SecuriFire 2000 & SecuriFire Product presentation.

Relaterede dokumenter
Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

WIO200A INSTALLATIONS MANUAL Rev Dato:

Maskindirektivet og Remote Access. Arbejdstilsynet Dau konference 2015 Arbejdsmiljøfagligt Center Erik Lund Lauridsen

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications

Lithium-Ion Jump-Starters / Jumper Cables

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

Beovox 5000 versions. Classic Audio Technical Information

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001

WI180C-PB. Online-datablad

MS-H280-Pro Magnetic Stirrer

UNISONIC TECHNOLOGIES CO.,

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1

TDC 4 Indoor voltage transformers

MOC On-Demand Administering System Center Configuration Manager [ ]

WIO200A Water in oil sensor

Valg af Automationsplatform

Lovkrav vs. udvikling af sundhedsapps

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Green Passenger Ferries

Spare parts ASC 5300 G V5

CONNECTING PEOPLE AUTOMATION & IT

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.

Spare parts ASC 3500 G V7 SKU:

GIGABIT COLOR IP PHONE

Small Autonomous Devices in civil Engineering. Uses and requirements. By Peter H. Møller Rambøll

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

CONNECTING PEOPLE AUTOMATION & IT

Spare parts ASC 3000 G V11 SKU:

Spare parts ASC 3500 G LE V6 SKU:

Unitel EDI MT940 June Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc.

3D NASAL VISTA 2.0

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

Delta Elektronik A/S - AKD

Varenr.: højre venstre º højre med coating º venstre med coating

En god Facebook historie Uddannelser og valgfag målrettet datacenterindustrien!?

SHARKY 775 KOMPAKT ENERGIMÅLER ULTRALYD

ECE 551: Digital System * Design & Synthesis Lecture Set 5

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

BioLite NET Innovative Fingerprint Terminal

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

Proportional pressure regulators VEAA

CART MULTITEK CART MULTITEK CART. The MultiTek Cart

SYNOLOGY DS418j 4-bay NAS server

Vore IIoT fokus områder

Screened electronic cable LiYCY

HP LaserJet Pro M102w Laser

ELECTRONIC CONTROL BOX

Statistical information form the Danish EPC database - use for the building stock model in Denmark

Skidding System. Challenge Us

OVERVIEW MARINE HYBRID ÜBERSICHT SCHEMA MARINE HYBRID

Programmable pressure transmitters PTM

Dell Latitude 14" I5-8250U 8GB 256GB Intel UHD Graphics 620 Windows 10 Pro 64-bit

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Strategic Business Area. LINAK og vores rejse ind i AUTOMOTIVE krav og regulativer

Vejledning til at tjekke om du har sat manuel IP på din computer.

BACK-END OG DATA: ADMINISTRATION HVAD ER DE NYE MULIGHEDER MED VERSION 7.1? STEFFEN BILLE RANNES, 4. FEBRUAR 2015

EN 54-13: 2005 Fire detection and fire alarm systems Part 13: Compatibility assessment of system components.

Fundamentals of HVAC Control Systems

3D NASAL VISTA TEMPORAL

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Plug Connectors for Food & Beverage

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav

Hudevad P200. Technical datasheet

Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt

SB ShooeBox. SB Introduction / Indledning SB Inspiration combinations/inspirationsopstillinger SB Functionality/Funktion 07-07

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

Kignæs hallen. Date: Operator: Projektafdelingen / DANE

Switchmode rectifier. Type LEIF with PFC. »We store the world's energy« Network

Diamond Core Drilling

Slot diffusers. Slot diffusers LD-17, LD-18

Tekniske data. håndtere 128 spjæld med individuelle statusindikationer. Brandspjældene kan

laser sensors diffuse reflection sensors 2200 analog signal 4 to 20mA / 0 to 10V 5 external teachable measuring ranges

MultiProgrammer Manual

Komplet køreklar 6000 W Solcelle anlæg. Kr ,- inkl. moms

DATASHEET PA8506-V. Section. Voice Evacuation. Category. PA8506-V System. Code PA8506-V. Certificate EN 54-16: 2008 n.

Komplet køreklar 3000 W Solcelle anlæg. Kr ,- inkl. moms

OG-3600 Series Fiber Optic Transport for opengear card frame platform w/ SNMP Management

Flight Medical Innovations Ltd Product Catalogue. LIT-0139 A Product Catalogue

Epson AcuLaser CX37DNF Laser

DET KONGELIGE BIBLIOTEK NATIONALBIBLIOTEK OG KØBENHAVNS UNIVERSITETS- BIBLIOTEK. Index

Status på det trådløse netværk

PARALLELIZATION OF ATTILA SIMULATOR WITH OPENMP MIGUEL ÁNGEL MARTÍNEZ DEL AMOR MINIPROJECT OF TDT24 NTNU

MOC On-Demand Identity with Windows Server 2016 [20742]

Lancering af Exchange Server November 2009

INIM Previdia-Compact Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

Vi gør opmærksom på at undervisningen kan foregå på engelsk, afhængig af instruktør og deltagere. Alt kursusmateriale er på engelsk.

EuroForm OCR-B Installation Guide

#MADE IN DENMARK# Danish Design by Hammel

,

talk outline sea bed network deployment issues; energy distribution seabed network issues;

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17

QUICK MANUAL BRUGERNAVN: ADMIN PASSWORD: APP: SMARTEYES PRO PORT: SecVision - Quick Manual v1.0

Digital Quick Setup Guide

Maneurop reciprocating compressors

MMS Multi Media Storage

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

Transkript:

SecuriFire 2000 & SecuriFire 1000. Product presentation.

General. Compact system Can be networked SecuriLine extended (2 loops) For controlling single zone extinguishing systems State-of-the-art Multi-Layer Technology (Microvia) Clear stress-free indication and operation Multilingual Can be configured simply and in a structured manner by PC software Approved and certified 03/03/2011 / Nr. 2 / SCW Securiton AG

Overview SecuriFire 2000 & 1000 SecuriFire 2000 2 loops with 4 loops optionally 2 monitored outputs for alarm transmission systems & alarm systems 5 relay outputs MMI-BUS & fire brigade panel interface Can be networked B6-SCP2010 B6-SCP2020 B6-SCP2030 with full door with operating panel with operating panel and printer B6-SCP2040 with operating panel, printer and cut-out SecuriFire 1000 1 loop 2 monitored outputs for alarm transmission systems & alarm systems 5 relay outputs MMI-BUS & fire brigade panel interface B6-SCP1020 with operating panel B6-SCP1030 with operating panel and printer 03/03/2011 / Nr. 3 / SCW Securiton AG

SecuriFire 2000 2 loop control unit with optional expansion to 4 loops Can be networked as a 2 loop version Device bus for connecting remote operating panels, fire brigade control panels and floor plan panels Interfaces for transmission and alarm systems, relay outputs, monitored inputs and outputs Simple to operate configuration and commissioning tools Event memory for 65,000 messages in real time Remote system access over TCP/IP Can be connected to superordinated computer systems or fire detection management systems over serial data interfaces Comprehensive, integrated overvoltage protection concept 03/03/2011 / Nr. 4 / SCW Securiton AG

SecuriFire 2000 Topology B4-USI* B4-DAI2* Alarm notification & transmission equipment B4-EIO* B6-NETx * MMI-BUS * modules can be used emotionally 03/03/2011 / Nr. 5 / SCW Securiton AG

SecuriFire 1000 1 loop control unit Device bus for connecting remote operating panels, fire brigade control panels and floor plan panels Interfaces for transmission and alarm systems, relay outputs, monitored inputs and outputs Simple to operate configuration and commissioning tools Event memory for 65,000 messages in real time Comprehensive, integrated overvoltage protection concept 03/03/2011 / Nr. 6 / SCW Securiton AG

SecuriFire 1000 Topology Alarm notification & transmission equipment MMI-BUS 03/03/2011 / Nr. 7 / SCW Securiton AG

Extinguishing panel SecuriFire 2000 Automatic electronic control and delay unit for controlling an extinguishing zone can also used as a combined fire alarm and extinguishing system control unit or as a control unit Simple to operate configuration and commissioning tools External device bus for connecting remote operating panels, fire brigade control panels and floor plan panels Event memory for 65,000 messages in real time Comprehensive, integrated overvoltage protection concept 03/03/2011 / Nr. 8 / SCW Securiton AG

Extinguishing panel SecuriFire 2000 Topology 03/03/2011 / Nr. 9 / SCW Securiton AG

Double security thanks to software redundancy in the event of unforeseen software errors occurring, an ordered emergency operating mode is automatically started In emergency operating mode, only the part of the operating program that is absolutely necessary is loaded during start up This does mean that the range of functions and operations is restricted as a consequence, but on the other hand ensures that the system continues to function properly with regard to alarms and alarm forwarding Depending on the national installation guidelines, the SecuriFire is also suitable for monitoring areas of more than 3000 m² The type and scope of emergency operation can be configured 03/03/2011 / Nr. 10 / SCW Securiton AG

Operating Panel MIC 711 5.7 TFT-colour display Functional keys and scroll wheel No text, only symbols on the operation panel 4 different languages online changeable Can also be operated as a networking operating panel within a SecuriLan Interface for printer EPI-Bus (extension bus) to connect up to 3 different modules (optional) Unified operational concept between SecuriFire and SecuriSafe 03/03/2011 / Nr. 11 / SCW Securiton AG

Multilingual user interface TFT Colour display Functional keys Numeric keys Zoom key Collective LED indications Menue list Selection key Back key Multiple selection key SecuriWheel rotating menue wheel 03/03/2011 / Nr. 12 / SCW Securiton AG

Mechanical construction SecuriFire 2000/1000 Back Panel Main processor unit & power supply Module cover & rechargeable cells Cabinet with operating panel and log printer Case dimensions: 445 x 400 x 140 mm 03/03/2011 / Nr. 13 / SCW Securiton AG

SecuriFire 2000 connection technology Clear construction Only uses plug and socket connections No direct wiring on modules Modules are simple to change or extend Increased EMC protection for modules with a front plate Power supply unit with 5 outputs for external devices 03/03/2011 / Nr. 14 / SCW Securiton AG

EMC and Overvoltage protection As a result of the comprehensive integrated overvoltage protection concept pursuant to EN50130-4 (EMC) and EN 50082-2 additional measures, e.g. spike suppressors etc., are no longer necessary. Fully enclosed electronics Modules with sheet metal cover Earthed metal case Back wall with cable inlet and strain relief Overvoltage protection with broadband decoupling of the supply voltage, network filter and protective diodes Shielded cables Connection for antistatic set 03/03/2011 / Nr. 15 / SCW Securiton AG

SecuriFire 2000 extra modules. The following modules can be fitted as necessary to the main processor unit of the SecuriFire 2000: B4-DAI2 Loop circuits 2 loop circuits or 4 stub lines B4-EIO Inputs/Outputs 8 primary outputs, monitored for short circuits, wire breaks and overloads - 10 HX130 detector zones - primary inputs or - VdS conformant extinguishing interfaces B4-USI Universal Interfaces 1 x RS485 1 x RS232/RS485 1 x PCM CIA modem B6-NET2 485 Network module Transmission type: TCP/IP Direction: bidirectional, fullduplex 1 x Ethernet 100 Base TX LAN interface 100 Mbit/s 2 x RS485 interfaces 2.5 Mbit/s with redundant cabling B6-LAN Network module Transmission type: TCP/IP Direction: bidirectional, fullduplex 2 x Ethernet 100 Base TX LAN interface 100 Mbit/s 03/03/2011 / Nr. 16 / SCW Securiton AG

Thank you for your attention! Securiton AG Alarm and Security Systems Alpenstrasse 20, CH-3052 Zollikofen www.securiton.com, info@securiton.com 03/03/2011 / Nr. 17 / SCW Securiton AG