp., starter kedelpumpen igen. Restvarmefunktion. Denne flytter restvarme fra kedlen til lagertanken, efter at forbrændingen i kedlen er overstået. Hvis kedeltemperaturen er er mindre end denne forskel større end lagertanktemp., stopper kedelpumpen igen. Anlægspumperne stopper, hvis lagertankstemperaturen bliver mindre end denne C C C 1 Start-3 2 C C Zoneventil 3 ) Aktivering af zoneventil funktion OFF ON ON Zoneventil Ved lagertanktemp. lavere end denne temperatur 3 ) 4 ) skifter zoneventil til top/center af tank C Zoneventil hysterese 3 ) 4 ) Ved lagertanktemp. højere end denne temperaturforskel over sætpunkt, skifter C zoneventilen tilbage til bunden af tanken. 1 ) Parametrene er kun tilgængelige 2 ) Funktion er kun tilgængelig, hvis Ekstra kedel mode er sat til enten Olie/gas eller Biomasse kedel. 3 ) Funktion kun tilgængelig, hvis Udgang er sat til Zoneventil 4 ) Er kun tilgængeloge hvis Zoneventil er sat til ON.

22 Side Funktioner Mange af parametrene i styringen er forklaret i de foregående afsnit. I de efterfølgende afsnit gives en gennemgang af udvalgte funktioner, hvor mulighederne enten er flere eller mere komplicerede. 4.1 Varmtvandsfunktion Primær funktion: Varmtvandsfunktionen anvendes normalt kun sammen med System 1 og System 2, men kan i princippet også anvendes sammen med System 3. Forudsætningen for, at funktionerne i styringen fungerer efter hensigten er, at anlægget er opbygget i henhold til et af de installationsdiagrammer, som forefindes i Anlægsmanualen. Er installationen lavet efter et af de angivne installationsdiagrammer, kan energien til opvarmning af varmtvandsvandsbeholderen komme fra enten kedlen eller lagertanken. Energi fra kedlen: Hvis lagertankene er kolde, og kedlen er startet op, og kedeltemperaturen er højere end aktiveringstemperaturen for kedelpumpen, vil varmtvandpumpen starte, når kedeltemperaturen er højere end den aktuel varmtvandstemperatur (som selvfølgelig skal være mindre end sætpunktet for varmt vand). Energi fra lagertanken: Hvis kedlen er stoppet (eller kold), og lagertankstemperaturen en højere end aktuel varmtvandstemperatur, starter varmtvandspumpen, hvis den aktuelle varmtvandstemperatur er lavere end sætpunktet for varmt vand. Sekundære funktioner: Forlænget drift af varmtvandspumpen: Hvis det er ønskeligt, at varmtvandspumpen fortsætter opvarmningen af varmtvandsbeholderen en periode efter at sætpunktet er nået, indstilles dette med parameteren Forlæng. drift VV pumpe (Installatør menu/anlægsindstillinger/vv indstillinger). Funktionen er kun mulig, hvis Lagertanks support er sat til OFF. Varmtvandscirkulation: Hvis varmtvandssystemet er udstyret med cirkulation, kan dette også håndteres af styringen. Reguleringen fungerer som en timer-regulering, dvs. driften af VV-cirkulationspumpen sker efter en programmeret køretid og en pausetid. Ligeledes kan der indstilles en minimum VV temperatur for drift af cirkulationssystemet. Yderligere kan der ved hjælp af parameteren Tidsintervaller indstilles 3 uafhængige perioder per døgn for hverdage, lørdag og søndag. Dvs. man kan programmere i hvilke perioder VV-cirkulationen er aktiv, og i hvilke perioder funktionen ikke er aktiv. OBS: vær opmærksom på, at man ikke kan have både varmtvandsproduktion og zoneventil for anlægsprioritering styret på én gang. De 2 forskellige funktioner bruger den samme udgang. Valget mellem de 2 funktioner foretages med parameteren Udgang funkton (Installatør menu).

23 Side Returtemperatur beskyttelse via blandekreds 2 Hvis man ønsker at anvende en motorstyret 3-vejs ventil (3-punkts motor) og en pumpe i stedet for en ladekreds, kan man anvende blandekreds 2 s hardware til dette. Under parameteren Blandekreds support for blandekreds 2, vælges Ked. retur beskyttel. Fremløbsfølerindgangen (terminal 26-27) anvendes til en returtemperaturføler, som placeres i strengen mellem 3-vejs ventilen og kedlen. Kedelpumpen tilsluttes stadig kedelpumpeudgangen (terminal 8-9). 3-vejs ventilens motor tilsluttes terminal Lagertanksfunktion Lagertanksfunktionen afhænger grundlæggende af, hvilket af de 3 systemer, der valgt. For at funktionerne i styringen skal fungere optimalt, er det vigtigt at det enkelte system er opbygget i henhold til et af de installationsdiagrammer, som forefindes i Anlægsmanualen. OBS: Hvis der ikke er valgt noget system (OFF), vil flere funktioner ikke som normalt være afhængig af temperaturforholdene i lagertanken(e), fx vil produktion af varmt vand være afhængig af kedeltemperaturen alene, og ikke som normalt af enten kedeltemperaturen eller largertankstemperaturen. Anvendelse af zoneventil: Til prioritering af varme til anlægget, kan der anvendes en 3-vejs zonevetil, som skifter mellem at tage hele lagertanksvolument med eller kune en del af det. På denne måde kan man undgå at slæbe hele den kolde bund med i opvarmningen, hvorved der hurtigere kan opnås en højere temperatur i den øvre del af lagertanken. Anlægsprioriteringsfunktionen kan i øvrigt anvendes i alle 3 systemer. OBS: vær opmærksom på, at man ikke kan have både varmtvandsproduktion og zoneventil for anlægsprioritering styret på én gang. De 2 forskellige funktioner bruger den samme udgang. Valget mellem de 2 funktioner foretages med parameteren Udgang funkton (Installatør menu). System 1: I dette system fungerer alle tanke (1 eller flere) som om det var et sammenhængende volumen. Dvs. der er ikke nogen interaktion mellem flere tanke (som i System 2 eller 3). Alle reguleringer baseres på topføleren (T1) i tanken(e).

24 Side 24 System 2: I dette system forudsættes det at der anvendes(minimum) 2 lagertanke en primær tank og en sekundær tank. Kedlen (og anlægget) er kun forbundet direkte med den primære tank. Den sekundære tank anvendes til lagring af overskudsvarme, der ved behov flyttes tilbage til primær tanken. Flytningen af energi foretages ved hjælp af 2 pumper, der henholdsvis flytter vand fra bunden af den ene tank til den og visa versa. Alle reguleringer baseres på topføleren (T1) i primær tanken og føleren i toppen af sekundær tanken (T4). System 3: I dette system forudsættes det at der anvendes(minimum) 2 lagertanke en primær tank og en sekundær tank. Primær tanken forudsættes at indeholde en brugsvandstank. Produktionen af brugsvand er prioriteret. Øvrig funktion af systemet er som System 2. Alle reguleringer baseres på føleren placeret ved bunden af varmtvandsbeholderen (T2) i primær tanken og føleren i toppen af sekundær tanken (T4). Funktion af lagertankspumper System 2 og 3: Pumperne styres med udgangspunkt i indstillingen af Max. lagertankstemp. Sammen med parametrene Start hyst. pumpe og Stop hyst. pumpe, startes henholdsvis pumpen, der flytter energi fra primær tanken til sekundær tanken og omvendt. Når temperaturen ved T1 for System 2 eller ved T2 for System 3 bliver højere end Max. lagertanktemp. og det samtidig gælder, at (aktuel temperatur ved T1 eller T2 minus Start hyst. pumpe) er større end aktuel temperatur ved T4, starter pumpen tilsluttet udgang 7-8 (fra primær tank -> sekundær tank symbol: ). Når temperaturen ved T4 bliver højere end (Aktuel lagertanktemp. ved T1 eller T2 + Start hyst. pumpe), starter pumpen tilsluttet udgang 6-7 (fra sekundær tank -> primær tank symbol:. Pumperne stopper igen, når temperaturforskellen igen bliver lavere end Stop hyst. pumpe. Overskudsvarme: Når funktionen overskudvarme er aktiveret (ON), bortledes energi fra tankene, når temperaturen ved T1 overskrider værdien af Max. lager temp. (default 98 C). Funktionen kan bruges fx i forbindelse med tilslutning af solvarmesystem til lagertankene. Ved overskridelse af maksimal tempeaturen (default 98 C), tvangsåbnes alle forbrugere (pumpekredse, blandekredse osv.). Dog åbnes blandekredsene ikke 100 %, men vil køre normalfunktionen, dvs. maksimale fremløbstemperatur indstilling for blandekredsen vil forblive overholdt.

25 Side 25 Restvarme fra kedel: Når forbrændingen i kedlen er gennemført (røgsuger og pumpe stoppet), stiger temperaturen igen i kedlen. Dette skyldes varmeenergi oplagret i keramiksættet. Denne restvarem kan delvist udnyttes ved hjælp af restvarmefunktionen, der igen starter kedelpumpen, når temperaturen i kedlen har nået en passende høj temperatur i forhold til temperaturen i toppen af lagertankene. Parameteren Restvarme kedelp. start bestemmer hvor meget højere kedeltemperaturen skal være i forhold til temperaturen i toppen af lagertanken, før kedelpumpen starter. Parameteren Restvarme kedelp. stop bestemmer hvornår pumpen skal stoppe igen. OBS: kedelpumpen stopper altid, hvis kedeltemperaturen bliver mindre end 58 C. Minimum lagertankstemperatur for stop af anlægspumper: Parameteren Anlægsstop min. temp. bestemmer hvor lav fremløbstemperaturen til anlægget fra lagertankene må blive. Dvs. hvis temperaturen i lagertankene bliver mindre end denne temperatur, stopper anlægspumperne. 3-vejs zoneventil: Zoneventilfunktionen anvendes til at prioritere varme til anlægget. Dette gøres ved at by-passe en del af lagertanksvolumet under opstart af kedlen. Dvs. når lagertankstemperaturen (System 1 og System 2: T1, System 3: T2) bliver mindre end den indstillede temperatur via parameteren Zoneventil temperatur skifter zoneventilen fra retur til bunden af lagertankene til midten (eller andet sted længere oppe på tanken). Når temperaturen bliver højere end (Zoneventil temperatur + Zoneventil hysterese) skifter ventilen tilbage til bunden af lagertankene. Der henvises i øvrigt til Anlægsmanualen mht. korrekt installation af zoneventilen. 4.4 Blandekreds Kedlens styring er forberedt for tilslutning af to udetemperaturstyrede blandekredse. Når en fremløbsføler monteres i styringen (se afsnit 5), aktiveres/vises de relevante menuer for tilpasning af blandekredsens funktioner. Blandekredsen bygges af en motorstyret 3-vejsventil og en fremløbspumpe. 3-vejs ventilen skal have en såkaldt 3-punkts motor, 230 VAC. 2 faser styrer hhv. højre og venstre drejning af ventilens aksel. Korrekt tilslutnings skal tjekkes hvis ventilen drejer i den modsatte retning af forventet, ombyttes blot tilslutningen af de to faser. For korrekt funktion af 3-vejsventilen, skal styringen programmeres med relevante oplysninger for denne: Åbnetid for blandeventil (se afsnit 3.5.2) o Dette er den tid i sekunder, som ventilen kræver for at åbne fra 0 til 100 % åben. o Styringen kan håndtere ventiler med åbningstider fra 10 til 255 sekunder. Dæmpning (dead-zone) (se afsnit 3.5.2) o For at ventilen ikke skal ligge og pendle hele tiden, vælges en passende zone omkring den ønskede fremløbstemperatur, hvor styringen ikke regulerer ventilens position. o Fabriksindstillingen på 2 C giver en rolig ventil, men vil tillade en variation på +/- 2 C i fremløbstemperaturen.

26 Side 26 Valg af blandekredstype: I styringen vælges hvilket varmesystem blandekredsen skal styre: ren pumpekreds, radiatorkreds eller gulvarmekreds. Valget begrænser den maksimalt mulige fremløbstemperatur ved gulvarmekreds stopper pumpen, hvis fremløbstemperaturen overskrider 55 C. Min. blandekreds temp. og Maks. blandekreds temp. indstilles for hver blandekreds se afsnit Hvis der er valgt drift uden udetemperaturføler (ikke tilsluttet eller frastillet) vil indstillingerne her begrænse indstillingsintervallet i Brugermenu/Anlægsindstillinger/Blandekreds/Fremløbstemperatur. Hvis der er valgt drift med udetemperaturkompenseret fremløbstemperatur (udeføler monteret og aktiveret), vil indstillingerne af Min. blandekreds temp. og Maks. blandekreds temp. sikre, at temperaturen i blandekredsen bliver i dette interval, selv om den valgte Varmekurve (se afsnit 2.5.4) måtte foreskrive en temperatur uden for intervallet. OBS: kedlens styring kan ikke anvendes som sikring mod for høj fremløbstemperatur. Hvis anlægget især gulvvarmesystemer har en foreskrevet maksimal temperatur, skal dette sikres på anden måde. Varmekurver (se afsnit 2.5.4): Den valgte varmekurve styrer fremløbstemperaturen i blandekredsen i afhængighed af udetemperaturen. Generelt jo koldere udenfor, jo højere fremløbstemperatur. Den valgte varmekurve (0,1 4,0) styrer stigningsgraden i fremløbstemperaturen ved faldende udetemperatur. Typiske valg af varmekurve for forskellige anlægstyper: Radiatorkreds: 1,0 1,6 Gulvvarmekreds: 0,2 0,6 Lagertank: 1,8 4,0

27 Side 27 Individuelle tilpasninger kan være nødvendige. Tips: Hvis rumtemperaturen stiger, når udetemperaturen falder, er der valgt en for høj værdi for varmekurven. Hvis rumtemperaturen falder, når udetemperaturen falder, er der valgt for lille en værdi for varmekurven. Hvis rumtemperaturen er tilpas, når udetemperaturen er lav (frostvejr), men rumtemperaturen er for lav, når det er varmere vejr, anbefales det at vælge en mindre værdi for varmekurven, og derefter foretage en Kurveforskydning (se afsnit 2.5.4) af varmekurven. 4.5 PAV max åbning (forpufninger) Maksimalbegrænsningen af åbningen af PAV under drift, er væsentlig for en problemfri drift. Den nødvendige maksimale åbningsgrad for PAV er afhængig af det valgte brændsel (type og fugtighed). Default indstillingerne for Max PAV ved de 4 forudindstillede trækvaliteter er baseret på henholdsvis hårdt træ (bøg og lignende) ved henholdsvis lille vandindhold og normalt vandindhold (15 25 % RH), og blødt træ (gran og lignende) ved lille vandindhold og normalt vandindhold (15 25 % RH). Symtomer på forpufning: Kedlen begynder at skyde Sekundær luft spjældet (SAV) åbner helt, og PAV lukker mere og mere i Flammen kommer og forsvinder i forbrændingskammeret når kedlen skyder, pustes flammen ud. Hvis det valgte brændsel er meget tørt og samtidigt kløvet ned i en lille diameter (<10 cm), vil det kunne opleves at kedlen ikke kan følge med forgasningen af brændet. Her hjælper det ikke at øge PAV maksimal indstillingen (ud fra ideen om at forsøge at skylle indfyringskammeret bedre igennem). Dette vil forværre forpufningstendensen. I stedet skal den maksimale hastighed for røgsugeren hæves (Installatør menu/kedelindstillinger/røgsugerindstillinger/max. hastighed). Ligeledes skal Røggastemp. delta (Installatør menu/kedelindstillinger/røggas indstillinger) hæves, og Sætpunkt ilt (Installatør menu/kedelindstillinger/iltsensor) sænkes. Den korrekte indstilling for det aktuelle brændsel må findes ved forsøg, men ved at følge ovenstående, vil man i de fleste tilfælde kunne finde indstillinger, som får driften til af foregå gnidningsløst.

28 Side Ekstra kedel Styringen kan håndtere frigivelse af en ekstern varmekilde, som forudsættes at opvarme primær lagertanken(e). Styringen har en 12 VDC udgang, som fx kan trække et relæ for gennemgang af 230 VAC til en oliebrænder, eller som en kontaktindgang til en elektronisk styring. Parameteren Ekstra kedel mode (Installatør menu) kan sættes til 2 forskellige kedeltyper: olie/gas kedel eller biomassekedel (fx træpillebrænder). Når en af disse typer er valgt, kan man med parameteren Ekstra kedel type angive hvorvidt den eksterne varmekilde er integreret i hovedkedlen eller er en ekstern kedel. Ved valget Integreret vil kedelpumpen aktiveres ved drift af den sekundære varmekilde. 12 VDC udgangen aktiveres, når temperaturen i den primære lagertank (T1 ved System 1 og 2, og T2 ved System 3) bliver lavere end Min. lagertanktemp. Opvarmningen af den primære lagertank fortsættes indtil (Max. lagertanktemp. minus Ekstra kedel stop hysterese) (Installatør menu/lagertank indstillinger) Når Ekstra kedel mode er valgt til Biomassekedel, tager systemet hensyn til den forlængede optændingstid en sådan kedel har i forhold til en olie eller gas kedel. Jo hurtigere lagertankstemperaturen falder, jo tidligere frigives den eksterne/sekundære varmekilde.

29 Side Opkobling af elforbindelser

30 Side 30 Forklaring af forkortelser: PAV Primary Air Valve Primær luft spjæld SAV Secondary Air Valve Sekundær luft spjæld SL - Iltsensor T1 - Tempertursensor 1 (top hovedtank) T2 - Tempertursensor 2 (midt hovedtank) T3 - Tempertursensor 3 (bund hovedtank) T4 - Tempertursensor 4 (top sekundærtank) STB Sicherheite Temperatur Begrenzer Overkogstermostat Forklaring af symboler: Udetempertaurføler Varmtvandstemperaturføler Kedeltemperaturføler Røggastemperaturføler Tempertursensor 1 (top hovedtank) Tempertursensor 2 (midt hovedtank) Tempertursensor 3 (bund hovedtank) Tempertursensor 4 (top sekundærtank) Blandekreds: symbol anvendes både ved temperaturfølerindgang, ved 3-vejs ventil udgang og ved direkte rumtermostatindgange. Der er angivet med hhv. 1 og 2, hvilken blandekreds der hører til. ecoster200 Udgang for start/stop af sekundær varmekilde, for opvarmning af tanksystem via denne. Pumpe. I kombination med de andre symboler angives den specifikke funktion. Fra hovedtank til sekundær tank (hovedtannk sort sekundær tank hvid) Fra sekundær tank til hovedtank. Røgsuger For opkobling og tilpasning af ekstraudstyr henvises til de individuelle manualer for disse.

31 Side 31 Notater:

32 Side Rev. 02/100316

Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2

Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2 Side 1 Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2 Side 2 Indholdsfortegnelse 1. GENERELLE INFORMATIONER... 3 2. SÅDAN FUNGERER LAGERTANKSYSTEMET... 4 3. SYSTEM 1: TO PARALLELKOBLEDE LAGERTANKE

Læs mere

ANLÆGSMANUAL. TPK HS20 17-08-2015 Side 1 TPK HS20

ANLÆGSMANUAL. TPK HS20 17-08-2015 Side 1 TPK HS20 Side 1 TPK HS20 Side 2 Indholdsfortegnelse 1. GENERELLE INFORMATIONER... 3 2. TRADITIONEL DIREKTE INSTALLATION... 4 3. DIREKTE INSTALLATION MED BLANDEKREDSE... 6 4. INSTALLATION AF INDIREKTE KREDS MED

Læs mere

ANLÆGSMANUAL. TPK HS Side 1

ANLÆGSMANUAL. TPK HS Side 1 Side 1 Side 2 Indholdsfortegnelse 1. GENERELLE INFORMATIONER... 3 2. TRADITIONEL DIREKTE INSTALLATION (VV BEHOLDER LANGT FRA KEDEL)... 4 3. TRADITIONEL DIREKTE INSTALLATION (VV BEHOLDER TÆT PÅ KEDEL)...

Læs mere

ANLÆGSMANUAL. TPK24 MK2 Scandpell Side 1. TPK24 MK2 Scandpell

ANLÆGSMANUAL. TPK24 MK2 Scandpell Side 1. TPK24 MK2 Scandpell Side 1 TPK24 MK2 Scandpell Side 2 Content 1. GENEREL INFORMATION... 3 2. TRADITIONELT DIREKTE INSTALLATION (VV BEHOLDER LANGT FRA KEDLEN)... 4 3. TRADITIONELT DIREKTE INSTALLATION (VV BEHOLDER TÆT PÅ KEDLEN)...

Læs mere

Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2

Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2 Side 1 Bonus 30 LC Solo Innova 30 LC MK2 Solo Innova 50 LC MK2 Side 2 Indholdsfortegnelse 1. LEVERING... 3 2. INSTALLATIONSMULIGHEDER... 4 2.1 STØRRELSE AF LAGERTANKE... 4 3. FORBEREDELSE AF KEDLEN...

Læs mere

STYRINGSMANUAL. TPK HS Side 1

STYRINGSMANUAL. TPK HS Side 1 STYRINGS Side 1 Side 2 Indholdsfortegnelse 1. MENUSTRUKTUR - OVERORDNET... 4 1.1 MENU-TRÆ... 6 2. BRUGERMENU... 7 2.1 INFORMATION... 8 2.2 KEDELINDSTILLINGER... 9 2.3 DRIFTS SETUP... 10 2.3.1 Fødesystem

Læs mere

RØGSUGER Top af skorsten TPK HS20/HS35

RØGSUGER Top af skorsten TPK HS20/HS35 Side 1 RØGSUGER Top af skorsten TPK HS20/HS35 Side 2 Indholdsfortegnelse 1. LEVERING... 3 2. INSTALLATION... 3 2.1 MONTERING AF RØGSUGER... 4 2.2 TRÆKSTABILISATOR... 4 3. OPKOBLING AF ELFORBINDELSER...

Læs mere

TM3006 Brugermanual. Tilstand: Drift o. O2 8.0% Opsætning. Tel: +45 96987711 Fax: +45 98661822

TM3006 Brugermanual. Tilstand: Drift o. O2 8.0% Opsætning. Tel: +45 96987711 Fax: +45 98661822 Techno-Matic A/S Granlidevej 22, Hornum DK-9600 Aars Denmark Tel: +45 96987711 Fax: +45 98661822 tm@techno-matic.dk www.techno-matic.dk Tilstand: Drift o >Temperatur 65.0 C O2 8.0% Opsætning START STOP

Læs mere

Nu er det ikke kun udetemperaturen der bestemmer behovet, men vindens afkølingseffekt (chill faktor) har også en stor betydning.

Nu er det ikke kun udetemperaturen der bestemmer behovet, men vindens afkølingseffekt (chill faktor) har også en stor betydning. Vejrkompensering - hvad er det? Vejrkompensering er en metode til at tilpasse fremløbstemperaturen til det aktuelle behov ud fra udetemperaturen. Ideen er at jo koldere det er udenfor, jo varmere behøver

Læs mere

Quickguide Alezio-IV Block V200 E/H Til forbrugeren

Quickguide Alezio-IV Block V200 E/H Til forbrugeren Quickguide Alezio-IV Block V200 E/H Til forbrugeren HS Tarm A/S Smedevej 2 DK-6880 Tarm Tlf. 97371511 Tillykke med din nye varmepumpe Din installatør har lavet en grundindstilling af din varmepumpe for

Læs mere

Bonus 30 STD MK2 Solo Innova 30 STD MK2 Solo Innova 50 STD MK2

Bonus 30 STD MK2 Solo Innova 30 STD MK2 Solo Innova 50 STD MK2 Side 1 Bonus 30 STD MK2 Solo Innova 30 STD MK2 Solo Innova 50 STD MK2 Side 2 Indholdsfortegnelse 1. LEVERING... 3 2. INSTALLATIONSMULIGHEDER... 4 2.1 STØRRELSE AF LAGERTANKE... 4 3. FORBEREDELSE AF KEDLEN...

Læs mere

JØMA STOKER. Styring PCT 241

JØMA STOKER. Styring PCT 241 JØMA STOKER Styring PCT 241 Side 1 Introduktion Tillykke med deres nye Jøma stoker anlæg. Anlægget er forsynet med en elektronisk styring med modulerende drift i fire trin. Hvilket vil sige, at styringen

Læs mere

KC Iltstyringstyring PCT 250 ILT

KC Iltstyringstyring PCT 250 ILT KC Iltstyringstyring PCT 250 ILT - Valgbar brændselstype ( Træpiller, Blandet, Flis ). - Programmerbar. - Fast undertemperatur funktion. - Opstartsprogram. - Driftprogram i 3 trin. - Pauseprogram - Forsyningsspænding

Læs mere

SUN-PRO.dk Solvarme fra Q-PRO

SUN-PRO.dk Solvarme fra Q-PRO SUN-PRO.dk Solvarme fra Q-PRO Solvarmestyring std Indholdsfortegnelse Copyright...2 Tekniske data...3 Elektriske tilslutninger...4 Valg af system...4 Opsætning af styringen...5 System 1 Én tank, uden ekstra

Læs mere

KC Stokerstyring. PCT 300 Uden ilt

KC Stokerstyring. PCT 300 Uden ilt KC Stokerstyring PCT 300 Uden ilt - Valgbar brændselstype ( Træpiller, Blandet, Flis ). - Opstartsprogram. - Driftsprogram i 3 trin. - Pauseprogram - Forsyningsspænding 3 400V / 50Hz eller 1 230V / 50Hz.

Læs mere

Betjeningsvejledning. Weishaupt Thermo Condens WTC 15-A udførelse K WTC 25-A udførelse K

Betjeningsvejledning. Weishaupt Thermo Condens WTC 15-A udførelse K WTC 25-A udførelse K Betjeningsvejledning Max Weishaupt A/S Erhvervsvej 10 DK-2600 Glostrup Telefon 43 27 63 00 Telefax 43 27 63 43 Tryk-nr. 83168009, dec. 2006 Max Weishaupt påtager sig intet ansvar for fejl og mangler i

Læs mere

ECL Comfort 110 230 V a.c. og 24 V a.c.

ECL Comfort 110 230 V a.c. og 24 V a.c. Datablad ECL Comfort 110 230 V a.c. og 24 V a.c. Beskrivelse og anvendelse Regulatoren er udviklet med henblik på let montering: et kabel, en tilslutning. ECL Comfort 110-regulatoren har et specialfremstillet

Læs mere

INSTALLATIONS- MANUAL - LAMBDA. TPK HS20 LAMBDA Side 1. Iltstyring TPK HS20

INSTALLATIONS- MANUAL - LAMBDA. TPK HS20 LAMBDA Side 1. Iltstyring TPK HS20 Side 1 Iltstyring TPK HS20 Side 2 Indholdsfortegnelse 1. LEVERING... 3 2. INSTALLATION... 4 2.1 MONTAGE AF ILTSONDE... 4 2.2 MONTAGE AF ILTMODULET (ECOLAMBDA)... 4 3. OPKOBLING AF ELFORBINDELSER... 5 4.

Læs mere

BRUGERMANUAL. Block Kondens MK Side 1. Block Kondens 18 MK6

BRUGERMANUAL. Block Kondens MK Side 1. Block Kondens 18 MK6 Side 1 Block Kondens 18 MK6 Side 2 Indholdsfortegnelse 1. OVERENSSTEMMELSEERKLÆRING... 4 2. OVERBLIK... 5 3. BETJENING AF BASALE FUNKTIONER... 6 3.1 INDSTILLING AF OPVARMNINGSFUNKTION... 7 3.2 AKTIVERING

Læs mere

BRUGERVEJLEDNING VER.

BRUGERVEJLEDNING VER. Dr.CropStore Styring af lager-temperatur BRUGERVEJLEDNING VER. 2.00 1 2 INDHOLDSFORTEGNELSE 1.0 Indledning....4 1.1 Knapindstilling, taster og display...................... 4 1.2 Indstilling, ændring af

Læs mere

STYRING FOR STOKERFYR

STYRING FOR STOKERFYR STYRING FOR STOKERFYR Måling og regulering af kedeltemperatur Måling og overvågning af røgtemperatur Eltænding og/eller pausefyring Mulighed for iltstyring Til Nordjysk Elektronik Ulvebakkevej 13 9330

Læs mere

Wavin AHC 8000 trådløs rumtermostat m/natsænkning

Wavin AHC 8000 trådløs rumtermostat m/natsænkning Wavin AHC 8000 trådløs rumtermostat m/natsænkning TIGRIS AHC 8000 trådløs programmerbar rumtermostat kan sammen med styreenheden AHC 8014 anvendes til styring af rum temperaturen i forbindelse med et gulvvarmeanlæg.

Læs mere

LILLE VEJLEDNING TIL BRUGERNE AF ELCO MINI

LILLE VEJLEDNING TIL BRUGERNE AF ELCO MINI LILLE VEJLEDNING TIL BRUGERNE AF ELCO MINI 1 Forord Denne lille vejledning til Elco-Mini-gasfyr er tænkt som en hjælp til at benytte de driftfunktioner, som dækker vore behov for manuelt at betjene de

Læs mere

INSTALLATIONS- OG BRUGERVEJLEDNING FLEX SUN DIGITAL SOLVARMESTYRING (26.01.11)

INSTALLATIONS- OG BRUGERVEJLEDNING FLEX SUN DIGITAL SOLVARMESTYRING (26.01.11) INSTALLATIONS- OG BRUGERVEJLEDNING FLEX SUN DIGITAL SOLVARMESTYRING (26.01.11) admin@batec.dk www.batec.dk Side 1 FLEX SUN Aktuel visning Driftsstatus Valg af temperaturvisning Manuel drift Programmering

Læs mere

INSTALLATIONSMANUAL - ASKEUDTAG

INSTALLATIONSMANUAL - ASKEUDTAG Side 1 TPK HS20/TPK HS35 Side 2 Indholdsfortegnelse 1. LEVERING... 3 2. INSTALLATION... 4 2.1 AFMONTERING AF NEDERSTE DØR OG NEDERSTE ASKELÅGE... 4 2.2 PÅSÆTNING AF DE 2 SORTE SIDEPANELER... 4 2.3 MONTAGE

Læs mere

Stokerstyring PCT 258 ILT

Stokerstyring PCT 258 ILT Stokerstyring PCT 258 ILT - Valgbar brændselstype ( Træpiller, Blandet, Flis ). - Ilt styring. - Opstartsprogram. - Driftprogram i 3 trin. - Pauseprogram - Forsyningsspænding 3 400V / 50Hz eller 1 230V

Læs mere

5-LCD FJERNBETJENING. Batterierne skal bortskaffes separat i de særlige batteriaffaldsbeholdere.

5-LCD FJERNBETJENING. Batterierne skal bortskaffes separat i de særlige batteriaffaldsbeholdere. GENERELLE SPECIFIKATIONER FOR LCD FJERNBETJENINGEN Fjernbetjeningen har en transmissionsfrekvens på 434,5 MHz. Den strømforsynes med 3 AAA batterier på følgende måde: fjern dækslet til batterirummet ved

Læs mere

TPK24 MK2 Scandpell Røgsuger bag pa kedlen

TPK24 MK2 Scandpell Røgsuger bag pa kedlen Side 1 TPK24 MK2 Scandpell Røgsuger bag pa kedlen Side 2 Content 1. LEVERING... 3 1.1 RØGSUGER MED STOR KAPACITET... 3 1.2 RØGSUGER STANDARD (KUBE)... 4 2. INSTALLATION... 6 2.1 INSTALLATION RØGSUGER MED

Læs mere

TIGRIS AHC 8000 trådløs programmerbar rumtermostat

TIGRIS AHC 8000 trådløs programmerbar rumtermostat Monteringsvejledning TIGRIS Cirkulation Nr. 6560878 / 010908 TIGRIS AHC 8000 trådløs programmerbar rumtermostat Installationsvejledning for TIGRIS AHC 8000 TRÅDLØS PROGRAMMERBAR RUMTERMOSTAT Klik dig ind

Læs mere

Brugsanvisning til varmesystem

Brugsanvisning til varmesystem Brugsanvisning til varmesystem Gulvvarmesystemet Brugervejledning: Gulvvarmesystemet sikrer optimale betingelser for et velfungerende og behageligt indeklima. Gulvvarmesystemet har en længere reaktionstid

Læs mere

MANUAL. for Sukup Europe silostyring. Kvalitet, styrke og effektivitet. Mimersvej 5, DK-8722 Hedensted, T: , E:

MANUAL. for Sukup Europe silostyring. Kvalitet, styrke og effektivitet. Mimersvej 5, DK-8722 Hedensted, T: , E: MANUAL for Sukup Europe silostyring Kvalitet, styrke og effektivitet Mimersvej 5, DK-8722 Hedensted, T: +45 7568 5311, E: info@sukup-eu.com // INDHOLDSFORTEGNELSE Oversigt styring side 1 Betjening af anlægget

Læs mere

Gulvvarme og træpillefyr.

Gulvvarme og træpillefyr. Gulvvarme og træpillefyr. Gulvvarme bliver mere og mere udbredt, da det er en meget behagelig og fordi det er meget anvendeligt sammen med lavtemperatur opvarmningsanlæg. Det smarte ligger egentlig i størrelsen

Læs mere

KONTROLPANEL ECO CLIMAX MULTI 22 DIGITAL. Display

KONTROLPANEL ECO CLIMAX MULTI 22 DIGITAL. Display Version A 4.01 Kopiering af denne manual er ikke tilladt KONTROLPANEL ECO CLIMAX MULTI 22 DIGITAL Snegl ON Kedel Temp Blæser Pumpe Display DRIFT Røg temp AUGER - COCLEA VENTOLA - FAN MAINT - MANTEN. POMPA

Læs mere

BETJENINGSVEJLEDNING KLIMASTAT TYPE 5610

BETJENINGSVEJLEDNING KLIMASTAT TYPE 5610 Side 1 af 7 Betjening af Klimastaten sker direkte på den trykfølsomme skærm. På skærmen findes 5 betjeningselementer. INFO, DRIFT, MANUEL, DATO, SETUP. Ved at klikke på et af ovenstående elementer åbnes

Læs mere

Sommerdrift på en NBE brænder.

Sommerdrift på en NBE brænder. Sommerdrift på en NBE brænder. Ved sommerdrift forstås en driftform hvor fyret ikke kører konstant, men blot kører når der er behov for varme til varmtvandsbeholderen (VVB en) eller til kortvarig opvarmning

Læs mere

ECL Comfort 210 / 310

ECL Comfort 210 / 310 MAKING MODERN LIVING POSSIBLE *087H9006* *VIKTY101* Du kan finde yderligere litteratur om ECL Comfort 210 og 310, moduler og tilbehør på http://www.danfoss.dk ECL Comfort 210 / 310 Brugervejledning Produced

Læs mere

MAKING MODERN LIVING POSSIBLE. ECL Comfort 210 / 310. Brugervejledning. Danfoss District Energy

MAKING MODERN LIVING POSSIBLE. ECL Comfort 210 / 310. Brugervejledning. Danfoss District Energy MAKING MODERN LIVING POSSIBLE ECL Comfort 210 / 310 Brugervejledning Danfoss District Energy Sikkerhedsadvarsel Montering, opstart og vedligeholdelse må kun udføres af kvalificerede og autoriserede teknikere.

Læs mere

1. Leveringsomfang... 3 2. Produktoverblik... 4. 2.1 Træ pille brænderens hoveddele...4 2.2 Vigtige dele - brænder...5. 3. Installation...

1. Leveringsomfang... 3 2. Produktoverblik... 4. 2.1 Træ pille brænderens hoveddele...4 2.2 Vigtige dele - brænder...5. 3. Installation... 1 Indhold 1. Leveringsomfang... 3 2. Produktoverblik... 4 2.1 Træ pille brænderens hoveddele...4 2.2 Vigtige dele - brænder...5 3. Installation... 6 3.1 Installation af brænderen...6 3.2 Installation med

Læs mere

Betjeningsvejledning. til. Vandkiosk. system

Betjeningsvejledning. til. Vandkiosk. system Betjeningsvejledning til Vandkiosk system Programnummer 731043 Tegningsnummer 201013 / 201019 www.tarp.dk 2012-02-20 1 Kundebetjening :... 4 AFLÆSNING AF DATA: 4 INDLÆSNING AF SPÆRRINGER: 4 FEJLMEDDELELSER:

Læs mere

- med Scandpell pillebrænder. Drifts- og vedligeholdelsesmanual

- med Scandpell pillebrænder. Drifts- og vedligeholdelsesmanual - med Scandpell pillebrænder Drifts- og vedligeholdelsesmanual 1 Kære kunde. Tillykke med dit nye BAXI produkt. Nærværende manual er én manual ud af et sæt på to. Sættet består af: Installationsmanual

Læs mere

Montørvejledning for DTC2100 Temperaturtyring - Version 1. Generel beskrivelse

Montørvejledning for DTC2100 Temperaturtyring - Version 1. Generel beskrivelse 1 2 3 R DTC2100 Danotek Generel beskrivelse DTC2100 er udviklet til væskebaseret solfangersystemer, men kan også benyttes til anden temperatur styring med op til tre temperatur målinger og en relæudgang.

Læs mere

Lavtemperaturfjernvarme. Christian Kepser, 19. marts 2013 Energi teknolog studerende. SFO Højkær

Lavtemperaturfjernvarme. Christian Kepser, 19. marts 2013 Energi teknolog studerende. SFO Højkær SFO Højkær Lavtemperaturfjernvarme Christian Kepser, 19. marts 213 Energi teknolog studerende Indledning Lavtemperatur fjernvarme er som nævnet antyder, fjernvarme med en lavere fremløbstemperatur. Fremløbstemperaturen

Læs mere

Siemens RVA 53.140 varmestyring til CTC 960

Siemens RVA 53.140 varmestyring til CTC 960 2005.06 Siemens RVA 53.140 varmestyring til CTC 960 Betjeningsvejledning Kvikmanual Monteringsvejledning Installatørprogrammering Kontrol af følere SIEMENS RVA 53.140 KEDEL-VARMKREDS- BRUGSVANDSSTYRING

Læs mere

INSTALLATIONSVEJLEDNING. Rumtermostat EKRTWA

INSTALLATIONSVEJLEDNING. Rumtermostat EKRTWA INSTALLATIONSVEJLEDNING 1 1 2 2 60 mm/2.36 inch 87 mm/3.43 inch ±1.5 m ±60 inch >0.2 m >8 inch 3 34 mm/1.34 inch 125 mm/4.92 inch 3 Læs denne manual grundigt igennem, før du starter enheden op. Gem den.

Læs mere

Indhold 1. Leveringsomfang... 3 2. Produktoverblik... 4 3. Installation... 5 3.1 Installationsdiagrammer...5 3.1.1 Installation med Scandpell,

Indhold 1. Leveringsomfang... 3 2. Produktoverblik... 4 3. Installation... 5 3.1 Installationsdiagrammer...5 3.1.1 Installation med Scandpell, 1 Indhold 1. Leveringsomfang... 3 2. Produktoverblik... 4 3. Installation... 5 3.1 Installationsdiagrammer...5 3.1.1 Installation med Scandpell, lagertank O og ekstern VV beholder...5 3.2 Underlag...6

Læs mere

Servicemanual for TM 3006

Servicemanual for TM 3006 Servicemanual for TM 3006 3/2005 Per Øster R/A 1 Denne manual er skrevet til det autoriserede servicefirmas teknikere. I manualen er beskrevet indstillinger, der har at gøre med grundlæggende funktioner

Læs mere

Opstartsguide. Betjeningsenhed RC35. Til brugeren. Bedes læst omhyggeligt før ibrugtagning /2008 DA

Opstartsguide. Betjeningsenhed RC35. Til brugeren. Bedes læst omhyggeligt før ibrugtagning /2008 DA Opstartsguide Betjeningsenhed RC35 Til brugeren Bedes læst omhyggeligt før ibrugtagning 6 720 617 924 07/2008 DA Indholdsfortegnelse Indholdsfortegnelse 1 Før start af kedel... 3 2 Start af kedel.... 4

Læs mere

Sammenkobling af gulvvarmestyring og Danfoss ECL Comfort 110 eller 210/310 regulator.

Sammenkobling af gulvvarmestyring og Danfoss ECL Comfort 110 eller 210/310 regulator. Sammenkobling af gulvvarmestyring og Danfoss ECL Comfort 110 eller 210/310 regulator. Indholdsfortegnelse Funktionsbeskrivelse... 2 El-tilslutning... 2 ECL 110... 2 ECL 210 og 310... 3 ECL indstillinger...

Læs mere

Svane Electronic Timer universal med 8 funktioner 1

Svane Electronic Timer universal med 8 funktioner 1 Svane Electronic Timer universal med 8 funktioner 1 Digital timer print modul 12V 2000.2231 Multi funktions timer med 8 funktioner, anvendelig i mange installationer, forsyning 12VDC drift. Printet har

Læs mere

BRUGERVEJLEDNING. Rumenhed REG 73. T Installatør

BRUGERVEJLEDNING. Rumenhed REG 73. T Installatør BRUGERVEJLEDNING Rumenhed REG 73 T30.33156.0 Installatør 1 - Betjening 1 Manuel omskiftning mellem komfortog økonomitemperatur Indstilling af ønsket rumtemperatur 3 Visning af driftinformationer (Infoknap)

Læs mere

Montørvejledning for DTC2102 Temperaturtyring - Version 1. Generel beskrivelse

Montørvejledning for DTC2102 Temperaturtyring - Version 1. Generel beskrivelse 1 2 3 R E DTC2102 Danotek Generel beskrivelse DTC2102 er udviklet til væskebaseret solfangersystemer, men kan også benyttes til anden temperatur styring med op til tre temperatur målinger og to relæudgange.

Læs mere

FSystem beskrivelse PAR 200 CLOCK

FSystem beskrivelse PAR 200 CLOCK FSystem beskrivelse PAR 200 CLOCK Driftvejledningsnr: PAR-200-SYS-DK-041223 Beskrivelse Billede PAR-200-SYS er den overordnede og komplette beskrivelse af Ølands nye tidsstyring inden for analoge regulatorer.

Læs mere

Quickguide Alezio AWHP 220 E/T til installatøren

Quickguide Alezio AWHP 220 E/T til installatøren Quickguide Alezio AWHP 220 E/T til installatøren Følgende komponenter kan være medleveret. Ude-modul Alezio 6-11-16 kw Inde-modul med indbygget el-patron og 220 liter varmtsvandsbeholder Udeføler Buffertank

Læs mere

MANUAL FANTRONIC 20AMP. TRIAC SLAVEENHED FOR VENTILATION VER:FAN 1.1 SKIOLD GØR EN FORSKEL!

MANUAL FANTRONIC 20AMP. TRIAC SLAVEENHED FOR VENTILATION VER:FAN 1.1 SKIOLD GØR EN FORSKEL! MANUAL SKIOLD GØR EN FORSKEL! FANTRONIC 20AMP. TRIAC SLAVEENHED FOR VENTILATION VER:FAN 1.1 981 002 317 Ver. 01 11-03-2013 Indhold 1. INTRODUKTION... 4 2. BESKRIVELSE FANTRONIC... 5 2.1 SÅDAN FUNGERER

Læs mere

Agenda. Teknisk gennemgang v/ Thomas Tørnberg. Centralvarme Varmt brugsvand Afkøling Sommerluk Adfærd

Agenda. Teknisk gennemgang v/ Thomas Tørnberg. Centralvarme Varmt brugsvand Afkøling Sommerluk Adfærd 1 Agenda Teknisk gennemgang v/ Thomas Tørnberg Centralvarme Varmt brugsvand Afkøling Sommerluk Adfærd Kend dit fjernvarmeanlæg Der er 4 vigtige ting, som du bør være opmærksom på, når du har med fjernvarme

Læs mere

Manual. VentCom Apollo-Multi Ver. 018.01.DK. Manual nr. 982002600 Ver 3.00 01.12.2006. SKIOLD A/S Kjeldgaardsvej 3 DK-9300 Sæby Danmark

Manual. VentCom Apollo-Multi Ver. 018.01.DK. Manual nr. 982002600 Ver 3.00 01.12.2006. SKIOLD A/S Kjeldgaardsvej 3 DK-9300 Sæby Danmark Manual VentCom Apollo-Multi Ver. 018.01.DK Manual nr. 982002600 Ver 3.00 01.12.2006 SKIOLD A/S Danmark Vejledning i brug af VentCom sammen med Apollo Multi. VentCom er et program, som kan præsentere aktuelle

Læs mere

X88S. SMS fjernstyring til sommerhuse

X88S. SMS fjernstyring til sommerhuse X88S SMS fjernstyring til sommerhuse X88s er en GSM/SMS baseret fjernstyring med: 6 indgange 8 relæudgange 2 temperaturfølere Billig i drift, intet abonnement. Kan køre på taletidskort. Nem og hurtig montering.

Læs mere

TM3006 Brugermanual. Tilstand: Drift o. O2 8.0% Opsætning INDHOLDSFORTEGNELSE. Techno-Matic A/S Granlidevej 22, Hornum DK-9600 Aars Denmark

TM3006 Brugermanual. Tilstand: Drift o. O2 8.0% Opsætning INDHOLDSFORTEGNELSE. Techno-Matic A/S Granlidevej 22, Hornum DK-9600 Aars Denmark Techno-Matic A/S Granlidevej 22, Hornum DK-9600 Aars Denmark Tel: +45 96987711 Fax: +45 98661822 tm@techno-matic.dk www.techno-matic.dk Tilstand: Drift o >Temperatur 65.0 C O2 8.0% Opsætning START STOP

Læs mere

MANUAL FOR DTC 9002 Styringen :

MANUAL FOR DTC 9002 Styringen : MANUAL FOR DTC 9002 Styringen : Styringen er udviklet til styring af træpille brænder med automatisk eltænding. For at kunne regulere ydelsen på fyret til det aktuelle behov måler styringen temperaturen

Læs mere

Kvikguide. flexocompact og flexotherm exclusive

Kvikguide. flexocompact og flexotherm exclusive Kvikguide flexocompact og flexotherm exclusive Vaillant varmepumper i enkelt og tidløst design Rørforbindelser flexotherm Brine fra varmepumpe Brine til varmepumpe Fremløb varmtvandsbeholder Sikkerhedsventil

Læs mere

Tænd for styringen og sørg for at den er i tilstand STOP, hvis ikke, så hold PIL NED inde i 10 sekunder til brænderen stopper.

Tænd for styringen og sørg for at den er i tilstand STOP, hvis ikke, så hold PIL NED inde i 10 sekunder til brænderen stopper. Opstart og justering af forbrænding på NBE pillebrænder Woody v4.99. Grundforudsætninger: Der er monteret en velfungerende trækstabilisator i skorstenen eller på røgrøret Trækstabilisatoren er indstillet

Læs mere

Betjeningsvejledning for digital CPU-styring TX Control

Betjeningsvejledning for digital CPU-styring TX Control Betjeningsvejledning for digital CPU-styring TX Control Turbovex A/S Industrivej 9600 Aars Tlf. 96 98 6 Fax 98 6 E-mail: info@turbovex.dk TX Control SETPUNKT TEMP. OP SETPUNKT TEMP. NED BLÆSERTRIN OP BLÆSERTRIN

Læs mere

Dr.CropStore /med strømforsyning DC2

Dr.CropStore /med strømforsyning DC2 Dr.CropStore /med strømforsyning DC2 Styring af lager-temperatur 1.0 El-tilslutning INSTALLATION VER. 2.00 Kabler Temperaturføler- og styrespændingssignaler fremføres separat i skærmet kabel og mindst

Læs mere

Building Technologies

Building Technologies s Building Technologies anual Varmestyring for CTC 950 Kondens V2.0 Bedienelemente B Vælger for varmtvandsproduktion AVælger for drifttype på varmekredsen Auto 0 4 8 12 16 20 24 ESC OK Forlad aktuelle

Læs mere

Betjeningsvejledning for træpilleovns brugere og service. max1 plus

Betjeningsvejledning for træpilleovns brugere og service. max1 plus Betjeningsvejledning for træpilleovns brugere og service max1 plus Dans k Februar 2012 Version: mst 120119 max1plus end customer (max1) Item number: as of SW 1.01 All rights reserved, subject to changes.

Læs mere

Roth Touchline Vejledning til opsætning af system ved køling

Roth Touchline Vejledning til opsætning af system ved køling Roth Touchline Vejledning til opsætning af system ved køling Living full of energy /7 Indholdsfortegnelse Roth Touchline reguleringssystem kan indstilles på flere forskellige måder når det skal fungere

Læs mere

NV Comfort Brugervejledning

NV Comfort Brugervejledning NV Comfort Brugervejledning Tillykke med Deres nye NV Comfort indeklimaløsning, der året rundt er med til at sikre et sundt og komfortabelt indeklima med en ekstrem lav CO-udledning. Med NV Comfort Standard

Læs mere

Bruger manual AGAM kontrolboks

Bruger manual AGAM kontrolboks Bruger manual AGAM kontrolboks Kontrol boks set- up Front tavle (dør) 1. LED : Indikerer hvilke funktioner der er tilsluttet. (Lys tændt = funktion tændt ; lys slukket = funktion slukket). #1- Hovedpumpe

Læs mere

Tabel over brugsstedsindstillinger

Tabel over brugsstedsindstillinger /7 [6.8.] =... ID43/46 Relevante indendørsenheder *GSQHS8AA9W ThermaliaC* Bemærkninger - 4P3938-D -. /7 Brugerindstillinger Forudindstillede værdier Rumtemperatur 7.4.. Komfort (opvarmning) R/W [3-7]~[3-6],

Læs mere

Brugervejledning DB stokerfyr

Brugervejledning DB stokerfyr Brugervejledning DB stokerfyr Stokergården Rævehøjvej 1 6933 Kibæk Tlf. 97192017 / 40765626 MONTERING AF STOKER PÅ KEDEL Der er to ledninger som skal forbindes mellem kedel og stoker, pt 1000 vand og overkog.

Læs mere

Model BABY. WWW.VVS-Eksperten.dk

Model BABY. WWW.VVS-Eksperten.dk PANNEX PILLE BRÆNDEOVN Model BABY WWW.VVS-Eksperten.dk Indholdsfortegnelse: Sikkerheds normer... 2 Tekniske detaljer for model Baby Pille brændeovn... 2 Træpille type... 3 Opstart med pille brændeovn...

Læs mere

Opvarmning med naturlig varme

Opvarmning med naturlig varme varmepumper Opvarmning med naturlig varme www.hstarm.dk Kom i kredsløb med jorden Jorden omkring din bolig gemmer på masser af energi. Faktisk skal du ikke længere end 1 til 1,5 meter ned under overfladen

Læs mere

Dr.Heron med tilslutningsprint DCT

Dr.Heron med tilslutningsprint DCT Dr.Heron med tilslutningsprint DCT TEMPERATUR - STYRING 1.0 El-tilslutning Kabler INSTALLATION Anbefalet kabeltype: YSY-JZ. Temperaturføler- og styrespændingssignaler fremføres i separat, skærmet kabel

Læs mere

Montørvejledning for DTC2200 Energistyring - Version 4

Montørvejledning for DTC2200 Energistyring - Version 4 T1 E T5 V T4 N T3 T2 P Generel beskrivelse DTC2200 er udviklet til væskebaseret solfangersystemer. Styringen kan benyttes til anlæg med brugsvand og rumvarme i følgende kombinationer: 1: Brugsvands styring

Læs mere

1. Stokerfyr som åbent eller lukket anlæg uden anlægsshunt

1. Stokerfyr som åbent eller lukket anlæg uden anlægsshunt 1. Stokerfyr som åbent eller lukket anlæg uden anlægsshunt Vlås M T Kedel med dispensation fra AT 42 afsnit 2 Tf 2 V5 V2 V Brandsikring V3 1 q:\acadtegn\ars\ars\01 rev 1.dwg Stokerfyret kedel Anlægget

Læs mere

Træpillefyr M. www.biovarme.dk

Træpillefyr M. www.biovarme.dk Træpillefyr M www.biovarme.dk Træpillefyr M Gør en forskel for miljøet Nemt at installere og betjene Med en virkningsgrad helt i top er Automatisk optænding og modulerende drift DENVIRO træpillefyr udviklet

Læs mere

ECL Comfort 210 / 296 / 310

ECL Comfort 210 / 296 / 310 Brugervejledning ECL Comfort 210 / 296 / 310 Dansk udgave www.danfoss.com Sikkerhedsadvarsel Montering, opstart og vedligeholdelse må kun udføres af kvalificerede og autoriserede teknikere. 2 Danfoss 2016.02

Læs mere

Varmeflytning for Holly/RC120

Varmeflytning for Holly/RC120 Varmeflytning for Varme.ytning for modellen 2 Varmeflytning indgang VENSTRE Varmeflytning indgang HØJRE (udstødningsgasser) Afbryder som aktiverer varmeflytningsindgangen til HØJRE Afbryder som aktiverer

Læs mere

Flex Sun. Brugervejledning. Tac-Ware

Flex Sun. Brugervejledning. Tac-Ware Flex Sun Brugervejledning TacWare VVS Grossisten A/S Industrivej 61 7080 Børkop Telefon 72 41 41 41 Fax 72 41 41 99 Aktuel visning Driftstatus Valg af temperatur visning manuel drift Programmering Dette

Læs mere

CTC 960 Villaunit Teknisk instruktion Installation - drift og vedligeholdelse

CTC 960 Villaunit Teknisk instruktion Installation - drift og vedligeholdelse Part no 580325007/2 Dk. Jan -06 Fra serie nr. 7065-0211-41 CTC 960 Villaunit Teknisk instruktion Installation - drift og vedligeholdelse 161 103 07 06-01 161 503 03 06-01 01. Generelt...5 02. Teknisk beskrivelse

Læs mere

KC Stokerstyring PCT 241

KC Stokerstyring PCT 241 KC Stokerstyring PCT 241 - Valgbar brændselstype ( Træpiller, Blandet, Flis ). - Opstartsprogram. - Driftsprogram i 3 trin. - Pauseprogram - Forsyningsspænding 3 400V / 50Hz eller 1 230V / 50Hz. - Tyristor-styret

Læs mere

Compact C+ kedel med P23 Brænder

Compact C+ kedel med P23 Brænder Quick guide Compact C+ kedel med P23 Brænder 1.3 Opstilling Start med at pakke det hele ud og opstille kedel og pilletank på et jævnt og stabilt underlag. Tilslut skorsten til kedlen. Tilslut fremløb og

Læs mere

INSTALLATIONSVEJLEDNING. Rumtermostat EKRTW

INSTALLATIONSVEJLEDNING. Rumtermostat EKRTW INSTALLATIONSVEJLEDNING 1 1 2 2 60 87 ±1.5 m >0.2 m 3 34 125 3 Læs denne manual grundigt igennem, før du starter enheden op. Gem den. en skal opbevares til fremtidig brug. Forkert installation eller montering

Læs mere

Vejledning om ventilation og varmeforsyning

Vejledning om ventilation og varmeforsyning Vejledning om ventilation og varmeforsyning AlmenBolig+ boligerne er opført som lavenergiboliger, og har derfor et mindre varmebehov end traditionelle bygninger. Boligerne har et integreret anlæg, der

Læs mere

MAKING MODERN LIVING POSSIBLE. FloorLine Klimapaneler Brugervejledning

MAKING MODERN LIVING POSSIBLE. FloorLine Klimapaneler Brugervejledning DK FloorLine Klimapaneler Brugervejledning Indhold Indledning.......................................... side 3 Konstruktion........................................ side 4 Anvendelse af Convec CHR rumtermostat............

Læs mere

Fjernbetjening Flex Teknisk manual

Fjernbetjening Flex Teknisk manual Fjernbetjening Flex Teknisk manual VEKA INT. Indblæsnings aggregat 1 Beskrivelse Flex fjernbetjening kan bruges til at styre ventilationsanlæg med V1 og V2 printkort. Tekniske data Knapper på display Knap

Læs mere

System JA 1000 Stand-alone styring for befugter eller affugter for relativ fugtighed og eller dugpunkt.

System JA 1000 Stand-alone styring for befugter eller affugter for relativ fugtighed og eller dugpunkt. KHV Maj 2012 Version 3.1 Brugsanvisning System JA 1000 Stand-alone styring for befugter eller affugter for relativ fugtighed og eller dugpunkt. Anderberg Fugtstyring A/S - Gl. Holbækvej 6-8 - 4200 Slagelse

Læs mere

Kondenserende kedel ZSB 3-16 A 23 ZSB 7-22 A 23. 6 720 610 791 Dk (02.05) OSW 6 720 610 790-00.1O

Kondenserende kedel ZSB 3-16 A 23 ZSB 7-22 A 23. 6 720 610 791 Dk (02.05) OSW 6 720 610 790-00.1O Kondenserende kedel 6 720 610 790-00.1O ZSB 3-16 A 23 ZSB 7-22 A 23 OSW Indholdsfortegnelse Indholdsfortegnelse Sikkerhedsråd 3 Symbolforklaring 4 1 Betjeningsoversigt 5 2 Idriftsætning 6 2.1 Inden idriftsætning

Læs mere

Betjeningsvejledning Weishaupt Thermo Condens WTC 15-A WTC 25-A WTC 32-A

Betjeningsvejledning Weishaupt Thermo Condens WTC 15-A WTC 25-A WTC 32-A Max Weishaupt A/S Erhvervsvej 10 DK-2600 Glostrup Telefon 43 27 63 00 Telefax 43 27 63 43 Tryk-nr. 83053109, dec. 2006 Max Weishaupt påtager sig intet ansvar for fejl og mangler i vejledningen. Eftertryk

Læs mere

Quickguide Alezio-II solo m/el-backup

Quickguide Alezio-II solo m/el-backup Quickguide Alezio-II solo m/el-backup HS Tarm A/S Smedevej DK-6880 Tarm tlf. 97371511 Quickguide Alezio-II AWHP Solo med el-backup Til indedel uden indbygget varmtvandsbeholder Følgende komponenter kan

Læs mere

Indendørs enhed for luft-/vandvarmepumpen

Indendørs enhed for luft-/vandvarmepumpen 6 720 614 054-00.1D Indendørs enhed for luft-/vandvarmepumpen CC 160 da Betjeningsvejledning 6 720 614 434 DK (2007/06) OSW 2 Indholdsfortegnelse DK Indholdsfortegnelse 1 Sikkerhedsråd og symbolforklaring

Læs mere

Svane Electronic Timer universal med 8 funktioner 1

Svane Electronic Timer universal med 8 funktioner 1 Svane Electronic Timer universal med 8 funktioner 1 Digital timer print modul 12V 2000.2231 Multi funktions timer med 8 funktioner, anvendelig i mange installationer, forsyning 12VDC drift. Printet har

Læs mere

Motorline JAG (indbygget limit switch) Dansk brugermanual

Motorline JAG (indbygget limit switch) Dansk brugermanual Motorline JAG (indbygget limit switch) Dansk brugermanual Til brug for Motorline MC2 kontrolpanel i kombination med Motorline JAG eller Motorline LINCE 230Vac lågeautomatik. Motorline LINCE (kører på tid)

Læs mere

Installationsvejledning for TIGRIS Maxishunt 6560898 / 010409 1/12

Installationsvejledning for TIGRIS Maxishunt 6560898 / 010409 1/12 6560898 / 010409 1/12 Installationsvejledning for TIGRIS Maxishunt Klik dig ind på www.wavin.dk eller kontakt Wavins vvs-afdeling på tlf. 8696 2000, hvis du har brug for råd og vejledning omkring gulvvarmesystemer.

Læs mere

B R U G E R M A N U A L. Kondenserende oliekedel AVS 37.390. Anvendelse af kedlen uden indeklimamodul. Ref.: : BA - 1383 - U - 0 - DA - 07 / 01

B R U G E R M A N U A L. Kondenserende oliekedel AVS 37.390. Anvendelse af kedlen uden indeklimamodul. Ref.: : BA - 1383 - U - 0 - DA - 07 / 01 B R U G E R M A N U A L Kondenserende oliekedel AVS 37.390 Anvendelse af kedlen uden indeklimamodul Ref.: : BA - 1383 - U - 0 - DA - 07 / 01 1 2 1 BETJENING 1.1 Betjeningselementer Lampe for overkog Overkogssikring

Læs mere

Tabel over brugsstedsindstillinger

Tabel over brugsstedsindstillinger /7 [6.8.] =... ID66F / ID66F3 Relevante indendørsenheder *GSQHS8AA9W ThermaliaC* Bemærkninger /7 Brugerindstillinger Forudindst. værdier Rumtemperatur 7.4.. Komfort (opvarmning) R/W [3-7]~[3-6], trin:

Læs mere

Albatros2 Grafisk brugerflade UI400 Kort brugervejledning

Albatros2 Grafisk brugerflade UI400 Kort brugervejledning Albatros2 Grafisk brugerflade UI400 Kort brugervejledning CE1C2348da 2014-04-23 Building Technologies Velkommen! Velkommen! Brug betjeningsknappen (tryk-og-drej) til betjening af både rumapparat QAA74

Læs mere

Drifts- og vedligeholdelsesvejledning. gulvvarmeanlæg. Living full of energy

Drifts- og vedligeholdelsesvejledning. gulvvarmeanlæg. Living full of energy Drifts- og vedligeholdelsesvejledning til Roth gulvvarmeanlæg Living full of energy Sådan virker dit anlæg Tillykke med dit nye gulvvarmesystem fra Roth Nordic. Denne vejledning sikrer dig en optimal funktion

Læs mere

Ventilationsaggregater. Topvex FR, SR, TR

Ventilationsaggregater. Topvex FR, SR, TR Topvex FR, SR, TR 206951-DK 22-08-2011V.A004 (C. 3.0-1-06) Indhold 1... 1 1.1 Funktionsindstillinger... 1 1.2 Indstilling af ugeprogram... 5 1.3 Alarmkonfiguration... 6 1.4 Noter og underskrift... 9 1

Læs mere

Tabel over brugsstedsindstillinger

Tabel over brugsstedsindstillinger 1/8 Relevante indendørsenheder *GSQH1S18AA9W ThermaliaC12* Bemærkninger - *GSQH1S18AA9W / ThermaliaC12* 4P359382-1C - 214.3 2/8 3/8 Brugerindstillinger Forudindstillede værdier Rumtemperatur 7.4.1.1 Komfort