TS400 Sine Wave Inverter. Owner s Guide

Størrelse: px
Starte visningen fra side:

Download "TS400 Sine Wave Inverter. Owner s Guide"

Transkript

1 TS400 Sine Wave Inverter Owner s Guide

2

3 TS400 Sine Wave Inverter Owner s Guide

4 $ERXW;DQWUH[ Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power. 7UDGHPDUNV TS400 Sine Wave Inverter is a trademark of Xantrex International. Xantrex is a registered trademark of Xantrex International. Other trademarks, registered trademarks, and product names are the property of their respective owners and are used herein for identification purposes only. 1RWLFHRI&RS\ULJKW TS400 Sine Wave Inverter Owner s Guide July 2003 Xantrex International. All rights reserved. 'LVFODLPHU UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. ( XANTREX ) (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK. 'DWHDQG5HYLVLRQ July 2003 Revision A 3DUW1XPEHU &RQWDFW,QIRUPDWLRQ Telephone: (toll free in North America) (direct) Fax: CustomerService@xantrex.com Web:

5 About This Guide Purpose The TS400 Sine Wave Inverter Owner s Guide contains information for installing, operating, and troubleshooting the TS400 Sine Wave Inverter (TS400). Scope This Guide provides safety guidelines, installation, operation, troubleshooting, and warranty information for the TS400. Basic information on battery types and sizes is provided in Appendix B, Battery Types and Sizes. For comprehensive information about your battery, refer to the battery manufacturer s guide. Service information is not included as the unit does not contain userserviceable parts. Audience This Guide is intended for anyone who needs to install and operate the TS400 Sine Wave Inverter. Installers should be certified technicians or electricians. Organization The Owner s Guide is organized into four chapters and two appendixes. Chapter 1, Introduction, outlines the main performance and safety features of the TS400. Reading this chapter will give you a clear understanding of the inverter s capabilities. Chapter 2, Installation, provides detailed information for installing the TS iii

6 About This Guide Chapter 3, Operation, provides information about operating the TS400. Details are provided on how to read the front panel indicators to monitor the TS400. Chapter 4, Troubleshooting, explains how to identify and solve problems that can occur with the TS400. Appendix A, Specifications, provides the electrical and physical specifications of the TS400. Appendix B, Battery Types and Sizes, provides information that will help you to select, connect, and maintain batteries that are most appropriate for your application. Warranty and Product Information, contains the product warranty, explains how to return a product for service, and describes how to prepare for a call to Xantrex Customer Service. Conventions Used The following conventions are used in this guide. WARNING Warnings identify conditions that could result in personal injury or loss of life. CAUTION Cautions identify conditions or practices that could result in damage to the TS400 Sine Wave Inverter or to other equipment. Note: Notes describe additional information which may add to your understanding of how to use the TS400. Important: These notes describe an important action item or an item that you must pay attention to. iv

7 Acronyms and Terminology About This Guide AC DC CSA FCC GFCI UL Hardwiring Alternating current Direct current Canadian Standards Association Federal Communications Commission Ground fault circuit interrupter Underwriters Laboratories Inc. to make a permanent electrical connection Related Information You can find more information about Xantrex Technology Inc. as well as its products and services at v

8 vi

9 Important Safety Instructions WARNING This Owner s Guide contains important safety and operating instructions. Before using your TS400 Sine Wave Inverter, be sure to read, understand, and save these safety instructions. WARNING: Restrictions on Use The TS400 Sine Wave Inverter shall not be used in connection with life support systems or other medical equipment or devices. General Precautions WARNING: Shock hazard The TS400 has On/Standby mode only. It does not have an Off mode, that is, DC power is permanently connected to the unit. 1. Before installing and using the inverter, read all appropriate sections of this guide and any cautionary markings on the inverter and the batteries. 2. Do not operate the inverter if it has received a sharp blow, been dropped, or otherwise damaged. If the unit is damaged, see Warranty and Product Information on page WA Do not dismantle the inverter; it contains no user-serviceable parts. Attempting to service the unit yourself could cause electrical shock or fire. Internal capacitors remain charged after all power is disconnected. See Warranty on page WA 1 for instructions on obtaining service vii

10 Important Safety Instructions 4. To reduce the risk of electrical shock, disconnect DC power from the inverter before working on any circuits connected to the inverter. Turning the On/Standby switch to Standby ( ) will not reduce this risk. 5. Protect the inverter from rain, snow, spray, and water. 6. To reduce the risk of overheating, keep the ventilation openings clear, and do not install the inverter in a compartment with limited airflow. Precautions When Working With Batteries WARNING: Explosion and Fire Hazard Explosive Gas Precautions 1. To reduce the risk of battery explosion, follow all instructions published by the battery manufacturer and the manufacturer of the equipment in which the battery is installed. 2. Make sure the area around the battery is well ventilated. 3. Never smoke or allow a spark or flame near the engine or batteries. 4. Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion. 1. Batteries generate explosive gases during normal operation. Be sure you follow all relevant instructions exactly before installing or using your inverter. 2. This equipment contains components which tend to produce arcs or sparks. To prevent fire or explosion, do not install the inverter in compartments containing batteries or flammable materials or in locations that require ignition-protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, as well as joints, fittings, or other connections between components of the fuel system. viii

11 FCC Information to the User Important Safety Instructions This Class B device complies with Part 15 of the FCC Rules and all requirements of the Canadian Interference-Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation ix

12 x

13 Contents Important Safety Instructions General Precautions vii Precautions When Working With Batteries viii Explosive Gas Precautions viii FCC Information to the User ix 1 Introduction How TS400 Works Premium Power and Ease of Use Comprehensive Protection TS400 Features Front Panel Back Panel Optional Accessory: Remote Switch Dimensions of Remote Switch Part number of Remote Switch Installation Introduction Preparing for Installation Installation Codes Materials List Installation Tools and Materials Installing the TS Overview Step 1: Designing Your Installation Step 2: Mounting Your Inverter Step 3: Connecting the Chassis Ground Step 4: Installing the Optional S400 Remote Switch Step 5: Getting Ready to Connect the DC Cables Step 6: Routing the DC Cables Step 7: Connecting the DC Cables Step 8: Connecting Your Equipment to the GFCI Outlets Step 9: Hardwiring the AC Output Step 10: Performing Checks Prior to Initial Start-up Step 11: Testing Your Installation xi

14 Contents 3 Operation Front Panel Features Operating the TS Turning the TS400 On Turning the TS400 to Standby When Not in Use Using the Optional S400 Remote Switch Recharging Your Batteries Recovering from Low Battery Voltage Shutdown Restarting or Operating Multiple Pieces of Equipment Monitoring the Operating Status Resetting After a Fault or Shutdown Troubleshooting Troubleshooting Reference A B Specifications Electrical Specifications A 2 Physical Specifications with Projections A 2 Regulatory Approvals A 3 Fan Cooling System A 3 Battery Types and Sizes Battery Types B 2 Automotive Starting Batteries B 2 Deep-Cycle Batteries B 2 Battery Size B 3 Estimating Battery Requirements B 4 Battery Sizing Example B 4 Battery Sizing Worksheet B 5 Using Multiple Batteries B 6 Two Batteries Connected In Parallel B 6 Two Separate Battery Banks B 6 Battery Tips B 7 Warranty and Product Information WA 1 Warranty WA 1 Disclaimer WA 2 Product WA 2 xii

15 Contents Exclusions WA 2 Warning: Limitations On Use WA 2 Return Material Authorization Policy WA 3 Return Procedure WA 3 Out of Warranty Service WA 3 Information About Your System WA 4 Index IX xiii

16 xiv

17 Introduction Congratulations on your purchase of the Xantrex TS400 Sine Wave Inverter! The TS400 has been designed to give you premium power, ease of use, and outstanding reliability. Please read this chapter to familiarize yourself with the main performance and protection features of the TS400. To ensure quality customer service for your inverter, be sure to keep your proof of purchase. Also, take a few minutes at this time to complete the form, Information About Your System on page WA 4.

18 Introduction How TS400 Works TS400 is a sine wave inverter which converts 12 volts direct-current (DC) power from your battery to 120 volts alternating current (AC) power. This AC power is the same as the electricity you get from your utility. In terms of output, TS400 provides 400 watts of sine wave power for operating your equipment. Premium Power and Ease of Use TS400 provides premium power for your portable power needs. The inverter s sine wave output provides clean power for small power tools, test equipment, television monitors and battery chargers. Superior features and rugged durability have been combined with ease of use: 400 watt inverter with 800 watt surge Filtered sine wave output will not cause distortion on sensitive electronics DSP control technology starts complex loads with ease Two GFCI outlets and hardwire AC connections Easy-to-read indicator lights on the front panel Optional S400 Remote Switch provides On/Standby control from a convenient location Audible alarm for low battery voltage Automatic cooling fan

19 Comprehensive Protection Comprehensive Protection TS400 is designed to meet UL 458 and CSA C22.2 No safety standards and it is compliant with FCC Class B. TS400 comes equipped with numerous protection features to guarantee you safe and worry-free operation. 3URWHFWLRQIHDWXUH Low voltage alarm and shutdown High voltage shutdown Over-temperature shutdown Overload protection Supplemental circuit protection Short circuit protection Ground fault circuit interrupter (GFCI) 7KLVSURWHFWLRQIHDWXUH«Protects the battery from becoming completely discharged. The Low Battery light and audible alarm indicate that input voltage is low (10.7 volts). If the input voltage drops below 10.3 volts, the TS400 shuts down automatically and the Inverter ON light turns off. The TS400 recovers automatically when the input voltage comes up to about 12.6 volts. Protects the TS400 by disabling the AC output when the input voltage rises to 15.3 volts or more. The AC output is enabled when the input voltage drops to 14.5 volts. Disables the AC output of the TS400 when the internal temperature rises to unacceptable levels due to higher ambient temperature or overloading. The TS400 recovers automatically when it cools down. Disables the AC output of the TS400 if the appliance connected to the inverter exceeds the 400 watt rating of the inverter. The TS400 will have to be reset. (See Resetting After a Fault or Shutdown on page 3 7.) Trips and disables the AC output when a current in excess of 7.5 amps is drawn from the TS400. The supplemental circuit protector can be reset to enable the unit to operate again after clearing the overload condition. (See Resetting After a Fault or Shutdown on page 3 7.) Disables the AC output of the TS400 when a short circuit is applied on the AC output. Once the short circuit is cleared, the TS400 will have to be reset. (See Resetting After a Fault or Shutdown on page 3 7.) Trips and disables the output of the TS400 when a ground fault current is detected. The output can be enabled again by resetting the GFCI, once the ground fault is cleared. (See Ground Fault on page 3 7.)

20 Introduction TS400 Features Front Panel Figure 1-1 Front Panel of the TS400 \ Table 1-1 Front Panel Features )HDWXUH 'HVFULSWLRQ 1 On/Standby Switch turns the inverter to On ( ) or to Standby ( ). 2 Inverter ON light illuminates when the TS400 is powering equipment from the battery. 3 Low Battery light illuminates when your battery voltage is lower than 10.7 volts. 4 Fault light illuminates for fault conditions such as over temperature, output overload, or battery over voltage. 5 Supplemental Circuit Protection button trips if there is an overcurrent (over 7.5 amps) or a short circuit. 6 GFCI outlets for connecting your equipment. 7 Ventilation openings provide air circulation for peak performance

21 Back Panel TS400 Features Figure 1-2 Back Panel of the TS400 Table 1-2 Back Panel Features )HDWXUH 'HVFULSWLRQ 1 DC terminal, negative 2 DC terminal, positive 3 Wiring box access panel (For a view with the panel removed, see Completing the Hardwiring on page 2 21.) 4 Knockout for AC output hardwiring 5 Chassis ground lug 6 Jack for optional remote switch 7 Mounting flanges 8 Ventilation openings provide air circulation

22 Introduction Optional Accessory: Remote Switch Dimensions of Remote Switch An optional remote switch can be plugged into the remote switch jack at the back of the TS400. It lets you switch the TS400 from on to standby from a convenient location up to 25 feet (7.5 m) away from the inverter (using the cable supplied with the switch). +HLJKW :LGWK 'HSWK 2.5 inches (63.5 mm) 2 inches (50.8 mm) 1.1 inches (28.3 mm) &DEOHOHQJWK 25 feet (7.5 m) Part number of Remote Switch To purchase a remote switch, please contact Customer Service for a referral to a distributor. Please provide the part number See page ii for contact information. Note: The remote switch jack at the back of the TS400 may not be accessible once the inverter has been mounted. If you intend to use the remote switch with an TS400 that has already been installed, consult a qualified service technician before installing and connecting the remote switch

23 Installation Chapter 2, Installation, provides detailed information for installing the TS400 and the optional S400 Remote Switch. This chapter provides: a system diagram safety instructions and installation codes that must be observed during installation a list of installation tools and materials detailed installation procedures chassis ground and DC cabling information procedures for hardwiring the AC output an illustration of inverter dimensions CAUTION Be sure to read all instructions before installing and operating the TS400.

24 Inverter ON Installation Introduction The system diagram shown in Figure 2-1 is the basic installation. Review this diagram carefully before installing the TS400. GFCI OUTLET GFCI OUTLET AC HARDWIRING ADDITIONAL LOADS INVERTER AC OUTLETS DC FUSE AND DISCONNECT OR DC CIRCUIT BREAKER S400 REMOTE SWITCH (OPTIONAL) TS400 Configuration BATTERY (S) Figure 2-1 System Diagram

25 Preparing for Installation Preparing for Installation Read this entire installation chapter so you can plan the installation from beginning to end. Prior to beginning your installation, review the Important Safety Instructions on page vii. WARNING: Electrical shock and fire hazards Xantrex recommends all wiring be done by qualified personnel. Disconnect all power sources to prevent accidental shock. Disable and secure all disconnect devices and automatic generator starting devices. It is the installer s responsibility to ensure compliance with all applicable installation codes and regulations. WARNING: Fire hazard To meet regulatory requirements, the TS400 must be mounted on a flat horizontal surface with the front panel in the upright position. Installation Codes It is the installer s responsibility to determine which codes apply and to ensure that all applicable installation requirements are met. Applicable installation codes vary depending on the specific location and application of the installation. Some examples are: The U.S. National Electrical Code (NEC) The Canadian Electrical Code (CEC) Canadian Standards Association (CSA), and RV Industry Association (RVIA) requirements for installation in RVs. WARNING: Restrictions on use The TS400 Sine Wave Inverter shall not be used in connection with life support systems or other medical equipment or devices

26 Installation Materials List Your TS400 Sine Wave Inverter package includes: One TS400 Sine Wave Inverter TS400 Sine Wave Inverter Owner s Guide After you unpack your TS400, be sure to record the product information in the form Information About Your System on page WA 4. If any of these materials are missing or unsatisfactory, please contact Customer Service. Telephone (toll free in North America) (direct) Fax Web CustomerService@xantrex.com Installation Tools and Materials Tools You will need the following tools and materials to install the TS400 and the optional S400 Remote Switch: To install the TS400, you need: Phillips screwdriver: #2 Slot screwdrivers: 1/8 inch and 1/4 inch Wrench for DC terminals: 10 mm or adjustable Wire stripper To install the optional S400 Remote Switch, you need: Power drill with 1/8-inch bit Jigsaw (optional) Feed wire (optional) Materials for TS400 and Optional S400 Remote Switch To install the TS400 and optional S400 Remote Switch, you require: DC cables (See Table 2-1 on page 2 9.)

27 Preparing for Installation Appropriately sized connectors. Two DC connectors suitable for ¼ inch (6 mm) that go on the DC input cable terminals. The other cable connectors will depend on your installation. Crimping tool for fastening lugs and terminals on DC cables (You may find it more convenient to have the crimp connectors attached by the company that sells you the cable.) DC fuse and Disconnect or DC circuit breaker (See page 2 9.) Four #10 hardware fasteners to mount the TS400 Four #6 self-tapping screws to mount the S400 Remote Switch Materials for AC output hardwiring Cable requirements: within the range of No. 14 to No. 18 AWG (minimum size) 3 conductors solid or stranded 1/2 inch cable clamp

28 Installation Installing the TS400 Overview This chapter provides detailed information on installing the TS400. The overall procedure is divided into 11 steps: 1. Designing your installation (page 2 6) 2. Mounting your inverter (page 2 10) 3. Connecting the chassis ground (page 2 11) 4. Installing the optional S400 Remote Switch (page 2 12) 5. Getting ready to connect the DC cables (page 2 14) 6. Routing the DC cables (page 2 15) 7. Connecting the DC cables (page 2 16) 8. Connecting your equipment to the GFCI outlets (page 2 18) 9. Hardwiring the AC output (page 2 19) 10. Performing checks prior to initial start-up (page 2 22) 11. Testing your installation (page 2 22) Step 1: Designing Your Installation Installation Codes Before doing anything else, you need to determine how you are going to use your TS400, and then design a power system that will give you maximum performance. The more thorough your planning, the better your power needs will be met. In particular, you will need to: Be aware of installation codes Choose an appropriate location Calculate your battery requirements and appropriate battery size Calculate the DC cable size Select the correct DC fuse and Disconnect or the DC circuit breaker See Installation Codes on page 2 3 for more information

29 Choosing a Location Installing the TS400 WARNING: Risk of fire or explosion This equipment contains components that could produce arcs or sparks. To reduce the risk of fire or explosion, do not install this equipment in compartments containing batteries or flammable materials, or in locations that require ignition-protected equipment. This includes any space containing gasolinepowered machinery, fuel tanks, or joints, fittings, or other connections between components of the fuel system. WARNING: Fire hazard Do not cover or obstruct the ventilation openings. Do not install this equipment in a compartment with limited airflow. Overheating may result. : The inverter should only be installed in a location that meets the following requirements: Dry Cool Ventilated Safe Choose a dry location. Do not allow water or other fluids to drip or splash on the inverter. Do not expose to rain, snow or splashing water. Normal air temperature should be between 32 F (0 C) and 104 F (40 C) the cooler the better within this range. The inverter requires air circulation to maintain optimum operating temperature and provide best performance. If the unit has inadequate ventilation, it may shut down due to overheating. Allow as much space around the ventilation openings as possible. Xantrex recommends that other objects be at least 3 inches (76 mm) away from the ventilation openings for best performance. The air vented through the openings should also have a path to circulate away from the inverter. Do not install the inverter in the same compartment as batteries or in any compartment containing flammable liquids like gasoline

30 Installation Close to battery compartment Protected from battery acid and gases Orientation Long DC cables must be very large (and expensive), so they should be kept short (see Table 2-1 on page 2 9). However, the unit should NOT be installed in the battery compartment due to the possible presence of explosive hydrogen gas from the batteries. Never allow battery acid to drip on the inverter or its wiring when filling the batteries or reading their specific gravity. Do not mount the unit where it will be exposed to gases produced by the batteries. These gases are corrosive and prolonged exposure will damage the inverter. To meet regulatory requirements, the TS400 must be mounted on a flat horizontal surface with the front panel in the upright position. Battery Requirements CAUTION The TS400 Sine Wave Inverter must only be connected to batteries with a nominal output voltage of 12 volts. The TS400 Sine Wave Inverter will not operate from a 6 volt battery and will be damaged if connected to a 24 volt battery. The batteries that you use strongly affect the performance of the TS400. It is important to connect the inverter to the correct size and type of battery. See Appendix B, Battery Types and Sizes on page B 1 for more information

31 DC Cables Installing the TS400 For the best load starting performance, the DC cables should be as short and large as possible. See Table 2-1 for minimum recommended cable size. Using a smaller cable may cause the inverter to shut down under heavy load. A larger cable may be used. Table 2-1 Minimum Recommended DC Input Cable (copper) AWG &DEOH/HQJWK%DWWHU\WR,QYHUWHU HDFKFDEOH 0LQLPXP5HFRPPHQGHG &DEOH6L]H³$:* 0 10 feet (0 3 meters) No feet (3 4.5 meters) No feet (4.5 9 meters) No feet (9 12 meters) No. 0 DC Fuse and Disconnect or DC Circuit Breaker If you are using a DC fuse and Disconnect, a maximum 80 amp Class T fuse shall be used for the DC fuse. A fuse of lower rating can be used, but it shall not be lower than 60 amp Class T. The Disconnect shall be rated at least 50 amps. Additionally, a DC circuit breaker rated 50 amps can be used

32 Installation Step 2: Mounting Your Inverter Mount your inverter before you connect any wires or cables. For your convenience, the inverter dimensions are provided in Figure 2-9 on page WARNING: Fire hazard To meet regulatory requirements, the TS400 must be mounted on a flat horizontal surface with the front panel in the upright position. To mount your TS400: 1. Turn the On/Standby switch on the front panel of the inverter to Standby ( ) position. 2. Select an appropriate mounting location and orientation. See Choosing a Location on page Hold the inverter against the mounting surface, mark the position of the mounting screws, and then remove the inverter. OR Use Inverter Dimensions on page 2 23 to mark the position of the mounting screws. You can also download a full-scale version of the mounting template from 4. Pilot drill the four mounting holes. 5. Fasten the inverter to the mounting surface with four #10 hardware fasteners

33 Step 3: Connecting the Chassis Ground Installing the TS400 The chassis ground lug is used to connect the chassis of the inverter to your system s chassis grounding point, as required by installation codes. Use copper cable that is either bare or provided with green insulation. Do not use the chassis ground lug for your AC output grounding wire. To connect the chassis ground: Refer to Figure Using the 1/4 inch slot screwdriver, loosen the screw on the chassis ground lug. 2. Connect a No. 8 AWG copper cable between the inverter s chassis ground lug and the DC grounding point for your system. In an RV or vehicle installation, this will usually be the vehicle chassis or a dedicated chassis ground bus. 3. Tighten the screw to a torque of 6 7 lbf-in ( Nm). Figure 2-2 Connecting the Chassis Ground

34 Installation Step 4: Installing the Optional S400 Remote Switch WARNING: Shock hazard Before making an opening in a wall, bulkhead or panel, ensure there is no wiring or other obstruction within the wall. WARNING: Shock hazard Ensure both the S400 Remote Switch and the TS400 are in Standby ( ) mode before installing. Installing the S400 Remote Switch (Xantrex product number ) is optional. The TS400 operates normally without the remote switch. The S400 Remote Switch is designed to be flush mounted on a wall, bulkhead or panel. A 25 foot (7.5 meter) telephone cable is supplied with the remote switch. If you want to extend the cable, use a high quality, 4-wire telephone extension cable with 6-position, 4-contact connectors. The maximum recommended cable length is 50 feet (15 meters). For your convenience, a full-scale mounting template is provided on page Note: The S400 Remote Switch connects to a jack at the back of the inverter. See System Diagram on page 2 2. To install the remote switch: 1. Choose a location that is dry, free from corrosive or explosive fumes, and otherwise appropriate for installing an electronic device. 2. Using the template, pilot-drill the mounting holes. Cut an opening about 2 inches x 1.2 inches (50 mm x 30 mm) and 1.4 inches (35 mm) deep. 3. Route the telephone cable inside the wall and through the opening to the inverter

35 Installing the TS Connect one end of the telephone cable to the back of the inverter as shown in Figure 2-3. Figure 2-3 Connecting Cable to the TS Connect the other end of the telephone cable to the remote switch as shown in Figure 2-4. Figure 2-4 Connecting Cable to the S400 Remote Switch 6. Place the remote switch in the opening and secure it with the four #6 fasteners

36 Installation Step 5: Getting Ready to Connect the DC Cables The DC cables should be as short as possible and large enough to handle the required current, in accordance with the electrical codes or regulations applicable to your installation. The minimum recommended DC cable size is specified in Table 2-1 on page 2 9. For the recommended DC fuse and Disconnect or DC circuit breaker, see page 2 9. To prepare the DC cables: Refer to Figure 2-5, Connection Order for DC Cables on page Cut the negative cable to the recommended length. (See Table 2-1 on page 2 9 for DC cable size.) Strip off enough insulation so you can install the terminal you will be using. Xantrex recommends the use of crimp connectors such as a ring lug type. The connector should be designed for a 6 mm or 1/4 inch stud size to connect to the TS400 Sine Wave Inverter. If a crimp connector is used, it should be crimped using the tool indicated by the connector manufacturer. 2. Cut two lengths of positive cable. One cable (maximum 18 inches) goes from the battery to the DC fuse and Disconnect or to the DC circuit breaker. The other cable goes from the DC fuse and Disconnect or to the DC circuit breaker to the positive DC terminal. 3. Attach the connectors to the ends of both cables. Make sure no stray wire strands protrude from the terminals

37 Step 6: Routing the DC Cables Installing the TS400 WARNING: Fire and shock hazard Route the cables away from sharp edges which might damage the insulation. Avoid sharp bends in the cable. Guidelines for Routing the DC Cables Do not attempt to use the chassis in place of the battery negative connection for grounding. The inverter requires a reliable return path directly to the battery. To reduce the chance of interference, keep the positive and negative cables close together ideally, tied together at regular intervals as shown in Figure 2-5, Connection Order for DC Cables on page To ensure maximum performance from the inverter, do not route your DC cables through a DC distribution panel, battery isolator, or other device that will cause additional voltage drops. The exception is the DC fuse and Disconnect or the DC circuit breaker which is required to protect the DC wiring

38 Installation Step 7: Connecting the DC Cables Battery Inverter 1 Figure 2-5 Connection Order for DC Cables CAUTION: Reverse polarity Before making the final DC connection, check cable polarity at both the battery and the inverter. Positive (+) must be connected to positive (+); negative ( ) must be connected to negative ( ). Reversing the positive (+) and negative ( ) battery cables will damage the inverter and void your warranty. WARNING: Fire hazard Use only appropriately sized copper cable. Make sure all DC connections are tightened to a torque of lbf-ft ( Nm). Loose connections will overheat

39 Installing the TS400 To connect the DC cables: Connect the DC cables as shown in Figure 2-5, in the order shown by the numbers. 1. Switch the On/Standby switch to the Standby ( ) position. 2. Route the DC cables from the battery bank to the inverter. See Step 6: Routing the DC Cables on page Install a DC fuse and Disconnect or a DC circuit breaker in the positive side of the circuit within 18 inches of the battery. This protects your battery and wiring in case of accidental shorting. (See DC Fuse and Disconnect or DC Circuit Breaker on page 2 9 for recommended fuse size and type.) Open the DC fuse and Disconnect or turn off the DC circuit breaker. 4. Connect one connector on the POSITIVE (+) cable to the POSITIVE DC terminal on the inverter. Tighten the nut to a torque of lbf-ft ( Nm). 5. Connect the other connector to the positive (+) terminal DC fuse and Disconnect or to the DC circuit breaker. Use a wrench to tighten the connection according to the manufacturer s recommendations. Test that the cable is secure. 6. Attach a short DC cable from the unconnected end of the DC fuse and Disconnect or DC circuit breaker. Tighten appropriately. 7. Observing polarity carefully, connect the other end of the fused cable to the POSITIVE (+) terminal of the battery. Tighten this connection to the battery manufacturer s recommended torque. 8. Connect one connector on the NEGATIVE ( ) cable to the NEGATIVE ( ) battery terminal. Tighten the connection according to the battery manufacturer s recommended torque. 9. Check that the polarity of the DC connections is correct: positive (+) on the inverter is connected to the positive (+) on the battery, and negative ( ) is connected to the negative ( ). 10. Connect the other connector of the NEGATIVE ( ) cable onto the NEGATIVE ( ) terminal on the TS400 Sine Wave Inverter. 11. Use a wrench to tighten the nut to a torque of lbf-ft ( Nm). Test that the cable is secure

40 Installation Step 8: Connecting Your Equipment to the GFCI Outlets To connect your AC equipment to the GFCI outlets: 1. Turn the inverter s On/Standby switch to Standby ( ). 2. Turn your AC equipment off. 3. Connect your AC equipment to the GFCI outlets in the front panel. 4. If you wish to connect more equipment, use a multiple-outlet extension cord. Ensure that the total power drawn does not exceed 400 watts. Note: Ensure that the Reset button on the GFCI outlets is not tripped. Important: If you have more permanent loads to connect to the inverter, Xantrex recommends that they be hardwired. See Step 9: Hardwiring the AC Output on page

41 Step 9: Hardwiring the AC Output Installing the TS400 If you wish to permanently connect additional AC outlets, Xantrex recommends hardwiring the AC output connections. WARNING: Fire, shock, and energy hazards Make sure wiring is disconnected from all electrical sources before handling. All wiring must be done in accordance with local and national electrical wiring codes. Do not connect the output leads of the inverter to any incoming AC source. To hardwire the AC output connections: 1. Turn the On/Standby switch to Standby ( ). 2. Remove the knockout using a slot screwdriver as shown in Figure 2-6. Do not leave the knockout inside the wiring box. Figure 2-6 Removing the Knockout

42 Installation 3. Locate the wiring box access panel, and remove the three screws to access the wiring box as shown in Figure 2-7. Figure 2-7 Removing the 3 Screws on the Wiring Box Access Panel 4. Remove the wiring box access panel from the unit. 5. Install a 1/2 inch cable clamp. 6. Locate the terminal block. The three terminals are labelled as follows: L Line N Neutral Ground 7. Strip about 2 inches (50 mm) off the jacket of the AC output cable. The AC output cable must be either solid or stranded, within the range of No. 14 to No. 18 AWG, and have three conductors. 8. Strip approximately 3/8 inch (10 mm) off the insulation of the cable. 9. Run the AC cable through the cable clamp and into the wiring box. 10. Using the 1/8 inch slot screwdriver, loosen the wire attachment screws on the terminals by five turns. 11. Insert and fasten the Ground wire into the corresponding terminal. 12. Insert the Line and Neutral wires into the corresponding terminals

43 Installing the TS Tighten the wire attachment screws to a torque of lbf-ft ( Nm) as shown in Figure 2-8. Leave some slack inside the output wiring box. 14. Secure the cable clamp on the cable jacket. 15. Attach the wiring box access panel and tighten the three screws. Figure 2-8 Completing the Hardwiring

44 Installation Step 10: Performing Checks Prior to Initial Start-up Before starting up your inverter, ensure these conditions are met: Chassis ground is properly installed On/Standby switch is in the Standby ( ) position on the TS400 Positive (+) battery cable is connected to the positive (+) battery terminal through the DC fuse and Disconnect or DC circuit breaker Negative ( ) battery cable is connected to the negative ( ) battery terminal Battery voltage is within the proper range for this unit ( volts DC) DC Fuse is intact (not blown) Step 11: Testing Your Installation WARNING: Shock hazard The On/Standby switch on the TS400 does not disconnect DC power to the TS400. When you are ready to test your installation and operate the TS400, close the DC fuse and Disconnect or the DC circuit breaker to supply DC power to the TS400. To test the TS400: 1. Turn the inverter s On/Standby switch to the On ( ) position. If the optional S400 Remote Switch is installed, turn the On/Standby switch on the remote switch to the On ( ) position. The green Inverter ON indicator illuminates. 2. Plug an appliance of 400 watts or less into one of the GFCI outlets. 3. Turn the appliance on to verify that it operates. 4. If the appliance operates, your installation is successful. 5. If the red Fault light illuminates, see Troubleshooting on page

45 Installing the TS400 T 5 Figure 2-9 Inverter Dimensions This drawing is not to scale. A full-scale mounting template is available at

46 Installation CUTOUT PANEL 2" X 1.2" (50.8 X 30.5) (DASHED LINE) DRILL Ø0.125 (1/8") HOLE 4 PLACES FOR #6/32 SELF TAPPING SCREW 2.5" (63.5) 2.1" (53.5) 0.2" TYP (5.0) Inverter ON 0.2" TYP (5.0) 1.6" (40.8) 2" (50.8) 1.1" (28.3) Figure 2-10 S400 Remote Switch Mounting Template (Scale approximately 1:1)

47 Operation Chapter 3, Operation explains how to use your TS400 effectively. This chapter explains how to turn the TS400 to On () or Standby ( ) from the front panel or from the optional S400 Remote Switch, monitor the status of the TS400, and reset the inverter. CAUTION Read this chapter before operating the TS400 Sine Wave Inverter. WARNING: Restrictions on use The TS400 Sine Wave Inverter shall not be used in connection with life support systems or other medical equipment or devices.

48 Operation Front Panel Features Before you begin to operate the TS400, review the front panel features in Figure 3-1. For a detailed description of each of the different features, see Front Panel of the TS400 on page 1 4 in the Introduction chapter Figure 3-1 Front Panel of the TS400 \ Table 3-1 Front Panel Features )HDWXUH 'HVFULSWLRQ 1 On/Standby Switch 2 Inverter ON light 3 Low Battery light 4 Fault light 5 Supplemental Circuit Protection button 6 Two GFCI outlets 7 Ventilation openings

49 Operating the TS400 Operating the TS400 On/Standby switch You can turn the TS400 to On ( ) or to Standby ( ) using the On/Standby switch (see Front Panel of the TS400 on page 3 2). Optional remote switch Resetting the TS400 Turning the TS400 On WARNING: Shock hazard If you have installed the optional S400 Remote Switch, you can also use the remote switch to turn the TS400 to On () or to Standby ( ). See Using the Optional S400 Remote Switch on page 3 4. The On/Standby switch on the TS400 or the S400 Remote Switch is also used to reset the TS400 after a Fault condition. See Resetting After a Fault or Shutdown on page 3 7. When the On/Standby switch is turned to On (), the TS400 powers your equipment using energy from the battery. To turn the TS400 on: 1. Turn the On/Standby switch on the TS400 to the On () position. The Inverter ON light illuminates on the TS400. AND If you have installed the S400 Remote Switch, turn the S400 Remote Switch to On (). 2. Operate your equipment. Turning the TS400 to Standby When Not in Use The TS400 has On mode and Standby mode only. It does not have an Off mode, that is, DC power is permanently connected to the unit. When you are not using the TS400 and want to conserve battery power, turn the inverter s On/Standby switch to the Standby ( ) position. To turn the TS400 to standby: 1. Turn your equipment off. 2. Turn the On/Standby switch on the TS400 or the optional S400 Remote Switch to the Standby ( ) position. The Inverter ON light turns off. With the On/Standby switch in Standby ( ) position, the TS400 draws no current from the battery

50 Operation If the On/Standby switch on the TS400 is in the On () position and the optional S400 Remote Switch is in the Standby ( ) position (see Important on page 3 4), the TS400 draws very little current (about 1 ma) from the battery. Using the Optional S400 Remote Switch The S400 Remote Switch performs the same function as the On/Standby switch on the TS400. Important: For the Remote Switch to function, the On/Standby switch on the TS400 must be turned to the On ( ) position. Purpose The S400 Remote Switch provides On/Standby control of the TS400 from a convenient location of up to 25 feet (7.5 meters) away using the supplied telephone cable. Cable length You can use a longer cable up to a maximum recommended length of 50 feet (15 meters). Xantrex recommends using a high quality 4-wire telephone cable wth 6-position, 4-contact connectors. Inverter ON Figure 3-2 S400 Remote Switch

51 Recharging Your Batteries Recharging Your Batteries Low Battery light Importance of recharging More information If the Low Battery light illuminates on the TS400 and you hear the low battery alarm, your battery level is low (less than 10.7 volts). As long as the Inverter ON light is illuminated on the TS400, the unit will continue to supply inverter power to your equipment. However, Xantrex highly recommends that you recharge your battery. Turn off your equipment and recharge your battery. When the Low Battery light and the audible alarm turn off (at 12.6 volts), you can restart your equipment. See Restarting or Operating Multiple Pieces of Equipment. Xantrex recommends that you recharge your batteries before they are 50% discharged. This gives them a much longer life cycle than recharging them when they are almost completely discharged. See Battery State of Charge on page B 8. For more information about battery chargers and battery monitors, see the Xantrex web site at Recovering from Low Battery Voltage Shutdown If the Low Battery light illuminates, you hear an alarm, and the Inverter ON light on the front panel turns off when you are operating the unit, the TS400 has shut down due to low battery voltage (10.3 volts). Output power is interrupted. To recover from a low battery voltage shutdown: 1. Turn off your equipment and recharge your battery. The alarm will turn off when battery voltage reaches 11.6 volts. 2. When the Low Battery light turns off (12.6 volts) and the Inverter ON light illuminates, you can restart your equipment. Restarting or Operating Multiple Pieces of Equipment The TS400 can handle several pieces of equipment simultaneously as long as they do not draw more than 400 watts in total. To restart or operate several pieces of equipment: Turn each device on separately after the TS400 has started. This action ensures that the TS400 does not have to deliver the starting current for all the loads at once and will help to prevent an overload shutdown

52 Operation Monitoring the Operating Status Table 3-2 The operating status of the TS400 is indicated by three lights on the front panel and an audible alarm. See Table 3-2. For an illustration of the indicator lights on the front panel, see Front Panel of the TS400 on page 3 2. If none of the front panel lights are on, see Troubleshooting Reference on page 4 2. Status of Indicator Lights and Alarm /LJKW &RORU 6WDWXV $FWLRQ Inverter ON Green When the TS400 is on, the Inverter ON light illuminates. Low Battery & Inverter ON (with audible alarm) Low Battery (with audible alarm) Yellow & Green Yellow When the Low Battery and Inverter ON lights illuminate, your battery level is low. (The battery voltage has dropped below 10.7 volts DC.) When only the Low Battery light illuminates, your battery level is critically low. (The battery voltage has dropped below 10.3 volts DC.) Fault Red The Fault light illuminates whenever there is a battery overvoltage fault condition (exceeds 15.3 volts), output overload fault condition or over-temperature fault condition. You can run your equipment using energy from the battery. You can run your equipment but your battery level is low. Charge your battery. You cannot run equipment. Charge your battery. You cannot run equipment as the AC output is disabled. Clear the fault condition. Reset the TS400 by turning the On/Standby switch to Standby ( ) and then to On ( )

frame bracket Ford & Dodge

frame bracket Ford & Dodge , Rev 3 02/19 frame bracket 8552005 Ford & Dodge ITEM PART # QTY DESCRIPTION 1 00083 8 NUT,.50NC HEX 2 00084 8 WASHER,.50 LOCK 3 14189-76 2 FRAME BRACKET 4 14194-76 1 411AL FRAME BRACKET PASSENGER SIDE

Læs mere

Lithium-Ion Jump-Starters / Jumper Cables

Lithium-Ion Jump-Starters / Jumper Cables AUTOMOTIVE Lithium-Ion Jump-Starters / Jumper Cables Lithium-Ion Jump-Starter 1300: Part No. DRLJS130 1300 4 6 8 cylinder (6 liter gas 3 liter diesel) SafeJump technology prevents sparking and protects

Læs mere

INSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960!

INSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960! Materials supplied: 1. (10) Zip Ties 2. (4) Hose Clamps 3. (2) Brake Duct Hose 4. (2) Brake Shields 5. (2) Front Brake Ducts ( Stock Fascia Only ) 6. (2) Washers 1 OD ( Stock Fascia Only ) 7. (8) Shims

Læs mere

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL! DANSK INSTALLATIONSVEJLEDNING VLMT500 Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse. Kontroller at

Læs mere

UNISONIC TECHNOLOGIES CO.,

UNISONIC TECHNOLOGIES CO., UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output

Læs mere

Sikkerhedsvejledning

Sikkerhedsvejledning 11-01-2018 2 Sikkerhedsvejledning VIGTIGT! Venligst læs disse instruktioner inden sengen samles og tages i brug Tjek at alle dele og komponenter er til stede som angivet i vejledningen Fjern alle beslagsdele

Læs mere

Assembly Instructions. ROLZ-2 Portable AV/Conference Center

Assembly Instructions. ROLZ-2 Portable AV/Conference Center 1 Assembly Instructions ROLZ-2 Portable AV/Conference Center Rolz-2 Portable AV/Conference Center Part Drawing Description Qty Part Drawing Description Qty Hardware List A 1 ½ Flat Head Screw 2 EA P-1

Læs mere

MS-H280-Pro Magnetic Stirrer

MS-H280-Pro Magnetic Stirrer MS-H280-Pro Magnetic Stirrer www..com Copyright: No part of this manual may be reproduced or transmitted without prior written permission of. VERSION201407 CONTENTS Chapter 1: Working Principle... 3 1

Læs mere

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove Manual Transmission Remove and Install (,0 DOHC 8V Engine) (6 4 0) Workshop Equipment Transmission jack Materials Brake fluid (Super Dot 4) ESD-M6C57-A Remove. Standard preparatory measures: Make a note

Læs mere

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1 Project Step 7 Behavioral modeling of a dual ported register set. Copyright 2006 - Joanne DeGroat, ECE, OSU 1 The register set Register set specifications 16 dual ported registers each with 16- bit words

Læs mere

DET KONGELIGE BIBLIOTEK NATIONALBIBLIOTEK OG KØBENHAVNS UNIVERSITETS- BIBLIOTEK. Index

DET KONGELIGE BIBLIOTEK NATIONALBIBLIOTEK OG KØBENHAVNS UNIVERSITETS- BIBLIOTEK. Index DET KONGELIGE Index Download driver... 2 Find the Windows 7 version.... 2 Download the Windows Vista driver.... 4 Extract driver... 5 Windows Vista installation of a printer.... 7 Side 1 af 12 DET KONGELIGE

Læs mere

WIO200A INSTALLATIONS MANUAL Rev Dato:

WIO200A INSTALLATIONS MANUAL Rev Dato: WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of

Læs mere

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Constant Terminal Voltage. Industry Workshop 1 st November 2013 Constant Terminal Voltage Industry Workshop 1 st November 2013 Covering; Reactive Power & Voltage Requirements for Synchronous Generators and how the requirements are delivered Other countries - A different

Læs mere

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator Opera Ins Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator I.Precautions 1. Keep the product away from children to avoid children playing it as a toy and resultinginpersonalinjury.

Læs mere

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

Portal Registration. Check Junk Mail for activation  . 1 Click the hyperlink to take you back to the portal to confirm your registration Portal Registration Step 1 Provide the necessary information to create your user. Note: First Name, Last Name and Email have to match exactly to your profile in the Membership system. Step 2 Click on the

Læs mere

PMDK PC-Side Basic Function Reference (Version 1.0)

PMDK PC-Side Basic Function Reference (Version 1.0) PMDK PC-Side Basic Function Reference (Version 1.0) http://www.icpdas.com PMDK PC-Side Basic Function Reference V 1.0 1 Warranty All products manufactured by ICPDAS Inc. are warranted against defective

Læs mere

DANSK INSTALLATIONSVEJLEDNING VLMW2355A ADVARSEL! VESA Standarder: 100x100, 200x100, 200x200, Op til 35 kg. 300x300, 400x200 og 400x400

DANSK INSTALLATIONSVEJLEDNING VLMW2355A ADVARSEL! VESA Standarder: 100x100, 200x100, 200x200, Op til 35 kg. 300x300, 400x200 og 400x400 DANSK INSTALLATIONSEJLEDNING LMW2355A ESA Standarder: ægt: 100x100, 200x100, 200x200, Op til 35 kg. 300x300, 400x200 og 400x400 Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på

Læs mere

Brugsanvisning. Installation Manual

Brugsanvisning. Installation Manual Manual size: 148 x 210 mm 175g copper paper(铜版纸印刷) UNIVERSAL BIL TAGBAGAGEBÆRER Brugsanvisning UNIVERSAL CAR ROOF RACK Installation Manual Model no. 10889 Tak fordi du valgte dette produkt, som vi håber

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK). DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

DANSK. INSTALLATIONSVEJLEDNING DS Pro Lærred med motor ADVARSEL!

DANSK. INSTALLATIONSVEJLEDNING DS Pro Lærred med motor ADVARSEL! DANSK INSTALLATIONSVEJLEDNING DS Pro Lærred med motor Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse.

Læs mere

RPW This app is optimized for: For a full list of compatible phones please visit radiation. result.

RPW This app is optimized for: For a full list of compatible phones please visit   radiation. result. TM TM RPW-1000 Laser Distance Measurer This app is optimized for: For a full list of compatible phones please visit www.ryobitools.eu/phoneworks IMPORTANT SAFETY S READ AND UNDERSTAND ALL INSTRUCTIONS.

Læs mere

Recall information fra C. Reinhardt

Recall information fra C. Reinhardt Ballerup, den 19. januar 2016 Recall information fra C. Reinhardt Kære alle Vi har modtaget en recall fra Suzuki Global. I dette brev kan du læse de vigtigste punkter vedrørende problemerne og hvordan

Læs mere

Slot diffusers. Slot diffusers LD-17, LD-18

Slot diffusers. Slot diffusers LD-17, LD-18 LD-17, LD-18 Application LD-17 and LD-18 are designed for supply of cold or warm air in rooms with a height between. m and 4 m. They allow easy setting of air deflectors for different modes of operation

Læs mere

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Dansk standard Tillæg DS/IEC 60335-1/A1:2013 + Corr 1:2014 1. udgave 2014-05-08 Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Household and similar electrical appliances

Læs mere

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 DK: Davo-Meg 1002: 87 98 301 819 Davo-Meg 1002B: 87 98 301 822 EAN: Davo-Meg 1002: 5703534100059 Davo-Meg 1002B: 5703534100202 Indhold

Læs mere

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc.

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc. LINK-56K Emulator for Motorola s DSPs A Product of Domain Technologies, Inc. LINK-56K User s Guide, Version1.05 September, 2003 DSPs supported by this product: Motorola DSP56001 Motorola DSP56002 and derivatives

Læs mere

User Manual for LTC IGNOU

User Manual for LTC IGNOU User Manual for LTC IGNOU 1 LTC (Leave Travel Concession) Navigation: Portal Launch HCM Application Self Service LTC Self Service 1. LTC Advance/Intimation Navigation: Launch HCM Application Self Service

Læs mere

Plug Connectors for Food & Beverage

Plug Connectors for Food & Beverage Plug Connectors for Food & Beverage Made with stainless steel Food grade quality High protection degree MeeTS DEMANDING HYGIENIC STANDARDS The food and beverage industry needs an extremely clean environment

Læs mere

ELECTRONIC CONTROL BOX 20-0344

ELECTRONIC CONTROL BOX 20-0344 ELECTRONIC CONTROL BOX 20-0344 Specifications Rated voltage: Rated power: Rated current: Pump load: Blower (aux) load: Light load: Heater load: 400V, 50 Hz 11000 W 3 x 16 A Max. 3 x 3000 W Total sum of

Læs mere

QUICK START Updated:

QUICK START Updated: QUICK START Updated: 24.08.2018 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get started

Læs mere

Black Jack --- Review. Spring 2012

Black Jack --- Review. Spring 2012 Black Jack --- Review Spring 2012 Simulation Simulation can solve real-world problems by modeling realworld processes to provide otherwise unobtainable information. Computer simulation is used to predict

Læs mere

Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov.

Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov. På dansk/in Danish: Aarhus d. 10. januar 2013/ the 10 th of January 2013 Kære alle Chefer i MUS-regi! Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov. Og

Læs mere

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package High Speed LDO Regulators, High PSRR, Low noise, Series General Description The series are highly accurate, low noise, CMOS LDO Voltage Regulators. Offering low output noise, high ripple rejection ratio,

Læs mere

DANSK / ENGLISH DS PRO PROJEKTORBESLAG 180 CM MANUAL DS PRO PROJECTOR BRACKET 180 CM OWNERS MANUAL

DANSK / ENGLISH DS PRO PROJEKTORBESLAG 180 CM MANUAL DS PRO PROJECTOR BRACKET 180 CM OWNERS MANUAL DANSK / ENGLISH DANSK SIDE 1 DS Pro PRO projektorbeslag PROJEKTORBESLAG 180 cm 180 CM Tillykke med dit nye DS Pro projektorbeslag 180 cm. For at opnå det bedste resultat bedes du læse denne manual og udelukkende

Læs mere

R9H R9H R9H R9H R9H R9H R9H13303

R9H R9H R9H R9H R9H R9H R9H13303 Resi9 en da R9H84 - R9H84 - R9H84 - R9H844 - R9H0 - R9H0 - R9H0 IP0 NVE5695 http://tv.schneider-electric.com This service guide must be kept for future use. PLEASE NOTE bbthis equipment should be installed,

Læs mere

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS). Bilag 8. TDC technical requirements for approval of splitters and inline s intended for shared access (ADSL or VDSL over POTS). Dette bilag udgør bilag 8 til det mellem parterne tiltrådte Produkttillæg

Læs mere

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen

Læs mere

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med

Læs mere

TDC 4 Indoor voltage transformers

TDC 4 Indoor voltage transformers Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,

Læs mere

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss Brugervejledning (side 2-6) Userguide (page 7-11) Bedienungsanleitung 1 - Hvordan forbinder du din E-PAD hængelås med din

Læs mere

DANSK INSTALLATIONSVEJLEDNING VLMC101-H ADVARSEL!

DANSK INSTALLATIONSVEJLEDNING VLMC101-H ADVARSEL! DANSK INSTALLATIONSVEJLEDNING VLMC101-H Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse. Kontroller

Læs mere

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation PEMS RDE Workshop AVL M.O.V.E Integrative Mobile Vehicle Evaluation NEW - M.O.V.E Mobile Testing Platform Key Requirements for Measuring Systems Robustness Shock / vibrations Change of environment Compact

Læs mere

STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX. STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Hardware Description LIG1014A LIG1080A TABLE

Læs mere

Hi-Res Audio/DNC Headset MDR-NC750

Hi-Res Audio/DNC Headset MDR-NC750 Brugervejledning Hi-Res Audio/DNC Headset MDR-NC750 Indholdsfortegnelse Introduktion... 3 Introduktion...3 Oversigt... 3 De grundlæggende funktioner... 4 Sådan bærer du headsettet... 4 Tilslutning af dit

Læs mere

Clear aim to ensure safety of all people involved in optical links project Scope

Clear aim to ensure safety of all people involved in optical links project Scope Laser Safety Outline Clear aim to ensure safety of all people involved in optical links project Scope Hazard classification of CMS Tracker readout link system Requirements Note: Safety requirements here

Læs mere

Basic statistics for experimental medical researchers

Basic statistics for experimental medical researchers Basic statistics for experimental medical researchers Sample size calculations September 15th 2016 Christian Pipper Department of public health (IFSV) Faculty of Health and Medicinal Science (SUND) E-mail:

Læs mere

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting LED Drivers CV EASYLINE CV 48 V EasyLine 48 V C-L 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V C-L VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT POWER

Læs mere

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals Solenoid valves Control valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)1-73-0 Fax: +49(0)1-73-281 e-mail: info@akmueller.de Internet: www.akmueller.de

Læs mere

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color

Læs mere

100% Den nye generation af varmelampe VEDLIGEHOLDELSES FRI MONTERINGS VEJLEDNING

100% Den nye generation af varmelampe VEDLIGEHOLDELSES FRI MONTERINGS VEJLEDNING BESKRIVELSE The new generation af of varmelampe heating lamps Den nye generation Den nye generation af varmelampe 100% VEDLIGEHOLDELSES FRI Volt 220 240 Forbrug 100W eller 150W Tilslutning Vælg det stik/tilslutning

Læs mere

PARALLELIZATION OF ATTILA SIMULATOR WITH OPENMP MIGUEL ÁNGEL MARTÍNEZ DEL AMOR MINIPROJECT OF TDT24 NTNU

PARALLELIZATION OF ATTILA SIMULATOR WITH OPENMP MIGUEL ÁNGEL MARTÍNEZ DEL AMOR MINIPROJECT OF TDT24 NTNU PARALLELIZATION OF ATTILA SIMULATOR WITH OPENMP MIGUEL ÁNGEL MARTÍNEZ DEL AMOR MINIPROJECT OF TDT24 NTNU OUTLINE INEFFICIENCY OF ATTILA WAYS TO PARALLELIZE LOW COMPATIBILITY IN THE COMPILATION A SOLUTION

Læs mere

frame bracket Dodge Ram x2 & 4x4 (Includes Mega Cab) (6-1/2 & 8 Boxes)

frame bracket Dodge Ram x2 & 4x4 (Includes Mega Cab) (6-1/2 & 8 Boxes) , Rev 4 03/19 frame bracket 8551006 Dodge Ram 3500 4x2 & 4x4 (Includes Mega Cab) (6-1/2 & 8 Boxes) ITEM PART # QTY DESCRIPTION 1 00248 4 WASHER,.625 SPRING LOCK 2 00291 4 NUT,.625NC HEX 3 00477 4 WASHER,.625

Læs mere

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax TM4 Central Station User Manual / brugervejledning K2070-EU STT Condigi A/S Niels Bohrs Vej 42, Stilling 8660 Skanderborg Denmark Tel. +45 87 93 50 00 Fax. +45 87 93 50 10 info@sttcondigi.com www.sttcondigi.com

Læs mere

SmartDock for Xperia ion Brugervejledning

SmartDock for Xperia ion Brugervejledning SmartDock for Xperia ion Brugervejledning Indholdsfortegnelse Indledning...3 Oversigt over SmartDock...3 Opladning med SmartDock...3 Kom godt i gang...5 LiveWare -administration...5 Opgradering af LiveWare

Læs mere

QUICK START Updated: 18. Febr. 2014

QUICK START Updated: 18. Febr. 2014 QUICK START Updated: 18. Febr. 2014 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get

Læs mere

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA TekVor 1300C 1. Before You Begin This guide provides basic guidelines to assist you in quickly getting started. Installation of the transmitter in an explosive environment must be in accordance with the

Læs mere

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support: Industrial flexible rubber cable range with an insulation and sheath in elastomers. Cables for heavy duty uses, Oil resistant and Flame retardancy according to IEC/EN 60332-1-2 standard. BESKRIVELSE Application

Læs mere

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307346 EN Motion detector LUXA 103-100 U WH 1030040 LUXA 103-100 UA WH 1030045 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing

Læs mere

Instructions for use www.nilfisk-advance.com 1 2 3 PRECAUTIONARY MEASURES If the opening that sucks in the air, thesuction pipe orthe telescopic wand on pipe are blocked, you should switch off the vacuum

Læs mere

Brugervejledning. MHL to HDMI Adapter IM750

Brugervejledning. MHL to HDMI Adapter IM750 Brugervejledning MHL to HDMI Adapter IM750 Indholdsfortegnelse Indledning...3 Oversigt over MHL to HDMI Adapter...3 Kom godt i gang...4 Smart Connect...4 Opgradering af Smart Connect...4 Brug af MHL to

Læs mere

Brugervejledning. Xperia P TV Dock DK21

Brugervejledning. Xperia P TV Dock DK21 Brugervejledning Xperia P TV Dock DK21 Indholdsfortegnelse Indledning...3 Bagside oversigt over TV Dock...3 Kom godt i gang...4 Håndtering af LiveWare...4 Opgradering af Håndtering af LiveWare...4 Brug

Læs mere

United Nations Secretariat Procurement Division

United Nations Secretariat Procurement Division United Nations Secretariat Procurement Division Vendor Registration Overview Higher Standards, Better Solutions The United Nations Global Marketplace (UNGM) Why Register? On-line registration Free of charge

Læs mere

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B. Mandara 1,884 sq. ft. Tradition Series Exterior Design A Exterior Design B Exterior Design C Exterior Design D 623.935.6700 robson.com Tradition OPTIONS Series Exterior Design A w/opt. Golf Cart Garage

Læs mere

Xperia TX TV Dock DK22 Xperia T TV Dock DK23

Xperia TX TV Dock DK22 Xperia T TV Dock DK23 Brugervejledning Xperia TX TV Dock DK22 Xperia T TV Dock DK23 Indholdsfortegnelse Indledning...3 Oversigt over TV Dock...3 Kom godt i gang...4 Smart Connect...4 Opgradering af Smart Connect...4 Brug af

Læs mere

Læs vejledningen godt igennem, før du begynder at samle vuggen. Please read the instruction carefully before you start.

Læs vejledningen godt igennem, før du begynder at samle vuggen. Please read the instruction carefully before you start. 00 Samlevejledning på Vugge ssembly instruction for the cradle Læs vejledningen godt igennem, før du begynder at samle vuggen. Please read the instruction carefully before you start. www.oliverfurniture.dk

Læs mere

Engelsk. Niveau D. De Merkantile Erhvervsuddannelser September Casebaseret eksamen. og

Engelsk. Niveau D. De Merkantile Erhvervsuddannelser September Casebaseret eksamen.  og 052431_EngelskD 08/09/05 13:29 Side 1 De Merkantile Erhvervsuddannelser September 2005 Side 1 af 4 sider Casebaseret eksamen Engelsk Niveau D www.jysk.dk og www.jysk.com Indhold: Opgave 1 Presentation

Læs mere

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Unitel EDI MT940 June 2010 Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Contents 1. Introduction...3 2. General...3 3. Description of the MT940 message...3 3.1.

Læs mere

Sikkerhed & Revision 2013

Sikkerhed & Revision 2013 Sikkerhed & Revision 2013 Samarbejde mellem intern revisor og ekstern revisor - og ISA 610 v/ Dorthe Tolborg Regional Chief Auditor, Codan Group og formand for IIA DK RSA REPRESENTATION WORLD WIDE 300

Læs mere

BACKGUARD FOR PROFESSIONAL RANGES

BACKGUARD FOR PROFESSIONAL RANGES FOR PROFESSIONAL RANGES BGRV2 models INSTALLATION GUIDE US CA 591091C 01.18 1 SAFETY AND WARNINGS WARNING! Cut Hazard Take care some edges are sharp. Failure to use caution could result in injury or cuts.

Læs mere

HR7775, HR7774. 4203.000.5832.4.indd 1 15-09-09 15:28

HR7775, HR7774. 4203.000.5832.4.indd 1 15-09-09 15:28 HR7775, HR7774 4203.000.5832.4.indd 1 15-09-09 15:28 EN DA DE EL ES FI FR IT NL NO PT SV TR English Dansk Deutsch Ελληνικα Español Suomi Français Italiano Nederlands Norsk Português Svenska Türkçe AR FA

Læs mere

TGP 15 H. Betjeningsvejledning. Texas Power Line Pumper 2003 / 2

TGP 15 H. Betjeningsvejledning. Texas Power Line Pumper 2003 / 2 2003 / 2 Betjeningsvejledning Texas Power Line Pumper TGP 15 H Texas Andreas Petersen A/S Knullen 2 DK-5260 Odense S Tlf. 6395 5555 Fax 6395 5558 post@texas.dk - www.texas.dk ADVARSEL - Læs altid betjeningsvejledningen

Læs mere

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400 BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400 BETJENINGSVEJLEDNING 1. Vigtigt: Før du tilslutter spændingstransformerne til stikkontakten i dit hjem, skal du sørge

Læs mere

SAF Brake Cylinders for disc brakes. Installation and Service Guide

SAF Brake Cylinders for disc brakes. Installation and Service Guide SAF Brake Cylinders for disc brakes Contents Contents... 1 Safety Information... 2 Installation of the SAF Brake Cylinders... 3 Installation of the Single Diaphragm Cylinder... 3 Installation of the Double

Læs mere

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1 IBM Network Station Manager esuite 1.5 / NSM Integration IBM Network Computer Division tdc - 02/08/99 lotusnsm.prz Page 1 New esuite Settings in NSM The Lotus esuite Workplace administration option is

Læs mere

Vina Nguyen HSSP July 13, 2008

Vina Nguyen HSSP July 13, 2008 Vina Nguyen HSSP July 13, 2008 1 What does it mean if sets A, B, C are a partition of set D? 2 How do you calculate P(A B) using the formula for conditional probability? 3 What is the difference between

Læs mere

- The knowledge to make a difference

- The knowledge to make a difference - The knowledge to make a difference TILLYKKE MED DIT NYE AKVARIUM Denne vejledning vil hjælpe dig let gennem opstilling og samling af dit nye MOVE akvarium. Vi anbefaler du læser vejledningen grundigt

Læs mere

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B. Mandara 1,884 sq. ft. Tradition Series Exterior Design A Exterior Design B Exterior Design C Exterior Design D 623.935.6700 robson.com Tradition Series Exterior Design A w/opt. Golf Cart Garage Exterior

Læs mere

WIO200A Water in oil sensor

WIO200A Water in oil sensor WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic

Læs mere

TELT. Oversigt over dele. Følg opstillingsanvisningerne for at opnå det bedste resultat.

TELT. Oversigt over dele. Følg opstillingsanvisningerne for at opnå det bedste resultat. TELT Følg opstillingsanvisningerne for at opnå det bedste resultat. Opstillingstid: ca. 25 min. Krævet antal personer til opstilling: 2 Oversigt over dele Kabine Pløkker (18 stk.) Yderdug Bæretaske Ekstra

Læs mere

DK - Quick Text Translation. HEYYER Net Promoter System Magento extension

DK - Quick Text Translation. HEYYER Net Promoter System Magento extension DK - Quick Text Translation HEYYER Net Promoter System Magento extension Version 1.0 15-11-2013 HEYYER / Email Templates Invitation Email Template Invitation Email English Dansk Title Invitation Email

Læs mere

Shooting tethered med Canon EOS-D i Capture One Pro. Shooting tethered i Capture One Pro 6.4 & 7.0 på MAC OS-X 10.7.5 & 10.8

Shooting tethered med Canon EOS-D i Capture One Pro. Shooting tethered i Capture One Pro 6.4 & 7.0 på MAC OS-X 10.7.5 & 10.8 Shooting tethered med Canon EOS-D i Capture One Pro Shooting tethered i Capture One Pro 6.4 & 7.0 på MAC OS-X 10.7.5 & 10.8 For Canon EOS-D ejere der fotograferer Shooting tethered med EOS-Utility eller

Læs mere

DAY HUNTER KIT ASSEMBLY INSTRUCTIONS

DAY HUNTER KIT ASSEMBLY INSTRUCTIONS DAY HUNTER KIT ASSEMBLY INSTRUCTIONS Attach the Shoulder Harness to the Frame 1. Pass the Upper Harness Attachment Straps (Diagram 1.) through the attachment points located inboard on the upper portion

Læs mere

South Baileygate Retail Park Pontefract

South Baileygate Retail Park Pontefract Key Details : available June 2016 has a primary shopping catchment of 77,000 (source: PMA), extending to 186,000 within 10km (source: FOCUS) 86,000 sq ft of retail including Aldi, B&M, Poundstretcher,

Læs mere

ELECTRONIC CONTROL BOX 20-0313

ELECTRONIC CONTROL BOX 20-0313 ELECTRONIC CONTROL BOX 20-0313 Specifications Rated voltage: Rated power: Rated current: Output A: Output B: Output C: 230VAC, 50Hz, single phase 2300W 10 A Max. 900W The total sum of the loads must not

Læs mere

Den nye Eurocode EC Geotenikerdagen Morten S. Rasmussen

Den nye Eurocode EC Geotenikerdagen Morten S. Rasmussen Den nye Eurocode EC1997-1 Geotenikerdagen Morten S. Rasmussen UDFORDRINGER VED EC 1997-1 HVAD SKAL VI RUNDE - OPBYGNINGEN AF DE NYE EUROCODES - DE STØRSTE UDFORDRINGER - ER DER NOGET POSITIVT? 2 OPBYGNING

Læs mere

Beovox 5000 versions. Classic Audio Technical Information

Beovox 5000 versions. Classic Audio Technical Information Beovox 5000 versions Bang & Olufsen designed the Beovox 5000 for the Beolab 5000. During the period the Beolab 5000 was available (1967 1972) 3 different versions of the Beovox 5000 were released. In this

Læs mere

High Voltage AC & DC Film Capacitors

High Voltage AC & DC Film Capacitors RoHS COMPLIANT High Voltage AC & DC Film Capacitors Aerovox high voltage capacitors are constructed with metallized polypropylene film and are available in round or oval aluminum cases with four-blade

Læs mere

IPTV Box (MAG250/254) Bruger Manual

IPTV Box (MAG250/254) Bruger Manual IPTV Box (MAG250/254) Bruger Manual Når din STB (Set top Box) starter op, bliver der vist en pop up boks på skærmen, hvor du kan åbne EPG ved at trykke på F2 (Nogle bokse kan fortælle at den har brug for

Læs mere

Metal Oxide Varistor:TVM-B Series

Metal Oxide Varistor:TVM-B Series Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction

Læs mere

Assembly Guide Monteringsvejledning. 60/30 - wood end panels

Assembly Guide Monteringsvejledning. 60/30 - wood end panels Assembly Guide Monteringsvejledning 60/30 - wood end panels Wood end panels 1. When installing wood end panels, insert the top fittings into the upper crossbar slots and place the Z brackets over the foot

Læs mere

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17 SkyVision Comfort Installation manual 5.6.02_0517, Comfort, Item no. 2022 Version 05/17 Installation Manual VITRAL SkyVision Comfort Trækarme skal altid opbevares tørt/ Wooden upstands must always be kept

Læs mere

ROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning. ROTATING SHOWER STOOL WITH TRAY Installation Manual. Size: 148 x 210 mm 105g copper paper

ROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning. ROTATING SHOWER STOOL WITH TRAY Installation Manual. Size: 148 x 210 mm 105g copper paper Size: 148 x 210 mm 105g copper paper ROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning ROTATING SHOWER STOOL WITH TRAY Installation Manual Model. 10853 1. Fjern emballagen. 2. Taburettens ben samles

Læs mere

Advarsel: Læs alle instrukser og færdiggør samlingen før brug. Det kan være en fordel at være to til at samle trampolinen.

Advarsel: Læs alle instrukser og færdiggør samlingen før brug. Det kan være en fordel at være to til at samle trampolinen. InGround trampolin Advarsel: - Indeholder små dele som kan forårsage kvælning. - Trampolinen må ikke bruges af børn under 3 år. - For at undgå at glide, bør trampolinen ikke bruges når den er våd. - Kun

Læs mere

SkyVision Linear Installation manual, comfort _0216, Comfort, Item no Version 02/16

SkyVision Linear Installation manual, comfort _0216, Comfort, Item no Version 02/16 SkyVision Linear Installation manual, comfort 5.6.07_06, Comfort, Item no. 0606 Version 0/6 Installation Manual VITRAL SkyVision Linear Comfort Trækarme skal altid opbevares tørt/ Wooden upstands must

Læs mere

Resource types R 1 1, R 2 2,..., R m CPU cycles, memory space, files, I/O devices Each resource type R i has W i instances.

Resource types R 1 1, R 2 2,..., R m CPU cycles, memory space, files, I/O devices Each resource type R i has W i instances. System Model Resource types R 1 1, R 2 2,..., R m CPU cycles, memory space, files, I/O devices Each resource type R i has W i instances. Each process utilizes a resource as follows: request use e.g., request

Læs mere

CART MULTITEK CART MULTITEK CART. The MultiTek Cart

CART MULTITEK CART MULTITEK CART. The MultiTek Cart CART INDEX PAGE(S) The MultiTek Cart 180-181 180 ROUSSEAUMETAL.COM INFO@ROUSSEAUMETAL.COM CART THE ROUSSEAU DIFFERENCE LOCKABLE COVER Opens 90 for unrestricted access to the shelf COMFORTABLE AND ERGONOMIC

Læs mere

Maneurop reciprocating compressors

Maneurop reciprocating compressors MAKING MODERN LIVING POSSIBLE Maneurop reciprocating compressors MT - MTZ - LTZ - NTZ - 60 z R404A - R507A - R407C - R134a - R22 QUICK REFERENCE PRODUCT RANGE Nominal voltage M-BP Applications LBP Applications

Læs mere

Lovkrav vs. udvikling af sundhedsapps

Lovkrav vs. udvikling af sundhedsapps Lovkrav vs. udvikling af sundhedsapps Health apps give patients better control User Data Social media Pharma Products User behaviour Relatives www Self monitoring (app) data extract Healthcare specialists

Læs mere

Special VFR. - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone

Special VFR. - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone Special VFR - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone SERA.5005 Visual flight rules (a) Except when operating as a special VFR flight, VFR flights shall be

Læs mere

Brugervejledning. Trådløst display fra Miracast IM10

Brugervejledning. Trådløst display fra Miracast IM10 Brugervejledning Trådløst display fra Miracast IM10 Indholdsfortegnelse Brugervejledning til trådløst display fra Miracast...3 Konfiguration af trådløst display fra Miracast...4 Oversigt over hardware...4

Læs mere