ScopeMeter bærbare oscilloskoper



Relaterede dokumenter
Fluke ScopeMeter 120 serien

Fluke ScopeMeter 190 serien

Fluke 170 Serie Sand RMS Digitale Multimetre

Introduktion af den komplette 190 Serie II Tekniske data

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

Delta Elektronik A/S - AKD

Fluke Connect moduler Tekniske data

Storage oscilloscope

Basic statistics for experimental medical researchers


E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

MultiProgrammer Manual

Vina Nguyen HSSP July 13, 2008

Fluke 43B. Power Quality Analyzer. Kom godt i gang

Fluke 370 FC Serie Trådløst sand RMS AC/DC tangmeter

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1

CHAPTER 8: USING OBJECTS

DET KONGELIGE BIBLIOTEK NATIONALBIBLIOTEK OG KØBENHAVNS UNIVERSITETS- BIBLIOTEK. Index

Nu 1080,- Tilbud gælder til og med 31. marts 2012

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

Hvor er mine runde hjørner?

Fluke tangmetre Løsninger til alle opgaver

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Brug sømbrættet til at lave sjove figurer. Lav fx: Få de andre til at gætte, hvad du har lavet. Use the nail board to make funny shapes.

FLUKE. Fluke 177 digitalt multimeter, nu med det bløde C25 etui med 14% rabat, og få en GRATIS Bluetooth højttaler!

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400

STEVISON BLUETOOTH USB MICRO SD DAB+ FM DIGITAL RADIO

FLUKE SE DET. GEM DET. DEL DET. Fluke 117 digitalmultimeter. Særlige kampagnetilbud på alle Fluke multi-installationstestere.

STEVISON BLUETOOTH USB MICRO SD DAB+ FM DIGITAL RADIO

PARALLELIZATION OF ATTILA SIMULATOR WITH OPENMP MIGUEL ÁNGEL MARTÍNEZ DEL AMOR MINIPROJECT OF TDT24 NTNU

Nem logning: Hurtig logning og overvågning af målinger

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

WT-1011RC Programmer User Guide

The X Factor. Målgruppe. Læringsmål. Introduktion til læreren klasse & ungdomsuddannelser Engelskundervisningen

Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov.

Aktivering af Survey funktionalitet

Brugervejledning. MHL to HDMI Adapter IM750

how to save excel as pdf

UNISONIC TECHNOLOGIES CO.,

Varenr.: højre venstre º højre med coating º venstre med coating

Privat-, statslig- eller regional institution m.v. Andet Added Bekaempelsesudfoerende: string No Label: Bekæmpelsesudførende

USERTEC USER PRACTICES, TECHNOLOGIES AND RESIDENTIAL ENERGY CONSUMPTION

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

Brugermanual. EnVivo Cassette Converter

Video Projector Controller. Brugermanual

Xperia TX TV Dock DK22 Xperia T TV Dock DK23

WT-1011RC Programmer User Guide

Trolling Master Bornholm 2016 Nyhedsbrev nr. 3

PMDK PC-Side Basic Function Reference (Version 1.0)

USER GUIDE Version 2.9. SATEL Configuration Manager. Setup and configuration program. for SATELLINE radio modem

Totally Integrated Automation. Totally Integrated Automation sætter standarden for produktivitet.

Vejledning til at tjekke om du har sat manuel IP på din computer.

User Manual for LTC IGNOU

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

Central Statistical Agency.

WIO200A Water in oil sensor

RoE timestamp and presentation time in past

Sunlite pakke 2004 Standard (EC) (SUN SL512EC)

3D NASAL VISTA 2.0

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

Brugervejledning. Xperia P TV Dock DK21

QUICK MANUAL BRUGERNAVN: ADMIN PASSWORD: APP: SMARTEYES PRO PORT: SecVision - Quick Manual v1.0

Kun klassens bedste er god nok

Engelsk. Niveau D. De Merkantile Erhvervsuddannelser September Casebaseret eksamen. og

3D NASAL VISTA TEMPORAL

ELCANIC A/S. ENERGY METER Type ENG110. Version Inkl. PC program: ENG110. Version Betjeningsvejledning

Lithium-Ion Jump-Starters / Jumper Cables

Fundamentals of HVAC Control Systems

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

HN Brugervejledning. Læs brugervejledningen omhyggeligt før multimeteret tages i brug, og gem brugervejledningen til senere brug.

SmartDock for Xperia ion Brugervejledning

Help / Hjælp

Quick Setup Guide SB168-ES og M7CL Dansk version

Black Jack --- Review. Spring 2012

LET TILGÆNGELIG ENERGI OVERALT

Maskindirektivet og Remote Access. Arbejdstilsynet Dau konference 2015 Arbejdsmiljøfagligt Center Erik Lund Lauridsen

2x50 ETHERNET MODUL. RS485 slave med Ethernet-IP. Gælder for: Program nr.: AUXSLAVE v1 Dokument nr.: 0422md2x50-2v1 Dato:

Elma DT 802D CO2 logger. Dansk/Norsk 2 English 4 EAN:

Status på det trådløse netværk

Trolling Master Bornholm 2014

IPTV Box (MAG250/254) Bruger Manual

Lovkrav vs. udvikling af sundhedsapps

CERTIFICATE OF ACCREDITATION

VLSI Design. DC & Transient Response. EE 447 VLSI Design 4: DC and Transient Response 1

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

Statistik for MPH: 7

Brugervenlig og kommunikativ!

Impac230. Beskrivelse. Egenskaber. Impac 230

OG-3600 Series Fiber Optic Transport for opengear card frame platform w/ SNMP Management

Boligsøgning / Search for accommodation!

Fjernbetjening Flex Teknisk manual

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

X M Y. What is mediation? Mediation analysis an introduction. Definition

QUICK START Updated: 18. Febr. 2014

TDC 4 Indoor voltage transformers

Brugermanual. 2GB MP3 afspiller

DENCON ARBEJDSBORDE DENCON DESKS

NoteSync vejledning. Leba Innovation A/S

Transkript:

ScopeMeter bærbare oscilloskoper ScopeMeter bærbare oscilloskoper giver dig mulighed for at komme til områder, hvor bordoscilloskoper ikke kan komme: Hvor det er hårdt, farligt og beskidt - uden at gå på kompromis med nogen af egenskaberne. De leverer en hidtil uset hastighed, ydeevne og analyseevne, mens de arbejder på stedet. Se vores seneste videoer på vores egen YouTube kanal www.youtube.com/user/flukeeuropexx 97

ScopeMeter 190 serie II De mest robuste bærbare oscilloskoper, der nogensinde er bygget 190 Serie II i en nøddeskal: 190 Serie II dækker båndbredden fra 60 MHz til 500 MHz med ScopeMeter modeller 190-XX4 modeller med fire uafhængige isolerede indgange og DMM udlæsning 190-XX2 modeller med to uafhængige isolerede oscilloskopindgange og en DMM indgang Op til fire brugervalgbare kanaler Op til 33 brugervalgbare udlæsninger Hurtig samplingshastighed op til 5 Gs/s med op til 200 ps opløsning Single shot, pulsbredde og videotrigning Dyb hukommelse: 10.000 punkter pr. spor kurveformsfangst KAT III 1000 V/KAT IV 600 V sikkerhedsklassificeret IP 51 klassificeret: Støv- og stænktæt Isolerede USB porte til hukommelsesenheder og pc tilslutningsmuligheder Op til syv timers drift med højtydende litium-ion batterier Nem adgang til batterirummet Sikkerhedsudskæring til låsning af instrumentet med Kensington standardlås. Connect-and-View trigning til intelligent, automatisk trigning på hurtige, langsomme og endda komplekse signaler Konvertering til frekvensdomæne ved brug af FFT analyse Automatisk optagelse og afspilning af 100 skærmbilleder ScopeRecord funktionen giver 30.000 punkter eller mere pr. indgangskanal til analyse af lavfrekvenssignaler. Trendplot papirløs optagefunktion med dyb hukommelse for langsigtet logning af automatiske målinger. De mest robuste bærbare oscilloskoper, der nogensinde er bygget Fluke introducerer 500 MHz versionen udstyret med 4 isolerede kanaler. Dette nye ScopeMeter testværktøj, model 190-504, giver sin brede båndbredde i din hule hånd med maksimal fleksibilitet af målekanaler. Det er nemt at verificere system performance lige på stedet, og det sker i fuld sikkerhed, uden at du skal bære rundt på uhåndterligt laboratorieudstyr. Hvad kan du udrette med fire kanaler? 190-504 åbner op for en ny generation af applikationer, hvor et firekanals ScopeMeter kan bevise sin funktionalitet. Du kan tilslutte spændingsprober og strømtænger i kombination med en temperaturprobe for at få den bedste information ud af dine signaler uden at ofre en probeindgang. I et motor- og drevmiljø skal du bruge mindst tre indgange for at få et godt indblik i kvaliteten af det signal, der kommer fra VFD en. Du kan skifte over til en DMM læsning uden at bytte om på prober. Klassificeret hele vejen til KAT IV ScopeMeter testværktøjer er robuste løsninger, der er bygget til industriel fejlfinding. Fluke 190 serie II er dobbeltisolerede oscilloskoper med svævende indgang og sikkerhedsklassificeret for målinger op til KAT III 1000 V/KAT IV 600 V miljøer. Den nye 500 MHz model er klassificeret til 600 V KAT III hele vejen op. Udfør sikre målinger fra mv til kv Med uafhængige isolerede indgange kan du foretage målinger i blandede kredsløb, der har forskellige jordreferencer, hvilket reducerer risikoen for utilsigtede kortslutninger. Traditionelle bordoscilloskoper uden specielle differentielle prober og isoleringsomformere kan kun udføre målinger med reference til jord. Med standardprober, der dækker en lang række anvendelsesområder fra mv til kv, er du klar til alt lige fra mikroelektronik til kraftige elektriske applikationer inden for højspændinger. IP-51 klassificeret til barske miljøer Alle bærbare ScopeMeter oscilloskoper er robuste og stødsikre og bygget til anvendelse i hårde og beskidte omgivelser. Med dets forseglede kabinet kan det modstå støv, stænk, fugt og luftbårne forurenende stoffer. Hver gang du bruger ScopeMeter, kan du være sikker på, at det fungerer pålideligt, uanset hvad du skal lave. 98

ScopeMeter 190 serie II Nyhed Ny USB tilslutningsmulighed gør det nemt at fange og dele kurveformer Den nye Fluke 190 serie II indeholder to USB porte, der er elektrisk isoleret fra måleindgangskredsløb. Nem overførsel af data til en pc. Arkiver og del kurveformer med OEM er, kolleger og supportmedarbejdere. Gem kurveformer, skærmbilleder og instrumentopsætninger på USB hukommelsesenheder. Connect-and-View trigning for at opnå et øjeblikkeligt, stabilt billede Fluke 190-504 Hvis du har brugt andre oscilloskoper, ved du, hvor svært trigning kan være. Hvis indstillingerne er forkerte, kan resultaterne være ustabile eller forkerte. Connect-and-View indstiller automatisk korrekt trigning ved at genkende signalmønstre. Du kan helt uden at trykke på en knap få stabil, pålidelig og repetérbar visning af stort set alle signaler inklusive frekvensomformer og styresignaler. Det er især hurtigt og praktisk, når du måler en række testpunkter hurtigt efter hinanden. Automatisk indfangning og gentagelse af seneste 100 skærmbilleder Connect-and-View registrerer selv de mest komplekse frekvensomformersignaler. Fluke 190-202 Skopbrugere ved, hvor frustrerende det er at se en engangsafvigelse fare forbi for aldrig at dukke op igen. Det sker ikke med ScopeMeter 190 serien! Nu kan du se tilbage i tiden med tryk på en knap. Ved normal brug husker instrumentet kontinuerligt de seneste 100 skærmbilleder. På et hvilket som helst tidspunkt kan du fryse de seneste skærmbilleder og rulle igennem dem billede efter billede eller gentage dem som en live animation. Markører og zoom kan bruges til yderligere analyse. Du kan endda bruge de avancerede trigningsfunktioner til at indfange op til 100 specifikke hændelser. To sæt med 100 skærmbilleder med individuelle tidsstempler kan gemmes og hentes frem senere eller downloades til en pc. Se øjeblikkeligt dynamiske signalers adfærd Den nye funktion Digital Persistence hjælper med at finde afvigelser og analysere komplekse dynamiske signaler ved at vise kurveformers amplitudefordeling over tid med flere intensitetsniveauer og brugervalgt efterglød - det er som om man ser på skærmen på et analogt oscilloskop i realtid! En stor skærmopdateringshastighed afslører signalændringer øjeblikkeligt, dette er for eksempel nyttigt, når man foretager justeringer af et system, der testes. Fluke 190-204 Sand RMS Indbygget 5000 trin digitalt multimeter (2 kanaler) 190 serie II modeller med isolerede dobbelt indgangoscilloskop og dedikeret digitalt multimeter. Skift nemt fra kurveformanalyse til præcise multimetermålinger ved hjælp af det indbyggede 5000 trins digitale multimeter. Målefunktioner omfatter Vdc, Vac, Vac+dc, modstand, gennemgang og diodetest. Mål strøm og temperatur ved hjælp af egnet shunt, probe eller adapter med et bredt udvalg af skaleringsfaktorer. Det indbyggede multimeter giver enkle præcisionsmålinger Se alt ekstratilbehør til Fluke 190 serien på side 102 99

It frequently happens that service are automatically detected and engineers have to spend a lot of adjusted, followed by displaying the signal in the correct ratio time adjusting their measuring device such as a portable oscilloscope for an optimal setting. and vertical axis. At least 1.5 with respect to the horizontal Valuable time is spent completing to 4 periods of the signal are this set up, and ideally, this could measured before the pattern is be done automatically. shown. With the introduction of the Connect and View provides new ScopeMeter 190 Series II, a stable, reliable and repeatable display of virtually any Fluke has revamped its unique feature, Connect and View. signal, including motor drive and Scope users know how difficult triggering can be. Wrong ing a button. Signal changes are control signals, without touch- settings show unstable and instantly recognized and settings sometimes wrong results. Fluke s adjusted for, once again, a stable unique Connect and View display. This is all done automatically, but manual overruling recognizes signal patterns, and automatically sets up correct is still possible. If manual overruling is needed, the ScopeMeter triggering, attenuator and time base settings. Switching on the 190 Series will switch from automatic to 1/2 automatic, which is ScopeMeter portable oscilloscope to display correct signal patterns visible on the display. only takes a couple of seconds, Figure 1 gives an example of and this is exactly what an the different types of waveforms operator wants. which can de detected by Settings regarding Connect & View. If required the amplitude, criteria for best settings can be AC/DC coupling timebase, optimized by switching on one or Glitch detect triggering, all of the following options: Figure 2 shows the different etc. Automatic trigger settings. Figure 1. From the Fluke Digital Library @ www.fluke.com/library 75 Ω ScopeMeter 190 serie II Produktionssystemer 190 Series II Testing telecommunication equipment using Pass/Fail mask testing with a Fluke ScopeMeter G.703 is a standard originally introduced for voice and data transmission over digital networks. It an ITU recommendation (formerly CCITT) that s associated with the PCM standard. Analog-voice to digitaldata conversion according to PCM requires a bandwidth of 64 kb/s (±100 ppm), resulting in the basic unit for G.703. Through multiplexing this results in a T1 of 1.544 Mb/s and E1 of 2.048 Mb/s. The electrical characteristics of the network interfaces are described in recommendation G.703. The signal limits for a 2.048 Mb/s signal are shown in Figure 1. The G.703 standard Multiple-channel testing using two different masks Application Note Nowadays digital communication systems such as Synchronous Digital Hierarchy (SDH) in Europe and the Synchronous Optical Network (SONET) in North America require standard test methods. The electrical signals are tested against the standard ITU pulse masks. The Fluke ScopeMeter 190 Series II portable oscilloscope offers a standard pass/fail function that can be used to perform these tests. The instrument is capable of storing up to 100 fails for further analysis. Demystifying drive anomalies using the Fluke 190 Series II 2-Channel ScopeMeter portable oscilloscope Testing Functions Case Study Measuring tools: 190 Series II 2-Channel ScopeMeter Operator: Chris Vogel, HVAC Technician for Siemens Building Technologies Figure 1. G703 - E1 template A balun is used between the patch panel and a coaxial transmission line to match the impedance of the 120 Ω symmetrical line to a 75 Ω coaxial line. The input and output of the balun each has its specific mask. The ScopeMeter 190 Series II portable oscilloscopes can simultaneously perform a pass/fail test at the input and output of the balun with different masks. The floating and isolated With FlukeView we can export inputs of the Fluke ScopeMeter a waveform into a spreadsheet 190 Series II test tools make and a custom template can be these measurements possible without the risk of making using Excel. created by editing a waveform unwanted groundings. Moreover, A reference template for the high impedance probes allow pass/fail testing can be created by saving waveforms from for direct measurements without loading the line and without the FlukeView in.csv format and need for an external differential editing the waveform using, for Test Tool probe. Editing the pass/fail templates Measurements: Current and voltage waveform analysis, power factor Telephone Exchange 2 Mb/s 120 Ω ISDN 30 Figure 2. ISDN30 network Application Note Connect the ScopeMeter test tool and view the result: the start of every measurement Seeing is believing? More aptly, seeing is understanding. Patch Panel Balun SDH Distr. F r o m t h e F l u k e D i g i t a l L i b r a r y @ w w w. f l u k e. c o m / l i b r a r y 2 Mb/s 120 Ω If anyone can wring every last ounce of functionality out of a piece of electronic test equipment, it s Chris Vogel. At Siemens Building Technologies, Vogel has his work cut out for him keeping HVAC systems running for the company s large commercial customers in Florida s tropical weather, which is marked by seemingly nonstop 90 F temperatures and 95 % humidity levels. And that s just one of the challenges faced by technicians at Siemens Building Technologies, which plays a more sweeping role in its customers success: ensuring energy efficiency, comfort, protection against unauthorized access, and fire safety year-round for every building or office tower entrusted to it by customers. Vogel, an HVAC technician, becomes energized when discussing the return on investment It s important, says Vogel, in his handheld that the technician be able to ScopeMeter Test Tool. Out at one large site, characterize VFD problems by where we monitor and troubleshoot variable frequency drives capturing a waveform from the offending drive. His premise: A (VFDs), component-level repair signal is much more telling when can often mean the difference presented in a waveform view between a $20 repair part and than in a single, static voltage reading. The signal has a a $100,000 repair bill. I know firsthand, because we recently shape and value that may look documented that very scenario. right at a glance, but could just On large VFDs, Vogel uses his as easily have a distortion or ScopeMeter portable oscilloscope rough edge, or a momentary to uncover capacitance problems, spike almost too short to be transistor firing mishaps, and seen. Either problem, or a host even bleed-throughs on a gate. of other signal anomalies, would Of course, a transistor is basically a lightning-fast switch, be indistinguishable with just a numeric reading of the signal. he says. It switches back and The scope allows me to forth between open and closed, record information, and from a and it can sometimes start to number of sources sine waves break down. When that happens, on the inputs and outputs of motors will start doing weird VFDs, current and voltage and, things. For example, at load for that matter, make comparisons of current and voltage so stage we ll actually see the motor banging back and that I can derive a power factor forth as if it is not sure which for the circuit. way to turn. Storing a slice of time F r o m t h e F l u k e D i g i t a l L i b r a r y @ w w w. f l u k e. c o m / l i b r a r y 2 Mb/s Application Note En række anvendelsesnoter er tilgængelige. Se Flukes websted: www.fluke.dk Find problemer i industrielle systemer, inklusive: Tomgangsspænding/strømoverbelastning Attenuering/indgangsimpedans mismatch Signalfluktuationer/drift Konditionering af integritet af kredsløbssignaler Test punktverifikation for kritiske signaler Timingproblemer for indgang/udgang/feedback Induceret støj og forstyrrelser Tilfældige nedlukninger/nulstillinger Diagnosticering af VSD er* eller strømomformere og konvertere Harmoniske, transienter og belastninger i trefaset elforsyning Fejlfinding af DC til AC konvertere for defekte styrekredsløb eller udgangsfaser for IGBT gates Kabelinterface - test PWM-udgang for refleksioner og transienter Vpwm måling for at måle den effektive spænding på drevudgange Bestem V/Hz forholdet for at finde ud af, om det passer med motorens specifikationer. 100 Medfølgende tilbehør Fluke 190 serie II Instrumenter med fire kanaler indeholder et sæt med fire prober, ophængningsstrop, håndledsstrop, USB kabel med mini B stik, Litium-ion batteri med dobbelt kapacitet BP291, batterioplader/netadapter BC190, en FlukeView demopakke og brugermanualer på cd-rom. Modellerne med to kanaler leveres med to prober samt et sæt TL175 testledninger og et batteri med enkelt kapacitet BP290. 190-504 inkluderer også 4 stk. TRM50 koaksial terminator/ gennemgang og et batteri med dobbelt kapacitet BP291. Bestillingsinformation Fluke-190-504 Fluke-190-504/S Fluke-190-502 Fluke-190-502/S Fluke-190-204 Fluke-190-204/S Fluke-190-202 Fluke-190-202/S Fluke-190-104 Fluke-190-104/S Fluke-190-102 Fluke-190-102/S Fluke-190-062 Fluke-190-062/S Color ScopeMeter (500 MHz, 4-kanals) EAN: 0095969696326 Color ScopeMeter (500 MHz, 4-kanals), EAN: 0095969696340 Color ScopeMeter (500 MHz, 2-kanals) EAN: 0095969601702 Color ScopeMeter (500 MHz, 2-kanals), EAN: 0095969601771 Color ScopeMeter (200 MHz, 4-kanals) EAN: 0095969579919 Color ScopeMeter (200 MHz, 4-kanals), EAN: 0095969579988 Color ScopeMeter (200 MHz, 2-kanals) EAN: 0095969601559 Color ScopeMeter (200 MHz, 2-kanals), EAN: 0095969601634 Color ScopeMeter (100 MHz, 4-kanals) EAN: 0095969580052 Color ScopeMeter (100 MHz, 4-kanals), EAN: 0095969580120 Color ScopeMeter (100 MHz, 2-kanals) EAN: 0095969601412 Color ScopeMeter (100 MHz, 2-kanals), EAN: 0095969601481 Color ScopeMeter (60 MHz, 2-kanals) EAN: 0095969601276 Color ScopeMeter (60 MHz, 2-kanals), EAN: 0095969601344 Applikationerne bliver synlige med et enkelt tryk på en knap. Vpwm målinger Udgangssignalet fra en VFD er meget komplekst. Når Vpwmfunktionen vælges, skifter ScopeMeter et automatisk over til et dedikeret stykke software, som er i stand til at analysere kurveformen. Målinger af volt/hertz forholdet Outputdrejningsmomentet for en motor bestemmes på grundlag af forholdet mellem motorens tilførte spænding og frekvens, der er kendt som volt pr. hertz (V/Hz) forholdet. Hvis det rette forhold ikke opretholdes, vil det have indflydelse på motorens drejningsmoment, akslens hastighed og motorstøjen. Desuden vil motoren vil trække mere strøm, og det fører til en forhøjet temperatur. For at en motor kan producere sit nominelle moment ved variable hastigheder, er det også nødvendigt at styre den spænding og frekvens, som tilføres motoren. En VFD opretholder et forudindstillet V/Hz forhold, når der sendes strøm til en motor ved de variable hastigheder. Dette kritiske V/Hz forhold kan overvåges af en speciel funktion, som er en del af målingerne. Effektmålinger Med dagens udsving på elnettet er det vigtigt at få detaljerede oplysninger om parametre såsom effektfaktor, VA og VA reaktiv. Et ScopeMeter kan måle disse faktorer ved et tryk på knappen. Se alt ekstratilbehør til Fluke 190 serien på side 102

ScopeMeter 120-serien Tre-i-én enkelhed Fluke 124 Fluke 123 Den kompakte ScopeMeter 120-serie er den robuste løsning til industrielle fejlsøgnings og installationsanvendelser. Det er et komplet integreret testværktøj med oscilloskop, multimeter og papirløs skriver i ét økonomisk overkommeligt og brugervenligt instrument. Find de hurtige svar på problemerne i maskin-, instrumentations-, kontrol- og strømsystemer. 2-kanals, 40 MHz eller 20 MHz digitalt oscilloskop To 5.000-trins digitale Sand RMS multimetre En 2-kanals TrendPlot skriver Brugervenlig Connect-and-View trigger til håndfri betjening Bushelbredstest til industrielle bussystemer (Fluke 125) Skærmede testledninger til oscilloskop-, modstands- og gennemgangsmålinger Effektmålinger og måling af harmoniske (Fluke 125) Op til 7 timers drift på batteriet 600 V KAT III sikkerhedscertificeret Optisk isoleret interface til pc- og printertilslutning (ekstratilbehør) Robust, kompakt instrumenthus Brug TrendPlot til at hjælpe med at finde periodiske fejl hurtigt De sværeste fejl at finde er dem, der kun sker en gang imellem; periodiske fejl. De kan være forårsaget af dårlige forbindelser, støv, snavs, korrosion eller ganske enkelt knækkede ledninger eller stik. Du er der måske ikke og ser det - Fluke ScopeMeter er der. Med den papirløse skriverfunktion kan du plotte minimum og maksimum spidsværdier samt gennemsnitsværdi over tid - op til 22 dage (Fluke 190-serien) eller 16 dage (Fluke 120-serien). Bushelbredstilstand (Fluke 125) Bushelbredstilstand angiver, om de elektriske signaler på industrielle busser og netværk, som f.eks. CANbus, Profibus, RS-232 m.m., er gode eller dårlige. Fluke 125 validerer kvaliteten af de elektriske signaler, så snart der er passeret elektriske signaler gennem netværket. Sand RMS Connect-and-View trigning sørger øjeblikkeligt for et stabilt display Skopbrugere ved hvor vanskelig trigning kan være. Forkerte indstillinger giver ustabile og sommetider forkerte resultater. Flukes unikke Connectand-View genkender signalmønstre og indstiller automatisk til korrekt trigning. Den sørger for et stabilt, pålideligt og repetérbart billede af praktisk taget ethvert signal - inklusive motordrev og styresignaler - uden at røre en knap. Connect-and-View fanger selv de mest komplekse frekvensomformersignaler Medfølgende tilbehør PM8907 netadapter/lader, STL120-III skærmet testledningssæt(1 rød, 1 grå) inklusive krognæb; BB120 skærmet BNC adapter, BP120MH NiMH-batteri, VPS40-III spændingsprobe til bred båndbredde (Fluke 125/124); TL175 SafeGuard testledning, i400s strømtang (Fluke 125) Brugervejledningen Kom godt i gang Bestillingsoplysninger Fluke 123 Industrielt ScopeMeter (20 MHz) EAN: 0095969052313 Fluke 123/S Industrielt ScopeMeter (20 MHz) inklusive SCC120 tilbehørskit EAN: 0095969052320 Fluke 124 Industrielt ScopeMeter (40 MHz) EAN: 0095969234474 Fluke 124/S Industrielt ScopeMeter (40 MHz) inklusive SCC120 tilbehørskit EAN: 0095969234481 Fluke 125 Industrielt ScopeMeter (40 MHz) EAN: 0095969400947 Fluke 125/S Industrielt ScopeMeter (40 MHz) + SCC120-tilbehørssæt EAN: 0095969401029 Ekstratilbehør Fluke 120 serien AC120 Krokodillenæb BB120 Adapter BNC (hun) til skærmet bananstik BHT190 Bushelbredstest break-out adaptersæt BP120MH NiMH batteripakke med høj kapacitet C120 Beskyttende bæretaske i hårdt materiale C125 Beskyttende bæretaske C195 Beskyttende bæretaske HC120 Krognæb til STL120-III OC4USB Optisk isoleret interfacekabel til USB port PM8907 Netspændingsadapter og batterioplader PM8907/820 SMPS strømadapter og batterioplader PM9080/101 Optisk isoleret RS-232C interfaceadapter RS120-III Udskiftningssæt af probetilbehør SCC120 Software, kabel og bæretaskesæt SCC128 Automotivt tilbehørssæt STL90 Sæt af skærmede testledninger STL120-III Sæt af skærmede testledninger (forbedret sikkerhedsdesign) TP920 Testprobe adaptersæt SW90W FlukeView ScopeMeter software til Windows VPS40-III Spændingsprobesæt 101

Tilbehør til ScopeMeter TRM50 VPS410-II-X VPS420-X VPS510-X STL120-III VPS40-III ScopeMeter serie 190-serie II 120-serien Type tilbehør VPS410-X-II VPS420-X VPS510-X STL120-III VPS40-III Beskrivelse Spændingsprobe Spændingsprobe Spændingsprobe Skærmede testledninger Spændingsprobe Farve Rød, grå, blå, grøn Rød-Sort, Grå-Sort, Blå-Sort, Rød, grå, blå, grøn Rød + grå Sort Grøn-Sort Dæmpning 10:1 100:1 10:1 1:1 10:1 Båndbredde DC MHz 500 MHz 150 MHz 500 MHz 12,5 MHz 40 MHz Længde (m) 1,2 m 1,2 m 1,2 m 1,2 m 1,2 m Sikkerhedsklassificering KAT II -- -- -- 1000 V 1000 V Sikkerhedsklassificering KAT III 1000 V 1000 V* 300 V 600 V 600 V Sikkerhedsklassificering KAT IV 600 V 600 V* -- -- -- * Proben til høj arbejdsspænding er specificeret til arbejdsspænding (mellem probespids og referenceledning) op til 2000 V i KAT III eller 1200 V i KAT IV miljøer. Referenceledningsspænding (mellem referenceledning og jord): 1000 V i KAT III, 600 V i KAT IV. Disse specifikationer gælder kun ved brug sammen med testværktøjet i Fluke 190 II serien. VPS420 PM9091 / PM9092 PM9081 PM9082 PM9093 Beskrivelse PM9091 PM9092 PM9081 PM9082 PM9093 50 Ω BNC kabelsæt 3 x (rød, grå, sort) dobbelt bananstik han til hun BNC dobbelt bananstik hun til han BNC han BNC til dobbelt hun BNC han til hun BNC Længde 1,5 m 0,5 m -- -- -- Sikkerhedsklassificering CAT III 300 V EAN: 0095969022064 600 V EAN: 095969022071 600 V EAN: 0095969014922 600 V EAN: 0095969015011 10:1 EAN: 0095969022057 RS400 AS400 BP290 BP291 OC4USB EBC290 102 Ekstratilbehør Fluke 190 Serie-II AS400 Probeforlængersæt til i VPS400 serie spændingsprober BC190 Netspændingsadapter og batterioplader BC190/820 SMPS strømadapter og batterioplader BP290 Opladelig litium-ion batteripakke med enkelt kapacitet, 2400 mah BP291 Opladelig litium-ion batteripakke med dobbelt kapacitet, 4800 mah C195 Beskyttende bæretaske C290 Beskyttende bæretaske i hårdt materiale C437-II Beskyttende bæretaske i hårdt materiale med ruller EBC290 Ekstern batterioplader HC200 Udskiftningssæt til krognæb HH290 Ophængningskrog MA190 Tilbehørssæt til medicoteknisk anvendelse RS400 Probetilbehør udskiftningssæt til VPS400 serie spændingsprober RS500 Probetilbehør udskiftningssæt til VPS510 serie spændingsprober SCC290 Software og bæretaskesæt SCC298 Automotivt fejlfindingssæt til Fluke Serie-II SKMD-001 Værktøjssæt til motorer og drev SW90W FlukeView ScopeMeter software til Windows TL175 TwistGuard testledningssæt TRM50 Koaksial feed-through BNC han til BNC hun kabelterminator, 50 ohm VPS101 Dobbeltisoleret spændingsprobesæt, 1:1, 30 MHz, sort VPS220-X Spændingsprobesæt, 100:1, 200 MHz. X = Rød eller grå farve VPS410-II-X Spændingsprobesæt i industriel klasse, 10:1, 500 MHz. X= B(blå) eller G(grå) eller R(rød) eller V(grøn) farve VPS420-X Probe til høj arbejdsspænding, 100:1, 150 MHz. VPS510-X Kompakt probe med bred båndbredde til elektronikapplikationer, 10:1, 500 MHz, X= B(blå) eller G(grå) eller R(rød) eller V(grøn) farve

ScopeMeter bærbare oscilloskoper FlukeView ScopeMeter software til dokumentation, arkivering og analyse af kurveformer Få mere ud af dit ScopeMeter med FlukeView ScopeMeter SW90W software til Windows. Dokumentation af kurveformer, skærmbilleder og data ved hjælp af lagring på din pc til udskrivning eller til import som data i en rapport Tilføj tekst til ScopeMeter indstillingerne, så brugerne får vejledning, når indstillingerne kaldes frem Arkiver registreringerne for at oprette et bibliotek over kurveformer til nem reference, sammenligning af kurveformer eller bestået/ikke bestået test Analysér kurveformerne ved hjælp af markører Eksportér data til et andet analyseprogram Zoom-ind funktionalitet, der viser flere detaljer på kurveformen FlukeView tilbyder fjernstyring af ScopeMeter Online optagelse af din aktuelle kurveform Tag et snapshot af den aktuelle kurveform, og arkivér det som en BMP fil Konverter kurveformen til en FFT udlæsning for at se tilstedeværelsen af harmoniske svingninger Generelle ScopeMeter specifikationer Model 190-504 190-502 190-204 190-202 190-104 190-102 190-062 125 124 123 Specifikationer Båndbredde 500 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz Maks. samplinghastighed i realtid 5 GS/sek 2,5 GS/sek 1,25 GS/sek 625 MS/sek 25 MS/sek Indgangsfølsomhed 2 mv/div til 100 V/div, plus variabel attenuering 5 mv/div Maks. tidsbasehastighed 1 ns/div. 2 ns/div. 4 ns/div. 10 ns/div. 10 ns/div. 20 ns/div. Antal kanaler 4 2 4 2 4 2 2 2 Ekstern trigger Nej Ja Nej Ja Nej Ja Ja Ja Uafhængige flydende isolerede indgange (KAT klassificering) 1000 V KAT III, 600 V KAT IV Nej Maks. registreringslængde. I Scope funktion. I ScopeRecord funktion 10.000 samples pr. kanal 30.000 min./maks. par pr. kanal 512 min/maks. samples pr. kanal Glitch registrering 8 ns spidsdetektering ved fuldt tidsbaseområde 40 ns Indbygget sand RMS multimeter 5000 trin 5000 trin 5000 trin Dobbelt 5000 trin Dedikerede testegenskaber V/Hz forhold, mas, Wh, FFT Harmoniske -- Generelle specifikationer Netspændingsadapter/batterioplader inkluderet (typenummer) BC190 Netspændingsadapter/batterioplader PM8907 Netspændingsadapter/batterioplader Batteri inkluderet BP291 BP290 BP291 BP290 BP291 BP290 BP290 BP120MH Størrelse (mm) 265 x 190 x 70 232 x 115 x 50 Vægt (kg) 2,2 2,1 2,2 2,1 2,2 2,1 1,2 Sikkerhedscertificeret 1000 V KAT III / 600 V KAT IV 600 V KAT III 103