Proportional pressure regulators VEAA

Størrelse: px
Starte visningen fra side:

Download "Proportional pressure regulators VEAA"

Transkript

1

2 Key features Innovative Versatile Reliable Easy to install Silent operation Very low power consumption High precision Integrated piezo technology In-line valves Sub-base valves Simple electrical and pneumatic interfaces Choice of different setpoint specifications Current input Voltage input Integrated pressure sensor with separate output Diagnostics: Operating voltage: over- and undervoltage Setpoint value: falling below and exceeding Consistent pressure regulation performance with long-term stability Mounting the in-line valve via three lateral through-holes H-rail mounting Attaching the in-line valve to the mounting plate Mounting the sub-base valve using the sub-base 2 Internet: Subject to change 2018/07

3 Key features In-line valve Power LED (green), fault LED (red) 2 Electrical connection, plug M8 3 Port 2, working air 4 Port 1, compressed air 5 Port 3, exhaust air 6 Through-holes for mounting the valve Sub-base valve Power LED (green), fault LED (red) 2 Electrical connection, plug M8 3 Through-holes for mounting the valve on the sub-base 4 Port 2, working air 5 Port 3, exhaust air 6 Port 1, compressed air 2018/07 Subject to change Internet: 3

4 Key features Mounting the valve manifold H-rail mounting The H-rail mounting 1 can be used to mount the manifold rail 2 on H-rails in accordance with EN To do this, the manifold rail with the H-rail mounting attached is mounted on the H-rail 3 and latched in place. 3 Wall mounting Through-holes for wall mounting are located on the manifold rail. 4 Internet: Subject to change 2018/07

5 Product range overview Version Valve function Pneumatic Pressure regulation Setpoint value input connection 1, 2, 3 range Voltage type Current type [bar] 0 10 V 4 20 ma Pressure regulator In-line valve 3/3-way valve, normally closed QS Sub-base valve 3/3-way valve, normally closed Flange /07 Subject to change Internet: 5

6 Peripherals overview Manifold assembly VEAA Accessories Description 1 H-rail NRH For control cabinet installation 18 2 H-rail mounting VAME For assembly of the H-rail 18 3 Manifold rail VABM-P6-15M Connection direction at side, for control cabinet installation 17 4 Manifold rail VABM-P6-15MB Connection direction underneath, for wall mounting and control cabinet installation 17 5 Cover plate VABB 17 6 Proportional pressure regulator VEAA 17 7 Connecting cable NEBU 18 Page/Internet 6 Internet: Subject to change 2018/07

7 Type codes VEAA 3 1 R1 Type code VEAA Proportional pressure regulator Valve type L B In-line valve Sub-base valve Valve function 3 3/3-way valve, normally closed Pressure range D2 D9 D bar 0 6 bar 0 10 bar Pneumatic connection F Q4 Flange/sub-base Push-in connector 4 mm Setpoint input V1 A4 Voltage variant 0 10 V Current variant 4 20 ma Operating voltage 1 24 V DC Electrical connection R1 Plug M8, 4 pin 2018/07 Subject to change Internet: 7

8 Technical data -M- Flow rate 7 13 l/min -P- Voltage 24 V DC -L- Pressure regulation range bar bar bar General technical data Type code VEAA-L VEAA-B Valve type In-line valve Sub-base valve Valve function 3-way proportional pressure regulator Dimensions W x L x H [mm] 15 x 54.5 x x 61 x 66 Standard nominal flow rate Page 10 Pneumatic connection 1, 2, 3 QS-4 Flange Sealing principle Soft Actuation type Electrical with piezo element Display type LED Type of control Directly controlled Type of reset Mechanical spring Type of mounting Via through-hole, via accessories Mounting position Any Product weight [g] 55 Electrical data Electrical connection Plug M8x1, 4-pin, to EN Nominal operating voltage [V DC] 24 Operating voltage range [V DC] Residual ripple [%] 10 Max. electrical power consumption [W] 1 Setpoint input signal Voltage [V DC] 0 10 Current [ma] 4 20 Accuracy of analogue output [%] 2 Short circuit protection For all electrical connections Reverse polarity protection For all electrical connections Degree of protection IP65 -H- Note Safety position, VEAA: If the electrical power supply fails, the outlet pressure is maintained unregulated and may rise or fall valve blocked. 8 Internet: Subject to change 2018/07

9 Technical data Operating and environmental conditions Operating medium Compressed air to ISO :2010 [7:4:4] Inert gases Note on operating/pilot medium Lubricated operation not possible Inlet pressure at port 1 1) [bar] 0 11 FS (full scale) hysteresis [%] 0.25 FS (full scale) linearity error [%] ± 0.5 FS (full scale) repetition accuracy [%] ± 0.4 FS (full scale) absolute accuracy [%] Max. 0.7 Temperature coefficient [%/K] 0.05 Ambient temperature [ C] 0 50 Temperature of medium [ C] 5 50 Storage temperature [ C] Corrosion resistance class CRC 2) 2 CE marking (see declaration of conformity) To EU EMC Directive Certification RCM compliance mark * 1) Inlet pressure 1 should always be 1 bar higher than the maximum regulated outlet pressure. 2) Corrosion resistance class CRC 2 to Festo standard FN Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications. Materials Seals Housing Note on materials NBR PA-reinforced RoHS-compliant Pin allocation, electrical connection Pin Function V DC supply voltage 2 + Setpoint value 3 GND 4 + Actual value Function An integrated pressure sensor records the pressure at the working port and compares this value with the setpoint value. The pressure is automatically readjusted in the event of deviations. 2018/07 Subject to change Internet: 9

10 Technical data VEAA- -D2-, pressure regulation range Flow rate qn from 12 as a function of outlet pressure p2 Flow rate qn from 23 as a function of outlet pressure p2 10 Internet: Subject to change 2018/07

11 Technical data VEAA- -D9-, pressure regulation range Flow rate qn from 12 as a function of outlet pressure p2 Flow rate qn from 23 as a function of outlet pressure p2 2018/07 Subject to change Internet: 11

12 Technical data VEAA- -D11-, pressure regulation range Flow rate qn from 12 as a function of outlet pressure p2 Flow rate qn from 23 as a function of outlet pressure p2 12 Internet: Subject to change 2018/07

13 Technical data Dimensions In-line valve Download CAD data 1 Plug M8x1, 4-pin Type code B1 B2 D1 D2 H1 H2 H3 H4 H5 H6 H7 VEAA-L Type code L1 L2 L3 L4 L5 VEAA-L /07 Subject to change Internet: 13

14 Technical data Dimensions Sub-base valve Download CAD data 1 Port 1, compressed air 2 Port 2, working air 3 Port 3, exhaust air 4 Plug M8x1, 4-pin Type code B1 B3 D3 H1 H2 H8 VEAA-B Type code L1 L2 L3 L6 L7 L8 L9 L10 VEAA-B Internet: Subject to change 2018/07

15 Technical data Dimensions Download CAD data Connection direction at side Type code B1 B2 B3 D1 D2 D5 D6 D7 D8 D9 H1 H2 H3 H4 H5 H9 VABM-P6-15M-G18-M G1/ M3 M5 2.9 M VABM-P6-15M-G18-M5-6 VABM-P6-15M-G18-M5-8 Type code L1 L2 L3 L4 L5 L6 L7 L8 L10 L11 T1 T2 T4 T5 T6 VABM-P6-15M-G18-M VABM-P6-15M-G18-M VABM-P6-15M-G18-M /07 Subject to change Internet: 15

16 Technical data Dimensions Download CAD data Connection direction underneath Type code B1 B2 B3 D1 D2 D3 D4 D5 D6 D7 H1 H2 H3 H4 H5 H6 VABM-P6-15MB-G18-M G1/8 6 G1/8 M5 4.5 M VABM-P6-15MB-G18-M5-6 VABM-P6-15MB-G18-M5-8 Type code H7 H8 L1 L2 L3 L4 L5 L6 L7 L8 L9 T1 T2 T3 VABM-P6-15MB-G18-M VABM-P6-15MB-G18-M VABM-P6-15MB-G18-M Internet: Subject to change 2018/07

17 Accessories Ordering data In-line valve Pressure regulation range Part No. Type code [bar] Voltage type, 0 10 V VEAA-L-3-D11-Q4-V1-1R VEAA-L-3-D2-Q4-V1-1R VEAA-L-3-D9-Q4-V1-1R1 Current type, 4 20 ma VEAA-L-3-D11-Q4-A4-1R VEAA-L-3-D2-Q4-A4-1R VEAA-L-3-D9-Q4-A4-1R1 Sub-base valve Voltage type, 0 10 V VEAA-B-3-D11-F-V1-1R VEAA-B-3-D2-F-V1-1R VEAA-B-3-D9-F-V1-1R1 Current type, 4 20 ma VEAA-B-3-D11-F-A4-1R VEAA-B-3-D2-F-A4-1R VEAA-B-3-D9-F-A4-1R1 Manifold rail Connection direction at side 4 valve positions VABM-P6-15M-G18-M5-4 6 valve positions VABM-P6-15M-G18-M5-6 8 valve positions VABM-P6-15M-G18-M5-8 Connection direction underneath 4 valve positions VABM-P6-15MB-G18-M5-4 6 valve positions VABM-P6-15MB-G18-M5-6 8 valve positions VABM-P6-15MB-G18-M5-8 Cover plate Including screws (2) and O-rings (3, preassembled) VABB-P6-M 2018/07 Subject to change Internet: 17

18 Accessories Ordering data Description Part No. Type code Connecting cable Straight socket, M8x1, 4-pin Open end, 4-wire Angled socket, M8x1, 4-pin Open end, 4-wire Straight socket, M8x1, 4-pin Straight plug, M8x1, 4-pin Technical data Internet: nebu 2.5 m NEBU-M8G4-K-2.5-LE4 5 m NEBU-M8G4-K-5-LE4 2.5 m NEBU-M8W4-K-2.5-LE4 5 m NEBU-M8W4-K-5-LE4 2.5 m NEBU-M8G4-K-2.5-M8G4 H-rail To EN 60715, 35 x 7.5 (WxH), for control cabinet installation NRH H-rail mounting For H-rail NRH VAME-P7-T Mounting plate For in-line valve VAME-P6-Y 18 Internet: Subject to change 2018/07

Proportional pressure regulators VEAB

Proportional pressure regulators VEAB Proportional pressure regulators VEAB Key features Innovative Versatile Reliable Easy to install Silent operation Very low power consumption High precision Short switching times Piezo technology In-line

Læs mere

UNISONIC TECHNOLOGIES CO.,

UNISONIC TECHNOLOGIES CO., UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output

Læs mere

TDC 4 Indoor voltage transformers

TDC 4 Indoor voltage transformers Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,

Læs mere

KNIFE GATE VALVE FAF 6500

KNIFE GATE VALVE FAF 6500 PRODUCTION STANDARTS DN50 DN600 PN 10 Connection EN 1092-2 / ISO 7005-2 Face to Face EN 558 Series Marking EN 19 Tests EN 12266-1 Corrosion Protection Electrostatic Powder Epoxy Features y Uni-directional

Læs mere

WIO200A INSTALLATIONS MANUAL Rev Dato:

WIO200A INSTALLATIONS MANUAL Rev Dato: WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of

Læs mere

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package High Speed LDO Regulators, High PSRR, Low noise, Series General Description The series are highly accurate, low noise, CMOS LDO Voltage Regulators. Offering low output noise, high ripple rejection ratio,

Læs mere

Hudevad P200. Technical datasheet

Hudevad P200. Technical datasheet Technical datasheet Key benefits Low, streamlined design Ideal in front of glazing to prevent cold draughts Available in two depths For high flexibility in usage Historical Kundenedfald Grøn energi Flat

Læs mere

MS-H280-Pro Magnetic Stirrer

MS-H280-Pro Magnetic Stirrer MS-H280-Pro Magnetic Stirrer www..com Copyright: No part of this manual may be reproduced or transmitted without prior written permission of. VERSION201407 CONTENTS Chapter 1: Working Principle... 3 1

Læs mere

Modulerende kuglehane

Modulerende kuglehane 690 Modulerende kuglehane Cim 690 Modulerende kugleventil Cim 690 kuglehane er en modulerende ventil på grund af venturi boring som gør det muligt at op linear eller logaritmisk flow. Cim 690 kuglehaner

Læs mere

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation PEMS RDE Workshop AVL M.O.V.E Integrative Mobile Vehicle Evaluation NEW - M.O.V.E Mobile Testing Platform Key Requirements for Measuring Systems Robustness Shock / vibrations Change of environment Compact

Læs mere

Metal Oxide Varistor:TVM-B Series

Metal Oxide Varistor:TVM-B Series Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction

Læs mere

Slot diffusers. Slot diffusers LD-17, LD-18

Slot diffusers. Slot diffusers LD-17, LD-18 LD-17, LD-18 Application LD-17 and LD-18 are designed for supply of cold or warm air in rooms with a height between. m and 4 m. They allow easy setting of air deflectors for different modes of operation

Læs mere

Uni-Valve A /S SCOTCH-YOKE. Pneumatisk aktuator - Pneumatic actuator. Type UNI-PD - Type UNI-PS (UNI-PD/PS 50, 70, 85, 100, 125, 150, 200)

Uni-Valve A /S SCOTCH-YOKE. Pneumatisk aktuator - Pneumatic actuator. Type UNI-PD - Type UNI-PS (UNI-PD/PS 50, 70, 85, 100, 125, 150, 200) UniValve A /S V E N T I L E R & I N S T R U M E N T E R Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.univalve.com Pneumatisk aktuator Pneumatic actuator SCOTCHYOKE Type UNIPD

Læs mere

Lithium-Ion Jump-Starters / Jumper Cables

Lithium-Ion Jump-Starters / Jumper Cables AUTOMOTIVE Lithium-Ion Jump-Starters / Jumper Cables Lithium-Ion Jump-Starter 1300: Part No. DRLJS130 1300 4 6 8 cylinder (6 liter gas 3 liter diesel) SafeJump technology prevents sparking and protects

Læs mere

Flight Medical Innovations Ltd Product Catalogue. LIT-0139 A Product Catalogue

Flight Medical Innovations Ltd Product Catalogue. LIT-0139 A Product Catalogue Flight Medical Innovations Ltd. 2019 Product Catalogue Flight 60 Ventilator Piston Single Limb Ventilator (SL) V60-1012 Flight 60 SL Symbol keypad V100-0001- PK Flight 60 SL Symbol keypad, Internal O2

Læs mere

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting LED Drivers CV EASYLINE CV 48 V EasyLine 48 V C-L 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V C-L VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT POWER

Læs mere

Low-Drop Voltage Regulator TLE 4276

Low-Drop Voltage Regulator TLE 4276 Low-Drop Voltage Regulator Features 5 V, 8.5 V, V or variable output voltage Output voltage tolerance 4% 4 ma current capability Low-drop voltage Inhibit input Very low current consumption Short-circuit-proof

Læs mere

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med

Læs mere

Engine Powered Forklift ton

Engine Powered Forklift ton Engine Powered Forklift 1. - 7.0 ton 8FGCU1-30 8FGC3U-70U www.toyota-forklifts. Engine Powered Forklift 1. - 1.7 tonne Truck specifications 8FGCU1 8FGCU18 1.1 Manufacturer TOYOTA TOYOTA 1.2 Model 8FGCU1

Læs mere

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080) Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Elektrisk aktuator Electric actuator Tekniske data Technical data

Læs mere

Hudevad P5 Easy Clean

Hudevad P5 Easy Clean Technical datasheet Key benefits Rengøring Unique tilting front Radiator front tilts away from the wall for easy access to cleaning the back of the radiator Classic Hudevad design Trademark Hudevad design

Læs mere

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL! DANSK INSTALLATIONSVEJLEDNING VLMT500 Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse. Kontroller at

Læs mere

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS). Bilag 8. TDC technical requirements for approval of splitters and inline s intended for shared access (ADSL or VDSL over POTS). Dette bilag udgør bilag 8 til det mellem parterne tiltrådte Produkttillæg

Læs mere

frame bracket Ford & Dodge

frame bracket Ford & Dodge , Rev 3 02/19 frame bracket 8552005 Ford & Dodge ITEM PART # QTY DESCRIPTION 1 00083 8 NUT,.50NC HEX 2 00084 8 WASHER,.50 LOCK 3 14189-76 2 FRAME BRACKET 4 14194-76 1 411AL FRAME BRACKET PASSENGER SIDE

Læs mere

MultiProgrammer Manual

MultiProgrammer Manual MultiProgrammer Manual MultiProgrammeren bruges til at læse og skrive værdier til ModBus register i LS Controls frekvensomformer E 1045. Dansk Version side 2 til 4 The MultiProgrammer is used for the writing

Læs mere

Komplet køreklar 6000 W Solcelle anlæg. Kr. 122.400,- inkl. moms

Komplet køreklar 6000 W Solcelle anlæg. Kr. 122.400,- inkl. moms Indeholder komplet system: Komplet køreklar 6000 W Solcelle anlæg Kr. 122.400,- inkl. moms 24 stk 250 W Monocrystalinske Full Black Solpaneler (ca.41m 2 ) 2 stk Dansk godkendte 3000 W Invertere med 10

Læs mere

Komplet køreklar 3000 W Solcelle anlæg. Kr. 71.400,- inkl. moms

Komplet køreklar 3000 W Solcelle anlæg. Kr. 71.400,- inkl. moms Indeholder komplet system: Komplet køreklar 3000 W Solcelle anlæg Kr. 71.400,- inkl. moms 12 stk 250 W Monocrystalinske Full Black Solpaneler (ca.20m 2 ) 1 stk Dansk godkendt 3000 W Inverter Diskret Full

Læs mere

YDEEVNEDEKLARATION. Nr DA

YDEEVNEDEKLARATION. Nr DA YDEEVNEDEKLARATION Nr. 0081 DA 1. Varetypens unikke identifikationskode: fischer boltanker FAZ II 2. Tilsigtet anvendelse: Produkt Moment-kontrolleret ekspansionsanker Anvendelsesområde/r Post-installeret

Læs mere

AQ70 Cylinder for water hydraulics

AQ70 Cylinder for water hydraulics AQ70 Cylinder for water hydraulics Dimensions AQ70 is a double acting hydraulic cylinder made entirely of stainless materials, designed for tap water as hydraulic fluid. Standard cylinder diameters from

Læs mere

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Unitel EDI MT940 June 2010 Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Contents 1. Introduction...3 2. General...3 3. Description of the MT940 message...3 3.1.

Læs mere

Ergonomisk løft. Specials. www.certex.dk. Højdestabler kasser High stacking boxes. Rulle løfter med 90º tilt Roll handling with 90º tilt

Ergonomisk løft. Specials. www.certex.dk. Højdestabler kasser High stacking boxes. Rulle løfter med 90º tilt Roll handling with 90º tilt Ergonomisk løft Højdestabler kasser High stacking boxes Rulle løfter med 90º tilt Roll handling with 90º tilt Kuffert løfter Baggage handling Håndtering af postpakker Handling of parcels Rudehåndtering

Læs mere

www.svovlbrinte.dk MeasureStar Hjælp til beskyttelse af dit kloaksystem

www.svovlbrinte.dk MeasureStar Hjælp til beskyttelse af dit kloaksystem MeasureStar Hjælp til beskyttelse af dit kloaksystem H 2 S Problem i kloaksystemet Produktionen og frigivelsen H 2 S gas i spildevandsystemer er ansvarlig for mange klager over lugt. Dog er destruktionen

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK). DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove Manual Transmission Remove and Install (,0 DOHC 8V Engine) (6 4 0) Workshop Equipment Transmission jack Materials Brake fluid (Super Dot 4) ESD-M6C57-A Remove. Standard preparatory measures: Make a note

Læs mere

Montageanvisning Assembly instructions. MultiDicer KMD 12, 18

Montageanvisning Assembly instructions. MultiDicer KMD 12, 18 Montageanvisning instructions MultiDicer KMD 12, 18 2 DK Kongskilde MultiDicer KMD 12 og KMD 18 samles som vist på efterfølgende tegninger. 1. Tegning 121117963 Kongskilde MultiDicer leveres fra fabrikken

Læs mere

Control cable YSLY-JZ/-JB/-OZ/-OB

Control cable YSLY-JZ/-JB/-OZ/-OB Control cable YSLY-JZ/-JB/-OZ/-OB CPR-performance: Eca Conductor material: copper, bare Conductor class: class 5 = fine stranded Insulation: PVC TI1 Sheathing material: PVC YM2 Colour outer sheath: grey

Læs mere

Navn: DVG V 450EC/F400 varenr.: 95257

Navn: DVG V 450EC/F400 varenr.: 95257 DVG-V 450EC/F400 varenr. 95257 Document type: Product card Document date: 2012-11-12 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

Beovox 5000 versions. Classic Audio Technical Information

Beovox 5000 versions. Classic Audio Technical Information Beovox 5000 versions Bang & Olufsen designed the Beovox 5000 for the Beolab 5000. During the period the Beolab 5000 was available (1967 1972) 3 different versions of the Beovox 5000 were released. In this

Læs mere

LF-8750 GENERATOR Industrial Park Road Van Buren, AR (866)

LF-8750 GENERATOR Industrial Park Road Van Buren, AR (866) LF-8750 GENERATOR 2205 Industrial Park Road Van Buren, AR 72956 www.lifanpowerusa.com (866) 471-7464 LF-8750 GENERATOR 1 GENERAL GASOLINE ENGINE 1 2 Bolt M6 12 29 3 Cylinder head cover Assy 1 4 Gasket,

Læs mere

SOT-363 Plastic-Encapsulate Transistors

SOT-363 Plastic-Encapsulate Transistors JIANGSU CHANGJING ELECTRONICS TECHNOLOGY CO., LTD SOT-363 Plastic-Encapsulate Transistors UMZ2N DUAL TRANSISTOR (PNP+NPN) FEATURES Both 2SA37AK and 2SC242K chip in a package Transistor elements are independent,

Læs mere

High Voltage AC & DC Film Capacitors

High Voltage AC & DC Film Capacitors RoHS COMPLIANT High Voltage AC & DC Film Capacitors Aerovox high voltage capacitors are constructed with metallized polypropylene film and are available in round or oval aluminum cases with four-blade

Læs mere

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 817-02

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 817-02 Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 817-02 For VA-godkendelse af et-grebs blandearmaturer. Page 1 of 11 INDHOLDSFORTEGNELSE FORORD... 3 ÆNDRINGER OG TILFØJELSER... 3 REFERENCER...

Læs mere

SR20 Cylinder for oil hydraulics

SR20 Cylinder for oil hydraulics SR20 Cylinder for oil hydraulics Dimensions SR20 is a double acting hydraulic cylinder made entirely of stainless steel. Standard cylinder diameters from ø25 mm up to and including ø80 mm. Application

Læs mere

Navn: DVG V 355EC/F400 varenr.: 95256

Navn: DVG V 355EC/F400 varenr.: 95256 DVG-V 355EC/F400 varenr. 95256 Document type: Product card Document date: 2012-11-12 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret 12-10-2011 /JLK

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret 12-10-2011 /JLK Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings QVEX Clima Revideret 12-10-2011 /JLK mit: JLK CC: Dato: 12-10-2011 Indhoidsfortegnelse I Table

Læs mere

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen [email protected] www.atexdirektivet.

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen stec@teknologisk.dk www.atexdirektivet. ATEX direktivet Vedligeholdelse af ATEX certifikater mv. Steen Christensen [email protected] www.atexdirektivet.dk tlf: 7220 2693 Vedligeholdelse af Certifikater / tekniske dossier / overensstemmelseserklæringen.

Læs mere

DEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark.

DEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark. CERTIFICATE Issued to: Applicant: ALIT S.r.l. ia Padania 6 20853 Biassono (MB) - ITALY Manufacturer/Licensee: ALIT S.r.l. ia Padania 6 20853 Biassono (MB) - ITALY Product(s) : Electronic controlgear for

Læs mere

Spare parts list ( ) HD 3.1/31 P

Spare parts list ( ) HD 3.1/31 P Spare parts list (15751070) HD 3.1/31 P 2010-07-07 www.kaercher.com EN Spare parts list HD 3.1/31 P (59704780)... 6 10 Frame (01031070)... 7 20 Pump set (01085070)... 9 21 Cylinder head (01085080)...

Læs mere

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 1111-01

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 1111-01 Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 1111-01 For VA-godkendelse af Termostatiske blandingsventiler. Page 1 of 11 INDHOLDSFORTEGNELSE FORORD... 3 ÆNDRINGER OG TILFØJELSER... 3 REFERENCER...

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. 67436 05/15 (OSH) 2015 OJ Electronics A/S

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. 67436 05/15 (OSH) 2015 OJ Electronics A/S INSTRUKTION 67436 05/15 (OSH) 2015 OJ Electronics A/S OJ-DV Hterm OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS GENERELT OJ-DV Hterm er en håndbetjeningsenhed, som anvendes til indstilling

Læs mere

Søjlesvingkraner type SK-C / Pillar swing crane type SK-C

Søjlesvingkraner type SK-C / Pillar swing crane type SK-C Søjlesvingkraner type SK-C / Pillar swing crane type SK-C Denne type søjlesvingkran anbefaler vi anvendt hvor der løftes og håndteres små lette byrder. Vort standard program er således designet i belastningsgrupper

Læs mere

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400 BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400 BETJENINGSVEJLEDNING 1. Vigtigt: Før du tilslutter spændingstransformerne til stikkontakten i dit hjem, skal du sørge

Læs mere

No. Part No. Description Q ty Remarks Cleaner Assembly (Includes Fig.1,2,4 & 5) Cap Tube, inlet Filter, air cleane

No. Part No. Description Q ty Remarks Cleaner Assembly (Includes Fig.1,2,4 & 5) Cap Tube, inlet Filter, air cleane No. Part No. Description Q ty Remarks 1 050601 Cleaner Assembly (Includes Fig.1,2,4 & 5) 2 050602 Cap 3 050603 Tube, inlet 4 050604 Filter, air cleaner 5 050605 Net, air cleaner No. Part No. Description

Læs mere

3A Step-Down Voltage Regulator

3A Step-Down Voltage Regulator 3A Step-Down Voltage Regulator DESCRIPITION The series of regulators are monolithic integrated circuits that provide all the active functions for a step-down (buck) switching regulator, capable of driving

Læs mere