Luchtbehandelingskasten TIME EC en DV

Relaterede dokumenter
Oversigt for aggregat nr. 6, Danvent DV TIME 20

TIME ec. Air Handling Units

Oversigt for aggregat nr. 1

Oversigt for aggregat nr. 2

Ventilatorer Brand- og røgprodukter Ventilationsaggregater Luftfordeling Tilbehør Ventilationssystemer. TIME ec. Ventilationsaggregater

Time aggregaterne er med komplet og fuldt integreret automatik baseret på Systemair E28 regulatoren.

Ventilatorer Brand- og røgprodukter Ventilationsaggregater Luftfordeling Tilbehør Systemløsninger. TIME ec. Ventilationsaggregater

Energi klasse A I henhold til Eurovent energi klassifikation for aggregater. Beskrivelse kan downloades fra

Oversigt for aggregat nr. 10

Ventilatorer Brand- og røgprodukter Ventilationsaggregater Luftfordeling Tilbehør Systemløsninger. TIME ec. Kompakt ventilationsaggregat

Fjernbetjening Flex Teknisk manual

Navn: DVG V 560EC/F400 varenr.: 95135

Oversigt for aggregat nr. 10

Navn: DVG V 450EC/F400 varenr.: 95257

Danvent DV og TIME. Systemair E28 Styring. Betjeningsvejledning. Ændring af tid, temperatur og luftydelse. Version 3.1

God luftkvalitet giver God livskvalitet!

Ventilatorer Brand- og røgprodukter Ventilationsaggregater Luftfordeling Tilbehør Systemløsninger DVU-HP. Integreret reversibelt varmepumpesystem

Montage og brugsanvisning

God luftkvalitet giver God livskvalitet!

Genius laderegulator Monterings og brugervejledning

DUKA PLUS L180E. DUKA Ventilation. din tryghed for et sundt indeklima

Installatør Guide. CTS6000 Webcontrol

Alarm og overvågning for din sikkerhed

WIO200A Water in oil sensor

Navn: DVG V 450EC/F400 varenr.: 95257

Fjernbetjening Flex Service manual

Optima-GO volumenstrømsregulator

Oversigts billedet: Statistik siden:

Navn: DVG V 355EC/F400 varenr.: 95256

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL UNI-EL Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

VENTILATIONSAGGREGAT VUT 160V/350VB/550VB EC

SPEED-Commander Frekvensomformer. Program nr. 1 Software version PI-regulering

BETJENINGSVEJLEDNING. Total varmeveksler HRV (Heat Reclaim Ventilation) (Loftsmonteret kanal type)

Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper

VENTILATIONSAGGREGAT VUT 160PB/350PB EC

FireBUS PARKERINGSVENTILATION

Overvågning af punktsug, URANOS LOCAL EXHAUST GUARD

SFPe, with dimensional filter pressure drop Varmebatteri Luft 4.5 kw /22.0 C 60/25 C kpa l/s - 1/2" / 1/2" Rørtilslutning

FlexValve - Industrivej 2 - DK 4241 Vemmelev - Tel

VENTILATIONSAGGREGATER TIL KOMFORTVENTILATION

FireBUS BRANDSIKRINGSAUTOMATIK For spjældsikrede og røgventilerede systemer

Ventilationsaggregater Danvent TIME og Danvent DV

CLIMATIX TM. GBS Kontrolboks GBS Display Installations manual

Topvex VAV-konvertering

Slot diffusers. Slot diffusers LD-17, LD-18

Ventilationsaggregater. Systemair Access. Automatik til Geniox ventilationsaggregater

LAD NATUREN KOMME INDENFOR

LAD NATUREN KOMME INDENFOR

Tryk Transmitter Model LV52X til trykmåling og overvågning med alarm af Lean Process Ventilation

PAR-555-SYS Konstanttrykregulering

EX-EC ikke tilsluttet bus i FanIO stik B, Fejl i buskabel, Buskabel i EX-EC monteret i stik B i stedet for A

VAV FUNKTION. Instruktionsmanual 2

CLIMATIX TM. GBS Kontrolboks GBS Display Installations manual

Ventilationsaggregater. Topvex FR, SR, TR

Rumtryksregulator, URANOS ROOM PRESSURE REGULATOR

LAD NATUREN KOMME INDENFOR

Dr.Heron med tilslutningsprint DCT

Fjernbetjening Flex Teknisk manual. Symboler på luftretning


Oversigt for aggregat nr. 10

Ventilatorer Brand- og røgprodukter Ventilationsaggregater Luftfordeling Tilbehør Ventilationssystemer. Topvex SR, TR og SC. Ventilationsaggregater

Manual. IMage Elektronisk styring med varmeregulering. Type

Tilslutning- og programmeringseksempler

Engine Powered Forklift ton

Dr.Sherlock INSTALLATION. 1.0 Diagram TEMPERATUR - OVERVÅGNING

Systemair Connect. Opsætning

Vejledning i installation Gældende fra 4. Maj Version 5. Indendørs version

MIO Modul (Modbus Input Output) til EXact automatik

LAD NATUREN KOMME INDENFOR

Alde Smart Control App

Fjernbetjening Stouch Teknisk manual. Symboler på luftretning på anlæg

Oversigt for aggregat nr. 3

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS /15 (OSH) 2015 OJ Electronics A/S


Varmepumpe udviklet specielt til mindre havebassiner

LAD NATUREN KOMME INDENFOR

LOFTHÆNGTE AGGREGATER MLO

TIMEec styresystem. Fabrikant: leverandør: SystemAir A/S, Systemair A/S, Danmark Ved Milepælen Hasselager. Dokumentet er inddelt som følgende:

Axel Kiers Vej Højbjerg Tlf.: Mobil:

VENTILATIONSAGGREGAT VUT 160V/350VB/550VB EC

ØLAND ØLAND. Drift og vedligeholdelse (bruger) Brugervejledning nr. AHU-250-brugervejledning Luftbehandlingsaggregat AHU-250-M-EC

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

Billede. Boksventilator BVB. Generel funktionsbeskrivelse

MultiProgrammer Manual

INDHOLD: VEX35DV til decentral boligventilation > Generelt. VEX35DV til decentral boligventilation > Energi. VEX35DV til decentral boligventilation >

hjertestarterskab/aed - din garanti for en tryg opbevaring!

111570DK CS60. Tilslutnings- og konfigurationsvejledning Styringsautomatik

FSystem beskrivelse PAR 200 CLOCK

Ventilationsaggregater Danvent TIME og Danvent DV

CA hjertestarterskab HSS101 med AED sensor

OVERVÅGNINGSSYSTEM FICO-64» MONTAGEANVISNING

Beskrivelse af vejrstation OM1 NETLON NETLON. Dette dokument indeholder en beskrivelse af en vejrstation OM1 fra Netlon.

WEA-Base Brugervejledning til vejetransmitter

System JA 1000 Stand-alone styring for befugter eller affugter for relativ fugtighed og eller dugpunkt.

Hjertestarterskab/AED - din garanti for en tryg opbevaring!

E X H A U S T S. EXHAUSTS Palby Marine. De neopreen balg is RINA goedgekeurd. system is suitable for both sail and. bruges både på sejl- og motorbåde.

WI180C-PB. Online-datablad

Hudevad P200. Technical datasheet

hjertestarterskab/aed - din garanti for en tryg opbevaring!

MANUAL FANTRONIC 20AMP. TRIAC SLAVEENHED FOR VENTILATION VER:FAN 1.1 SKIOLD GØR EN FORSKEL!

Transkript:

Ventilatoren Compacte WTW-units Modulaire luchtbehandelingskasten Luchtverdelingsproducten & Brandbeveiliging Luchtbehandelingskasten TIME EC en DV Servicevriendelijk en eenvoudig in gebruik

2 Luchtbehandelingskasten TIME EC en DV Servicevriendelijk en eenvoudig in onderhoud De luchtbehandelingskasten TIME EC en DV van Systemair hebben kortgeleden een service-upgrade ondergaan. Hieronder volgt een korte samenvatting van de verschillende verbeteringen voor een nog servicevriendelijker en eenvoudiger bedrijf. Hijsogen (standaard) De luchtbehandelingskasten TIME EC en DV met basisconsole zijn nu standaard voorzien van nieuwe, stevige hijsogen. Dit vereenvoudigt en versnelt de plaatsing van de kast op de bouwplaats, ongeacht waar deze wordt geïnstalleerd.

Luchtbehandelingskasten TIME EC en DV 3 Afscherming van ventilatorsecties en warmtewiel (standaard) De installatie, de service en het onderhoud van de luchtbehandelingskasten moeten zo risicoarm mogelijk zijn. Daarom zijn de ventilatorsecties nu standaard afgeschermd. Het warmtewiel is alleen afgeschermd bij de DV 50 of groter. De afscherming kan eenvoudig met gereedschap worden verwijderd. Bediening van frequentieomvormers via het bedieningspaneel De frequentieomvormers kunnen vanaf nu worden bediend via een bedieningspaneel dat zich aan de buitenkant van de inspectiedeur bevindt. Dankzij deze optie is het eenvoudiger om instellingen van de frequentieomvormers te wijzigen zonder de luchtbehandelingskast te openen. Secties met verlichting Het is nu mogelijk om voor de meeste secties verlichting te bestellen. De verlichting is bedoeld voor de secties waar service en onderhoud worden verricht.

4 Luchtbehandelingskasten TIME EC en DV TIME EC AHU N o 07.02.339 DANVENT DV 10-240, TIME 10-40 TIME EC is een standaard luchtbehandelingskast met EC-motoren en geïntegreerd regelsysteem. TIME EC is verkrijgbaar in 6 maten met luchtstromen van 750 tot 12.500 m 3 /u. TIME EC wordt geleverd in 2 versies met warmtewiel en 2 versies met tegenstroomwarmtewisselaar. TIME EC is gebaseerd op de welbekende technologie van Systemair voor de productie van luchtbehandelingskasten op basis van ruim 40 jaar ervaring. TIME EC is eenvoudig te dimensioneren en bestellen. TIME EC voldoet aan DS 428.4 TIME EC met warmtewiel, luchtstromen 750-12.500 m 3 /u in 6 groottes 500 700 1000 1500 2000 3000 5000 10000 15000 m 3 /h Met koeling Airflows min - max TIME ec 40 TIME ec 30 TIME ec 25 TIME ec 20 TIME ec 15 TIME ec 10 0,15 0,2 0,3 0,4 0,7 1 2 3 4 m 3 /s Aanbevolen luchtstroom voor TIME EC met externe druk van 250 Pa en max. SFP 2.1 kw/(m 3 /s) in combinatie met warmtewiel, warmwaterbatterij en koeler. Let op: toevoer- en afvoerkleppen, warmwaterbatterijen en koeler zijn extra opties. Andere combinaties en precieze waarden moeten worden berekend in SystemairCAD. TIME EC met tegenstroomwarmtewisselaar, luchtstromen 750-9.900 m 3 /u in 6 groottes 500 700 1000 1500 2000 3000 5000 10000 15000 m 3 /h Met koeling Airflows min - max TIME ec 40 TIME ec 30 TIME ec 25 TIME ec 20 TIME ec 15 TIME ec 10 0,15 0,2 0,3 0,4 0,7 1 2 3 4 m 3 /s Aanbevolen luchtstroom voor TIME EC met externe druk van 250 Pa en max. SFP 2.1 kw/(m 3 /s) in combinatie met tegenstroomwarmtewisselaar, warmwaterbatterij en koeler. Let op: toevoer- en afvoerkleppen, warmwaterbatterijen en koeler zijn extra opties. Andere combinaties en precieze waarden moeten worden berekend in SystemairCAD.

Luchtbehandelingskasten TIME EC en DV 5 Onderdelen 1 Warmtewiel wordt gebruikt als er veel behoefte is aan warmteterugwinning. Tegelijkertijd kan vocht worden onttrokken aan de warme afvoerlucht. Het systeem is zeer energiezuinig en heeft maar weinig ruimte nodig vanwege de korte lengte. Efficiency tot 85%, variabele draaisnelheid voor aangepaste efficiency, spoelzone plus alarm bij onbedoelde stop. 2 Tegenstroomwarmtewisselaar wordt gebruikt als er speciale eisen worden gesteld aan de scheiding van de luchtstromen, bijvoorbeeld om geuroverdracht naar de aanvoerlucht te voorkomen. Aangezien vocht niet tussen de luchtstromen kan worden overgedragen, kan deze warmtewisselaar worden gebruikt om te ontvochtigen. Efficiency tot 90%, temperatuursensor en modulerende bypassklep voorkomt ijsvorming. 3 EC-motoren, laag energieverbruik, goede regelmogelijkheden, hoge efficiency ook bij lage belasting, laag geluidsniveau en korte lengte. Standaard voorzien van afscherming. 4 Toevoer- en afvoerafsluiters, luchtdichtheidsklasse 3 (EN 1751), aërodynamische klepbladen van geëxtrudeerd aluminium met rubber afdichting, stalen stangen en koperen lagers, aandrijvingen; aan/uit of veerteruggang (extra optie). 1 5 4 5 Toevoer- en afvoerfilters, zakfilters in filterkwaliteit F7/F5 (EN 779), vastgezet met filterrails om de dichtheid te garanderen (EN 1886), hendel voor eenvoudig vervangen, alarm als de filters moeten worden vervangen. 6 Warmwaterbatterij, ontwikkeld voor temperaturen tot 100 C en druk tot 10 bar. De batterij is tegen vorst beveiligd (extra optie). 7 Geïntegreerd regelsysteem, af fabriek geïnstalleerd, zie pagina 5. 8 Behuizing voldoet aan luchtdichtheidsklasse L2, heeft gesloten frameprofielen van staal en panelen met 50 mm isolatie. 9 Steunpoten van sterk gegalvaniseerd staal en voorzien van verstelbare pootjes. 3 7 8 4 5 6 3 7 9 2 5 4 5 8 4 3 7 6 3 7 9

6 Luchtbehandelingskasten TIME EC en DV Flexibele luchtbehandelingskasten Bouwen vraagt in de toekomst om zeer flexibele luchtbehandelingskasten. Hieraan voldoet Systemair door de vele combinaties die mogelijk zijn. Hieronder volgt een overzicht van standaarden en de meest voorkomende extra opties. Standaard Warmtewiel of tegenstroomwarmtewisselaar Plug-ventilatoren met EC-motor (voor iedere kastgrootte verkrijgbaar in verschillende maten voor een optimale bedrijfseconomie) Afscherming van ventilatorsecties Geïntegreerde regelsystemen (zie pagina 5) Toevoer- en afvoerfilters, filterkwaliteit F7/F5 Steunpoten met verstelbare poo tjes, luchtbehandelingskast voor binnenopstelling. Extra opties Toevoerklep en afsluiter met servomotor; aan/uit of veerteruggang Koelunit; DV Cooler volledig aangesloten en gemonteerd, traploos regelbaar Warmwaterbatterij Elektrische verwarmer Koelbatterij; koud water of DX Change-over batterij Sectie met geluiddempers met standaard coulissen en speciale uitvoeringen die droog of nat kunnen worden gereinigd Kleppen met servomotor Dak, bitumen membraan, versterkt met sterk polyester bitumen materiaal Dak, trapezium dakplaten, alu-zink staalprofielen Basisframe, voor dakunits en units voor binnenopstelling in sterke gegalvaniseerde staalprofielen met hijsogen Filter, kwaliteit F5/F7.

Luchtbehandelingskasten TIME EC en DV 7 Regelsysteem De regelsystemen van de TIME EC-luchtbehandelingskasten zijn af fabriek gemonteerd en getest. Met dit gebruiksvriendelijk systeem worden de functies en parameters via het externe bedieningspaneel geselecteerd. Het bedieningspaneel kan overal worden geplaatst en kan worden gebruikt als afstandsbediening. De belangrijkste bedrijfsgegevens worden continu op het display van het bedieningspaneel getoond, waaronder alarmmeldingen, bedrijfswaarden, bedrijfsstatus en tijdinstellingen. Opstarten is eenvoudig, aangezien het regelsysteem al is ingesteld met standaardtemperaturen, tijdinstellingen en regelsequenties. De standaardinstellingen kunnen eenvoudig worden gewijzigd in de gewenste bedrijfswaarden. Standaard Bedieningspaneel Weekschema Keuze uit: Temperatuurregeling: Cascaderegeling ruimtetemperatuur, toevoerluchttemperatuur, voor buitentemperatuur gecompenseerde toevoerluchttemperatuur, buitentemperatuurafhankelijk schakelen tussen ruimteregeling en toevoerluchtregeling Luchtregeling: 2 vaste luchtstromen (CAV), constante kanaaldruk (VAV), constante kanaaldruk met afvoerventilator als slave Langer doordraaien Nachtkoeling Terugwinning van koeling Filterbewaking op toevoer- en afvoerfilter Alarmmeldingen en veiligheidsfuncties Modbus. Extra opties Extern brandsignaal of 2 stuks brandthermostaten Verwarmingselement, regeling plus vorstbeveiliging Elektrische verwarmer, modulerend met oververhittingsbeveiliging en regeling Regeling voor koelbatterij Regeling voor DV Cooler Verwarmings- en koelkleppen incl. servomotor Toevoer- en afvoerafsluiters en servomotoren LON of TCP/IP TCP/IP webinterface en toegang via android-toepassing mogelijk.

8 Luchtbehandelingskasten TIME EC en DV Afmetingen + B C A A TIME EC met warmtewiel TTIME EC met tegenstroomwarmtewisselaar TIME EC met warmtewiel TIME EC 10 15 20 25 30 40 A: Lengte 2.090 2.090 2.090 2.090 2.090 2.090 B: Hoogte 970 1.120 1.270 1.420 1.570 1.720 C: Hoogte van voet 100 100 100 100 100 100 Breedte 970 1.120 1.270 1.420 1.570 1.720 Gewicht 440 460 590 665 730 970 TIME EC met tegenstroomwarmtewisselaar TIME EC 10 15 20 25 30 40 A: Lengte 3.210 3.360 3.510 3.510 3.810 3.810 B: Hoogte 970 1.120 1.270 1.420 1.570 1.720 C: Hoogte van voet 100 100 100 100 100 100 Breedte 970 1.120 1.270 1.420 1.570 1.720 Gewicht 542 634 782 864 1.131 1.248 De hierboven genoemde afmetingen en gewichten zijn gebaseerd op warmtewiel plus waterbatterij. De afmetingen en gewichten van andere combinaties moeten worden berekend in SystemairCAD. Geleverd in 2 secties. Let op: toevoer- en afvoerafsluiters en warmwaterbatterijen zijn extra opties. De hierboven genoemde afmetingen en gewichten zijn gebaseerd op tegenstroomwarmtewisselaar plus waterbatterij. De afmetingen en gewichten van andere combinaties moeten worden berekend in SystemairCAD. Geleverd in 3 secties. Let op: toevoer- en afvoerafsluiters en warmwaterbatterijen zijn extra opties.

Luchtbehandelingskasten TIME EC en DV 9 Documentatie Orderspecifieke technische documentatie, opgesteld in SystemairCAD. Air handling unit design SystemairCAD Version C2014-05.05.D5 11-09-2014 Summary for unit no. 1 2 Danvent DV TIME 25 3 4 Plan view Access side 5 Right end Technical specification Left end Damper Unit Pressure drop 2 Pa Motor Damper blades Standard Motor 250 type500 EC motor Frequency band [Hz] 63 125 1K 2K 4K 8K Total Bulkhead light with external switch 1 pcs [db] Motor [db] size[db] [db] ZID.GG.CR Sound power level [db] [db] [db] [db] [db(a)] Motor 76 protection 74 Built-in Supply air 71 75 72 67 64 59 77 Outdoor air 67 68 54 49 43 36 64 Rated 69 power 63 2.00 kw Exhaust air 72 76 Speed 76 (nominal) 74 74 69 66 62 78 1880 RPM Filter Current, 69 Amp. 62 2.60 A Extract air 67 68 54 48 43 36 63 Sound break 65 Dimensioning 65 pressure Consumed 55 drop 47 power from 41mains power 38 supply, 35 including 31 speed control 52 129 1.28 kw Pa out pressure drop/final Bulkhead pressure light with drop external switch 70/188 1 pcs Initial Pa Velocity, face area 1.98 m/s Control system Velocity, filter area Heating coil, Fluid 0.11 m/s system Language - based in controller on Filter the Systemair class menu F7 Dansk TIME air handling units are built with a complete and fully integrated control Air flow 5000 m³/h E28 controller. Control panel Filter delivered size Yes 2x[592x592] Pressure drop 23 Pa External Modbus integrated communication Filter length 535 15.3/22.0 mm Air temperature before/after C Air/fan data Supply Extract Temperature control Bulkhead light with Outdoor external temperature switch compensated supply air 1 pcs Air relative humidity before/after 29/19 % Airflow (1.205 kg/m³) 5000 5000 m³/h control Capacity 11.18 kw Face velocity (unit) 1.65 1.65 m/s Doors and panels dimensions Fan control Constant duct pressure Rotary heat exchanger Face velocity 2.00 m/s External pressure 250 250 Pa Transmitter type delivered #not defined Fluid type Water Supply Extract Fan speed 1599 1543 RPM Temperature compensated air flow #not defined 5000 Fluid temperature inlet/outlet 60.0/30.0 m³/h C Air flow 5000 Motor 2.00 2.00 kw Sensors delivered No Fluid flow rate 0.09 l/s Pressure drop 157 157 Pa Voltage 400 400 V Transmitter type No display -12.0/17.3 Fluid before/after pressure drop 0.4 kpa Air temperature 22.0/-3.5 C Rated current 2.60 2.60 A Damper motor supply air Motor ON/OFF 90/29 humidity Fluid before/after velocity 0.14 m/s Air relative 40/97 % Damper motor extract air Motor ON/OFF Capacity Coil volume 58.95 kw 6.1 l External control via digital input Extended running - normal speed Temperature efficiency Connection side 86.2 Service % side Unit data Free cooling Free cooling without external sensors size inlet/outlet 42.8 Humidity efficiency Connection 1 1/4" %/ 1 1/4" Unit width 1420 mm Coil configuration Heating exchanger Tube type material Cu Heat Temperature exchanger Weight 722 kg Frost protection heating Standard frost protection (Wave Fin height) material Al Efficiency D14 - High Power supply 3x400V + N + PE 50 Hz Valve for heating 2-Way valve, Kvs 1.00, DN15 Inside thread Fin spacing 2.1 mm Rotor drive Variable speed Filter Supply air F7 - Extract air M5Pressure drop 11 kpa Electrical 1x230V, 40W, 0.7Amp No. of rows 2 data ext.fire signal Heat recovery 86.2 % Fire guards Preconfigured for DVH-25-W-Z-2-9-600-1160-2.1-CU-Al-H-1 sector Coil code 1 pcs 1/4 Purging SFPv, clean filters including speed control 1.59 kw/(m³/s) Lamps and switch for lamps Yes Bulkhead light with external switch 1 pcs Heating Air 11.2 kw - 15.3/22.0 C Motor size 2 x 2.00 kw Sound power level Total Systemair A/S Ved Milepælen 7 8361 Hasselager Afmetingen Technische specificaties regelsysteem Toevoerunit onderdelenspecificatie Water 60/30 C - 0.4 kpa - 0.09 l/s Mains - The 1 1/4" power extract / 1 supply 1/4" unit Pipe for consist connections control system of Fan, Plug Switch board data Voltage 3x400V + N + PE 50 Hz Empty section Max lk Air flow 5000 m³/h 16 ka Supply air Outdoor air Exhaust air Extract air Sound Pressure break drop out 2 Pa pressure Min lk External 250 Pa 650 A db(a) Length 52 150 mm 77 db(a) 64 db(a) 78 db(a) 63 db(a) Pressure Max drop 16 Pa fuse 25 A Min fuse 10 A Static pressure 577 Pa Extract air 16 A Total pressure 609 Pa fan,fuse Supply air fan, fuse 16 A Fan speed 1599 RPM protection of the mains power The installer must Maximum ensure that fan speed supply relating to 1880 RPM Total efficiency Damper frequency converters is according by static to local pressure, statutory incl. requirements. motor and speed By one control or more 400 62.7 % Telephone : +45 87387500 Telefax : +45 87387501 Pressure by be total installed. pressure, drop 2 Pa VAC motors, HPFI Total type efficiency B must incl. motor and speed control 66.2 % Damper kg/m³) blades Standard K-factor (p=1.2 197 www.systemair.dk mail@systemair.dk Bulkhead light with external switch 1 pcs Fan type - Large GR45C-ZID.GG.CR The supply unit consist of Direct drive 6 Afvoerunit onderdelenspecificatie 7 22-08-2014 Produktvalgsprogram SystemairCAD Version C2014-05.05.D5 Danvent DV TIME 25 8 Projekt: Filter Dimensioning pressure drop 91 Pa 22-08-2014 Produktvalgsprogram SystemairCAD Version C2014-05.05.D5 Danvent DV TIME 25 11 Initial pressure Tilluft drop/final Projekt: pressure drop 1350x600 mm 45/137 Pa Velocity, face Fraluft area 22-08-2014 Produktvalgsprogram 1350x600 SystemairCAD mm Version C2014-05.05.D5 1.98 m/s Danvent DV TIME 25 12 Projekt: Velocity, filter Afkast area 22-08-2014 Produktvalgsprogram 1350x600 mm SystemairCAD 0.17Version m/s C2014-05.05.D5 Danvent DV TIME 25 13 Filter class Projekt: M5 Filter size Adgangsrettigheder - kodeord 2x[592x592] Afsnit om forsendelse Filter length 535 mm Der er 3 forskellige Indkapsling sikkerhedsniveauer indbygget i sektion med fraluftventilator på TIME Bulkhead light with external switch 1 pcs Operatør niveau (intet kodeord) - adgang til at aflæse værdier og til at ændre brugerrelevante værdier vedrørende Indkapslingen Spjæld er integreret - fraluft i anlægget eller afkast i henhold til det til fri, den on/off tekniske motor dokumentation. Indkapslingen er placeret bag Produkt Dimensioner tidsprogram, temperatur, inspektionsdør/afskærmning (Bredde x højde luftydelse x længde), og annullering til fraluftventilatoren. Vægt, alarm inklusiv med Indkapslingens emballage genstart af anlægget, navn Aggregatets hvis man er indkapsling vægt har fjernet årsagen til nr. 2. Ingen eksterne el-komponenter er alarmen Rotary heat inklusiv exchanger emballage direkte forbundet Spjældet til denne åbnes indkapsling. og lukkes LON af en bus on/off - hvis spjældmotor leveret - skal - 20 tilsluttes Nm - driftstid regulatoren 150 sekunder. til denne indkapsling. Alle CST-25-R-4-1120-Std-2 1520 Service x 1520 niveau komponenter x 1250 (kodeord) mm i denne - adgang sektion til at ændre er forbundet 409 fundamentale kgmed kabler værdier, direkte adgang til indkapslingen. til 408 at gemme kg Der ændrede er monteret værdier, kabelstrips adgang for til at let føring af Data are stated genstarte on supply. anlæg kabler på fra grundlag indkapslingen Forberedt af egne i for denne gemte eksternt sektion værdier brandsignal og eller til indkapslingen fabriksindstilling CST-25-R-3-970-Std-2 1520 x 1520 x 1100 mm 314 kg placeret ved 314 tilluftventilatoren. kg Når aggregatet er samlet på System niveau, pladsen som skal er det alle Aggregatet højeste kabelgennemføringshuller niveau er forberedt (hemmeligt for et eksternt kodeord) tætnes. brandsignal. - ubegrænset Får adgang aggregatet til at et ændre brandsignal, alle værdier lukker samt det til ned. at Fødder Har aggregatet været lukket ændre opsætningen leveres monteret af hele på aggregatsektionerne Fan, Plug ned systemet i tilfælde af brand, skal det genstartes på betjeningspanelet. Dette kan ændres så aggregatet selv starter op, når det Indkapsling indbygget eksterne brandsignal i sektion med forsvinder. tilluftventilator Der er monteret på TIME Air flow 2 klemmer i indkapslingen til det eksterne brandsignal. Alarm og sikkerhedsfunktioner 5000 m³/h External pressure Indkapslingen er integreret i anlægget i henhold til den tekniske 250 dokumentation. Pa Indkapslingen er placeret bag Ved alarm blinker inspektionsdør/afskærmning den røde Filtervagt lysdiode på over betjeningspanelet. til posefilter tilluftventilatoren. i Efter Indkapslingens kvittering lyser navn dioden er indkapsling konstant til nr. fejlen 1. Alle er rettet. komponenter Alarmlisten i denne sektion er Pressure drop viser typen på forbundet alarmen direkte samt Filtervagt dato til indkapslingen. og over tidspunkt posefilter for Alle den i tilluft eksterne opståede er tilsluttet el-komponenter alarm. 16 regulatoren, Alarmer skal Pa opdeles som forbindes viser i klasse alarm, til denne A, når B indkapsling eller den mekanisk C: og kablerne indstillede føres grænseværdi til overskrides. Static pressure Alarm type indkapslingen A vil stoppe ventilatorerne inde i sektionen og lukke gennem spjældene et rør i bunden eller ændre af 517 sektionen. driften i Pa henhold Alle kabler til en i sektionen speciel opsætning fra eksterne komponenter, skal på Total pressure pladsen have monteret stikforbindelser i henhold til diagram. Når aggregatet er samlet på pladsen, er det vigtigt at Alarm type B informerer Filtervagt kun brugerne over om posefilter en fejl samtidigt i fraluftmed at anlægget 550 fortsat Pa er i normal drift Fan speed kabelgennemføringen (røret) i bunden bliver tætnet af installatøren, for at undgå indtrængning af falsk luft. Alarm type C informerer Filtervagt kun brugerne over om posefilter at anlægget i fraluft er er blevet tilsluttet stillet 1543 regulatoren, om fra automatisk RPM som viser drift alarm, til manuel når den drift mekanisk indstillede grænseværdi Maximum fan For speed at beskytte Antal vandvarmebatteriet sektioner overskrides. med interne mod frost el-komponenter måles vandtemperaturen - 2 1880 af en føler RPM inde i vandet i et af batteriets returløbsrør. Total efficiency Styrespændingen by static pressure, til ventilen incl. motor holdes and på speed et niveau, control så vandtemperaturen 62.5 altid er over % den fabriksindstillede minimum. Denne TIME aggregat leveret i 2 sektioner. Afhængig af aggregatets opbygning skal kablerne mellem indkapslingerne føres gennem Total efficiency regulering by total er pressure, altid aktiveret incl. Kommunikation - motor både and når anlægget speed til control BMS er i drift, (CTS) og system når anlægget via 66.4 MODBUS er stoppet. % Hvis vandtemperaturen alligevel falder under minimum, sektionen stoppes med ventilatorerne veksler (rotor og eller anlægget modstrøm) lukkes og helt DVU ned. (kølekompressor) sektionen - hvis aggregatet omfatter en DVU sektion. K-factor (p=1.2 kg/m³) Forsyningskablet Regulatoren og kablerne forberedt fra de eksterne til kommunikation komponenter 197 via skal en RS485 forbindes port til med klemmerne MODBUS i indkapsling baserede BMS 1, som systemer er placeret (Building inde i Management Fan type - Alarm Large signal sektionen med systems). tilluftventilatoren. Kablerne GR45C-ZID.GG.CR føres til indkapslingen inde i sektionen gennem et rør i bunden af sektionen. Direct drive Regulatoren kan fungere som et selvstændigt system uden opkobling til andre regulatorer og BMS systemer. Der er monteret Fraluftventilator et relæ med potentialfrit kontaktsæt i indkapslingen. Kontaktsættet er aktiveret i tilfælde af alarm på anlægget. Motor Fri køling (natkøling) Fleksibelt system Aggregatets fraluftsventilator drives af en EC motor med ventilatorhjulet monteret direkte på motorakslen. Alle parametre i Motor type motorens omdrejningsregulering En føler, som måler er udelufttemperaturen blevet tilpasset EC og testet motor inde i på aggregatet fabrikken. før På tilluft grund filteret af EC giver motoren mulighed skal for den styring eksterne af frikøling, så hvis En erfaren servicetekniker elforsyning beskyttes udelufttemperaturen vil være i i henhold stand til til at myndighedskrav efter tilpasse midnat reguleringen er under for ekstra-beskyttelse den yderligere ønskede til brugernes temperatur af frekvensomformere. ønsker; i rummet, og den aktuelle gennemsnitstemperatur i Motor size ZID.GG.CR Reguleringen af luftydelsen fraluften kan ændres fra rummene mellem er 2 over metoder, ønsketemperaturen, som er enten konstant startes ventilatorerne luftydelse gennem om sommeren ventilatorerne for at eller køle rummene i løbet af natten. Motor protection konstant tryk Tilluftventilator i kanalernefunktionen er kun aktiv før og efter de planlagte Built-in drifts tider. Alle parametre kan indstilles individuelt. Når rumtemperaturen er Rated power Metoden for Aggregatets temperaturregulering tilluftventilator nået stoppes kan aggregatet. drives ændres af mellem en Efter EC motor regulering 1 time med vil systemet ventilatorhjulet af 2.00 rumtemperatur starte kwop monteret eller igen, tillufttemperatur hvis direkte rumtemperaturen på motorakslen. samt udetemperatur igen Alle er parametre for høj. Ekstra i rum- og Speed (nominal) kompensering motorens af den omdrejningsregulering valgte udendørs temperatur. temperatur er følere blevet vil tilpasset forøge og nøjagtigheden testet 1880 på fabrikken. af RPM funktionen. På grund af EC motoren skal den eksterne Current, Amp. I tillæg til eller elforsyning som alternativ beskyttes til drift i henhold i henhold til myndighedskrav til tidsprogrammet for kan ekstra-beskyttelse 2.60 aggregatet A også af startes frekvensomformere. og stoppes af eksterne Forlænget drift - normal hastighed Consumed power start/stop from signaler. mains power supply, including speed control 1.15 kw Frostbeskyttelse Via en af trykknap varmebatteri kan aggregatet via temperaturføler aktiveres med i vandet Bulkhead Et light stort with antal external alternative switchfunktioner findes i regulatoren og kan aktiveres. 1normal pcs hastighed i en given tid. Der er monteret klemmer i indkapslingen for For at beskytte tilslutning vandvarmebatteriet af kabel fra det mod eksterne frost måles tryk. vandtemperaturen Systemair leverer af ikke en trykknap føler inde eller i vandet kabel i til et denne af batteriets funktion. returløbsrør. Udetemperatur Styrespændingen kompenseret til tillufttemperatur ventilen holdes så regulering højt, at returtemperaturen, som måles af føleren, altid er over den fabriksindstillede minimumtemperatur. Lamper Denne inde i regulering indendørs aggregater Regulering af tillufttemperaturen er baseret på værdier, altid som aktiveret måles af - 2 både temperaturfølere: når anlægget er i drift, og når anlægget er stoppet. Hvis vandtemperaturen Der er alligevel monteret falder en afbryder under minimumtemperaturen, for tænd og sluk af lamper stoppes uden ventilatorerne, på aggregatet. anlægget Der er monteret lukkes helt stik ned på alle og alarm Other parts En føler, som kabler fra lamper, der aktiveres. måler udelufttemperaturen inde i aggregatet før tilluft filteret ikke er monteret i samme sektion som indkapslingen. Til disse kabler er der lavet føringsveje til indkapslingen. Alle kabler og En føler, som Der skal er klemmer installeres føringsveje for i 230 tilluftkanalen. V er cirkulationspumpe klargjort Føleren for let leveres montage i indkapslingen. med på pladsen. 10 m kabel, Pumpen Afbryderen og vil er altid tilsluttet er køre placeret i klemmerne. Feet or baseframe når udetemperaturen på panelet ved siden er under af inspektionsdøren den til Den ønskede indstillede tillufttemperatur værdi indkapslingen. (+10 indstilles C). Ved på betjeningspanelet. højere udetemperatur Her vælges vil pumpen fast køre, sammenhæng når signalet til mellem varme udetemperatur er over 0 %. Pumpen og har en Feet or baseframe tillufttemperatur indstillelig, ved hjælp korteste af 6 parametersæt. køretid, og vil Det blive kurveafhængige motioneret en gang setpunkt Feet i døgnet for tillufttemperaturen kl. 15.00. Pumpen realiseres er ikke inkluderet ved PI-regulering i leverancen. Height of feet af ydelsen or baseframe veksler, varmebatteri og kølebatteri (hvis der er installeret 100kølebatteri). mm Alle kapaciteter reguleres trinløst. Corrosion protection 2-vejs ventil - varmebatteri Galvanized Z275 Konstant kanaltryk Varmeydelsen reguleres af en 2-vejs ventil med en modulerende ventilmotor. Lufttrykket reguleres Ventil og selvstændigt ventilmotor er for inkluderet tilluft og fraluft. i leveringen. Det ønskede Ventil, lufttryk ventilmotor for tilluft og temperaturføler og fraluft ved både til frostbeskyttelse normal og ved er reduceret ikke monteret og Rigid duct luftydelse connection, indstilles kabler 20 mm på er LS ikke betjeningspanelet profile inkluderet. Vi anbefaler, i Pa. Det aktuelle at ventilen tryk altid måles monteres af tryktransmitter i returrøret i tilluftkanal varmesystemet. og tryktransmitter i Product fraluftkanal. En PI regulering tilpasser Dimensions automatisk (width omdrejningstallene x height) til de ønskede tryk via de 2 frekvensomformere. Eksterne tryktransmittere Spjæld leveres - tilluft, uden on/off kabel. Outdoor 1350x600 motor mm Spjældet åbnes og lukkes af en on/off spjældmotor - 20 Nm - driftstid 150 sekunder. Andere onderdelen Beschrijving van functies SystemairCAD Om de optimale maatvoering van de functies van de luchtbehandelingskast te garanderen, is een geavanceerd ontwerpprogramma ontwikkeld met de naam SystemairCAD. Het programma is bijzonder gebruiksvriendelijk en vormt een eenvoudige en snelle manier om de benodigde functies van de kast te combineren. De software maakt een technische berekening en werkt automatisch complete technische documentatie uit. De documentatie wordt als pdf gepresenteerd en betreft alleen de gekozen luchtbehandelingskast. Ook zijn tekeningen van de specifieke combinatie in het rapport opgenomen. De tekeningen kunnen in 2- of 3D naar een CAD-systeem worden overgezet via DXF-bestanden of Revit. Systeemoplossingen Systemair biedt complete systeemoplossingen op het gebied van brandwerende ventilatie, centrale woningventilatie, VAV en schoolventilatie. Kijk voor meer informatie over de systeemoplossingen op systemair.nl. Neem contact op met Systemair voor technische documentatie, een offerte of een order of download SystemairCAD op www.systemair.nl. SystemairCAD vereenvoudigt het vergelijken van verschillende opties.

Systemair B.V. Van Leeuwenhoekstraat 2 3846 CB Harderwijk Postbus 263, 3840 AG Harderwijk Tel. +31 (0) 341-439100 Fax +31 (0) 341-439190 info@systemair.nl www.systemair.nl Systemair <maand> <jaar> <versie/code>