PowerMax. For sikre, integrerede og interaktive hjem - Alarmgruppen har det hele. Plug and Protect - problemfri installation
|
|
|
- Bjørn Laustsen
- 10 år siden
- Visninger:
Transkript
1 PowerMax,, For sikre, integrerede og interaktive hjem - Alarmgruppen har det hele. Plug and Protect - problemfri installation Kameraforbindelse giver her og nu indsigt Tilgængelig hvor som helst gennem Internet, mobil eller fastnettelefon Afprøvet pålidelighed GSM kommunikation / IP kommunikation
2 , Vi forestiller os en verden, hvor alle mennesker nyder følelsen af sikkerhed, personligt og for deres ejendom, såvel hjemme som på arbejde. Og nyder friheden til at kunne vælge sin egen livsstil. Med hundrede tusinder af trådløse installationer over hele verden, er Visonic i front med trådløs Sikkerhed og styring i hjemmet. Lige siden starten i 1972, har Visonic sat standarden for innovative trådløse systemløsninger. Visonic s produkter har vundet industriens anerkendelse, fordi de ganske enkelt fungerer. Ingen tomme løfter, men blot pålidelige, driftsikre og holdbare produkter, der gør deres job. Visonic har forpligtet sig til at udvikle banebrydende trådløse løsninger, der forbedrer livskvaliteten. Dette demonstreres ikke mindst gennem en meget høj investering i udviklingsprojekter, der genererer avancerede patenterede teknologier og pålidelige, højt ydende systemer, der hver gang udfordrer branchen. Visonic's trådløse systemer er: Effektive tid og omkostninger ved installation er væsentligt reduceret. Fleksible systemerne opgraderes og udvides nemt, når behovene ændres, eller nye komponenter bliver tilgængelige. Æstetiske enkel installation der ikke ses, i et nutidigt design der falder ubemærket ind i hjemmets dekoration. Pålidelige branchens største følsomhed og nøjagtighed ved detektering, samt immunitet over for falske alarmer. Dette parret med et hurtigt og forstående, verdensomspændende netværk af kundesupport. Visonic s trådløse løsninger leverer den ultimative frihed: Friheden til at kunne se med et kamera; Friheden til at vælge tid og sted med absolut tilgængelighed og kontrol; friheden til at kunne slappe af; og den vigtigste frihed af alle friheden til at tage sig af det, der er virkelig vigtigt i livet. PowerMax+ 2,
3 , Absolut Frihed. Vi præsenterer PowerMax +. Vore dages familier ønsker mere end blot en simpel tyverialarm de ønsker at systemet kan meddele sig til dem i tilfælde af tyveri, brand og vandskade så vel som ved nødkald fra syge eller truede familiemedlemmer hvor som helst de er, hjemme eller ude. Men dette er kun begyndelsen. De ønsker kameraforbindelse til overvågning af fordøren, og børnenes værelse. De ønsker at kunne tænde og slukke for lys og elektriske apparater via telefonen. Nogle ønsker endda at have kontrol over deres hjem via Internet og SMS besked. Visonic s PowerMax + kan levere alt dette, og mere! Frihed fra kompliceret installation - Plug and Protect - Problemfri installation. PowerMax + trådløst system er klar til opsætning direkte fra indpakningen. Uden besværlig kabeloplægning, selv til den trådløse sirene, kan installationen færdiggøres på mindre end et par timer. Med Plug and Protect. Intuitiv programmering, understøttet af talte instruktioner, giver en nem detektor og systemopsætning. For dine kunder er installationen derfor en hurtig og smertefri operation. Så hurtig, at det ikke vil forstyrre deres dagligdag, og samtidig helt uden skader. Vægge og maling lades helt uberørt. Frihed til at se med kameraforbindelse. Endelig kan brugeren nu se, hvad der sker i hans hjem. Miniature kameraer på strategiske placeringer kan tilgås via en sikker Internet forbindelse. Forældre kan følge med, når børnene kommer hjem til fordøren og låser sig ind. Familiemedlemmer kan se, om nogen forgriber sig på deres ejendom og værdier. Og vigtigst ved reaktion på en hændelse kan denne observeres, og udvalgte billeder kan gemmes for senere verificering. 3, PowerMax+
4 , Frihed til at kunne slappe af branchens største følsomhed og nøjagtighed ved detektering, og bedste immunitet over for falske alarmer. PowerMax + leverer det højest niveau af avanceret trådløs sikkerhed, med den indbyggede pålidelighed der er grundlaget for Visonic's professionelle renommé. Sikrer ejendom med avancerede bevægelses sensorer, dør/vindue magnetkontakter og glasbrudsdetektorer. Patenterede intelligente PIR detektorer kan pålideligt skelne mellem et menneske og et dyr der vejer op til 38kg, så husdyr frit kan bevæge sig rundt i hjemmet. Patenteret True Motion Recognition teknologi leverer ekstrem høj immunitet over for falske alarmer og giver samtidig branchens bedste detektering. Avanceret støj detektering giver en sikker og hurtig rapportering af støjpåvirkning, i henhold til de mest strikse industristandarder. Forbedret! - Specielle zoner dedikerede til sikkerhedsrelaterede enheder, såsom gas, vand og røg sensorer. Sender en alarm ved detektering og igangsætter en prædefineret sekvens af reaktioner. Med en PowerMax + WebCommunicator, kan brugeren se strategiske områder såsom indgangspartiet, og dermed skelne mellem en falsk alarm og et rigtigt indbrud. PowerMax + er den perfekte sikkerhedsløsning for huse og lejligheder i alle størrelser. PowerMax+ 4,
5 , personal and property security PowerMax+ Freedom of movement Frihed til at være magelig - hjemmeautomation der er råd til. Ved at automatisere daglige opgaver i hjemmet, kan PowerMax + frigøre familien til at gøre de ting der virkelig betyder noget i livet, og samtidig spare penge på energibudgettet. PowerMax + kan, gennem anvendelsen af X-10 Power Line teknologi, styre lys og elektriske apparater i henhold til et tidsskema, ved bestemte hændelser eller ved et tryk på en knap. PowerMax + er også opgraderet til at inkludere 2-vejs X-10 styring af elektriske apparater, samt op og ned regulering af lyskilder, og er derigennem blevet et stærkt værktøj for egentlig energistyring. At spare på energien er blevet et kritisk emne verden over, med stigende energipriser og udtørringen af Verdens energiressourcer. Som mere end blot en behagelighed kan hjemmeautomation tilbyde smart styring af energiforbruget og familiens energibudget. Automatiserede rutiner kan forud fastlægges eller startes ved et tryk på en knap eller et opkald fra en telefon. Når et familiemedlem kommer hjem, kan et enkelt tryk på en knap være programmeret til samtidigt at åbne garageporten, tænde det udvendige lys, koble alarmsystemet fra og tænde Tv et - og kedlen til kaffevandet. Brugeren designer selv de automatiske rutiner, der passer hans individuelle livsstil. Ved nødsituationer såsom brand vil systemet ikke blot kunne sende en alarmmeddelelse, men også kunne aktivere ventilationssystemet og tænde lyset for at fjerne røg og oplyse flugtveje, så familien hjælpes til at finde vejen ud. PowerMax + anvender moderne teknologi til ejerens fordel, og gør livet mere behageligt, sjovere og billigere. PowerMax + styrer bl.a.: Lys Underholdningscentre Varme og kølesystemer Vandingssystemer Husholdningsapparater Design dit eget PowerMax + OEM / Mærke Dit Brand, vores produkt, ekspertise, pålidelighed og kvalitet Klar til levering som en OEM løsning, kan PowerMax + leveres med en vifte af tilpasninger efter ønske. Produktet kan modificeres med navn og Logo og et tilpasset udseende. 5, PowerMax+
6 , PowerMax + - Det ultimativt sikre, integrerede, Privat telefon SMS advisering Ejers Internetforbindelse PSTN GSM GSM Kontrolstation PSTN Lys Energistyring Elektriske apparater Styring i hjemmet Håndsender PowerMax+ 6, Respons Politi Ambulance Brand Trådløst tastatur
7 , interaktive hjem. Installatør Installatørs Internetforbindelse Fjernprogrammering Internet GSM PSTN System Admin. Server Sirene Kamera Web Communicator GSM GSM GSM GSM Adapter PSTN PSTN Hjem PowerMax+ Sikring i hjemmet Sikkerhed i hjemmet Nødhjælp Bevægelsesdetektor Røgdetektor Armbåndssender Glasbrudsdetektor Gasdetektor Smykkesender Magnetkontakt Vanddetektor 7, PowerMax+
8 , Frihed til at vælge tid og sted med absolut tilgængelighed og kontrol. PowerMax + tilbyder markedets mest alsidige vifte af kommunikationsmuligheder. Brugeren kan vælge at kommunikere med PowerMax + gennem en sikker, brugervenlig Web-applikation, , SMS besked, mobil eller almindelig telefon. Systemet tilbyder: Hændelsesadvicering til ejer og/eller til Kontrol Central Fjernstyring af lys, elektriske enheder og alarm. Frakoblingsrapport der informerer forældrene om et barns hjemkomst og frakobling af alarm Familiens beskedcentral der kan optage og afspille beskeder, lokalt eller fra telefon Fjernstyring af Håndfri 2-vejs tale kommunikation (Fuld Duplex: Samtidig tale/lytte) Frihed til at vælge tid og sted betyder også administration og service via telefon eller Web, med upload og downloadfunktion for nem og hurtig programmering. Frihed til at vælge - fleksibel, modulær og Helstøbt løsning. En PowerMax + løsning er modulær og giver derved mulighed for at vælge og tilføje enheder og detektorer på et hvilket som helst tidspunkt. Når behovet ændrer sig eller nye komponenter bliver tilgængelige, kan PowerMax + nemt udvides. Standarder og compatibilitet PowerMax + opfylder de gældende standarder i de fleste lande i verden. Bl.a: (CE/RTTE), EN &3, EN &3, EN60950, EN , EN , EN , BS-6799 Class VI og DD-243:2002. SIA false alarm prevention recommendation UL 985, UL 1023, UL1635, FCC part 15 and part 68, TBR-21 Kan leveres i følgende frekvenser - 315, , , , MHz PowerMax+ 8,
9 , PowerMax + Web Communicator Internetkommunikation og fjernstyring via grafisk brugerflade Med PowerMax + Web Communicator kan brugeren udnytte den fulde funktionalitet af systemet online, fra hvor som helst i verden. Ved at anvende en simpel web applikation og en sikker Internet forbindelse kan brugeren: Overvåge sit hjem, nemt og enkelt via sikker web forbindelse. Ændre systemets opsætning og konfiguration. Styre såvel alarmsystemet som lys, varme og elektriske enheder. Se levende billeder fra hjemmet, og således holde opsyn med børn, ældre svagelige eller husdyr. Verificere eller afvise en alarm (tyveri, brand etc.) og gemme udvalgte billeder. PowerMax + Web Communicator består af: En kommunikations adapter der håndterer Internet forbindelse og IP kommunikation. En Web server applikation der håndterer interface til såvel bruger som system administrator. Hver enhed kan understøtte op til fire miniature kameraer. PowerMax + GSM Adapter Sikrer backup af kommunikationen når telefonlinien er nede. En nødvendig løsning for enhver ejendom uden fast telefonforbindelse, såsom sommerhuse, opankrede både mm.. PowerMax + GSM Adapteren er også anbefalet som backup kommunikation i tilfælde af liniefejl eller systemsabotage. Anbefalet som backup I tilfælde af liniefejl. Hændelsesrapportering samt fjernstyring og kontrol via Short Message System (SMS). Fuld understøttelse af tovejs talekommunikation. Kan installeres skjult og væk fra alarmcentral og sikre pålidelig signalering i tilfælde af systemsabotage. 9, PowerMax+
10 , Visonic Trådløse PowerCode Enheder Trådløse Detektorer NEXT MCW Digitale bevægelsesdetektorer Smart nyt design der ikke er set før 12m, 90 multiple gardindækning Avanceret frekvensdomæne (DSP), digital signal processing Justeringsfri installation Forseglet optik 3 Volt standard Litiumbatteri for lang levetid MCT-550, Vanddetektor En vigtig komponent til skadesbegrænsning i hjemmet Detekterer vand i gulvhøjde, specielt velegnet til detektering af oversvømmelse i badeværelser og kældre. 3 Volt standard Litium batteri for lang levetid MCT-501, Glasbrudsdetektor Avanceret glasbrudsdetektor NEXT PIR MCW, generelt anvendelig digital trådløs PIR Akustisk sensor med 360 dækning NEXT K9-85 MCW, husdyrimmun (38kg) digital trådløs PIR Fremragende detektionsevne ved armerede, hærdede, laminerede og trådarmerede glastyper 3 Volt standard Litiumbatteri for lang levetid Discovery MCW bevægelsesdetektorer For de hårdeste og mest krævende betingelser Dækning For PIR & Quad: 15m, 90 multi-stråle dækning For K9-80: 12m, 90 multi-gardin dækning "True Motion Recognition" algoritme og programmerbar verifikation for alarmhændelse sikrer den ultimative pålidelighed Forseglet optik 3 Volt standard Litiumbatteri for lang levetid Discovery PIR MCW, Generelt anvendelig Discovery K9-80 MCW husdyrimmun (36kg) Discovery Quad MCW, Quaddetektor for ekstra stabilitet i krævende miljø MCT-425, Røgdetektor Avanceret fotoelektrisk røgdetektor BS godkendt, i overensstemmelse med EN standard Kraftig 85 db intern lydgiver Sabotagekontakt og test trykknap 9 Volts Alkaline eller Litiumbatteri Trådløs Sirene SPD-1000, Berøringsdetektor Udviklet til sikring af kunst: Billeder, skulpturer, udstillingsgenstande Diskret, miniature, fladt design for nem montage og ubemærket sikring. Overlegen berøringssensitivitet (bedre end 0.1mm) Valgbare alarmniveauer for berøringens styrke 3 Volt standard Litiumbatteri for lang levetid MCS-700, Ekstern trådløs sirene Overflødiggør lange kabeltræk fra central til sirene 98 db Piezo sirene og Strobe lys To-vejs kommunikation for lokal & fjern-diagnosticering Alarm, brand og til/frakoblings toner Stikprop strømforsyning med NiMH genopladeligt backupbatteri Tri-state tamperkontakt PowerMax+ 10,
11 , Bærbare håndsendere Dør/Vinduesendere MCT-234, Trådløs håndsender Designet til handy og nem til/frakobling af alarmcentralen Firefunktioners håndsender Kommunikerer med krypteret kodeteknologi (rullende krypteringskoder) Lavt batteri indikeres og transmitteres til central MCT-302, Dør/Vinduesender En af de mindste magnetkontaktsendere Ekstra indgang for trådført kontakt Sabotagekontakt på bagside alarmerer for fjernelse af senderen fra væg (model MCT-302T) 3 Volt standard Litiumbatteri for lang levetid Bærbare funktionshåndsendere Designet til bl.a. nødkald og styring af hjemme-automation 3 Volt standard Litiumbatteri for lang levetid Kan monteres med metalclips og bæres i bælte MCT-101 MCT-102 MCT trykknap (1 kanal) 2 trykknapper (2 kanaler) 4 trykknapper (4 kanaler) MCT-100, Universel trådløs sender Konverterer signaler fra trådførte kontakter til overvåget trådløs PowerCode signalering To indgange med individuel ID kode for hver indgang. Indgange Valgfrie som NC (normally closed), eller EOL (end of-line loop med NC eller NO kontakt) 3 Volt standard Litiumbatteri for lang levetid Trådløst tastatur MCT-201WP, Halskædesender Personlig nødkaldssender Vandtæt Lavt batteri indikeres og transmitteres til central 3 Volt standard Litiumbatteri for lang levetid MCM-140, Fjernbetjening Designet til nem fjernbetjening af mest anvendte funktioner i PowerMax + Attraktivt moderne ergonomisk design med option for vægmontage Tastatur er baggrundsbelyst og ses i mørke 3 Volt standard Litiumbatteri for lang levetid MCT-241, Halskædesender Personlig nødkaldssender Vandtæt, forseglet fra fabrik Lavt batteri indikeres og transmitteres til central 3 Volt standard Litiumbatteri for lang levetid Kan bæres i bælte med påsat bælteclips MCT-211, Håndledssender Personlig nødkaldssender Repeatere MCX-600, Trådløs Repeater Udvider rækkevidden af PowerCode baserede systemer Udviklet til at retransmittere data mellem trådløse PowerCode sendere og alarmcentralen Op til 16 Repeatere kan tilknyttes et enkelt system 9-Volt Nikkel kadmium genopladeligt backupbatteri Vandtæt Lavt batteri indikeres og transmitteres til central 3 Volt standard Litiumbatteri for lang levetid 11, PowerMax+
12 Head Office (Israel) Tel (+972-3) Fax (+972-3) Visonic Inc. (U.S.A.) Tel (+1-860) Fax (+1-860) Visonic Ltd. (U.K.) Tel ( ) Fax ( ) Visonic Iberica (Spain) Tel (+34-91) Fax (+34-91) Visonic GmbH (Germany) Tel ( ) Fax ( ) Visonic Deson (Hong Kong) Tel (+852) Fax (+852) Visonic Ltd. (Nordic) Tel (+47) Fax (+47) Visonic Sp.zo.o. (Poland & Central Eu.) Tel (+48-22) Fax (+48-22) Visonic Security Pty Limited (Australia) Tel (+61-2) Fax (+61-2) Web site: is a registered trademark of Visonic Ltd. Next, Discovery, PowerMax, PowerCode, Plug and Protect are trademarks of Visonic Ltd. All information correct at time of print. Visonic reserves the right to change information or specifications without notice. VISONIC LTD POWERMAX+CD5465S9 (Rev 5/04)
13 POWERMAX+ Fuldt overvåget trådløs alarmcentral Monteringsvejledning INDHOLD 1. INTRODUKTION SPECIFIKATIONER Generelle oplysninger RF afsnit Elektrisk specifikation Kommunikation Fysiske egenskaber INSTALLATION Udpakning af udstyret Strømforsyning af alarmcentralen Programmering Montering på væg Ledningsmontering Tilslutning af AC Transformer Installering af X-10 Sirene Montering af RS232 modul Forbindelse af PowerMax+ til GSM Modem PROGRAMMERING INTRODUKTION Generel orientering Indtastning af forkert Montør kode Montør Menu Opsætning af ny Montør kode Opsætning af ny Montør kode i PowerMax+ der har 2 Montør koder INDLÆSE TRÅDLØSE DETEKTORER OG HÅNDS Generel orientering indlæsningsmetode Indlæs/slet trådløse detektorer Indlæs/slet håndsendere Indlæs/slet trådløst tastatur Indlæs/slet trådløs sirene OPSÆTNING AF ZONETYPER, NAVNE & KLKE OPSÆTNING AF CENTRALENS PARAMETRE Indledende vejledning Indgangsforsinkelse 1& Udgangsforsinkelse Sirene tid Forsinket Alarm Alarm Annullering Hurtig tilkobling Isolering Genstart udgangsforsinkelse Ind/Ud Bip Problem Bip Panik Alarm Afbryd zone Krydsende zoner Overvågning IKKE KLAR AUX knap RF-støj Detektering Frakoblingsrapport Ikke Aktiv Baggrundslys Overfaldsalarm Intern Sirene Reset menu Sabotage rapport Sirene v/fejl Alarm indikering Frakobl menu Jam rapport Hånds. batteri Screen Saver Bekræftet Alarm tid Strømsvigt rapport Brugertilladelse OPSÆTNING AF KOMMUNIKATIONSPARAMETRE Tlf. Test tid Tlf. Test repetition Område nummer Bylinie Nr Kontrolcentral Tlf Kontonr Kontrolcentral Tlf Kontonr Rapport Format /2 Pulshastighed Rap. til kontrolcentral Bekrft. Alarm rapport Send 2VT Kode vejs tale med kontrolcentral Tilbagekaldstid Opkaldsforsøg til KC Privat Tlf. Nr vejs tale med privat telefon Opkaldsforsøg privat telefon Rapportering til privat telefon Telefon bekræftelse Pager Tlf. Nr Pager PIN Nr Rapport til Pager Nylig tilkobling Fjernbetj. Adg Download kode Central ID Zone Reset Upload valg...19 DD5467IP 1
14 Opkaldsmetode Tlf. fejl rap Telf. Fejl Rapport UL/DL Telefonnummer System Inaktivt Rapport Modopkalds kode OPSÆTNING AF GSM PARAMETRE GSM installeret SMS telefonumrene Rapport til SMS GSM Netforbindelse Rapport GSM formål OPSÆTNING AF UDGANGSPARAMETRE Indledende vejledning Opsæt PGM Opsæt INT udgang Opsæt X-10 funktioner Opsæt X-10 enheder OPTAGE TALE TILSTANDSTEST BRUGERFUNKTIONER GENKALD FABRIKSOPSÆTNING SERIENUMMER RING OP TIL UPLOAD/DOWNLOAD SERVER TEST PROCEDURER Forberedelser Tilstandstest Håndsender Test TIL/FRA Test af enheder Test af nødkaldssendere VEDLIGEHOLD Afmontering af Alarmcentralen Udskiftning af Backup Batteri Udskiftning af sikring Udskiftning/flytning af detektorer AFLÆSNING AF HÆNDELSESLOG...26 APPENDIKS A. PLACERING AF DETEKTORER OG HÅNDSENDERE...27 A.1 Plan over detektorernes placering...27 A.2 Håndsenderliste...28 A.3 Nødkaldssenderliste...28 A.4 Ikke-Alarm Sender List...28 APPENDIX B. APPENDIX B. X-10 ENHEDER OG PGM UDGANGS ANVENDELSE...28 APPENDIKS C. HÆNDELSESKODER...29 APPENDIKS D. PROGRAMMERBARE ZONETYPER...31 APPENDIX E. POWERMAX+ KOMPATIBLE ENHEDER 32 E1 PowerMax+ kompatible Detektorer...32 E2 PowerMax+ kompatible håndsendere...32 E3 PowerMax+ kompatibel trådløs Sirene...33 E4 PowerMax+ kompatibelt GSM Modem...33 FCC Statements...34 Declaration of Conformity...35 Meddelelse til montøren PowerMax alarmcentralen leveres med 2 manualer: Monterings- og Programmeringsvejledning (denne manual alene til dit brug) Brugervejledning (Anvendes kun af dig under monteringen). Efter afslutning af testen skal brugervejledningen overdrages til superbrugeren. Appendiks A og B hjælper dig med at forberede en monteringsplan. Hvis du tager dig tid til at udfylde skemaerne, vil det lette dig i den videre montering og risiko for sammenblanding vil minimeres. Skemaerne kan også være en hjælp ved udarbejdelse af en liste over detektorer og sendere, som skal anvendes i installationen. Kompatible detektorer og sendere er oplistet og kort beskrevet i Appendiks E i denne vejledning. Husk Det anbefales at slutte strøm til alarmcentralen midlertidig på en arbejdsbænk i overensstemmelse med monteringsplanen. De enkelte trin i programmeringen viser alle valgmuligheder for hver parameter. Fabriksindstillinger er markeret med en sort boks i højre side og øvrige muligheder (de som kan vælges i stedet), er markeret med en hvid boks. Dette gør det muligt at sætte et flueben i den aktuelt valgte hvide boks, hvor denne afviger fra fabriksindstillingen. Selvom indstilling af tid og dato skal foretages af brugeren, anbefales det, at du indstiller tid og dato under programmeringen. Adgang til Brugerindstillinger er muligt gennem punkt 9 i montørmenuen (se Brugervejledningen for den præcise procedure). Når du har gennemgået programmeringen, fortsæt med at montere systemet som anført i Monteringsvejledningen fra afsnit 3.4 og fremefter. Montøren bør forsikre sig om korrekt telefonlinie forbindelse. Vær opmærksom på andre telefonservices, så som ADSL. 2 DD5467IP
15 1. INTRODUKTION PowerMax er en bruger- og monteringsvenlig 30 zoners fuldt overvåget trådløs alarmcentral. Systemet er udviklet til at gøre brugen af alarmcentralen let for brugeren og tilbyder samtidig funktioner, som gør monteringen lettere end nogensinde. LET AT MONTERE Plug-in terminaler kan ledningsmonteres afsondret fra enheden. Hurtige tilslutninger/afmonteringer via TELCO sokler til telefon og X-10 kontroller. Specielt beslag til væg-montering gør monteringen mulig uden at åbne enhedens kabinet. Mulighed for RS-232 Plug-in modul ved tilslutning til PC. LET AT VEDLIGEHOLDE Status- og alarmhukommelse, samt oplysning om problemer, vises på skærmen på opfordring. 2. SPECIFIKATIONER 2.1 Generelle oplysninger Antal zoner: 28 trådløse, 2 trådførte (zone Nr. 29 & 30). trådførte zone (krav): 2.2kΩ E.O.L. modstand (max. Lednings modstand 220Ω). Zonetyper: Indvendig følge, indvendig, perimeter, perimeter følge, forsinket type 1, forsinket type 2, 24 timer akustisk, 24 timer tavs, brand, ikke-alarm og nødalarm, gas og vand. Brugerkoder: 8 koder, hver med 4 cifre. Alarmcentralfaciliteter: - Indbygget tastatur - PowerCode / CodeSecure håndholdte sendere - Trådløst Tastatur, MCM Fjernbetjening via telefon - lokal eller fjernbetjening via computer. Display: Enkelt linie, bag-belysning, 16 karakterer LCD og 4 LED indikatorer. Tilkoblingsmåder: Fuld Tilkobling, Nat Tilkobling, (skalsikring), Straks Tilkobling, Straks Nat Tilkobling, Tilkobling m/frakoblingsrapport, Tvungen Tilkobling. Alarmtyper: Tavs alarm, sirenealarm eller via indbygget sirene, afhængig af zoneegenskaberne. Sirenesignaler: Kontinuerlig (indbrud / 24 timer / panik); Tredobbelt puls pause tredobbelt puls (brand). Sireneudløb: Programmerbar (fabriksindstilling: 4 min.) Indbygget sireneudgang: mindst 85dBA ved 3m Overvågning: Programmerbar tidsramme for alarm ved inaktivitet. Specielle funktioner: - Tale- og lyd kontrol - Powerline kommunikation: Styring af op til femten (15) X-10 enheder, der kan reagere på forskellige hændelser, afhængig af programmeringen - Kime/klokke funktion for zoner - Tilstandstest og begivenhedsjournal - Fjernbetjening via telefon - Betjening via PC samt download/upload af oplysninger - Tilkalde hjælp via en nødkaldssender. - Overvåge gamle mennesker, fysisk handicappede og svagelige, der er afhængig af hjælp. - Meddelelsescenter (optag og afspil meddelelser) - To-vejs kommunikation Test af detektorernes tilstand giver synlig og akustisk indikation af signalstyrken på hver detektor. Fjernbetjening og oplysninger om systemets status via telefonnettet. Hændelseslog gemmes og informationerne på de seneste 100 hændelser kan vises. Upload/download til/fra ekstern computer via modem over telefonnettet. HURTIG PROGRAMMERING Flere valgmuligheder for hver parameter. Klare og overskuelige påmindelser og akustiske signaler. Montøren har adgang til brugermenuen. En fuldt udstyret alarmcentral baseret på PowerMax+ er vist i Figur 2 i brugervejledningen. Data opsamling: Status, alarmhukommelse, problem og hændelsesjournal. Realtids ur: Alarmcentralen viser tid og dato. Opfylder følgende EU-standarder: EMC Emission: EN , EN RFI: EN EMC Immunitet: EN , EN EMC Immunitet overfor RF: EN Telefoni: TBR Sikkerhed: EN Am1(93), Am2(93), Am3(95), Am4(97) I følge europæisk standard EN50131, er PowerMax+ graderet til sikringsklasse 2 "lav til medium risiko" og miljøklassificeringen er: II "indendørs generelt". PowerMax er kompatibel med RTTE krav direktiv 1999/5/EC fra EU-parlamentet og råd af 9. marts RF afsnit Frekvens: 868,95 MHz eller andre UHF kanaler som bruges i anvendelseslandet. Modtagertype: Super-heterodyne, fast frekvens Modtagelsesrækkevidde: 180m over åben mark Antennetype: Spatial Diversity Kode: PowerCode og/eller CodeSecure 2.3 Elektrisk specifikation Strømforsyning: Plug-in transformer: 230VAC, 50Hz / 9VAC, 700mA eller: 230VAC, 50Hz / 9VAC, 1A Bemærk: 700mA transformer kan bruges hvis udvendig sirenes strømforbrug er mindre end 300 ma. I Europa: Brug kun nationalt godkendte AC adaptere, 230V-til-9 VAC, 0.7A eller 1A. Strømforbrug: Ca. 65 ma standby, 800 ma ved fuld belastning og i alarm. Extern Sirene strømforbrug (EXT): 550* ma 10.5 VDC ved forsyning fra AC & DC (batteri). Intern Sirene strømforbrug (INT): 550* ma 10.5 VDC ved forsyning fra AC & DC (batteri) DD5467IP 3
16 PGM Output forbrug: 100* ma max. Detektor 1 & 2 Total (Sum) strømforbrug: 100* ma max. Strøm og kortslutningsbeskyttelse: Alle udgange er beskyttede med Strømbegrænsning. * Totale PowerMax+ strømforbrug (for INT & EXT sirener, PGM udgang og detektorer) kan ikke overstige 600 ma. Totale INT & EXT sirener strømforbrug kan ikke overstige 550 ma. Backup Batteri (yder strømforsyning i mindst 24timer), afhængig af den aktuelle batterioption: Option 1: 7.2V 2100 mah, genopladeligt NiMH batteri, p/n GP211ATH6XM2, fremstillet af GP, lader ca. 80 ma. Option 2: 9.6V Nikkel Cadmium eller Nikkel Metal genopladelig batteripakke, 650 til 1800 mah. Bemærk: ved brug af en batteripakke ikke leveret af Visonic, skal korrekt polaritet på batteripakkens snapkontakt påses. Batteritest: Hvert 10. sekund. 3. INSTALLATION 3.1 Udpakning af udstyret Åben emballagen og kontrollér om sættet er komplet. Hvis du konstaterer mangler, skal du straks kontakte din forhandler. 3.2 Strømforsyning af alarmcentralen Indlæsning af sendernes identifikationskoder i hukommelsen på PowerMax+ er lettere, når alle detektorer er på en arbejdsbænk nær alarmcentralen, forinden den endelige montering. Det er derfor nødvendigt at tilslutte alarmcentralen til ledningsnettet, se figur 3-3, eller backupbatteriet som vist i figur 3-1. Ignorer de problem meddelelser, som måtte opstå (som følge af manglende backupbatteri og tilslutning til telefonstik). 3.3 Programmering Det anbefales at opstille en plan ved hjælp af appendiks A og B forud for programmeringen således, at den planlagte placering af de enkelte detektorer samt hvilke personer, der har hvilke håndsendere registreres. Saml alle håndsendere og detektorer, der anvendes i systemet og marker hver enkelt i overensstemmelse med fordelings-/opsætningsplanen. Der henvises til programmeringsmanualen for nærmere oplysninger om programmering af PowerMax Montering på væg Monteringen af PowerMax+ på væggen, er vist i figur Ledningsmontering Monteringen af ledningsforbindelser til PowerMax+, er vist i figur 3-3. Udtag Plug-in terminalerne en af gangen, monter ledningerne, og tryk terminaler tilbage på deres pladser. Til montering af telefonstik skal der anvendes følgende: 6-leder ledning med farvekode ledere. 8-leder ledning med farvekode ledere. To 6-leder RJ-11 stik og en 8-leder RJ-31X stik for at forbinde ledningerne til PowerMax. Værktøj til 6-leder og 8-leder RJ-11 stik. 2.4 Kommunikation Indbygget modem: 300 baud, Bell 203 protokol Dataoverførsel til lokal computer: Via RS232 seriel port Bestemmelsessted for rapport: 2 kontrolcentraler, 4 private telefoner, 1 personsøger Rapporteringsformat: SIA, Pulse 4/2 1900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Scancom. Puls sats: 10, 20, 33 og 40 pps programmerbar Besked til private telefoner: Tone eller stemme Besked til personsøger: PIN Nr.Alarm type Zone Nr. 2.5 Fysiske egenskaber Funktionstemperatur: 0 C til 49 C Opbevaringstemperatur: -20 C til 60 C Fugtighed: 85 % relativ fugtighed ved 30 C Størrelse: 250 x 190 x 44 mm Vægt: 880 g uden batterier Farve: Elfenben og trækulsgrå 1 2 Åben lågen 3 F o r b i n d genopladelig batteripakke til b a t t e r i konnektoren (se label på batterilåge). Sæt dækslet på med skruen og luk lågen. Fjern skruen og dækslet Figur 3-1 Montering af Backup Batteri 4 DD5467IP
17 AFTAGELSE AF BESLAG 1 Udtag beslagets låseskrue 2 Træk beslaget ned til der høres et klik 3 Fjern beslag MONTERING AF BESLAG MONTERINGSFLADE Skrue huller MONTERING AF CENTRALEN Skrue huller 4 Marker og bor 4 huller i monteringsfladen. Isæt rawlplugs og fastgør beslaget til monteringsfladen med 4 skruer. NOTE Det skal tilsikres at der er mindst 3 cm fri plads omkring beslaget. 5 Placer centralen på beslagets tappe. Skub centralen nedefter til den er på plads på beslaget, og fastgør låseskruen igen (se trin 1). Figur 3-2 Ophængning af Central DD5467IP 5
18 FORBIND TRÅDFØRTE DETEKTORER SOM ANVIST: Detektor med Detektor uden sabotage kontakt sabotage kontakt Sabotage Alarm Alarm N.C. N.C. Spænding - + N.C. Power kω ZONE 29 / ZONE 30 GND V+(*) 2.2 kω ZONE 29 / ZONE 30 GND V+(*) Note: Vedrørende zonerne 29 & 30 ser PowerMax+ en specifik modstand afhængig af hændelsen som følger: Normal (ingen alarm & ingen sabotage): 2.2kW. Alarmhændelse: 4.4kW. Sabotage hændelse: Uendelig modstand. TRANSFORMER TLF LINIE 6-LEDER RJ-11 STIK (*) (*) ZONE 29 (*) GND ZONE 30 (*) RØD GRØN BRUN GRÅ V+ (***) X-10 (**) (**) (**) (**) (**) -HOLD EXT INT +12V +12V PGM 9 VAC INTERN SIRENE ELLER STROBELYS EKSTERN SIRENE POWERLINE INTERFACE MODUL RØD & GRØN TIL LINE BRUN & GRÅ TIL SET RJ-31X KABEL 6-LEDER RJ-11 STIK VIGTIGT! Færdigt konfektionerede kabler er ikke anvendelige her. Fremstil dit eget 1 til 1 kabel. Bemærkninger til figur 3: * Zone 29/GND og Zone 30/GND terminalerne kan forbindes til en NC kontakt på en detektor, en sabotage kontakt på en detektor eller anden enhed, eller en trykkontakt via en 2.2 KΩ modstand. En sådan modstand er fra fabrikken monteret på såvel Zone 29/GND som Zone 30/GND terminalerne. Modstandene skal blive siddende, hvis disse indgange ikke anvendes. V+ terminalen kan forsyne 12V (op til 100mA) til en detektor. ** Begge +12V terminalerne er sammenbundne. +12V og "-Hold" terminalerne kan forbindes til en sirene (for konstant DC strømforsyning) og INT eller EXT terminalen kan bruges til at trigge en sådan sirene. INT terminalen kan programmeres som "intern sirene" eller som "strobe" (se OPSÆT UDGANGSPARAMETRE i afsnit 4.7 i PowerMax+ programmeringsvejledning). 8-LEDER RJ-31X STIK Figur Wiring Diagram *** X-10 jumper skal sidde i 1-W position (for 1-vejs power line interface unit) eller i 2-W position (for 2-vejs power line interface unit). ADVARSEL! Når terminalerne trykkes på plads, vær da omhyggelig med at de passer præcist på benene på Printet. Forkert eller omvendt isætning af terminaler kan beskadige interne kredsløb i PowerMax+. VIGTIGT! Terminalerne til den interne og den eksterne sirene er DC udgange beregnede til 12V sirener. Montering af en Højttaler til en eller begge disse udgange, vil forårsage en kortslutning, og vil beskadige centralen. 6 DD5467IP
19 3.6 Tilslutning af AC Transformer ADVARSEL! Tilslut ikke transformeren til ledningsnettet inden den øvrige ledningsmontering er gennemført og afsluttet. Sæt transformeren i stikkontakten alarmcentralens POWER LED begynder at lyse. Afstanden mellem transformeren og alarmcentralen bør ikke overstige 50 meter (18 AGW). 3.7 Installering af X-10 Sirene Hvis der opstår behov for en Trådløs ekstern sirene, er det muligt at installere en X-10 styret sirene, der trigges af et signal der transmitteres via den eksisterende elektriske installation i det sikrede område. Sirenen kan erstatte den normale eksterne sirene eller komplementere den, uden at skulle installere yderligere kabler. En sirene styret af X-10 kommunikation fra PowerMax+, kan kun anvendes sammen med et Powerline interface modul mellem PowerMax+ og den elektriske installation. X-10 sirenen er klar til brug straks når den er forbundet til den elektriske installation, uden omprogrammering af PowerMax+. Blot skal HUSKODE og ENHEDSKODE vælgerne på X-10 sirenen sættes som følger: Huskode: Sæt denne vælger til det bogstav, der I alfabetisk rækkefølge kommer efter det bogstav der blev programmeret som Huskode for det beskyttede område. For eksempel, hvis den programmerede Huskode er J, skal sirenens Huskode vælger sættes til K. Bemærk: Hvis den programmerede Huskode er P (som er det sidste bogstav der kan programmeres), skal A vælges for sirenen. 4. PROGRAMMERING 4.1 INTRODUKTION Generel orientering Det anbefales, at PowerMax+ programmeres på en testbænk inden endelig montering. Strømforsyning kan enten komme fra backupbatteriet eller ledningsnettet. Det er alene de personer, som kender montørkoden, der fra fabrikken er indstillet til 9999, som kan opnå adgang til montørmenuen. For PowerMax+ centraler der har 2 montør koder, er default MONTØR koden 8888, og default MASTER koden er Følgende handlinger kan kun udføres ved anvendelse af master kode: Ændre master koden. Reset af PowerMax+ parametre til Fabriksparametre. Definere specifikke kommunikationsparametre, som angivet i noten i figur 5. Denne kode skal imidlertid kun anvendes én gang for at opnå adgang den første gang koden skal erstattes af en hemmelig kode, som kun du kender. Du vil hovedsagelig anvende 5 kontroltaster under programmeringen: Enhedskode: sirenen vil kun fungere hvis Enhedskode vælgeren sættes til Montering af RS232 modul Alarmcentralen kan udstyres med et RS232-modul, som gør det muligt at udveksle data med en lokal computer. Når modulet ikke bruges, anvendes det medfølgende plastikdæksel til at blokere for indsætning af ledninger. Bemærk: For at kunne download e data fra en lokal computer, skal PowerMax+ være logget ind i Montør menuen. 1 2 Fjern plastik dæksel RJ-45 or RJ-31X (USA) Tryk RS-232 adapteren på plads i hanstikket, indtil der høres et klik. Figur Forbinde PowerMax+ til en Computer 3.9 Forbinde PowerMax+ til GSM Modem GSM enheden gør det muligt for PowerMax+ at kommunikere over et Mobil netværk. For yderligere information om GSM modem funktion og forbindelse, se nærmere i GSM Modem installationsmanualen. VIS / For at gå videre i et givet menupunkt. For at gå tilbage i et givet menupunkt. For at gå et niveau ned i menupunktet eller til at bekræfte oplysninger. For at gå et niveau op i menupunktet i programmeringsstrukturen. Øjeblikkelig returnering til montørmenu (start niveau). De lyde, som du vil høre under programmeringen er: Enkelt bip, høres hver gang du trykker en tast. Dobbelt bip, indikerer automatisk tilbagevenden til normal funktion (ved tids udløb). Succesmelodi (- - - ), indikerer en succesfuld afslutning af en funktion. Fejlmelodi ( ), indikerer en fejlagtig indtastning eller afvisning af indtastningen Indtastning af forkert montørkode Hvis der indtastes en forkert montørkode 5 gange, vil tastaturet automatisk blive spærret i 30 sekunder. DD5467IP 7
20 4.1.3 Montør Menu Montør menuen er vist i figur 4.1.a. Teksten i rektanglerne, repræsenterer det aktuelle PowerMax+ display Opsætning af ny Montør kode For at opsætte en ny Montørkode, skal handlingerne der er præsenteret i figur 4.1.b udføres. Når centralen beder om at indtaste kode, indtast da en 4-cifret kode Opsætning af ny montørkode i PowerMax+ der har 2 montørkoder For PowerMax+ centraler med 2 koder, MONTØR kode og MASTER kode, opsættes nye koder som vist i figur 4.1.c. For nærmere information om menuadgang ved brug af Montør og Master montør kode ved indlogning, se note i figur 4.5 (OPSÆT KOMM). Master Montørkode, vil tillade ændring af både master kode og montørkode. Montørkoden vil alene tillade ændring af montørkoden. Første display er KLAR eller IKKE KLAR KLAR 00:00 NORMAL MENU BRUGER MENU MONTØR MENU INDTAST KODE: [Montør kode] 1. NY MONTØR KODE (Se fig. 4.1b & 4.1c) 2. INDLÆSNING (Se figur 4.2) 3. OPSÆT ZONER (Se figur 4.3) 4. OPSÆT CENTRAL (Se figur 4.4) 5.OPSÆT KOMM. (Se figur 4.5) 6. OPSÆT GSM (Se figur 4.6) 7.OPSÆT UDGANGE (Se figur 4.7 ) 8.OPTAG TALE (Se figur 4.8) 9.TILSTANDSTEST (Se figur 4.9) 10.BRUGEROPSÆTN. (Se afsnit 7 i Bruger Manual) 11.FABRIKSOPSÆTN (Se afsnit 4.11) (PowerMax+ 12. SERIENUMMER Serienummer visning) 13. START UL/DL (Se afsnit 4.13) <> FOR AFSLUT Figur 4.1a - Installatør Menu (Se fig. 4.1a) 1. NY MONTØR KODE NY MONTØR KODE MONTØR KODE xxxx [kode] Figur 4.1b - Opsætning af ny Installatør kode (se note) Ved brug af Montør kode (se fig. 4.1a) 1. NY MONTØR KODE NY MONTØR KODE MONTØR KODE xxxx [kode] Ved brug af Master kode (se fig. 4.1a) 1. NY MONTØR KODE NEW MASTER CODE NY MONTØR KODE MASTER CODE xxxx MONTØR KODE xxxx [code] [kode] Figur 4.1c - Opsætning af ny Montør kode i Central med Montør & Master koder (se note) Note: Master montør koden må ikke sættes til Det er IKKE en tilladt kode. Den vil ikke give adgang til Montør menuen. 8 DD5467IP
21 4.2. INDLÆSNING AF TRÅDLØSE DETEKTORER OG HÅNDSENDERE Generel orientering Indlæsningsmenuen har 5 undermenupunkter: INDLÆSN. METODE (trådløse enheder) INDLÆS DETEKTOR INDLÆS HÅNDSEND. (multi-funktions CodeSecure transmitter) INDLÆS TASTATUR (trådløst tastatur/commander) INDLÆS SIRENE (trådløs sirene) Indsaml alle enheder som skal indgå i installationen før der foretages yderligere, og sørg for, at de alle har batterier monteret. alarmsystemet skal genkende de unikke identifikationskoder (ID er) på hver enhed, for at kunne modtage deres signal, overvåge dem og reagere herpå. Bemærk! CodeSecure transmittere bruges hovedsageligt for til/frakobling, og kan ikke indlæses til zoner. Til zoner indlæses udelukkende trådløse PowerCode og andre ikke-codesecure enheder. (*) INDLÆS TYPE INDLÆS DETEKTOR INDLÆS HÅNDSEND. normal indlæs v/sab. kontakt SÆT FØLSOMHED Håndsender Nr: - HØJERE FØLSOMH. LAVERE FØLSOMH. Vælg ved eller ZONE Nr: - - (****) [Håndsender Nr.] (f.eks. 5) (**) HÅNDSEND NR: 5 HÅNDSEND NR: 5 (Tryk på en tast) (**) <OFF> FOR SLET [Zone Nr.] (f.eks. 05) Første display er KLAR (**) eller IKKE KLAR ZONE Nr: 05 ZONE Nr: 05 KLAR 00:00 HÅNDSEND NR: 5 HÅNDSEND NR: 5 NORMAL MENU SEND NU for <OFF> FOR SLET næste indlæsning (***) BRUGER MENU [Aktiver transmission] Indlæs en trådløs enhed Slet en trådløs enhed (**) MONTØR MENU ZONE Nr: 05 ZONE Nr: 05 for INDTAST KODE: næste indlæsning [Montør kode] Indlæs en trådløs enhed Slet en trådløs enhed 1. NY MONTØR KODE INDLÆS TASTATUR INDLÆS SIRENE 2. INDLÆSNING 3. OPSÆT ZONER TASTATUR NR: SIRENE Nr: [TL 1-vejs TASTATUR TL SIRENE NR. 4. OPSÆT CENTRAL NR. 1 til 8 (f.eks. 5) (**) 1 eller 2 (f.eks. 2) (**) TASTATUR NR: 5 TASTATUR NR: 5 SIRENE NR: 2 SIRENE NR: 2 5.OPSÆT KOMM. 6. OPSÆT GSM SEND NU <OFF> FOR SLET SEND NU <OFF> FOR SLET (tryk indtil* Tryk kort på den trådløse 7.OPSÆT UDGANGE sirenes selv-test knap rød indtil et squawk høres LED 8.OPTAG TALE (ca. 1 sek.) lyser) TASTATUR NR: 5 SIRENE NR: 2 SIRENE NR: 2 9.TILSTANDSTEST for TASTATUR NR: 5 næste indlæsning 10.BRUGEROPSÆTN. for Slet en trådløs næste indlæsning fjernbetjening MCM-140+ Indlæs en Slet en trådløs sirene trådløs sirene 11.FABRIKSOPSÆTN Indlæs en trådløs fjernbetjening MCM SERIENUMMER (*) Indlæsning af håndsender kan gøres af montøren eller af brugeren (via Brugeropsætnings menuen) (**) En sort firkant i displayet betyder at denne enhed er indlæst (Systemet har lært enhedens ID) 13. START UL/DL (***) Aktiver transmission med enhedens sabotage kontakt KUN hvis Sabotage Rapport er valgt (se figur 4.4, lokation 25) Hvis Sabotage Rapport er fravalgt, aktiver da transmission ved at udløse en detektering fra enheden. Hvis enheden ingen sabotage kontakt har, tryk da på dens transmissionsknap. <> FOR AFSLUT (****) Vælg højere følsomhed ved trådløse enheder længere væk, lavere følsomhed for nære enheder. DD5467IP 9 SEND NU Figur Indlæsning / sletning af trådløse detektorer / håndsendere / trådløse tastaturer / trådløse sirener
22 4.2.2 Indlæsningsmetode I Indlæsningsmetode vælges det om indlæsning af trådløse detektorer udføres ved normal transmission, eller ved at aktivere enhedens sabotagekontakt. (normalt ved at åbne dækslet). Vælg mellem: NORMAL INDLÆS, eller V/SAB. KONTAKT Indlæs/slet trådløse detektorer Trådløse detektorer omfatter forskellige trådløse PowerCode detektorer og håndsendere. Linserne på PIR og dual detektorer skal afskærmes for at forhindre uønsket transmission. Sæt elastik omkring magnetkontakterne og magneten for at undgå at de afgiver uønsket alarm For at indlæse/slette trådløse detektorer, se figur Indlæs/slet håndsendere Håndsendere er multi-funktions trådløse CodeSecure transmittere. Op til otte brugere kan anvende hver deres håndsender. Håndsenderen giver bedre, hurtigere og mere sikker kontrol over forskellige systemfunktioner. For at indlæse/slette trådløse håndsendere, se figur Indlæs/slet trådløst tastatur Det trådløse tastatur er en fjernbetjeningsenhed der giver brugeren mulighed for at styre visse funktioner i PowerMax+ centralen. For at indlæse/slette op til 8 trådløse tastaturer, se figur 4.2 (INDLÆS TASTATUR) Indlæs/slet trådløs Sirene Den trådløse sirene er en fjernaktiveret sirene der aktiveres af PowerMax+ systemet, ved forud definerede hændelser. For at indlæse/slette op til 2 trådløse sirener, se figur OPSÆTNING AF ZONE TYPER, NAVNE & KLKE ZONER Dette menupunkt giver mulighed for at programmere en af 13 zonetyper til en hvilken som helst af de i alt 30 zoner (29 trådløse og 1 trådført), som PowerMax+ arbejder med. Herudover kan du tilføje et navn til hver zone, og bestemme om zonen skal fungere som en dørklokke zone mens systemet er frakoblet eller tilkoblet i Nat tilkobling. Når en dørklokke zone aktiveres, vil der lyde en klokke melodi eller zonens navn vil blive talt. (der er 3 valgmuligheder: Melodi klokke, Zone Navn eller Dørklokke fra). KLAR 00:00 NORMAL MENU BRUGER MENU MONTØR MENU INDTAST KODE: [Montør kode] 1. NY MONTØR KODE 2. INDLÆSNING 3. OPSÆT ZONER 4. OPSÆT CENTRAL 5.OPSÆT KOMM. 6. OPSÆT GSM 7.OPSÆT UDGANGE 8.OPTAG TALE 9.TILSTANDSTEST 10.BRUGEROPSÆTN. 11.FABRIKSOPSÆTN 12. SERIENUMMER 13. START UL/DL <> FOR AFSLUT Første display er KLAR eller IKKE KLAR ZONE Nr: - - [Zone Nr.] (f.eks. 05) Zxx: TYPE - 1. Indvendig Flg 2. Perimeter 3. Perimeter Flg 4. Forsinket 1 5. Forsinket t Tavs 7. 24t Sirene 8. Brand 9. Ikke-Alarm 10. Nødkald 11. Gas 12. Vand 13. Indvendig (*) En liste over fabriksindstillede parametre, er vist i tabel 1. Du kan udfylde de blanke felter før du påbegynder programmering i overensstemmelse med din egen liste. Husk! En forsinket zone er pr. definition også en perimeterzone. Bemærk! SKAFOR godkendte installationer skal have mindst en zone med forsinkelse for at kunne frakobles. Zone typer er forklarede detaljeret i Appendiks D. Zonenavne Der kan vælges 31 zonenavne, 26 faste navne og 5 Bruger Zoner (vælges af montøren se afsn. 8) Pulterkammer Bagdør Kælder Badeværelse Soveværelse Børneværelse Toilet Stuedør Spisestue Gang Nødkald Brand Fordør Garage Garagedør Gæsteværelse Zxx: NAVN - - (Se liste ovenfor) (*) Zxx: DØRKLKE Melodi-klokke Zonenavn-klokke Klokke fra (*) 10 DD5467IPP Entre Køkken Vaskerum Stue Vindue Badevær. Soveværelse Dør Kontor Værelse Pulterkammer Bagdør Kælder Badeværelse Soveværelse Børneværelse Toilet Bryggers Udestue Bruger Zone 1 Bruger Zone 2 Bruger Zone 3 Bruger Zone 4 Bruger Zone 5 Figur OPSÆT ZONER Overbliksskema * Fabriksindstillede parametre er disse der er markerede med en mørk box i højre side. For at se valgmulighederne, klik på eller knappen, indtil den ønskede mulighed vises, klik på. En mørk box vises i højre side. ** Et klik på knappen i denne lokation bringer dig tilbage til den samme zone du behandler. Tryk eller for at vælge den næste zone. (**)
23 Zone Nr. Zonetype (fabriksindstilling) FABRIKSINDSTILLING OG PROGRAMMEREDE DEFINITIONER Programmeret zonetype Zonenavn (fabriksindstilling) Programmeret Zonenavn Dørklokke J / N * 1 Forsinket 1 Fordør 2 Forsinket 1 Garage 3 Forsinket 2 Garagedør 4 Perimeter Bagdør 5 Perimeter Børneværelse 6 Indvendig Kontor 7 Indvendig Spisestue 8 Perimeter Spisestue 9 Perimeter Køkken 10 Perimeter Stue 11 Indvendig Stue 12 Indvendig Soveværelse 13 Perimeter Soveværelse 14 Perimeter Gæsteværelse 15 Indvendig Soveværelse dør 16 Perimeter Soveværelse dør 17 Perimeter Vaskerum 18 Perimeter Vindue badeværelse 19 Perimeter Kælder 20 Brand Brand 21 Brand Brand 22 Nødkald Nødkald 23 Nødkald Nødkald t / tavs Kælder t / tavs Kontor t / akustisk Pulterkammer t / akustisk Stuedør 28 Ikke-alarm Udestue 29 Ikke-alarm Entre 30 ikke-alarm Bryggers * Bemærk: Alle zoner er ikke-dørklokke fra fabrikken. Indtast dit eget valg i den sidste kolonne og programmer i overensstemmelse hermed. * I en SKAFOR godkendt installation skal systemet indeholde mindst 1 zone med forsinkelse for at kunne frakobles. 4.4 OPSÆTNING AF ALARMCENTRALENS PARAMETRE Indledende vejledning Dette menupunkt giver mulighed for at foretage en opsætning af alarmcentralen, med de karakteristika og reaktioner, som den enkelte bruger har behov for. Et illustreret forløb af denne opsætning er vist i figur 4.4. Den i øjeblikket valgte parameterværdi er vist med en mørk boks i højre side. Hvis du ønsker at vælge en anden værdi, kan du gense de andre muligheder ved at taste <> eller <BACK> gentagne gange. De muligheder, som ikke aktuelt er valgt har en ledig plads. Vælg den ønskede værdi ved tryk på VIS/ knappen. En mørk boks i højre side markerer valget Indgangsforsinkelse 1 & 2 (fig. 4.4, lokation 01, 02) To forskellige indgangsforsinkelser giver brugeren mulighed for, at komme ind i det beskyttede område, (mens systemet er tilkoblet) via 2 specifikke døre og ruter, uden at aktivere alarmen. Efter udgang skal brugeren frakoble alarmcentralen inden udløbet af indgangsforsinkelsen. Langsomme bip vil lyde, når døren bliver åbnet. Disse vil fortsætte indtil de sidste 10 sek. af forsinkelsen, hvorefter der skiftes til hurtige bip. Lokation nr. 1 (indgangsforsinket 1) og 2 (indgangsforsinket 2), giver dig mulighed for at programmere længden af disse forsinkelser. Der er følgende muligheder for hver forsinkelse: 00s, 15s, 30s, 45s, 60s, 3m og 4m. Bemærk! I SKAFOR versionen kan der kun vælges 10, 15 eller 30 sekunder Udgangsforsinkelse (fig. 4.4 lokation 03) En udgangsforsinkelse giver brugeren mulighed for, at tilkoble systemet og forlade det beskyttede område via specifikke ruter og døre, uden at aktivere alarmen. DD5467IP 11
24 Langsomme bip vil lyde, når systemet bliver tilkoblet. Disse vil fortsætte indtil de sidste 10 sekunder af forsinkelsen, hvorefter der skiftes til hurtige bip. Lokation nr. 3 giver dig mulighed for, at programmere længden af disse forsinkelser. Der er følgende muligheder for hver forsinkelse: 30s, 60s, 90s, 120s, 3m og 4m. Bemærk! I en SKAFOR godkendt installation må udgangsforsinkelsen maksimalt være 30 sekunder Sirene tid (fig. 4.4, lokation 04) Her vælger du hvor lang tid sirenen skal lyde i tilfælde af alarm. Sirenetiden starter når alarmen aktiveres. Sirenen bliver automatisk afbrudt, når sirenetiden, indstillet i denne lokation, udløber. Valgmulighederne er: 1, 3, 4, 8, 10, 15 og 20 minutter Forsinket alarm (fig. 4.4 lokation 05) Her vælger du hvor lang tid systemet skal forsinke alarmen, i hvilken periode du har mulighed for at afbryde alarmen. (anvendes ikke ved alarm fra BRAND, 24T TAVS og NØDKALDS zoner). PowerMax+ er programmeret til at forsinke alarmen i en periode, når en alarm detekteres. Under denne periode, vil buzzeren afgive en advarsel, men sirenen aktiveres ikke, og alarmen rapporteres ikke. Hvis brugeren frakobler systemet inden for den tilladte tidsperiode, indstillet i denne lokation, vil alarmen blive afbrudt. Valgmulighederne er: 00s, 15s, 30s, 45s, 60s, 2m, 3m og 4m. Bemærk! I SKAFOR versionen kan der kun vælges 00, 15 eller 30 sekunder Alarm annullering (fig. 4.4, lokation 06) Her fastsætter du alarm annulleringstiden, som påbegyndes ved rapportering af alarm til kontrolcentralen. Hvis brugeren frakobler systemet inden udløbet af tiden, indstillet i denne lokation, vil PowerMax+ afgive en alarm annulleret meddelelse til kontrolcentralen. Valgmulighederne er: 1, 5, 15, 60min, 4tim samt Ingen annullering Hurtig tilkobling (fig. 4.4, lokation 07) Her bestemmer du, om brugeren skal have tilladelse til at udføre en hurtig tilkobling. Når hurtig tilkobling er tilladt, vil alarmcentralen ikke anmode om indtastning af kode før systemet tilkobles. De to valgmuligheder er: Hurtig tilk. Til og Hurtig tilk. Fra Isolering (fig. 4.4, lokation 08) Her bestemmer du, om brugeren skal have tilladelse til at udføre enten en manuel isolering af individuelle zoner (via OPSÆT CENTRAL Menuen), eller tillade tvungen tilkobling af systemet, som udfører automatisk isolering af de zoner, som er åbne under udgangsforsinkelsen. Forsinkelses bip der lyder under tvungen tilkobling kan elimineres ved at trykke to gange på AWAY. Hvis en zone er åben og tvungen tilkobling ikke er tilladt, vil IKKE KLAR blive angivet i displayet og systemet vil ikke blive tilkoblet (fejlmelodien lyder). Hvis ikke isolering er valgt, vil hverken manuel isolering eller tvungen tilkobling kunne foretages. Valgmuligheder: Manuel isolering, Tvungen tilk. og Ikke isolering Bemærk! Tvungen tilkobling er ikke tilgængelig i SKAFOR versionen Genstart udgangsforsinkelse (fig. 4.4, lokation 09) Bemærk! Denne funktion er ikke tilgængelig i SKAFOR vers. Her bestemmer du, om udgangsforsinkelsen skal genstarte, hvis udgangs-/indgangsdøren åbnes igen før udgangsforsinkelsen udløber. Genstart af udgangsforsinkelsen er nyttig, hvis brugeren går ind efter en glemt genstand, straks efter at have forladt det afsikrede område. Tre valgmuligheder er tilgængelige: Genstart udg. udgangsforsinkelsen genstarter når døren åbnes under udgangsforsinkelsen. Genstarten sker kun én gang. Tid slut v/dør Når døren lukkes, slutter udgangsforsinkelsen automatisk (også selv om den definerede udgangsforsinkelse ikke er fuldt forløbet). Normal udg.tid Udgangsforsinkelsen forløber i sin fulde længde uanset om døren er åben eller lukket Ind/ud Bip (fig. 4.4, lokation 10) Her bestemmer du, om advarselsbip skal lyde under udgangs- og indgangsforsinkelse. En alternativ mulighed er at gøre buzzeren tavs, når systemet er Nat tilkoblet (HOME). De tre valgmuligheder er: Ud/ind bip til, Bip fra v/natt. og Ud/ind bip fra Problem bip (fig. 4.4, lokation 11) Ved konstatering af problemer, vil buzzeren afgive en serie af 3 korte bip, én gang i minuttet. Her afgør du, hvorvidt denne specielle bippe-sekvens skal være aktiv, ikke aktiv, eller kun være ikke aktiv om natten (længden af natten er fastsat fra fabrikkens side). De 3 valgmuligheder er: Problem bip til, Bip fra v/nat (fra kl til 07.00) og Bip fra Panik Alarm (fig. 4.4, lokation 12) Her bestemmer du, om brugeren skal have tilladelse til, at aktivere en panikalarm ved samtidig at trykke de to panik knapper (på centralens tastatur, eller det trådløse tastatur) eller Fuld Tilkobling + Nat Tilkobling tasterne på håndsenderen. Er zonen defineret med sirene, aktiveres denne, samtidig med at centralen sender alarmbesked via telefonen. Ved Tavs panik sender centralen kun besked via telefonen. Valgmulighederne er: Panikalarm tavs, Panikalarm sirene og Panikalarm fra Afbryd zone (fig. 4.4, lokation 13) Her bestemmer du hvor mange gange hver zone tillades at aktivere en alarm, indenfor en enkelt tilkoblingsperiode. (dette inkluderer sabotage & strømsvigtshændelser på detektorer, PowerMax+ og trådløs sirene). Hvis antallet af alarmer fra en specifik zone, overstiger det programmerede antal i denne lokation, vil alarmcentralen automatisk isolere zonen, for at undgå tilbagevenden sirenestøj og generende rapporteringer til kontrolcentralen. Zonen vil forblive isoleret indtil frakobling. Zonen vil blive reaktiveret ved frakobling, eller 48 timer efter at være blevet isoleret. (hvis systemet forbliver tilkoblet). Der er følgende valgmuligheder: Afbryd efter 1, Afbryd efter 2, Afbryd efter 3 og Afbryd ikke. Bemærk! Kun 1, 2 eller 3 gentilkoblinger er mulig i SKAFOR versionen Krydsene zoner (fig. 4.4, lokation 14) Her bestemmer du, om krydsende zoneinddeling skal være aktiv. Krydsende zoneinddeling er en metode til at modvirke falske alarmer en alarm vil ikke blive aktiveret medmindre 2 tilstødende zoner forstyrres indenfor en periode på 30 sekunder. Denne egenskab er kun aktiv, ved fuld tilkobling (AWAY) og kun ved zonepar fra zone nr. 18 til 27 (18 og 19, 20 og 21, etc.). Du kan anvende et hvilket som helst zonepar til, at etablere et krydsende zoneinddeling område. 12 DD5467IPP
25 Bemærk: Hvis en af to krydsende zoner er isoleret (se afsnit 4.8), vil den tilbageværende zone fungere uafhængig af den frakoblede. Bemærk: Zoner i Krydszone inddeling skal være af de tilladte typer: (Indvendig, Perimeter, Perimeter Flg.). Valgmulighederne er: Kryds zone Til og Kryds zone Fra. Krydsende zoneinddeling kan ikke anvendes ved Indgangs/udgangs zoner og 24T zoner (Brand, Nødkald, 24T sirene og 24T tavs) Overvågning (fig. 4.4, lokation 15) Her bestemmer du tidsintervallet for modtagelse af overvågningsrapport fra overvågede trådløse enheder. Hvis der ikke modtages overvågningsrapport fra en eller flere af de trådløse enheder, indenfor det i denne lokation valgte tidsinterval, vil PowerMax afgive en INAKTIVITET adviseringsrapport. Valgmulighederne er:1, 2, 4, 8, 12timer og Afbrudt. Bemærk! I SKAFOR godkendte installationer må overvågningstiden ikke overstige 4 timer IKKE KLAR (fig. 4.4, lokation 16) Her afgør du om systemet skal være i IKKE KLAR status når der er en overvågningsfejl. I "v/overvågning" vil systemet være i IKKE KLAR status hvis der i de sidste 20 minutter ikke er modtaget en overvågnings meddelelse. Valgmulighederne er: Normal og v/overvågning AUX Knap (fig. 4.4, lokation 17) Her vælger du funktion for funktionsknappen (AUX) på håndsenderen. Der er 3 valgmuligheder: Status: Tast på funktionsknappen (AUX) vil medføre, at alarmcentralen meddeler alarmsystemets status. Straks (Instant): Tast på funktionsknappen (AUX) mens udgangsforsinkelsen er i gang, vil medføre, at systemet foretager en Straks tilkobling (indgangsforsinkelsen bliver annulleret). PGM: Tast på funktionsknappen (AUX) vil aktivere PGM udgangen (se nærmere i OPSÆT UDGANGE i afsnit 7) RF-støj Det. (fig. 4.4, lokation 18) Her bestemmer du om RF-støj (forstyrrende transmission) på den radiokanal, som systemet anvender, vil blive detekteret og rapporteret. Hvis en forstyrrelse detekteres og RF-støj detektering er valgt, vil systemet ikke tillade tilkobling så længe der sker RF-støj jamming. RF-støj Detekterings muligheder Option Detektering og Rapportering når: UL (20/20) Der er 20 sekunders kontinuerlig RFstøj (USA standard) EN (30/60) Der er en akkumuleret 30 sekunders (Europa standard) RF-støj indenfor 60 sekunder. class 6 (30/60) Som EN (30/60) men hændelsen (Britisk standard) rapporteres kun hvis der er RF-støj i Afbrudt mere end 5 minutter. (ingen RF-støj detektering og rapport) Frakoblingsrapport (fig. 4.4, lokation 19) Her vælges om systemet skal kunne tilkobles med mulighed for modtagelse af Frakoblingsrapport. Hvis systemet tilkobles med denne mulighed, vil en Frakoblingsrapport blive sendt til specifikke telefoner når kode/håndsender holdere 5-8 frakobler centralen. Denne mulighed er anvendelig til bl.a. forældre der ønsker at blive informeret om at deres børn er kommet hjem fra skole. Der kan indtales et navn for hver håndsenderholder 5-8. Mulighederne er: Frakobl. Rap. Til og Frakobl. Rap. Fra Ikke Aktiv (fig. 4.4, lokation 20) Her bestemmer du tidsgrænsen, for modtagelse af signal fra en detektor, som anvendes til at overvåge aktiviteten fra syge, ældre eller handicappede personer. Hvis en indvendig detektor ikke detekterer og rapporterer bevægelse, mindst én gang indenfor den definerede tidsgrænse, vil en Ikke Aktiv advisering blive afgivet. Valgmuligheder: 3, 6, 12, 24, 48, 72timer og Ikke Aktiv Fra Baggrundslys (fig. 4.4, lokation 21) Her bestemmer du om baggrundslys på tastatur og Display altid skal være tændt, eller først tændes ved tastetryk og slukke automatisk efter 10 sekunder, efter sidste tastetryk. Valgmuligheder: Altid tændt og Sluk efter 10s Overfaldsalarm (fig. 4.4, lokation 22) Her bestemmer du om overfaldsalarmsfunktionen skal være aktiv eller ej. Der sendes en Overfaldsmeddelelse til kontrolcentralen hvis brugeren tvinges til at frakoble systemet. For at aktivere Overfaldsmeddelelsen, skal brugeren indtaste den specielle fabriksindstillede kode 2580 som er default. Koden kan ændres i denne menu, eller der kan indtastes "0000" for at afbryde denne funktion. Bemærk: Systemet giver ikke mulighed for at anvende denne kode som en almindelig brugerkode. Valgmuligheder: Overfald TIL og Overfald FRA Intern Sirene (fig. 4.4, lokation 23) Her bestemmer du om den indbyggede piezo sirene skal lyde under alarm. Spørg brugeren, om han ønsker denne alarm akustisk eller tavs. Valgmuligheder: Sirene til og Sirene fra Reset Menu (fig. 4.4, lokation 24) Her bestemmes det hvorledes systemet skal resættes efter en alarmhændelse. Valgmulighederne er: Bruger reset, Montør reset Bruger Reset efter alarm gøres automatisk af den daglige bruger af systemet, gennem frakoblingen efter alarmen, samt den næste tilkobling, hvor alarmen slettes fra hukommelsen. Hvis Montør reset er valgt, kan systemet kun resættes af en montør på en af tre mulige måder: 1. Ved at gå ind i, og ud af montørmenu. 2. Ved at gå ind i, og ud af hændelses log, (se afsnit 12). 3. Med kommandoer via telefon. For at udføre en Montør reset via telefon etableres der kommunikation med PowerMax+ (se bruger guide, afsnit 6.3A, trin 1-5) og fortsæt som følger: a. [*], [montør kode], [#] b. Vent på at høre 2 bip c. [*], [1], [#] d. [*], [99], [#] Sabotage rapport (fig. 4.4, lokation 25) Her vælges om zone sabotage skal rapporteres eller ignoreres. Valgmulighederne er: Sabot. Rap. til og Sabot. Rap. Fra. DD5467IP 13
26 Sirene v/fejl (fig. 4.4, lokation 26) Her bestemmes det om sirenen skal aktiveres hvis der opstår en telefonliniefejl medens systemet er tilkoblet. Valgmulighederne er: V/tlf. Fejl Til og V/tlf. Fejl Fra Alarm indikering (fig. 4.4, lokation 27) Her bestemmes det om brugeren vil få en indikering om at en alarm er aktiveret. Valgmulighederne er: Indikering til og Indikering fra Frakobl menu (fig. 4.4, lokation 28) Her angives det hvornår det er muligt at frakoble systemet: A. Altid. B. Under indgangsforsinkelse, enten ved anvendelse af PowerMax+ tastatur eller med håndsender. C. Under indgangsforsinkelse, men kun ved anvendelse af håndsender. D. Under indgangsforsinkelse, men kun ved anvendelse af PowerMax+ tastatur, med PowerMax+ i Tilkoblet (AWAY) status. Valgmuligheder: Altid, Ved indg. begge, Ved indg. m/hånds., eller Ved indg. m/tast Jam rapport (fig. 4.4, lokation 29) Her vælges det, om der skal aktiveres en alarm med sirene og rapportering, hvis der er en overvågnings/ jamming fejl medens systemet er tilkoblet. Valgmulighederne er: EN standard og andet. Hvis "EN standard" er valgt, og der er en overvågnings/jamming fejl i tilkoblet status, vil sirenen blive aktiveret og hændelsen vil blive rapporteret som en sabotage hændelse til kontrolcentralen. Hvis andet er valgt, vil hændelsen ikke aktivere sirene og ikke generere en rapport Hånds. Batteri (fig. 4.4, lokation 30) Her vælges det om brugeren skal kvittere for meddelelse om lavt batteri i håndsender ved frakobling af system. Mulighederne er: Kvittering til (brugeren skal kvittere for lavt batteri meddelelsen) eller Kvittering fra (brugeren skal ikke kvittere). Ved Kvittering til sker følgende ved lavt batteri i håndsender: Centralen vil afgive et lavt problem bip i 15 sekunder ved frakobling af centralen med håndsenderen, som tegn på, at håndsenderens batteri er svagt. Brugeren skal nu igen trykke frakobling på håndsenderen, eller trykke HOME og brugerkode på centralen, for at frakoble centralen. Udføres kvittering inden for de 15 sekunder, vil svagt batteri hændelsen gemmes i loggen. Hvis frakobling ikke udførtes igen inden for de 15 sekunder, gør da et af følgende: A: Hvis der ønskes Tilkobling: Tryk AWAY to gange for at tilkoble system, ellers vil centralen ikke tilkobles og kvitteringen vil ikke gemmes i loggen. B: Hvis der ønskes frakobling: Tryk AWAY og derefter HOME for at kvittere for svagt batteri meddelelsen Screen Saver (fig. 4.4, lokation 31) Her kan det vælges om displayet i centralen, efter 30 sekunder hvor der ikke er trykket på nogen tast, skal indsætte navnet PowerMax som screen saver, og samtidig slukke for indikerings LED erne (for at forhindre en eventuel indbrudstyv i at se systemets status). Det kan vælges om normalt display og LED visning skal retableres efter tryk på en hvilken som helst tast (Opdater ved tast), eller om det skal gøres ved at taste OFF knappen efterfulgt af bruger koden. (Opdater ved kode). Hvis Opdater ved tast er valgt, vil den første tast der røres (undtaget Brand og Nødkald) opdatere displayet og næste tryk vil udføre tastens funktion. Brand og Nødkalds tasterne vil ved første tryk, både retablere almindelig visning OG udføre tasternes funktion. Valgmulighederne er: Screen Saver fra, Opdater ved kode eller Opdater ved tast Bekræftet alarmtid (fig. 4.4, lokation 32) Her bestemmes den tid indenfor hvilken, to på hinanden følgende alarmer vil udløse en Bekræftet alarm. (for rapportering af Bekræftet alarm, se afsnit BKRFT. ALM. RAP.) Valgmulighederne er: Ikke anvendt, 30min., 45min., 60min., eller 90min Strømsvigt rapport (fig. 4.4, lokation 33) Her bestemmes den tid fra hvilken der detekteres at der er strømsvigt, til dette faktisk rapporteres til kontrolstationen. Valgmulighederne er: 5min., 30min., 60min. eller 180min Bruger tilladelse (fig 4, lokation 35) Her angives det om adgang til MONTØR MENU kræver brugertilladelse. Hvis du vælger AKTIVERET, er Montør menuen kun tilgængelig efter indtastning af bruger kode. Vælg mellem: AKTIVERET og IKKE AKTIVERET. 14 DD5467IPP
27 KLAR 00:00 NORMAL MENU BRUGER MENU MONTØR MENU INDTAST KODE: [Montør kode] 1. NY MONTØR KODE 2. INDLÆSNING 3. OPSÆT ZONER 4. OPSÆT CENTRAL 5.OPSÆT KOMM. 6. OPSÆT GSM 7.OPSÆT UDGANGE 8.OPTAG TALE 9.TILSTANDSTEST 10.BRUGEROPSÆTN. 11.FABRIKSOPSÆTN 12. SERIENUMMER 13. START UL/DL <> FOR AFSLUT Bemærk: Den i øjeblikket valgte parameterværdi er vist med en mørk boks i højre side. Hvis du ønsker at vælge en anden værdi, kan du gense de andre muligheder ved at taste eller BACK gentagne gange. Vælg den ønskede værdi ved tryk på knappen. En mørk boks i højre side markerer valget. 01: IND.FORS. 1 Ind.Fors.1 00 s Ind.Fors.1 15 s Ind.Fors.1 30 s Ind.Fors.1 45 s Ind.Fors.1 60 s Ind.Fors.1 3 m Ind.Fors.1 4 m 05: FORS.ALARM fors.alarm 00 s fors.alarm 15 s fors.alarm 30 s fors.alarm 45 s fors.alarm 60 s fors.alarm 2 m fors.alarm 3 m fors.alarm 4 m 02: IND.FORS. 2 03: UDG.FORS. 04: SIRENE TID Ind.Fors.2 00 s Udg.Fors. 30 s sirene tid 1 m Ind.Fors.2 15 s Udg.Fors. 60 s sirene tid 3 m Ind.Fors.2 30 s Udg.Fors. 90 s sirene tid 4 m Ind.Fors.2 45 s Udg.Fors. 120 s sirene tid 8 m Ind.Fors.2 60 s Udg.Fors. 3 m sirene tid 10 m Ind.Fors.2 3 m Udg.Fors. 4 m sirene tid 15 m sirene tid 20 m Ind.Fors.2 4 m 06: ALARM ANNL. 07: HURTIG TILK. FRA 08: ISOLERET alarm annl. 1 m hurtig tilk. TIL man. isolering alarm annl. 5 m hurtig tilk. FRA ingen isolering alarm annl. 15 m tvungen tilk. alarm annl. 60 m alarm annl. 4 h ingen annuller. 09: GENSTART UDG. 10: IND/UD BIP 11: PROBLEM BIP 12: PANIKALARM genst. udg. tid ud/ind bip til problem bip til panikalarm tavs tid slut v/dør bip fra v/natt. problem bip fra panikalm sirene normal udg. tid ud/ind bip fra bip fra v/nat panikalarm fra 13: AFBRYD ZONE 14: KRYDS ZONER 15: OVERVÅGNING 16: IKKE KLAR afbryd efter 1 kryds zone TIL overv. tid 1 t normal afbryd efter 2 kryds zone FRA overv. tid 2 t v/overvågning afbryd efter 3 overv. tid 4 t afbryd ikke overv. tid 8 t overv. tid 12 t afbrudt 17: AUX KNAP 18: RF-STØJ DET. 19: FRAK. RAPPORT 20: IKKE AKTIV system status UL (20/20) frakob.rap. TIL ikke aktiv 3 t straks tilk. EN (30/60) frakob.rap. FRA ikke aktiv 6 t PGM / X-10 AKTV. class 6 (30/60) ikke aktiv 12 t afbrudt ikke aktiv 24 t ikke aktiv 48 t ikke aktiv 72 t ikke aktiv fra 21: BAGGRUNDSLYS 22: OVERFALD 23:INTERN SIRENE 24: RESET MENU altid tændt Overfaldskode 2580 sirene TIL bruger reset sluk efter 10s (Indtast ny kode eller sirene FRA montør reset 0000 for at slå funktionen fra.) 25: SABOTAGE MENU 26: SIRENE V/FEJL 27: ALARM I HUK. 28:FRAKOBL MENU sabot. rap. til v/tlf.fejl fra indikering til altid begge sabot. rap. fra v/tlf.fejl til indikering fra indg.m/begge indg.m/hånds. indg.m/tast. 29: JAM RAPPORT 30: HÅNDS.BATTERI 31: SCREEN SAVER 32:BEKRF.ALM.TID EN standard kvittering til scrn saver FRA opdater v/tast andet alm før 30 kvittering fra kvittering fra opdater v/tast alm før 45 alm før 60 alm før 90 33: STRØMSV.RAP. 35: BRUGER TILL. efter 5min Ikke Aktiveret efter 30min Aktiveret efter 60min efter 180min Figur 4.4 OPSÆT CENTRAL, oversigt DD5467IP 15
28 4.5 OPSÆTNING AF KOMMUNIKATIONSPARAMETRE Indledende vejledning Denne menu giver mulighed for at opsætte og tilrette telefon kommunikation parametrene til de lokale krav og betingelser. Kompatible Kontrolcentral modtagere er: Osborne-Hoffman, model Ademco, Model 685. FBII, model CP220. Radionics, model D6500. SurGard, model SG-MLR2-DG og Silent Knight, model VIGTIGT: I telefon/personsøger nummerlokationer, kan du få behov for at indtaste hexadecimale cifre. I telefon nummerlokationer, bruges disse cifre som koder til at styre modemet: Hex. Indtastning Kodens betydning. Ciffer sekvens A <#> <0> Koden anvendes kun som først kode i nummeret - Modemet venter 10 sekunder eller venter for klartone (afhængig af hvad der kommer først) og foretager derefter opkaldet. B <#> <1> Indsætter stjernetegn (*) C <#> <2> Indsætter nummertegn (#) D <#> <3> Koden anvendes kun som først kode i nummeret - Modemet venter 5 sekunder på klartone og lægger på, hvis denne ikke modtages E <#> <4> Koden anvendes kun som først kode i nummeret - Modemet venter 5 sekunder F <#> <5> Ikke anvendelig i telefonnumre. Ved indtastning af en række cifre, er følgende taster nyttige: <Nummer taster> - for at indtaste nummeret - flytter markøren fra venstre mod højre. - flytter markøren fra højre mod venstre. - slet alt efter markøren (til højre) Tlf. Test tid (fig. 4.5, lokation 01) Her bestemmes tiden ved hvilken telefonlinien vil blive testet, og rapporteret til kontrolcentralen Tlf. test repetition (fig. 4.5, lokation 02) Her angives tidsintervallet mellem hver telefonlinie test og meddelelse til kontrolcentralen. PowerMax+ centralen foretager denne test med jævne mellemrum, for at sikre fejlfri kommunikation. Valgmulighederne er: Test hver 1, 5, 7, 30 dage og Ingen test Områdenummer (fig. 4.5, lokation 03) Her kan indtastes et områdenummer for telefon forbindelsen. (op til 4 cifre) Bylinie Nr. (fig. 4.5, lokation 04) Hvis systemet er koblet til en intern telefoncentral, kan her indtastes det nummer der sædvanligvis vil give adgang til en bylinie kontrolcentral tlf. (fig. 4.5, lok. 05) Her indtastes telefonnummer (inkl. områdenummer, max 16 cifre) på den primære kontrolcentral som alarmer rapporteres til, i henhold til opsætningen i lokation 11 (se note i fig. 4.5) kontonr. (fig. 4.5, lokation 06) Her indtastes kontonummeret der vil identificere PowerMax+ alarmcentralen til den primære kontrolcentral. Nummeret består af 4 eller 6 hexadecimale cifre (se note i fig. 4.5) Kontrolcentral tlf. (fig. 4.5, lok. 07) Her indtastes telefonnummer (inkl. områdenummer, max 16 cifre) på den sekundære kontrolcentral som alarmer rapporteres til, i henhold til opsætningen i lokation 11 (se note i fig. 4.5) kontonr. lokation 08) Her indtastes kontonummeret der vil identificere PowerMax+ alarmcentralen til den sekundære kontrolcentral. Nummeret består af 4 eller 6 hexadecimale cifre (se note i fig. 4.5) Rapport Format (fig. 4.5, lokation 09) Her vælges det rapport format PowerMax+ skal anvende for at kunne rapportere hændelser til den kontrolcentral der abonneres på. (se note - fig. 4.5). Mulige rapportformater er: Contact-ID SIA 4/2 1900/1400 4/2 1800/2300 Scancom (se Appendiks C - kode liste) /2 Pulshastighed (fig. 4.5, lokation 10) Her vælges pulshastigheden med hvilken data sendes til kontrolcentralen hvis en af de to 4/2 formater er valgt i Lokation 09, Rapport format. (se note i fig. 4.5). Valgmulighederne er: 10, 20, 33 og 40pps Rap. til kontrolcentral (fig. 4.5, lokation 11) (se note i fig. 4.5). Her bestemmer du hvilke typer af hændelser, der skal rapporteres til kontrolcentralen. På grund af pladsmangel i displayet, anvendes følgende forkortelser: alarm er ALM, advisering er ADV og frakoblet/tilkoblet er F/T. Stjernetegn (*) adskiller de hændelser der rapporteres til kontrolcentral 1 og de hændelser der rapporteres til kontrolcentral 2. Meddelelser deles op i tre grupper: GRUPPE HÆNDELSE RAPPORTERET Alarmer Brand, indbrud, panik og sabotage Fra/til Fuld tilkobling, Nat tilkobling, Frakobling Advisering Ikke-aktiv, Nødkald, Frakoblingsrapport Alarm-gruppen har den højeste prioritet og Adviseringsgruppen har den laveste prioritet. De forskellige valgmuligheder angives i følgende tabel: Navn i display Sendes til kontrol-central 1 Sendes til kontrolcentral 2 ALT * BACKUP Alle hændelser Samme, hvis ikke kontrolcentral 1 svarer ALT F/T * BACKUP Alle hændelser undtagen fra/til Samme, hvis ikke kontrolcentral 1 svarer ALT * ALT Alle hændelser Alle hændelser ALT F/T * ALT F/T Alle hændelser undtagen fra/til Alle hændelser undtagen fra/til ALT F/T * F/T Alle hændelser Alene fra/til undtagen fra/til ALT ADV * ADV Alle hændelser Advisering undtagen advis. ALM * ALT ALM Alarmer Alle hændelser undtagen alarmer AFBRUDT Intet Intet Bemærk: ALT betyder, at alle 3 grupper bliver rapporteret ligesom også problemmeddelelser rapporteres svagt batteri i detektor/system, detektor inaktiv, strømsvigt, RF-støj og kommunikationsfejl. 16 DD5467IPP
29 Bekrft. Alarm rapport (fig. 4.5, lokation 12) Her vælges det om systemet skal rapportere en Bekræftet alarm hvis 2 eller flere alarmhændelser optræder indenfor en valgt tidsperiode. (se afsnit 4.32). (se note i fig. 4.5). Valgmuligheder: Rapport til, Rapport fra, Rapp.+Isoler. (Rapportering og isolering af detektor hvor PowerMax+ er kompatibel med DD423 standard) Send 2VT kode (fig. 4.5, lokation 13) Her vælges det om PowerMax+ i forbindelse med kommunikation med kontrolcentralen skal tillades at sende 2-vejs tale kode til kontrolcentralen, (for at skifte kommunikationsstatus fra data til tale) ved anvendelse af forud defineret SIA eller Contact-ID kommunikationsformat. (se note i fig. 4.5). Valgmulighederne er: Sendes og Sendes ikke vejs tale med kontrolcentral (fig. 4.5, lokation 14). (se note i fig. 4.5). Her vælges den maksimalt tilladte taletid for 2-vejs tale kommunikation med Kontrolcentralen. Alternativt om kontrolcentralen skal ringe tilbage til PowerMax+ for opnåelse af 2-vejs tale funktionen. Denne mulighed er kun anvendelig efter rapportering af en hændelse til kontrolcentralen. (Vagten på kontrolcentralen kan trykke [3] på telefonen for at lytte, [1] for at tale og [6] for at lytte og tale). Valgmulighederne er: Afbryd efter 10, 45, 60, 90 sek eller 2min, V/tilbagekald og Afbrudt (ingen 2-vejs tale kommunikation tilladt). Bemærk: Hvis Tilbagekald er valgt, bør der også vælges "Ingen Rapport" til private telefoner (se afsnit Rapportering til Privat Telefon), ellers vil kontrolcentralen oprette kommunikation til PowerMax+ (efter en hændelse) på normal vis (og ikke efter en ringetone) Tilbagekaldstid (fig. 4.5, lokation 15) Her vælges den tid, inden for hvilken, kontrolcentralen kan oprette 2-vejs tale kommunikation med PowerMax+, straks efter 1 ring (i modsætning til normal procedure), under forudsætning af at: A. Alarm hændelsesrapport blev modtaget af kontrolcentralen, og B. Tilbagekald er valgt under afsnit Valgmulighederne er: 1, 3, 5 eller 10min (se note i fig. 4.5) Opkaldsforsøg til KC (fig.5, lokation 16) Her vælges det maksimale antal gange PowerMax+ skal forsøge at ringe til kontrolcentralen. (se note i fig. 4.5). Valgmulighederne er: 2, 4, 8, 12, eller 16 forsøg Privat Tlf. Nr. (fig. 4.5, lokation 17) I dette menupunkt kan indtastes op til fire private telefon numre (inkl. områdenummer) til hvilke det ønskes at systemet vil rapportere de hændelser der er definerede i Lokation vejs tale med privat telefon (fig. 4.5, lokation 18) Her vælges det om 2-vejs tale kommunikation med private telefoner skal være tilladt. De to muligheder er: Tale Til og Tale Fra Opkaldsforsøg privat telefon (fig. 4.5, lokation 19) Her angives det maksimale antal gange PowerMax+ skal forsøge at ringe til et privat telefonnummer. Valgmulighederne er: 1, 2, 3 og 4 forsøg Rapportering til privat telefon (fig. 4.5, lokation 20) Her bestemmes det hvilke hændelsesgrupper der skal rapporteres til private telefoner. Mulighederne er vist i nedenstående skema: Hændelsesgr. Beskrivelse ALT Alle hændelser ALT (-F/T) All hændelser, undtaget fra/til ALT (-ADV) All hændelser, undtaget advisering ALARM Alarm hændelser ADV Adviserings hændelser FRA/TIL Fra og Tilkobling INGEN RAPPORT Ingen hændelser rapporteres Bemærk: ALT inkluderer også Svagt Bat. og Strømsvigt hændelser Tlf. bekræftelse (fig. 4.5, lokation 21) Her bestemmes det om PowerMax+ skal anvende En bekræfter eller Alle bekræfter procedure ved rapportering af hændelser til private telefoner. Bemærk: Ved En bekræfter procedure, vil bekræftelse på modtagelse af rapportering fra blot en af de private telefoner være tilstrækkeligt, for at betragte den aktuelle hændelse for afsluttet, og stoppe videre kommunikations forsøg. De resterende telefoner er alene backup. Ved Alle bekræfter procedure, SKAL en bekræftelse fra alle private telefoner indlagt i systemet modtages, før den aktuelle hændelse betragtes som behørigt rapporteret. De to muligheder er: En bekræfter og Alle bekræfter Pager Tlf. Nr. (fig. 4.5, lokation 22) Her indtastes telefonnummer (inkl. Områdenr.) på den Pager (personsøger), som PowerMax+ skal rapportere til Pager PIN Nr. (fig. 4.5, lokation 23) Her indtastes personsøgerens PIN kode en digital sekvens, som fungerer som personsøgerens adresse. Personsøger udbyderens computer har brug for nogle informationer for, at lede en meddelelse direkte til en specifik personsøger. PIN sekvensen går forud for den digitale meddelelse, som PowerMax+ sender til personsøgeren for at rapportere en hændelse. Den kan indeholde cifre, mellemrum og specielle tegn ( eller #). Kontakt personsøger udbyderen for, at få informationer om hvad personsøgerens PIN kode består af. Vigtigt! I denne lokation, kan de specielle karakterer indtastes således: For at indsætte Indtastnings sekvens Displayet viser <#> <1> B # <#> <2> C 5 sek pause <#> <3> E Indtast personsøgerens PIN kode (op til 16 cifre, inkl. Specielle tegn, afhængig af personsøgerens protokol) Rapport til Pager (fig. 4.5, lokation 24) Her bestemmes det hvilke hændelsesgrupper der skal rapporteres til pager (personsøger). (forkortelser er som anvendt i afsnit 5.11). Rapporteringsmuligheder er: ALT ALARM + ADV ALT (- F/T) ADV + F/T ADV F/T INGEN RAPPORT DD5467IP 17
30 KLAR 00:00 NORMAL MENU BRUGER MENU MONTØR MENU INDTAST KODE: [Montør kode] 1. NY MONTØR KODE 2. INDLÆSNING 3. OPSÆT ZONER 4. OPSÆT CENTRAL 5. OPSÆT KOMM. 6. OPSÆT GSM <> FOR AFSLUT Bemærk For PowerMax+ der har både Montør kode og Master kode, er følgende funktioner kun tilgængelige ved brug af Master kode: 05:1.KONTR.C.TLF 06:1.KONTONR. 07:2.KONTR.C.TLF 08:2.KONTONR. 09:RAPP. FORMAT 10:4/2 PULSHAST. 11:RAP. KONTR.C. 11:RAP. ARC 12:BEKRF.ALM.RAP 13:SEND 2VT KODE 14:TALE KONT.C. 15:TILB.KALDSTID 16:OPK.FORS.K.C. 27:DOWNLOAD KODE 01:TLF.TEST TID 02:TLF.TST REP. 03:OMRÅDE NR. 04:BYLINIE NR. Test tid 12:00 test hver 1d xxxx x test hver 5d (Indtast test tid) test hver 7d (Indtast områdenr. (Indtast nr. for bylinie test hver 14d Op til 4 cifre) adgang, 1 ciffer) test hver 30d ingen test (se Bemærk) (se Bemærk) (se Bemærk) (se Bemærk) 05:1.KONTR.C.TLF 06:1.KONTONR. 07:2.KONTR.C.TLF 08:2.KONTONR. xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxx (Indtast tlf. nr.) (Indtast kontonr.) (Indtast tlf. nr.) (Indtast kontonr.) (se Bemærk) (se Bemærk) (se Bemærk) (se Bemærk) 09:RAPP. FORMAT 10:4/2 PULSHAST. 11:RAP. KONTR.C. 12:BEKRF.ALM.RAP contact ID 10 pps alt - f/t * backup SIA 20 pps alt * 4/2 1900/ pps alt rapport til rapport fra alt - f/t * all - f/t rapp.+isoler. 4/2 1800/ pps alt - f/t * f/t Scancom alt (-alrt) * alrt alm * alt (-alm) Se appendiks kode liste afbrudt alt * backup (se Bemærk) (se Bemærk) (se Bemærk) (se Bemærk) 13:SEND 2VT KODE 14:TALE KONT.C. 15:TILB.KALDSTID 16:OPK.FORS.K.C. sendes afbr. efter 10 s før 1 m max 2 forsøg sendes ikke afbr. efter 45 s før 3 m max 4 forsøg afbr. efter 60 s før 5 m max 8 forsøg afbr. efter 90 s før 10 m max 12 forsøg afbr. efter 2 m max 16 forsøg v/tilbagekald afbrudt 17:PRIVAT TLF.NR 18:TALE PRV.TLF 19:OPK.FORS.PRVT 20:RAP. PRIV.TLF 1. priv. tlf.# tale til max 1 forsøg 2. priv. tlf.# tale fra max 2 forsøg 3. priv. tlf.# max 3 forsøg 4. priv. tlf.# xxxxxxxxxxxxxxxx Indtast tlf. nr. max 4 forsøg alt alt (-f/t) alt (-prbl) alarm problem fra/til ingen rapport 21: TLF.BEKRÆFT 22:PAGER TLFNR. 23:PAGER PIN NR. 24:RAPPORT PAGER 25:NYLIG TILK. en bekræfter xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx alt nylig tilk. til alle bekræfter alarm + prbl (Indtast tlf. nr.) (Indtast kontonr.) alt (-f/t) nylig tilk. fra prbl + f/t trbl problem ingen rapport (se Bemærk) 26:FJERNBTJ.ADG. 27:DOWNLOAD KODE 28:MONT. DL.KODE 29: CENTRAL ID 30: ZONE RESET + adg. tilladt downl. code AAAA downl. code BBBB Unit ID xxxx xxxx reset rap. til adg. ikke till. reset rap. fra (Indtast 4 cifret kode (Indtast 4 cifret kode er ikke tilladt) 0000 er ikke tilladt) 31: UPLOAD VALG 32:OPKALDSMETODE 33:TLF.FEJL RAP. 34: UL/DL TLF # 35: SYS INAKT RAP i frakobling dtmf toner ingen rapport xxxxxxxxxxxxxxxx ingen rapport altid puls rapport straks rap efter 7d Indtast tlf. nr. rap. efter 5m rap efter 14d rap. efter 30m rap efter 30d rap. efter 60m rap efter 90d 36: MODRING KODE rap. efter 180m xxxxxx (Indtast 6-cifret kode) Figur 4.5 OPSÆT KOMMUNIKATION oversigt 18 DD5467IP
31 Nylig tilkobling (fig. 4.5, lokation 25) Her bestemmes det, om en Nylig tilkobling rapport skal sendes til kontrolcentralen, hvis en alarmhændelse sker indenfor 2 minutter fra udløbet af udgangsforsinkelsen. Valgmulighederne er: Nylig tilk. Til og Nylig tilk. Fra Fjernbetj. Adg. (fig. 4.5, lokation 26) Her angives det, om der skal gives adgang til at kunne styre PowerMax+ centralen fra en telefon. Valgmulighederne er: Adgang tilladt og Adg. ikke till Master Download kode (fig. 4.5, lokation 27) Her indtastes det 4-cifrede password, der skal bruges ved download af data ind i PowerMax+ hukommelsen. (se note i fig. 4.5). Advarsel! Anvend ikke 0000 denne kode er ikke gyldig Montør Download kode (fig. 4.5, lokation 28) Her indtastes det 4-cifrede password, der skal bruges ved download af data ind i PowerMax+ hukommelsen. (se note i fig. 4.5). Advarsel! Anvend ikke 0000 denne kode er ikke gyldig Central ID (fig. 4.5, lokation 29) (For fremtidigt brug En identifikationskode for et PowerMax+ system, der er forbundet med andre systemer i et netværk) Zone Reset (fig. 4.5, lokation 30) Her bestemmes det om zone reset er en hændelse der skal rapporteres. Valgmulighederne er: Reset rap. Til og Reset rap. Fra OPSÆT GSM PARAMETRE Denne menu er kun relevant hvis PowerMax+ er forbundet til en GSM enhed. I denne menu kan der foretages følgende opsætninger: 1. Vælge om GSM enheden er installeret / ikke installeret. 2. Indtaste 4 private SMS telefonnumre til hvilke hændelser skal rapporteres. 3. vælge hvilke typer af hændelser der skal rapporteres til SMS telefonnumrene. 4. Vælge om GSM enheden skal fungere som backup for den ordinære telefonlinje, som den primære telefonforbindelse (med den ordinære som backup), som den eneste telefonforbindelse, eller udelukkende som SMS kommunikationskanal. 5. Vælge om manglende GSM forbindelse til netværk skal rapporteres efter 2, 5, 15 eller 30min, eller ikke rapporteres. Opsætningsforløbet er illustreret i figur 4.6. I denne illustration, er de valgte muligheder angivet med en mørk boks i højre side. Hvis en anden værdi ønskes, kan man gense de andre muligheder ved at taste <> eller <BACK> gentagne gange. De muligheder, som ikke aktuelt er valgt har en ledig plads. Vælg den ønskede værdi ved tryk på VIS/ knappen. En mørk boks i højre side markerer valget GSM Installeret Her angives det om GSM enheden er fysisk installeret, og forbundet til PowerMax+ med det medfølgende special kabel. Valgmulighederne er: GSM installeret og GSM ikke instal Upload Valg (fig. 4.5, lokation 31) Her vælges det om PowerMax+ data kun kan uploades til en computer medens systemet er i frakoblet tilstand, eller om dette kan ske altid (i Tilkoblet, Nat tilkoblet og frakoblet). Valgmulighederne er: I frakobling og Altid Opkaldsmetode (fig. 4.5, lokation 32) Her vælges det hvilken opkaldsmetode der skal bruges af det indbyggede modem i PowerMax+ centralen. Valgmulighederne er: Puls og DTMF toner Tlf. fejl rap. (fig. 4.5, lokation 33) Her vælges det inden for hvilket tidsrum efter en detekteret telefonlinjefejl, at denne fejl skal rapporteres. Hvis telefonlinjen er afbrudt, vil hændelsen "tlf. linje fejl" blive gemt i hændelsesloggen. Valgmulighederne er: Ingen rapport, Rapport straks, Rap. efter 5m, Rap. efter 30m, Rap. efter 60m eller Rap. efter 180m UL/DL Tel. Number (fig. 4.5, lokation 34) Her indtastes telefonnummeret (op til 16 cifre) på UL/DL serveren (Upload/Download) System Inaktivitets Rapport (fig. 4.5, lokation 35) Her bestemmes det om Kontrol stationen skal modtage en meddelelse hvis systemet er inaktivt (ikke bliver tilkoblet) i en angivet periode (dage). Valgmulighederne er: Ingen rapport, rap. efter 7d, rap. efter 14d, rap. efter 30d, rap. efter 90d Modopkalds kode (fig. 4.5, lokation 36) Her indtastes en 6-cifret kode der anvendes af Kontrolstationen til at aktivere tilbageringning til systemet SMS telefonnumrene 1-4 I denne menu indtastes hvert af de fire mulige SMS telefonnumre (inkl. områdenummer, max 16 cifre) til hvilke de udvalgte hændelsestyper skal rapporteres (se næste afsnit) Rapport til SMS Her vælges det hvilke typer af hændelser der ønskes rapporteret til de fire mulige SMS telefonnumre. Hændelser er opdelt i tre grupper, i følgende prioriterede rækkefølge: GRUPPE HÆNDELSES RAPPORT Alarmer Brand, Indbrud, Panik, Sabotage Til/Fra Tilkobling, Nat tilkobling, frakobling Advisering Ingen aktivitet, Nødkald, Frakobl. rapport Valgmulighederne er vist i nedenstående skema: Hændelsestype Beskrivelse Alt Alle hændelsestyper alt (-til/fra) Alle hændelsestyper, undtaget til/fra alt (-advis) Alle hændelsestyper, undtaget Advis. Alarmer Alarmer Advisering Advisering Til/fra Til/fra Disable report Ingen rapportering Bemærk: Alle betyder at, ud over de tre hændelsesgrupper, rapporteres også problemmeddelelser som detektor/system svagt batteri, detektor inaktivitet, strømsvigt, RF-støj, kommunikationsfejl etc. DD5467IP 19
32 4.6.4 GSM Netforbindelse rapport Her bestemmes det hvor hurtigt en manglende GSM netværksforbindelse skal rapporteres. Valgmulighederne er: Ingen rapport, Rap. efter 2m, Rap. efter 5m, Rap. efter 15m, eller Rap. efter 30m. KLAR 00:00 NORMAL MENU BRUGER MENU MONTØR MENU INDTAST KODE [Montør kode] 1. NY MONTØR KODE 2. INDLÆSNING 3. OPSÆT ZONER 4. OPSÆT CENTRAL 5. OPSÆT KOMM. 6. OPSÆT GSM 7.OPSÆT UDGANGE <> FOR AFSLUT GSM formål Her angives formålet med GSM netværksforbindelsen. GSM enheden kan fungere som backup for den ordinære telefonlinje, som den primære telefonforbindelse (med den ordinære som backup), som den eneste telefonforbindelse, eller udelukkende som SMS kommunikationskanal. Valgmulighederne er: GSM er backup, GSM er primær, GSM er eneste eller Kun SMS. GSM INSTALL. 1. SMS nummer 2. SMS nummer 3. SMS nummer gsm installeret xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx gsm ikke instal (Indtast GSM nr.) (Indtast GSM nr.) (Indtast GSM nr.) 4. SMS nummer REPORT TIL SMS RAP. V/GSM FEJL GSM FORMÅL xxxxxxxxxxxxxxxx ingen rapport ingen rapport KUN SMS (Indtast GSM nr.) alt rap. efter 2m GSM er backup alt (-f/t) rap. efter 5m GSM er primær alt -prbl rap. efter 15m GSM er eneste alarm rap. efter 30m problem fra/til Figur 4.6 OPSÆT GSM 4.7. OPSÆT UDGANGSPARAMETRE Indledende vejledning Denne menu giver mulighed for at: a. Vælge hvilke hændelser og betingelser for hvilke PGM (programmerbar) udgang og op til 15 X-10 enheder skal fungere. b. Vælge funktion for hver X-10 enhed samt PGM udgangen. c. Generel opsætning af X-10 enheders parametre. d. Vælge mellem intern sirene eller STROBE lys (som aktiveres i henhold til systemopsætningen). e. Indlæse 2-vejs X-10 enheder. Opsætningsforløbet er vist i Fig I denne illustration, er de valgte muligheder angivet med en mørk boks i højre side. Hvis en anden værdi ønskes, kan man gense de andre muligheder ved at taste <> eller <BACK> gentagne gange. De muligheder, som ikke aktuelt er valgt har en ledig plads. Vælg den ønskede værdi ved tryk på VIS/ knappen. En mørk boks i højre side markerer valget Opsæt PGM Her bestemmes det hvilke faktorer, som skal aktivere PGM udgangen. De forskellige muligheder er: V/TILKOBLING: Aktiveres ved tilkobling og afbrydes ved frakobling. V/NAT TILKOB.: Aktiveres Ved Nat tilkobling og afbrydes ved frakobling. V/FRAKOBLING: Aktiveres ved frakobling. 20 DD5467IP V/ALARM: Pulsering TIL/FRA under registrering af en alarm i hukommelsen; konstant TIL efter Frakobling og FRA ved sletning af hukommelsesindikationen. V/FORSINK.: Aktiveres under indgangs- og udgangsforsinkelser. TIL V/HÅNDSEND: aktiveres ved, at taste funktionsknappen (AUX) på håndsender eller fjernbetjening MCM-140 under forudsætning af, at PGM/X-10 er valgt i lokation 17 i Opsæt Central menuen. V/ZONER: aktiveres ved forstyrrelse i 3 valgfrie zoner, uafhængig af om systemet er til- eller frakoblet. Hvis der vælges Toggle, vil PGM udgangen blive tændt ved en hændelse i disse zoner, og vil blive slukket ved den næste hændelse, skiftevis. V/LINIEFEJL: PGM udgangen er tændt, hvis telefonlinien er afbrudt. Bemærk: PGM udgangen kan programmeres til at blive aktiveret af enhver kombination af de anførte faktorer Opsæt INT udgang Her vælges det om INT udgangen skal bruges til en Indvendig sirene eller til et Strobe lys Opsæt X-10 Funktioner For X-10 enheder, kan følgende generelle funktioner opsættes: Blink ved alarm. I denne menu vælges det om X-10 enhederne skal blinke ved en alarm. Man kan vælge mellem Alle blinker eller Ingen blinker. LED V/X-10 Fejl. Her kan det vælges om Problem LED en på centralen skal lyse ved en X-10 fejl. Vælg mellem: LED tændt eller LED ikke tændt for X-10 fejl.
33 Fejl rapport. Denne menu har 5 undermenuer, en for hver rapporteringsmulighed. Det kan vælges om der skal rapporteres, eller ikke rapporteres til: Kontrolcentral 1, Kontrolcentral 2, Pager, Private telefoner og sendes SMS, ved fejl i en X-10 enhed. 3Faser & Frekv. I forbindelse med X-10 signal transmission skal der vælges netfrekvens, samt om man ønsker transmission på tre faser. Vælg mellem: 3Faser 50Hz, 3Faser 60Hz eller Ikke 3Faser, for at opsætte X- 10 signal transmissionstype. Sluk-Lys-Tid. Her indtastes start og slut klokkeslæt for den periode for hvilken PGM skal være slukket, uafhængig af øvrige indstillinger eller kommandoer. Sluk-lys-tid har prioritet forud for andre timeraktiveringer for PGM udgangen Opsæt X-10 enheder For de op til femten (15) X-10 enheder Kan følgende opsætninger udføres: a. Huskode valg (en kode, i form af et bogstav fra A til P der vil kendetegne den aktuelle installation fra andre i nabolaget). b. Specifik nummerdefinition for hver X-10 enhed (01 15). c. Indlæse 1-vejs X-10 enheder d. Indlæse 2-vejs X-10 enheder (som er i stand til at give status rapportering). Bemærk: Hvis en 2-vejs X-10 enhed er installeret uden at være indlæst i systemet, kan der forekomme forstyrrelser af funktionen for eventuelle 1-vejs X-10 enheder, installeret i samme installation. For hver X-10 enhed kan det vælges om enheden skal have Ingen funktion, eller om den skal Tændes, Slukkes eller Pulses (tændes i en forud fastlagt tidsperiode defineret ved PULSTID), ved følgende betingelser: V/TILKOBLING: Aktiveres Ved Tilkobling og afbrydes ved Frakobling. V/NAT TILKOB.: Aktiveres Ved Nat Tilkobling og afbrydes ved Frakobling. V/FRAKOBLING: Aktiveres ved Frakobling. V/ALARM: Pulsering TIL/FRA under registrering af en alarm i hukommelsen; konstant TIL efter Frakobling og FRA ved sletning af hukommelsesindikationen. V/FORSINK.: aktiveres under indgangs- og udgangsforsinkelser. TIL V/HÅNDSEND: aktiveres ved, at taste funktionsknappen (AUX) på håndsenderen / MCM-140 under forudsætning af, at PGM/X-10 er valgt i lokation 17 i Opsæt Central menuen. V/ZONER: aktiveres ved forstyrrelse i 3 valgfrie zoner, uafhængig af om systemet er til- eller frakoblet. Hvis der vælges Toggle, vil PGM udgangen blive tændt ved en hændelse i disse zoner, og vil blive slukket ved den næste hændelse, skiftevis. DD5467IP 21
34 Første display er KLAR eller IKKE KLAR KLAR 00:00 NORMAL MENU BRUGER MENU INSTALLER MONTØR MENU MODE INDTAST KODE [Montør kode] 1. NY MONTØR KODE 2. INDLÆSNING 3. OPSÆT ZONER 4. OPSÆT CENTRAL 5. OPSÆT KOMM. 6. OPSÆT GSM 7. OPSÆT UDGANGE 8. OPTAG TALE <> FOR AFSLUT OPSÆT PGM OPSÆT INT UDG. OPSÆT X-10 FUNK. OPSÆT X-10 ENHED indv. sirene SÆT HUSKODE strobe lys se X-10 Undermenu (næste side) huskode =A huskode =B HOME <> for indlæs VENT VENLIGST Indlæsningsfejl Indlæsning indlæs FEJLET 2VEJS X10 ENHED 1VEJS X10 ENHED INDLÆSE MENU Sæt X-10 til indlæsning Hvis allerede indlæst PGM (*) <> for test Afslut Indl.Menu Afslut X-10 indlæsning VENT VENLIGST Test fejl Test Dxx: PULSTID pulstid 2s pulstid 30s pulstid 2m pulstid 4m Dxx: LATION (***) pulterkammer bagdør kælder badeværelse <OFF> for slet huskode =P enhed Nr. - - (indtast enhed Nr.) D- -: 1/2VEJS X10 * ** PGM (*) PGM (*) PGM (*) PGM (*) Dxx: V/TILKOBLING Dxx: V/NATTILKOB. Dxx: V/FRAKOBLING Dxx: V/ALARM ingen funktion ingen funktion ingen funktion ingen funktion tænd tænd tænd tænd sluk sluk sluk sluk puls aktiv puls aktiv puls aktiv puls aktiv PGM (*) Dxx: V/FORSINK. ingen funktion tænd sluk puls aktiv bruger zone 5 PGM (*) PGM (*) Dxx: V/HÅNDSENDER Dxx: VZONER PGM V/LINIEFEJL ingen funktion a - zone (**) pgm v/fejl fra tænd c - zone b - zone pgm v/fejl til sluk Vælg med Next ell. Back puls aktiv toggle x - zone Z: Bemærk: PGM VED LINIEFEJL funktionen er kun for PGM ikke Indtast zone numre for X-10. ingen funktion tænd sluk puls aktiv toggle Figur 4.7a Opsæt udgange Hvis PGM er valgt, vil bogstaverne "PGM" vises i displayet i stedet for "Dxx". Ved valget af hver og en af de 3 mulige zoner a, b og c, vælges der et zone nummer og der kan derefter vælges "Ingen funktion", "Tænd", "Sluk", "Puls aktiv" eller "Toggle". 22 DD5467IP
35 *** De valgte muligheder er angivet med en mørk boks i højre side. Hvis en anden værdi ønskes, kan man gense de andre muligheder ved at taste <> eller <BACK> gentagne gange. De muligheder, som ikke aktuelt er valgt har en ledig plads. Vælg den ønskede værdi ved tryk på VIS/ knappen. En liste over zone navne kan ses i afsnit 3 (OPSÆT ZONER). Hver X-10 enhed har et default zone navn: 01- fordør, 02 - garage, 03 - garagedør, 04 - bagdør, 05 børneværelse, 06 kontor, 07 spisestue, 08- spisestue, 09 køkken, 10 stue, 11 stue, 12 soveværelse, 13 soveværelse, 14 gæsteværelse, 15 soveværelse dør. OPSÆT PGM OPSÆT INT UDG. OPSÆT X-10 FUNK. OPSÆT X-10 ENHED BLINK VED ALARM LED V/X10 FEJL FEJL RAPPORT 3FASER & FREKV. SLUK-LYS-TID ingen blink led tændt ingen funktion 3 start - HH:MM A 3 phase 50 Hz alt lys blinker led ikke tændt stop - HH:MM A 3 phase 60 Hz xxxx - 00:00 A Efter valg af Start / Stop, indtastes det ønskede tidspunkt rap. til K.C. 1 ingen funktion v/x10 fejl nej rap. til K.C. 2 ingen funktion v/x10 fejl nej rap. til PAGER ingen funktion v/x10 fejl nej Figur 4.7b X-10 Undermenu rap. til prv.tlf ingen funktion v/x10 fejl nej sendes SMS ingen funktion v/x10 fejl nej 4.8. OPTAGE TALE I denne menu gives der mulighed for at optage korte tale sekvenser til følgende formål: Hus identitet. En meddelelse, der annonceres automatisk ved hver rapportering af hændelser til private telefoner, for identifikation af rapportens oprindelse. 4 bruger navne. Associeres til brugerne 5-8. I tilfælde af hændelser i forbindelse med en af disse brugere, vil brugernavnet blive tilføjet til den meddelelse, der rapporteres via telefonen. (se figur 4.1a) 8. OPTAG TALE HUS IDENTITET - Hold tasten inde INDTAL BESKED (*) (*) TAL NU (f.eks. John s hus ) INDTALING SLUT Slip tasten [2] (**) 5 zone navne. Associeres til specifikke zoner. Disse navne er anvendelige hvis ingen af de allerede eksisterende 26 navne er passende til en given zone (se fig. 3). Optage processen er vist nedenfor. BRUGER NR.5 NAVN BRUGER NR.6 NAVN BRUGER NR.7 NAVN BRUGER NR.8 NAVN Indtal brugernavne 5-8 (f.eks. David, Rose, Mark etc.). Forløbet er identisk med indtaling af HUS IDENTITET. ZONE NAVN #1 ZONE NAVN #2 ZONE NAVN #3 ZONE NAVN #4 ZONE NAVN #5 Indtal bruger zonenavne 1-5 (f.eks. bibliotek, bådehus, etc.), som indtaling af HUS IDENTITET (*) INDTAL BESKED vises straks i displayet. De sorte firkanter forsvinder langsomt en efter en, indtil taletiden er slut. (**) TFor at høre den indtalte besked, tryk og lyt til det afspillede Figur 4.8 Optagelse af tale sekvenser 4.9. TILSTANDSTEST Denne menu giver mulighed for at teste funktionen af alle trådløse detektorer, der anvendes i det beskyttede område, og indsamle informationer om modtagne signalstyrker fra hver detektor, samt at gense de indsamlede oplysninger efter test. Tilstandstesten er udviklet til at klassificere og rapportere 3 signalniveauer, som angivet i følgende tabel: Signal Buzzer reaktion Stærk 2 x succesmelodi ( )( ) God Succesmelodi ( ) Dårlig Fejlmelodi ( ) Forløbet af en Tilstandstest er vist i figur 9. Når du bedes om at udføre en gangtest, gå da rundt i hele det beskyttede område og sørg for, at alle detektorer udløser alarm. Når en detektor giver alarm vil zonenavn, nummer og signalniveau blive angivet som for eksempel, "Badeværelse", "Zone 19 Stærk") og buzzeren vil indikere modtagelsens kvalitet tilsvarende. Vigtigt! Pålidelig signalmodtagelse skal sikres, så ændringer i det sikrede område, der kan forårsage signal dæmpning op til 6 db, ikke vil betyde helt tab af signalmodtagelse. En "Dårlig" signal modtagelse er derfor ikke acceptabel. Hvis der er dårlig modtagelse fra en detektor, skal den eventuelt flyttes og testes igen, indtil modtagelsen som minimum er God, allerbedst Stærk. Dette princip bør følges, såvel under installation som ved efterfølgende system vedligeholdelse. DD5467IP 23
36 TL DETEKT. TEST TILSTANDSTEST (Udfør gangtest) BADEVÆRELSE Z19 STÆRK TILSTANDSTEST Fordør (Skiftevis i 5 sek.) Z1 SVAG STUE Z2 (se figur 4.1a) (Skiftevis i 5 sek.) 9.TILSTANDSTEST Eksempel på test resultat visning (Hver gang tasten trykkes, vises det næste test resultat) Eksempel på test resultat visning Eksempel på test resultat visning TL SIRENE TEST S1 CENTRL VENT VENLIGST... S1 S2 Figur 4.9 Tilstandstest CENTRL=STÆRK CENTRL VENT VENLIGST S2 CENTRL=STÆRK Bemærk STÆRK/GOD/SVAG IKKE (med sirene Nr. S1 eller S2 foran) vises i henhold til signal styrken. S1=sirene 1. S2=sirene 2. CTRL=Alarmcentral = 2 vejs komm BRUGERFUNKTIONER Denne funktion i Montørmenuen, er en genvej til brugerfunktionerne, og den almindelige brugerprogrammeringsmenu. Her kan man: Programmere det 4. (private) telefonnummer Programmere brugerkoder Indlæse håndsendere Vælge talefunktion Sætte automatisk tilkobling fra/til Indtaste tidspunkt for automatisk tilkobling Vælge squawk funktion Indstille Alarmcentralens Ur og tidsformat (24h i DK) Indstille Alarmcentralens dato og datoformat OpsætteTidsskema Der henvises til brugervejledningen for nærmer oplysninger. Bemærk! Hvis en ny brugerkode er identisk med Montørkoden, vil systemet ikke længere give adgang til Montørmenuen med montørkoden. Brugerkoden skal da, via brugermenuen, ændres til en anden kode der ikke er identisk med Montørkoden. Montørkoden vil da igen give adgang til Montørmenuen GENKALD FABRIKSOPSÆTNING PowerMax+ centralen kan resettes således, at de oprindelige fabriksindstillede parametre genkaldes. Fabriksopsætningen genkaldes ved at gå ind i Montør menuens punkt 11 FABRIKSOPSÆTN som vist i illustrationen til højre. Note: For PowerMax+ centraler med 2 Montørkoder, MASTER Kode og MONTØR Kode, er det kun MASTER koden der vil give adgang til at udføre denne reset funktion SERIENUMMER Menupunkt "12. SERIENUMMER" giver mulighed for at aflæse centralens serienummer. (Beregnet for support funktion). Indgang til / afslut fra FABRIKS OPSÆTN. Menu er vist i figur 1.1 Dette er et kort vist display efter hvilket, fabriksopsætning er resat. 11.FABRIKSOPSÆTN <> for genkald INDTAST KODE: [montør kode] VENT VENLIGST RING OP TIL UPLOAD/DOWNLOAD SERVER Denne option tillader montøren at starte et opkald til PowerMax+ konfigurationen til sin database og kan upload/download serveren. serveren uploader downloade forud definerede parametre til PowerMax+. 24 DD5467IP
37 KLAR 00:00 NEXT NORMAL MENU NEXT BRUGER MENU NEXT MONTØR MENU INDTAST KODE: [installer code] 1. NY MONTØR KODE 2. INDLÆSNING 3. OPSÆT ZONER 4. DEFINE PANEL 5.OPSÆT KOMM. 6. OPSÆT GSM 7.OPSÆT UDGANGE 8.OPTAG TALE 9.TILSTANDSTEST 10. BRUGEROPSÆTN. 11. FABRIKSOPSÆTN 12. SERIENUMMER 13. START UL/DL NEXT <> FOR AFSLUT Vises under Opringning Vises under Download Vises i ca. et halvt minut, og Succesmelodien spilles Hvis UL/DL server tif. nr. allerede er defineret (se afsn ) KOMMUNIKERER Opringning DOWNLOADING Download DOWNLOAD Hvis UL/DL server tif. nr. ikke er defineret før (se afsn ) TLFNR. IKKE DEF. Opringning fejlet OPRING FEJLET Download fejlet DOWNLOAD FEJLET Vises i ca. et halvt minut, og fejlsignal melodien spilles Vises i ca. et halvt minut, og fejlsignal melodien spilles Vises i ca. et halvt minut, og fejlsignal melodien spilles Figure 4.13 Start UL/DL 5. TEST PROCEDURER 5.1 Forberedelser Sørg for at alle beskyttede vinduer og døre er låste. Hvis alle zoner er afsikrede (uforstyrrede), vil displayet vise: KLAR HH:MM Hvis systemet ikke er klar (IKKE KLAR), skal du anmode systemet om, at angive årsagen hertil, ved at taste <VIS/> gentagne gange. Årsagen til problemet vil blive vist i displayet og sagt i højttaleren. Foretag de nødvendige skridt for at udbedre problemer, før systemet testes (se afsnit 4.2 nedenfor). 5.2 Tilstandstest For at sikre fuld funktionsdygtighed af detektorer og system, er en tilstandstest nødvendig. For at udføre en sådan test, henvises til fig. 4.9 i Programmeringsvejledningen. 5.3 Håndsender Test Udfør en transmission fra hver af de håndsendere, der anvendes i installationen (i overensstemmelse med listen i afsnit A2, appendiks A). Anvend hver enkelt håndsender til at foretage fuld Tilkobling af alarmcentralen, og foretag straks Frakobling. Ved tryk på håndsenderens Fuld Tilkobling tast, skal alarmcentralens TIL LED-indikator lyse og displayet vise: TILKOBLING FORLAD LALET Og derefter påbegynder udgangsforsinkelsens bip-lyd. Tryk derefter håndsenderens FRAKOBLING ( ) knap. TIL LED-indikatoren skal slukke, annonceringen Frakoblet, klar til Tilkobling" skal høres og displayet vise: KLAR HH:MM Test af EKSTRA knappen () på hver håndsender i overensstemmelse med de oplysninger, som er noteret i tabel A.2, appendiks A. Sørg for at EKSTRA knappen udfører den opgave, som den er programmeret til. Hvis EKSTRA knappen er defineret som STATUS, skal systemets status blive vist i displayet, og annonceres i højttaleren, ved tryk på EKSTRA knappen. Hvis EKSTRA knappen er defineret som STRAKS (INSTANT), tast FULD TILKOBLING (AWAY) knappen og derefter EKSTRA knappen. Skærmen skal herefter vise: STRAKS TILKOBL. (vekslende) FORLAD OMRÅDET Og udgangsforsinkelsens bip-lyd vil begynde. Tryk på FRAKOBLING ( ) knappen straks for at frakoble systemet. Hvis EKSTRA knappen () er programmeret som PGM / X-10 og tilladt at aktivere PGM udgangen, vil tryk på EKSTRA knappen aktivere den enhed, som er tilsluttet PGM udgangen. DD5467IP 25
38 Hvis EKSTRA knappen () er programmeret som PGM / X-10 og tillade at aktivere en eller flere X-10 enheder, vil tryk på EKSTRA knappen aktivere den eller de enheder der er styret af den/de valgte X-10 enheder. 5.4 TIL/FRA Test af enheder De X-10 opsætning oplysninger, som er noteret i Appendiks B til denne manual er meget anvendelige i denne test. Gennemgå tabellen i Appendiks B kolonne for kolonne. Hvis der f.eks. er markeret et X i kolonne TIL tilkobling, som er tilknyttet enhed nr. 1, 5 og 7 tilkobl da systemet og undersøg om de funktioner, der styres af disse enheder rent faktisk også aktiveres under tilkoblingen. Fortsæt på samme måde i de følgende kolonner, således at der etableres den tilstand eller hændelse, som skal aktivere de relevante enheder. Sørg for at alle funktioner aktiveres som programmeret. VIGTIGT! Forinden test af TIMER TIL og ZONER TIL, sørg for at disse former for kontrol er tilladt tast gentagne gange og sørg for at displayet viser: V/TIMER TIL og: V/SENSOR TIL En mørk boks i højre side betyder, at disse funktioner er aktiverede. Den letteste måde, at teste de timede aktiveringer er ved at vælge det 10. punkt i montørmenuen: ( 10. BRUGEROPSÆT. ) og indstille systemets ur til nogle få minutter før det relevante start tidspunkt. Glem ikke at indstille uret til det korrekte tidspunkt efter afslutning af testen. 5.5 Test af nødkaldssendere Klargør de nødkaldssendere, som er tilsluttet en nødkaldszone (i overensstemmelse med listen i tabel A3, appendiks A). F.eks. vil et tryk på nødkaldssender tilsluttet zone 22, vise følgende i displayet: Z22 NØDKALD (vekslende) FORSTYRRET Det anbefales at lade alarmcentralen vise, at denne test gennemføres eller afmontér telefonledningen fra PowerMax under testen for at undgå falske alarmer. 6. VEDLIGEHOLD 6.1 Afmontering af Alarmcentralen A. Frigør PowerMax+ enheden fra beslaget, som vist i figur 3.2, trin 1-5. B. Fjern herefter PowerMax+ enheden fra beslaget. 6.2 Udskiftning af Backup Batteri Udskiftning og første gangs isætning af batteri pakken er næsten identiske operationer (se figur 3.1). Med en ny batteripakke korrekt isat, og låget over batterirummet fastgjort igen, skal PROBLEM indikatoren slukke. Nu vil HUKOMMELSE beskeden blinke i displayet (forårsaget af den sabotage alarm du igangsatte, da du åbnede låget til batterirummet). Slet denne meddelelse ved at Tilkoble alarmen og straks derefter Frakoble den. 6.3 Udskiftning af sikring PowerMax+ har to interne sikringer der har automatisk reset. Derfor er der ikke behov for at udskifte sikringer I enheden. Når en overstrøm situation opstår, vil sikringen afbryde kredsløbet. Når situationen er udbedret og strømmen igen er normal, vil sikringen automatisk resette, og tillade at der igen er forbindelse i kredsløbet. 6.4 Udskiftning/flytning af detektorer Når vedligeholdsarbejdet involverer udskiftning eller flytning af detektorer, er det vigtigt at huske på kravet til en sikkerhedsmargen på 6dB for modtagelse af signalet til PowerMax+. Det er derfor essentielt at der foretages en fuld tilstandstest i henhold til afsnit 9 i Programmerings-vejledningen. Husk! En "Dårlig" signalmodtagelse er ikke acceptabel, som det er anført i slutningen af test proceduren. 7. AFLÆSNING AF HÆNDELSES LOG Alle hændelser bliver gemt i en journal, som indeholder op til 100 hændelser. I log menuen kan man gense de enkelte hændelser én efter en og derefter drage tekniske og funktionelle konklusioner. Hvis loggen er fyldt op (antallet af hændelser overstiger 100) fortsætter PowerMax+ med, at acceptere nye hændelser på bekostning af de gamle hændelser de ældste hændelser slettes, når der registreres nye. Tidspunkt og dato gemmes for hver enkelt hændelse. Når journalen gennemses, vises hændelserne i kronologisk rækkefølge fra de seneste til de ældste. På grund af den begrænsede plads i displayet, beskrives hændelsen først, derefter dato og tidspunkt. De to skærmbilleder vises skiftevis adskillige gange, indtil du taster <> for, at skifte til en ældre hændelse, eller indtil udløbet af en 4 minutters periode ( ikke flere handlinger ), hvorefter systemet vender tilbage til normal funktion. Adgang til journalen gives ved at taste stjernetasten og ikke gennem den almindelige montørmenu. Figur 7 viser forløbet af aflæsning af hændelsesloggen. 26 DD5467IP
39 (*) KODE (Indtast 4-cifret montør kode) (***) HÆNDELSESLOG SLET HÆNDELSER <> FOR AFSLUT Sidste Hændelse. <OFF> FOR SLET (**) (Vend tilbage til normal menu) Ældste Hændelse Figur 7. Læsning / Sletning af hændelses Log * Fra Normal Menu tilstand, tryk på for at gennemse hændelseslog. ** Hændelser vises i 2 dele, for eksempel, "Z13 alarm" og "09/02/99 3:37 P". De to visninger vil blive vist skiftevis indtil der trykkes på igen for at se den næste hændelse. *** Sletning kun mulig hvis Montør kode er indtastet. APPENDIKS A. Placering af detektorer og håndsendere A1. Plan over detektorernes placering Zone Nr (*) 30 (*) Zone Type Detektorens eller senderens placering (i ikke-alarm eller nødkaldszoner) Kime/klokke (Ja / Nej) Kontrollerer PGM (X = ja) Kontrollerer X-10 (X = ja) Zone Types: 1 = Indvendig følge. 2 = Perimeter. 3 = Perimeter følge. 4 = Forsinket 1. 5 = Forsinket 2. 6 = 24timer tavs. 7 = 24timer akustisk. 8 = Brand. 9 = Ikke-alarm. 10 = Nødkald. 11 = Gas. 12 = Vand. 13 = Indvendig. Zone placering: Notér den planlagte placering af de enkelte detektorer. Under programmering kan du vælge en af de 26 mulige zoner (samt 5 særlige zonenavne, som du selv kan tilføje se figur 4.3 i programmeringsvejledningen). * Zonerne 29 & 30 er fast fortrådede zoner. DD5467IP 27
40 A2. Håndsenderliste Håndsender Data Nr. Type Bruger Status eller Straks Tilkobl. 1 Marker den ønskede 2 funktion se afsnit (EKSTRA knappen) i 4 programmeringsvejledningen. 5 EKSTRA knappens funktion UDGANG: PGM UDGANG: X-10 Marker hvilke X-10 enheder der skal aktiveres - se afsnit 7 i programmeringsvejledningen System status Ja Nej Straks Tilkobling A3. Nødkaldssenderliste S. nr. Sender type Tilknyttet zone Navn på indehaver A4. Ikke-alarm sender liste S.nr. Sender type Tilknyttet zone Navn på indehaver Anvisning APPENDIKS B. X-10 enheder og PGM udgangs anvendelse Marker om denne udgang skal aktiveres eller ikke se afsnit 7 i programmeringsvejledningen. Styret TIL TIL TIL TIL TIL TIL Timer TIL Zone nr. TIL TIL Enhed elektrisk Nr. enhed Nat Tilkobl Tilkobl Frakobl Hukommelse Hånd send Forsin kelse Tid TIL Tid FRA a b c liniefejl DD5467IP
41 PGM APPENDIKS C. HÆNDELSESKODER Contact ID Hændelseskoder Code Definition Code Definition 101 Nødkald 351 Fejl på telefonledning 110 Brand Alarm 373 Brand detektor probl. 113 Vand alarm 381 RF overvågn. Probl. 120 Panik Alarm 383 Detektor sabotage 121 Overfald 384 RF-detekt. lavt batteri 122 Tavs Alarm 393 Brand detekt. Rengør 123 Akustisk Alarm 401 Til/Fra af bruger 131 Perimeterzone Alarm 403 Automatisk tilkobling 132 Indvendig zone Alarm 406 Alarm annull. bruger 134 Indgang/Udgang 408 Hurtig tilkobling 137 Sabotage Central 426 Dør åben hændelse 139 Bekræftet Indbrud 441 Nat tilkobling 151 Gas alarm 454 Fail to set event 180 Gas problem 455 Tilkoblingsfejl 301 Strømsvigt 456 Delvis tilkobling 302 Svagt backup batteri 459 Nylig tilkobling hænd. 311 Batteri frakoblet 570 Isolering 313 Montør reset 602 Periodisk testrapport 321 Klokke Gangtest funktion 344 RF-jamming/Støj 641 Aktivitetsopsyn probl. 350 Kommunikationsfejl SIA Hændelseskoder Code Definition Code Definition AR AC Restore GJ Gas trouble restore AT AC Trouble HA Holdup Alarm (duress) BA Burglary Alarm LR Phone Line Restore BB Burglary Bypass LT Phone Line Trouble BC Burglary Cancel OP Opening Report BR Burglary Restore OT Fail to Arm BT Burglary Trouble / PA Panic Alarm Jamming BV Burglary Verified QA Emergency Alarm BZ Missing Supervision RN Engineer Reset CF Forced Closing RP Automatic Test CI Fail to Set RX Manual Test CL Closing Report RY Exit from Manual Test CP Auto Arm TA Tamper Alarm CR Recent Close TR Tamper Restore EA Door Open WA Flood alarm FA Fire Alarm WR Flood alarm restore FT Fire Detector Clean XR Sensor Battery Restore FJ Fire detector trouble XT Sensor Battery Trouble FR Fire Restore YR System Battery Restore GA Gas alarm YT System Battery Trouble / Disconnection GR Gas alarm restore YX Service Required GT Gas trouble 4/2 Hændelseskoder Bemærk: Trådløs sirene rapporterer til Kontrolcentral på zone 31 eller 32. GSM rapporterer til Kontrolcentral på zone 33. Alarmer Zonenr ciffer ciffer A B C D E F A B C D E F Restorals Zonenr ciffer C C C C C C C C C C C C C C C D D D D D D D D D D D D D D D 2. ciffer A B C D E F A B C D E F Overvågningsproblemer Zonenr ciffer ciffer A B C D E F A B C D DD5467IP 29
42 Svagt Batteri Zonenr ciffer ciffer A B C D E F A B C D Tvungen tilkobling 8 brugere Bruger nr ciffer A A A A A A A A 2. ciffer Zone Isolering Zone # st digit A A A A A A A A A A A A A A A B B B B B B B B B B B B B B B 2 nd digit A B C D E F A B C D E F Panik / 24 Timer - 8 brugere Brugernr Panik CP Overfald 1. ciffer ciffer A Nattilkobling (HOME) og Fuld tilkobling (AWAY) Brugernr Alarm Annull Nylig tilkobl. 1. ciffer E E E E E E E E E E 2. ciffer C Frakobling Brugernr ciffer F F F F F F F F 2. ciffer Problem Hændelse Sikr. Fejl Sikr. Reset Jamming Jamming Reset Strøm Fejl Strøm Reset Central svagt Batteri Central svagt batteri Reset Central sabotag. 1. ciffer ciffer C D E F Hændelse Centr. Sabot. reset Ikke aktiv KOMM. & LINIE Reset Indgangs Test Udgangs Test Auto Test 1. ciffer ciffer 7 8 A D E F Forklaring til Scancom Rapport Protokol Data Format SCANCOM data formatet består af 13 decimal cifre opdelt i 4 grupper, fra venstre mod højre, som vist i højre side. Hver kanal er associeret med en bestemt hændelse som følger: 1. "C" : Brand 5. "C": Alarm annullering 2. "C" : Person angreb 6. "C": Nødkald 3. "C" : Indbrud 7. "C": 2. alarm 4. "C" : Til/Fra 8. "C": Fejl meddelelser Konto Kode Kanaler 1-4 aaaa cccc cccc s Cifret i denne position angiver status for kanal 1 Kanaler 5-8 Cifret i denne position angiver status for kanal 8 Scancom Data Format System status: Ingen prbl., test, svagt batteri 30 DD5467IP
43 APPENDIKS D. PROGRAMMERBARE ZONE TYPER D1. Perimeter Zoner Perimeter zoner er de zoner der danner den ydre ramme om det beskyttede område. De er afhængige af detektorer som beskytter døre, vinduer og vægge. Når zonen bliver forstyrret ved at åbne døren/vinduet eller gennembryde muren, vil alarmen straks blive aktiveret D2. Indvendige Følge Zoner En ikke-indgangs/udgangs zone. Typisk en Indvendig zone der ligger på indgangs/udgangs-vejen og som håndteres som en indgangs/udgangszone under indgangs/udgangs tiden. D3. Perimeter Følge Zoner En ikke-indgangs/udgangs zone. Typisk en Perimeter zone der ligger på indgangs/udgangs-vejen og som håndteres som en indgangs/udgangszone under indgangs/udgangs tiden. D4. Forsinkede zoner En forsinket zone har en udgangs- og indgangsforsinkelse afhængig af systemets programmering. Advarselsbip vil lyde under disse forsinkelser medmindre du vælger at gøre dem tavse. Udgangsforsinkelse: Udgangsforsinkelsen påbegyndes så snart systemet tilkobles. Forsinkelsen vil give brugeren mulighed for at forlade det sikrede område via indvendige zoner eller adgangsvej inden den egentlige tilkobling effektueres. Når udgangsforsinkelsen starter vil buzzeren bippe langsomt, når der er 10 sekunder tilbage af udgangsforsinkelsen vil bippene blive hurtigere. PowerMax har to typer af forsinkelseszoner, for hvilke forskellige forsinkelses tider kan defineres. Indgangsforsinkelse: Indgangsforsinkelsen påbegyndes, så snart brugeren går ind i det beskyttede område via en specifik adgangsvej (indgangen detekteres af en detektor i en forsinket zone). For at undgå en alarm, skal brugeren nå frem til tastaturet via indvendige zoner (som bliver til følgezoner under indgangsforsinkelsen) og frakoble systemet inden udløbet af forsinkelsen. Når indgangs-forsinkelsen starter vil buzzeren bippe langsomt, når der er 10 sekunder tilbage af forsinkelsen vil bippene blive hurtigere. D5. 24-Timers Zoner 24-timers zoner anvendes til PANIK alarm, perimeter detektorer og sabotagealarmer. De aktiverer alarmen uanset om systemet er til- eller frakoblet. 24-Timers zone Tavs. Ved detektering, vil denne zone aktivere en tavs alarm, hvilket vil sige, at sirenen ikke lyder, men PowerMax+ foretager opkald til telefonnumre og rapporterer hændelsen til kontrolcentralen og/eller private telefoner, afhængig af programmeringen. 24-Timers zone akustisk. Ved alarm, aktiveres en sirene, men PowerMax+ foretager også opkald til telefonnumre og rapporterer hændelsen til kontrolcentralen og/eller private telefoner, afhængig af programmeringen. D6. Brand Zoner En brandzone anvendes til røgdetektorer og er konstant aktiv (brandalarmen aktiveres uanset om systemet er tileller frakoblet). Ved detektering af røg. Vil en pulserende sirene straks lyde og hændelsen vil blive rapporteret via telefonlinien. D7. Ikke-Alarm Zoner En ikke-alarm zone tager ikke direkte del i alarmsystemet. Zonernes hovedfunktion er at udføre fjernbetjeningsopgaver, så som at åbne/lukke en port, aktivere/afbryde lys og lignende opgaver. Der aktiveres således ikke nogen alarm i tilknytning til ikke-alarm zoner. Ved fjernbetjening af elektriske enheder, kan du definere det ønskede ikke-alarm zone nummer og indlæse en håndsender eller anden trådløs enhed (detektor) til hver af disse zoner. Herefter skal du sikre dig, at disse zoner har tilladelse til at kontrollere PGM udgang, X-10 enheder eller begge enheder (se afsnit 6). Du kan nu vælge zonerne (højst 3), som skal kontrollere hver udgang. Udgangen kan kontrollere den eksterne elektriske enhed. Bemærk: Enhedskontrol kan også udføres ved at alle indehavere af håndsendere trykker på AUX [] knappen. Denne metode kan anvendes under forudsætning af at du har programmeret AUX [] tasten til PGM/X-10 kontrol (se afsnit 4.17) og at PGM udgangen og X-10 enhederne er programmeret til at blive kontrolleret af håndsendere (se afsnit 7). D8. Nødkald Zoner Du kan udstyre handicappede, syge eller ældre mennesker med en armbåndssender/smykkesender. I nødstilfælde kan de trykke på senderen og dermed få PowerMax+ til at aktivere et Nødkald til kontrolcentralen eller private telefoner, afhængig af programmeringen. For at anvende denne funktion skal du blot definere de ønskede antal zoner som nødkaldszoner og indlæse håndsenderen til de respektive zoner. Når dette er gjort skal superbrugeren uddele håndsenderne til de potentielle brugere. D9. Gas Zone En Gas zone er permanent aktiv (en gas alarm udløses uanset om systemet er tilkoblet eller frakoblet). Ved detektering af gas i rummet hvor detektoren er placeret, vil centralen rapportere hændelsen via telefonen til kontrolcentralen. D10. Vand Zone En Vand zone er permanent aktiv (en vand alarm udløses uanset om systemet er tilkoblet eller frakoblet). Ved detektering af vand på gulvet i rummet hvor detektoren er placeret, vil centralen rapportere hændelsen via telefonen til kontrolcentralen. DD5467IP 31
44 APPENDIKS E. POWERMAX+ KOMPATIBLE ENHEDER E1 PowerMax+ kompatible detektorer De enheder og detektorer, som er kompatible med PowerMax+ alarmcentralen, er pakket med deres egen monteringsvejledning. Læs den omhyggelig og foretag derefter montering som beskrevet. A. PIR detektorer De trådløse infrarøde (PIR) detektorer, der anvendes i systemet er PowerCode detektorer, som anvender en unik 24-bit identifikationskode. PowerMax er i stand til at lære hver enkelt detektors identifikationskode og koble den til en specifik zone (se afsnit 4.3 i programmeringsvejledning). Nogle enheder er vist i figur 4,5 og 6: Figur 4 NEXT Figur 5 Figur 6 K9- MCPIR-3000 DISCOVERY 85 MCW or K-940 MCW K9-80/MCW Bemærk: K-940 MCW, Discovery K9-80/MCW og NEXT K9-85 MCW er husdyr immune detektorer. I tilknytning til den unikke identifikationskode sender hver detektor en rapport, som indeholder statusinformationer: Detektoren er i alarm (eller ikke). Detektoren er udsat for sabotage (eller ikke). Batteriet er svagt (eller normalt). Dette er en overvågningsrapport. Hvis nogle af detektorerne detekterer en bevægelse, vil den afgive en alarmrapport til alarmcentralen. Hvis alarmcentralen er tilkoblet, vil alarmen blive udløst. B. Magnetkontakt MCT-302 (se figur 7) er en PowerCode magnetkontakt, som anvendes til at detektere åbning af døre og vinduer. Alarmkontakten er lukket, så længe døren eller vinduet er lukket. Figur 7 MCT-302 Herudover har enheden en ekstra alarmindgang, der fungerer som en separat trådløs sender. Denne type detektor sender (eller sender ikke) en rapport om tilbage til normal til alarmcentralen, afhængig af indstillingen af en intern DIP-switch. Rapporten fortæller dig, gennem alarmcentralens indikatorer, om døren eller vinduet er åben eller lukket. C. Trådløs sendermodul til trådførte detektorer MCT-100 (se fig. 8) er en PowerCode sender, der hovedsagelig anvendes som sendermodul for 2 almindelige magnetkontakter monteret i 2 vinduer i samme lokale. MCT-100 har to indgange, som hver især fungerer som uafhængige sendere og sender forskellige PowerCode ID er. Hver indgang sender (eller sender ikke) en rapport om tilbage til normal, afhængig af indstillingen af intern DIP switch. D. Trådløs røgdetektor. MCT-425 er en fotoelektrisk røgdetektor udstyret med PowerCode sender. Når den er tilsluttet en brandzone, vil den aktivere en brandalarm ved detektering af røg. Figur 8 MCT-100 Figur 9. MCT-425 E. Trådløs glasbruds detektor MCT En akustisk detektor udstyret med en PowerCode sender. MCT 501 foretager automatisk en restore efter hver detektering og sender derfor ikke rapport herom til alarmcentralen. Figur 10 MCT-501 E2 PowerMax+ kompatible håndsendere Bemærk: Hver håndsender er pakket med sin egen brugervejledning, som skal anvendes ved opsætning af alarmcentralen. Overdrag denne dokumentation til Master Brugeren af alarmsystemet. PowerMax+ er kompatibel med håndsendere, som anvender PowerCode og CodeSecure afkodning. PowerCode håndsendere, med flere knapper (kanaler), sender samme kode hver gang, der trykkes på samme knap. De kan bl.a. anvendes til nød signalering. De kan ikke anvendes til at Til og Frakoble alarmcentralen. CodeSecure håndsendere med skiftende kode disse sender en ny kode hver gang, der trykkes på samme knap. Dette giver et væsentlig højere sikkerhedsniveau, især ved Til og Frakobling, idet koden ikke kan kopieres (opsnappes) af uautoriserede personer. I det følgende gennemgås basisfunktionerne på nogle af de kompatible håndsendere. De mulige egenskaber for hver knap er indikeret på hver tegning. A. MCT-234 (Fig. 11): Håndsender, som leveres sammen med PowerMax. Du kan programmere EKSTRAknappen til at udføre en række forskellige opgaver, afhængig af brugerens behov. B. MCT-231 / 201 (Fig. 12): Enkelt-knap smykke-sender. MCT-231 (CodeSecure) og MCT-201 (PowerCode) kan udføre de angivne funktioner. Begge smykkesendere ser ens ud. C. MCT-134 / 104 (Fig. 13): 4- knaps håndsender. MCT- 134 (CodeSecure) kan erstatte MCT-234 håndsenderen. MCT-104 (Power- Code) kan udføre nødkald og ikke-alarm funktioner. Begge håndsendere er ens. D. MCT-132 / 102 (Fig. 14): 2-knaps håndsender. MCT- 132 (CodeSecure) kan udføre de viste funktioner MCT-102 (PowerCode) kan udføre nødkald og ikkealarm funktioner. Begge håndsendere ser ens ud. E. MCT-131 / 101 (Fig. 15): Enkelt-knap håndsender. MCT-131 (CodeSecure) og MCT-101 (PowerCode) kan udføre de angivne funktioner. Begge håndsendere ser ens ud. Fuld Tilkobling Nat- Tilkobling 32 DD5467IP Frakobling Ekstra Figur 11. MCT-234 MCT-201: Nødkald eller ikkealarm MCT-231: Kun frakobling Figur 12. MCT-231 / 201 Fuld Tilkobling Frakobling Ekstra PANIK Nattilkobling Bemærk: De angivne funktioner er de samme som for MCT-134 Figur 13. MCT-134 / 104 Frakobling Fuld Tilkobling Figur 14. MCT-132 / 102 MCT-101: Nødkald eller ikke-alarm funktion MCT-131: Kun frakobling Figur 15. MCT-131 / 101
45 F. MCT-211 (Fig. 16) Dette er en vandtæt armbåndssender (PowerCode) som kan udføre nødkald og ikkealarm funktioner. Nødkald eller ikke-alarm funktion Figur 16. MCT-211 E3 PowerMax+ kompatibel Trådløs Sirene MCS-700 trådløs sirene (fig. 17) kan integreres med PowerMax+ i situationer hvor kabelføring er besværlig eller umulig. MCS- 700 er en fuldt overvåget, 2-vejs kommunikations enhed (den inkluderer en modtager, for modtagelse af aktiverings kommandoer fra alarmcentralen, samt en sender der periodisk sender status meddelelser til alarmcentralen). Figur 17 Trådløs Sirene Når en aktiverings kommando modtages fra PowerMax+, vil sirenen aktivere sin lydgiver, og starte sit stroboskop lys (strobe lys hvert 1,5 sekund). E4. PowerMax+ kompatibelt GSM modem GSM modemet giver PowerMax+ systemet mulighed for at kommunikere via et GSM netværk. Nærmere detaljer om GSM modemets funktioner og dets forbindelse kan ses i GSM Modem installationsvejledning. GSM Modem DD5467IP 33
46 Federal Communications Commission (FCC) Statements FCC PART 15 STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The digital circuits of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: Re-orient or re-locate the receiving antenna. Increase the distance between the device and the receiver. Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. Consult the dealer or an experienced radio/tv technician. FCC PART 68 STATEMENT This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. This equipment uses the following jacks: An RJ31X is used to connect this equipment to the telephone network. The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice that will enable you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved. There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product. This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs. When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early morning or late evening. Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dialing equipment must be connected to a properly installed RJ31X jack that is electrically in series with and ahead of all other equipment attached to the same telephone line. If you have any questions concerning these instructions, you should consult your telephone company or a qualified installer about installing the RJ31X jack and alarm dialing equipment for you. Supplier Declaration of Conformity (SdoC) Visonic, located at 30, 24 Habarzel street, Tel Aviv 69710, Israel, hereby certifies that the Wireless Alarm Control Panel model PowerMax+, bearing the labeling identification number US:VSOAL03BPOWERMAX+ complies with the Federal Communication Commission s ( FCC ) Rules and Regulations 47 CFR Part 68, and the Administrative Council on Terminal Attachments ( ACTA ) adopted technical criteria: TIA/EIA/IS-968, Telecommunications - Telephone Terminal Equipment - Technical Requirements for Connection of Terminal Equipment to the Telephone Network, July /10/2002 Yaacov Kotlicki Chairman 34 DD5467IP
47 DD5467IP 35
48 WARRANTY Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its products hereinafter referred to as "the Product" or "Products" to be in conformance with its own plans and specifications and to be free of defects in materials and workmanship under normal use and service for a period of twelve months from the date of shipment by the Manufacturer. The Manufacturer's obligations shall be limited within the warranty period, at its option, to repair or replace the product or any part thereof. The Manufacturer shall not be responsible for dismantling and/or reinstallation charges. To exercise the warranty the product must be returned to the Manufacturer freight prepaid and insured. This warranty does not apply in the following cases: improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other than the Manufacturer. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express or implied, including any warranty of merchantability or fitness for a particular purpose, or otherwise. In no case shall the Manufacturer be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties whatsoever, as aforesaid. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products. The Manufacturer does not represent that its Product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. User understands that a properly installed and maintained alarm may only reduce the risk of events such as burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such will not occur or that there will be no death, personal damage and/or damage to property as a result. The Manufacturer shall have no liability for any death, personal and/or bodily injury and/or damage to property or other loss whether direct, indirect, incidental, consequential or otherwise, based on a claim that the Product failed to function. However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, the Manufacturer's maximum liability shall not in any case exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. Warning: The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week. For various reasons, including, but not limited to, changes in environmental conditions, electric or electronic disruptions and tampering, the Product may not perform as expected. The user is advised to take all necessary precautions for his /her safety and the protection of his/her property. 6/91 VISONIC LTD. (ISRAEL): P.O.B TEL-AVIV ISRAEL. PHONE: (972-3) , FAX: (972-3) VISONIC INC. (U.S.A.): 65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT PHONE: (860) , (800) FAX: (860) VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) FAX: (0870) INTERNET: VISONIC LTD POWERMAX+ Installer Guide DD5467IP (REV. 0, 5/04) R 36 DD5467IP
49 POWERMAX+ Fuldt overvåget trådløs alarmcentral INDHOLD 1. INTRODUKTION Oversigt Systemets Faciliteter Fagudtryk Symboler anvendt I vejledningen Taster på Alarmcentralen Multifunktionshåndsender Tale meddelelser Screen Saver funktion SIKRING AF DET BESKYTTEDE OMRÅDE Sikkerhedsrelaterede taster Forberedelse af Tilkobling Fuld Tilkobling AWAY Nat Tilkobling HOME Skift fra Nat Tilkobling til Fuld Tilkobling Skift fra Fuld Tilkobling til Nat Tilkobling Straks Tilkobling Tvungen Tilkobling Tilkobling med Frakoblingsrapport Udløse en Panik Alarm Frakoble og afbryde Alarm Sirene virkemåde TALE OG LYDBETJENING Taster til betjening af tale og lyd Justering af lydstyrken Tale TIL/FRA Indtal en besked Afspil besked Dørklokke TIL/FRA STYRING AF ELEKTRISKE ENHEDER Styringsmuligheder og taster Manuel Tænd af enheder Manuel Sluk af enheder Lys Dæmp/Forøg Automatisk Tænd/Sluk styring AFLÆS ALARMHUKOMM. OG PROBLEMOPLYSN Genkald indhold af alarm- og sabotagehukomm Genkald problemoplysninger...12 Brugervejledning 5.3 Visning af Hukomm. Og Problemoplysn. samtidigt Udbedring af problemer SPECIELLE FUNKTIONER Holde opsyn med personer I hjemmet Nødkald efter hjælp Fjernbetjening via telefon Modtage meddelelse via telefon Fjernkontrol med SMS Rapportering med SMS Rapportering til en Pager Udføre Gangtest BRUGEROPSÆTNING Hvilke opsætninger har du behov for? Brugeropsætningsmenu Isolering af Zoner Se listen over isolerede zoner Genkald den sidste isoleringsliste Programmering af 4 telefonnumre Programmering af brugerkoder Indlæsning af håndsendere og trådløse tastaturer Sletning af håndsendere og trådløse tastaturer Indstilling af talemuligheder Automatisk Tilkobling Sæt automatisk tilkoblings tidspunkt Squawk menu Indstilling af Tid og Format Indstilling af Dato og Format Tidsskema Funktion AFLÆS HÆNDELSESLOG Beskrivelse Af hændelseslog Aflæsningsprocedure VEDLIGEHOLD Udskiftning af Backup Batteri Udskiftning af batterier i trådløse enheder Periodisk Test Rengøring af Alarmcentralen SYSTEMBEGRÆNSNINGER APPENDIKS A. ORDBOG Oversigt over vigtigste alarmcentral brugerfunktioner Fuld tilkobling (AWAY)... + [kode]* Straks fuld tilkobling (AWAY-INSTANT)... + [kode]* + Nat tilkobling (HOME)... + [kode]* Straks nat tilkobling (HOME-INSTANT)... + [kode]* + Bekræftet tilkobling (AWAY-LATCHKEY... + [kode]* + Tvungen fuld tilkobling (AWAY) (system ikke klar)... + [kode]* + (for at gøre buzzer tavs) Tvungen nat tilkobling (HOME) (system ikke klar)... + [kode]* + (for at gøre buzzer tavs) Frakobling og afbryde alarm... + [kode] * Superbrugerkoden er fra fabrikken sat til Koden er ikke nødvendig, hvis montøren har tilladt hurtig tilkobling. DD5467U 1
50 Kære kunde, Tak fordi du valgte PowerMax en meget avanceret trådløs alarmcentral produceret af Visonic Ltd. Noter venligst følgende oplysninger om montøren i tilfælde af at du får behov for assistance: Firmanavn: Telefonnr.: Kontaktperson: Sørg ligeledes for at have navn og telefonnummer på den kontrolcentral, som alarmcentralen rapporterer til. Hvis der rettes henvendelse til kontrolcentralen, skal kontonummer oplyses for at identificere din alarmcentral. Disse oplysninger kan fås hos montøren og bør noteres nedenfor. Navn på kontrolcentral: Telefonnr.: Kontonr.: Hvis systemet er opsat til at kontakte private telefonnumre noter da de 3 telefonnumre, som montøren har programmeret systemet til at rapportere til, samt følg-mig nummeret: Telefon nr. 1: Telefon nr. 2: Telefon nr. 3: Telefon nr. 4: OVERSIGT OVER AKUSTISKE SIGNALER Lydsignal Sekvens Betydning (-) Kun en gang Du har foretaget et tastetryk på tastaturet (- -) Kun en gang Systemet vender automatisk tilbage til forrige punkt (- - -) En gang pr. minut Der er netop konstateret et problem (- - - ) Kun en gang Kommando/funktion er blevet gennemført ( ) Kun en gang Forkert kommando forkert kode handlingen bliver ikke gennemført Langsom bip i starten ( ) hurtigere bip i de sidste 10 sekunder ( ). Kun en gang, under en tidsforsinkelse fastsat af montøren. ( ) Kontinuerlig tone under tilkobling (vedvarer indtil de sidste 10 sekunder af udgangsforsinkelsen er gået) Advarsel om udgangsforsinkelse ved tilkobling af systemet samt indgangsforsinkelse via en forsinket zone. Tvungen tilkobling gennemføres mens systemet ikke er klar (IKKE KLAR). Tonen afbrydes ved at trykke på tilkoblingsknappen endnu engang. (ding-dong) Kun en gang Der er detekteret en forstyrrelse i en dørklokkezone (mens systemet er frakoblet). L.E.D. Opførsel Betydning TIL PROBLEM KLKE POWER Lyser konstant Blinker Slukket Lyser konstant Slukket Lyser konstant Slukket Lyser konstant Slukket L.E.D. INDIKATORSIGNALER Systemet er fuldt tilkoblet (AWAY) Systemet er nat tilkoblet (HOME) Systemet er i øjeblikket frakoblet Der er konstateret problemer Ingen problemer alt fungerer korrekt. Dørklokkefunktionen er aktiv Dørklokken lyder, hvis en dørklokke-zone forstyrres. Dørklokkefunktionen er ikke aktiv Dørklokken lyder ikke, selvom en dørklokkezone forstyrres. Strømforsyningen til alarmcentralen sker via ledningsnettet. Strømforsyningen til alarmcentralen sker via backupbatteriet. 2 DD5467U
51 SIRENE SIGNALER Alarm type Grafisk præsentation af signalet Beskrivelse af signalet Indbrud / 24 timer/ panik Kontinuerlig aktiv Brand... AKTIV - AKTIV - AKTIV - pause - AKTIV - AKTIV - AKTIV - pause... Test (både ekstern og intern sirene) AKTIV i 2 sekunder (en gang) NYTTIGE TIPS TIL POWERMAX+ BRUGERE Afbryde alarmen: Når alarmen lyder tryk på FRAKOBLING ( ) på håndsenderen eller tryk på tastaturet og indtast adgangskoden (fabriksindstillingen er 1111). Stop problem bip: Når der opstår et problem i systemet, vil PROBLEM indikatoren på frontpanelet lyse, og buzzeren vil afgive en sekvens af 3 bip, en gang i minuttet. Hvis du ikke ønsker at udbedre problemet straks, og bippene er generende, tast FRAKOBLING ( ) på håndsenderen, eller tryk på tastaturet og indtast adgangskoden (fabriksindstillingen er 1111). Dette vil gøre buzzeren tavs i 4 timer, hvorefter bippene vil blive genoptaget. Buzzeren vil dog under alle omstændigheder være tavs i nattetimerne. Perimeter og indvendige zoner contra 24-timers zoner: De fleste detektorer er tilknyttet en perimeter eller indvendig zone. Disse zoner udløser kun en alarm hvis systemet er tilkoblet. De øvrige detektorer er tilsluttet en 24- timers zone som udløser en alarm, uanset om systemet er tilkoblet eller frakoblet. Tilkobling mens perimeterzonerne ikke er sikret (dør og/eller vinduer er åbne): Displayet vil vise IKKE KLAR hvis beskyttede døre eller vinduer er åbne. Du kan finde ud af, hvilke zoner, der ikke er klar (IKKE KLAR) ved at trykke på <VIS/> knappen. Du kan løse problemet ved at lukke døre/vinduer. Hvis du vælger ikke at gøre det, check da om montøren har givet tilladelse til at foretage automatisk isolering af zoner, som ikke sikres ved ophør af udgangsforsinkelsen (hvis dette er tilladt, vil en stemmebesked meddele, at en tvungen tilkobling foretages). Isolerede zoner vil da ikke være aktive og dermed heller ikke yde beskyttelse under tilkoblingsperioden. Hvis du ønsker at isolere zonen, og montøren har tilladt automatisk isolering, kan du blot lade vinduet eller døren forblive åben og foretage tilkobling af systemet (en stemmebesked vil meddele, at en tvungen tilkobling foretages). Opnå adgang til 24-timers zoner: Hvis du ønsker adgang til en detektor, defineret som en 24 timers zone, uden at aktivere alarmen, gøres dette som følger: Tast <> -displayet viser: NORMAL. Tast <> igen displayet viser: BRUGER INDSTILLING. Tast <VIS/> - displayet viser: INDTAST KODE. Indtast den 4-cifrede <brugerkode> - buzzeren afgiver succes tone (- - - ). Du har nu adgang til 24-timers detektoren i 4 minutter. Når de 4 minutter er gået, vil systemet automatisk vende tilbage til normal. Slet fejlalarmer: Under alarm vil den indbyggede sirene først blive aktiveret i en begrænset periode (indstillet af montøren). Herefter vil den eksterne sirene lyde og sende en alarmrapport til kontrolcentralen. Hvis alarmen fejlagtigt aktiveres, kan du blot frakoble systemet før den eksterne sirene aktiveres alarmen vil således ikke blive rapporteret til kontrolcentralen. Hvis alarmen fejlagtigt aktiveres og den eksterne sirene allerede er aktiveret, kan du stadig frakoble systemet inden for en tidsfrist, indstillet af montøren (valgfrit fra 1 til 15 minutter). Hvis du når at frakoble systemet i tide, vil alarmcentralen automatisk afgive en ANNULLER ALARM rapport til kontrolcentralen. Du når ikke ud, inden udgangsforsinkelsen udløber: Hvis du forlader det sikrede område efter udgangsforsinkelsen er udløbet (bippene stopper), vil systemet opføre sig, som om du lige er trådt ind. Nedtælling af Indgangsforsinkelsen starter, og bippene for indgangsforsinkelse lyder. For at undgå alarm skal du frakoble systemet, før forsinkelsen udløber. Indbrud, mens du var ude: Hvis du hører alarmsirenen, når du igen skal til at gå ind i lokalet, og lyset er tændt selv om det skulle være slukket, er der måske en indbrudstyv, eller også er der opstået en anden begivenhed, som har aktiveret alarmen. Forsøg ikke at konfrontere tyven bliv udenfor og tilkald politiet. DD5467U 3
52 1. INTRODUKTION 1.1 Oversigt PowerMax+ er en trådløs alarmcentral, som yder beskyttelse mod indbrud, brand og sabotage. Herudover kan den anvendes til at overvåge aktivitet i huset f.eks. børn, svagelige og ældre personer. Statusinformationer præsenteres såvel akustisk som visuelt på displayet, og i de fleste tilfælde fortæller en stemme, hvad du skal foretage dig. PowerMax+ styres via et kontrolpanel (figur 1), som er udviklet til at indsamle oplysninger fra forskellige detektorer, strategisk placeret i det sikrede område (figur 2). Når systemet er frakoblet forsyner PowerMax+ dig med visuelle og akustiske statusinformationer og aktiverer alarmen, hvis der detekteres røg, eller hvis en 24-timers zone forstyrres (en zone, som er aktiv 24 timer i døgnet). Når systemet er tilkoblet, vil PowerMax+ aktivere alarmen, hvis en af de aktive zoner forstyrres. Du skal anvende en 4-cifret superbrugerkode for at få fuld adgang til systemet. Med denne kan du autorisere yderligere 7 personer til systemet ved at tildele dem deres egen sikkerhedskode. Desuden kan du tilkoble 8 multifunktions håndsendere, som giver adgang til de vigtigste brugerfunktioner, uden du skal bruge alarmcentralens tastatur. Systemet kan identificere en bred vifte af hændelser alarmer, forsøg på sabotage af detektorer samt adskillige problemtyper. Hændelserne bliver automatisk rapporteret via telefonnettet til kontrolcentralen (digitalt), eller til private telefoner (klar tale). Den person, som modtager en sådan rapport forudsættes at undersøge hændelsen og reagere herpå. INDBYGGET SIRENE LED INDIKATORER MIKROFON HØJTTALER DISPLAY BETJENINGS- TASTER Figur 1. Alarmcentral med dækslerne lukket TASTATUR DÆKSEL (LUKKET) VIGTIGT! Alt hvad du behøver at vide for at sikre et område er beskrevet i afsnit 2 i denne vejledning. Hvis du ikke er bekendt med de brugte udtryk, henvises der til ordbogen i Appendiks A bagest i vejledningen. 15 ELEKTRISKE ENHEDER (STYRET VIA DEN EKSISTERENDE ELEKTRISKE INSTALLATION I HUSET) TIL/FRA PÅ BAGGRUND AF FORSKELLIGE BETINGELSER, PROGRAMMERET AF MONTØREN. Gardiner Køle/Varme enhed Radio TV GSM ENHED TLF. NØDKALDS- SENDER MAGNETKONTAKT (DETEKTOR TIL DØR OG VINDUE) UNIVERSAL SENDER X-10 #1 X-10 #2 X-10 #3 X-10 #4 X-10 #5 X-10 #6 X-10 #15 EKSISTERENDE ELEKTRISKE INSTALLATION LAL COMPUTER (OPTION) POWERLINE INTERFACE MODUL EKSTERN SIRENE PERSONSØGER FIRMAETS COMPUTERS GSM TELEFON- CENTRAL KONTROL- CENTRAL PERSONSØGER TRÅDLØSE DETEKTORER (OP TIL 28 ENHEDER) INSTALLEREDE I DET BESKYTTEDE OMRÅDE RØG DETEKTOR BEVÆGELSES DETEKTOR TLF. LINE INDBYGGET SIRENE TELEUDBYDER 4 PRIVATE TELEFONER VAND DETEKTOR KONTROL AF ENHEDER I OVERENSSTEMMELSE MED MONTØRENS PROGRAMMERING GAS DETEKTOR KONTROLCENTRAL TRÅDFAST MAGNET- KONTAKT BRUGER TRÅDLØST TASTATUR MULIGHED FOR AT TILKNYTTE OP TIL 8 HÅNDSENDERE TIL SYSTEMET Figur 2. Typisk System Opsætning 4 DD5467U
53 1.2 Systemets faciliteter PowerMax+ har en række unikke funktioner: Flere tilkoblingsmetoder: fuld tilkobling (AWAY), nat tilkobling (HOME), straks fuld tilkobling (AWAY- INSTANT), straks nat tilkobling (HOME-INSTANT) og tilkobling m/frakoblingsrapport. LCD display: Status informationer vises i displayet i klar tekst. Ur: Den aktuelle tid vises i højre side af displayet. Flere rapporteringsmuligheder: Begivenheder rapporteres automatisk, afhængig af dit ønske, til kontrol- central, private telefoner eller personsøger. Selektiv rapportering: Montøren kan definere til hvem eller hvor, en given begivenhed skal rapporteres. Frakoblingsrapport: Hvis systemet tilkobles med ønske om frakoblingsrapport, afgiver systemet automatisk en rapport ved frakobling af brugerne 5-8. Meddelelser og instruktioner udtales: Forud indtalte statusrelaterede meddelelser bliver talt via den indbyggede højttaler (hvis stemmefunktionen er aktiv se afsnit 7.10). Udveksle meddelelser: Før du forlader lokaliteterne, kan du indtale en kort besked til de øvrige brugere, som ankommer senere. Ved ankomst kan du lytte til indtalte beskeder indtalt af andre brugere til dig. Tastatur og trådløs kontrol: Der kan opnås fuld kontrol over systemet via tastaturet eller udføre de vigtigste brugerfunktioner via håndsenderen. Adgang/betjening via telefon: Du kan få adgang til PowerMax+ via telefonen og derved til- og frakoble systemet, samt modtage statusinformationer fra systemet. Numeriske taster fungerer som funktionstaster: Når alarmcentralen er frakoblet, anvendes de numeriske taster til at udføre forskellige funktioner. Et lille ikon (tegning/billede) på hver tast hjælper dig med at huske tastens funktion. Styring af elektriske enheder: Lys, varmeovne, kaffemaskine etc. kan styres med PowerMax+ via såkaldte X-10 moduler, der købes som ekstraudstyr. Enhederne styres af PowerMax+, direkte via husets elinstallation uden brug for yderligere netværk. PGM fjernbetjening: Garageport, energi-lamper og andre enheder kan tændes/åbnes og slukkes/lukkes via den specielle PGM udgang (programmerbar). Montøren kan definere udgangens funktion i overensstemmelse med dine ønsker. Indhente oplysninger: Du kan indhente statusinformationer, probleminformationer og gennemse alarmhændelser gemt i hukommelsen i displayet eller som klar tale. Opsyn med ældre, psykisk handicappede og svagelige personer: Systemet kan programmeres til at vise/angive aktivitet i et sikret område og udsende alarm, hvis en person under opsyn forbliver samme sted i for lang tid. Nødkald: Minisendere kan uddeles til forskellige personer og anvendes til at afgive nødkald efter hjælp. Frakobling under trussel: Hvis en bruger trues til at frakoble systemet, kan han bruge en speciel kode der frakobler systemet som normalt, men som samtidig sender en lydløs alarm til kontrolcentralen (se 2.13F). Systemovervågning: Alle trådløse detektorer i det sikrede område, sender periodiske overvågningsrapporter. Hvis en sådan meddelelse ikke modtages, vil PowerMax+ afgive problemrapport om INAKTIV DETEKTOR. Montøren kan frakoble funktionen, hvis dette ønskes. Batteriovervågning: Du behøver ikke at bekymre dig om svage batterier. PowerMax giver rapport om SVAGT BATTERI i displayet, når batteriet i en af de trådløse enheder er svagt. 1.3 Fagudtryk Du vil få en bedre forståelse af systemets virkemåde, hvis du læser definitionerne i ordbogen i APPENDIKS A. Hvis du er bekendt med brugen af alarmcentraler, kan du blot fortsætte herfra. 1.4 Symboler anvendt i vejledningen Symbol Betydning Tryk på tast: Tryk på den tast, som fingeren peger på eller indtast de cifre, som fingeren peger på. Sikkerhedskode: fra fabrikken. Fejl: fejl melodi ( ). Succes: succes melodi ( ). Enkelt bip ( - ): Optræder ved ethvert tastetryk!! Dobbelt bip (- -): Indikerer automatisk tidsudløb. Tredobbelt bip (- - -): En gang pr. minut indikerer system problem. Buzzer alarm: buzzer lyder kontinuerlig. Advarsel om indgangs-/udgangsforsinkelse: Langsomme bip i starten ( ) og hurtige bip i de sidste 10 sekunder ( ). Blinkende markør. Indikator tændt: Den indikator, som er nævnt i forbindelse med symbolet, er tændt. Indikator blinker: Den indikator, som er nævnt i forbindelse med symbolet, blinker. Indikator slukket: Den indikator, som er nævnt i forbindelse med symbolet, er slukket. Meddelelse udtales via højttaleren 1.5 Taster på alarmcentralen Når dækslet til tastaturet er lukket, som vist i figur 1, er alene de 2 taster på alarmcentralen synlige: Tast Opgave Skift fra et punkt til et nyt punkt i en given menu. Se statusrapport en efter en, eller vælg den viste mulighed. Når tastaturdækslet er åbnet (se figur 4), vil de specielle funktionstaster være synlige. Tasternes funktion forklares neden for i de relevante afsnit. 1.6 Multifunktions håndsender Systemet reagerer på signaler sendt fra 4-tasthåndsenderen (MCT- 234), som du og andre brugere har. De enkelte tasters funktion er angivet i figur 3. Montøren kan programmere ekstrataster til at udføre en række opgaver, som du vælger. Figur 3. Håndsender DD5467U 5
54 A. Styring af garageport eller andre elektriske enheder: Et tryk på EKSTRA-tasten kan åbne/lukke en elektrisk styret garageport eller en anden elektrisk enhed i din virksomhed eller hjem. B. Straks tilkobling af alarmcentralen (uden indgangsforsinkelse): Tastes EKSTRA knappen straks efter tilkoblingen, mens udgangsforsinkelsen er i gang, vil alarmcentralen blive tilkoblet uden indgangsforsinkelse. Dette betyder, at indgang i det sikrede område straks vil udløse alarmen. Alarmcentralen kan frakobles af dig og de øvrige brugere ved at trykke på tasten FRAKOBLING ( ) på håndsenderen, før du går ind i det sikrede område. C. Indhente statusoplysninger: Ved et tryk på EKSTRA knappen på håndsenderen vil talemodulet meddele dig systemets status via højttaleren. Frakobling med håndsender hvis batteri er svagt Ved frakobling af systemet med en håndsender hvis batteri er svagt, vil centralen afgive et lavt problem bip i 15 sekunder, som tegn på, at håndsenderens batteri er svagt. Brugeren skal nu igen trykke frakobling på håndsenderen, eller trykke HOME og brugerkode på centralen, for at frakoble centralen. Udføres kvittering inden for de 15 sekunder, vil svagt batteri hændelsen gemmes i loggen. Hvis frakobling ikke udførtes igen inden for de 15 sekunder, gør da et af følgende: A: Tryk AWAY to gange for at tilkoble system, ellers vil centralen ikke tilkobles og kvitteringen vil ikke gemmes i loggen. B: Tryk AWAY og derefter HOME for at kvittere for svagt batteri meddelelsen. 1.7 Tale meddelelser PowerMax+ s talemodul hjælper dig med at betjene systemet, når du er tæt på centralen, samt ved fjernbetjening via telefonen. De indtalte beskeder reagerer på dine kommandoer ved at meddele, hvad systemet foretager sig og anmoder dig om at udføre visse handlinger. Den meddeler ligeledes alarm og problem meddelelser og identificerer hvor alarmen/problemet kommer fra. De forud indtalte meddelelser, der genereres af talemodulet, er klare og selvforklarende. Derfor er disse talemeddelelser undladt i vejledningen i stedet er koncentrationen rettet mod det visuelle display, og de akustiske signaler (bip). Herved bliver vejledningen kortfattet, men samtidig præcis. LCD DISPLAY TIL INDIKATOR PROBLEM INDIKATOR PowerMax+ Alarmcentral KLKE INDIKATOR POWER INDIKATOR VIS / Skru op for lyd Afspil meddelelse Skru ned for lyd Dørklokke til/fra Afbryd højttaler STRAKS tilkobling Begivenhedsjournal Indtal meddelelse Tænd lys Fuld tilkobling Sluk lys Nattilkobling Lyskontrol Flakobling Test Et menupunkt tilbage NØDKALD (Tryk i 2 sek.) BRAND (Tryk i 2 sek.) Tryk begge knapper for Panikalarm Figur 4. Tastatur, knapper og LED indikering. Bemærk, vedrørende Afbryd højttaler tasten Afbryd højttaler tasten er kun aktiv hvis der i "Sæt tale menu" er valgt Tale Til. (se brugeropsætning, fig. 8). 6 DD5467U
55 1.8 Screen Saver funktion Efter 30 sekunder hvor der ikke er trykket på nogen tast, indsættes navnet PowerMax som screen saver, og samtidig slukkes for indikerings LED erne (for at forhindre en eventuel indbrudstyv i at se systemets status). Det kan vælges om normalt display og LED visning skal retableres efter tryk på en hvilken som helst tast (Opdater ved tast), eller om det skal gøres ved at taste OFF knappen efterfulgt af bruger koden. (Opdater ved kode). Hvis Opdater ved tast er valgt, vil den første tast der røres (undtaget Brand og Nødkald) opdatere displayet og næste tryk vil udføre tastens funktion. Brand og Nødkalds tasterne vil ved første tryk, både retablere almindelig visning OG udføre tasternes funktion. 2. SIKRING AF DET BESKYTTEDE OMRÅDE 2.1. Sikkerhedsrelaterede taster Tast Funktion Fuld tilkobling - når ingen er hjemme Nat tilkobling når nogle personer er hjemme Annullering af udgangsforsinkelse ved tilkobling (STRAKS-FULD TILKOBLING eller STRAKS-NAT TILKOBLING) Frakobling af system samt stop af alarm Test af system (se afsnit 6.7). 2.2 Forberedelse af tilkobling Før tilkobling skal du sikre dig, at displayet viser: KLAR TT:MM Hvis displayet viser KLAR, er alle zoner lukket, og du kan tilkoble systemet, som du ønsker. Hvis en eller flere zoner er åben (forstyrret), eller hvis der har været en alarmhændelse, og Montør Reset / Kodet Reset funktion er valgt af montøren, vil displayet vise: IKKE KLAR TT:MM Procedure efter alarm ved: Montør Reset: Systemet skal resættes af en montør, før det igen kan tilkobles. Kodet Reset: Et blinkende ANGIV KODE: xxxxx vises i displayet. Brugeren skal nu ringe kontrolcentralen op og angive den viste kode, hvorefter Vagten vil udlevere en Reset kode. Brugeren skal nu trykke NEXT og indtaste den modtagne kode. Displayet vil nu vise KLAR. Hvis displayet viser IKKE KLAR, tast for at se nummer og navn på de åbne zoner, en efter en. Forestil dig, at zone 4 (bagdør) og zone 9 (køkken) er åbne. For at undersøge disse zoner fortsæt således: IKKE KLAR TT:MM BAGDØR Z4 (skiftende mellem) KØKKEN ÅBEN (skiftende mellem) Z9 ÅBEN Se bemærkning (efter 10 sekunder) nedenfor IKKE KLAR TT:MM Bemærk: Tryk for at afslutte når som helst Det anbefales, at de åbne zoner lukkes således, at systemet bliver klar til tilkobling (displayet viser KLAR). Kontakt montøren, hvis du ikke ved, hvordan dette skal gøres. VIGTIGT! Tilkoblingsprocedurerne forklarede i det følgende, er baserede på, at montøren i systemopsætningen har valgt STRAKS TILKOBLING. Hvis STRAKS TILKOBLING ikke er valgt, vil PowerMax anmode om indtastning af sikkerhedskode, før tilkobling kan ske. 2.3 Fuld tilkobling AWAY Hvis displayet viser KLAR, fortsæt således: TILKOBLET FORLAD OMRÅDET Forlad lokalet (Udgangsforsinkelse)!! TILKOBLET TIL indikatoren lyser under tilkoblingsperioden 2.4 Nat Tilkobling HOME Hvis alle perimeterzoner er KLAR og Straks Tilkobling er valgt, fortsæt således: NAT TILKOBLING Gå til indvendig zone (Udgangsforsinkelse)!! NATTILKBL.TT:MM TIL indikatoren blinker under tilkoblingsperioden 2.5 Skift fra Nat Tilkobling til Fuld Tilkobling. Du behøver ikke at frakoble systemet tast blot. Reaktionen vil være den samme som beskrevet i afsnit 2.2. Forlad lokalet før udgangsforsinkelsen udløber. 2.6 Skift fra Fuld Tilkobling til Nat Tilkobling Du behøver ikke at frakoble systemet tast blot. Da denne funktion reducerer sikkerhedsniveauet, vil PowerMax+ anmode dig om indtastning af superbruger-/ brugerkode for at sikre, at du er autoriseret bruger. [] KODE NAT TILKOBLING Gå til indvendig zone (Udgangsforsinkelse)!! NATTILKBL.TT:MM TIL indikatoren blinker under tilkoblingsperioden Hvis der har været aktiveret en alarm under den fulde tilkoblingsperiode, vil reaktionen være en anden, nemlig: DD5467U 7
56 KODE [ ] NATTILK.HUKOM. Gå til indvendig zone (Udgangsforsinkelse)!! NATTILKBL.TT:MM (skiftende mellem) NATTILK.HUKOM. TIL indikatoren blinker under tilkoblingsperioden 2.7 Straks Tilkobling Du kan foretage såvel Fuld Tilkobling (AWAY) som Nat Tilkobling (HOME) uden indgangsforsinkelse enhver detektering i en af zonerne vil straks udløse en alarm. Hvis du ønsker at foretage Straks Fuld Tilkobling, fortsæt da således: TILKOBLET TILK.U/FORSINK. (skiftende mellem) FORLAD OMRÅDET Forlad området (Udgangsforsinkelse)!! TILKOBLET TIL indikatoren lyser under tilkoblingsperioden Hvis du ønsker at foretage straks nat tilkobling, fortsæt da således: NAT TILKOBLING TILK.U/FORSINK. (skiftende mellem) NAT TILKOBLING Gå til en indvendig (Udgangsforsinkelse)!! zone NATTILKBL.HH:MM (skiftende mellem) NATTILK.U/FORS. TIL indikatoren blinker under tilkoblingsperioden 2.8 Tvungen Tilkobling Tvunget tilkobling giver mulighed for at tilkoble systemet, selv om en eller flere zoner er åbne (forstyrrede), og systemet viser IKKE KLAR i displayet. Automatisk tvunget tilkobling fungerer kun, hvis montøren har tilladt dette under programmeringen af systemet. Forstyrrede zoner vil blive isoleret og således ikke reagere på detekteringer. Det sikrede område er ikke sikret optimalt. Bemærk: Når tvungen tilkobling udføres, vil buzzeren indikere dette ved at afgive en kontinuerlig tone under udgangsforsinkelsen, indtil de sidste 10 sekunder af forsinkelsen. Du kan gøre buzzeren tavs ved at taste samme tast endnu engang. Når IKKE KLAR vises i displayet, kan tvungen tilkobling AWAY foretages således: (for at gøre buzzeren tavs) TILKOBLING FORLAD OMRÅDET (Udgangsforsinkelse) TILKOBLET TIL indikator lyser under tilkobling Når IKKE KLAR vises i displayet, kan tvungen nat tilkobling AWAY foretages således: (for at gøre buzzeren tavs). Gå til en indvendig zone NAT TILKOBLING (udgangsforsinkelse) NATTILKBL.TT:MM TIL indikatoren blinker under tilkoblingsperioden 2.9 Tilkobling m/frakoblingsrapport Denne funktion kan anvendes af forældre på job som ønsker at vide, hvornår børnene kommer hjem fra skolen og frakobler systemet. Systemet afgiver en speciel Frakoblingsrapport, når systemet frakobles af brugere med koderne fra 5 til 8 eller håndsenderne 5 til 8. Meddelelsen er tænkt som en information og ikke som en alarm, og sendes derfor til private telefoner, som er programmeret hertil. Tilkobling m/frakoblingsrapport er kun mulig når der tilkobles fuldt, AWAY : TILKOBLING TILK. M/RAPPORT (indenfor 2 sek.) (skiftende mellem) FORLAD OMRÅDET Forlad lokalet (Udgangsforsinkelse)!! TILKOBLET TIL indikator lyser under tilkobling 2.10 Udløse en Panik Alarm Du udløser panikalarmen manuelt på samme måde uanset om alarmcentralen er Til eller Frakoblet. Hvis denne funktion er slået TIL i opsætningen, er sekvensen som følger: (trykkes ned samtidig) PANIK ALARM Herefter, når systemet er frakoblet: KLAR TT:MM (skiftende mellem) KLAR HUKOMMELSE Sirene Bemærk: Hvis du anvender en håndsender, tryk da både TILKOBLING (AWAY) og NAT TILKOBLING (HOME) tasterne samtidig, og hold dem nede i 2 sekunder). For at stoppe alarmen, tryk, og brugerkode. 8 DD5467U
57 2.11 Frakoble og afbryde Alarm Frakobling af systemet, afbryder sirenen før den automatisk udløber. Dette vil ske, uanset om alarmen er udløst, mens systemet er tilkoblet eller frakoblet. Efter frakobling, kan der fremkomme forskellige oplysninger i displayet afhængig af den aktuelle status på systemet: A. Frakobling ingen begivenheder: Efter en tilkoblingsperiode uden hændelse vil frakoblingen foregå således: INDTASTKODE [] KLAR TT:MM TIL Indikator slukker B. Frakobling efter alarm, når alle zoner er klar: Hvis zonen, der afgav alarm, er tilbage i normal status, vil frakoblingen forløbe således: INDTASTKODE [] KLAR TT:MM (skiftende mellem) KLAR HUKOMMELSE TIL Indikator slukker For at aflæse alarmhukommelsen henvises der til afsnit 5. Hukommelsesmeddelelsen vil blive slettet, når systemet atter tilkobles. C. Frakobling efter en alarm, når en zone stadig er forstyrret: Hvis zonen, der har afgivet alarm, i den seneste tilkoblingsperiode stadig er forstyrret, vil frakoblingen forløbe således: INDTAST KODE [] IKKE KLAR HH:MM (skiftende mellem) IKKE KLAR HUKOM. TIL Indikator lyser For at aflæse alarmhukommelsen henvises der til afsnit 5. Hukommelse meddelelsen HUKOMMELSE. vil blive slettet, når systemet atter tilkobles. Kontakt montøren, hvis du ikke ved, hvordan forstyrrede zoner bringes tilbage til normal status. D. Frakobling af systemet mens systemet er i problemstatus: Hvis der er konstateret problemer, vil PROBLEM indikatoren lyse, og frakoblingen vil forløbe således: INDTASTKODE [] KLAR TT:MM TIL slukker og KLAR (skiftende mellem) PROBLEM lyder en gang i minuttet For at finde ud af hvilket problem, der er konstateret, henvises til afsnit 5. PROBLEM meddelelse i displayet forsvinder, PROBLEM indikatoren slukkes og buzzeren vil ophøre med at afgive problem-bip, når problemet er lokaliseret og udbedret. E. Frakobling efter alarm, mens systemet er i problemstatus: Problem indikatoren på frontpanelet lyser. Hvis den zone, der afgav alarm under seneste alarmperiode, atter er tilbage i normal (ikke forstyrret), vil frakobling forløbe således: INDTASTKODE [] KLAR TT:MM (skiftende mellem) TIL Lyser og KLAR PROBLEM (skiftende mellem) KLAR HUKOMMELSE lyder en gang i minuttet For at finde ud af hvilken zone, der afgav alarm, og hvilken form for problem, der er blevet detekteret, se afsnit 5. Når årsagen til problemet udbedres, vil PROBLEM meddelelsen i displayet forsvinde, Problem indikatoren vil slukke, og problem bippene stoppe. Først når systemet atter tilkobles, vil HUKOMMELSE meddelelsen i displayet forsvinde. F. Frakobling under tvang (overfaldsalarm): Hvis du tvinges til at frakoble systemet, indtast da den specielle overfaldskode, som er Frakobling vil ske som normalt, men alarmcentralen afgiver en tavs alarm til kontrolcentralen Sirene virkemåde Sirenen vil lyde forskellig afhængigt af situationen. Kontinuerlig AKTIV når alarmen er aktiveret i en indbruds zone eller en 24-timers zone, og når brugeren aktiverer en panik alarm. AKTIV - AKTIV - AKTIV - pause - AKTIV - AKTIV - AKTIV - pause -... osv., når en brandzone aktiveres (der er detekteret røg). Hvis der ikke er personer tilstede, der er autoriserede til at frakoble systemet efter en alarm, og en zone forbliver forstyrret, vil alarmen lyde i en periode, hvis længde afhænger af montørens programmering. Efter 30 sekunders tavshed vil alarmen blive genaktiveret i samme tidsperiode. Denne alarm cyklus vil gentage sig, indtil det maksimalt tilladte antal (programmeret af montøren). Den forstyrrede zone vil herefter blive isoleret (frakoblet), og sirenen vil stoppe. Dette vil også ske for alarmer aktiveret af brand eller en 24-timers zone, når systemet er frakoblet. En zone isoleret (frakoblet) via AFBRYD ZONE bliver automatisk genetableret ved næste frakobling eller tilkobling (afhængig af systemets status, mens alarmen blev udløst). DD5467U 9
58 3. TALE OG LYD BETJENING 3.1 Taster til betjening af tale og lyd PowerMax+ har en række lyd- og talerelaterede funktioner, som betjenes via tastaturet, beskrevet i følgende skema: Tast Funktion Forøg lydstyrken af talebeskeder. Reducer lydstyrken af talebeskeder. Tilkobling / frakobling af højttaleren. Indtal en besked til andre brugere af alarmsystemet. Aflyt en besked indtalt af en anden bruger af alarmsystemet. Tilkobling / frakobling af dørklokkefunktion. 3.2 Justering af lydstyrken Følgende diagram viser, hvordan lydstyrken øges ved at taste <1> (forudsat at lydstyrken er lavere end maksimum før den forøges). (max) VOLUME+ VOLUME+ VOLUME+ VOLUME+ Følgende diagram viser, hvordan lydstyrken reduceres ved at taste <4> (forudsat at lydstyrken er højere end minimum før den reduceres). (max) VOLUME VOLUME VOLUME VOLUME 3.3 Tale TIL/FRA Du kan vælge om stemme-/talefunktionen skal være TIL eller FRA ved gentagne tastetryk på <7>, som vist nedenfor: TALE TIL TALE FRA KLAR TT:MM Bemærk: Systemet vil opretholde TALE FRA mode, indtil der vælges TALE TIL. 3.4 Indtal en besked Du kan efterlade en verbal besked til andre brugere af alarmsystemet. Hold tasten nede. Når displayet viser, TAL NU, start indtaling. De 5 mørke felter forsvinder langsomt en efter en, fra højre mod venstre, som vist i diagrammet nedenfor: (konstant) INDTAL BESKED Tal TAL NU Ingen Tal TAL NU Tal TAL NU Tal TAL NU Tal TAL NU Stop indtaling INDTALING SLUT Når det sidste mørke felt forsvinder (20 sekunder senere), dukker meddelelsen INDTALING SLUT op i displayet. Når du slipper tasten, vil displayet vende tilbage til normal status (KLAR), men vil derudover indikere, at der venter en besked. F.eks.: KLAR (skiftende mellem) KLAR TT:MM BESKED For at checke din egen besked, aflyt den inden der er gået et minut fra afslutningen af indtalingen (se afsnit 3.5). På denne måde bliver BESKED meddelelsen på displayet ikke slettet. 3.5 Afspil Besked For at afspille en besked indtalt af en anden bruger: Tast og lyt. AFSPILLER vil blive vist i displayet og beskeden bliver afspillet via den indbyggede højttaler. Når afspilningen er afsluttet, vil displayet vende tilbage til normal status. Hvis der er gået mere end 1 minut siden beskeden blev indtalt, når den høres, vil BESKED indikeringen forsvinde. 3.6 Dørklokke TIL/FRA Du kan tilkoble (TIL) eller frakoble (FRA) dørklokkezoner, ved gentagne tryk på <8> tasten, som vist nedenfor: DØRKLKE TIL DØRKLKE FRA KLAR TT:MM KLKE lyser når DØRKLKE TIL er valgt 10 DD5467U
59 4. STYRING AF ELEKTRISKE ENHEDER 4.1 Styringsmuligheder og taster PowerMax+ giver mulighed for manuel eller automatisk fjernbetjening af op til 15 elektriske enheder (lys, radio, TV, kaffemaskine osv.). Dette kræver en særskilt X-10 PowerLine Adapter og op til 15 fjernbetjente X-10 enheder (se figur 2). PowerLine adapteren konverterer Tænd og Sluk styringskoderne der afgives af PowerMax+, til signaler der kommunikeres via det almindelige 230V ledningsnet. Udover X-10 enhederne (fra nr. 1 til nr. 15), er det muligt at styre en enhed der er forbundet til PGM udgangen (enhed nr. 00). Under programmering af systemet afgør montøren TÆND og SLUK timeren for hver af de fjernbetjente enheder. Han afgør også, hvilke zonedetektorer der tænder og slukker den styrede enhed. Afgørelsen af hvordan de fjernbetjente elektriske enheder skal reagere på programmeringen er op til dig. (se nedenstående tabel). Tast Funktion Manuel TÆND, lys eller andre elektriske husholdningsenheder. Manuel SLUK, lys eller andre elektriske husholdningsenheder. Vælg den automatiske styring: Sensor: Enheden styres af en detektor (konfigureres af montøren for dette). Timer: Enheden styres af en timer (TÆND og SLUK tiderne defineres af montøren). Begge: Enheden styres af sensor OG timer. Følgende er to eksempler på anvendelsen af automatisk fjernbetjening til forbedring af sikkerheden: Timerstyring. Når du ikke er hjemme, kan tændt lys, radio eller TV få hjemmet til at se ud, som om der er personer i hjemmet og derved forebygge potentielle indbrud. Zonestyring. Ved forstyrrelse af en perimeterzone kan lyset tændes, og en enhed kan afspille et lydspor med hunde, der gør. 4.2 Manuel Tænd af enheder Du kan TÆNDE enheden manuelt som angivet nedenfor. Dette eksempel viser hvordan lys tændes af X-10 enhed nr. 1. TÆND LYS TÆND LYS 1 KLAR TT:MM Lys, som styres af X-10 enhed nr. 1 tændes 4.3 Manuel Sluk af enheder Du kan SLUKKE enheden manuelt som angivet nedenfor. Dette eksempel viser, hvordan lys slukkes af X-10 enhed nr. 1. SLUK LYS SLUK LYS 1 KLAR TT:MM Lys, som styres af X-10 enhed nr. 1 slukkes 4.4 Lys dæmp/forøg Straks efter at lyset er blevet tændt (se afsnit 4.2), kan du dæmpe eller forøge lys mængden som ønsket. For at gøre dette, aktiveres Dæmp/Forøg funktionen ved at trykke eller, tryk derefter (som ønsket) på (Dæmp) eller på (Forøg) knappen flere gange indtil ønskede lysstyrke er opnået. 4.5 Automatisk Tænd/Sluk styring Du kan vælge to af følgende 4 muligheder: TIMER TIL TIMER FRA SENSOR TIL SENSOR FRA De aktuelt valgte muligheder er markeret med en mørk boks ( ) i højre side. Du kan gennemse de to øvrige muligheder ved at taste <9>. De muligheder, som ikke aktuelt er valgt, er angivet uden en mørk boks i højre side. Den mørke boks dukker op, hvis du taster <>, mens muligheder angives i displayet. repræsenterer succesmelodien det nye valg er gemt i hukommelsen. Hvis du ikke ønsker denne - Hvis denne ønskes - Hvis du ikke ønsker denne - Hvis denne ønskes - TIMER TIL (hvis denne aktuelt er valgt) TIMER FRA TIMER FRA TIMER FRA SENSOR TIL (hvis denne aktuelt er valgt) SENSOR FRA SENSOR FRA SENSOR FRA KLAR TT:MM DD5467U 11
60 5. AFLÆS ALARMHUKOMMELSE OG PROBLEMOPLYSNINGER 5.1 Genkald indhold af alarm- og sabotage hukommelse PowerMax+ gemmer de alarm- og sabotagehændelser, som er opstået under den seneste tilkoblingsperiode, i hukommelsen. Bemærk: Det er kun de alarmer, der udløses efter udløb af afbrydningsperioden (se Appendiks A), der bliver gemt i hukommelsen. Dette betyder, at hvis du frakobler systemet straks før udløbet af afbrydningsperioden vil der ikke blive vist en HUKOMMELSE meddelelse. A. Alarm/sabotage indikator Hvis hukommelsen indeholder mindst en begivenhed, og systemet er frakoblet, vil displayet vise en blinkende HUKOMMELSE meddelelse: KLAR (skiftende mellem) TT:MM KLAR HUKOMMELSE Eller, hvis systemet ikke er klar til tilkobling: IKKE KLAR TT:MM (skiftende mellem) IKKE KLAR HUKOM. B. Undersøg alarm-/sabotageoplysninger Du kan genkalde indholdet af hukommelsen ved at trykke på VIS/ tasten. EKSEMPEL 1: En alarm var udløst fordi garagedøren zone nr. 3 var åbnet og atter lukket igen. Ligeledes har soveværelsedetektoren zone nr. 12 afgivet en SABOTAGE alarm, idet kabinettets front er blevet fjernet. KLAR TT:MM Z03 I ALARM (skiftende mellem) GARAGEDØR Z12 SABOTAGE (skiftende mellem) SOVEVÆRELSE Hvis du trykker på <VIS/> tasten igen, vil displayet vise enten nærmere detaljer om hændelsen, næste hændelse i hukommelsen (hvis der er nogle), eller vende tilbage til første statuspunkt (se A ovenfor). EKSEMPEL 2: En alarm var udløst, fordi garagedøren zone nr. 3 er åbnet og efterladt åben. IKKE KLAR TT:MM Z03 I ALARM (skiftende mellem) GARAGEDØR Z03 ÅBEN (skiftende mellem) GARAGEDØR Husk! Hukommelsesindikationen og indholdet bliver slettet ved næste tilkobling af systemet. 5.2 Genkald problemoplysninger A. Problem indikatorer Hvis PROBLEM blinker i displayet, problem indikatoren lyser og 3 bip lyder en gang i minuttet, bør du undersøge systemet for at finde kilden og typen af problemet. Problemerne kan deles op i følgende systemdele: DETEKTOR, HÅNDSENDER og TRÅDLØST TASTATUR Detektor inaktiv PowerMax har ikke modtaget signal fra en given detektor indenfor en foruddefineret periode. Svagt batteri Batteriet i en trådløs enhed (detektor eller håndsender) er svagt. Rengør detektor En Røgdetektor skal rengøres. Gas fejl - Gas detektor fejl. Sirene strømsvigt Der er ikke spænding på sirenen. X-10 fejl - En aktiveringskommando blev sendt til en 2- vejs X-10 enhed, men en bekræftelse på kommandoens udførelse blev ikke modtaget fra enheden. GSM Fejl (hvis GSM er i brug) GSM Strømsvigt - Ingen spænding på GSM enhed. GSM svagt batt. - GSM batteriet er svagt. GSM sabotage - GSM enheden er blevet taget af væggen eller åbnet. GSM linie fejl - GSM telefonliniefejl. GSM net fejl - GSM netværksfejl. GSM RSSI low - GSM signalet er svagt. GSM modem fra - GSM enheden er ikke operativ. GSM kommunikations fejl Der er ikke kommunikation (RS-232) mellem PowerMax+ og GSM enheden. SYSTEMPROBLEMER AC strømforsyningsfejl - Strømforsyningen via ledningsnettet er blevet afbrudt, og systemet forsynes alene af backupbatteriet. System jam - et RF signal blokerer kanalen, som anvendes af en detektor tilsluttet alarmcentralen. Kommunikationsfejl - En meddelelse kan ikke sendes til kontrolcentralen eller en privat telefon (eller en besked var afsendt, men ikke accepteret/ bekræftet). Central sabotage - Centralen er taget ned af væggen eller er blevet åbnet. Central svagt batteri - Backupbatteriet inde i alarmcentralen er svagt og skal udskiftes (se afsnit. 9.1). Sikringsproblem - sikringen er sprunget. VIGTIGT! Hvis problembippene generer dig, frakobl systemet (selv om det allerede er frakoblet). Dette vil annullere problembippene i 4 timer. B. Undersøg årsagen til problemet Når der er konstateret et problem, vil displayet vise en blinkende PROBLEM meddelelse: KLAR TT:MM (skiftende mellem) KLAR PROBLEM Eller, hvis systemet ikke er klar til tilkobling: IKKE KLAR TT:MM (skiftende mellem) IKKE KLAR PRBL. 12 DD5467U
61 Du kan genkalde problemerne et efter et ved tryk på VIS/ tasten. EKSEMPEL: Detektoren i køkkenet zone nr. 9 er inaktiv og detektoren i dagligstuen zone nr. 11 har rapporteret om svagt batteri. Disse problemer vil imidlertid ikke afholde systemet fra at være KLAR til tilkobling. For at undersøge årsagen til problemet, fortsæt således: KLAR TT:MM Z09 INAKTIV (skiftende mellem) KØKKEN Z11 SVAGT BAT. (skiftende mellem) DAGLIGSTUE Hvis du trykker på <VIS/> tasten igen, vil displayet vise enten nærmere detaljer om andre problemer i hukommelsen (hvis der er nogle), eller vende tilbage til første skiftende skærmbillede (se ovenstående eksempel). 5.3 Visning af Hukommelse og Problemoplysninger samtidigt Hvis der er gemt alarm-/sabotagebegivenheder i alarmhukommelsen samtidig med at systemet er i problem status, vil displayet vise følgende: KLAR (skiftende mellem) TT:MM KLAR HUKOMMELSE KLAR (skiftende mellem) PROBLEM Eller, hvis systemet ikke er klar til tilkobling: IKKE KLAR (skiftende mellem) TT:MM IKKE KLAR HUKOM. (skiftende mellem) IKKE KLAR PRBL. Bemærk: Hvis der er en talebesked i hukommelsen, vil displayet også vise BESKED (som vist i afsnit 3.4). 6. SPECIELLE FUNKTIONER 6.1 Holde opsyn med personer i hjemmet En vigtig egenskab ved PowerMax+ er dens evne til at fungere modsat af, hvordan et alarmsystem normalt fungerer. Når systemet er frakoblet (eller selv Nat tilkoblet HOME kun med perimeterbeskyttelse), kan den registrere aktivitet i huset og afgive rapport om manglende bevægelse i indvendige zoner, hvis der ikke detekteres bevægelse inden for den programmerede tidsperiode. For at anvende denne funktion, skal du bede montøren om at programmere en specifik tidsperiode, indenfor hvilken manglende bevægelse vil blive rapporteret som ikke aktiv alarm. For at illustrere dette kan du forestille dig, at en ældre, syg eller handicappet person skal efterlades uden opsyn inde i den beskyttede ejendom. For at aflæse statusinformationer hukommelsesoplysninger, åbne zoner og problemårsager (i denne rækkefølge) - tryk på <VIS / > tasten gentagne gange. Indholdet af hukommelsen vil blive angivet i displayet først på samme måde, som vist i afsnit 5.1. Hvis systemet ikke er klar, vil information om åbne zoner foregå på samme måde, som angivet i afsnit 2.2. Problemårsager vil blive vist til sidst på samme måde som angivet i afsnit Udbedring af problemer Problemindikatorerne (PROBLEM lyser og i displayet blinker PROBLEM meddelelse) bliver slettet, når du har udbedret årsagen til problemet. Kontakt montøren, hvis du ikke er klar over, hvordan du udbedrer problemet. INAKTIVITET: Når en inaktiv detektor eller trådløs fjernbetjening genoptager sine periodiske transmissioner, vil der ikke længere være et inaktivitetsproblem og derfor ingen indikering på alarmcentralen. SVAGT BATTERI: Når batteriet udskiftes i en trådløs detektor, håndsender eller fjernbetjening, som har afgivet et signal om svagt batteri, vil næste transmission, som afgives af detektoren, inkludere en meddelelse om batteri-strømforsyning genoprettet, og svagt batteri vil ikke længere blive indikeret af alarmcentralen. SYSTEM PROBLEM: Udbedring af et hvilket som helst problem i systemet vil automatisk blive konstateret af alarmcentralen, og problemindikationen slettes. Denne person vil, uanset sygdom eller invaliditet, ikke ligge/forholde sig helt stille i flere timer. Selv om man sover, vil man naturligt vende sig i sengen fra tid til anden. Personen vil måske også gå i køkkenet for at spise eller drikke, eller til badeværelset for øvrige nødvendigheder. Når dette sker, vil detektorerne i soveværelset, badeværelset og køkkenet detektere bevægelserne. Hvis f.eks. manglende bevægelse tidsperiode er indstillet til 6 timer af montøren, vil en nedtælling på 6 timer påbegyndes. Hvis bevægelse detekteres indenfor 6-timers rammen, vil nedtællingen starte forfra igen (6-timers nedtælling vil blive resat ) og der vil ikke blive afgivet en alarmrapport. Hvis ingen bevægelse detekteres indenfor 6-timers rammen i en hvilken som helst indvendig zone, vil alarmcentralen afgive en ikke aktiv alarmrapport til kontrolcentralen eller til private telefoner, afhængig af montørens opsætning. DD5467U 13
62 VIGTIGT! Herudover kan du udstyre en sengeliggende person med en håndsender til brug i nødsituationer se afsnit Nødkald efter hjælp Hvis en person som nævnt i afsnit 6.1 kommer ud for et uheld, så som at glide i badekarret uden at være i stand til at komme op. Det kan tage flere timer før ikke aktiv alarmen bliver afgivet, men personen har brug for assistance hurtigt. Selv om risikoen for en sådan ulykke er lille, anbefales det at udstyre sådanne personer med en håndsender, som kan bæres om halsen eller håndleddet som et ur. Trykkes der på knappen på håndsenderen, vil PowerMax afgive et nødkald til kontrolcentralen eller til private telefoner, afhængig af montørens opsætning af systemet. For at gøre brug af denne egenskab, skal du bede montøren om at definere en af de 28 zoner på PowerMax+, som en nødkaldszone, der tilknyttes en af nedennævnte håndsenderes ID koder. De modeller, som er kompatible med PowerMax er (fig. 5): MCT-201 Smykkesender MCT-211 Armbåndssender MCT-101 Lommesender MCT-201 MCT-211 MCT-101 Figur 5. Nødkaldssendere 6.3 Fjernbetjening via telefon PowerMax+ alarmcentral A. Etablering af Telefonkommunikation Ved kommunikation med PowerMax+ systemet fra en almindelig telefon kan en lang række funktioner udføres: Tilkobling og frakobling, tænd og sluk af elektriske enheder og PGM udgangen, optage, afspille og slette tale beskeder samt undersøge system status. Forløbet er vist nedenfor: 1. Ring til nummeret hvor PowerMax+ befinder sig. 2. Vent i 2-4 ring og læg på. 3. Vent sekunder. 4. Ring igen til PowerMax+ tlf. Nr. PowerMax+ vil svare og en hyletone vil lyde i 10 sekunder Trin 2-4 springes over ved opkald til GSM nummeret til PowerMax+. Gå direkte til trin [*] (for at stoppe tonen) 6. [bruger kode], [#] 7. [ønskede kommando, se tabellen nedenfor] Bemærk: Hvis du tøver i mere end 50 sekunder uden at indtaste en kommando, vil PowerMax+ afbryde forbindelsen. B. kommandoer som kan udføres Kommando Frakobling Nat tilkobling Nat tilkobling, Straks Tilkobling Tilkobling, Straks Tilkobling, m/frakobl rapport Tilkobling, Straks, m/frak. Rap. Elektr. enhed (Nr ) TIL Elektr. Enhed (Nr ) FRA Aktivering af PGM udgang Indtastningssekvens [][1][#] [][2][#] [][2][1][#] [][3][#] [][3][1][#] [][4][#] [][4][1][#] [][5][enhed Nr.][1] [#] [][5][enhed Nr.][0] [#] [][5][0] [0][1][#] Kommando Deaktivering PGM udgang To-vejs tale kommunikation (se afsnit C nedenfor) Afspil indtalt besked Start indtaling af besked Stop indtaling af besked Slet indtalt besked Undersøg system status Afslut (afbryd kommunikation) Indtastningssekvens [][5][0] [0][0][#] [][7][#] [][8][1] [#] [][8][2] [#] [][8][3] [#] [][8][4] [#] [][9][#] [][9][9][#] C. To-vejs tale kommunikation Udfør trin 1-6 i afsnit 6.3A og fortsæt som følger: 1. [][7][#] 2. Vent på 2 bip 3. [3] eller [1] eller [6] (se nedenfor) Systemet vil åbne i "Lytte" funktion, som giver dig mulighed for at lytte i 50 sekunder. Tale, gråd og andre lyde vil kunne høres tydeligt. Du kan skifte mellem Lytte, Tale eller Fuld to-vejs tale som vist i tabellen: Kommando Tast Lytte (lytte til personen hjemme) (*) [3] Tale (tale til personen hjemme) (*) [1] Fuld to-vejs tale (samtidig lytte & tale) (*) [6] Bemærk: For at forlænge kommunikationen med 50 sekunder, tryk [3], [1] eller [6] igen, som ønsket. * Kommunikationen kan afsluttes ved at frakoble system. Bemærkning angående skiftevis Lytte og Tale Skiftevis Lytte & Tale (i modsætning til fuld to-vejs tale) frem og tilbage mellem to personer uden afbrydelser er en metode, som anvendes af militæret samt i kommerciel og amatør radio kommunikation. Når du er færdig med at tale, bør du sige gå i gang eller skifter og derefter skifte fra tale til at lytte. Når personen i hjemmet er færdig med at tale bør han også sige gå i gang eller færdig som tegn til dig om at skifte tilbage fra at lytte til tale mode. EKSEMPEL: Dig (ved telefonen): [1], Hej, George, kan du høre mig? Har du problemer? SKIFTER [3] Personen i hjemmet: Ja, jeg blev svimmel, da jeg forsøgte at forlade sengen og faldt om på gulvet. Jeg er ikke i stand til at rejse mig, og mine lår gør ondt. Kan du hjælpe mig? SKIFTER Dig (ved telefonen): [1], Selvfølgelig, jeg sender straks en af sted, forhold dig i ro - SKIFTER [3]. Person i hjemmet: Tak, men skynd dig, SKIFTER. Dig (ved telefonen): [1], O.K., SKIFTER OG FÆRDIG []9][9]. AFSLUTNING Vigtigt! Hvis du ønsker at afslutte to-vejs kommunikationsfunktionen og udføre en anden kommando, tryk da [] og indtast herefter brugerkoden efterfulgt af kommandoen (se indtastningssekvens i afsnit 6.3B). 6.4 Modtage meddelelse via telefon PowerMax+ alarmcentral PowerMax+ kan programmeres til at rapportere forskellige meddelelser til private telefoner. Meddelelserne er opdelt i tre grupper: Gruppe Rapporteret hændelse 14 DD5467U
63 1 Brand, indbrud, panik og sabotage 2 Tilkobling, Nat tilkobling og Frakobling 3 Ikke aktivitet, nødkald og Frakoblingsrapport. Gruppe 1 har højeste prioritet og gruppe 3 har laveste prioritet. Når den kaldte person besvarer et opkald foretaget af PowerMax, vil han høre en verbal meddelelse bestående af husets identitet og den type begivenhed, som er opstået. F.eks. når der detekteres røg i Schmidts ejendom, vil beskeden være: [Schmidts ejendom - brandalarm]. Hvis en person under opsyn i Nielsens ejendom har været inaktiv, vil meddelelsen være: [Nielsens ejendom ingen aktivitet]. Den person, som modtager opkaldet skal bekræfte meddelelsen (som forklaret i det følgende), hvis dette ikke sker, vil meddelelsen blive gentaget så mange gange som muligt indenfor 45 sekunder. Når der er gået mere end 45 sekunder, vil PowerMax afbryde forbindelsen og foretage opkald til næste private telefonnummer på listen. Personen kan bekræfte meddelelsen ved at trykke på en nummertast på telefonens tastatur, som beskrevet nedenfor: Kommando Tast Bekræfte alene: PowerMax+ afbryder 2 forbindelsen og betragter begivenheden som behørig rapporteret. Bekræfte og lytte: Det beskyttede område 3 aflyttes i 50 sekunder. Den kaldte person kan forlænge ved at trykke på [3] tasten igen før PowerMax+ afbryder forbindelsen, eller tast [1] for at tale. Bekræfte og tale: Den kaldte person kan tale i 50 1 sekunder til hvem, som måtte befinde sig i det beskyttede område. Den kaldte kan forlænge tale -tiden ved at taste [1] igen før PowerMax+ afbryder forbindelsen eller taste [3] for at lytte. Bekræfte og to-vejs tale: Du og den kaldte kan 6 tale og lytte samtidig uden at skulle skifte mellem "lytte" og "tale" funktion for 50 sek. (kan forlænges). Bekræfte og anmode om statusrapport: 9 PowerMax vil afgive en verbal rapport om systemets status. F.eks.: [Frakoblet klar til tilkobling] eller [Frakoblet bagdør åben] eller [Frakoblet - alarm i hukommelse]. 6.5 Fjernkontrol med SMS PowerMax+ systemet kan med en GSM enhed reagere på SMS kommandoer fra en mobil telefon. Dette forudsætter at FJERNBETJ. ADGANG TILLADT er indstillet af montøren. (Ref. PowerMax+ Programmeringsvejledning, afsnit Fjernbetj. Adgang). De forskellige SMS kommandoer er listet i nedenstående tabel (en detaljeret forklaring på afsendelse af SMS beskeder, kan findes i mobiltelefonens brugervejledning). I denne tabel, vil <kode> betyde den 4-cifrede brugerkode, og mellemrum betyder mellemrum. SMS kommando Liste Kommando SMS Format 1 Tilkobling TILKOBLING <kode> eller TILK <kode> 2 Straks Tilkobling TILK STRAKS <kode> eller 3 Tilkobling med Frakobl.Rapport 4 Tilkobling Straks med Frakobl.Rapport TS <kode> TILK RAP <kode> eller TR <kode> TILK RAP STR <kode> eller TRS <kode> 5 Nat Tilkobling TILK NAT <kode> eller TN <kode> 6 Nat Tilkobling TILK NAT STR <kode> eller TNS <kode> Straks 7 Frakobling FRAKOBLING <kode> eller FRAK <kode> 8 Tænd lys xx LYS xx TIL <kode> eller LS xx TIL <kode> (xx = 01 15) 9 Sluk lys xx (xx = 01 15) 10 Tænd PGM PGM TIL <kode> 11 Sluk PGM PGM FRA <kode> 12 Definer hus identitet (se note) 13 Send system status LYS xx FRA <kode> eller LS xx FRA <kode> HUS NAVN <kode> <hus ID> eller HN <kode> <hus ID> STATUS <kode> eller ST <kode> Note: Hus ID kan indeholde op til 16 karakterer, for eksempel: HANSEN SOMMERVEJ. 6.6 Rapportering med SMS Denne rapporteringsform er kun mulig hvis en GSM enhed er installeret. PowerMax+ kan sende SMS beskeder til op til fire (4) registrerede SMS telefoner. Registrering af SMS telefoner er forklaret i PowerMax+ programmeringsguide, afsnit 4.6). SMS beskederne er ganske tydelige og selvforklarende, og er derfor ikke yderligere forklarede I denne guide. Eksempler på de rapporterede SMS beskeder: HANSEN SOMMERVEJ **TILKOBLET** HANSEN SOMMERVEJ **FRAKOBLET** HANSEN SOMMERVEJ POWERMAX: SVAGT BATTERI GARAGE: SVAGT BATTERI Note Status beskeder kan kun sendes til en telefon hvis ID ikke er spærret af brugeren! 6.7 Rapportering til en Pager PowerMax+ alarmcentral M PAGER PowerMax kan programmeres til at afgive en hændelses rapport til en personsøger. Brugeren af personsøgeren skal informeres om, hvordan den numeriske meddelelse skal fortolkes. Kommunikation med en personsøger sker således: PowerMax foretager opkald til personsøgerens telefonnummer, venter 5 sekunder og sender derefter den numeriske meddelelse. Den meddelelse, som PowerMax afsender til personsøgeren, er en række cifre som eksemplificeret i figur 6 nedenfor. DD5467U 15
64 [XXXXXXXXXXXXXXXX] [YYY] [0ZZ#] Personsøgerens PIN-nr. - op til 16 cifre rogrammeret af montøren Hændelsestype Zonenr. Eller brugernr. Figur 6. Struktur i meddelelse til personsøger Den person, som modtager en meddelelse ser YYY - 00ZZ delen af meddelelsen, hvis betydning er anført i følgende skema: Begivenhedstype (YYY) er kodet som følger: Begivenhed Kode Begivenhed Kode Alarm 919 Brand 515 Problem 818 Til 101 Nødkald 717 Fra 102 Panik 616 Frakobl.rapp. 103 ZZ er zonenummer i hvilken begivenheden er opstået eller brugernummer i tilfælde af til, fra og Frakoblingsrapport hændelser. Eksempel 1: Meddelelsen er : Dette betyder, at en alarm er opstået i zone nr. 3. Eksempel 2: Meddelelsen er : Dette betyder, at systemet er blevet lukket (tilkoblet) af bruger nr Udføre gangtest Gangtest er en absolut nødvendighed for at undersøge om alle detektorer fungerer korrekt uden at forstyrre naboerne med en høj sirene. Testen bør udføres mindst en gang om ugen, og skal omfatte alle detektorer i alle zoner. Bemærk: Under testperioden vil 24-timers zoner ikke aktivere en alarm, hvis de forstyrres, mens brandzonen vil fungere normalt. En typisk test vil foregå således: A. Tryk på testknappen ( ). B. Displayet vil anmode om indtastning af brugerkode: INDTAST KODE C. Indtast din kode. Sirenen vil lyde i 2 sekunder og displayet viser: TESTER D. Gå rundt i det beskyttede område og sørg for at udløse hver eneste af detektorerne (gå på tværs af 7. BRUGEROPSÆTNING 7.1 Hvilke opsætninger har du behov for? Montøren leverer et system klar-til-brug så godt som tilpasset dine ønsker og behov. Der er dog nogle få indstillinger, som mangler. Bemærk: Selvom brugeropsætningen er dit ansvar, kan du anmode montøren om at udføre den for dig (undtagen følg-mig telefonnummeret, som skal omprogrammeres for at følge dig, samt brugerkoderne som du ønsker at hemmeligholde). Brugeropsætningen inkluderer: Isolering af zoner Afgør hvilke zoner som isoleres (afbrydes) under den aktuelle frakoblingsperiode samt den næste tilkoblingsperiode. Gennemse isoleringslisten Vis isolering angiver nummer og navn på de isolerede zoner, en efter en. Genkald seneste isoleringsliste genkald isolering genanvender den foregående isoleringsliste, som automatisk bliver suspenderet efter frakobling men dog stadig gemt i PowerMax s hukommelse. detektorernes synsfelt og åben/luk døre og vinduer). Hver gang en detektor detekterer: Succesmelodien vil lyde, Zonenavn og -nummer vil blive vist i displayet et kort øjeblik, Zonenavn og -status vil blive meddelt i højttaleren EKSEMPEL 1: Du udløser alarm i dagligstuen (zone 11). Displayet viser: STUE Z11 ALARM Efter 5 sekunder vil displayet vende tilbage til: TESTER EKSEMPEL 2: Du åbner et vindue i gæsteværelset (zone 14). Displayet viser: GÆSTEVÆRELSE Z14 ÅBEN Efter 5 sekunder vil displayet vende tilbage til: TESTER E. Når dette er gjort, tryk gentagne gange på tasten. Displayet vil vise testresultatet, zone for zone, i stigende zonenummerorden, f.eks.: GÆSTEVÆRELSE (skiftende mellem) Z14 eller: Z14 IKKE hvis ikke der er modtaget signal fra Z13. F. For at gentage testen, tast. For at afslutte testsekvensen, tast. Displayet viser: <> FOR AFSLUT G. Tast. Displayet vender tilbage til normal status. Programmering af følg-mig (4.) telefonnummer* Indtast det telefonnummer, hvor du kan kontaktes under dit fravær. PowerMax foretager herefter opkald til dette nummer. Opsætning af brugerkoder* Programmering af sikkerhedskoder til dig og 7 andre brugere af systemet. Kode 5 til 8 er brugerkoder for Frakoblingsrapport(se afsnit 2.9 for nærmere detaljer). Indlæsning af håndsendere og trådløse tastaturer* - Registrering i PowerMax+, ID koderne for hver håndsender og tastatur (multi-funktions CodeSecure typer), således at PowerMax+ kan reagere på kommandoer sendt fra disse. Opsætning af tale funktioner* - Valg eller fravalg af tale meddelelser. Automatisk tilkobling* - Valg eller fravalg af automatisk tilkobling (på et forud angivet tidspunkt). Opsæt tilkoblings tidspunkt Angivelse af tidspunktet for automatisk tilkobling. Anvendelse af squawk* - Valg/fravalg af LAV/MID/HØJ squawk (kort sirene lyd) ved tilkobling og frakobling. Alle mulighederne er for trådløs sirene. For kablet sirene vil LAV, MID og HØJ optionerne betragtes som "squawk TIL". 16 DD5467U
65 Indstilling af ur * justering af det indbyggede ur. Indstilling af dato* justering af indbygget kalender. Opsætning af tidsskema* - Opsætning af tidsskemaer for start/stop aktivering af enheder. * De stjernemarkerede punkter kan der alene opnås adgang til via superbrugerkoden. 7.2 Brugeropsætningsmenu Figur 7 viser hvordan man kommer ind i brugeropsætningsmenu. Visning i frakoblet stand, når alle zoner er lukkede (00:00 eller andre tal, der viser den aktuelle tid) Instruktion: tast <> tast Displayet viser Instruktion: Indtast 4-cifret Master bruger kode (default 1111) eller Bruger kode (se note nedenfor). Disse menuer vises kun hvis Isolering er blevet slået TIL af montøren. * Menuer der er markerede med en asterisk, kan kun åbnes hvis Master bruger kode er indtastet. * MONTØR MENU vises kun hvis der i BRUGER TILLADELSE er valgt AKTIVERET af montøren (*) (*) KLAR 00:00 NORMAL MENU BRUGER MENU MONTØR MENU [Master/bruger kode] OPSÆT ISOLERING (*) INDLÆS HÅNDSEND. (*) SÆT TALE MENU (*) AUTOM. TILKOBL. (*) AUTOM. TILK. TID (*) SQUAWK MENU (*) SÆT TID&FORMAT (*) SÆT DATO&FORMAT (*) VIS ISOLERING GENKALD ISOLER. INDT. TLF.NUMMER OPSÆT BRUGERKOD. TIDSSKEMA (*) (**) MONTØR MENU <> FOR AFSLUT Figur 7 Indgang til brugeropsætningsmenu Afsnittene inkluderer instruktioner til bruger opsætning, trin for trin. Figur 8 giver et overblik over hele brugeropsætningsmenuen. Dette skema kan også bruges som den eneste vejledning i hele opsætningsprocessen, i stedet for at gennemgå instruktionerne trin for trin. 7.3 Isolering af Zoner A. Generel orientering Du kan programmere PowerMax til at isolere udvalgte zoner uanset om disse zoner er i funktion (uforstyrrede) eller åbne (forstyrrede). Isolering giver mulighed for fri bevægelighed indenfor angivne zoner selv om alarmcentralen er tilkoblet. Det anvendes desuden til midlertidig at afbryde en zone som er fejlbehæftet og derfor skal repareres. Brandzoner kan ikke isoleres. HUSK Isolering sker på bekostning af sikkerheden! Isolering af zoner skal udføres mens systemet er frakoblet. Bemærk: Isolering af zoner sker alene for en frakoblings-/ tilkoblingsperiode. Frakobling af systemet efter tilkobling afbryder hele isoleringslisten, som dog kan genkaldes og genanvendes senere. B. Isoleringsprocedure Når du har indtastet korrekt brugerkode (se afsnit 7) vil displayet vise: OPSÆT ISOLERING Hvis du nu taster <VIS/>, vil nummer, status og navn på den første zone automatisk blive angivet. Der er 3 forskellige muligheder: Åben: Zonen er ikke afsikret du kan isolere zonen, hvis du ikke ønsker, eller ikke ved hvordan problemet skal løses endnu. Isoleret: Zonen er aktuelt isoleret (du har isoleret zonen tidligere, men har endnu ikke tilkoblet systemet) Funktion: Hvis alle zoner er i fuld funktion vil status blive angivet som Funktion. Hvis f. eks. zone 9 er åben og du ønsker at isolere den, og alle øvrige zoner er i fuld funktion: (hvis du ønsker at checke næste zones status) Z09 Å BEN (skiftende mellem) KØKKEN <> FOR ISOL. Z09 Å BEN (skiftende mellem) KØKKEN Z01 FUNKTION (skiftende mellem) FORDØR INDTAST ISOL. Du kan nu vælge et hvilket som helst punkt i brugeropsætningsmenuen eller afslutte programmeringen ved at taste <AWAY>. Når displayet viser <> FOR AFSLUT, tast da <>. Efter afslutning af isoleringsfunktionen, vil ISOL. Blinke i displayet så længe systemet er frakoblet, og vil forsvinde når systemet er tilkoblet: KLAR ISOL. Ell. IKKE KLAR ISOL. Bemærk: Isolering vil skiftevis blinke i displayet sammen med andre meddelelser som eks. Kan være: problem, hukommelse og meddelelse. C. "Ikke-isolerings procedure Hvis du ønsker at aktivere en zone igen efter afslutning af isoleringslisten. Gå da blot ind i indtast isolering menuen (se afsnit 7.3B), og tast <> eller <BACK> indtil den zone, som du ønsker at ikke-isolere vises i displayet. Her er et eksempel: Z11 ISOLERET STUE (skiftende mellem) <OFF>FOR SLET Z11 FUNKTION STUE (skiftende mellem) DD5467U 17
66 Du kan nu taste <HOME> og derefter vælge et af de øvrige punkter i brugeropsætningsmenuen, eller taste <AWAY> for at afslutte programmeringen. Når displayet viser <> FOR AFSLUT, tast da <> Se listen over isolerede zoner Når du har indtastet korrekt brugerkode vil displayet vise: OPSÆT ISOLERING Tast <> - displayet viser så: VIS ISOLERING Tast <VIS/> - displayet viser så: ISOLERINGSLISTE Hvis du nu taster <VIS/> - vil nummer, status og navn på den første af de isolerede zoner blive angivet. Du kan nu taste <> gentagne gange for at gennemse alle de isolerede zoner i stigende nummerorden. Når dette er gjort, tast <HOME> og du er tilbage i VIS ISOLERING, tast <AWAY> og du vil være tilbage i <> FOR AFSLUT. 7.5 Genkald den sidste isoleringsliste Tilkobling af systemet med en eller flere zoner isoleret er reelt en partiel tilkobling. En identisk partiel tilkobling kan gentages ved at genkalde den seneste isoleringsliste (som blev suspenderet og gemt ved frakobling af systemet). Når korrekt brugerkode er indtastet (se afsnit 7.2) vises følgende i displayet: OPSÆT ISOLERING Tast <> 2 gange - displayet viser så: GENKALD ISOLER. Fortsæt herefter således: <>F/GENKALD GENKALD ISOLER. Du kan nu vælge et hvilket som helst af de øvrige punkter i brugeropsætningsmenuen, eller afslutte programmeringen ved at taste <AWAY>. Når <> FOR AFSLUT vises, tast da <>. 7.6 Programmering af 4 telefonnumre Her indtastes op til 4 telefonnumre til hvilke systemet skal rapportere de hændelser, der blev definerede af montøren der installerede PowerMax+. Montøren kan også indtaste disse telefonnumre, hvis det ønskes. Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), vil displayet vise: INDTAST TLF.NR. Du kan nu programmere de fire numre således: 1.PRIV.TLF.NR. XXXXXXXXX [Tlf.nr.] XXXXXXXXX XXXXXXXXX 1.PRIV.TLF.NR. 2.PRIV.TLF.NR. Fortsæt på samme måde op til det 4. telefonnummer Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <>. 7.7 Programmering af brugerkoder Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), tast <> indtil displayet viser: INDTAST KODE Bemærk: Brugerkode 1 ændrer den fabriksindstillede superbrugerkode som er tildelt superbrugeren af systemet. Denne kode kan ikke slettes. Brugerkode 2, 3 og 4 kan tildeles øvrige brugere familiemedlemmer, medarbejdere etc. Kode 5 til 8 tildeles Frakoblingsrapport brugere (se afsnit 2.9 for oplysninger om frakoblingsrapport mode). ADVARSEL! Kode 0000 er ikke gyldig og kan derfor ikke anvendes. Bemærk: Overfaldskoden 2580 kan ikke vælges som en normal brugerkode. Ethvert forsøg herpå vil blive afvist af PowerMax. Programmering af koderne foretages således: [4-cifret kode] (f.eks. 6584) KODE 1 KODE 1: KODE 1: 6854 KODE 1: 6854 KODE 2 Fortsæt på samme måde op til kode 8. KODE 8: 5537 INDTAST KODE Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <>. 18 DD5467U
67 (5) (Første display er KLAR eller IKKE KLAR) KLAR 00:00 (For at se status på næste zone) (5) (Eksempel) OPSÆT ISOLERING Z01: ÅBEN <> FOR ISOLER Skiftende (5) (5) (1) INDT. TLF.NUMMER NORMAL MENU BRUGEROPSÆTN. <> FOR GENKALD (3) INDTAST KODE [4-cifret master/bruger kode] NOTER (1) Mørke menuer er kun tilgængelige hvis Master kode er indtastet (2) For årstallet indtast kun de sidste to cifre. (3) Tast for at vise nummer, status og navn på første Isolerede zone. Tast flere gange for at se alle Isolerede zoner.s. (4) For at indsætte A (AM) tast (eller en af de tre taster ovenover). For at indsætte P (PM) tast (eller en af de tre taster ovenover). (5) OPSÆT/VIS/GENKALD ISOLERING menuerne er kun tilgængelige hvis Manuel Isolering er valgt. (montør opsætning). (6) Hvis der i SÆT TALE MENU en er valgt TALE TIL, vil AFBRYD HØJTTALER tasten på tastaturet være aktiv. INSTALLER MENU Z01: ISOLERET Skiftende (1) OPSÆT BRUGERKOD. bruger kode 1 bruger kode [kode] bruger kode 1 (eksempel) (til næste bruger kode 2,3...8) Til næste (op) eller foregående (ned) håndsender indlæsning (1) INDLÆS HÅNDSEND. håndsend nr: send nu håndsend nr: 1 Indtast håndsender nr. hvis dette ikke (tryk på en vilkårlig tast) ønskes (1)(6) SÆT TALE MENU tale til tale fra tale fra (Hvis det er det aktuelle valg) hvis dette ikke ønskes (1) AUTOM. TILKOBL. AUT. TILK. FRA AUT. TILK. TIL enable autoarm (Hvis det er det aktuelle valg) (1) (1) (1) AUTOM. TILK. TID tilk. tid : A [Tid] (se format og eksempel I SÆT TID&FORMAT nedenfor) SQUAWK MENU hvis dette ikke SÆT TID&FORMAT US FORMAT - 12H ønskes EU FORMAT - 24H Tid : A [Tid] e.g. 07:55P (4) Tid : [Tid] e.g. 19:55 hvis dette ikke (1) SÆT DATO&FORMAT dato DD/MM/YYYY ønskes dato MM/DD/YYYY (1) (1) VIS ISOLERING TIDSSKEMA (se figur 8A næste side) MONTØR MENU GENKALD ISOLER. <> FOR AFSLUT (Se figur 8) dato: / / dato: / / (dato)(2) (e.g. 30/12/2000) (dato)(2) (e.g. 12/30/2000) NEXT 1. priv. tlf.nr.# 2. priv. tlf.nr.# 3. priv. tlf.nr.# 4. priv. tlf.nr.# Tlf.nr. Tlf.nr. Tlf.nr. Tlf.nr. Tid 07:55 P Tid 19:55 dato 30/12/2000 dato 12/30/2000 KØKKEN ISOLERINGSLISTE Adgang til MONTØR MENU (beskrevet i installations og programmerings Guide) Figur 8 Skema over brugeropsætningsmenu KØKKEN squawk fra sqwk vol. lav sqwk vol. mid sqwk vol. høj For at manøvrere i menuerne, bruges for det meste nedenstående taster: Et trin tilbage Et niveau op i menuen Tilbage til <> for afslut (For at se valgmulighederne, brug og BACK tasterne.) Et trin frem VIS / Vis/bekræft data SÆT TID&FORMAT TIDSSKEMA SÆT DATO&FORMAT Sort firkant visesfor ENHED NR. X-10 enhed Enhedens nummer (2 cifre) Hvis du indtaster 00 og trykker, vil PGM blive vist SØNDAG MANDAG TIRSDAG ONSDAG TORSDAG FREDAG LØRDAG DAGLIG OPERATION NR. 1 OPERATION NR. 2 OPERATION NR. 3 start - HH:MM stop - HH:MM or BACK Noter 1. Indtast tid med 10 minutters opløsning. TID - - / For at slette en vist tid, tryk OFF. (Indtast start/stop tid) Figur 8A Tidsskema Funktion OPERATION NR. 4 For at manøvrere i menuerne, bruges for det meste nedenstående taster: Et trin frem VIS / Vis/bekræft data Et trin tilbage Et niveau op i menuen Tilbage til <> for afslut DD5467U 19
68 7.8 Indlæsning af håndsendere og trådløse tastaturer Håndsendere og tastaturer er multi-funktions trådløse enheder af CodeSecure typen. Op til otte personer/ systembrugere kan med håndsendere og/eller trådløse tastaturer opnå bedre, hurtigere og mere sikker kontrol af systemet. PowerMax+ skal kunne genkende den unikke ID kode for hver af disse enheder for at kunne reagere på kommandoer der sendes med dem. For indlæsning af trådløse tastaturer, henvises til den medfølgende brugermanual. Indlæsning af håndsendere er beskrevet nedenfor. Indsaml alle håndsendere, som du ønsker at tilknytte systemet, før du foretager dig yderligere og sørg for at de alle har monteret batterier. Indlæsning af håndsendere foretages således: A. Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), Tast <> (flere gange hvis nødvendigt) indtil Displayet viser INDLÆS HÅNDSEND. B. Tast <>. Displayet viser HÅNDSEND.NR.: C. Hvis håndsenderen, som du er ved at indlæse, skal defineres som håndsender nr. 5. Under forudsætning af, at hukommelsesplads nr. 5 er fri der har endnu ikke været indlæst nogen håndsender på denne placering tryk på <5> tasten. Displayet vil skifte til: HÅNDSEND.NR.: 5 Den ledige plads til højre i displayet indikerer, at hukommelsespladsen er fri. D. Tast <>. Displayet vil anmode dig om at foretage en transmission fra den valgte håndsender: SEND NU E. Aktiver valgte håndsender ved at taste på en af dets knapper. Som reaktion herpå vil succesmelodien (- - - ) lyde, og displayet vil skifte til: HÅNDSEND. NR.5 En mørk boks dukker op i højre side, som indikation af, at den valgte håndsender er blevet indlæst som håndsender nr. 5. Bemærk: Hvis samme håndsender allerede er indlæst et andet sted, vil succesmelodien lyde 2 gange efter hinanden. F. Fra dette punkt, kan du fortsætte i flere forskellige retninger: Hvis du ønsker at indlæse andre håndsendere, vælg det ønskede nr. ved at: - Taste <> for at gå op (678...) - Taste <BACK> for at gå ned (432...) - Taste <HOME> <HÅNDSENDERNR.>. For at vende tilbage til hovedmenuen, tast <AWAY>. Dette bringer dig tilbage til følgende skærmbillede: <> FOR AFSLUT Du kan nu gense og vælge et af de andre punkter i menuen (ved at taste <> eller <BACK>). 7.9 Sletning af håndsendere og trådløse tastaturer Hvis en håndsender eller et trådløst tastaturs hukommelsesplacering er optaget skal det slettes før nye ID kan indlæses. For at slette et eksisterende ID, fortsæt således: A. Vælg den ønskede håndsender som beskrevet i det _ foregående afsnit 7.8, trin A-C. Hvis f.eks. Håndsender Nr. 5 vælges, vil displayet vise: HÅNDSEND. NR.5 B. Tast <>. Displayet skifter til: <OFF> for slet C. Tast <OFF>. Displayet skifter til: HÅNDSEND. NR.5 Bemærk, at den mørke boks i højre side er forsvundet. Det er herefter muligt, at indlæse et nyt ID. Det er også muligt, at lade pladsen være ubenyttet, og derefter gå til hovedmenuen Indstilling af talemuligheder Husk: Talemeddelelser afspilles af den indbyggede højttaler, såfremt: - Stemmefunktionen er aktiv som vist nedenfor - Højttaleren er aktiveret ved at trykke 7 tasten (afsnit 3.3). Følgende giver mulighed for at vælge en af 2 mulige funktioner: TALE TIL: Tale meddelelser TALE FRA: Ingen tale meddelelser Den aktuelt valgte mulighed vil blive markeret med en mørk valgboks ( ) i højre side af displayet. Du kan se de øvrige muligheder (som ikke er markeret med en mørk boks i højre side), ved at taste <>. En mørk boks vil dukke op, hvis du taster <>, mens en af de øvrige muligheder vises. For at indstille talefunktionen fortsæt således: Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), tast <> indtil displayet viser: INDSTIL TALE Herefter fortsættes som følger: Ønskes dette ikke: TALE FRA Hvis dette ønskes: TALE TIL (hvis det er den aktuelle indstilling) TALE FRA INDSTIL TALE Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <>. Bemærk: Når håndsender Model MCT-234 anvendes med PowerMax+, skal der vælges TALE TIL Automatisk tilkobling PowerMax+ kan indstilles til automatisk at tilkoble alarmen på et hvilket som helst tidspunkt. Efter indtastning af gyldig superbrugerkode, tast da <> indtil displayet viser AUTOM. TILKOBL, herfra fortsættes som følger: AUT.TILK.TIL (hvis det er den aktuelle indstilling) Ønskes dette ikke: AUT.TILK.FRA 20 DD5467U
69 AUT.TILK.FRA AUTOM. TILKOBL. Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <> Sæt Automatisk tilk. Tid. Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), Tast <> (flere gange hvis nødvendigt) indtil Displayet viser: AUTOM. TILK. TID Herfra fortsættes som følger: [tid cifre] (f.eks. 12:55 A) TILK.TID : A TILK.TID 12:55A A. Hvis12h format ønskes, fortsæt som følger: [Klokkeslæt] (f. eks. 12:55 A) US FORMAT - 12H TID TID : A 12:55 A TID HH:MM A Bemærk: For at vælge A (AM = Formiddag kl til 11.59) tast [] og for at vælge P (PM = Eftermiddag kl til 23.59) tast [#]. B. Hvis 24h format ønskes, fortsæt som følger: US FORMAT - 12H EU FORMAT - 24H TILK.TID 12:55A TID : AUTOM.TILK.TID Bemærk: 1. For 12h/24h time format henvises til afsnit Tast "" for A (AM), eller tast "#" for P (PM) Squawk Menu Det kan vælges om PowerMax+ skal aktivere (eller ikke aktivere) høj/mid/lav sirene lyd, et kort øjeblik, ved tilkobling (1 bip) og frakobling (2 bip). Sker kun ved anvendelse af håndsender. Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), tast <> indtil displayet viser: SQUAWK MENU Herefter fortsættes som følger: SQUAWK FRA (hvis det er den aktuelle indstilling) Ønskes dette ikke: SQUAWK VOL.LAV [Klokkeslæt] (f. eks. 19:55) TID 19:55 TID 19:55 TID HH:MM Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <> Indstilling af Dato og Format Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), tast <> indtil displayet viser: SET DATO&FORMAT. Herfra fortsættes som følger: DATO MM/DD/YYYY Ønskes dette ikke: DATO DD/MM/YYYY Ønskes dette ikke: SQUAWK VOL.MID Ønskes dette ikke: SQUAWK VOL.HØJ Ønskes dette: SQUAWK VOL.HØJ [Dato] f.eks. 01/01/2004 DATO --/--/---- DATO 01/01/2004 DATO 01/01/2004 For kablet sirene vil LAV, MID og HØJ optionerne betragtes som "squawk TIL". Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <> Indstilling af tid og format Efter indtastning af gyldig superbrugerkode (se afsnit 7.2), tast <> indtil displayet viser: SÆT TID&FORMAT DATO DD/MM/YYYY Du kan herefter skifte til et af de øvrige menupunkter i Brugeropsætningsmenuen, eller afbryde programmeringen ved at taste <> indtil <> FOR AFSLUT vises i displayet tast derefter <> Tidsskema Funktion Tidsskemaet giver mulighed for at starte og stoppe bestemte elektriske enheder op til fire gange i døgnet. Du kan vælge dagen (søndag, mandag, tirsdag, onsdag, torsdag, fredag, lørdag, eller daglig) og derefter vælge tidspunkt for henholdsvis start og stop af den valgte enhed. Forløbet af tidsskemaopsætning er vist i figur 8A. DD5467U 21
70 8. AFLÆS HÆNDELSESLOG 8.1 Beskrivelse af hændelseslog Alle hændelser gemmes i en hændelseslog som indeholder op til 100 hændelser. I Loggen har du mulighed for at gennemgå hændelserneen efter en og herved kontrollere systemets funktioner. Hvis loggen bliver fyldt op (antallet af registrerede hændelser når 100) fortsætter systemet med at acceptere nye hændelser på bekostning af de ældste hændelser, som slettes efterhånden som der registreres nye hændelser. Dato og tidspunkt for hændelsens opståen gemmes for hver enkelt hændelse. Når loggen gennemlæses, bliver hændelserne vist i kronologisk rækkefølge fra de seneste til de ældste. Idet INDTAST KODE: (Indtast 4-cifret Master bruger kode) HÆNDELSESLOG Sidste hændelse Hændelsen før sidste Ældste hændelse 8.2 Aflæsningsprocedure For at gennemse hændelsesloggen, fortsæt således: A. Når systemet er i normal funktion, tast da stjernetasten (). Displayet skifter til: INDTAST KODE B. Indtast superbrugerkode. Hvis koden er korrekt, lyder succesmelodien og displayet angiver: JOURNAL/LOG Vigtigt! Indtastning af forkert kode 5 gang i træk, vil blokere tastaturet efterfølgende i 30-sekunder. C. Tast <>. Den seneste hændelse vil blive angivet. Hvis den seneste alarm f.eks. var i zone 13 vil displayet angive: Z13 ALARM 9. VEDLIGEHOLD der er begrænset plads i displayet, angives beskrivelsen af hændelsen først og derefter dato og tidspunkt. De 2 skærme vises skiftevis gentagne gange, indtil du taster <> for at gå videre til den næste i rækken (en ældre hændelse), eller indtil du ikke har trykket på en tast i 4 minutter, hvorefter systemet automatisk vender tilbage til normal funktion. Adgang til hændelsesloggen opnås ved at taste stjernetasten () og derefter superbrugerkoden. Der henvises til figur 9 for at få overblik over anvendelsen af loggen. Skemaet kan fungere som den eneste vejledning i anvendelsen af hændelsesloggen, i stedet for at gennemgå den beskrevne trinvise procedure. SLET HÆNDELSER Bemærk: Systemet vil ikke tillade dig at slette hændelsesloggen. Kun montøren er bemyndiget til at udføre denne handling. Figur 9. Anvendelse af hændelseslog Og derefter: 09/02/04 15:37 < FOR AFSLUT (Tilbage til Normal menu) De to display vil blive angivet skiftevis indtil du taster <> igen for at skifte til næste hændelse, eller indtil systemet automatisk vender tilbage til normal funktion efter 4 minutter. D. Tast <> så ofte, som det er nødvendigt, indtil du har aflæst alle de data som du ønsker. For at afslutte hændelsesloggen: Tast <HOME> eller <AWAY> fra et hvilket som helst sted inde i loggen. Displayet viser: <> FOR AFSLUT - Tast <>. Systemet vil vende tilbage til normal funktion. 9.1 Udskiftning af Backup Batteri Powermax+ forsynes via det normale ledningsnet i det beskyttede område, men indeholder tillige et internt 7,2V ell. 9,6V batteri som opretholder strømforsyningen under strømsvigt. Det er derfor ekstremt vigtigt at opretholde batteriets tilstand, og navnlig hurtig udskiftning ved modtagelse af problemmeddelelser (fulgt op af en lysende Problem LED indikator): CPU SVAGT BAT. Udskiftning af batteriet er forholdsvis simpel så du behøver ikke at kontakte montøren for at gøre det: 1 Åben låge 2 Skru skruen ud og aftag dæksel 3 Monter en genopladelig batteripakke ( se mærkat på batteri dæksel) til batteri stikket. Påsæt dæksel, skrue og luk lågen. Figur 10. Udskiftning af batteri * BEMÆRK! Hvis lågen fjernes vil sabotagealarmen aktiveres problemindikatoren vil lyse og både hukommelse og problem vil blinke i displayet. Hvis systemets status undersøges nu ved at taste <>, vil CENTRL SAB. ALRM og CENTRL SAB. ÅBEN og CENTRL SVAGT BAT. Vises i displayet. Sæt batteriholderen tilbage og sæt atter batterilågen fast med skruen. Når de friske batterier er indsat og lågen er fastgjort, vil PROBLEM indikatoren slukke. HUKOMMELSE. meddelelsen vil nu blinke i displayet (på grund af den sabotagealarm du udløste). Denne slettes ved at tilkoble systemet og frakoble igen så snart udgangsforsinkelsen påbegyndes. 9.2 Udskiftning af batterier i trådløse enheder 22 DD5467U
71 Trådløse detektorer tilsluttet systemet forsynes via et Højkapacitets Litium batteri, som har en levetid på adskillige år afhængig af antallet af detekteringer og transmissioner til alarmcentralen. Hvis et batteri bliver svagt, vil detektoren selv afgive et svagt batteri signal til alarmcentralen, som vil vise en meddelelse om svagt batteri i displayet sammen med zoneinformationerne (se afsnit 5.2). Håndsendere som anvendes til at betjene systemet forsynes af et 12V Alkaline batteri (type A27), hvis levetid er ca. et år, hvis du ikke trykker på knappen mere end 10 gange pr. dag. Svagt batteri angives ved, at den røde indikator på håndsenderen blinker (i stedet for at lyse), når du holder knappen nede. Når en svagt batteri indikation dukker op for første gang, skal det forstås som et forvarsel. Den giver dig normalt god tid (ca. 30 dage) til at købe et nyt batteri og udskifte batteriet, og håndsenderen vil være fuldt funktionsdygtigt i hele denne periode. Det anbefales dog, at batteriet udskiftes så hurtigt som muligt. Anvend det batteri, som anbefales i detektorens egen monteringsvejledning. Hvis ikke du har vejledningen, spørg din montør til råds eller anmod ham om at foretage udskiftningen. Det Trådløse Tastatur forsynes af et 3V Litium batteri med lang levetid. Hvis batteriet er svagt vil dette angives i hændelsesloggen som, "T01 Svagt Batteri" (Indikering af 10. SYSTEMBEGRÆNSNINGER Uanset, at alarmsystemet er højst pålideligt, vil det være forkert at sige, at systemet yder den perfekte og ultimative beskyttelse mod indbrud, glasbrud og brand. Selv de mest avancerede alarmsystemer kan "overvindes" eller kan til tider fejlagtigt undlade at afgive alarm. Nogle af grundene hertil nævnes derfor i det efterfølgende: Sløset vedligeholdelse: Hvis systemet bruges over en lang periode uden at foretage de foreskrevne test af systemet, er der risiko for, at nogle vigtige enheder svigter, f.eks. kan der opstå fejl i detektorer og sirener uden synlige tegn herpå. Hvis et varsel om svagt/dødt batteri ignoreres, kan det betyde, at der ikke vil være strømbackup i tilfælde af strømsvigt på ledningsnettet. Strømsvigt: I tilfælde af langvarige strømsvigt (uden at backupbatteriet checkes) kan backupbatteriet løbe tør for strøm, og det beskyttede område står således ubeskyttet hen. APPENDIKS A. ORDBOG Alle fagudtryk anført i kursiv inde i forklaringsteksten kan slås op særskilt. Afbrydningsperiode: Når en alarm aktiveres, vil den indbyggede sirene først lyde i en begrænset periode, afbrydningsperioden, indstillet af montøren. Hvis du aktiverer alarmen ved en fejl, kan du frakoble systemet inden udløbet af afbrydningsperioden, altså inden den eksterne sirene lyder, og før alarmen rapporteres til de eksterne rapportmodtagere. Alarm: Der er 2 alarmtyper: Sirenealarm Såvel den interne som den eksterne sirene lyder og alarmcentralen afgiver hændelsesrapport via telefonen. Tavs alarm Sirenen forbliver tavs, men alarmcentralen afgiver hændelsesrapport via telefonen. Alarmen kan aktiveres af: Detektering af bevægelse af en detektor Ændring af magnetkontaktens status et lukket vindue eller en dør bliver åbnet. Detektering af røg af en røgdetektor Sabotage på en af detektorerne De 2 nødkaldstaster holdes nede samtidig (panik) svagt batteri i Trådløst Tastatur nr. 01), og meddelelsen Trådløst Tastatur vil høres. For udskiftning af batteri i det trådløse tastatur, se MCM- 140 Trådløst Tastatur Bruger guide. Efter udskiftning af batteriet, vil detektoren sende et batteri signal til alarmcentralen og svagt batteri meddelelsen bliver slettet. 9.3 Periodisk Test De enkelte enheder i dit sikkerhedssystem er udviklet til at være så vedligeholdelsesfrie som overhovedet muligt. Alligevel bør du foretage en gangtest mindst en gang om ugen og efter evt. alarm hændelser for at sikre dig, at systemet fungerer korrekt. Gør som beskrevet i afsnit 6.5. Hvis der opstår problemer, skal du straks kontakte montøren. 9.4 Rengøring af Alarmcentralen Alarmcentralen skal af og til rengøres, hvis den berøres med snavsede fingre og støves af efter længere tids brug. Tør kabinettet af med en blød klud, som er fugtet let med en blanding af vand og mild vaskemiddel, derefter aftørres med en tør klud. Anvend aldrig skurepulver eller produkter indeholdende petroleum, acetone eller fortynder. Dette vil skade kabinettet og gennemsigtigheden af vinduet i toppen af enheden. Problemer med telefonlinien: Telefonlinien kan blive frakoblet, kortsluttet o.l.. Systemet vil således ikke være i stand til at rapportere alarmbegivenheder til Kontrolcentralen. Sirenen er ikke altid i stand til at vække sovende personer: Sirene eller klokker, som er monteret ude eller langt fra soveværelset, er ikke altid i stand til at vække personer, som sover bag lukkede døre eller i tilstødende bygninger. Systemet bliver sommetider "narret": Indtrængende personer, som har tilstrækkelig teknisk viden, kan til tider finde måder, hvorpå systemet kan narres eller forbipasseres, uden at detektorerne afgiver alarm. Røgdetektorers begrænsninger: I mange tilfælde afgiver røgdetektorer ikke alarm, fordi branden er opstået på en anden etage eller for langt væk fra detektoren. Ovennævnte problemer er det tydelige bevis på, at uanset hvor godt alarmsystemet er, kan det under ingen omstændigheder erstatte person- og tings-forsikringer. Alarmcentral: Alarmcentralen er et kabinet, som indeholder de elektriske kredsløb og mikroprocessorer som kontrollerer alarmcentralen. Den indsamler oplysninger fra de forskellige detektorer, behandler disse og reagerer herpå på forskellige måder. Det indeholder endvidere brugerfladen kontroltaster, numeriske taster, display/skærm, buzzer og højttaler. Brugerkode: PowerMax+ er udviklet til at adlyde dine kommandoer under forudsætning af, at du er udstyret med en gyldig sikkerhedskode. Uautoriserede personer kender ikke koden, så ethvert forsøg på at frakoble eller ødelægge systemet vil ske forgæves. Nogle funktioner kan udføres uden brugerkode, idet de ikke forringer sikkerhedsniveauet i systemet. Dørklokkezoner: Giver dig mulighed for at følge aktivitet i det sikrede område, mens alarmsystemet er frakoblet. Hver gang en dørklokkezone åbnes, vil højttaleren i centralen give en DING-DONG lyd fra sig. Lyden gentages ikke, når zonen atter lukkes (vender tilbage til normal status). Parcelhusejere kan anvende denne funktion til at meddele, at der er gæster eller til at se efter børn. Virksomheder kan DD5467U 23
72 anvende funktionen til at meddele, at der er kunder i forretningen, eller når personale går ind i forbudt område. Bemærk: Montøren vil aldrig definere en 24 timers zone eller en brandzone som en dørklokkezone, idet begge zonetyper aktiverer en alarm, hvis de forstyrres, selv om systemet er frakoblet. Selv om en eller flere zoner er defineret som dørklokke- zoner, kan du stadig tilkoble og frakoble dørklokke- funktionen. Detektor, trådløs: En passiv infrarød detektor, der er kombineret med en trådløs PowerCode sender i samme enhed. Ved detektering af bevægelse, vil detektoren sende en unik identifikationskode sammen med en alarmrapport og forskellige andre statusrapporter til alarmcentralen. Efter afsendelsen, vil detektoren stadig reagere på yderligere bevægelser, men oftest først efter en periode på nogle minutter uden bevægelse. Eksterne rapportmodtagere: En rapportmodtager kan enten være en professionel udbyder af sikringsydelser (Kontrolcentral) eller et familiemedlem eller ven, som er indstillet på at se efter det sikrede område under dit fravær. Alarmcentralen rapporterer begivenheden via telefonnettet i begge tilfælde. Åben zone: En zone i alarm (dette kan være forårsaget af et åbent vindue eller dør, eller ved detektering af bevægelse i en detektors synsfelt ). En forstyrret zone anses som ikke sikret. Frakobling: Det modsatte af tilkobling en handling, som får alarmcentralen til at vende tilbage til normal status. I denne status vil kun brandzoner, panikalarm og 24-timers zoner afgive alarm. Fuld tilkobling (AWAY): Denne tilkoblingstype anvendes, hvis hele det sikrede område skal beskyttes. Alle zoner, indvendige zoner og perimeter zoner, beskyttes på samme måde. Frakoblingsrapport: Hvis systemet Tilkobles med denne mulighed, vil en Frakoblingsrapport blive sendt til specifikke telefoner når kode/håndsender holdere 5-8 frakobler centralen. Denne mulighed er anvendelig til bl.a. forældre der ønsker at blive informeret om at deres børn er kommet hjem fra skole. Der kan i PowerMax+ indtales et navn for hver håndsenderholder 5-8. Hurtig tilkobling: Tilkobling af alarmcentralen uden brug af brugerkode. Alarmcentralen anmoder ikke brugeren om en kode, når du trykker på tilkoblingstasten. Montøren skal under programmering af systemet tillade eller nægte denne tilkoblingsform. Ikke-alarm zone: Montøren kan definere en zone til at have en anden rolle end at afgive alarm. F.eks. kan en detektor monteres på et sted, hvor belysningen er dårlig, og anvendes til automatisk at tænde lyset, når der går personer ind i detektorens synsfelt. Et andet eksempel er en trådløs håndsender tilknyttet en zone, som kontrollerer åbningsmekanismen i en garageport eller lignende. Magnetkontakt, trådløs: En magnetkontakt og en PowerCode sender er kombineret i samme enhed. Magnetkontakten monteres på døre og vinduer, for at detektere ændringer af døren/vinduets status (fra lukket til åben og omvendt). Ved detektering af åbning af døren/vinduet vil magnetkontakten sende en unik identifikationskode sammen med en alarmrapport og forskellige andre statusrapporter til alarmcentralen. Alarmcentralen vil, hvis den ikke er tilkoblet på dette tidspunkt, betragte alarmsystemet som ikke klar til tilkobling indtil den modtager et signal fra samme detektor om, at den er vendt tilbage til normal status. Nat tilkobling (HOME) Denne type tilkobling anvendes, hvor der stadig er personer inde i det sikrede område. Et klassisk eksempel er om natten, hvor familien er ved at gå i seng. Med NAT TILKOBLING vil perimeterzoner være sikrede i modsætning til indvendige zoner. Konsekvensen heraf er, at bevægelse i indvendige zoner vil blive ignoreret af alarmcentralen, mens forstyrrelser i perimeterzoner vil aktivere alarmen. Røgdetektor, trådløs: En almindelig røgdetektor kombineret med en PowerCode sender i samme enhed. Ved detektering af røg vil detektoren sende en unik identifikationskode sammen med en alarmrapport og forskellige andre statusrapporter til alarmcentralen. Idet en røgdetektor tilknyttes en brandzone, vil en brandalarm blive aktiveret. Straks (INSTANT): Systemet kan Straks Tilkobles, eller Straks Nat Tilkobles, hvorved indgangsforsinkelsen annulleres for alle forsinkede zoner i den kommende tilkoblingsperiode. F.eks. kan alarmcentralen Straks Nat Tilkobles, mens du stadig opholder dig i det beskyttede område. Det er herefter alene perimeterzoner, der er aktive, og hvis du ikke forventer besøg, mens systemet er tilkoblet, vil det være en fordel at alarmen aktiveres straks. For at frakoble systemet uden at udløse alarmen, anvend tastaturet på alarmcentralen (som sædvanligvis kan betjenes uden at forstyrre en perimeterzone) eller anvend en håndsender. Tilkobling: Tilkobling af alarmsystemet er den handling, man foretager for at klargøre systemet til at afgive en alarm, hvis en zone forstyrres ved detektering af en bevægelse, åbning af dør eller vindue, afhængig af situationen. Alarmcentralen kan tilkobles på flere forskellige måder Se Fuld Tilkobling, Nat Tilkobling), Straks tilkobling og tilkobling med Frakoblingsrapport. Tvungen tilkobling: Når der er en eller flere zoner i systemet, der er forstyrrede (åbne), kan alarmcentralen ikke tilkobles. Normalt vil man afhjælpe dette problem ved at finde og udbedre årsagen til den forstyrrede zone (luk døre og vinduer). En anden måde at klare problemet på er ved at foretage en tvungen tilkobling automatisk isolering af de forstyrrede zoner. Efter tvungen tilkobling, og mens systemet stadig er tilkoblet, vil isolerede zoner, som vender tilbage til normal status (lukkes), automatisk blive beskyttet, og vil aktivere alarmen, hvis de åbnes igen. Tilladelse til at foretage en sådan tvungen tilkobling skal gives eller nægtes af montøren under programmeringen af systemet. Vende tilbage til normal: Når en detektor vender tilbage fra alarmstatus til den normale status (standby), kaldes det at vende tilbage til normal. En detektor vender automatisk tilbage til normal status efter detektering af bevægelse og er herefter klar til at detektere igen. Denne form for tilbagevenden bliver ikke rapporteret til de eksterne rapportmodtagere. En magnetkontakt vender først tilbage til normal status, når vinduet/døren i det sikrede område lukkes. Denne form for tilbagevenden bliver rapporteret til de eksterne rapportmodtagere. Zone: En zone er en del af det sikrede område under overvågning af en specifik detektor. Under programmeringen kan montøren tillade alarmcentralen at lære detektorernes identifikationskoder og tilknytte dem til den ønskede zone. Idet zonen fremtræder med både nummer og navn, kan alarmcentralen rapportere zonestatus til brugeren og registrere alle begivenheder rapporteret af zonedetektoren. Straks zoner og forsinkede zoner er kun aktive, når alarmcentralen er tilkoblet i modsætning til andre (24-timers zoner), som er aktive, uanset om systemet er Til eller Frakoblet. VISONIC LTD. (ISRAEL): P.O.B TEL-AVIV ISRAEL. PHONE: (972-3) , FAX: (972-3) VISONIC INC. (U.S.A.): 65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT PHONE: (860) , (800) FAX: (860) VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) FAX: (0870) DD5467U
73 INTERNET: VISONIC LTD POWERMAX+ USER GUIDE DD5467U (REV. 0, 5/04) DD5467U 25
PowerMax. For sikre, integrerede og interaktive hjem. Plug and Protect - problemfri installation. Kameraforbindelse giver her og nu indsigt
PowerMax For sikre, integrerede og interaktive hjem,, Plug and Protect - problemfri installation Kameraforbindelse giver her og nu indsigt Tilgængelig hvor som helst gennem Internet, mobil eller fastnettelefon
POWERMAX+ Monteringsvejledning. Fuldt overvåget trådløs alarmcentral INDHOLD DD5467IP 1
POWERMAX+ Fuldt overvåget trådløs alarmcentral Monteringsvejledning INDHOLD 1. INTRODUKTION...3 2. SPECIFIKATIONER...3 2.1 Generelle oplysninger...3 2.2 RF afsnit...3 2.3 Elektrisk specifikation...3 2.4
SSIHuset Svane Electronic Arildsvej 27, Gråmose, DK-7442 Engesvang. Tastatur med proximity standard læser Model 12 og 20
1 21.11.2010 Tastatur med proximity standard læser Model 12 og 20 Ny version December 2010 Med variabel kode længde SSIHuset Svane Electronic Arildsvej 27, Gråmose, DK-7442 Engesvang [email protected] www.svane-el.dk
POWERMAX. Programmeringsvejledning INDHOLD. Fuldt overvåget trådløs alarmcentral
POWERMAX Fuldt overvåget trådløs alarmcentral Programmeringsvejledning INDHOLD 1. INDLEDNING...2 1. 1 Generel orientering...2 1. 2 Adgang til montørmenu...2 2. PROGRAMMERING AF NY MONTØRKODE...3 3. INDLÆSE
Din brugermanual VISONIC POWERMAX http://da.yourpdfguides.com/dref/2433345
Du kan læse anbefalingerne i brugervejledningen, den tekniske guide eller i installationsguiden. Du finder svarene til alle dine spørgsmål i i brugermanualen (information, specifikationer, sikkerhedsråd,
PROFI BRUGER manual Til daglig betjening af systemet
PROFI BRUGER manual Til daglig betjening af systemet Indhold: 1 Lysdioder og symboler...3 2 Betjening af systemet...5 2.1 Tilkobling...5 2.2 Frakobling...5 2.3 Overfaldsalarm...6 2.4 Alarmstop...6 2.5
KODETASTATUR MED PROXIMITY LÆSER 125KHZ STANDARD. Varenr. 2000.1615 Valgfri kodelængde 2-6 cifre 2x6 trykknapper med blåt lys
KODETASTATUR MED PROXIMITY LÆSER 125KHZ STANDARD 16.11. 2015 Varenr. 2000.1610 Valgfri kodelængde 2-6 cifre 3x4 trykknapper med blåt lys Varenr. 2000.1615 Valgfri kodelængde 2-6 cifre 2x6 trykknapper med
QUICKVEJLEDNING til Piccolo Light
QUICKVEJLEDNING til Piccolo Light Montering 1. Piccolo Light kan installeres uden brug af kommunikation via GSM, men installeres et SIM-kort i enheden, vil man bl.a. kunne få alarmer som sms og email.
OASIS BRUGER. manual. Til daglig betjening
OASIS BRUGER manual Til daglig betjening Blinker = alarm Konstant lys = fejl Tændt = Område A tilkoblet Tændt = Område B tilkoblet Tændt = Område C tilkoblet Konstant lys = Power OK Blinkende lys = Batteri
RS 4600. Radiobaseret tyverialarm BRUGERMANUAL
RS 4600 Radiobaseret tyverialarm BRUGERMANUAL side 2 RS 4600 Radiobaseret tyverialarm Indholdsfortegnelse Ordliste... 3 1 Indledning... 4 2 Sender/Detektor muligheder... 4 3 Betjeningspanel & display...
POWERMAX. Monteringsvejledning. Fuldt overvåget trådløs alarmcentral INDHOLD
POWERMAX Fuldt overvåget trådløs alarmcentral Monteringsvejledning INDHOLD 1. INTRODUKTION...2 2. SPECIFIKATIONER...2 2.1 Generelle oplysninger...2 2.2 RF afsnit...2 2.3 Elektriske oplysninger...2 2.4
SSI-9001 IP65. Installations vejledning. SSIHuset v/svane Electronic ApS. GSM fjern kontrol og alarm system
SSI-9001 IP65 GSM fjern kontrol og alarm system Installations vejledning SSIHuset v/svane Electronic ApS Vejledning Kontakt Tænd/sluk 1 - Strømforsyning: Forbundet til egen 12V / 1.5A strømforsyning (*)
SSIHuset Svane Electronic Arildsvej 27, Gråmose, DK-7442 Engesvang. Tastatur med proximity standard læser Model 20 med Piezo tastatur
1 22.10.2013 Tastatur med proximity standard læser Model 20 med Piezo tastatur Op til 1000 brugere 3 adgangsformer 5 cifret adgangskode SSIHuset Svane Electronic Arildsvej 27, Gråmose, DK-7442 Engesvang
Brugermanual. Tyverialarmcentral med indbygget telefonsender / modem. Udgave 2
Brugermanual Tyverialarmcentral med indbygget telefonsender / modem Udgave 2 1. Oversigt Introduktion Brugerne af alarmsystemet vil blive tildelt en unik 4, 5 eller 6 cifret brugerkode. Brugerkoder benyttes
Dobbelt sender detektor med 4 kanals frekvenser. 1. Funktioner. 2. Produkt gennemgang
Dobbelt sender detektor med 4 kanals frekvenser Tak, fordi du har købt denne stråle detektor, læs venligst denne brugsanvisning omhyggeligt før installation. Forsøg aldrig at adskille eller reparere produktet.
Trådløst tastatur med ringeklokke funktion
Trådløst tastatur med ringeklokke funktion 8.12.17 Funktioner 1. En perfekt kombination af dørklokke og dør/port oplåsning, der er behageligt i brug og praktisk; 2. RF data med rullende koder for at give
Quick Start Guide til ST-3
Quick Start Guide til ST-3 Indhold Forord... 3 Modtagelse af alarmen... 4 Udpakning af alarmen... 5 Navigation i alarmens menuer... 6 Koder generelt... 7 Ændring af administrator-kode... 7 Ændring af bruger-kode...
Alarm JABLOTRON 100. Ny alarm med revolutionerende betjening
Alarm JABLOTRON 100 Ny alarm med revolutionerende betjening Betjeningspanel Betjeningspanelet kan betjenes af op til 300 brugere. Systemet indeholder både trådfaste BUS baserede og trådløse betjeningspaneler.
Installationsmanual. 2 Installering...6. 3 Installering SMS sender...7. 4 Installering PSTN/GSM sender...7. 5 Installering PSTN GSM konverter...
CS 47 Syntax Side 2 Indholdsfortegnelse 1 Introduktion...4 1.1 Funktioner...4 1.2 Forsyning...4 1.3 PSTN support...5 1.4 GSM support...5 1.5 SMS support...5 1.6 Indgange...5 1.7 Udgange...5 1.8 Password...5
Side 2 Brugermanual Premier 48, 88,168 & 640
Brugermanual Tyverialarmcentral Udgave 1 Side 2 Brugermanual Premier 48, 88,168 & 640 Indhold 1. Oversigt... 3 Introduktion... 3 Betjeningspaneler... 4 2. Brug af alarmsystemet... 6 Menuer... 6 Adgang
Trådløst tastatur Med nøglebriklæser
Trådløst tastatur Med nøglebriklæser Brugervejledning Venligst læs brugervejledningen inden montering og brug. KP700/DK-1401-1.0 Indholdsfortegnelse Introduktion Forord Medfølgende dele Produktoversigt
Manual til: Miracas DK080 GSM Tyverialarm
Manual til DK080 Indhold Forord... 4 Alarmens generelle opbygning... 5 Placering af alarmen... 7 Oversigt over alarmen... 8 Tag alarmen i brug... 9 Programering af alarmen... 10 Indtastning af egen kode...
GSM / SMS dør/port kontrol enhed
11-07-2013 GSM / SMS dør/port kontrol enhed 6 stk. Digitale indgange med egen tekst besked via SMS 4 stk. Udgange med aktivering via SMS besked 4 stk. Administrator telefonnumre der modtager SMS alarm
Brugervejledning til Alarmsystem. Model HomeSafe.
Brugervejledning til Alarmsystem. Model HomeSafe. 1 Introduktion. HomeSafe enestående infrarøde og magnetiske sensorer er integreret i dette alarmsystem. Alarmsystemet er opbygget af et central styringsanlæg,
Installationsvejledning
POWERMAX PRO Fuldt overvåget trådløst alarmsystem INDHOLDSFORTEGNELSE 1. INTRODUKTION... 3 2. SPECIFIKATIONER... 3 2.1 Generelle data... 3 2.2 RF afsnit... 4 2.3 El-data... 4 2.4 Kommunikation... 4 2.5
Side 2 CS 9452 Brugervejledning. Afsnit Navn Side. 1 Ordforklaring (terminologi) 3. 3 Betjeningsknapper og -lamper 6
BRUGERVEJLEDNING Side 2 CS 9452 Brugervejledning INDHOLDSFORTEGNELSE: Afsnit Navn Side 1 Ordforklaring (terminologi) 3 2 Introduktion 5 3 Betjeningsknapper og -lamper 6 4 Fuld tilkobling, Deltilkobling,
Beskyttelse Døre, fronthjelm, bagagerum og kabine, samt startblokering (hvis monteret)
Kære Kunde Vi takker for valget af vores system, og vi kan oplyse, at dette produkt er et teknisk avanceret alarmsystem, der lever op til de ydelsesmæssige standarder, som er fastsat af bilproducenterne,
Programmering af CS7050 TCP/IP modul
Comfort CSx75 Programmering af CS7050 TCP/IP modul Introduktion CS7050 TCP-IP modulet er en fuldt integreret enhed, som tilbyder nye funktioner til Comfort seriens centraler i form af TCP/IP Ethernet forbindelse
Introduktion til Guardsman ctc 1132
Introduktion til Guardsman ctc 1132 Tillykke med dit nye Guardsman alarmsystem. I denne manual kan du læse, hvordan systemet placeres, indstilles og anvendes. Følgende trin vil blive gennemgået: 1. Montering
Vildtkamera DTC-530V.
Vildtkamera DTC-530V. Indhold fortegnelse......... 1 Kom godt i gang.........2 Information......... 2 Anvendelse......... 3 Fjernbetjening...... 3 Hukommelse kort......... 4 Quick Start...... 4 Isæt batterier.........
BRUGERVEJLEDNING CP-508LCD ALARMCENTRAL
ALPHATRONICS DANMARK BRUGERVEJLEDNING CP-508LCD ALARMCENTRAL Version 4.2 INDHOLDSFORTEGNELSE BETJENING... side 2 TIL- OG FRAKOBLING... side 3 TILKOBLING NIVEAU 1... side 4 TIL- OG FRAKOBLING NIVEAU 2...
Betjeningsvejledning. Nødhjælps Alarm System NAS-100
Betjeningsvejledning Nødhjælps Alarm System NAS-100 Indholdsfortegnelse Egenskaber... 02 Vorbereitung der Nutzung... 03 Indsæt simkort... 03 Tilslut alle de enheder, du har brug for... 03 Strøm... 03 Udfør
Manual til Elegant DK190
Manual til Elegant DK190 Indhold Forord... 4 Alarmens generelle opbygning... 5 Placering af alarmen... 7 Oversigt over alarmen... 8 Forside... 8 Bagside... 9 Tag alarmen i brug... 10 Programering af alarmen...
1 Generelt... 3. 2 Tilkoblingsmuligheder... 4 2.1 Normal tilkobling... 4 2.2 Hurtig tilkobling... 4 2.3 Tilkobling med udkobling af grupper...
Brugermanual Side 2 Atlas 8 PLUS Indholdsfortegnelse 1 Generelt... 3 2 Tilkoblingsmuligheder... 4 2.1 Normal tilkobling... 4 2.2 Hurtig tilkobling... 4 2.3 Tilkobling med udkobling af grupper... 5 3 Frakobling...
V. 2. 6 ERHVERVS TYVERI ALARM BRUGER VEJLEDNING. Alarmfirma: R S - 2 4 0
R S - 2 4 0 V. 2. 6 ERHVERVS TYVERI ALARM Ver. 2-6 Rev. 5. april 2001. Dokument : RS-240b / FG Alarmfirma: BRUGER VEJLEDNING 2 15 INDHOLDSFORTEGNELSE : Denne vejledning beskriver de generelle betjeningsmuligheder
Multi kanal GSM porttelefon med adgangs kontrol
Multi kanal GSM porttelefon med adgangs kontrol Model: MCI-3000V1 Funktioner: Metal tastatur. Robust anti-vandal enhed. Rustfrit stål dørstation. Nem installation kun fire ledninger. Anti-Vandal højttaler
GSM port styring 400 brugere
1 GSM port styring 400 brugere SMS alarm, temperatur og fjernkontrol system 16 brugere til at modtage alarmbeskeder via SMS Software vejledning SSIHuset Svane Electronic ApS Arildsvej 27, Gråmose, DK-7442
Programmering af trådløse modtagere (RF)
Comfort CSx75 Programmering af trådløse modtagere (RF) Introduktion Centralerne CSx75 kan udvides med trådløse (RF) modtagere på 868 MHz og 433 MHz. Når en RF modtager er installeret på centralen, kan
Programmering af CS7002 GSM/GPRS modul Version 5
Comfort CSx75 Programmering af CS7002 GSM/GPRS modul Version 5 Introduktion CS7002 GSM/GPRS modulet er en fuldt integreret enhed som kan sende alarmer trådløst enten via GSM eller GPRS nettet. Der er desuden
Brugervejledning Side 1
Deluxe trådløs relæboks Brugervejledning www.gsmteknik.dk 04.06.2019 Side 1 Indholdsfortegnelse 1. Tekniske specifikationer 3 2. Indkodning med alarm 4 3. Indkodning af RFID brikker. 5 4. Sletning af RFID
GSM / SMS port kontrol enhed
26.1.2011 GSM / SMS port kontrol enhed 6 stk. Digitale indgange med egen tekst besked via SMS 4 stk. Udgange med aktivering via SMS besked 4 stk. Administrator telefonnumre der modtager SMS alarm besked
GSM Dørtelefon. Installation manual. Bruger manual. Gennemlæs omhyggeligt denne manual før installation og ibrugtagning af dette produkt.
GSM Dørtelefon Installation manual Bruger manual Gennemlæs omhyggeligt denne manual før installation og ibrugtagning af dette produkt. Tlf.: +45 86161617 Mobil: +45 40200001 Side 1 GSM Dørtelefon Version
AlphaVision ML Hybrid alarmanlæg. Grundlaget for en pålidelig sikring af Deres hus, virksomhed eller lokaler
AlphaVision ML Hybrid alarmanlæg Grundlaget for en pålidelig sikring af Deres hus, virksomhed eller lokaler Fleksible sikkerhedsløsninger Fra beboelse til erhverv. AlphaVision ML alarmanlæg tilbyder, med
Beskrivelse af tryghedsalarmen
Denne vejledning fungerer som en hurtig og nem brugervejledning på dansk, oversat af GSM Teknik ApS. Skal man bruge alle detaljer, henvises til den engelske vejledning, der medfølger i kassen. Beskrivelse
Trådløst Alarm System. Med indbygget GSM modem. Brugsanvisning V1.01
Trådløst Alarm System Med indbygget GSM modem Brugsanvisning 1 Indhold Side 2 - Forord Side 3 - Alarm oversigt Side 4 - Opstart af alarm Side 4 - Programmering af alarmcentral Side 4 - Indtastning af kode
på Sterling 10 Brugermanual Bemærk! betjeningspanelet er i manualen angivet som FUNC
Sterling 10 Brugermanual Bemærk! Tasten FUNC på Sterling 10 betjeningspanelet er i manualen angivet som Side 2 Sterling 10 Indholdsfortegnelse 1 Bruger- og master-faciliteter... 3 1.1 Generelt... 3 1.2
QUICKVEJLEDNING til multiguard DIN6. Montering
QUICKVEJLEDNING til multiguard DIN6 Montering 1. Klargør et SIM-kort, så pinkoden er 1234 eller deaktiveret. Monter kortet i enheden. Enheden har nu 1234 som password eller kører uden password. Kortet
Opstart af central & betjeningspanel
Comfort CSx75 Introduktion Denne kvikguide viser de første trin til at starte centralen. Kvikguiden beskriver hvordan betjeningspanelet og centralen fabriksindstilles, og hvordan man indstiller dato/tid,
Programmering CS320-strømforsyning
Comfort CSx75 Programmering CS320-strømforsyning Introduktion Dette eksempel forklarer hvordan CS320-strømforsyningen kan anvendes sammen med centrale. Op til otte CS320-strømforsyninger kan tilsluttes
INTEGRA BRUGER MANUAL
NOMEX SCANDINAVIA A-S INTEGRA BRUGER MANUAL SATEL Version 1.7 - juni 2010 INDHOLD 1. Beskrivelse af alarmsystemets funktioner...3 2. Tilkobling af ét område...3 3. Tilkobling af flere områder...3 4. Udkobling
Trådløs Radio modtager
Trådløs Radio modtager Installations vejledning for type: RRA85-C2V, 2 relæer, 230VAC RRA85-C2P, 2 relæer, 12/24 AC/DC RRA85-C4V, 4 relæer, 230VAC RRA85-C4P, 4 relæer, 12/24 AC/DC IP 44 DanZafe 1 I. PRODUKTBESKRIVELSE
Bruger manual for Trådløst Basis Alarmsystem FS222E
Bruger manual for Trådløst Basis Alarmsystem FS222E 1 Denne brugermanual fortæller hvordan Fronti Basis alarm betjenes via tastaturet med og uden nøglebrikker, app og sms fjernstyring. De sidste 3 sider
Manual til PRO DK180
Manual til PRO DK180 Indhold Forord... 4 Alarmens generelle opbygning... 5 Placering af alarmen... 7 Oversigt over alarmen... 8 Tag alarmen i brug... 10 Programering af alarmen... 11 Indtastning af egen
GT2000 GT2000. Brugervejledning
Brugervejledning www.gsmteknik.dk 20.2.2019 Side 1 Tekniske specifikationer Spænding Strømforbrug GSM frekvenser Antal kombi indgange Belastning relæudgang Arbejdstemperatur 9-30 VDC typisk 12VDC eller
GSM ALARM BASIC. Brugervejledning dansk. Version 1. Side
GSM ALARM BASIC Brugervejledning dansk Version 1 Side Tekniske data Spænding/strøm Standby strøm Alarm strøm Trådløs frekvens GSM frekvens Back-up Batteri Relæudgang (NO) 9-12V DC / 500mA
INSTALLATIONSMANUAL TIL GARAGEPORT ÅBNER GA 1000
INSTALLATIONSMANUAL TIL GARAGEPORT ÅBNER GA 1000 INSTALLATIONS MANUALEN SKAL GENNEMLÆSES OMHYGGELIG FØR IBRUGTAGNING ADVARSEL FOR SIKKER INSTALLATION Inden installation af automatikken skal balance fjederen
MANUAL FANTRONIC 20AMP. TRIAC SLAVEENHED FOR VENTILATION VER:FAN 1.1 SKIOLD GØR EN FORSKEL!
MANUAL SKIOLD GØR EN FORSKEL! FANTRONIC 20AMP. TRIAC SLAVEENHED FOR VENTILATION VER:FAN 1.1 981 002 317 Ver. 01 11-03-2013 Indhold 1. INTRODUKTION... 4 2. BESKRIVELSE FANTRONIC... 5 2.1 SÅDAN FUNGERER
Brugervejledning til intelligent alarmsystem
Brugervejledning til intelligent alarmsystem Tak for valget af vores produkter. Du bedes læse vejledningen grundigt, før du tager dem ibrug. Indholdsfortegnelse 1. OVERSIGT 1.1. Indledning... 1 1.2. Komponenter...
GSM SMS Modem MODEL: SA RTU-1 V1.01
GSM SMS Modem MODEL: SA RTU1 V1.01 Brugervejledning Indgange: Der er fire indgange på modulet. De kan programmeres som normale indgange. De kan programmeres som tæller. Udgange: Der er en udgang på modulet
POWERMAX+ Brugervejledning. Fuldt overvåget trådløs alarmcentral INDHOLD DD5467U 1
POWERMAX+ Fuldt overvåget trådløs alarmcentral INDHOLD 1. INTRODUKTION...4 1.1 Oversigt...4 1.2 Systemets Faciliteter...5 1.3 Fagudtryk...5 1.4 Symboler anvendt I vejledningen...5 1.5 Taster på Alarmcentralen...5
Alarmen er frakoblet. Easy Series Alarmcentral Gør sikkerhed enkel med wlsn* * wireless Local SecurityNetwork (trådløst lokalt sikkerhedsnetværk)
Alarmen er frakoblet Easy Series Alarmcentral Gør sikkerhed enkel med wlsn* * wireless Local SecurityNetwork (trådløst lokalt sikkerhedsnetværk) 2 Sikkerhed i første række Selvfølgelig vil du sørge for
Alarmsystem. INSTALLATIONSVEJLEDNING Kun for kvalificerede teknikere
10034576 Alarmsystem INSTALLATIONSVEJLEDNING Kun for kvalificerede teknikere ADVARSEL! Producenten fralægger sig ethvert ansvar for og giver ingen garanti i forbindelse med fejl og fejlfunktioner, der
INSTALLATIONSMANUAL TIL GARAGEPORT ÅBNER
INSTALLATIONSMANUAL TIL GARAGEPORT ÅBNER INSTALLATIONS MANUALEN SKAL GENNEMLÆSES OMHYGGELIG FØR IBRUGTAGNING ADVARSEL FOR SIKKER INSTALLATION Inden installation af automatikken skal balance fjederen på
4. Tilslut batteri backup i centralen til dens konnekter. I tilfældet af en alarm indtast Masterkoden (default 1234) for at afstille alarmen
Installations punkter. 1. Monter centralen hvor man ønsker den placeret 2. Monter forsyningskablet 3. Tilslut Ethernet kablet og/eller SIM kortet til kommunikations modulet 4. Tilslut batteri backup i
Brugermanual Beskrivelse af betjeningspanel med kontrolpanel
Brugermanual Beskrivelse af betjeningspanel med kontrolpanel For den mest bekvemme kontrol / styring og status af Jablotron 100 systemet, tilbydes der forskellige former for betjeningspaneler. Styring
Trådløst betjeningspanel Betjeningsvejledning
Trådløst betjeningspanel Betjeningsvejledning 2017V 1.0 Indhold 02 2 3 Kom godt i gang Pakkens indhold Oversigt / funktioner 5 6 7 8 11 11 12 13 14 15 16 Installation Betjening Brug med nøglebrik Indstillinger
Manual KlimaC SMS Box. Dioder for fjernbetjening skal pege mod varmepumpen (afstand 6 m.)
Manual KlimaC SMS Box Dioder for fjernbetjening skal pege mod varmepumpen (afstand 6 m.) Opstart Isætning af SIM kort: SIM-kortet SKAL være uden Pin-kode, koden fjernes nemmest ved at isætte SIM-kortet
OASIS. Alarmsystem. OASIS Alarm - den ideelle sikring af virksomhed og hjem. OASIS Meget mere end et trådløst alarmsystem
OAI Alarmsystem OAI Alarm - den ideelle sikring af virksomhed og hjem OAI Meget mere end et trådløst alarmsystem OAI giver dig sikkerhed og tryghed En OAE af sikkerhed Et OAI alarmsystem er den ideelle
KomGodtIgang-guide for Infinite Prime
KomGodtIgang-guide for Infinite Prime 19.05.11 KomGodtIgang-guiden, er tænkt som en hjælp til at spare installationstid for montøren ved 1.gangs-opstart, men følg altid de forskellige manualers anvisninger,
Automatisk satellit overvågning af
Automatisk satellit overvågning af dine ejendele InteT abonnement eller gebyr Få adgang til al information direkte via mobiltelefon eller Internet Bevægelses sensor - autosporing samt aflytning Markedets
POWERMAX+ Brugervejledning. Fuldt overvåget trådløs alarmcentral INDHOLD DD5467U 1
POWERMAX+ Fuldt overvåget trådløs alarmcentral Brugervejledning INDHOLD 1. INTRODUKTION...4 1.1 Oversigt...4 1.2 Systemets Faciliteter...5 1.3 Fagudtryk...5 1.4 Symboler anvendt I vejledningen...5 1.5
BRUGERVEJLEDNING CENTRALENHED
BRUGERVEJLEDNING CENTRALENHED Side 1 til centralenhed Introduktion Centralenheden styres og indstilles via det online kontrolpanel. Det er centralenheden, som sender og modtager signaler fra alle sensorerne,
BRUGERVEJLEDNING SIGNALFORSTÆRKER
BRUGERVEJLEDNING SIGNALFORSTÆRKER Side 1 til signalforstærker Introduktion Signalforstærkeren fra LOCKON bruges til at forlænge og forstærke det trådløse signal fra centralenheden ud til de forskellige
Duplex 312 FJERNAKTIVERING, OVERVÅGNING OG STYRING Brugermanual Varenr. 009012
Brugermanual, Duplex 312, Side 1 Duplex 312 FJERNAKTIVERING, OVERVÅGNING OG STYRING Brugermanual Varenr. 009012 Sådan virker Duplex 312 Funktionsoversigt Brugermanual, Duplex 312, Side 2 GSM styring og
IP & GPRS IP (+ GPRS) transceivere
IP & GPRS IP (+ GPRS) transceivere IP/GPRS serie IP ER FREMTIDEN FRA ANALOG TIL DIGITAL Den perfekte løsning i enhver situation Transmission af alarminformation via IP at slutbruger er nødt til at udskifte
Installation og Brugermanual for GRIPO 5100 Alarmsystem
v12082008 Installation og Brugermanual for GRIPO 5100 Alarmsystem 5101 Hovedstation Dette GRIPO alarmsæt indeholder følgende: 1 stk GRIPO 5101 Hovedstation 1 stk GRIPO 5107 Trådløs fjernbetjening 1 stk
PARAGON ε. Brugermanual
PARAGON ε Brugermanual Side 2 Pyronix Paragon ε Indholdsfortegnelse Side 1 Indledning...3 2 Faciliteter...4 3 Funktionsbeskrivelse...5 3.1 Operationstilstande...5 3.2 Ind- og udgangstilstande...6 4 Zoner...7
SPIDER Quick guide. DATO: August 2017 FORHANDLER: WASYS A/S. Langebjergvænget Roskilde
SPIDER Quick guide DATO: August 2017 FORHANDLER: WASYS A/S Langebjergvænget 18 4000 Roskilde +45 7221 7979 Indhold Om SPIDER... 3 Funktioner ved SPIDER... 3 Spændingsforsyning... 3 Installation og fysiske
GSM port kontrol med samtale anlæg
12-04-2011 SSI 2600.8001 GSM porttelefon system Samtaleanlæg og 1000 telefon numre med opkald for åbning Alt i en kontrol enhed til udendørs installation SSIHuset Svane Electronic ApS Arildsvej 27, Gråmose,
SimPal-T4. GSM Stikkontakt. SimPal T4 GSM stikkontakt. Den korte opstart
1 SimPal-T4 GSM Stikkontakt Den korte opstart SimPal T4 GSM stikkontakt 2 Tak, fordi du har købt SimPal-T4. SimPal T4 GSM stikkontakt er en fjernbetjent stikdåse, der består af et GSM modul. Strømforsyningen
QUICKVEJLEDNING til multiguard Master IO. Montering
QUICKVEJLEDNING til multiguard Master IO Montering 1. Klargør et SIM-kort, så pinkoden er 1234 eller deaktiveret. Monter kortet i enheden. Enheden har nu 1234 som password eller kører uden password. Kortet
READX-EM&MF WIEGAND slave kodetastatur & proxlæser
READX-EM&MF WIEGAND slave kodetastatur & proxlæser Installations manual Ver. 2018-09-24 INDHOLD Introduktion 3 Kassens indhold 4 Installation 5 Tilslutninger 6 Wiegand dataformat 7 Vare nummer 8 Kodeliste
BRUGERVEJLEDNING BETJENINGSPANEL
BRUGERVEJLEDNING BETJENINGSPANEL Side 1 til betjeningspanel Introduktion Du kan betjene din alarm med det trådløse betjeningspanel. Det placeres ved hjemmets hoveddør, så det er let at slå alarmen til
ELCANIC A/S. ENERGY METER Type ENG110. Version 3.00. Inkl. PC program: ENG110. Version 3.00. Betjeningsvejledning
ELCANIC A/S ENERGY METER Type ENG110 Version 3.00 Inkl. PC program: ENG110 Version 3.00 Betjeningsvejledning 1/11 Generelt: ELCANIC A/S ENERGY METER Type ENG110 er et microprocessor styret instrument til
MEN-001-B GARAGEPORTÅBNER MONTERINGSVEJLEDNING
MEN-001-B GARAGEPORTÅBNER MONTERINGSVEJLEDNING INDHOLDSFORTEGNELSE Sikkerhedsforanstaltninger.....1 Nødvendigt værktøj...1 Montering af garageportåbneren...2-6 Montering af skinnerne..7-8 Stramning af
CP1000. Brugermanual
secure open Kode & Proximity CP1000 Mykey - Art. Nr: 480015 (sort), 480016 (hvid) Classic - Art. Nr.: 482015 (sort), 482016 (hvid) Brugermanual CP1000_usermanual_DANjun15 Conlan ApS Speditørvej 2A DK-9000
Svane Electronic Timer universal med 8 funktioner 1
Svane Electronic Timer universal med 8 funktioner 1 Digital timer print modul 12V 2000.2231 Multi funktions timer med 8 funktioner, anvendelig i mange installationer, forsyning 12VDC drift. Printet har
BRUGERVEJLEDNING VANDSENSOR
BRUGERVEJLEDNING VANDSENSOR Side 1 til vandsensor Introduktion Vandsensoren er designet til at opdage vand, f.eks. ved oversvømmelser i din bolig. Den kan placeres alle steder, hvor der kan være risiko
Kode & Mifare CM1000. Brugermanual
secure open Kode & Mifare CM1000 Mykey - Art. Nr: 480010 (sort), 480011 (hvid) Classic - Art. Nr.: 482010 (sort), 482011 (hvid) Brugermanual CM1000_usermanual_DANjun15 Conlan ApS Speditørvej 2A DK-9000
QUICKVEJLEDNING. Montering
QUICKVEJLEDNING Montering 1. Klargør et SIM-kort, så pinkoden er 1234 eller deaktiveret. Monter kortet i enheden. Enheden har nu 1234 som password eller kører uden password. Kortet vendes som vist nedenfor.
Parallelbox 2. Installationsmanual
Parallelbox Installationsmanual Side Parallelbox Indholdsfortegnelse. Generelt.... Forbindelser.... Programmering...4. Standardprogrammering...4. Lysdiodeindstilling for aktiv indgang (00)...5. Lysdiodeindstilling
(2 DØRE, 100 NØGLER)
BESKRIVELSE Vprox 100 er et avanceret adgangskontrol-system baseret på Videx unikke Coded Key, der giver mere end 4 milliarder kombinationer. Systemet kan kontrollere to uafhængige døre og gemme op til
Svane Electronic Universal timer med 4 relæer og et valg af 18 funktioner hver 1. 4 kanals timer med 18 funktioner
Svane Electronic Universal timer med 4 relæer og et valg af 18 funktioner hver 1 4 kanals timer med 18 funktioner 2000.2238 Vi sikrer en høj kvalitet sammen med vores samarbejdes partnere! Vi udveksler
Jablotron OASIS alarmpakke trådløs (868 MHz) alarmpanel og trådløse sensorer
Landsbylauget har indhentet et forslag til en tyverialarm fra Hjortteknik i Fløng. Hej Michael eklager den lange ventetid. Her er tilbud på et på alarmanlæg som kan udvides efter behov. Vedhæftet er datablad
Din brugermanual VISONIC POWERMAX PRO http://da.yourpdfguides.com/dref/3226465
Du kan læse anbefalingerne i brugervejledningen, den tekniske guide eller i installationsguiden. Du finder svarene til alle dine spørgsmål i VISONIC POWERMAX PRO i brugermanualen (information, specifikationer,
CM 1000 Kode og MIFARE Læser Art. Nr.: 460xxx Brugermanual
CM 1000 Kode og MIFARE Læser Art. Nr.: 460xxx Brugermanual CM1000v.1 Manual DANdec12 Side 2 CM 1000 Indholdsfortegnelse Side 1. Introduktion... 3 2. Installation... 3 3. Programmering af Brugere... 4 3.1
RS-210 ERHVERS TYVERI ALARM BRUGER VEJLEDNING. Alarmfirma:
RS-210 ERHVERS TYVERI ALARM Alarmfirma: Ver. 2-1 Rev. 01.03.2001 Dokument: RS-210b/F.G. BRUGER VEJLEDNING 2 11 INDHOLDSFORTEGNELSE: Egne notater : Denne vejledning beskriver de generelle betjeningsmuligheder
