ELECTRONIC CONTROL BOX 20-0313



Relaterede dokumenter
ELECTRONIC CONTROL BOX

ELECTRONIC CONTROL BOX

ELEKTRONISK STYRETAVLE & SYSTEM 500 DIGITAL

1-Funktions multitavle Aquatronic

WIO200A INSTALLATIONS MANUAL Rev Dato:

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

QUICK START Updated:

QUICK START Updated: 18. Febr. 2014

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

WIO200A Water in oil sensor

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

MS-H280-Pro Magnetic Stirrer

Varenr.: højre venstre º højre med coating º venstre med coating

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL UNI-EL Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

TDC 4 Indoor voltage transformers

Montage og brugermanual til IMage spa touch & styretavler. Alle modeller.

frame bracket Ford & Dodge

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

UNISONIC TECHNOLOGIES CO.,

Farvekoder på vejeceller leveret af NTT fra 2017

HR7775, HR indd :28

Digital positioner type RE 3446

Brugsanvisning. Installation Manual

Sikkerhedsvejledning

Manual. IMage Elektronisk styring med varmeregulering. Type

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17

Navn: DVG V 450EC/F400 varenr.: 95257

1. Basic safety information 3 2. Proper use 3

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

Video Projector Controller. Brugermanual

WATER BATH I Instruction Manual. Water Bath. Digital Control. Cat. No

Navn: DVG V 560EC/F400 varenr.: 95135

Montageanvisning Assembly instructions. MultiDicer KMD 12, 18

MultiProgrammer Manual

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

INSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960!

Modulerende kuglehane

Ergonomisk løft. Specials. Højdestabler kasser High stacking boxes. Rulle løfter med 90º tilt Roll handling with 90º tilt

Installationsmanual 4-Device-Control Boks

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001


ROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning. ROTATING SHOWER STOOL WITH TRAY Installation Manual. Size: 148 x 210 mm 105g copper paper

TGP 15 H. Betjeningsvejledning. Texas Power Line Pumper 2003 / 2

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

DX-610/DX-626 6CH.DMX DIMMER PACK

Specifikationer: Producer: Unitron a/s Kokmose 6, 6000 Kolding. Tlf Fax

TranzX P ST PCB Kit Manual Vers ion C, D & E. Alle E-Fly. Vælg I2C. Vælg I2C PCB kit version og serienummer

5-24 TALJER, KRANER & SPIL / HOISTS, CRANES & WINCHES

TRÆNINGS COMPUTER PEAK FITNESS R99

Brugermanual for drænpumpe

SkyVision Linear Installation manual, comfort _0216, Comfort, Item no Version 02/16

Beovox 5000 versions. Classic Audio Technical Information

WI180C-PB. Online-datablad

Delta Elektronik A/S - AKD

Vejledning til at tjekke om du har sat manuel IP på din computer.

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

Hudevad P200. Technical datasheet

Lithium-Ion Jump-Starters / Jumper Cables

NoteSync vejledning. Leba Innovation A/S

Privat-, statslig- eller regional institution m.v. Andet Added Bekaempelsesudfoerende: string No Label: Bekæmpelsesudførende

Læs vejledningen godt igennem, før du begynder at samle vuggen. Please read the instruction carefully before you start.

Diamond Core Drilling

INSTALLATIONS OG BRUGERVEJLEDNING JAKA FD. Læs denne instruktion omhyggeligt før installation/brug.

Brugervejledning / User manual

SAMLEVEJLEDNINGER / COLLECTION GUIDES

Date of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO

Special VFR. - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

Xperia TX TV Dock DK22 Xperia T TV Dock DK23

Elma DT 802D CO2 logger. Dansk/Norsk 2 English 4 EAN:

Technical Specifications

Vina Nguyen HSSP July 13, 2008

STREETLIGHT IP. Produktfamilie datablad. LED moduler til udendørs applikationer

RPW This app is optimized for: For a full list of compatible phones please visit radiation. result.

Hudevad P5 Easy Clean

IPTV Box (MAG250/254) Bruger Manual

Programmable pressure transmitters PTM

Brugervejledning. MHL to HDMI Adapter IM750

Ventilation. Du skal selv være med til at holde din lejlighed sund You are responsible too: keep your apartment healthy

Plug Connectors for Food & Beverage

W W W W W S S S S S 6 P3 P2 P1 7 Fig.1

Brugervejledning. Xperia P TV Dock DK21

Bookingmuligheder for professionelle brugere i Dansehallerne

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

Navn: DVG V 450EC/F400 varenr.: 95257

Brugervejledning. Trådløs HD Sender & Modtager Sæt

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

No. Part No. Description Q ty Remarks Cleaner Assembly (Includes Fig.1,2,4 & 5) Cap Tube, inlet Filter, air cleane

SmartDock for Xperia ion Brugervejledning

Advarsel: Læs alle instrukser og færdiggør samlingen før brug. Det kan være en fordel at være to til at samle trampolinen.

DK...Infrarød fjernbetjening Combi-lås Skiftespor Drejeskive Rumdækkende Travers DH2000

Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov.

United Nations Secretariat Procurement Division

Constant Terminal Voltage. Industry Workshop 1 st November 2013

No Part no. Description Q ty Remarks No Part no. Description Q ty Remarks Filter, air cleaner Air cleaner 1 Assy 2 050

Transkript:

ELECTRONIC CONTROL BOX 20-0313 Specifications Rated voltage: Rated power: Rated current: Output A: Output B: Output C: 230VAC, 50Hz, single phase 2300W 10 A Max. 900W The total sum of the loads must not exceed the rated power and current. Dimensions & temperature Weight: 0.9 kg Length: 200 mm Width: 150 mm Depth: 80 mm Operating temperature: 0 to 50 C Storage temperature: -20 to 50 C Important This control box is not suitable for medical use. Follow the directions for installation and connection. We reserve the right to change the product and the specification without notice. Safety rules A. Locate the box in a dry area with good ventilation. B. The box must be situated at least 3 cm above the ground floor. C. Before cleaning, servicing, exchanging of parts or accessories or checking up on various disturbances, the mains have to be cut off. D. Make sure that there are no unconnected wires and cables inside the box. E. Cables and wires must be as short as possible inside and outside the box. F. The box is protection Class I. It has to be connected with cables according to the instructions from EN 60335-1 and EN 60335-2-60. It is recommended that you consult a state registered electrician. The supply cable has to be minimum type H05VV-F; 3G1.5 mm 2. G. Keep at all time minimum 20 mm distance between high and low power cables. H. In order to separate the box from the mains you must install a suitable ground fault circuit interrupter with at least 3 mm break distance on each terminal in the present electrical installation. I. The mounting is to be made in such a way that it is not possible to touch the electric parts. J. The electric parts have to be mounted in such a way that they cannot fall into the bathtub. K. Instruments of Class I must be connected to a permanent installation. L. Be aware that some countries have requirements about power indication. M. Tighten all cable glands sufficient by means of a tool to ensure that the Ingres protection is IPX5 and to ensure that the cables are fixed in position and protected for physical traction and pressure. N. If not all cable outlets are used, the cable gland(s) in question has to be changed to dummy plug(s) of the same dimension to ensure that the Ingres Protection still is IPX5. O. This appliance is not intended for use by persons, including children with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible for their safety. P. Children should be supervised to ensure that they do not play with the appliance.

ELECTRONIC CONTROL BOX 20-0313 Cabling and wiring 1. Connect 12V water level sensor to the terminal marked: LEVEL. 2. Connect touch (max. 4-function) to terminal marked: CONTROL PANEL. 3. Connect 230VAC blower to terminal marked: A (and if necessary to earth). 4. Connect pump or other 230 VAC equipment to terminal marked: B (and if necessary to earth). 5. Connect underwater light or other 230 VAC equipment to terminals marked: C (and if necessary to earth). 6. Connect control box to power, 230 VAC, via terminals marked MAINS: L1, N & EARTH. Initial settings Blower maximum and minimum speed can be set by following steps below: Connect power to the control box. Within 60 seconds of connecting the power, press blower up/down & blower on/off simultaneously for 5 sec. The blower will start and blower on/off will flash twice. Press blower up/down to the desired minimum speed and press blower on/off to store the setting. Blower on/off flashes with high frequency. Press blower up/down to the desired maximum speed and press blower on/off to store the setting. Blower on/off will light for 2 seconds and blower will stop to indicate end of settings. Functional description Power indicator Pump will flash every 10 seconds to indicate power is connected to the system. Water level indicator Pump will flash every second to indicate adequate water in the bathtub. Function indicator If pump, blower or light is activated, for each function will light up. Dry blowing indicator Blower will flash during the automatic dry blowing program. Automatic dry blowing program The program will start after water level sensor indicates low level. After 20 minutes, the blower will run for 1 minute. During the dry blowing program the program can be stopped at any time by pressing the blower button. The program will only start if the pump function has been used. The dry blowing program can be disabled with a terminal strap between AUX IN and COMMON. Manual dry blowing It is possible to do manual dry blowing of air channels, by pressing the blower button without water in the bathtub. Pulsation Is activated/deactivated by pressing and holding the blower button for 3 seconds. The blower will pulsate between minimum and the current speed (see under Initial settings). Boost (stop/start of blower) Boost is activated by holding down the blower button for 3 seconds, when the pulsation is running. It is stopped by pressing the blower button once. The boost function is when the blower stops and stars with 2.5 seconds interval. A built in timer Switches off all functions after 30 minutes. The water level sensor dominates all functions and will shut off everything in case of inadequate water.

ELECTRONIC CONTROL BOX 20-0313 Connection diagram MAX. 10A MAX. 10A AUX IN BROWN BLACK BLUE GND I E F G H LIGHT PUMP AIR CONTROL PANEL LEVEL SAFETY BLUE PURPLE BLACK WHITE BROWN YELLOW GREEN GREY RED A MAINS HEAT B C D AIR PUMP LIGHT

ELECTRONISK KONTROL BOKS 20-0313 Specifikationer Mærkespænding: 230V, 50Hz, 1 fase. Mærkeeffekt: 2300 W Mærkestrøm: 10 A. Udgang A: Udgang B: Udgang C: Max. 900W Summen af belastninger må ikke overstige mærkeeffekt og mærkestrøm. Dimensioner & temperatur Vægt: 0.9 kg Længde: 200 mm Bredde: 150 mm Dybde: 80 mm Arbejdstemperatur: 0 til 50 C Opbevarings temperatur: -20 til 50 C Vigtigt Kontrolboksen er ikke egnet til medicinsk brug. Følg altid instruktionen under montering og tilslutning. Vi forbeholder os ret til at ændre i produktet og manualen uden varsel. Sikkerhedsregler A. Boksen anbringes på et tørt og godt ventileret sted. B. Boksen skal anbringes mindst 3 cm over gulvet. C. Strømtilførslen skal altid afbrydes før rensning, reparation, udskiftning af reserve dele eller tilbehør, og ved undersøgelse af evt. uregelmæssigheder. D. Der må ikke forefindes utilsluttede kabler eller ledninger inde i boksen. E. Kabler og ledninger skal være så korte som muligt både indeni og udenfor boksen. F. Kontrol boksen er henhørende i sikkerhedsklasse I, og må kun elektrisk forbindes i overensstemmelse med EN 60335-1 og EN 60335-2-60. Det anbefales, at De rådfører Dem med en autoriseret elinstallatør. Tilslutningskablet skal som minimum være type H05VV-F; 3X1,5 mm 2. G. Der skal være en afstand på mindst 20 mm mellem stærk- og svagstrømskabler. H. Boksen skal adskilles fra nettet af en kontakt med en brydeafstand på min. 3 mm på hver pol. I. Installeringen skal foretages således, at det ikke er muligt for brugeren at berøre elførende dele. J. Alle elektriske dele skal være således monteret, at der ikke er mulighed for at disse kan falde ned i karret. K. Apparater af Klasse I skal være forbundet til en fast installation. L. Vær opmærksom på at nogle lande har krav om synlig spændingsindikation. M. Spænd alle kabel forskruninger tilstrækkeligt ved hjælp af værktøj for at sikre IPX5 tæthedsgraden samt for at aflaste kablet. N. Hvis ikke alle kabel forskruninger anvendes, skal de udskiftes til blænd propper for at sikre IPX5 tæthedsgraden. O. Udstyret er ikke beregnet til brug for personer, inkl. børn, med fysiske eller mentale handikap eller personer uden erfaring eller viden i brugen. Der bør gives instruktion i brugen af installationen af hensyn til deres sikkerhed. P. Børn bør overvåges, for at sikre at de ikke leger med installationen.

ELEKTRONISK KONTROL BOKS 20-0313 Kabel- og ledningstilslutninger 1. Tilslut 12V vandstandssensor til klemmerækken mærket LEVEL. 2. Tilslut touch (maks. 4-funktionstouch) til klemmerækken mærket: CONTROL PANEL. 3. Tilslut 230 VAC blæser til klemmerækken mærket A (samt Jord om nødvendigt). 4. Tilslut pumpe eller andet 230 VAC udstyr til klemmerækken mærket B (samt Jord om nødvendigt). 5. Tilslut lampe eller andet 230 VAC udstyr til klemmerækken mærket C (samt Jord om nødvendigt). 6. Tilslut kontrol boksen til lysnettet, 230 VAC, via klemmerækken mærket MAINS: L1, N & JORD. Grund indstillinger Blæser maksimum og minimum hastighed kan indstilles på følgende måde: Tilslut strøm til kontrol boksen. Inden 60 sekunder efter strøm tilslutning, aktiveres blæser on/off & blæser op/ned samtidig i 5 sek. Blæseren vil starte og dioden for blæser on/off vil blinke to gange. Hold blæser op/ned knappen nede, til den ønskede minimum hastighed. Tryk på blæser on/off for at gemme indstillingen. Efterfølgende vil dioden for blæser on/off blinke hurtigt. Hold knappen blæser op/ned nede, til den ønskede maksimum hastighed. Tryk på blæser on/off for at gemme indstillingen. Efterfølgende vil dioden blæser on/off lyse i 2 sekunder og blæseren stopper. Dette vil indikere, at indstillingerne er gemt. Funktionsbeskrivelse Strøm indikation Pumpe dioden vil blinke hver 10. sekund for at indikere, der er strøm på systemet. Vandstandsindikation Pumpe dioden vil blinke hvert sekund for at indikere korrekt vandstand i karret. Funktionsindikation Når pumpe, blæser eller lys er aktiveret vil tilhørende diode lyse. Tørblæsningsindikation Når tørblæsningsprogrammet kører vil dioden for blæser blinke. Automatisk tørblæsningsprogram Aktiveres automatisk når vandstandssensoren indikerer lav vandstand og pumpen har været i brug. Blæseren starter 20 minutter efter aktivering og kører i 1 minut. Programmet kan afbrydes ved at trykke på blæser knappen. Hvis automatisk tørblæsningsprogram ikke ønskes, kan dette undgås ved at montere en lus mellem AUX IN og COMMOM. Manuel tørblæsning Det er muligt at køre manuel tørblæsning af luft systemet, ved at aktivere blæser knappen. (Dette kræver ikke, at der har været vand i karret) Pulsering Pulsering af blæser aktiveres/deaktiveres ved at holde blæser knappen nede i 3 sekunder. Blæseren vil pulsere mellem den aktuelle hastighed og til minimum. (Minimum hastighed kan indstilles. Se Grund indstillinger ). Boost (stop/start af blæser) Boost aktiveres ved at holde blæser knappen nede 3 sekunder, når pulsering kører. Stoppes ved et tryk på blæser knappen. Boost funktionen er, at blæser stopper/starter med 2,5 sekunders interval. Indbygget timer Den indbyggede timer vil afbryde alle funktioner efter 30 minutter. Alle udgange er vandstands afhængige og vil derfor afbrydes ved for lav vandstand.

ELEKTRONISK KONTROL BOKS 20-0313 Tilslutningsdiagram MAX. 10A MAX. 10A AUX IN BROWN BLACK BLUE GND I E F G H LIGHT PUMP AIR CONTROL PANEL LEVEL SAFETY BLÅ LILLA SORT HVID BRUN GUL GRØN GRÅ RØD A MAINS HEAT B C D AIR PUMP LIGHT