Ventil- / alarmdriver. Nr. 9203V105-DK Produktversion:

Størrelse: px
Starte visningen fra side:

Download "Ventil- / alarmdriver. Nr. 9203V105-DK Produktversion:"

Transkript

1 9203 Ventil- / alarmdriver Nr. 9203V105-DK Produktversion:

2 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv barske miljøer med elektrisk støj, vibrationer og temperaturudsving, og alle produkter opfylder de strengeste internationale standarder. Vores motto»signals the Best«er indbegrebet af denne filosofi og din garanti for kvalitet. PR electronics A/S offers a wide range of analog and digital signal conditioning devices for industrial automation. The product range includes Isolators, Displays, Ex Interfaces, Temperature Transmitters, and Universal Devices. You can trust our products in the most extreme environments with electrical noise, vibrations and temperature fluctuations, and all products comply with the most exacting international standards.»signals the Best«is the epitome of our philosophy and your guarantee for quality. PR electronics A/S offre une large gamme de produits pour le traite ment des signaux analogiques et numériques dans tous les domaines industriels. La gamme de produits s étend des transmetteurs de température aux afficheurs, des isolateurs aux interfaces SI, jusqu aux modules universels. Vous pouvez compter sur nos produits même dans les conditions d utilisation sévères, p.ex. bruit électrique, vibrations et fluctuations de température. Tous nos produits sont conformes aux normes internationales les plus strictes. Notre devise»signals the BEST«c est notre ligne de conduite - et pour vous l assurance de la meilleure qualité. PR electronics A/S verfügt über ein breites Produktprogramm an analogen und digitalen Signalverarbeitungsgeräte für die industrielle Automatisierung. Dieses Programm umfasst Displays, Temperaturtransmitter, Ex- und galvanische Signaltrenner, und Universalgeräte. Sie können unsere Geräte auch unter extremen Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen und Temperaturschwingungen vertrauen, und alle Produkte von PR electronics werden in Überein stimmung mit den strengsten internationalen Normen produziert.»signals the Best«ist Ihre Garantie für Qualität! 1508

3 Ventil- / alarmdriver 9203 Indhold Advarsel... 2 Signaturforklaring... 2 Sikkerhedsregler... 2 Afmontering af system Avancerede features... 5 Anvendelse... 5 Teknisk karakteristik... 6 Applikationer Axxx... 7 Applikationer Bxxx... 8 PR 4501 Display- / programmeringsfront... 9 Påsætning / aftagning af PR4501/ Bestillingsskema : Hardware- / softwarefejl Tilslutninger Blokdiagram Visning af signalfejl uden displayfront Programmering / betjening af trykknapper Rutediagram Rutediagram, Avancerede indstillinger (ADV.SET) Rullende hjælpetekster i displaylinie Appendix IECEx Installation Drawing ATEX Installationstegning FM Installation Drawing INMETRO Installation Drawing Safety Manual Product Version

4 Advarsel Følgende operationer bør kun udføres på modulet i spændingsløs tilstand og under ESD-sikre forhold: Installation, ledningsmontage og -demontage. Fejlfinding på modulet. Reparation af modulet og udskiftning af sikringer må kun foretages af PR electronics A/S. ADVARSEL Modulets frontplade må ikke åbnes, da dette vil medføre skade på stikforbindelsen til display- / programmeringsfronten PR Modulet indeholder ingen DIP-switche eller jumpere. Signaturforklaring Trekant med udråbstegn: Læs manualen før installation og idriftsættelse af modulet for at undgå hændelser, der kan føre til skade på personer eller materiel. CE-mærket er det synlige tegn på modulets overensstemmelse med EU - direktivernes krav. Dobbelt isolation er symbolet for, at modulet overholder ekstra krav til isolation. Ex - Modulet er godkendt efter ATEX-direktivet til brug i forbindelse med installationer i eksplosionsfarlige områder. Se installation drawings i appendiks. Sikkerhedsregler Definitioner Farlige spændinger er defineret som områderne: Volt DC og Volt AC. Teknikere er kvalificerede personer, som er uddannet eller oplært til at kunne udføre installation, betjening eller evt. fejlfinding både teknisk og sikkerhedsmæssigt forsvarligt. Operatører er personer, som under normal drift med produktet skal indstille og betjene produktets trykknapper eller potentiometre, og som er gjort bekendt med indholdet af denne manual Product Version

5 Modtagelse og udpakning Udpak modulet uden at beskadige det. Kontrollér ved modtagelsen, at modultypen svarer til den bestilte. Indpakningen bør følge modulet, indtil dette er monteret på blivende plads. Miljøforhold Undgå direkte sollys, kraftigt støv eller varme, mekaniske rystelser og stød, og udsæt ikke modulet for regn eller kraftig fugt. Om nødvendigt skal opvarmning, ud over de opgivne grænser for omgivelsestemperatur, forhindres ved hjælp af ventilation. Modulet skal installeres i forureningsgrad 2 eller bedre. Modulet er designet til at være sikkert mindst op til en højde af 2000 m. Installation Modulet må kun tilsluttes af teknikere, som er bekendte med de tekniske udtryk, advarsler og instruktioner i manualen, og som vil følge disse. Hvis der er tvivl om modulets rette håndtering, skal der rettes henvendelse til den lokale forhandler eller alternativt direkte til: PR electronics A/S Ved tilslutning af flerkorede ledninger med farlig spænding skal ledningsenderne forsynes med ledningstyller. Beskrivelse af indgang / udgang og forsyningsforbindelser findes på blokdiagrammet og sideskiltet. Modulet er forsynet med skrueterminaler og skal forsynes fra en dobbeltisoleret / forstærket isoleret spændingsforsyning. En afbryder placeres let tilgængeligt og tæt ved modulet. Afbryderen skal mærkes således, at der ikke er tvivl om, at den afbryder spændingen til modulet. Ved installation på Power Rail 9400 bliver forsyningsspændingen leveret af Power Control Unit type Produktionsår fremgår af de to første cifre i serienummeret. Kalibrering og justering Under kalibrering og justering skal måling og tilslutning af eksterne spændinger udføres i henhold til denne manual, og teknikeren skal benytte sikkerhedsmæssigt korrekte værktøjer og instrumenter Product Version

6 Betjening under normal drift Operatører må kun indstille eller betjene modulerne, når disse er fast installeret på forsvarlig måde i tavler el. lignende, så betjeningen ikke medfører fare for liv eller materiel. Dvs., at der ikke er berøringsfare, og at modulet er placeret, så det er let at betjene. Rengøring Modulet må, i spændingsløs tilstand, rengøres med en klud let fugtet med destilleret vand. Ansvar I det omfang instruktionerne i denne manual ikke er nøje overholdt, vil kunden ikke kunne rette noget krav, som ellers måtte eksistere i henhold til den indgåede salgsaftale, mod PR electronics A/S. Afmontering af system 9000 Billede 1: Modulet frigøres fra power railen ved at løfte i den nederste lås Product Version

7 Ventil- / alarmdriver 9203 Universel driver for ventiler, akustiske alarmer og lysdioder Udvidet autodiagnosticering 1 eller 2 kanaler Kan forsynes separat eller installeres på power rail, PR type 9400 SIL 2-certificeret via Full Assessment Avancerede features 9203Bxx har 3 indbyggede Ex-barrierer. To hardwareversioner giver mulighed for valg af Low (35 ma) eller High (60 ma) strømudgang. Opsætning og monitorering via aftagelig displayfront (PR 4501). Valg af direkte eller indirekte funktion for hver kanal via PR 4501 og mulighed for at reducere udgangsstrømmen til Ex-området efter behov. Mulighed for monitorering af udgangsstrømmen til Ex-område via PR Mulighed for redundant forsyning via power rail og/eller separat forsyning. Anvendelse 9203Bxxx kan monteres i sikkert område samt i zone 2 / division 2 og sende signaler til zone 0, 1, 2, 20, 21, 22 og M1 / Class I/II/III, Div. 1, Gr. A-G. Ex-driver til styring af ON / OFF ventiler, akustiske alarmer og lysdioder placeret i eksplosionsfarligt område. 9203Axxx kan monteres i sikkert område samt i zone 2 / division 2 og sende signaler til sikkert område. Driver til styring af ON / OFF ventiler, akustiske alarmer og lysdioder placeret i sikkert område. Overvågning af interne fejlsituationer via det individuelle statusrelæ og / eller kollektivt elektronisk signal via power rail er konstrueret, udviklet og certificeret til brug i SIL 2 installationer iht. kravene i IEC Product Version

8 Teknisk karakteristik 1 grøn og 2 gule/røde LEDs i front indikerer normal drift og funktionsfejl. 2,6 kvac galvanisk isolation mellem indgang, udgang og forsyning Product Version

9 Applikationer Axxx Udgangssignaler: Kanal 1 Indgangssignaler: Kanal 2 Alarm Ventil Kanal 1 Power rail Statusrelæ-signal Rail, +24 VDC Rail, Gnd. Ingen forbindelse Ingen forbindelse Kanal 2 Alarm Ventil 54 Forsyningsspændinger: 31 Gnd Forsyning +19,2...31,2 VDC Modulstatus N.C. Modulstatus Forsyning via power raill Zone 2 / Cl. 1, div. 2, gr. A-D eller sikkert område Product Version

10 Applikationer Bxxx Udgangssignaler: Kanal 1 Indgangssignaler: Kanal 2 Alarm Ventil Kanal 1 Power rail Statusrelæ-signal Rail, +24 VDC Rail, Gnd. Ingen forbindelse Ingen forbindelse Kanal 2 Alarm Ventil 54 Forsyningsspændinger: 31 Gnd Forsyning +19,2...31,2 VDC Modulstatus N.C. Modulstatus Zone 0, 1, 2, 20, 21, 22, M1 & Cl. I/II/III, div. 1 gr. A-G Forsyning via power raill Zone 2 / Cl. 1, div. 2, gr. A-D eller sikkert område

11 PR 4501 Display- / programmeringsfront Funktionalitet Den enkle menustruktur og de forklarende hjælpe tekster leder dig automatisk gennem opsætningen og gør produktet meget enkelt at anvende. Se beskrivelse af funktioner og opsætningsmuligheder under afsnittet Programmering / betjening af trykknapper. Anvendelse Kommunikationsinterface til ændring af driftsparametre i Som fastmonteret display til visualisering af procesdata og status. Teknisk karakteristik: Fire liniers LCD-display, linie 1 (5,57 mm høj) viser hver kanals status (OK eller fejl). Linie 2 (3,33 mm høj) viser kanal 1 s udgang (ON / OFF), linie 3 (3,33 mm høj) viser kanal 2 s udgang (ON / OFF) og linie 4 viser, om modulet er SIL-låst. Statisk prik = SIL-låst og blinkende prik = ikke SIL-låst. Linie 4 viser også, om udgangen er aktiv. For at undgå uautoriseret brug kan konfigurationen beskyttes med et password Product Version

12 Påsætning / aftagning af PR4501/4511 1: Indsæt tappene på 4501/4511 i hullerne øverst på modulet. 2: Sving 4501/4511 på plads. Aftagning af 4501/4511 3: Tryk på udløserknap i bunden af 4501/4511 og sving 4501/4511 op Product Version

13 Bestillingsskema : 9203 Type Version Udgang Kanaler Indgang 9203 Non-Ex / zone 2...: A Ex-barriere [Ex ia] / Lav strøm...: 1 Enkelt...: A Dobbelt...: B Standard... : - PNP... : 1 zone 2...: B Høj strøm...: 2 Enkelt...: A NPN... : 2 Tilbehør Type Beskrivelse Display- / programmeringsfront Kommunikationsenhed Power rail Modulstop til power rail / DIN-skinne Power control unit Spændingsforsyning 24 V / 120 W - Ex nac Elektriske specifikationer Omgivelsesbetingelser Specifikationsområde C Lagringstemperatur C Kalibreringstemperatur C Relativ luftfugtighed... < 95% RH (ikke kond.) Kapslingsklasse... IP20 Installation i... Forureningsgrad 2 & måle- / overspændingskategori II Mekaniske specifikationer Mål, uden displayfront (HxBxD) x 23,5 x 104 mm Mål, med 4501 / 4511 (HxBxD) x 23,5 x 116 / 131 mm Vægt, ca g Vægt inkl / 4511 (ca.) g / 270 g DIN-skinnetype... DIN EN / 35 mm Ledningskvadrat (min. / max.)... 0,13...2,08 mm 2 / AWG flerkoret ledning Klemskruetilspændingsmoment... 0,5 Nm Vibration... IEC : ,2 Hz... ±1 mm 13, Hz... ±0,7 g Product Version

14 Fælles specifikationer: Forsyningsspænding... 19,2...31,2 VDC Max. forbrug... 3,5 W (2 kanaler) Sikring... 1,25 A T / 250 VAC Isolationsspændinger, test / drift Indgange / udgange / forsyning... 2,6 kvac / 250 VAC forstærket Udgang 1 til udgang ,5 kvac / 150 VAC forstærket Statusrelæ til forsyning... 1,5 kvac / 150 VAC forstærket Kommunikationsinterface... Kommunikationsenhed 4511 Programmeringsfront 4501 EMC-immunitetspåvirkning... < ±0,5% af span Udvidet EMC-immunitet: NAMUR NE 21, A kriterium, gniststøj... < ±1% af span 9203xxx NPN åben kollektor og mekanisk kontakt: Trig-niveau LOW... 2,0 VDC Trig-niveau HIGH... 4,0 VDC Max. ekstern spænding VDC Indgangsimpedans... 3,5 kω V åben indgang... 6,0 VDC 9203xxx PNP åben kollekor: Trig-niveau LOW... 8,0 VDC Trig-niveau HIGH... 10,0 VDC Max. ekstern spænding VDC Indgangsimpedans... 3,5 kω V åben indgang... 6,0 VDC 9203xxx1 PNP med pull-down modstand: Trig-niveau low... 8,0 VDC Trig-niveau high... 10,0 VDC Max. ekstern spænding VDC Indgangsimpedans... 3,5 kω 9203xxx2 NPN med pull-up modstand: Trig-niveau low... 2,0 VDC Trig-niveau high... 4,0 VDC Max. ekstern spænding VDC Indgangsimpedans... 3,5 kω Udgange: Udgangsripple... < 40 mv RMS Product Version

15 Udgangsbelastning: Klemme Vudgang ubelastet 9203x1Ax (1 kanal) / 9203x1Bx (2 kanaler) / / / Min. 24 V Min. 24 V Min. 24 V Vudgang. belastet Min. 12,5 V Min. 13,5 V Min. 14,5 V Iudg. max 35 ma 35 ma 35 ma [V] [ma] Klemmer: X41 X44 X41 X43 X41 X Product Version

16 Klemme Vudgang ubelastet 9203x2Ax (1 kanal) Min. 24 V Min. 24 V Min. 24 V Vudgang. belastet Min. 11,5 V Min. 9 V Min. 12,5 V Min. 10 V Min. 13,5 V Min. 11 V Iudg. max 50 ma 60 ma 50 ma 60 ma 50 ma 60 ma [V] [ma] Klemmer: X41 X44 X41 X43 X41 X Product Version

17 Relæudgang: Statusrelæ i sikkert område: Max. spænding VAC / 110 VDC Max. strøm... 0,5 A AC / 0,3 A DC Max. effekt... 62,5 VA / 32 W Godkendelser: EMC 2004/108/EF... EN LVD 2006/95/EF... EN c UL us, Standard for Safety... UL EAC TR-CU 020/ EN Marine: Det Norske Veritas, Ships & Offshore... Stand. f. Certific. No. 2.4 I.S. / Ex: ATEX 94/9/EF... KEMA 07ATEX0147 X IECEx... IECEx KEM X c FM us C INMETRO... NCC X CCOE... P337349/6 EAC Ex TR-CU 012/ RU C-DK.GB08.V Funktionel sikkerhed: SIL 2-certificeret via Full Assessment iht. IEC Product Version

18 Hardware- / softwarefejl Visning ved hardwarefejl Fejlsøgning Visning Årsag Test af kommunikation mellem 4501 / 9203 NO.CO Fejl i stikforbindelse EEprom-fejl - check konfiguration Hardwarefejl Hardwarefejl EEprom-fejl - check konfiguration FL.ER DE.ER FC.ER CO.ER Konfigurationsfejl eller crcmismatch, recoverykonfiguration er indlæst Ugyldig recoverykonfiguration i modulet Ugyldig kode-checksum i 4501 Ugyldig konfiguration (CRC eller data) Hardwarefejl CA.ER Fejl i fabrikskalibrering Hardwarefejl Hardwarefejl Hardwarefejl Hardwarefejl Hardwarefejl HW.ER OC.ER MS.ER MI.ER MC.ER HW-setup - konfigurations-mismatch Kommunikationsfejl i primær processorkontrol Primær intern forsyning uden for grænser Fejl i primær initialiseringsselvtest Fejl i primær flash eller ram selvtest Product Version

19 Tilslutninger Power rail forbindelser Forsyning og statusrelæ Fejl Gnd. +24 V NC NC Gnd. +24 V N.C. NC = Ingen forbindelse Indgange xxx: Kanal 1 Kontakt (6 V)* + NPN (6 V)* PNP (6 V)* PNP-indgang D ekstern R Kanal 2 Kontakt (6 V)* + NPN (6 V)* PNP (6 V)* NPN-indgang D ekstern R * 6 V ved åben indgang Product Version

20 Indgange xxx1: Kanal 1 Kontakt PNP PNP med pull-down Aktiv indgang R Kontakt med pull-down PNP PNP med pull-down Aktiv indgang Kanal R R Indgange xxx2: Kanal 1 Kontakt med NPN pull-up med pull-up NPN Aktiv indgang R R Kontakt med pull-down NPN med pull-up NPN Aktiv indgang Kanal R Product Version

21 Kanal 1 Udgange xxxx: Ventil, ON / OFF Akustisk alarm LED Kanal 2 Ventil, ON / OFF Akustisk alarm LED Product Version

22 NC* NC* V Modulstatus, Grøn CPU Kanal 1 status, Gul/Rød Kanal 2 status, Gul/Rød FLASH 44 R Ex3 Sikring 34 Statusrelæ N.C R Ex2 R Ex1 Indgang + 12 (6 V) Indgang, Gnd. Kanal R Ex3 Sikring R Ex2 Kontakt NPN PNP Kontakt NPN PNP ON OFF R Ex1 Indgang, Gnd. 14 (6 V) 13 Indgang xxx 1 Blokdiagram Udgang + Udgang, Gnd. Udgang + Udgang, Gnd. Power rail forbindelser Gnd. - Forsyning +24 VDC Statusrelæ N.C. Kanal 2 * NC = Ingen forbindelse Product Version

23 Visning af signalfejl uden displayfront Status Liste over LED- og fejlsignalvisninger Grøn LED Kanal 1: Gul / Rød Kanal 2: Gul / Rød Statusrelæ, N.C. Power rail signalstatus Modul OK Blinker Trukket OFF Ingen forsyning OFF OFF OFF Sluppet ON Modul defekt OFF Rød Rød Sluppet ON Kanal 1, udgang ON Blinker Gul Trukket OFF Kanal 1, udgang OFF Blinker OFF Trukket OFF Kanal 2, udgang ON Blinker Gul Trukket OFF Kanal 2, udgang OFF Blinker OFF Trukket OFF Dokumentation til rutediagram Generelt Programmering / betjening af trykknapper Når du skal konfigurere 9203, bliver du guidet igennem samtlige parametre og kan vælge netop de indstillinger, der passer til applikationen. Til hver menu findes en rullende hjælpetekst, som vises i displaylinie 3. Konfigurationen udføres ved hjælp af de 3 taster: 1 forøger talværdien eller vælger næste parameter 2 formindsker talværdien eller vælger forrige parameter 3 accepterer valget og går til næste menu Når konfigurationen er gennemført, returneres til normaltilstand 1.0. Tryk og hold 3 tasten nede for at gå til forrige menu eller normaltilstand (1.0) uden at gemme de ændrede tal eller parametre. Hvis ingen taster har været aktiveret i 1 minut, returnerer displayet til normaltilstand (1.0) uden at gemme de ændrede tal eller parametre Product Version

24 Uddybende forklaringer Passwordbeskyttelse: Programmeringsadgang kan forhindres ved indkodning af et password. Passwordet gemmes i modulet, så sikkerheden mod uønskede ændringer er så høj som muligt. Default password 2008 giver adgang til alle programmeringsmenuer. Signal- og modulfejlsinformation via displayfront 4501 Displayfronten 4501 kan konfigureres til at vise udgangsstatus, udgangsstrøm eller TAG.-nr. for begge kanaler. Ved hardwarefejl vises en forklarende hjælpetekst i displayet. Avancerede funktioner Enheden giver adgang til en række avancerede funktioner, der nås ved at svare yes til punktet adv.set. Display setup: Her kan man justere kontrast og baggrundsbelysning. Opsætning af TAG-nummer med 5 alfanumeriske karakterer. Valg af funk tionsvisning i linie 2 og 3 på displayet; der vælges mellem visning af udgangsstatus, udgangsstrøm og TAG-nr. Vælges ALT skifter displayet mellem de forskellige visningsmuligheder. Password: Her kan vælges et password mellem 0000 og 9999 til beskyttelse mod uautoriserede ændringer. Enheden leveres default uden password. Sprog: Der kan i menuen LANG vælges mellem 7 forskellige sprogvarianter af hjælpetekster, der fremkommer i menuen. Der kan vælges mellem UK, DE, FR, IT, ES, SE og DK. Safety Integrity Level (SIL): Se Safety Manual (engelsk) for yderligere information Product Version

25 Rutediagram Hvis ingen taster har været aktiveret i 1 minut, returnerer displayet til normaltilstanden 1.0 uden at gemme eventuelle konfigurationsændringer. 1 Forøgelse af værdi / vælg næste parameter 2 Formindskelse af værdi / vælg forrige parameter 3 Accepter valget og gå til næste menu Holde 3 går til forrige menu / returnerer til 1.0 uden at gemme Power up Hvis SIL-låst direkte til [EN.SIL] ON OFF NO PASSW. Txt NO YES ADV.SET Txt 2 DIR INV 3 DIR CH1.FUN Txt 7 3 DIR INV DIR CH2.FUN Txt 7 3 Til normaltilstand 1.0 YES 3 ADV.SET Txt = Normaltilstand Linie 1 viser status for kanal 1 og kanal 2. Linie 2 viser udgangsstatus, udgangsstrøm eller TAG.-nr. for kanal 1. Linie 3 viser udgangsstatus, udgangsstrøm eller TAG.-nr. for kanal 2. Linie 4 indikerer om modulet er SIL-låst. 1.1 = Kun hvis beskyttet med password 1.2 = Kun hvis password er valgt. Linie 1 symboler: = OK. Blinkende = fejl. Linie 2 og 3 symboler: ON = kanal 1 ON OFF = kanal 2 OFF. Linie 4 symboler: Statisk prik = SIL-låst. Blinkende prik = ikke SIL-låst. = udgangen er aktiv. Rød tekst viser safety parametre i en SILkonfiguration. Se Safety Manual for yderligere information Product Version

26 Rutediagram, Avancerede indstillinger (ADV.SET) DISP, PASS, LANG, SIL DISP SETUP Txt CONTRA Txt LIGHT Txt A TAG1 VALVE 5 Txt A TAG2 VALVE 6 Txt 11 ALT LOAD TAG D.OUT 3 LOAD 3 DISP Txt 12 PASS SETUP Txt 06 YES NO 3 YES 3 EN.PASS Txt NEW.PAS Txt 16 NO LANG SETUP Txt 06 DE, DK, ES, FR, IT, SE, UK 3 UK LANGUA Txt 17 3 Til normaltilstand 1.0 SIL SETUP Txt 06 YES NO 3 YES EN.SIL Txt NEW.PAS Txt 16 NO LOCK OPEN 3 LOCK CONFIG Txt 13 Verificer SIL-konfiguration SIL.OK Product Version

27 [01] [02] [06] [07] [09] [10] [11] [12] [13] [14] [15] [16] [17] [20] [21] [22] Rullende hjælpetekster i displaylinie 3 Angiv korrekt password Gå til avanceret opsætningsmenu? Gå til valg af sprog Gå til password-indstilling Gå til displayopsætning Gå til valg af SIL-låsning Vælg direkte signalbehandling Vælg inverteret signalbehandling Juster LCD-kontrast Juster LCD-baggrundsbelysning Angiv et 5-karakters TAG-nr. Udgangsstatus vises i display Udgangsbelastning vises i display TAG-nr. vises i display Skiftende værdier vises i display Konfigurationens SIL-status (åben / låst) Vælg at SIL-låse konfigurationen Aktiver passwordbeskyttelse? Angiv nyt password Vælg sprog Ingen kommunikation - kontroller stikforbindelser Fejl i EEprom - kontroller konfiguration Hardware-fejl Product Version

28 Appendix IECEx installation drawing ATEX installation drawing FM installation drawing Inmetro installation drawing safety manual Product Version

29 LERBAKKEN 10, 8410 RØNDE DENMARK IECEx Installation drawing 9203QI01 For safe installation of 9203 the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. For Installation in Zone 2 / Division 2 the following must be observed. The 4501 programming module is to be used solely with PRelectronics modules. It is important that the module is undamaged and has not been altered or modified in any way. Only 4501 modules free of dust and moisture shall be installed. IECEx Certificate: IECEx KEM X Marking 9203Bxxx Marking 9203Axxx Standards [Ex ia Ga] IIC/IIB/IIA Ex na nc IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Ex na nc IIC T4 Gc IEC :2010, IEC :2011, IEC :2011 Type Installation Current Output Channels Input Single :A Standard : Non Ex / Zone 2 :A Low current :1 Double :B PNP : 1 Ex-Barrier / Zone 2 :B High current :2 Single :A NPN : 2 Installation notes. Install in pollution degree 2, overvoltage category II as defined in IEC Do not separate connectors when energized and an explosive gas mixture is present. Do not mount or remove modules from the Power Rail when an explosive gas mixture is present. Disconnect power before servicing. The wiring of unused terminals is not allowed. In type of protection [Ex ia Da] the parameters for intrinsic safety for gas group IIB are applicable. For installation in Zone 2, the module shall be installed in an enclosure in type of protection Ex n or Ex e, providing a degree of protection of at least IP54. Cable entry devices and blanking elements shall fulfill the same requirements. For installation on Power Rail in Zone 2, only Power Rail type 9400 supplied by Power Control Unit type 9410 (IECEx Certificate of Conformity IECEx KEM X ) is allowed. Revision date: Version Revision V6 R0 Prepared by: PB Page: 1/ Product Version

30 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QI Bxxx Installation: Hazardous area Non Hazardous area Zone 0, 1, 2, 20, 21, 22 or Zone 2-20 Ta 60ºC Power Rail 9203B Supply / Input (terminal 11,12,13,14) (terminal 31,32,33,34) (terminal 91,92,93,94,95) Um: 253V, max. 400Hz Terminal (31,32) Terminal (11,12 and 13,14) Supply: Input: Voltage VDC Voltage max 28 VDC Power max. 3.5 W Trig: NPN Low < 2 V, High > 4 V Trig: PNP Low < 8 V, High > 10 V Terminal (33,34) Status Relay: Non Hazardous location Zone 2 installation Voltage max. 125 VAC / 110 VDC 32 VAC / 32 VDC Power max VA / 32 W 16 VA / 32 W Current max. 0.5 AAC / 0.3 ADC 0.5 AAC / 1 ADC Revision date: Version Revision V6 R0 Prepared by: PB Page: 2/ Product Version

31 9203QI01 LERBAKKEN 10, 8410 RØNDE DENMARK 9203B1A, 9203B1B Terminal 41-42/51-52 Co Lo Lo/Ro 9203B2A Terminal Co Lo Lo/Ro Uo 28V IIC 80nF 4.2mH 54µH/Ω Uo 28V IIC 80nF 2.69mH 44µH/Ω Io 93 ma IIB 640nF 16.8mH 218µH/Ω Io 115mA IIB 640nF 10.8mH 176µH/Ω Po 0.65W IIA 2.1µF 32.6mH 436µH/Ω Po 0.81W IIA 2.1µF 20.8mH 353µH/Ω I 3.76µF 32.6mH 436µH/Ω I 3.76µF 20.8mH 353µH/Ω 9203B1A, 9203B1B Terminal 41-43/51-53 Co Lo Lo/Ro 9203B2A Terminal Co Lo Lo/Ro Uo 28V IIC 80nF 3.5mH 54µH/Ω Uo 28V IIC Io 100mA IIB 640nF 14.2mH 218µH/Ω Io 125mA IIB 640nF 9.1mH 163µH/Ω Po 0.70W IIA 2.1µF 27.6mH 436µH/Ω Po 0.88W IIA 2.1µF 17.6mH 327µH/Ω I 3.76µF 27.6mH 436µH/Ω I 3.76µF 17.6mH 327µH/Ω 9203B1A,9203B1B Terminal 41-44/51-54 Co Lo Lo/Ro 9203B2A Terminal Co Lo Lo/Ro Uo 28V IIC 80nF 2.9mH 46µH/Ω Uo 28V IIC Io 110mA IIB 640nF 11.8mH 184µH/Ω Io 135mA IIB 640nF 7.8mH 150µH/Ω Po 0.77W IIA 2.1µF 22.8mH 369µH/Ω Po 0.95W IIA 2.1µF 15.1mH 301µH/Ω I 3.76µF 22.8mH 369µH/Ω I 3.76µF 15.1mH 301µH/Ω Revision date: Version Revision V6 R0 Prepared by: PB Page: 3/ Product Version

32 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QI Axxx Installation Non Classified area or Zone Power Rail 9203A Terminal (31,32) Terminal (11,12 and 13,14) Supply: Input: Voltage VDC Voltage max 28 VDC Power max. 3.5 W Trig: NPN Low < 2 V, High > 4 V Trig: PNP Low < 8 V, High > 10 V Terminal (33,34) Status Relay: Non Hazardous location Zone 2 installation Voltage max. 125 VAC / 110 VDC 32 VAC / 32 VDC Power max VA / 32 W 16 VA / 32 W Current max. 0.5 AAC / 0.3 ADC 0.5 AAC / 1 ADC Terminal ( / ) Umax 28 V Imax 135 ma Pmax 0.95 W Revision date: Version Revision V6 R0 Prepared by: PB Page: 4/ Product Version

33 LERBAKKEN 10, 8410 RØNDE DENMARK ATEX installationstegning 9203QA01 For sikker installation af 9203 skal følgende overholdes: Modulet må kun installeres af kvalificerede personer, som er bekendt med national og international lovgivning, direktiver og standarder i det land, hvor modulet skal installeres. Produktionsår fremgår af de to første cifre i serienummeret For installation i zone 2 / division 2 skal følgende overholdes: Den aftagelige displayfront til programmering 4501 er udelukkende beregnet til brug på PR electronics moduler. Det er vigtigt, at displayet er ubeskadiget, ikke ombygget eller på anden måde forandret må kun anvendes, hvis det er fri for støv og/eller fugt. ATEX-certifikat KEMA 07ATEX 0147 X Mærkning 9203B II (1) G [Ex ia Ga] IIC/IIB/IIA II 3G Ex na nc IIC T4 Gc I (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Mærkning 9203A II 3G Ex na nc IIC T4 Gc Standarder EN : 2012, EN : 2012, EN : 2010 Type Installation Strømudgang Kanaler Indgang Enkelt : A Standard : Lav strøm : 1 Non-Ex / Zone 2 : A Dobbelt : B PNP : 1 Ex-barriere / Zone 2 : B Høj strøm : 2 Enkelt : A NPN : 2 Installationsforskrifter Installer i forureningsgrad 2, overspændingskategori II som defineret i EN Monter/demonter ikke stik, når forsyning er tilsluttet og der forefindes en eksplosionsfarlig gasblanding. Monter/demonter ikke modulet på Power Rail, når der forefindes en eksplosionsfarlig gasblanding. Afbryd forsyning før udførelse af vedligehold og reparation. Fortrådning i ubenyttede terminaler er ikke tilladt. Ved beskyttelsesmetode [Ex ia Da] er parametrene for egensikkerhed for gasgruppe IIB gældende. For installation i zone 2 skal modulet installeres i et hus, som har beskyttelsestype Ex n eller Ex e, og som giver en IP-beskyttelse på mindst IP54. Kabelforskruninger og blindstik skal opfylde samme krav. Ved installation på Power Rail type 9400 i zone 2 er det kun tilladt at forsyne Power Rail ved brug af 9410 Power Control Unit (Type Examination Certificate KEMA 07ATEX0152 X). Revision date: Version Revision Prepared by: Page: V6 R0-DK01 PB 1/ Product Version

34 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QA Bxxx installation: Ex-område Zone 0,1,2, 20, 21, 22 Ikke Ex-område eller Zone 2-20 Ta 60ºC B Power Rail Forsyning / Indgang (klemme 11,12,13,14) (klemme 31,32,33,34) (klemme 91,92,93,94,95) Um: 253V, max. 400 Hz Klemme (31,32) Klemme (11,12 og 13,14) Forsyning: Indgang: Spænding 19,2 31,2 VDC Spænding Max 28 VDC Max. forbug 3,5 W Trig: NPN Low < 2 V, High > 4 V Trig: PNP Low < 8 V, High > 10 V Klemme (33,34) Statusrelæ: Ikke Ex-område Zone 2 installation Max. spænding 125 VAC / 110 VDC 32 VAC / 32 VDC Max. forbrug. 62,5 VA / 32 W 16 VA / 32 W Max.strøm 0.5 AAC / 0.3 ADC 0,5 AAC / 1 ADC Revision date: Version Revision Prepared by: Page: V6 R0-DK01 PB 2/ Product Version

35 9203QA01 LERBAKKEN 10, 8410 RØNDE DENMARK 9203B1A, 9203B1B Terminal 41-42/51-52 Co Lo Lo/Ro 9203B2A Terminal Co Lo Lo/Ro Uo 28V IIC 80nF 4.2mH 54µH/Ω Uo 28V IIC 80nF 2.69mH 44µH/Ω Io 93 ma IIB 640nF 16.8mH 218µH/Ω Io 115mA IIB 640nF 10.8mH 176µH/Ω Po 0.65W IIA 2.1µF 32.6mH 436µH/Ω Po 0.81W IIA 2.1µF 20.8mH 353µH/Ω I 3.76µF 32.6mH 436µH/Ω I 3.76µF 20.8mH 353µH/Ω 9203B1A, 9203B1B Terminal 41-43/51-53 Co Lo Lo/Ro 9203B2A Terminal Co Lo Lo/Ro Uo 28V IIC 80nF 3.5mH 54µH/Ω Uo 28V IIC Io 100mA IIB 640nF 14.2mH 218µH/Ω Io 125mA IIB 640nF 9.1mH 163µH/Ω Po 0.70W IIA 2.1µF 27.6mH 436µH/Ω Po 0.88W IIA 2.1µF 17.6mH 327µH/Ω I 3.76µF 27.6mH 436µH/Ω I 3.76µF 17.6mH 327µH/Ω 9203B1A, 9203B1B Terminal 41-44/51-54 Co Lo Lo/Ro 9203B2A Terminal Co Lo Lo/Ro Uo 28V IIC 80nF 2.9mH 46µH/Ω Uo 28V IIC Io 110mA IIB 640nF 11.8mH 184µH/Ω Io 135mA IIB 640nF 7.8mH 150µH/Ω Po 0.77W IIA 2.1µF 22.8mH 369µH/Ω Po 0.95W IIA 2.1µF 15.1mH 301µH/Ω I 3.76µF 22.8mH 369µH/Ω I 3.76µF 15.1mH 301µH/Ω Revision date: Version Revision Prepared by: Page: V6 R0-DK01 PB 3/ Product Version

36 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QA Axxx installation: Ikke-klassificeret område eller Zone Power Rail 9203A Klemme (31,32) Klemme (11,12 og 13,14) Forsyning: Indgang: Spænding 19,2 31,2 VDC Spænding Max 28 VDC Max. forbrug 3,5 W Trig: NPN Low < 2 V, High > 4 V Trig: PNP Low < 8 V, High > 10 V Klemme (33,34) Statusrelæ: Ikke Ex-område Zone 2 installation Max. spænding 125 VAC / 110 VDC 32 VAC / 32 VDC Max. forbrug 62,5 VA / 32 W 16 VA / 32 W Max. strøm 0,5 AAC / 0,3 ADC 0,5 AAC / 1 ADC Klemme ( / ) Umax 28 V Imax 135 ma Pmax 0,95 W Revision date: Version Revision Prepared by: Page: V6 R0-DK01 PB 4/ Product Version

37 FM Installation Drawing LERBAKKEN 10, 8410 RØNDE DENMARK FM Installation drawing 9203QF01 For safe installation of 9203 the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. For Installation in Zone 2 / Division 2 the following must be observed. The 4501 programming module is to be used solely with PRelectronics modules. It is important that the module is undamaged and has not been altered or modified in any way. Only 4501 modules free of dust and moisture shall be installed. c-fm-us Certificate Type Installation Current Output Channels Input Single :A Standard : Non Ex / Zone 2 :A Low current :1 Double :B PNP : 1 Ex-Barrier / Zone 2 :B High current :2 Single :A NPN : 2 Installation notes: The installation and wiring shall be in accordance with the Canadian Electrical Code for Canada and National Electrical Code NFPA 70, Article 500 or 505 for installation in USA. The module must be supplied from a Power Supply having double or reinforced insulation. The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends. For installation on the 9400 Power Rail the power must be supplied from Power Control Module Unit Install in pollution degree 2, overvoltage category II. The module must be installed in an enclosure suitable for the environment for which it is used. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure according to the regulations in the CEC for Canada or NEC for USA. The module is galvanically isolated and does not require grounding. Use 60 / 75 ºC copper conductors with wire size AWG: (26-14). The maximum internal Power dissipation for adjacent modules is assumed to be max. 2W each. Warning: Substitution of components may impair intrinsic safety and / or suitability for Div. 2 / Zone 2. Warning: To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. Warning: Do not mount or remove modules from the Power Rail when an explosive gas mixture is present. Revision date: Version Revision V6R0 Prepared by: PB Page: 1/ Product Version

38 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QF Bxxx Installation: Hazardous area Class I/II/III, Division 1, Group A,B,C,D,E,F,G or Class I, Zone 0/1 Group IIC, [AEx ia] IIC or or Class I, Zone 0/1 Group IIC, [Ex ia] IIC Non Hazardous Area or Class I, Division 2, Group A,B,C,D T4 or Class I, Zone 2 Group IIC T4-20 Ta 60ºC 4501 Simple Apparatus or Intrinsically safe apparatus with entity parameters: Vmax (Ui) Vt (Uo) Imax (Ii) It (Io) Pi Pt(Po) Ca(Co) Ccable + Ci La(Lo) Lcable + Li Power Rail Supply / Input (terminal 11,12,13,14) (terminal 31,32,33,34) (terminal 91,92,93,94,95) Um: 253V, max. 400Hz Terminal (31,32) Terminal (11,12 and 13,14) Supply: Input: Voltage VDC Voltage max 28 VDC Power max. 3.5 W Trig: NPN Low < 2 V, High > 4 V Trig: PNP Low < 8 V, High > 10 V Terminal (33,34) Status Relay: Non Hazardous location: Division 2 or Zone 2 installation: Voltage max. 125 VAC / 110 VDC 32 VAC / 32VDC Power max VA / 32 W 16 VA / 32 W Current max. 0.5 AAC / 0.3 ADC 0.5 AAC / 1 ADC Revision date: Version Revision V6R0 Prepared by: PB Page: 2/ Product Version

39 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QF01 Module 9203B1A & 9203B1B Lo/Ro or Module 9203B2A Lo/Ro or Co/Ca Lo/La Co/Ca Lo/La Terminal / La/Ra Terminal La/Ra Uo/Voc 28 V IIC or A,B 80 nf 4.2 mh 54 μh/ω Uo/Voc 28 V IIC or A,B 80 nf 2.69 mh 44 μh/ω Io/Isc 93 ma IIB or C,E,F 640 nf 16.8 mh 218 μh/ω Io/Isc 115 ma IIB or C,E,F 640 nf 10.8 mh 176 μh/ω Po 0.65 W IIA or D,G 2.1 μf 32.6 mh 436 μh/ω Po 0.81 W IIA or D,G 2.1 μf 20.8 mh 353 μh/ω Module 9203B1A & 9203B1B Lo/Ro or Module 9203B2A Lo/Ro or Co/Ca Lo/La Co/Ca Lo/La Terminal / La/Ra Terminal La/Ra Uo/Voc 28 V IIC or A,B 80 nf 3.5 mh 50 μh/ω Uo/Voc 28 V IIC or A,B Io/Isc 100 ma IIB or C,E,F 640 nf 14.2 mh 201 μh/ω Io/Isc 125 ma IIB or C,E,F 640 nf 9.1 mh 163 μh/ω Po 0.70 W IIA or D,G 2.1 μf 27.6 mh 402 μh/ω Po 0.88 W IIA or D,G 2.1 μf 17.6 mh 327 μh/ω Module 9203B1A & 9203B1B Lo/Ro or Module 9203B2A Lo/Ro or Co/Ca Lo/La Co/Ca Lo/La Terminal / La/Ra Terminal La/Ra Uo/Voc 28 V IIC or A,B 80 nf 2.9 mh 46 μh/ω Uo/Voc 28 V IIC or A,B Io/Isc 110 ma IIB or C,E,F 640 nf 11.8 mh 184 μh/ω Io/Isc 135 ma IIB or C,E,F 640 nf 7.8 mh 150 μh/ω Po 0.77 W IIA or D,G 2.1 μf 22.8 mh 369 μh/ω Po 0.95 W IIA or D,G 2.1 μf 15.1 mh 301 μh/ω 9203Axxx Installation: Non Classified area or Zone 2 or Division Power Rail 9203A Terminal (31,32) Terminal (11,12 and 13,14) Supply: Input: Voltage VDC Voltage max 28 VDC Power max. 3.5 W Trig: NPN Low < 2 V, High > 4 V Trig: PNP Low < 8 V, High > 10 V Terminal (33,34) Status Relay: Non Hazardous location Zone 2 installation Voltage max. 125 VAC / 110 VDC 32 VAC / 32 VDC Power max VA / 32 W 16 VA / 32 W Current max. 0.5 AAC / 0.3 ADC 0.5 AAC / 1 ADC Revision date: Version Revision V6R0 Prepared by: PB Page: 3/ Product Version

40 INMETRO Installation Drawing LERBAKKEN 10, 8410 RØNDE DENMARK 9203QB01 INMETRO Desenhos para Instalação Para instalação segura do 9203B o manual seguinte deve ser observado. O módulo deve ser instalado somente por profissionais qualificados que estão familiarizados com as leis nacionais e internacionais, diretrizes e normas que se aplicam a esta área. Ano de fabricação pode ser obtido a partir dos dois primeiros dígitos do número de série Para a instalação na Zona 2 o seguinte deve ser observado. O módulo de programação de 4501, deve ser utilizado apenas com os módulos PRelectronics. É importante que o módulo esteja intacto e não tenha sido alterado ou modificado de qualquer maneira. Apenas os módulos 4501 livres de poeira e umidade devem ser instalados. INMETRO Certificado NCC X Marcas [Ex ia Ga] IIC/IIB/IIA Ex na nc IIC T4 Gc [Ex ia Da] IIIC Normas IEC :2005, IEC :2011, IEC :2011 IEC :2006 Notas de instalação: Instalação em grau de poluição 2, categoria de sobretensão II conforme definido no IEC Não separe conectores quando energizado ou quando uma mistura de gás explosivo estiver presente. Não monte ou remova módulos do trilho de alimentação quando uma mistura explosiva de gás estiver presente. Desligue a alimentação antes da manutenção. A fiação de terminais sem uso não é permitida. A fonte de Loop e terminais de entrada de corrente para o mesmo canal não deve ser aplicada ao mesmo tempo. Em tipo de proteção [Ex ia Da] os parâmetros para a segurança intrínseca para grupo de gás IIB são aplicáveis. Para a instalação em Zona 2, o módulo deve ser instalado em um invólucro certificado conforme as normas da série ABNT NBR IEC que proporcione um grau de proteção de pelo menos IP54. Dispositivos de entrada de cabo e elementos de vedação devem cumprir com os mesmos requisitos. Para a instalação de trilho de energia na Zona 2, apenas o trilho de alimentação Rail 9400 fornecido pela Unidade de Controle de Potência 9410 é permitido. Revision date: Version Revision V5 R0 Prepared by: PB Page: 1/ Product Version

41 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QB01 Área de Risco Área de não Risco Zona 0, 1, 2, 20, 21, 22 ou Zona 2-20 Ta 60ºC TRILHO DE ENERGIA 9203 Fonte / Entrada (terminais 11,12,13,14) (terminais 31,32,33,34) (terminais 91,92,93,94,95) Um: 253 V, máx. 400 Hz Terminal (31,32) Terminais (11,12 e 13,14) Fonte: Entrada: Voltagem 19,2 31,2 VDC Voltagem máx. 28,VDC Potência máx. 3,5 W Gatilho: NPN Baixo < 2,V, Alto > 4,V Gatilho: PNP Baixo < 8,V, Alto > 10,V Terminais (33,34) Relê de Estado: Área de não Risco Instalação Zona 2 Voltagem máx. 125 VAC / 110 VDC 32 VAC / 32 VDC Potência máx. 62,5 VA / 32 W 16 VA / 32 W Corrente máx. 0,5 AAC / 0,3 ADC 0,5 AAC / 1 ADC Revision date: Version Revision V5 R0 Prepared by: PB Page: 2/ Product Version

42 LERBAKKEN 10, 8410 RØNDE DENMARK 9203QB B1A, 9203B1B Terminais 41-42/51-52 Co Lo Lo/Ro 9203B2A Terminais Co Lo Lo/Ro Uo 28V IIC 80nF 4.2mH 54µH/Ω Uo 28V IIC 80nF 2.69mH 44µH/Ω Io 93 ma IIB 640nF 16.8mH 218µH/Ω Io 115mA IIB 640nF 10.8mH 176µH/Ω Po 0.65W IIA 2.1µF 32.6mH 436µH/Ω Po 0.81W IIA 2.1µF 20.8mH 353µH/Ω 9203B1A, 9203B1B Terminais 41-43/51-53 Co Lo Lo/Ro 9203B2A Terminais Co Lo Lo/Ro Uo 28V IIC 80nF 3.5mH 50µH/Ω Uo 28V IIC Io 100mA IIB 640nF 14.2mH 201µH/Ω Io 125mA IIB 640nF 9.1mH 163µH/Ω Po 0.70W IIA 2.1µF 27.6mH 402µH/Ω Po 0.88W IIA 2.1µF 17.6mH 327µH/Ω 9203B1A,9203B1B Terminais 41-44/51-54 Co Lo Lo/Ro 9203B2A Terminais Co Lo Lo/Ro Uo 28V IIC 80nF 2.9mH 46µH/Ω Uo 28V IIC Io 110mA IIB 640nF 11.8mH 184µH/Ω Io 135mA IIB 640nF 7.8mH 150µH/Ω Po 0.77W IIA 2.1µF 22.8mH 369µH/Ω Po 0.95W IIA 2.1µF 15.1mH 301µH/Ω Revision date: Version Revision V5 R0 Prepared by: PB Page: 3/3

43 Safety manual Solenoid / Alarm Driver 9203 This safety manual is valid for the following product versions: Version No. V5R0

44

45 0. CONTENTS 9203 Solenoid / Alarm Driver Safety Manual 1. Observed standards Acronyms and abbreviations Purpose of the product Assumptions and restrictions for use of the product Basic safety specifications Associated equipment Safety output Safety input Failure rates Safe parameterisation Installation in hazardous areas Functional specification of the safety functions Functional specification of the non-safety functions Safety parameters Hardware and software configuration Failure category Periodic proof test procedure Procedures to repair or replace the product Maintenance Documentation for routing diagram In general Further explanations Password protection Advanced functions Display setup Password Language Power rail Safety integrity level Safe parameterisation - user responsibility Safety-related configuration parameters Verification procedure If no password is set If password is set Functional test Fault reaction and restart condition User interface Scrolling help texts in display line Routing diagram - Advanced settings (ADV.SET) Connections diagram Version No. V5R0 1

46 Safety Manual 1. Observed standards 9203 Solenoid / Alarm Driver Standard IEC IEC :2000 IEC :1998 IEC :2008 Description Functional Safety of electrical / electronic / programmable electronic safety-related systems Part 2: Requirements for electrical / electronic / programmable electronic safety-related systems Part 3: Software requirements Immunity requirements for safety-related systems 2. Acronyms and abbreviations Acronym / Abbreviation Designation Description Element PFD PFH SFF SIF SIL Probability of Failure on Demand Probability of dangerous Failure per Hour Safe Failure Fraction Safety Integrity Function Safety Integrity Level Term defined by IEC as part of a subsystem comprising a single component or any group of components that performs one or more element safety functions This is the likelihood of dangerous safety function failures occurring on demand. The term Probability is misleading, as IEC defines a Rate. Safe Failure Fraction summarises the fraction of failures which lead to a safe state and the fraction of failures which will be detected by diagnostic measures and lead to a defined safety action. Function that provides fault detection (to ensure the necessary safety integrity for the safety functions) The international standard IEC specifies four discrete safety integrity levels (SIL 1 to SIL 4). Each level corresponds to a specific probability range regarding the failure of a safety function. 2 Version No. V5R0

47 9203 Solenoid / Alarm Driver Safety Manual 3. Purpose of the product The 9203Bxxx can be mounted in the safe area or in zone 2 / div. 2 and transmit signals to zone 0, 1, 2 and zone 20, 21, 22 including M1 mining / Class I/II/III, Div. 1, Gr. A-G. Ex driver for the control of ON / OFF solenoids, acustic alarms and LEDs mounted in the hazardous area. The 9203Axxx can be mounted in the safe area or zone 2 / div. 2 and transmit signals to non-hazardous area. Driver for the control of ON / OFF solenoids, acustic alarms and LEDs mounted in safe area. The 9203 is controlled by an NPN/PNP signal or a switch signal. Monitoring of internal error events via the individual status relay and/or a collective electronic signal via the power rail. The 9203 has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC Assumptions and restrictions for use of the product 4.1 Basic safety specifications Operational temperature range C Storage temperature range C Power supply type, min... Double or reinforced Supply voltage VDC Mounting area... Zone 2 / Division 2 or safe area Mounting environment... Pollution degree 2 or better 4.2 Associated equipment Safety output The safety output shall be connected to the equipment with a minimum load of 10 KΩ Safety input The safety input signal frequency shall not be higher than 20 Hz, and the pulse length shall not be shorter than 25 ms. 4.3 Failure rates The basic failure rates from the Siemens standard SN are used as the failure rate database. Failure rates are constant, wear-out mechanisms are not included. External power supply failure rates are not included. Version No. V5R0 3

48 Safety Manual 9203 Solenoid / Alarm Driver 4.4 Safe parameterisation The user is responsible for verifying the correctness of the configuration parameters. (See section 14 Safe parameterisation - user responsibility). Manual override may not be used for safety applications. 4.5 Installation in hazardous areas The IECex Installation drawing, ATEX Installation drawing, INMETRO Installation drawing and FM Installation drawing shall be followed if the products are installed in hazardous areas. 5. Functional specification of the safety functions Driver for the control of ON / OFF solenoids, acou stic alarms and LEDs. 6. Functional specification of the non-safety functions The status relay (terminal 33 and 34), error signal on power rail (terminal 91) and LED outputs are not suitable for use in any Safety Instrumented Function. 7. Safety parameters Probability of dangerous Failure per Hour (PFH) 9203x1xx 4.30E-08 Note x2xx 4.60E-08 Probability of failure on demand (PFD) - 1 year proof test interval 2.73E E-04 Proof test interval (10% of loop PFD) 5 years 4 years Safe Failure Fraction 91% 91% Demand response time <10 ms Demand mode High Demand rate 1000 s Mean Time To Repair (MTTR) 24 hours Diagnostic test interval 10 seconds Hardware Fault Tolerance (HFT) 0 Component Type B SIL capability SIL 2 Description of the Safe State De-energised Note 1 : The 9203 contains no lifetime limiting components, therefore the PFH figures are valid for up to 12 years, according to IEC Version No. V5R0

49 9203 Solenoid / Alarm Driver Safety Manual 8. Hardware and software configuration All configurations of software and hardware versions are fixed from factory, and cannot be changed by end-user or reseller. This manual only covers products labelled with the product version (or range of versions) specified on the front page. 9. Failure category Failure category Failure rates (1/h) 9203x1xx 9203x2xx Fail Safe Detected 0.00E E+00 Fail Safe Undetected 4.77E E-07 Fail Dangerous Detected 0.00E E+00 Fail Dangerous Undetected 4.30E E Periodic proof test procedure Step Action 1 Bypass the safety PLC or take other appropriate action to avoid a false trip 2 Connect a simulator identical to the input setup 3 Perform an ON / OFF signal for each channel 4 Observe whether the output channel acts as expected 5 Restore the input terminals to full operation Remove the bypass from the safety PLC or otherwise restore normal 6 operation This test will detect approximately 95% of possible du (dangerous undetected) failures in the device. The proof test is equivalent to the functional test. 11. Procedures to repair or replace the product Any failures that are detected and that compromise functional safety should be reported to the sales department at PR electronics A/S. Repair of the device and replacement of circuit breakers must be done by PR electronics A/S only. 12. Maintenance No maintenance required. Version No. V5R0 5

50 Safety Manual 9203 Solenoid / Alarm Driver 13. Documentation for routing diagram The routing diagram is shown in section In general When configuring the 9203, you will be guided through all parameters and you can choose the settings which fit the application. For each menu there is a scrolling help text which is automatically shown in line 3 on the display. Configuration is carried out by use of the 3 function keys: 1 will increase the numerical value or choose the next parameter 2 will decrease the numerical value or choose the previous parameter 3 will accept the chosen value and proceed to the next menu When configuration is completed, the display will return to the default state 1.0. Pressing and holding 3 will return to the previous menu or return to the default state (1.0) without saving the changed values or parameters. If no key is activated for 1 minute, the display will return to the default state (1.0) without saving the changed values or parameters Further explanations Password protection Access to the configuration can be blocked by assigning a password. The password is saved in the device in order to ensure a high degree of protection against unauthorised modifications to the configuration. Default password 2008 allows access to all configuration menus. Password protection is mandatory in SIL applications Advanced functions The unit gives access to a number of advanced functions which can be reached by answering Yes to the point adv.set. 6 Version No. V5R0

51 9203 Solenoid / Alarm Driver Safety Manual Display setup Here you can adjust the brightness contrast and the backlight. Setup of tag numbers with 5 alphanumerics. Selection of functional readout in line 2 and 3 of the display - choose between readout of digital output or tag no. When selecting ALT the readout toggles between digital output and tag no Password Here you can choose a password between 0000 and 9999 in order to protect the device against unauthorised modifications to the configuration. The device is delivered default without password Language In the menu LANG you can choose between 7 different language versions of help texts that will appear in the menu. You can choose between UK, DE, FR, IT, ES, SE and DK Power rail In the menu RAIL you can choose if errors in the device are transmitted to the central surveillance in the PR 9410 power control unit Safety integrity level See Safe parameterisation - user responsibility Version No. V5R0 7

52 Safety Manual 9203 Solenoid / Alarm Driver 14 Safe parameterisation - user responsibility 14.1 Safety-related configuration parameters Parameters Value Description CH1.FUN DIR / INV Direct / inverted channel function CH2.FUN. DIR / INV Direct / inverted channel function PASSW New password The above safety-related configuration parameters are marked in red text in the routing diagrams and must be verified by the user in a SILconfiguration Verification procedure The verification is done using the display / programming front PR 4501 by following the procedure described below If no password is set Action Display shows 1 Press OK ADV.SET 2 Set (ADV.SET) to Yes and press OK DISP SETUP 3 Step down to (SIL SETUP) and press OK EN.SIL 4 Set (EN SIL) to YES and press OK NEW.PASS 5 Set password to a number between 0 and 9999 and press OK (At this time the device starts operating in SIL mode with the entered configuration parameters!) 6 Press OK to confirme verification of the OPEN-LOCK in the display Verify OPEN briefly LOCK* CH1.FUN 7 Verify Channel 1 function and press OK CH2:FUN 8 Verify Channel 2 function and press OK PASSW 9 Verify password and press OK SIL.OK 10 Verify SIL and press OK * Open is shown briefly in the display. 8 Version No. V5R0

53 If password is set 9203 Solenoid / Alarm Driver Safety Manual Action Display shows 1 Press OK PASSW 2 Enter password and press OK ADV.SET 3 Set (ADV.SET) to Yes and press OK DISP SETUP 4 Step down to (SIL SETUP) and press OK EN.SIL 5 Set (EN SIL) to YES and press OK (At this time the device starts operating in SIL mode with the entered configuration parameters!) 6 Press OK to confirme verification of the OPEN-LOCK in the display Verify OPEN briefly LOCK* CH1.FUN 7 Verify Channel 1 function and press OK CH2:FUN 8 Verify Channel 2 function and press OK PASSW 9 Verify password and press OK SIL.OK 10 Verify SIL and press OK * Open is shown briefly in the display 14.3 Functional test The user is responsible for making a functional test after verification of safety parameters. The procedure for periodic proof test described in section 10 shall be used. 15. Fault reaction and restart condition When the 9203 detects a fault the output will go to Safe State, in which the safety output will go to de-energised. For device faults there are 2 ways of bringing the device out of Safe State. 1. Power cycle the device. 2. Bring the device out of SIL mode (choose NO in the menu point EN.SIL ), and set it back to SIL mode again (choose YES in the menu point EN.SIL and verify the configuration). Version No. V5R0 9

54 Safety Manual 16 User interface [[01] [02] [06] [07] [09] [10] [11] [12] [13] [14] [15] [16] [17] [20] [21] [22] 9203 Solenoid / Alarm Driver 16.1 Scrolling help texts in display line 3 Set correct password Enter advanced setup? Enter language setup Enter password setup Enter display setup Enter SIL setup Select direct channel function Select inverted channel function Adjust LCD contrast Adjust LCD backlight Write a 5-character channel tag Show output state in display Show output load in display Show tag in display Alternate information shown in display Configuration SIL status (Open / Locked) Enable SIL configuration lock Enable password protection? Set new password Select language No communication - check connections EEprom error - check configuration Hardware error 10 Version No. V5R0

55 9203 Solenoid / Alarm Driver Safety Manual Routing diagram If no key is activated for 1 minute, the display will return to the default state 1.0 without saving configuration changes. 1 Increase value / choose next parameter 2 Decrease value / choose previous parameter 3 Accept the chosen value and proceed to the next menu Hold 3 Back to previous menu / return to menu 1.0 without saving Power up Directly to [EN.SIL] if SIL-lock is enabled ON OFF NO PASSW. Txt NO YES ADV.SET Txt 2 DIR INV 3 DIR CH1.FUN Txt 7 3 DIR INV DIR CH2.FUN Txt 7 3 To default state 1.0 YES 3 ADV.SET Txt 2 Continued on the page Routing diagram ADV.SET 1.0 = Default state Linie 1 shows status for channel 1 and channel 2. Linie 2 shows output status for channel 1, output current or tag no. Linie 3 shows output status for channel 2, output current or tag no. Line 4 indicates whether the module is SIL-locked. 1.1 = Only if password-protected. 1.2 If password has been set. Line 1 symbols: = OK. Flashing = error. Line 2 and 3 symbols: ON = channel 1 ON OFF channel 2 OFF. Line 4 symbols: Static dot = SIL-locked. Flashing dot = Not SIL-locked. = output is active. Version No. V5R0 11

56 Safety Manual 9203 Solenoid / Alarm Driver 16.3 Routing diagram - Advanced settings (ADV.SET) DISP, PASS, LANG, SIL DISP SETUP Txt CONTRA Txt LIGHT Txt A TAG1 VALVE 5 Txt A TAG2 VALVE 6 Txt 11 ALT LOAD TAG D.OUT 3 LOAD 3 DISP Txt 12 PASS SETUP Txt 06 YES NO 3 YES 3 EN.PASS Txt NEW.PAS Txt 16 NO LANG SETUP Txt 06 DE, DK, ES, FR, IT, SE, UK 3 UK LANGUA Txt 17 3 To default state 1.0 SIL SETUP Txt 06 YES NO 3 YES EN.SIL Txt NEW.PAS Txt 16 NO LOCK OPEN 3 LOCK CONFIG Txt 13 Verify SIL configuration SIL.OK 12 Version No. V5R0

57 17 Connections diagram 9203 Solenoid / Alarm Driver Safety Manual Power rail connections Supply and status relay Error NC = No connection Gnd. NC +24 V NC Gnd. +24 V N.C. Inputs xxx: Channel 1 Switch (6 V)* + NPN (6 V)* PNP (6 V)* PNP input D external R Channel 2 Switch (6 V)* + NPN (6 V)* PNP (6 V)* NPN input D external R * 6 V at open state Version No. V5R0 13

58 Safety Manual 9203 Solenoid / Alarm Driver Inputs xxx1: Channel 1 Switch PNP PNP with pull-down Active input R Channel 2 Switch with pull-down R PNP PNP with pull-down R Active input Inputs xxx2: Channel 1 Switch with NPN pull-up with pull-up NPN Active input R R Channel 2 Switch with pull-down NPN with pull-up R NPN Active input 14 Version No. V5R0

59 Channel Solenoid / Alarm Driver Safety Manual Outputs xxxx: Solenoid, ON / OFF Acoustic alarm LED Channel 2 Solenoid, ON / OFF Acoustic alarm LED Version No. V5R0 15

60 Displays Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces for analogue and digital signals as well as HART signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 & 2 and for some devices in zone 20, 21 & 22. Isolation Galvanic isolators for analogue and digital signals as well as HART signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling of output signals. Temperature A wide selection of transmitters for DIN form B mounting and DIN rail devices with analogue and digital bus communication ranging from applicationspecific to universal transmitters. Universal PC or front programmable devices with universal options for input, output and supply. This range offers a number of advanced features such as process calibration, linearisation and auto-diagnosis.

61 Head office Denmark PR electronics A/S Lerbakken 10 tel DK-8410 Rønde fax

Produktmanual 9203 Ventil - / alarmdriver

Produktmanual 9203 Ventil - / alarmdriver Produktmanual 9203 Ventil - / alarmdriver PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9203V107-DK Produktversion: 9203-003 6 produktområder

Læs mere

Ventil- / alarmdriver. Nr. 9203V105-DK Produktversion: 9203-003

Ventil- / alarmdriver. Nr. 9203V105-DK Produktversion: 9203-003 9203 Ventil- / alarmdriver Nr. 9203V105-DK Produktversion: 9203-003 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Switchmode spændingsforsyning. Nr. 2220V102-DK Fra serienr. 970003001

Switchmode spændingsforsyning. Nr. 2220V102-DK Fra serienr. 970003001 2220 Switchmode spændingsforsyning Nr. 2220V102-DK Fra serienr. 970003001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Ventil- / alarmdriver. Nr. 9203V102-DK Produktversion: 9203-002 SIGNALS THE BEST

Ventil- / alarmdriver. Nr. 9203V102-DK Produktversion: 9203-002 SIGNALS THE BEST 9203 Ventil- / alarmdriver Nr. 9203V102-DK Produktversion: 9203-002 SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel

Læs mere

Ventil- / alarmdriver. Nr. 9203V103-DK Produktversion:

Ventil- / alarmdriver. Nr. 9203V103-DK Produktversion: 9203 Ventil- / alarmdriver Nr. 9203V103-DK Produktversion: 9203-002 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Målestrømsforsynet isolator. Nr. 6185V100-DK Fra serienr

Målestrømsforsynet isolator. Nr. 6185V100-DK Fra serienr 6185 Målestrømsforsynet isolator Nr. 6185V100-DK Fra serienr. 020271001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Transformator. Nr. 2240V101-DK Fra serienr

Transformator. Nr. 2240V101-DK Fra serienr 2240 Transformator Nr. 2240V101-DK Fra serienr. 970279001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Power Control Unit. Nr. 9410V101-DK Produktversion:

Power Control Unit. Nr. 9410V101-DK Produktversion: 9410 Power Control Unit Nr. 9410V101-DK Produktversion: 9410-001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Pulse isolator. Nr. 9202V104-DK Produktversion:

Pulse isolator. Nr. 9202V104-DK Produktversion: 9202 Pulse isolator Nr. 9202V104-DK Produktversion: 9202-003 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Dobbelt switchmode spændingsforsyning. Nr. 2223V101-DK Fra serienr

Dobbelt switchmode spændingsforsyning. Nr. 2223V101-DK Fra serienr 2223 Dobbelt switchmode spændingsforsyning Nr. 2223V101-DK Fra serienr. 970296001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel

Læs mere

Pulse isolator SIGNALS THE BEST. Nr. 9202V103-DK Produktversion: PENDING

Pulse isolator SIGNALS THE BEST. Nr. 9202V103-DK Produktversion: PENDING 9202 Pulse isolator Nr. 9202V103-DK Produktversion: 9202-003 PENDING SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel

Læs mere

S I G N A L S T H E B E S T

S I G N A L S T H E B E S T 9 2 0 2 P u l s e i s o l a t o r N r. 9 2 0 2 V 1 0 2 - D K P r o d u k t v e r s i o n : 9 2 0 2-0 0 2 PENDING PENDING S I G N A L S T H E B E S T DK UK FR DE PR electronics A/S tilbyder et bredt program

Læs mere

2-tråds programmerbar transmitter. Nr. 6333V103-DK Fra serienr

2-tråds programmerbar transmitter. Nr. 6333V103-DK Fra serienr 6333 2-tråds programmerbar transmitter Nr. 6333V103-DK Fra serienr. 080629052 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Produktmanual 9202 Pulse isolator

Produktmanual 9202 Pulse isolator Produktmanual 9202 Pulse isolator PERFORMANCE MADE SMARTER CCOE TEMPERATUR EXBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9202V106DK Produktversion: 9202003 6 produktområder

Læs mere

Produktmanual 9106B HART-transparent repeater

Produktmanual 9106B HART-transparent repeater Produktmanual 9106B HARTtransparent repeater PERFORMANCE MADE SMARTER CCOE TEMPERATUR EXBARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9106V105DK Produktversion: 9106002 6 produktområder

Læs mere

Loop Link USB-kommunikations- Interface No. 5909V102-DK From ser. no

Loop Link USB-kommunikations- Interface No. 5909V102-DK From ser. no 5909 Loop Link USB-kommunikations- Interface No. 5909V102-DK From ser. no. 059999999 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel

Læs mere

Produktmanual 9410 Power control unit

Produktmanual 9410 Power control unit Produktmanual 9410 Power control unit PERFORMANCE MADE SMARTER TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 9410V103-DK Produktversion: 9410-001 6 produktområder

Læs mere

HART -transparent driver. Nr. 5107V103-DK Fra serienr

HART -transparent driver. Nr. 5107V103-DK Fra serienr 5107 HART -transparent driver Nr. 5107V103-DK Fra serienr. 010454001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Spændingsforsyning. Nr. 9420V100-DK Produktversion: 9420-102 FY26

Spændingsforsyning. Nr. 9420V100-DK Produktversion: 9420-102 FY26 9420 Spændingsforsyning Nr. 9420V100-DK Produktversion: 9420-102 FY26 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Temperatur- / ma-konverter. No. 9113V105-DK Produktversion: 9113-004

Temperatur- / ma-konverter. No. 9113V105-DK Produktversion: 9113-004 911 Temperatur- / ma-konverter No. 911V105-DK Produktversion: 911-004 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

6 m m i s o l a t o r- o g k o n v e r t e r s e r i e. M o d e l n r / / / / S I G N A L S T H E B E S T

6 m m i s o l a t o r- o g k o n v e r t e r s e r i e. M o d e l n r / / / / S I G N A L S T H E B E S T 3 1 0 0 6 m m i s o l a t o r- o g k o n v e r t e r s e r i e M o d e l n r. 3 1 0 3 / 3 1 0 4 / 3 1 0 5 / 3 1 0 8 / 3 1 0 9 N r. 3 1 0 0 V 1 0 6 - D K S I G N A L S T H E B E S T DK UK FR DE PR electronics

Læs mere

Isolationsforstærker. Nr. 2284V104-DK Fra serienr

Isolationsforstærker. Nr. 2284V104-DK Fra serienr 2284 Isolationsforstærker Nr. 2284V104-DK Fra serienr. 970388001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Produktmanual 9113 Temperatur- / ma-konverter

Produktmanual 9113 Temperatur- / ma-konverter Produktmanual 911 Temperatur- / ma-konverter PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 911V107-DK Produktversion: 911-004 6 produktområder

Læs mere

WIO200A INSTALLATIONS MANUAL Rev Dato:

WIO200A INSTALLATIONS MANUAL Rev Dato: WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of

Læs mere

2-tråds programmerbar transmitter. Nr. 6331V105-DK Fra serienr

2-tråds programmerbar transmitter. Nr. 6331V105-DK Fra serienr 6331 2-tråds programmerbar transmitter Nr. 6331V105-DK Fra serienr. 079224041 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

UNISONIC TECHNOLOGIES CO.,

UNISONIC TECHNOLOGIES CO., UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output

Læs mere

2-tråds programmerbar transmitter. Nr. 5333V110-DK Fra serienr. 080629052 SIGNALS THE BEST

2-tråds programmerbar transmitter. Nr. 5333V110-DK Fra serienr. 080629052 SIGNALS THE BEST 5333 2-tråds programmerbar transmitter Nr. 5333V110-DK Fra serienr. 080629052 SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til

Læs mere

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med

Læs mere

2-tråds programmerbar transmitter. Nr. 6334V105-DK Fra serienr

2-tråds programmerbar transmitter. Nr. 6334V105-DK Fra serienr 6334 2tråds programmerbar transmitter Nr. 6334V105DK Fra serienr. 099256000 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Indholdsfortegnelse. 9113 - Product Version 9113-003 1

Indholdsfortegnelse. 9113 - Product Version 9113-003 1 9 1 1 T e m p e r a t u r - / m A - k o n v e r t e r N o. 9 1 1 V 1 0 - D K P r o d u c t v e r s i o n : 9 1 1-0 0 PENDING PENDING S I G N A L S T H E B E S T DK UK FR DE PR electronics A/S tilbyder

Læs mere

MultiProgrammer Manual

MultiProgrammer Manual MultiProgrammer Manual MultiProgrammeren bruges til at læse og skrive værdier til ModBus register i LS Controls frekvensomformer E 1045. Dansk Version side 2 til 4 The MultiProgrammer is used for the writing

Læs mere

WIO200A Water in oil sensor

WIO200A Water in oil sensor WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic

Læs mere

Plug Connectors for Food & Beverage

Plug Connectors for Food & Beverage Plug Connectors for Food & Beverage Made with stainless steel Food grade quality High protection degree MeeTS DEMANDING HYGIENIC STANDARDS The food and beverage industry needs an extremely clean environment

Læs mere

Produktmanual 5202 Impulsisolator

Produktmanual 5202 Impulsisolator Produktmanual 50 Impulsisolator PERFORMANCE MADE SMARTER TEMPERATUR I.S. INTERFACES KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAY Nr. 50V100-DK Fra serienr.: 030481661 6 produktområder der

Læs mere

Digital positioner type RE 3446

Digital positioner type RE 3446 Installations- og driftsvejledning IN145 Digital positioner type Indholdsfortegnelse: Side 1 Generel information 2 2 Montering og tilslutning 2 3 Idriftsættelse 3 4 Drifts funktioner 6 5 Funktions beskrivelser

Læs mere

Programmerbar f/i - f/f konverter. Nr. 5225V101-DK Fra serienr

Programmerbar f/i - f/f konverter. Nr. 5225V101-DK Fra serienr 5225 Programmerbar f/i - f/f konverter Nr. 5225V101-DK Fra serienr. 970297001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Repeater / Power Supply. No. 5104V104-DK Fra serienr SIGNALS THE BEST

Repeater / Power Supply. No. 5104V104-DK Fra serienr SIGNALS THE BEST 5104 Repeater / Power Supply No. 5104V104DK Fra serienr. 030250001 SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel

Læs mere

Intrinsically Safe Tablet PC

Intrinsically Safe Tablet PC Intrinsically Safe Tablet PC Pad-Ex 01 HR DZ2 User s Manual Zone 2 / DIV 2 EN-1 1 We CAUTION FOR ADAPTER BATTERY SAFETY Relevant information for Ex-protection

Læs mere

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL! DANSK INSTALLATIONSVEJLEDNING VLMT500 Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse. Kontroller at

Læs mere

WI180C-PB. Online-datablad

WI180C-PB. Online-datablad Online-datablad A B C D E F H I J K L M N O P Q R S T Oversigt over tekniske data Tekniske data Tilbehørsfamilie Henvisning Kapslingsklasse Dimensioner (B x H x L) Beskrivelse Klassifikationer Bestillingsoplysninger

Læs mere

2-tråds programmerbar transmitter. Nr. 5331V114-DK Fra serienr CCOE

2-tråds programmerbar transmitter. Nr. 5331V114-DK Fra serienr CCOE 5331 2-tråds programmerbar transmitter Nr. 5331V114-DK Fra serienr. 141365001 CCOE Revision Notes The following list provides notes concerning revisions of this document. Rev. ID Date Notes 113 13/45 IECEx

Læs mere

Produktmanual tråds programmerbar transmitter

Produktmanual tråds programmerbar transmitter Produktmanual 5333 2-tråds programmerbar transmitter PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS No. 5333V114-DK Fra serienr. 132094001-132094630

Læs mere

Vejledning for TKE 01 Ver 4.01

Vejledning for TKE 01 Ver 4.01 Vejledning for TKE 01 Ver 4.01 TKE-01 er lavet specielt til at arbejde sammen med en Calyma ventilationunit med Lemmens DC-motorer. POWER ON SPJÆLD LUKKET FEJL TRYKFEJL VARME STYRING under 18 grader Temperatur

Læs mere

Delta Elektronik A/S - AKD

Delta Elektronik A/S - AKD Delta Elektronik A/S - AKD Hardware og type oversigt Grundlæggende oplysninger med forbindelser Opsætning af IP adresser på drev alle muligheder Gennemgang af WorkBench Up/Down load parametre filer Mest

Læs mere

Navn: DVG V 450EC/F400 varenr.: 95257

Navn: DVG V 450EC/F400 varenr.: 95257 DVG-V 450EC/F400 varenr. 95257 Document type: Product card Document date: 2012-11-08 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

MS-H280-Pro Magnetic Stirrer

MS-H280-Pro Magnetic Stirrer MS-H280-Pro Magnetic Stirrer www..com Copyright: No part of this manual may be reproduced or transmitted without prior written permission of. VERSION201407 CONTENTS Chapter 1: Working Principle... 3 1

Læs mere

Navn: DVG V 560EC/F400 varenr.: 95135

Navn: DVG V 560EC/F400 varenr.: 95135 DVG-V 560EC/F400 varenr. 95135 Document type: Product card Document date: 2012-11-08 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

Power Supply 24V 2.1A

Power Supply 24V 2.1A Power Supply 24V 2.1A Strømforsyning 24 V 2,1 A Power Supply 24V 2.1A Stromversorgung 24 V 2,1 A Teknisk brugervejledning Technical User Guide Technische Bedienungsanleitung 2015.04.21 604159 Technical

Læs mere

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax TM4 Central Station User Manual / brugervejledning K2070-EU STT Condigi A/S Niels Bohrs Vej 42, Stilling 8660 Skanderborg Denmark Tel. +45 87 93 50 00 Fax. +45 87 93 50 10 info@sttcondigi.com www.sttcondigi.com

Læs mere

Produktmanual tråds programmerbar transmitter

Produktmanual tråds programmerbar transmitter Produktmanual 5331 2-tråds programmerbar transmitter PERFORMANCE MADE SMARTER CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS No. 5331V116-DK Fra serienr. 141365001

Læs mere

mv-transmitter Nr. 2261V101-DK Fra serienr

mv-transmitter Nr. 2261V101-DK Fra serienr 2261 mv-transmitter Nr. 2261V101-DK Fra serienr. 970106001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Date of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO

Date of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO JENSEN CLASSIC FOLDER JENSEN MAX STACKER MANUAL MANUAL Date of issue 2005.11.04 Fremstillingsdato Machine no. 760790, 492147 Maskinnr. Distributor / Forhandler Project Manufacturer / Fabrikant JENSEN USA

Læs mere

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss Brugervejledning (side 2-6) Userguide (page 7-11) Bedienungsanleitung 1 - Hvordan forbinder du din E-PAD hængelås med din

Læs mere

frame bracket Ford & Dodge

frame bracket Ford & Dodge , Rev 3 02/19 frame bracket 8552005 Ford & Dodge ITEM PART # QTY DESCRIPTION 1 00083 8 NUT,.50NC HEX 2 00084 8 WASHER,.50 LOCK 3 14189-76 2 FRAME BRACKET 4 14194-76 1 411AL FRAME BRACKET PASSENGER SIDE

Læs mere

SPIDER Quick guide. DATO: August 2017 FORHANDLER: WASYS A/S. Langebjergvænget Roskilde

SPIDER Quick guide. DATO: August 2017 FORHANDLER: WASYS A/S. Langebjergvænget Roskilde SPIDER Quick guide DATO: August 2017 FORHANDLER: WASYS A/S Langebjergvænget 18 4000 Roskilde +45 7221 7979 Indhold Om SPIDER... 3 Funktioner ved SPIDER... 3 Spændingsforsyning... 3 Installation og fysiske

Læs mere

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet.

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet. ATEX direktivet Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet.dk tlf: 7220 2693 Vedligeholdelse af Certifikater / tekniske dossier / overensstemmelseserklæringen.

Læs mere

Produktmanual 3100-serien 6 mm isolator- og konverterserie

Produktmanual 3100-serien 6 mm isolator- og konverterserie Produktmanual 3100-serien 6 mm isolator- og konverterserie PERFORMANCE MADE SMARTER ZONE 2 Zone 2 ZONE 2 / DIV 2 CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS

Læs mere

CO2 Control Box E-Cab-980

CO2 Control Box E-Cab-980 CO2 Control Box E-Cab-980 CO2 Control Box E-Cab-980 er beregnet til detektering og alarmereing ved utætheder i CO2 køleanlæg i køle- og fryserum. CO2 Control Box E-Cab-980 er designet til at fungere sammen

Læs mere

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. 67436 05/15 (OSH) 2015 OJ Electronics A/S

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. 67436 05/15 (OSH) 2015 OJ Electronics A/S INSTRUKTION 67436 05/15 (OSH) 2015 OJ Electronics A/S OJ-DV Hterm OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS GENERELT OJ-DV Hterm er en håndbetjeningsenhed, som anvendes til indstilling

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK). DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

WT-1675B-8 GSM Alert and Monitoring System 9 inputs, 1 relay

WT-1675B-8 GSM Alert and Monitoring System 9 inputs, 1 relay VERSION: 1.2 UPDATED: AUG 2013 WT-1675B-8 GSM Alert and Monitoring System 9 inputs, 1 relay BRUGER MANUAL Feb 2015 Ver. 1 1 INTRODUKTION WT-1675B-8 GSM Er en smart lille GSM kontroller med 8 digitale indgange

Læs mere

OVERVÅGNINGSSYSTEM FICO-64» MONTAGEANVISNING

OVERVÅGNINGSSYSTEM FICO-64» MONTAGEANVISNING FIRE SAFETY AIR MANAGEMENT OVERVÅGNINGSSYSTEM» MONTAGEANVISNING 2 1 TILSLUTNING 1.5 RØGDETEKTOR 1 eller 2 røgdetektorer (se DIP indstillinger) kan vælges. 1.1 GENERELT Styreenheden SOC8-S2 indeholder elektroniske

Læs mere

Produktmanual 3185 Loop-forsynet isolator

Produktmanual 3185 Loop-forsynet isolator Produktmanual 3185 Loop-forsynet isolator PERFORMANCE MADE SMARTER ZONE 2 Zone 2 ZONE 2 / DIV 2 CCOE TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 3185V101-DK

Læs mere

Ex-barrierer. til procesindustrien. display. ex-interface. isolation. temperatur. universel

Ex-barrierer. til procesindustrien. display. ex-interface. isolation. temperatur. universel Ex-barrierer til procesindustrien display ex-interface isolation temperatur universel 2 Optimal Ex-signalbehandling PR electronics er en af verdens førende leverandører af moduler til industriel Ex-signalbehandling

Læs mere

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS). Bilag 8. TDC technical requirements for approval of splitters and inline s intended for shared access (ADSL or VDSL over POTS). Dette bilag udgør bilag 8 til det mellem parterne tiltrådte Produkttillæg

Læs mere

Programmerbar f/i - I/f konverter. Nr. 5223B103-DK Fra serienr.:

Programmerbar f/i - I/f konverter. Nr. 5223B103-DK Fra serienr.: 5223 Programmerbar f/i - I/f konverter Nr. 5223B103-DK Fra serienr.: 040029001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Universalkonverter. Nr. 9116V103-DK Produktversion: 9116-003 SIGNALS THE BEST

Universalkonverter. Nr. 9116V103-DK Produktversion: 9116-003 SIGNALS THE BEST 9116 Universalkonverter Nr. 9116V10-DK Produktversion: 9116-00 SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation.

Læs mere

Hi-Res Audio/DNC Headset MDR-NC750

Hi-Res Audio/DNC Headset MDR-NC750 Brugervejledning Hi-Res Audio/DNC Headset MDR-NC750 Indholdsfortegnelse Introduktion... 3 Introduktion...3 Oversigt... 3 De grundlæggende funktioner... 4 Sådan bærer du headsettet... 4 Tilslutning af dit

Læs mere

Lovkrav vs. udvikling af sundhedsapps

Lovkrav vs. udvikling af sundhedsapps Lovkrav vs. udvikling af sundhedsapps Health apps give patients better control User Data Social media Pharma Products User behaviour Relatives www Self monitoring (app) data extract Healthcare specialists

Læs mere

2x50 ETHERNET MODUL. RS485 slave med Ethernet-IP. Gælder for: Program nr.: AUXSLAVE v1 Dokument nr.: 0422md2x50-2v1 Dato:

2x50 ETHERNET MODUL. RS485 slave med Ethernet-IP. Gælder for: Program nr.: AUXSLAVE v1 Dokument nr.: 0422md2x50-2v1 Dato: Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 2x50 ETHERNET MODUL RS485 slave med Ethernet-IP Gælder for: Program nr.: AUXSLAVE.140422.2v1 Dokument

Læs mere

Ventilstyring. Nr. 2224V103-DK Fra serienr

Ventilstyring. Nr. 2224V103-DK Fra serienr 2224 Ventilstyring Nr. 2224V103-DK Fra serienr. 060223001 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet

Læs mere

Online-datablad. T4000-1RBA01 T4000 Standard PRODUKTPORTEFØLJE

Online-datablad. T4000-1RBA01 T4000 Standard PRODUKTPORTEFØLJE Online-datablad T4000-1RBA01 T4000 Standard A B C D E F H I J K L M N O P Q R S T Oversigt over tekniske data Egenskaber Systemdel Sikkerhedstekniske parametre Bestillingsoplysninger Type Andre instrumentudførelser

Læs mere

PROFIBUS PA / FOUNDATION Fieldbus transmitter. Nr. 6350V103-DK Fra serienr. 090449300

PROFIBUS PA / FOUNDATION Fieldbus transmitter. Nr. 6350V103-DK Fra serienr. 090449300 6350 PROFIBUS PA / FOUNDATION Fieldbus transmitter Nr. 6350V103DK Fra serienr. 090449300 DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel

Læs mere

Side 1. Page 21. Page 41. Seite 61. Pulse isolator SIGNALS THE BEST PENDING. No. 9202V102-IN (0927) Product version:

Side 1. Page 21. Page 41. Seite 61. Pulse isolator SIGNALS THE BEST PENDING. No. 9202V102-IN (0927) Product version: DK UK FR DE Side 1 Page 21 Page 41 Seite 61 9202 Pulse isolator No. 9202V102-IN (0927) Product version: 9202-002 PENDING SIGNALS THE BEST DK UK FR DE PR electronics A/S tilbyder et bredt program af analoge

Læs mere

Produktmanual tråds programmerbar transmitter

Produktmanual tråds programmerbar transmitter PERFORMANCE MADE SMARTER Produktmanual 6333 2-tråds programmerbar transmitter TEMPERATUR Ex-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS Nr. 6333V104-DK Fra serienr.: 1517871082

Læs mere

QUICK START Updated:

QUICK START Updated: QUICK START Updated: 24.08.2018 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get started

Læs mere

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color

Læs mere

Help / Hjælp

Help / Hjælp Home page Lisa & Petur www.lisapetur.dk Help / Hjælp Help / Hjælp General The purpose of our Homepage is to allow external access to pictures and videos taken/made by the Gunnarsson family. The Association

Læs mere

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications RAVE The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications Product Presentation RAVE radar motion sensor In addition to the RaDec and RMS product families, the new RAVE radar

Læs mere

Technical Specifications

Technical Specifications Technical Specifications Pressure measuring range (bar) 0.1... 0.5, (1) > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar > 200 bar Accuracy, (5), (± % FS)

Læs mere

GSM REMOTE CONTROL AND MONITORING SYSTEM Model: GSM-220

GSM REMOTE CONTROL AND MONITORING SYSTEM Model: GSM-220 GSM REMOTE CONTROL AND MONITORING SYSTEM Model: GSM-220 For nyeste manual www.termalou.com Indholdsfortegnelse Intorduktion....... 4 Pakkens indhold......4 Enhedens design....5 Installations Diagram...5

Læs mere

DX-610/DX-626 6CH.DMX DIMMER PACK

DX-610/DX-626 6CH.DMX DIMMER PACK DX-610/DX-626 6CH.DMX DIMMER PACK User Manual Lite Puter Enterprise Co., Ltd. Website: E-mail sales@liteputer.com.tw 1 DX-610/626 [EUM-I] INDEX SAFETY INTRODUCTION...2 The Load Power...2 Working Environment...2

Læs mere

Innovation for system integration

Innovation for system integration Innovation for system integration PERFORMANCE MADE SMARTER PR backplane En brugervenlig og pålidelig monteringsløsning mellem DCS/PLC/SIS systemet og Ex barrierer /signalisolatorer TEMPERATUR EX BARRIERER

Læs mere

TDC 4 Indoor voltage transformers

TDC 4 Indoor voltage transformers Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,

Læs mere

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001 Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001 Ls venligst denne instruktions manual igennem inden brug af produktet Thank you for purchasing our product. This smart unit is not

Læs mere

2-tråds niveautransmitter. Nr. 5343V104-DK Fra serienr

2-tråds niveautransmitter. Nr. 5343V104-DK Fra serienr 5343 2-tråds niveautransmitter Nr. 5343V104-DK Fra serienr. 141298001 Revision Notes The following list provides notes concerning revisions of this document. Rev. ID Date Notes 104 14/14 IECEx, FM and

Læs mere

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret 12-10-2011 /JLK

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret 12-10-2011 /JLK Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings QVEX Clima Revideret 12-10-2011 /JLK mit: JLK CC: Dato: 12-10-2011 Indhoidsfortegnelse I Table

Læs mere

Programmable pressure transmitters PTM

Programmable pressure transmitters PTM Programmable pressure transmitters PTM Version: 07.01.2016 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure

Læs mere

CKE-21 Software version 21.01B

CKE-21 Software version 21.01B CKE-21 Software version 21.01B CKE-21 er en Calyma Kontrol Enhed der er udviklet til energiøkonomisk drift af DC motorer i Calyma ventilationsunit, og samtidig er der kontrol over en blandefunktion som

Læs mere

QUICK START Updated: 18. Febr. 2014

QUICK START Updated: 18. Febr. 2014 QUICK START Updated: 18. Febr. 2014 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get

Læs mere

Brugervejledning. MHL to HDMI Adapter IM750

Brugervejledning. MHL to HDMI Adapter IM750 Brugervejledning MHL to HDMI Adapter IM750 Indholdsfortegnelse Indledning...3 Oversigt over MHL to HDMI Adapter...3 Kom godt i gang...4 Smart Connect...4 Opgradering af Smart Connect...4 Brug af MHL to

Læs mere

Xperia TX TV Dock DK22 Xperia T TV Dock DK23

Xperia TX TV Dock DK22 Xperia T TV Dock DK23 Brugervejledning Xperia TX TV Dock DK22 Xperia T TV Dock DK23 Indholdsfortegnelse Indledning...3 Oversigt over TV Dock...3 Kom godt i gang...4 Smart Connect...4 Opgradering af Smart Connect...4 Brug af

Læs mere

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 DK: Davo-Meg 1002: 87 98 301 819 Davo-Meg 1002B: 87 98 301 822 EAN: Davo-Meg 1002: 5703534100059 Davo-Meg 1002B: 5703534100202 Indhold

Læs mere

Brugervejledning. Xperia P TV Dock DK21

Brugervejledning. Xperia P TV Dock DK21 Brugervejledning Xperia P TV Dock DK21 Indholdsfortegnelse Indledning...3 Bagside oversigt over TV Dock...3 Kom godt i gang...4 Håndtering af LiveWare...4 Opgradering af Håndtering af LiveWare...4 Brug

Læs mere

Produktmanual tråds niveautransmitter

Produktmanual tråds niveautransmitter Produktmanual 5343 2-tråds niveautransmitter PERFORMANCE MADE SMARTER TEMPERATUR EX-BARRIERER KOMMUNIKATIONSINTERFACES MULTIFUNKTIONEL ISOLATION DISPLAYS No. 5343V107-DK Fra serienr. 141298001 6 produktområder

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

Produktmanual 3117 Bipolar isolator konverter

Produktmanual 3117 Bipolar isolator konverter Produktmanual 3117 Bipolar isolator konverter PERFORMANCE MADE SMARTER ZE 2 Zone 2 ZE 2 / DIV 2 CCOE TEMPERATUR I.S. INTERFACES KOMMUNIKATISINTERFACES MULTIFUNKTIEL ISOLATI DISPLAY Nr. 3117V01-DK Fra serienr.:

Læs mere

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System CERTIFICATE Panasonic Fire & Security Europe AB Jungmansgatan 12 SE 211 19 Malmö Sweden Certifikat nr. Certificate no. 232.258 har på baggrund af vurderede systemegenskaber baseret på systemprøvningsrapport(er)

Læs mere

QUICKVEJLEDNING til Piccolo Light

QUICKVEJLEDNING til Piccolo Light QUICKVEJLEDNING til Piccolo Light Montering 1. Piccolo Light kan installeres uden brug af kommunikation via GSM, men installeres et SIM-kort i enheden, vil man bl.a. kunne få alarmer som sms og email.

Læs mere

Sikkerhed & Revision 2013

Sikkerhed & Revision 2013 Sikkerhed & Revision 2013 Samarbejde mellem intern revisor og ekstern revisor - og ISA 610 v/ Dorthe Tolborg Regional Chief Auditor, Codan Group og formand for IIA DK RSA REPRESENTATION WORLD WIDE 300

Læs mere