CTS - Climatic Test Cabinet Type C -40/350

Relaterede dokumenter
Citrotek EMC-Temperature Test Chambers (bench top version)

CTS-Temperature Test Chambers (Bench Top Version)

HIGH SPEED CORRODER HSC 512 HSC 512 (High Speed Corroder) is a salt spray test tool which accelerates corrosion on test specimens and surfaces.

Microsoft MB-330 Microsoft Dynamics 365 Unified Operations Core

CONTROL ONE OR MULTIPLE DOOR WITH MOBILE WEB APP CONTROL DOOR LOCK GATE BARRIER. Price list: Sample 99 EUR 10pcs 71 EUR 100pcs 49 EUR 1000pcs 36 EUR

GSM gate opener wireless remote control ON OFF switch free call mobile web app Price list: Sample 99 EUR 10pcs 71 EUR 100pcs 49 EUR 1000pcs 36 EUR

GSM DOOR CONTROLLER GATE OPENER ACCESS CONTROLL SYSTEM MOBILE WEB APP Price list: Sample 99 EUR 10pcs 71 EUR 100pcs 49 EUR 1000pcs 36 EUR

Hudevad P200. Technical datasheet

Original instructions Installation guide

Reference Number Description Part Number

Hudevad P5 Easy Clean

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

Video Projector Controller. Brugermanual

Setup Financial Ledger in Microsoft Dynamics AX 7. Case Study 3 Scenario

Slot diffusers. Slot diffusers LD-17, LD-18

WIO200A Water in oil sensor

CART MULTITEK CART MULTITEK CART. The MultiTek Cart

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove

Programmable pressure transmitters PTM

Parts List. Reference Number

AUTOCAD P&ID 2011 GETTING STARTED

Spare parts ASC 3500 G LE V6 SKU:

Technical Specifications

Engine Powered Forklift ton

ENHED VÆGT: Pos Vare Nr Vare betegnelse Enhed Antal TK/Thorus delivery level Stk Regulator for luft Stk 2

MS-H280-Pro Magnetic Stirrer

Spare parts ASC 3000 G V11 SKU:

ENHED VÆGT: Pos Vare Nr Vare betegnelse Enhed Antal TK/Thorus delivery level Stk Regulator for luft Stk 2

SkyVision Linear Installation manual, comfort _0216, Comfort, Item no Version 02/16

Navn: DVG V 560EC/F400 varenr.: 95135

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

Montage bjælkeklipper BM 5001R Art. No Assembly scythe mower BM 5001R Art. No

FREIGHTLINER. engine coolant reservoir. also available: COVERAGE FOR. Engine Coolant Reservoir. EGR Valve. EGR Cooler. Headlight Assembly

Spare parts ASC 5300 G V5

Navn: DVG V 450EC/F400 varenr.: 95257

Heating control system Price list: Sample 99 EUR 10pcs 71 EUR 100pcs 49 EUR 1000pcs 36 EUR

Spare parts ASC 3500 G V7 SKU:

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17

S M Illust.No. Part Name DENSO P/N Manu. P/N QTY I/C Start End Remarks

Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper

WI180C-PB. Online-datablad

Engine powered forklift tonne

Leverandør temadag. 2 November Dokumentation for drift af decentralt anlæg i regulerkraft. NET Selskab PBA EJER. Energinet.

Musikhuset Aarhus Lys/light

Family of R744 control valves and suggestions for efficient testing

Newton TS-51. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001

FilterMax DF. Modulopbygget støvopsamler

The size of the project.

HP Deskjet 3635 All-in-One - multifunction printer - color

Modulerende kuglehane

On-board emission measurements NO X. Erik Fridell

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL UNI-EL Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

MultiProgrammer Manual

talk outline sea bed network deployment issues; energy distribution seabed network issues;

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting

WT-1011RC Programmer User Guide

Fundamentals of HVAC Control Systems

Gateway MP til Modbus RTU. Alle BELIMO motorer med MP-Bus kan tilsluttes til MP-siden af UK24MOD. Interface MP / Modbus RTU

DESIGN COLLECTION COVER COUNTER SYSTEM

Vejledning til at tjekke om du har sat manuel IP på din computer.

Marine-Generator Prisliste 2011

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

RoE timestamp and presentation time in past

Beovox 5000 versions. Classic Audio Technical Information

Assembly Instructions. ROLZ-2 Portable AV/Conference Center

IPTV Box (MAG250/254) Bruger Manual

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Navn: DVG V 450EC/F400 varenr.: 95257

Ergonomisk løft. Specials. Højdestabler kasser High stacking boxes. Rulle løfter med 90º tilt Roll handling with 90º tilt

Nærskibsfart med bundlinieeffekt: Klima og miljø. Hans Otto Kristensen. Tlf: alt

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.

PMDK PC-Side Basic Function Reference (Version 1.0)

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

Delta Elektronik A/S - AKD

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

LED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit HOW CAN I UNDERSTAND THE FOLLOWING SHEETS?

Integrated Engine, Vehicle, and Underhood Model of a Light Duty Truck for VTM Analysis

Emergency ward simulation

MMS Multi Media Storage

Smart home system. Price list: Sample 99 EUR 10pcs 71 EUR 100pcs 49 EUR 1000pcs 36 EUR

Arki + welcome to a world of opportunities...

HP Officejet Pro 8218 Blækprinter

FilterMax F. Modulopbygget støvopsamler med integreret forudskiller

USER GUIDE Version 2.9. SATEL Configuration Manager. Setup and configuration program. for SATELLINE radio modem

Guiding philanthropy in support of the CFP

Navn: DVG V 355EC/F400 varenr.: 95256

Montage bjælkeklipper BM 870 III Art. No / BM 875 III Art. No

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

16. september 2013 InClimate funktionalitets og modbus setup version 7.1 Side 2

Index for chapter 10. Hooks f.pegboards and slatpanels double/single and accessories Page

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

WT-1011RC Programmer User Guide

Translucent multiwall polycarbonate corrugated

Plug Connectors for Food & Beverage

Montageanvisning Assembly instructions. MultiDicer KMD 12, 18

Switchmode rectifier. Type LEIF with PFC. »We store the world's energy« Network

Brinell Hardness Indentation Measurement System Operation Manual

Transkript:

CTS - Climatic Test Cabinet Type C -40/350 More information at https://www.cts-klimaskabe.dk Picture including options (e.g. door with window) C40_350_v2017_eng_.doc 18.01.2018 page 1 of 9 pages

CTS - Climatic Test Cabinet Type C -40/350 Your benefits: low power consumption, please see quotation text very low-noise level, only < 55 db(a) user-friendly and convenient handling and programming with the colour CTS-Multi-Touch panel or with the optional CID-Software on the PC uniform operation due to identical operating panel for all cabinets from bench top to walk-in chambers temperature measuring with PT 100 in air inlet and air outlet Included in basic equipment operating panel with high resolution colour LCD display for easy handling installed in the front of the cabinet defined keys for elementary functions of the cabinet such as start/stop, fixed-value/automatic operation, interruption, light, etc. error display in plain text potential-free contact for malfunction signal Ethernet - Interface 2 digital Out, potential-free, to switch test specimen ON/OFF adjustable software-temperature-limiter min./max. safety temperature limiter according DIN EN 14597 maintenance-free capacitive humidity measuring system level indicator for the humidification water reservoir in the display panel with warning message 1 x shelf, stainless steel, adjustable in height 1 x entry port 50 mm in the middle of test space on the right side door lockable; one-hand operation with integrated safety function to avoid unintentional closing international standards are fulfilled (CE-Conformity) C40_350_v2017_eng_.doc 18.01.2018 page 2 of 9 pages

Technical data Temperature tests: Temperature range Temperature fluctuation Temperature change rate according to IEC 60068-3-5 measured in air inlet Heat compensation -40 C to +180 C 0,3 K temporally heating: 3,5 K/min. cooling: 4,0 K/min. approx. max 3500 W at +20 C approx. max 2000 W at -20 C Climatic tests: Temperature range Temperature fluctuation Humidity range +10 C to +95 C 0,3 K temporally 10 % to 98 % rel. humidity Dew point range I + 7 C to +94 C Dew point range II -10 C to +7 C Humidity fluctuation Dew point range I Dew point range II Note: 1,5 % rel. humidity, temporally 3 % rel. humidity, temporally The deep dehu softkey must be activated to shift into dew point range II. As soon as the shift into dew point range II takes place, the water bath is emptied. At dew point <7 C, the set point only be achieved for a limited time, due to ice formation. The technical data, especially the performance data, refer to basic cabinet at an ambient temperature of +25 C, nominal voltage of 400V without test specimen, without radiation and without accessories or options, measured in the air inlet. Options can influence the technical data (e.g. entry port, door with window, notch, bursting disk, etc.) so that the end temperature, temperature change rate and at climate test cabinets the max. climate values could be reduced. Ambient conditions like temperature and sea level can also influence the performance data. C40_350_v2017_eng_.doc 18.01.2018 page 3 of 9 pages

Dimensions: Test space capacity 350 l Test space 650 x 720 x 750 mm (W x D x H) Overall dimensions see enclosed layout Weight approx. 600 kg net Data for installation and operation: Nominal voltage Nominal power Nominal current Connection Fuse (on site) 400 V +6/-10 %, 3/N/PE, 50 Hz 7 kw 12 A CEE 16 A 16 A time-lag Protection class IP 22 Power requirement cooling, max. 4,0 kw cooling, stabilized condition 2,0 kw heating, max. 3,9 kw heating, stabilized condition 1,0 kw climate, stabilized condition 3,3 kw humidification water Cooling water: Compressed air: Drain for condensate: consumption max. 1,5 l/h at max. humidification performance demineralized water conductivity max. 10 µs/cm ph-value 6 7 water has to be free of algae and pollution not necessary, or see options not necessary, or see options pressureless R ½, Note: A drain is required by site, also if the option automatic water replenishment is ordered Pressure equalisation: on top of the cabinet If there can be any emission from test specimen that will cause certain concentration and therefore unacceptable smell to the installation room, the exhausted air of the pressure compensator can be led out by a customer s exhaust air system with an open connection. The pressure equalizer must never be closed. C40_350_v2017_eng_.doc 18.01.2018 page 4 of 9 pages

Design: Test space stainless steel V2A, grade 1.4301 Shelf stainless steel V2A, grade 1.4301, 620 mm x 600 mm (W x D) max. load of each shelf 35 kg, max. load in total (max. number of shelves) 100 kg Floor load max. 150 kg/m 2 Air flow Heating/Cooling Climatic system Reservoir for humidification water Casing air inlet via air flow floor with a high air flow rate, air outlet at the rear wall of test space - heating by electrical resistant heaters, made of stainless steel, - mechanical cooling by direct evaporation in heat exchanger - water bath with permanent circulation and automatic water feed from supply tank. - dehumidification via condensation. Convenient filling from the front side galvanized steel, resistant powder coating Colour casing RAL 9006, white-aluminium decorative plates RAL 9007, grey-aluminium Door Refrigerating unit door can be opened completely hinged on left-hand side, one hand operation lockable air cooled, low noise refrigeration unit, continuous performance adjustment via electronic monitoring and control system, environmental friendly refrigerants R 452 A based on the current directives and regulations. Heat dissipation to the stabilized conditions approx. 3,0 kw installation room cooling max. approx. 7,0 kw Sound pressure level in accordance to DIN EN ISO 3744 < 55 db(a), measured in a distance of 1 metre from front Ambient conditions for operating: temperature: +15 C to +30 C rel. humidity: 20 % to 75 % rel. h. The room must be dry and ventilated. The floor has to be plane. Local laws and standards have to be considered by the customer. C40_350_v2017_eng_.doc 18.01.2018 page 5 of 9 pages

Control Functions - 32-bit controller - compatible for all CID-versions - external control by customer via ASCII protocol, identical for all CTS equipment - operating panel with glass surface, illuminated from the back - multi-gestures display for easy handling - big colour display with high resolution - customer specified favourite bar - handling via touch, slide and wipe gestures - error massage in plain text with report function - graphic curve progressions - possibility to connect a USB Stick for network independent backup of measurement data, which has to be opened via CID - software - easy input of test programs - graphic program preview Measurement sensor - temperature sensor PT 100, DIN EN 60751, class A - humidity sensor with capacitive humidity measuring system Malfunction signal supplied to potential-free contact max. load 30 V - DC, 2A Touch-Panel: C40_350_v2017_eng_.doc 18.01.2018 page 6 of 9 pages

Data Interfaces basic: Ethernet - Interface option: RS 485 - Interface USB Interface RS 232 - Interface With all interfaces customer has the possibility to control the cabinet via ASCII-protocol. This means simple commands for default and demand settings like set - and actual temperature, status information or to start and stop the cabinet. The Ethernet - Interface offers the possibility to integrate the cabinet in an onsite network and offers the additional opportunity to get status information via web browser. As an alternative the CTS-CID-Software for programming, controlling, measuring and visualization can be used to control the cabinet. The CID- license is available as an option. With the RS 485 - Interface customer can crosslink up to 32 cabinets over a long distance with a PC. The USB - Interface will be simulated as a virtual serial Interface on the PC by using the included driver. C40_350_v2017_eng_.doc 18.01.2018 page 7 of 9 pages

Note: Company-specific standards and norms are not considered. Clarifications with public authorities are on site. Costs are not included in the quotation. The installation cannot be used for tests on explosive, corrosive, toxic or easy inflammable materials or with specimens generating or releasing such materials. This applies particularly to all tests with liquids that boil easily, fuel, hydraulic fluids, lubricants, ammonia, etc. In this case, please pay attention to the information of the material safety data sheet. The operator has to check the material compatibility of the materials fitted in the testing room (stainless steel 1.4301, non-ferrous metals, aluminium, silicone) to the materials/gases which might be emitted by the test specimen. This can form acids or bases when exposed to humidity. The leaking materials/gases can lead to extensive damage of the equipment. CTS GmbH will not take responsibility (no warranty) for damages resulting of emission from toxic or aggressive substances from test specimen. The technical design of the unit with regards to basic security and health requirements refers to the following directives and standards: Directives and National Legislation Machinery directive 2006/42/EC Low-voltage directive 2014/35/EU EMC directive 2014/30/EU Pressure equipment directive 2014/68/EU Mechanical Standards EN ISO 13857 (issue 06/2008) EN 378-1,2,3,4 (issue 03/2017) DIN EN ISO 13732-1 (issue 12/2008) EN ISO 12100 (issue 03/2011) AD2000 (issue10/2000) Electrical Standards EN ISO 13849-1 (issue 12/2008) EN ISO 13849-2 (issue 02/2013) EN 61000-6-2 (issue 03/2006) EN 61000-6-3 (issue 09/2011) EN 61010-1 (issue 07/2011) EN 61010-2-010 (issue 06/2004) VDE 0100-410 (issue 06/2007) DGUV regulation 3 C40_350_v2017_eng_.doc 18.01.2018 page 8 of 9 pages

Layout of CTS-Cabinet, test space volume 350 l 1 Entry port Ø 50 mm 2 Control panel 3 Window 570 x 710 (option) 4 Electr. Connection cable, length 5 m 5 Pressure equalizer 6 Area for outlet of cooling air, both sides 7 Drain of test room R ½ 8 Water-inlet demi-water R ½ (option) 9 Cooling water connections R ¾ (option) 11 Main Switch 12 Control unit 13 Compressed air inlet, coupling with hose connection Ø 9 mm (option) 14 Cable entry for interface ports 15 Operating temperature limiter (option) * clearance width/high + entrance clearance C40_350_v2017_eng_.doc 18.01.2018 page 9 of 9 pages