1
2 Indhold Bilag 1 - Projektskabelon... 3 Bilag 2 - Pareto analyse / / / Bilag 3 Gennemsnits brændstofforbrug Bilag 4 - Dataindsamling september september september september oktober Bilag 5 - Diesel fact Bilag 6 - Main Central Colling FW system Bilag 7 - Pumpe data Bilag 8 - Mail korrespondance med Ole Flyvholm Bilag 9 - Central Cooling Seawater system Bilag 10 - AUX Central Cooling FW system Bilag 11 - Motor data Bilag 12 - Mail korrespondance med Casper Bilag 13 - Pump test records LT pumper Bilag 14 - Pump test records SW pumper AUX SW Pump Main SW pumps Bilag 15 - Effekter afsat i varmeveksleren Bilag 16 - Infrarødt termometer Bilag 17 Heat Balance Sheet Normal sea going with tank cleaning or heating Normal sea going Cargo unloading Port condition Bilag 18 - Brændstof rapport Bunkring Side 1 af 96
3 Bilag 19 - Torm Estrid Bunkring Bilag 20 Brændstofforbrug Bilag 21 - Dagspris MGO og HFO Bilag 22 - Valutakurs USD -> DKK Bilag 23 - Plate Cooler No No Bilag 24 - Pressostat Bilag 25 - Mail korrespondance med Gert Andersen Bilag 26 - Beregning af drift punkt for LT pumpe Bilag 27 Beregning af minimums flow Bilag 28 - Tilbud 1 fra CS Electric Bilag 29 - Bypass ventil Bilag 30 Datablad ny pumpe Bilag 31 Beregning af flow ved parallelkoblede LT pumper Bilag 32 - Lastekonditoner Bilag 33 - Tilbud løsningsforslag Bilag 34 - Drøvle forsøg Bilag 35 - Udklip af voyage plan Bilag 36 - Beregning af driftspunkt for SW pumper Bilag 37 - Beregning af flow Bilag 38 - Tilbud SW løsningsforslag Side 2 af 96
4 Bilag 1 - Projektskabelon Emne Energioptimering af kølevandssystem Skribenter G @edu.fms.dk Morten Rauhe E @edu.fms.dk Vejledere Jan Sturm Almind - FMS [email protected] Ole Flyvholm - Torm Estrid [email protected] Problemstilling Pga. større og større konkurrence i søfarten, ser Torm sig nødsaget til at energioptimere deres flåde. Derfor ønsker de at vi undersøger om det er muligt at lave nogle energibesparelser på et af tre søskende skibe, Torm Estrid, Torm Emilie, Torm Ismini, som stadig fungere på samme måde som da skibene var nye. Torm er underlagt retningslinjer bestemt af IMO. Disse retningslinjer siger at Torm og alle andre rederier skal have fokus på energioptimering for at nedbringe emissioner i henhold til MARPOL Annex VI. Problemformulering Hvordan finder vi de største energiforbruger ombord på Torm Estrid? Hvordan er det muligt at energioptimere kølevandssystemet ombord på de tre søskende skibe Torm Estrid, Torm Emilie, Torm Ismini? Hvor stor en økonomisk besparelse kan der opnås ved energioptimering af kølevandssystemet? Side 3 af 96
5 Hypotese Ved at energioptimere kølevandssystemet er det muligt at lave en økonomisk besparelse på kr. om året. Ved at installere frekvensomformere på pumperne i kølevandssystemet, vil denne løsning have den hurtigste tilbagebetalingstid. De pumper som driver kølevandssystemet er mellem de 10 største forbrugere ombord. Metode For at anskueliggøre hvor i kølevandsystemet, det er muligt at lave en energioptimering, vil tegninger på kølevandssystemet blive analyseret grundigt før dataindsamling. Ud fra disse tegninger vil vi opbygge en matrix, hvor det er muligt at notere de forskellige værdier foretaget i dataindsamlingen ombord. Matrixen skal gøre det muligt for os, at tjekke kølebehovet, samt sammenligne de forskellige værdier i forskellige konditioner og ved forskellige hav temperaturer. Dataindsamling til vores analyse, samt observationerne ombord på Torm Estrid er baseret på vores 10 ugers praktikophold. Ud fra tegninger og runderinger i maskinrummet, vil vi beskrive kølevandssystemet med egne ord. På baggrund af matrixen, analysen og observationer ombord på Torm Estrid vil vi komme med forskellige løsninger, hvorpå en energioptimering af kølevandssystemerne ombord på de 3 søskende skibe kan opnås. Løsningerne vil udelukkende være basseret på de dataindsamlinger vi har taget ombord på Torm Estrid og hvilket farvand dette skib har sejlet i under dataindsamlingen. Side 4 af 96
6 Løsningerne er basseret ud fra effektformlen m*c* t, på de forskellige kølevandssystemer og ved hjælp af teknisk indsigt i hele kølevandssystemet. Vi vil ud fra de mulige løsninger beregne brændstofbesparelsen for at se hvilke af løsningerne der er mest økonomiske i drift. Ud fra denne brændstofbesparelse vil vi så udregne tilbagebetalingstiden, for hver enkel løsning. Vi vil herefter diskutere fordele og ulemper ved de forskellige løsninger og derefter vurdere hvilken løsning som egner sig bedst i henhold til driftssikkerheden af systemet, samt tilbagebetalingstiden for investeringen. Ved hjælp af den valgte løsning, vil vi komme med et forslag til implementering af energioptimering af kølevandssystemet. Projektets delopgaver Analysere kølevandsystemet ved hjælp af tegninger Beskrive hvordan kølevandsystemet virker Udarbejde en matrix til dataindsamling Foretage dataindsamling ved forskellige konditioner Analysere kølevandssystemet visuelt og finde energioptimerings tiltag Udarbejdelse af mulige løsninger til energioptimering Finde besparelsen og tilbagebetalingstiden for hver enkel løsning Diskutere fordele og ulemper ved de forskellige løsninger Anbefale en løsning Side 5 af 96
7 Bilag 2 - Pareto analyse 26/ Komponent Load (A) Forbrug (kw) forbrug (fuel/døgn) E/R Fan NO ,4 E/R Fan NO ,5 114,9 E/R Fan NO ,5 114,9 E/R Fan NO ,5 114,9 Main L.O Pump NO Main L.O Pump NO Stern tube L.O pump NO. 1 1,5 1 6,2 M/E F.O Circ. Pump NO G/E F.O Booster Pump NO. 1 2,2 1,4 8,7 I/G Deck seal S.W pump NO I/G Deck seal S.W pump NO. 2 2,6 1,6 9,9 Aux feed Pump NO. 1 6,8 4,3 26,7 M/E F.O Supply Pump NO G/E F.O Supply Pump NO G/E F.O Supply Pump NO. 2 1,5 1 6,2 M/E F.O Supply Pump NO. 2 2,5 1,6 9,9 Boiler Water circ Pump NO Boiler Water circ Pump NO.2 2,5 1,6 9,9 M/E Jacket C.F.W Pump NO M/E Jacket C.F.W Pump NO ,5 114,9 Boiler Main feed water pump NO Boiler Main feed water pump NO Main C.S.W Pump NO Main C.S.W Pump NO Aux C.S.W Pump ,4 Central C.F.W Pump NO ,6 Central C.F.W Pump NO Central C.F.W Pump NO H.P.P Room Exh. Fan ,8 Aux feed Pump NO G/E F.O Booster Pump NO M/E F.O Circ. Pump NO. 2 5,5 3,4 21,1 Stern tube L.O pump NO Purifier Room Exh. Fan 2,6 1,5 9,3 G/E L.O Purifier 14,4 8,6 53,4 Aircondition compressor No ,9 Aircondition compressor No refigiant compressor No refigiant compressor No. 2 6,9 4,7 29,2 Work air compressor 48 32,5 201,9 Side 6 af 96
8 Starting air compressor NO Starting air compressor NO Stering gear pump NO ,5 Stering gear pump NO other equipment (approxamitnly) ,3 Boiler total ,2 4560,9 Generator Engine / Komponent Load (A) Forbrug (kw) forbrug (fuel/døgn) E/R Fan NO ,4 E/R Fan NO ,5 114,9 E/R Fan NO ,5 114,9 E/R Fan NO ,5 114,9 Main L.O Pump NO Main L.O Pump NO Stern tube L.O pump NO. 1 1,5 1 6,2 M/E F.O Circ. Pump NO G/E F.O Booster Pump NO. 1 2,2 1,4 8,7 I/G Deck seal S.W pump NO I/G Deck seal S.W pump NO. 2 2,6 1,6 9,9 Aux feed Pump NO. 1 6,8 4,3 26,7 M/E F.O Supply Pump NO G/E F.O Supply Pump NO G/E F.O Supply Pump NO. 2 1,5 1 6,2 M/E F.O Supply Pump NO. 2 2,5 1,6 9,9 Boiler Water circ Pump NO Boiler Water circ Pump NO.2 2,5 1,6 9,9 M/E Jacket C.F.W Pump NO M/E Jacket C.F.W Pump NO ,5 114,9 Boiler Main feed water pump NO Boiler Main feed water pump NO Main C.S.W Pump NO Main C.S.W Pump NO Aux C.S.W Pump ,4 Central C.F.W Pump NO ,6 Central C.F.W Pump NO Central C.F.W Pump NO H.P.P Room Exh. Fan ,8 Aux feed Pump NO G/E F.O Booster Pump NO Side 7 af 96
9 M/E F.O Circ. Pump NO. 2 5,5 3,4 21,1 Stern tube L.O pump NO F.W Gen. Ejector Pump ,6 F.W Gen. Dist. Pump 2.6 1,5 9,3 Purifier Room Exh. Fan 2,6 1,5 9,3 G/E L.O Purifier 14,4 8,6 53,4 Aircondition compressor No ,9 Aircondition compressor No refigiant compressor No refigiant compressor No. 2 6,9 4,7 29,2 Work air compressor 48 32,5 201,9 Starting air compressor NO Starting air compressor NO Stering gear pump NO ,5 Stering gear pump NO other equipment (approxamitnly) ,3 Boiler total ,7 5475,8 Generator engine / Komponent Load (A) Forbrug (kw) forbrug (kg fuel/døgn) E/R Fan NO ,4 E/R Fan NO ,5 114,9 E/R Fan NO ,5 114,9 E/R Fan NO ,5 114,9 Main L.O Pump NO Main L.O Pump NO Stern tube L.O pump NO. 1 1,5 1 6,2 M/E F.O Circ. Pump NO G/E F.O Booster Pump NO. 1 2,2 1,4 8,7 I/G Deck seal S.W pump NO I/G Deck seal S.W pump NO. 2 2,6 1,6 9,9 Aux feed Pump NO ,4 26,7 M/E F.O Supply Pump NO. 1 2,5 1,6 9,9 G/E F.O Supply Pump NO G/E F.O Supply Pump NO. 2 1,5 1 6,2 M/E F.O Supply Pump NO Boiler Water circ Pump NO Boiler Water circ Pump NO M/E Jacket C.F.W Pump NO Side 8 af 96
10 M/E Jacket C.F.W Pump NO ,5 114,9 Boiler Main feed water pump NO Boiler Main feed water pump NO Main C.S.W Pump NO Main C.S.W Pump NO Aux C.S.W Pump ,4 Central C.F.W Pump NO ,6 Central C.F.W Pump NO Central C.F.W Pump NO H.P.P Room Exh. Fan Aux feed Pump NO G/E F.O Booster Pump NO M/E F.O Circ. Pump NO. 2 5,5 3,4 21,1 Stern tube L.O pump NO Aircondition compressor No ,9 Aircondition compressor No refigiant compressor No refigiant compressor No. 2 6,9 4,7 29,2 Work air compressor 48 32,5 201,9 Starting air compressor NO Starting air compressor NO Stering gear pump NO ,5 Stering gear pump NO other equipment (approxamitnly) 42,4 263,4 Boiler total 531, ,6 Generator engine 2730 Side 9 af 96
11 Bilag 3 Gennemsnits brændstofforbrug Dato SFOC ,6 g/ekwh g/ekwh ,5 g/ekwh ,8 g/ekwh ,4 g/ekwh ,8 g/ekwh ,7 g/ekwh ,88 g/ekwh ,13 g/ekwh ,9 g/ekwh ,4 g/ekwh ,9 g/ekwh ,4 g/ekwh ,74 g/ekwh ,4 g/ekwh ,4 g/ekwh ,3 g/ekwh ,45 g/ekwh g/ekwh ,2 g/ekwh gennemsnit 257,95 g/ekwh Side 10 af 96
12 Bilag 4 - Dataindsamling 9-12 september 2016 Kølevandssystem Condition Anchor Anchor Anchor Anchor Dato Beskrivelse Enhed Drawing no. Seawater temperature 26,3 26,3 26,4 26,4 C Engine room temperature C S.W. system Main C.S.W Pump 1 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Main C.S.W Pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Aux C.S.W Pump Suction pressure 0,02 0,02 0,02 0,02 MPA Delevery pressure 0,4 0,4 0,4 0,4 MPA Temp 24,1 25,5 C Load Amp Central F.W cooler 1 S.W temperature inlet C S.W temperature outlet C S.W Pressure inlet bar S.W Pressure outlet bar Central F.W cooler 2 Side 11 af 96
13 S.W temperature inlet 26,4 24,2 21,9 22,6 C S.W temperature outlet 29,4 27,4 26,1 28,6 C S.W Pressure inlet 2,5 2,5 2,5 2,5 bar S.W Pressure outlet x x x x bar Dump cond/drain cooler S.W temperature inlet ,8 31,1 C S.W temperature outlet ,7 34,3 C Bypass cooler Closed Closed Closed Closed open/close 22V L.T. system Central cool F.W pump 1 Suction pressure 0,12 0,12 0,12 0,12 MPA Delevery pressure 0,24 0,24 0,24 0,24 MPA Temp C Load Amp Central cool F.W pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central cool F.W pump 3 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central F.W cooler 1 F.W temperature inlet 0 32,1 30,8 32,1 C F.W temperature outlet 0 32,6 30,6 32,1 C F.W Pressure inlet 0 1,6 1,6 1,6 bar F.W Pressure outlet 0 1,6 1,6 1,6 bar Central F.W cooler 2 F.W temperature inlet 32,7 31,1 29,9 31,8 C F.W temperature outlet 28 25,1 22,7 24,3 C F.W Pressure inlet x 1 1 1,1 bar F.W Pressure outlet x 1,6 1,6 1,6 bar Side 12 af 96
14 Main engine air cooler inlet temperature C outlet temperature C L.T. system consumers G/E No. 1 Inlet temperature 32,4 32,3 31,7 31,5 C outlet temperature 34,4 33, ,8 C inlet pressure 1,9 1,4 1,4 1,4 bar load kw G/E No. 2 Inlet temperature 32,4 32,1 31,6 31,8 C outlet temperature 32,6 32,6 32,6 32,5 C inlet pressure bar load kw G/E No. 3 Inlet temperature 31, ,6 32,1 C outlet temperature 32,9 36,2 36,3 36,4 C inlet pressure 0,8 0,6 0,6 0,6 bar load kw Main L.O. cooler inlet temperature 27 32,2 30,2 30,6 C outlet temperature 27 32,2 30,2 30,4 C inlet pressure 0,2 0,2 0,2 0,2 MPA outlet pressure 0,14 0,14 0,14 0,14 MPA H.T. system M/E jacket cooling F.W pump 1 inlet pressure MPA outlet pressure MPA inlet temperature C outlet temperature C Load Amp M/E jacket cooling F.W pump 2 Side 13 af 96
15 inlet pressure 0,5 0,5 0,5 0,6 MPA outlet pressure 0,46 0,46 0,46 0,46 MPA inlet temperature 69 68, ,4 C outlet temperature 69 68, ,4 C Load Amp M/E jacket F.W. preheater Inlet temperature ,9 72,1 C outlet temperature 85 75,5 79,4 80,2 C Valve valve Valve Valve open/close 8V open/close 14V open/close 15V open/close 41V Main engine Inlet temperature 73,8 74,5 71,4 70,9 C outlet temperature 73,3 73,9 71,4 71 C Inlet pressure bar outlet pressure 2,5 2,5 2,5 2,5 kgf/cm² Load kw Speed knts Torque NM Consumption g/kwh Fresh water generator Inlet temperature C outlet temperature C Inlet pressure bar outlet pressure bar Energy consumption Gensets energy consumption number of gensets is running numbers consumption pr. day 3,57 2,32 2,31 2,36 tons Total electrical load pr. day kwh SFOC 267, ,5 261,8 g/ekwh L.O consumption Side 14 af 96
16 Temp in 27 31,4 29,4 28,6 C Temp out 27 31,4 29,4 28,3 C Inlet pressure 0,05 0,05 0,05 0,05 MPA outlet pressure 0,04 0,04 0,04 0,04 MPA september 2016 Kølevandssystem Condition Anchor Anchor Anchor Anchor Dato Beskrivelse Enhed Drawing no. Seawater temperature 26,2 26,1 25,9 26,3 C Engine room temperature C S.W. system Main C.S.W Pump 1 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Main C.S.W Pump 2 Suction pressure 0 0 0,08 0 MPA Delevery pressure 0 0 0,48 0 MPA Temp ,8 0 C Load Amp Aux C.S.W Pump Suction pressure 0,02 0,02 0 0,08 MPA Delevery pressure 0,039 0, ,45 MPA Temp 26,4 24, C Load Amp Central F.W cooler 1 S.W temperature inlet C S.W temperature outlet C Side 15 af 96
17 S.W Pressure inlet bar S.W Pressure outlet bar Central F.W cooler 2 S.W temperature inlet 21,3 22,1 21,6 25,9 C S.W temperature outlet 26,9 28, ,4 C S.W Pressure inlet 2,5 2,5 3,6 3,3 bar S.W Pressure outlet 0,2 0,2 0,8 0,8 bar Dump cond/drain cooler S.W temperature inlet 26,3 28,8 30,7 31,4 C S.W temperature outlet 28,6 32,2 33,9 33 C Bypass cooler Closed Closed Closed Closed open/close 22V L.T. system Central cool F.W pump 1 Suction pressure 0,12 0,12 0,12 0,12 MPA Delevery pressure 0,24 0,24 0,24 0,23 MPA Temp 31,3 34, ,5 C Load Amp Central cool F.W pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central cool F.W pump 3 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central F.W cooler 1 F.W temperature inlet C F.W temperature outlet C F.W Pressure inlet bar F.W Pressure outlet bar Central F.W cooler 2 Side 16 af 96
18 F.W temperature inlet 31 31,9 30,8 32 C F.W temperature outlet 22,9 22,7 22,4 25,1 C F.W Pressure inlet bar F.W Pressure outlet 1,6 1,6 1,6 1,6 bar Main engine air cooler inlet temperature ,5 C outlet temperature C L.T. system consumers G/E No. 1 Inlet temperature 31,7 33, ,2 C outlet temperature 33,1 34,9 34,3 32,7 C inlet pressure 1,4 1,4 1,4 1,4 bar load kw G/E No. 2 Inlet temperature 32,3 33,7 33,4 31,2 C outlet temperature 32,7 34,4 34,8 32,6 C inlet pressure bar load kw G/E No. 3 Inlet temperature 34,9 33,3 34,3 31,3 C outlet temperature 41,9 38,8 41,6 37,4 C inlet pressure 0,8 0,6 0,6 0,6 bar outlet pressure bar load kw Main L.O. cooler inlet temperature 32,3 31,6 31,5 30,2 C outlet temperature 32, ,9 30,3 C inlet pressure 0,2 0,2 0,2 0,2 MPA outlet pressure 0,14 0,14 0,14 0,14 MPA H.T. system M/E jacket cooling F.W pump 1 inlet pressure MPA outlet pressure MPA Side 17 af 96
19 inlet temperature C outlet temperature C Load Amp M/E jacket cooling F.W pump 2 inlet pressure 0,8 0,8 0,8 0,6 MPA outlet pressure 0,46 0,46 0,46 0,46 MPA inlet temperature 70,2 69,4 67,9 68,8 C outlet temperature 70,8 70,6 69,8 69,1 C Load Amp M/E jacket F.W. preheater Inlet temperature 69,4 70,4 68,7 72,1 C outlet temperature 77,4 79,4 77,3 80 C Valve valve Valve Valve open/close 8V open/close 14V open/close 15V open/close 41V Main engine Inlet temperature 73,1 71,1 70,1 70,5 C outlet temperature 72,9 70,9 70,1 70,3 C Inlet pressure bar outlet pressure 2,5 2,5 2,5 2,5 kgf/cm² Load kw Speed knts Torque NM Consumption g/kwh Fresh water generator Inlet temperature C outlet temperature C Inlet pressure bar outlet pressure bar Energy consumption Gensets energy consumption number of gensets is running numbers consumption pr. day 2,76 2,83 2,76 2,78 tons Side 18 af 96
20 Total electrical load pr. day kwh SFOC 259,4 261,8 253,7 251,88 g/ekwh L.O consumption Temp in 33,9 33,8 33,7 32,4 C Temp out 33,9 32,3 32,8 30,8 C Inlet pressure 0,06 0,046 0,046 0,046 MPA outlet pressure 0,04 0,04 0,04 0,04 MPA september 2016 Kølevandssystem Condition Anchor Anchor Anchor Anchor Dato Beskrivelse Enhed Drawing no. Seawater temperature 26,5 26,6 26,8 26,8 C Engine room temperature C S.W. system Main C.S.W Pump 1 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Main C.S.W Pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Aux C.S.W Pump Suction pressure 0,08 0,08 0,07 0,07 MPA Delevery pressure 0,46 0,45 0,4 0,41 MPA Temp 24, ,6 23,8 C Side 19 af 96
21 Load Amp Central F.W cooler 1 S.W temperature inlet ,4 25,3 C S.W temperature outlet ,9 28,9 C S.W Pressure inlet 0 0 2,8 3 bar S.W Pressure outlet 0 0 1,2 1,1 bar Central F.W cooler 2 S.W temperature inlet 24 24,6 27,2 0 C S.W temperature outlet 28,6 29,4 23,6 0 C S.W Pressure inlet 3,3 3,3 1,3 0 bar S.W Pressure outlet 0,8 0,8 1,2 0 bar Dump cond/drain cooler S.W temperature inlet 30,4 31,1 29,5 28,5 C S.W temperature outlet 33,1 32,8 31,1 28 C Bypass cooler Closed Closed Closed Closed open/close 22V L.T. system Central cool F.W pump 1 Suction pressure 0,12 0,12 0,12 0,12 MPA Delevery pressure 0,24 0,24 0,23 0,23 MPA Temp 35,3 35,9 34,7 36,9 C Load Amp Central cool F.W pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central cool F.W pump 3 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central F.W cooler 1 F.W temperature inlet ,2 34,3 C Side 20 af 96
22 F.W temperature outlet ,3 24,2 C F.W Pressure inlet 0 0 1,6 1,6 bar F.W Pressure outlet 0 0 1,6 1,6 bar Central F.W cooler 2 F.W temperature inlet 31,7 32,4 30,5 0 C F.W temperature outlet 23,9 24,7 27,8 0 C F.W Pressure inlet bar F.W Pressure outlet 1,6 1,6 1,6 0 bar Main engine air cooler inlet temperature C outlet temperature C L.T. system consumers G/E No. 1 Inlet temperature 32,6 31,9 33,3 32,6 C outlet temperature 37,2 33,4 34,8 34,6 C outlet pressure bar load kw G/E No. 2 Inlet temperature 32,6 32,1 33,6 32,8 C outlet temperature 34,8 32,7 38,1 37,1 C inlet pressure bar load kw G/E No. 3 Inlet temperature 32,4 31,8 33,1 32,1 C outlet temperature 38,1 37,4 34,4 32,9 C inlet pressure 0,6 0,6 0,6 0,6 bar load kw Main L.O. cooler inlet temperature 30,9 30,4 31,6 30,8 C outlet temperature 30,9 30,6 31,6 30,8 C inlet pressure 0,2 0,2 0,2 0,2 MPA outlet pressure 0,14 0,14 0,14 0,14 MPA H.T. system Side 21 af 96
23 M/E jacket cooling F.W pump 1 inlet pressure MPA outlet pressure MPA inlet temperature C outlet temperature C Load Amp M/E jacket cooling F.W pump 2 inlet pressure 0,6 0,6 0,6 0,6 MPA outlet pressure 0,46 0,46 0,46 0,46 MPA inlet temperature 70,6 69,8 72,2 72,4 C outlet temperature 71,9 70,9 74,3 74 C Load Amp M/E jacket F.W. preheater Inlet temperature 73, ,4 74,2 C outlet temperature 78,1 77,9 80,1 79,1 C Valve valve Valve Valve open/close 8V open/close 14V open/close 15V open/close 41V Main engine Inlet temperature 72,2 71,3 74,3 73,7 C outlet temperature 72,1 71,3 74,1 73,4 C Inlet pressure bar outlet pressure 2,5 2,5 2,5 2,5 kgf/cm² Load kw Speed knts Torque NM Consumption g/kwh Fresh water generator Inlet temperature C outlet temperature C Inlet pressure bar outlet pressure bar Energy consumption Side 22 af 96
24 Gensets energy consumption number of gensets is running numbers consumption pr. day 2,68 2,34 3,94 2,35 tons Total electrical load pr. day kwh SFOC 266,13 263,9 260,4 252,9 g/ekwh L.O consumption Temp in 30,3 31,3 30,9 28 C Temp out 30,4 31,3 30,9 29,7 C Inlet pressure 0,06 0,06 0,06 0,06 MPA outlet pressure 0,06 0,05 0,05 0,05 MPA september 2016 Kølevandssystem Condition Anchor Anchor Anchor Anchor Dato Beskrivelse Enhed Drawing no. Seawater temperature 26,9 26,6 26,8 27,2 C Engine room temperature C S.W. system Main C.S.W Pump 1 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Main C.S.W Pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Side 23 af 96
25 Aux C.S.W Pump Suction pressure 0,07 0,07 0,07 0,07 MPA Delevery pressure 0,41 0,41 0,41 0,41 MPA Temp 23,9 24,9 24,1 25,1 C Load Amp Central F.W cooler 1 S.W temperature inlet 24,1 23,6 25,8 25,6 C S.W temperature outlet 29,1 27,3 31,1 30,3 C S.W Pressure inlet bar S.W Pressure outlet bar Central F.W cooler 2 S.W temperature inlet C S.W temperature outlet C S.W Pressure inlet bar S.W Pressure outlet bar Dump cond/drain cooler S.W temperature inlet 30, ,3 C S.W temperature outlet 30,6 29,9 32,5 30,2 C Bypass cooler Closed Closed Closed Closed open/close 22V L.T. system Central cool F.W pump 1 Suction pressure 0,12 0,12 0,12 0,12 MPA Delevery pressure 0,24 0,24 0,22 0,22 MPA Temp 36,8 34,6 40,7 40,6 C Load Amp Central cool F.W pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Central cool F.W pump 3 Suction pressure MPA Delevery pressure MPA Temp C Side 24 af 96
26 Load Amp Central F.W cooler 1 F.W temperature inlet 32,8 33,5 38,4 37,9 C F.W temperature outlet 23,6 23,8 25,4 24,8 C F.W Pressure inlet 1,6 1,6 1,6 1,5 bar F.W Pressure outlet 1,6 1,6 1,6 1,5 bar Central F.W cooler 2 F.W temperature inlet C F.W temperature outlet ,7 C F.W Pressure inlet ,8 bar F.W Pressure outlet ,5 bar Main engine air cooler inlet temperature C outlet temperature C L.T. system consumers G/E No. 1 Inlet temperature 34,1 34, ,5 C outlet temperature 35,3 38,4 38,4 44,6 C inlet pressure 1,4 1,4 1,4 1,4 bar load kw G/E No. 2 Inlet temperature 34,4 34,6 37,1 38,3 C outlet temperature 39,6 38,6 42,8 39,2 C load kw G/E No. 3 Inlet temperature 33,6 33, ,8 C outlet temperature 34,8 35,7 37,1 38,7 C inlet pressure 0,8 0,8 0,8 0,8 bar load kw Main L.O. cooler inlet temperature 32,2 32,9 34,8 36,8 C outlet temperature 32,2 32,9 34,8 36,9 C inlet pressure 0,2 0,2 0,2 0,2 MPA Side 25 af 96
27 outlet pressure 0,14 0,14 0,14 0,14 MPA H.T. system M/E jacket cooling F.W pump 1 inlet pressure MPA outlet pressure MPA inlet temperature C outlet temperature C Load Amp M/E jacket cooling F.W pump 2 inlet pressure 0,6 0,6 0,6 0,6 MPA outlet pressure 0,46 0,46 0,46 0,46 MPA inlet temperature 70,9 70,6 72,2 71,9 C outlet temperature 73 71,9 73,6 73,8 C Load Amp M/E jacket F.W. preheater Inlet temperature 75,3 72, ,9 C outlet temperature 80,1 76,2 79,8 80,3 C inlet pressure bar outlet pressure bar Valve open/close 8V valve 61,5 open/close 14V Valve 64,8 open/close 15V Valve 28,4 open/close 41V Valve 29,9 open/close 150V Main engine Inlet temperature 73,3 72,9 73,4 73,4 C outlet temperature 73,1 72,7 73,4 73,3 C Inlet pressure bar outlet pressure 2,5 2,5 2,5 2,5 kgf/cm² Load kw Speed knts Torque NM Consumption g/kwh Fresh water generator Side 26 af 96
28 Inlet temperature C outlet temperature C Inlet pressure bar outlet pressure bar Energy consumption Gensets energy consumption number of gensets is running numbers consumption pr. day 2,43 2,39 2,63 2,64 tons Total electrical load pr. day kwh SFOC 257,4 256,74 257,4 251,4 g/ekwh L.O consumption Temp in 30,1 31,7 30,5 32,1 C Temp out 30,6 32,3 30,1 30,3 C Inlet pressure 0,06 0,046 0,058 0,058 MPA outlet pressure 0,05 0,038 0,044 0,044 MPA 6-17 oktober 2016 Kølevandssystem Condition Anchor Anchor Anchor Anchor Dato Beskrivelse Enhed Drawing no. Seawater temperature 28 27, ,7 C Engine room temperature C S.W. system Main C.S.W Pump 1 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Side 27 af 96
29 Main C.S.W Pump 2 Suction pressure MPA Delevery pressure MPA Temp C Load Amp Aux C.S.W Pump Suction pressure 0,02 0,03 0,03 0,03 MPA Delevery pressure 0,37 0,36 0,35 0,38 MPA Temp 27,9 27,8 26,2 36,6 C Load Amp Central F.W cooler 1 S.W temperature inlet 27,4 24,8 24,9 25,3 C S.W temperature outlet 23,2 27,4 27,8 27,9 C S.W Pressure inlet 2,6 2,5 2,5 2,7 bar S.W Pressure outlet bar Central F.W cooler 2 S.W temperature inlet C S.W temperature outlet C S.W Pressure inlet bar S.W Pressure outlet bar Dump cond/drain cooler S.W temperature inlet 30,7 30,1 31,3 31,4 C S.W temperature outlet 47,3 37,1 39,1 34,3 C Bypass cooler 60% 60% 60% 60% open/close 22V L.T. system Central cool F.W pump 1 Suction pressure 0 0 0,12 0,12 MPA Delevery pressure 0 0 0,3 0,3 MPA Temp ,9 26,9 C Load Amp Central cool F.W pump 2 Suction pressure MPA Delevery pressure MPA Temp C Side 28 af 96
30 Load Amp Central cool F.W pump 3 Suction pressure 0,06 0, MPA Delevery pressure 0,36 0, MPA Temp 29,8 29,4 0 0 C Load Amp Central F.W cooler 1 F.W temperature inlet 27,4 37,4 29,4 27,4 C F.W temperature outlet 26,2 26,6 27,6 26,5 C F.W Pressure inlet 2,2 2,2 2,2 2,2 bar F.W Pressure outlet 1,4 1,4 1,4 1,4 bar Central F.W cooler 2 F.W temperature inlet C F.W temperature outlet C F.W Pressure inlet bar F.W Pressure outlet bar Main engine air cooler inlet temperature 30 27,1 25,6 25,6 C outlet temperature 30 37,1 25,6 25,6 C L.T. system consumers G/E No. 1 Inlet temperature 27 28,8 28,1 28,2 C outlet temperature 30,2 35,8 35,4 29,5 C inlet pressure 1,2 1,2 1,2 1,2 bar load kw G/E No. 2 Inlet temperature 27 28,5 27,8 27,7 C outlet temperature 31,8 30,5 29,4 28,8 C inlet pressure 0,8 0,8 0,8 1 bar load kw G/E No. 3 Inlet temperature 27,3 26,8 26,8 27,8 C outlet temperature 33,4 28,3 27,4 33,6 C Side 29 af 96
31 inlet pressure 0,4 0,8 0,7 0,8 bar load kw Main L.O. cooler inlet temperature 27,1 28,1 26,2 26,4 C outlet temperature 27,2 28,1 26,2 26,4 C inlet pressure 0,2 0,2 0,2 0,2 MPA outlet pressure 0,12 0,14 0,14 0,14 MPA H.T. system M/E jacket cooling F.W pump 1 inlet pressure MPA outlet pressure MPA inlet temperature C outlet temperature C Load Amp M/E jacket cooling F.W pump 2 inlet pressure 0,6 0,6 0,6 0,6 MPA outlet pressure 0,46 0,46 0,46 0,46 MPA inlet temperature 63,2 59,4 59,5 60,9 C outlet temperature 63,8 60,6 60,3 62,3 C Load Amp M/E jacket F.W. preheater Inlet temperature 63,5 59,6 62,4 63,9 C outlet temperature 78,2 73,1 77,4 77,8 C Valve open/close 8V valve 60,9 open/close 14V Valve 59,9 open/close 15V Valve 28,2 open/close 41V Valve open/close 150V Main engine Inlet temperature 69,8 63,9 63,3 64,4 C outlet temperature 69,6 63,4 63,3 64,3 C Inlet pressure bar outlet pressure 2,5 2,7 2,6 2,5 kgf/cm² Load kw Side 30 af 96
32 Speed knts Torque NM Consumption g/kwh Fresh water generator Inlet temperature 67,1 63,5 63,4 64,7 C outlet temperature 51,3 52,4 51,8 46,4 C Inlet pressure 1,2 1,2 1,2 1 bar outlet pressure bar Energy consumption Gensets energy consumption number of gensets is running numbers consumption pr. day 2,69 3,45 2,87 2,73 tons Total electrical load pr. day kwh SFOC 261,3 252, ,2 g/ekwh L.O consumption Temp in 29,6 29,9 28,6 29,4 C Temp out 28,4 29,9 28,6 29 C Inlet pressure 0,048 0,06 0,04 0,06 MPA outlet pressure 0,038 0,05 0,04 0,05 MPA Side 31 af 96
33 Bilag 5 - Diesel fact Udklip fra Diesel Fact, 2/2015 side 2. Side 32 af 96
34 Bilag 6 - Main Central Colling FW system Side 33 af 96
35 Bilag 7 - Pumpe data Main C.S.W. Pump (SW pumper) Model DB 300 VIG1 Total head 23 M Capacity 930 m3/h Speed 1750 rpm Power 90 kw Date 2003,06 AUX C.S.W. pump (Havnepumpen) Model B200 VIC1 Total head 23 M Capacity 320 m3/h Speed 1750 rpm Power 37 kw Date 2003,06 Central C.F.W pump (LT pumper) Model B200 VIC1 Total head 25 M Capacity 450 m3/h Speed 1750 rpm Power 50 kw Date 2003,06 M/E Jacket C.F.W pump Model B125 VIC1 Total head 30 M Capacity 115 m3/h Speed 1750 rpm Power 19 kw Date 2003,06 Side 34 af 96
36 Bilag 8 - Mail korrespondance med Ole Flyvholm Side 35 af 96
37 Bilag 9 - Central Cooling Seawater system Side 36 af 96
38 Bilag 10 - AUX Central Cooling FW system Side 37 af 96
39 Bilag 11 - Motor data Main C.S.W. Motor (Motor til SW pumper) Model Polpar 2 Power 90 kw Voltage 440 Hertz 60 RPM 1765 Nom. Eff. 93% Amps. 142,7 Date 2003,05 IP IP44 AUX C.S.W. Motor (Motor til havnepumpe) Model HK205UR Polpar 2 Power 37 kw Voltage 440 Hertz 60 RPM 1765 Nom. Eff. 92% Amps. 62,8 Date 2003,04 IP IP44 Central C.F.W. Motor (Motor til LT pumper) Model MDBJ2S0406P Polpar 2 Power 50 kw Voltage 440 Hertz 60 RPM 1765 Nom. Eff. 92,50% Amps. 81,1 Date 2003,05 IP IP44 M/E Jacket C.F.W. Motor Model HK183JR201Z71 Polpar 21 Power 18.5 kw Voltage 440 Hertz 60 RPM 1765 Nom. Eff. 88,50% Amps. 33,2 Date 2003,04 IP IP44 Side 38 af 96
40 Bilag 12 - Mail korrespondance med Casper Side 39 af 96
41 Bilag 13 - Pump test records LT pumper Side 40 af 96
42 Side 41 af 96
43 Side 42 af 96
44 Side 43 af 96
45 Bilag 14 - Pump test records SW pumper AUX SW Pump Side 44 af 96
46 Side 45 af 96
47 Main SW pumps Side 46 af 96
48 Side 47 af 96
49 Side 48 af 96
50 Bilag 15 - Effekter afsat i varmeveksleren Der er i dette Excel ark regnet med en specifik varmekapacitet: C SW = 3930 og en massefylde på søvand på: ρ SW = 1025 kg m 3 Ud fra formlen: Q = m c t er det nu muligt at beregne effekten i køleren. De koloner markeret med rød anser vi for ugyldige, da der her er blevet kørt med en anden pumpe, eller backfluss gennem en af ferskvandskølerne. KJ kg C Condition Anchor Anchor Anchor Anchor Anchor Anchor Anchor Dato F.W cooler 1 (S.W) Inlet temp. [ C] Lukket Lukket Lukket Lukket Lukket Lukket Lukket outlet temp. [ C] Lukket Lukket Lukket Lukket Lukket Lukket Lukket difference temp. [ C] F.W cooler 2 (S.W) Inlet temp. [ C] 26,4 24,2 21,9 22,6 21,3 22,1 21,6 outlet temp. [ C] 29,4 27,4 26,1 28,6 26,9 28,7 28 difference temp. [ C] 3 3,2 4,2 6 5,6 6,6 6,4 Aux C.S.W Pump Suction pressure [MPA] 0,02 0,02 0,02 0,02 0,02 0,02 0 Delevery pressure [MPA] 0,4 0,4 0,4 0,4 0,39 0,39 0 difference pressure [MPA] 0,38 0,38 0,38 0,38 0,37 0,37 0 difference pressure [mvs] 38,8 38,8 38,8 38,8 37,7 37,7 0 Flow (aflæst) [m3/min] 0,3 0,3 0,3 0,3 0,85 0,85 0 Main C.S.W Pump 2 Suction pressure [MPA] ,08 Delevery pressure [MPA] ,48 difference pressure [MPA] ,4 difference pressure [mvs] ,8 Flow (aflæst) [m3/min] Effekt afsat i veksleren [kw] 60,42 64,448 84, ,84 319, , ,96 Side 49 af 96
51 Condition Anchor Anchor Anchor Anchor Anchor Anchor Anchor Dato F.W cooler 1 (S.W) Inlet temp. [ C] Lukket Lukket Lukket 22,4 25,3 24,1 23,6 outlet temp. [ C] Lukket Lukket Lukket 25,9 28,9 29,1 27,3 difference temp. [ C] ,5 3,6 5 3,7 F.W cooler 2 (S.W) Inlet temp. [ C] 25, ,6 27,2 Lukket Lukket Lukket outlet temp. [ C] 30,4 28,6 29,4 23,6 Lukket Lukket Lukket difference temp. [ C] 4,5 4,6 4,8-3, Aux C.S.W Pump Suction pressure [MPA] 0,08 0,08 0,08 0,07 0,07 0,07 0,07 Delevery pressure [MPA] 0,45 0,46 0,45 0,4 0,41 0,41 0,41 difference pressure [MPA] 0,37 0,08 0,37 0,33 0,34 0,34 0,34 difference pressure [mvs] 37,7 38,8 37,7 33,7 34,7 34,7 34,7 Flow (aflæst) [m3/min] 0,85 0,3 0,85 2,9 2,5 2,5 2,5 Main C.S.W Pump 2 Suction pressure [MPA] Delevery pressure [MPA] difference pressure [MPA] difference pressure [mvs] Flow (aflæst) [m3/min] Effekt afsat i veksleren [kw] 256,785 92, , , ,2 839, ,98333 Condition Anchor Anchor Anchor Anchor Anchor Anchor Dato F.W cooler 1 (S.W) Inlet temp. [ C] 25,8 25,6 27,4 24,8 24,9 25,3 outlet temp. [ C] 31,1 30,3 23,2 27,4 27,8 27,9 difference temp. [ C] 5,3 4,7 4,2 2,6 2,9 2,6 F.W cooler 2 (S.W) Inlet temp. [ C] Lukket Lukket Lukket Lukket Lukket Lukket outlet temp. [ C] Lukket Lukket Lukket Lukket Lukket Lukket difference temp. [ C] Aux C.S.W Pump Suction pressure [MPA] 0,07 0,07 0,02 0,03 0,03 0,03 Delevery pressure [MPA] 0,41 0,41 0,37 0,36 0,35 0,38 difference pressure [MPA] 0,34 0,34 0,35 0,33 0,32 0,35 difference pressure [mvs] 34,7 34,7 35,7 33,7 32,6 35,7 Flow (aflæst) [m3/min] 2,5 2,5 2 2,9 3,5 2 Main C.S.W Pump 2 Suction pressure [MPA] Delevery pressure [MPA] difference pressure [MPA] difference pressure [mvs] Flow (aflæst) [m3/min] Effekt afsat i veksleren [kw] 889, , ,92 506, , ,09333 Side 50 af 96
52 Bilag 16 - Infrarødt termometer Side 51 af 96
53 Bilag 17 Heat Balance Sheet Side 52 af 96
54 Side 53 af 96
55 Side 54 af 96
56 Side 55 af 96
57 Side 56 af 96
58 Side 57 af 96
59 Normal sea going with tank cleaning or heating Side 58 af 96
60 Normal sea going Side 59 af 96
61 Cargo unloading Side 60 af 96
62 Port condition Side 61 af 96
63 Bilag 18 - Brændstof rapport Bunkring Fuel Quality Report TORM ESTRID ( ) Antwerp 05/08/2016 Sample information has been collated from the vessel's bunker data form and sample bottle label. Sample No: Client: DL Torm Tech Div Cph Received by Lab: 09/08/2016 Grade Ordered: RMG380 Sulphur Grade: 3.5% max Quantity Supplied: M.T. Bunker Information Bunker Port: Antwerp Bunker Date: 05/08/2016 Fuel Supplier: Transcor Energy Barge: Hydrus Sample Location: Ship's bunker line Sample Seal Information Seal Condition: Intact Analysis Sample: / Supplier Sample: Vessel Sample: Marpol Sample: Courier Information DHL PAD Used: No DHL PAD Comments: Courier Airway Bill No.: Density (kg/m³@15 C) Viscosity (cst@50 C) Sulphur (%mass) Specification Supplier BDR Analysed sample Parameter Result Units Spec Limit Test Variance (±) Method Viscosity (50 C) cst@50 C max ISO 3104 Density kg/m³@15 C max 0.9 ISO CCAI 850 Index # ISO 8217:B Sulphur 2.04 % mass 3.50 max 0.18 ISO 8754 Flash Point >70.0 C 60.0 min ISO 2719 Acid Number 0.21 mg KOH/g ASTM D664 Total Sediment <0.01 % mass 0.10 max 0.06 ISO Micro Carbon Residue % mass max 1.00 ISO Pour Point -6 C 30 max 4 ISO 3016 Water 0.15 % vol 0.50 max 0.10 ISO 3733 Ash % mass max ISO 6245 Vanadium 133 mg/kg 300 max 30 IP 501 Side 62 af 96
64 Sodium 19 mg/kg IP 501 Aluminium plus Silicon 15 mg/kg 80 max 16 IP 501 Net Specific Energy MJ/kg ISO 8217:A Calcium 6 mg/kg IP 501 Zinc 2 mg/kg IP 501 Phosphorus 1 mg/kg IP 501 Aluminium 7 mg/kg IP 501 Silicon 8 mg/kg IP 501 Iron 23 mg/kg IP 501 Nickel 26 mg/kg IP 501 Magnesium <1 mg/kg IP 501 Lead <1 mg/kg IP 501 Compatibility 1 Spot # ASTM D4740 Injection 10 cst 142 C Injection 12 cst 135 C Injection 15 cst 126 C Injection 17 cst 122 C Injection 20 cst 116 C Injection 22 cst 113 C Minimum Pumping cst 33 C Chemical Contamination Green * result exceeds specification. Refer to your engine manufacturer's guideline for max/min alarm settings. Sample results are compared with the specification for RMG380 ISO 8217:2005. ONBOARD FUEL BLENDING IS NOT RECOMMENDED. Refer to your engine manufacturer's guidelines for max/min alarm settings. Engineering Notes Do you have enough sample bottles? If not, please refer to your instruction folder for supply details. Alternatively, contact the Intertek ShipCare Logistics Department at [email protected] or call Signed: Narinder Singh Reported By: Narinder Singh Report Date: 09/08/ Fuel Quality Report TORM ESTRID ( ) Antwerp 05/08/2016 Sample information has been collated from the vessel's bunker data form and sample bottle label. Sample No: Client: DL Torm Tech Div Cph Side 63 af 96
65 Received by Lab: 09/08/2016 Grade Ordered: DMA Sulphur Grade: 0.1% max Quantity Supplied: M.T. Bunker Information Bunker Port: Antwerp Bunker Date: 05/08/2016 Fuel Supplier: Transcor Energy Barge: Not Stated Sample Location: Ship's bunker line Sample Seal Information Seal Condition: Intact Analysis Sample: / Supplier Sample: Vessel Sample: Marpol Sample: Courier Information DHL PAD Used: No DHL PAD Comments: Courier Airway Bill No.: Density C) Viscosity C) Sulphur (%mass) Specification Supplier BDR Analysed sample Parameter Result Units Spec Limit Test Variance (±) Method Viscosity (40 C) cst@40 C ISO 3104 Density kg/m³@15 C max 0.9 ISO Cetane Index min ISO 4264 Sulphur % mass 0.10 max 0.01 ISO 8754 Flash Point >70.0 C 60.0 min ISO 2719 Acid Number <0.20 mg KOH/g ASTM D664 Micro Carbon Residue <0.01 % mass 0.30 max 0.06 ISO Cloud Point +6 C ISO 3015 Pour Point <-12 C 0 max 4 ISO 3016 Appearance Clear/Bright VISUAL Water <0.05 % vol ISO 3733 Ash <0.001 % mass max ISO 6245 Net Specific Energy MJ/kg ISO 8217:A Chemical Contamination Green * result exceeds specification. Refer to your engine manufacturer's guideline for max/min alarm settings. Sample results are compared with the specification for DMA ISO 8217:2005. ONBOARD FUEL BLENDING IS NOT RECOMMENDED. Side 64 af 96
66 Bilag 19 - Torm Estrid Bunkring Vessel Name Time Actual Delivery Date.Calendar Year TORM ESTRID (Multiple Items) Row Labels Delivered Qty Bunker PO Cost per Mton ALGECIRAS 1253, , CST 1109, DMA LSMGO 144, AMSTERDAM 1220, , CST 1126,9 269 DMA LSMGO 93, ANTWERP 1994, , CST 1127, LSMGO 81, , CST 450, DMA LSMGO 334, FUJAIRAH 2560, , CST 1378, , CST 1182, HUELVA 1328, , CST 1029, DMA LSMGO 299, JEDDAH 402, , CST 402,2 302 LAS PALMAS 149, , LSMGO 149, MARGATE 1486, , CST 1385, LSMGO 100,4 525 SALVADOR 300, , CST 300, SINGAPORE 2174, , CST 1318, Side 65 af 96
67 DMA LSMGO 147, , CST 708, SKAW 275, , DMA LSMGO 275, STAPELTON, NEW YORK 215, , DMA LSMGO 215, Grand Total 13361, Side 66 af 96
68 Bilag 20 Brændstofforbrug Bunkering Dato HFO MGO ,2 0 mt ,027 0 mt , ,4 mt ,957 mt ,941 81,922 mt ,9 93,787 mt , ,16 mt ,016 mt ,08 mt , ,134 mt ,01 0 mt ,382 0 mt ,808 0 mt , ,525 mt , ,209 mt Total 11520, , ,46 mt % HFO 86,2% % MGO 13,8% Side 67 af 96
69 Bilag 21 - Dagspris MGO og HFO Screenshot fra den 18/ Side 68 af 96
70 Bilag 22 - Valutakurs USD -> DKK Kurs fra den 18/ Side 69 af 96
71 Bilag 23 - Plate Cooler No. 1 Side 70 af 96
72 No. 2 Side 71 af 96
73 Bilag 24 - Pressostat Udklip af Main Central Colling FW system bilag 6. Side 72 af 96
74 Bilag 25 - Mail korrespondance med Gert Andersen Hej Gert Vi tænkte på om du kunne hjælpe med et par sprøgsmål til vores bachelor projekt. Vi er igang med at skrive et bachelorprojekt om energioptimering af kølevandssystemet ombord på Torm Estrid og er på nuværende tidspunkt igang med at lave nogle løsningsforslag på problemet. Har i nogle minimum grænse som el motorerne som tommelfingerregler max må køre ned til? Det er et 60 Hz 440 V el net de har ombord på dette skib. Vi har muligvis også et spørgsmål angående priser på en frekvensomformer og en styring som vi ønsker tilbud på senere hen, hvis det er noget i er interesseret i at give tilbud på. Venlig hilsen Morten Rauhe Fra: Gert Andersen <[email protected]> Dato: 17. november 2016 kl Til: Morten Rauhe <[email protected]> Hej Morten Jeg vil gerne hjælpe jer med de spørgsmål I har. Som en tomlefingerregel plejer vi at sige at man ikke køre under 50% af hastigheden. Hvis vi kommer under dette kan man risikere at motoren ikke kan køle sig selv mere og derved brander af. Ønsker man at køre langsommere vil jeg anbefalede at vi montere en ventilator på motoren. I skriver bare igen. Med venlig hilsen / Best regards Gert Mahon Andersen Technical Sales Manager Mob: [email protected] Tel: Fax: Web: Aut. Omron Electronics, Bonfiglioli samt CG Drives & Automation forhandler. Side 73 af 96
75 Bilag 26 - Beregning af drift punkt for LT pumpe Konstruktion af Anlægskarakteristik og beregning af driftspunkt i LT system For at kunne konstruere en anlægskarakteristik for LT pumperne har vi fundet et driftspunkt i databladet over pumperne. I dette datablad står der at pumperne har et driftspunkt på 25 mvs ved et flow på 450 m³/h hvilket vi har regnet med igennem rapporten. Ud fra disse oplysninger og da pumperne pumper i et lukket system kan vi nu konstruere en anlægs karakteristik. Anlægskarakteristikken startet i punkt 0,0 da LT systemet er et lukket system, og der derfor kun er en dynamisk løftehøjde. Ved hjælp at drift punktet for pumpen kan vi nu lave en anlægskarakteristik. Driftspunkt 1 Q 1 = 450 m3 h = 450 m3 /h 60 min/h H 1 = H dyn = 25 mvs K A = H 1 Q 2 = 25 7,5 2 = 0,444 = 7,5 m3 min Formel til beregning af alle punkter i anlægskarakteristikken: H = K A Q 2 Udregning af punkter: k 0,444 Q [m3/min] 0 0,75 1,5 2,25 3 3,75 4,5 5,25 6 6,75 7,5 8,25 H [mvs] 0 0,25 1 2,25 4 6, , , ,25 På næste side har vi konstrueret pumpe og anlægskarakteristikken. Driftspunkt 2 er det punkt pumpen minimum må regulere ned på, for at opretholde difference trykket på 1,5 bar hen over pumpen. Det ses på efterfølgende side, hvordan vi er kommet frem til det antal omdrejninger pumpen skal køre med ved dette driftspunkt. Side 74 af 96
76 Side 75 af 96
77 Bilag 27 Beregning af minimums flow Ved omdrejningsregulering reduceres flowet ved hjælp af formlen: Q 1 Q 2 = n 1 n 2 Da vi ved at pumpen minimum kan justeres ned til 1380 omdr/min, kan vi nu regne minimums flowet ved omdrejnings regulering af en af LT pumperne: n 1 = 1765 omdr min n 2 = 1380 omdr min Q 1 = 450 m3 h Q 2 = n 2 Q n 1 => Q 2 = = 351,8 m³/h Nødvendige flow i henhold til frekvensregulering: Beregning af flow i havn/anker situation: Da der kun er brug for et flow på 133,2 m³/h i havn/anker situation, er det nok at køre med pumpen på minimums flowet, hvor den levere 351,8 m³/h. Beregning af flow ved losning: I losse situationer er der brug for et flow på 526,4 m³/h, det er derfor i denne situation ikke nok at køre med en pumpe. I denne situation bliver man derfor nød til at parallelkoble to pumper, hvor af den ene levere 450 m³/h, mens den anden frekvensregulerede pumpe levere minimums flowet på 351,8 m³/h. Dette giver et samlet flow på 801,8 m³/h. Beregning af flow ved normal sejlads: Under normal sejlads er der behov for et flow på 478,2 m³/h, det er i dette tilfælde igen ikke nok med en enkel pumpe og det er derfor nødvendigt med parallelkobling af to pumper. I dette tilfælde er det nødvendigt at have en LT pumperne kørende som levere 450 m³/h samt den frekvensregulerede pumpe som levere 351,8 m³/h, for at opnå flowet. Dette giver et samlet flow på 801,8 m³/h. Side 76 af 96
78 Beregning af flow ved normal sejlads med tankrensning: Under normal sejlads med tankrensning er der behov for et flow på 796,4 m³/h, det er i dette tilfælde igen ikke nok med en enkel pumpe og det er derfor nødvendigt med parallelkobling af to pumper. I dette tilfælde er det nødvendigt at have en LT pumperne kørende som levere 450 m³/h samt den frekvensregulerede pumpe som levere 351,8 m³/h, for at opnå flowet. Dette giver et samlet flow på 801,8 m³/h. Side 77 af 96
79 Bilag 28 - Tilbud 1 fra CS Electric Hej Gert Vi har nu udarbejdet et løsningsforslag med en frekvensomformer og temperatur styring af en pumpe, vi ønsker derfor et tilbud på følgende: 1 stk 50 kw frekvensomformer 2 stk temperatur transmittere med et måle område fra 0-60 grader en PLC som kan styre denne frekvensomformer ved hjælp af det analoge signal fra disse to temperatur transmittere. Derudover kræves der en programering af denne PLC, så den kan regulere ved hjælp af et sætpunkt fra den ene transmitter og bruge den anden transmitter som feedforward regulering inden afvigelsen bliver for stor. Er det noget i kan give en overslags pris på? Venlig hilsen Morten Rauhe :) Fra: Gert Andersen <[email protected]> Dato: 28. november 2016 kl Til: Morten Rauhe <[email protected]> Hej Morten Det vil jeg gerne hjælpe jer med. Den pris jeg kommer med er en listepris og med baggrund i denne mail. Overslagsprisen indeholder følgende hardware. 1 stk. 55 Kw FDU48 55 kw IP 54 Mains IT; Coated boards, PTC/PT 100 Marine Approved Profi-net 2 stk. Temp. -20/125 gr. C 4-20 ma 1 stk. ECOPAC control system incl. HMI Installation kit. (estimated) Electrical Documentation Special Software (PLC and HMI) Overslagspris på alt dette : ,- Dertil skal I regne med at der kommer en installationsomkostning. Jeg kunne godt tænke mig at se en skitse over jeres system hvor I ind tegner div. sensor osv Kun fordi at jeg ikke helt er enig i at det er denne model I skal gå efter. Med venlig hilsen / Best regards Gert Mahon Andersen Technical Sales Manager Side 78 af 96
80 Bilag 29 - Bypass ventil Udklip af Main Central Colling FW system bilag 6. Side 79 af 96
81 Bilag 30 Datablad ny pumpe Side 80 af 96
82 Side 81 af 96
83 Side 82 af 96
84 Side 83 af 96
85 Side 84 af 96
86 Side 85 af 96
87 Bilag 31 Beregning af flow ved parallelkoblede LT pumper Vi vil herunder vise hvor stort et flow, som er nødvendigt for en ny pumpe i LT systemet, for fortsat at kunne levere det nødvendige flow. Havne situation: Under havne ophold er der brug for et flow i LT systemet på 133,2 m³/h. Dette flow kan opnås ved at have en pumpe som levere en flow på 133,2 m³/h. Cargo unloading: Under losseoperationer er der behov for et flow på 526,4 m³/h. Dette flow kan opnås ved hjælp af parallelkobling af to pumper, hvor pumpen med fast omdrejningstal levere et flow på 450 m³/h, mens den parallelkoblede pumpe leverer resten. Det vil sige at den nye parallelkoblede pumpe i dette tilfælde skal levere: Normal sejlads: 526,4 m3 h 450 m3 h = 76,4 m³/h Under normal sejlads er der behov for et flow på 478,2 m³/h. Dette flow kan opnås ved hjælp af parallelkobling af to pumper, hvor pumpen med fast omdrejningstal levere et flow på 450 m³/h, mens den parallelkoblede pumpe leverer resten. Det vil sige at den nye parallelkoblede pumpe i dette tilfælde skal levere: Normal sejlads med tankrensning: 478,2 m3 h 450 m3 h = 28,2 m³/h Under normal sejlads med tankrensning er der brug for et flow på 796,4 m³/h. Dette flow kan opnås ved hjælp af parallelkobling af to pumper, hvor pumpen med fast omdrejningstal levere et flow på 450 m³/h, mens den parallelkoblede pumpe leverer resten. Det vil sige at den nye parallelkoblede pumpe i dette tilfælde skal levere: 796,4 m3 h 450 m3 h = 346,4 m³/h Side 86 af 96
88 Flowet på 346,4 m³/h er langt større end de andre flow, vi vælger derfor at sige at dette flow ikke kan dækkes ved hjælp af en ny pumpe, men blot bruge de eksisterende pumper til at dække dette behov. Det kan derfor nøjes med en pumpe, som levere et flow på 133,2 m³/h ved en trykhøjde på mindst 15,3 mvs (1,5 bar). Forskellen mellem det mindste og det største flow, ved mulighed for parallelkobling: 133,2 m³/h 28,2 m³/h = 105 m³/h Side 87 af 96
89 Bilag 32 - Lastekonditoner 2015 Side 88 af 96
90 Bilag 33 - Tilbud løsningsforslag 2 Komponent antal pris Pris i alt Reduktionsflanger ø139,7 ø , ,- STÅLFLANGE 139,7 TN , ,- Grundfos pumpe , ,- Inspektions certifikat , ,- Fragt omkostninger ,- 5000,- div. (pakninger, bolte, jern, elektroder) ,- 1000,- Røntgen af svejsninger inkl. rapport , ,- Nye tegninger til klassen ,- 5000,- Timeløn for 1 Svejser inkl. ude tillæg , ,- Pris i alt ,- Tilbud fra andre leverandører er foretaget enten via telefonopkald eller på baggrund af faglig erfaring. Tilbud fra Grundfos DK A/S Side 89 af 96
91 Bilag 34 - Drøvle forsøg open / close open / close Open / close Open / close Open / close Open / close Open / close F.W. cooler 1 open open open open open open open F.W cooler 2 close close close close close close close AE 1 open open open open open open open AE 2 open open open open open open open AE 3 open open open open open open open L.O cooler open close close close open open close hyd. Oil cooler close close close close close close close Aircon condensator 1 open open open open open open open Aircon condensator 2 close close close close close close close Air cooler 50% open close close open open close close Main air compressor 1 open open open open open open open Main air compressor 2 open open open open open open open service air compressor open open open open open open open S/T L.O. Cooler open close close close close open open Prov. Ref condenser 1 close close close close close close close Prov. Ref condenser 2 60% open 60% open 60% open 60% open 60% open 60% open 60% open H.P.P Engine 1 open close open open open open open H.P.P Engine 2 open close open open open open open H.P.P Engine 3 open close open open open open open H.P.P Engine 4 open close open open open open open C.F.W Pump no suction pressure 0,12 MPA 0,12 MPA 0,12 MPA 0,12 MPA 0,12 MPA 0,12 MPA 0,12 MPA discharge pressure 0,3 MPA 0,44 MPA 0,42 MPA 0,33 MPA 0,3 MPA 0,33 A 0,41 MPA difference pressure 0,18 MPA 0,32 MPA 0,30 MPA 0,21 MPA 0,18 MPA 0,21 MPA 0,29 MPA Load 82 A 75 A 77 A 80 A 82 A 80 A 78 A Side 90 af 96
92 Bilag 35 - Udklip af voyage plan 2015 Side 91 af 96
93 Bilag 36 - Beregning af driftspunkt for SW pumper Konstruktion af Anlægskarakteristik og beregning af driftspunkt i SW system For at kunne konstruere en anlægskarakteristik for SW pumperne har vi fundet et driftspunkt i databladet over de store SW pumper. I dette datablad står der at pumperne har et driftspunkt på 23 mvs ved et flow på 930 m³/h hvilket vi har regnet med igennem rapporten. Da pumperne pumper i et åbent system er det nødvendigt både at vide den statiske og dynamiske løftehøjde i systemet. Den statiske løftehøjde i dette system er dog 0 mvs, da indløb og udløb fra pumpen er i samme højde og den statiske løftehøjde bliver derfor elemineret. Dette anlæg kan derfor ses som et lukket anlæg og man kan derved bruge affinitetsligningerne. Ved hjælp af drift punktet for pumpen kan vi nu lave en anlægskarakteristik. Driftspunkt 1 Q 1 = 930 m3 h = 930 m3 /h 60 min/h H stat = 0mVs H dyn = 23 mvs = 15,5 m3 min H 1 = H dyn + H stat = 23mVs + 0mVs = 23 mvs K A = H 1 Q 2 = 23 15,5 2 = 0,0957 Formel til beregning af alle punkter i anlægskarakteristikken: H = K A Q 2 Udregning af punkter: k 0,0957 Q [m3/min] 0 1,5 3 4,5 6 7,5 9 10, , ,5 18 H [mvs] 0 0,22 0,86 1,94 3,45 5,39 7,75 10,55 13,79 17,45 21,54 26,06 31,02 På næste side har vi konstrueret pumpe og anlægskarakteristikken. Side 92 af 96
94 Driftspunkt 2 er det punkt pumpen minimum må regulere ned på, for at opretholde difference trykket på 1,7 bar hen over pumpen. Det ses på denne side, hvordan vi er kommet frem til det antal omdrejninger pumpen skal køre med ved dette driftspunkt. Side 93 af 96
95 Bilag 37 - Beregning af flow Flow for AUX pumpen: Densitet søvand = 1025 kg/m3 Flow som Aux pumpen levere = 320 m3/h 320 m 3 /h 1025 kg/m 3 = 91, 1 kg 3600s/h s Nødvendige flow ved normal sejlads: C SW = 0,94 kcal kg kj 4,19 = Csw = 3,936 kj/kg C kcal Effekt forbrug ved dette scenarie = Q = 8664 kw Max temeratur = t2 = 43 Gennemsnitstemperatur havvand = t1 = 24,5 Densitet søvand = 1025 kg/m3 Q = m c (t 2 t 1 ) 8664 kw = m 3,936kJ/kg C (43 C 24,5 C) = 119 kg/s 119 kg s 3600 s h 1025 kg m 3 = 418 m3 h Side 94 af 96
96 Nødvendige flow ved normal sejlads og tankrensning eller opvarmning af lasten: Csw = 3,936 kj/kg C Effekt forbrug ved dette scenarie = Q = 8664 kw Max temeratur = t2 = 43 Gennemsnitstemperatur havvand = t1 = 24,5 Densitet søvand = 1025 kg/m3 Q = m c (t 2 t 1 ) kw = m 3,936 (43 C 24,5 C) = 151 kg/s 151 kg s 3600 s h 1025 kg m 3 = 530 m3 h Side 95 af 96
97 Bilag 38 - Tilbud SW løsningsforslag Hej Gert Jo jeg fik en mail mandag aften, men dette er en pris på SW systemet som jeg ønsker, hvor det andet var til FW systemet. Vi har nu udarbejdet et løsningsforslag med en frekvensomformer og temperatur styring af en af søvandspumperne, vi ønsker derfor et tilbud på følgende: 1 stk 90 kw frekvensomformer 1 stk temperatur transmittere med et måle område fra 0-60 grader en PLC som kan styre denne frekvensomformer ved hjælp af det analoge signal fra denne temperatur transmittere. Derudover kræves der en programering af denne PLC, så den kan regulere ved hjælp af et sætpunkt fra den ene transmitter. Kan man læse om dette ECOPAC system på jeres hjemmeside? Vh Morten Rauhe Fra: Gert Andersen <[email protected]> Dato: 30. november 2016 kl Til: Morten Rauhe <[email protected]> Hej Morten Okay. Men hvis I ønsker at regulere på FW. Skal I være opmærksom på hele varmebalancen i systemet samt hvor mange forbruger vi skal holde øje med. Et godt bud på et overslagspris, er nok stadig som skrevet i min mail ,- Her fylder SW nok 40% af prisen. Med venlig hilsen / Best regards Gert Mahon Andersen Technical Sales Manager Side 96 af 96
ENERGIOPTIMERING AF KØLEVANDSSYSTEM
ENERGIOPTIMERING AF KØLEVANDSSYSTEM Indhold Titelblad... 3 Forord... 4 Tak... 4 Abstract... 5 Indledning... 6 Metodeafsnit... 8 Pareto-analyse... 9 Boiler/kedlen... 11 Generator Engine... 12 Airconditionkompressoren...
Bilagsrapport. Nikolai Lyngsø og Lasse Juul Madsen Fredericia Maskinmesterskole Side 0 af 29
2018 Bilagsrapport Nikolai Lyngsø og Lasse Juul Madsen Fredericia Maskinmesterskole 24-05-2018 Side 0 af 29 Indholdsfortegnelse Bilag 1: Projekt skabelon... 2 Bilag 2: Udklip fra ISO standard 8861:1998
Energioptimering ved hjælp af spildvarme til opvarmning M/V SIA. Bilag. Jens Lund Pedersen M - TECH OFFSHORE.
25-05-2018 Energioptimering ved hjælp af spildvarme til opvarmning M/V SIA Bilag Jens Lund Pedersen M - TECH OFFSHORE Side 1 af 29 Indhold Projektskabelon... 4 Handlingsplan... 5 Bilag 1. SIA track record...
Reduktion af emissioner og driftsomkostninger i et større rederi. Chief Specialist Jakob Buus Petersen
Reduktion af emissioner og driftsomkostninger i et større rederi Chief Specialist Jakob Buus Petersen Miljø og omkostningsbesparelser PAGE 2 : Ship Engineering New-building projects Engine Electrical Hull
Energioptimering. - Brug af udstødningsgas fra hjælpemotorer BILAG. Til bachelorprojekt af: Anders Bjarnø Rasmussen V10889
Energioptimering - Brug af udstødningsgas fra hjælpemotorer BILAG Til bachelorprojekt af: Anders Bjarnø Rasmussen V10889 Indholdsfortegnelse 1 - Datablad for heatoliepumpe... 2 2 - Smøreskema og datablad
Lars Pedersen Januar 2013
MAERSK SUPPLY SERVICE Bilagsrapport Energioptimering af kølevandssystem Lars Pedersen Januar 2013 Titelblad Forfatter: Rapportens Titel: Lars Pedersen Bachelor projekt 2012 - Optimering af kølevandssystem
Supermarkeder og Smart Grid muligheder for fleksibelt elforbrug
Supermarkeder og Smart Grid muligheder for fleksibelt elforbrug Torben Funder-Kristensen Refrigeration and Air Conditioning Controls 1 Department (slide master) www.danfoss.com Agenda Cold Food Chain Trends
Simulator : Koldt skib (opstart af hjælpe DG)
Simulator : Koldt skib (opstart af hjælpe DG) MD70. Electrical power plant. Emergency generator skal startes op, det kan gøres ved hjælp af batteri eller håndkraft for at få EL til at drive fuell systemet
Energioptimering på søvandskølesystem. Bilagsmappen
Energioptimering på søvandskølesystem Bilagsmappen Amar Al-Karradi 10/3/2014 Indholdsfortegnelse Bilag 1:Nødvendige elektrisk effekt.... 2 Bilag 2: Ship particulars.... 3 Bilag 3: Søvandskølesystem...
M/S SEAWORKER. Support, Transport, Diving and Work Vessel. Supply, crew support, towing, crane and survey functions
M/S SEAWORKER Support, Transport, Diving and Work Vessel Supply, crew support, towing, crane and survey functions The Vessel is designed to work to both fixed structures, platforms and floating units.
EGR, SCR og kombineret EGR og SO X scrubber
Partnerskab for grøn skibsfart Emissionsteknologi på to-takts diesel motorer EGR, SCR og kombineret EGR og SO X scrubber Disclaimer All data provided on the following slides is for information purposes
Green Passenger Ferries
- Your professional maritime partner Faaborg Værft A/S Værftsvej 7, DK-5600 Faaborg, Tlf: +45 62 61 21 10 www.faaborg-vaerft.dk, [email protected] Sjövägen delivered to Ballerina AB located in Stockholm,
Samproduktion af varme og køling er oplagt til LT fjernvarme. DE Application manager Charles W. Hansen Grundfos
Samproduktion af varme og køling er oplagt til LT fjernvarme DE Application manager Charles W. Hansen Grundfos Fælles energicentral Grundfos og Gues idriftssat 2012 3 kølemask./varmepumper Proceskøling
SP40G001 40GKX GMC. Split system "Global Cassette" indoor unit. Spare parts 40GKX GKX
SP0G00 0GKX GMC Split system "Global Cassette" indoor unit Spare parts 0GKX 0-08-0 0GKX 08-08-05-060 0GKX 0-08-0 Split system "Global Cassette" indoor unit (Without electric heater) 8 7 9 6 5 0 5 6 7 8
Bilagsmappe til projektet
Bilagsmappe til projektet 2015 Indholdsfortegnelse Bilag 1 Data på fremdriftsmaskineriet/dieselgeneratorer... 2 Bilag 2 Skibets elektriske kedel... 3 Bilag 3 Tabel over timetal på motorer hos Stril Mariner
Gastekniske dage 15-16. Maj 2012
Gastekniske dage 15-16. Maj 2012 -Varierende gaskvalitet og styring. Steffen Møller Wärtsilä Danmark Disposition for indlæg. Disposition: -Kort om Wärtsilä -Wärtsilä gasmotorer i Danmark -Variation i gaskvaliteten
Niels Hjørnet Yacht Design Yacht Design. Niels Hjørnet Yacht Design
Niels Hjørnet Yacht Design Energieffektiva färjor Røde tal på bundlinjen 2011 Egholm færgen: -5284200,- DKK Fursund Færgeri: -210864,- DKK Thyborøn-Agger færgen: -2200000,- DKK Mors-Thy færgefart: -5086075,--
Semco Maritime - Vækst under vanskelige vilkår. Offshoredag 2009 Vice President Hans-Peter Jørgensen
Semco Maritime - Vækst under vanskelige vilkår Offshoredag 2009 Vice President Hans-Peter Jørgensen Agenda Semco Maritime forretningen Vækst via internationalisering Fremtidig vækststrategi Konsekvenser
Anbefaling af et ballastvand rensningsanlæg til Esbern Snare L17 - Bilagsmappe
F R E D E R I C I A M A S K I N M E S T E R S K O L E Anbefaling af et ballastvand rensningsanlæg til Esbern Snare L17 - Bilagsmappe Udarbejdet af: Saad Sufian Barzanji G20132021 Danni Christiansen EES1302016
Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Elektrisk aktuator Electric actuator Tekniske data Technical data
Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001
Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001 Ls venligst denne instruktions manual igennem inden brug af produktet Thank you for purchasing our product. This smart unit is not
Skibsteknisk Selskab Røggasemissioner fra skibsfart - før, nu og i fremtiden
Skibsteknisk Selskab Røggasemissioner fra skibsfart - før, nu og i fremtiden Skibsfartens udfordring vedrørende CO 2 - hvad sker der i IMO? v/afdelingschef Hans Henrik Petersen Danmarks Rederiforening
Nærskibsfart med bundlinieeffekt: Klima og miljø. Hans Otto Kristensen. [email protected]. Tlf: 45 25 13 95 alt. 40 45 90 20
Nærskibsfart med bundlinieeffekt: Klima og Hans Otto Kristensen [email protected] Tlf: 45 25 13 95 alt. 4 45 9 2 Sidste nyt vedr. TEMA 21 ang. lastbiler Effekt og fartafhængighed for skibe Baggrund for DTU
Ecodesign direktivet. Ventilationsdagen 2013. Projektleder Jørgen Føns Nielsen Institute Manager Henning Grønbæk
Ecodesign direktivet Ventilationsdagen 2013 Projektleder Jørgen Føns Nielsen Institute Manager Henning Grønbæk Ecodesign direktiver Ecodesign direktivet (2009/125/EF) er paraply over en række forordninger
Optimering af kølevandssystem på Clipper Marlene
Optimering af kølevandssystem på Clipper Marlene Marlene Poulsen Bachelorprojekt December 2016 Titelblad Titel: Optimering af kølevandssystem Problemformulering: Hvor stor en besparelse vil der kunne opnås
AC-Sun. Nyt koncept for klimaanlæg. www.ac-sun.com. Solar Thermal AC
Solar Thermal AC Nyt koncept for klimaanlæg www.ac-sun.com Virksomhedsprofil AC-Sun blev etableret som et selskab sidst i 2005 med den vision og formål at udvikle en revolutionerende ny generation af klimaanlæg
WIO200A INSTALLATIONS MANUAL Rev Dato:
WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of
Montagevejledning RIOpanel Integra
Montagevejledning RIOpanel Integra Indholdsfortegnelse Tekniske data...3 Montage af konvektor...3 El-installation...4 Styring af vand...4 Principskitse for tilslutning...5 Vedligeholdelse...6 Termostatstyring
Slot diffusers. Slot diffusers LD-17, LD-18
LD-17, LD-18 Application LD-17 and LD-18 are designed for supply of cold or warm air in rooms with a height between. m and 4 m. They allow easy setting of air deflectors for different modes of operation
Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper
Billigere og bedre varme til virksomheder Samsung PAC og Big Ceiling varmepumper Til STOR glæde Nye varmepumper til store rum baner vejen for besparelser og et bedre indeklima. Også i støvede omgivelser.
Bilags Mappe AUTOMATISK REVERSERING AF SPILDEVANDSPUMPER. Kenneth Marquardsen E
Bilags Mappe AUTOMATISK REVERSERING AF SPILDEVANDSPUMPER Kenneth Marquardsen E20141030 Indhold Projektskabelon... 2 Danva Benchmarking side 50. vand i tal 2016. Bilag. 1... 4 Pumpedata Gorman-Rupp. Bilag.
5-modetest på rullefelt
5-modetest på rullefelt Stamdata Projekt Archimedes Køretøj Scania Type Omnilink Motor DC 929 Reg. nr.: AW 88543 Euroklasse Euro 4 - EEV Emissionsreducerende udstyr n.a. Brændstof B0 Testdato 23-09-2010
ventilationsanlæg hos Lindø Industripark A/S
27-05-2016 Optimering af ventilationsanlæg hos Lindø Industripark A/S Bilagsmappe - FMS Navn: Steffen Møller Studie nr.: Indhold Bilag 1 - Projektskabelon... 2 Bilag 2 - Måling af volumenstrømme... 3 Bilag
Metal Oxide Varistor:TVM-B Series
Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction
www.svovlbrinte.dk MeasureStar Hjælp til beskyttelse af dit kloaksystem
MeasureStar Hjælp til beskyttelse af dit kloaksystem H 2 S Problem i kloaksystemet Produktionen og frigivelsen H 2 S gas i spildevandsystemer er ansvarlig for mange klager over lugt. Dog er destruktionen
PILLE PRESSE. 1 of 8. Salg & Service PE Maskiner Ans ApS Søgade 9 DK-8643 Ans By Tlf. +45 8687 0535 Fax +45 8687 0776 www.pemaskiner.
PILLE PRESSE Lav dine egne piller! N-MICRO pellet machine is the easiest way to Pellet. N-MICRO has been projected and developed properly for home and small pellet production, so every carpenter, farmer
Produkt information skal være med hvert produkt.
Henrik Vogensen Vølund Varmeteknik 1. December - 2015 Ansvar for importør/producent (LOT1 og LOT2) fra d 26. september 2015 Der skal medfølge et energi mærke til hver produkt/pakke som viser energiklassen.
Energieffektivisering i industrien
Energieffektivisering i industrien Brian Elmegaard Sektion Termisk Energi DTU Mekanik Teknologisk Institut Århus 2. Marts 2015 Indhold Potentielle besparelser Udnyttelse af overskudsvarme Analyseværktøjer
Hvis dette kunne have jeres interesse vil jeg meget gerne være behjælpelig med yderlig information og evt. tilbud.
Dato: 06-2005 Hermed fremsendes uopfordret en brochure mappe med vores udstyr til måling af brændstof forbrug om borde på skibe. Jeg håber at i lige har tid til at gennemse det medsendte. Systemet har
Datablad: Nature Impact Roof modul
1 Datablad: Nature Impact Roof modul Modul: Modulmål: 535 X 405 mm. Højde grundmodul: 40 mm. Højde vækstlag: ca. 6 cm. Total byggehøjde: ca. 6 cm + planter Vægt fuld vandmættet: 45 kg./m 2. Vandtilbageholdelse:
CBH - Aktiv Kølebaffel til synlig installation på væg under loft. Halton CBH. Aktiv Kølebaffel til synlig installation på væg under loft
Halton CBH Aktiv Kølebaffel til synlig installation på væg under loft Kombineret køle-, varme- og tilluftsarmatur for synlig installation under loft. Velegnet til hotelværelser og rum med høje krav til
Our activities. Dry sales market. The assortment
First we like to start to introduce our activities. Kébol B.V., based in the heart of the bulb district since 1989, specialises in importing and exporting bulbs world-wide. Bulbs suitable for dry sale,
Maritime Partenariate Scandinavia
Maritime Partenariate Scandinavia Poul Knudsgaard Vice President (Site Manager & Head of Production Frederikshavn, Head of PrimeServ Four-Stroke Denmark) PrimeServ MAN Diesel Poul Knudsgaard MAN Diesel
Navn: MUB 025 355EC DK varenr.: 32110 Version: 90 luftstrøm
MUB 25 355EC-DK varenr. 3211 Document type: Product card Document date: 212-6-29 Generated by: Systemair online katalog Version: 9 luftstrøm Beskrivelse 1 % regulerbar Indbygget elektronisk motorbeskyttelse
Bilagsmappe RØGPROBLEMER I TOMGANG PÅ BAYARD KLASSEN
Bilagsmappe RØGPROBLEMER I TOMGANG PÅ BAYARD KLASSEN Mogens Ebsen E20122067 Michael Jørgensen E20122048 FREDERICIA MASKINMESTERSKOLE 11/12-2015 Indhold Bilag 1 Projektskabelon... 4 Bilag 2 Installationstegning
Bachelorprojekt 2012 Optimering af kølevandssystem. Januar 2013 Aarhus Maskinmesterskole Lars Pedersen
Bachelorprojekt 2012 Optimering af kølevandssystem Januar 2013 Aarhus Maskinmesterskole Lars Pedersen Titelblad Forfatter: Lars Pedersen Rapportens Titel: Bachelor projekt 2012 - Optimering af kølevandssystem
Industrial Internet & Real-time Operational Intelligence i forsyningsindustrien
Industrial Internet & Real-time Operational Intelligence i forsyningsindustrien DATO 28/01/2016 Børsnoteret Swedish Stock Exchange Grundlagt 1986, 30 års jubilæum, 110+ medarbejdere - distributør - Nordeuropa
HPW varmepumpe væske-vand
HPW varmepumpe væske-vand Sammendrag Geotermisk varmepumpe Siemens PLC kontroller, forenklet regulator Intern softstart for enfasede enheder; regulerings funktion El-varme er valgfri Scroll kompressor;
Kompetanceudviklingsnetværk for Mikrobryggerier Kursus i El-forbrug og -besparelser
Den Skandinaviske Bryggerhøjskole The Scandinavian School of Brewing Kompetanceudviklingsnetværk for Mikrobryggerier Kursus i El-forbrug og -besparelser Axel G. Kristiansen og Kim L. Johansen Den Skandinaviske
Marine-Generator Prisliste 2011
Marine-Generator Prisliste 2011 Gertsen & Olufsen Savsvinget 4 2970 Hørsholm Tel.:+45 45763600 Danmark www.g-o.dk.net [email protected] Side 1: Side 2: Side 3: Side 4: Side 5: Side 6: Side 7: Panda 5000i - Panda
Novozymes Miljø rapportering Transport 25/03/2011
Novozymes Miljø rapportering Transport 2 Agenda: 1. Historik 2. Erfaringer på den hårde måde 3. Forsøg på ensretning 4. Data indsamling 5. Eksempler på intern information. 6. Næste opgave(r) 3 Peter Hansen
BILAG TILHØRENDE OPTIMERING AF MASKINRUMSVENTILATION MORTEN STRANDBY CHRISTENSEN - A15514
BILAG TILHØRENDE OPTIMERING AF MASKINRUMSVENTILATION MORTEN STRANDBY CHRISTENSEN - BACHELORPROJEKT DECEMBER 2018 - AARHUS MASKINMESTERSKOLE Indholdsfortegnelse BILAG 1 - DIESEL ENGINE ACCEPTANCE TEST RECORD...
Energioptimering af søvandspumpen til chiller-anlægget
2015 Energioptimering af søvandspumpen til chiller-anlægget BACHELORPROJEKT OMBORD PÅ IVER HUITFELDT NIKOLAJ KRISTENSEN JONAS NIELSEN Titelblad Titel: Energioptimering af søvandspumpen til chiller-anlægget
Tiltag for kontinueret drift af skruekompressorer på Styropack a/s
Tiltag for kontinueret drift af skruekompressorer på Styropack a/s Bilagshæfte til bachelorprojekt Martin Kempka Madsen Indhold Bilag 1... 3 Projektskabelon... 3 Bilag 2... 7 Dybdeinterview med Erling
Brugsanvisning. for. Oliebrænder DOMESTIC D-3 / D-4 VVS-EKSPERTEN A/S, BLÆSBJERGVEJ 54, 8722 HEDENSTED TLF. 75890303 FAX. 75890709
Brugsanvisning for Oliebrænder DOMESTIC D-3 / D-4 VVS-EKSPERTEN A/S, BLÆSBJERGVEJ 54, 8722 HEDENSTED TLF. 75890303 FAX. 75890709 WWW.VVS-EKSPERTEN.DK - 1 - Bemærk! I Danmark er brænderen fra fabrikken
Undersøgelse af danske institutters og firmaers muligheder for at servicere danske virksomheder inden for typeprøvning af legale måleinstrumenter
Undersøgelse af danske institutters og firmaers muligheder for at servicere danske virksomheder inden for typeprøvning af legale måleinstrumenter Rapport nr.: CLM 014A/2003 19. september 2003 DELTA Dansk
Bilagshæfte: Konsekvenser af strengere krav til anvendt brændolie
Bilagshæfte: Konsekvenser af strengere krav til anvendt brændolie En undersøgelse af konsekvenser ved en eventuel stramning af gældende miljøkrav for sejlads i grønlandsk farvand. Forfatter: Studienummer:
5-24 TALJER, KRANER & SPIL / HOISTS, CRANES & WINCHES
-24 TALJER, KRANER & SPIL / HOISTS, CRANES & WINCHES Kompakt elektrisk kædetalje til løft fra 63 til.000. - Løftekapacitet 63 til.000. - Standard løftehøjde 4 m. - Kontrolkabel 3 m. - To løftehastigheder.
Modulopbyggede GENERATORANLÆG. - og alt, hvad dertil hører... KVA Diesel ApS Borrisvej 10, Astrup DK-6900 Skjern
Modulopbyggede GENERATORANLÆG - og alt, hvad dertil hører... KVA Diesel ApS Borrisvej 10, Astrup DK-6900 Skjern Tel. (+45) 9736 4111 Fax (+45) 9736 4013 [email protected] www.kva-diesel.dk Diesel generatoranlæg
Svend Erik Mikkelsen, COWI
CITIES Workshop, 6 April 2018, DTU Demonstration of supply systems for heating, cooling and hot water with PVT - solar collectors with build-in PV - heat pump and battery storage Svend Erik Mikkelsen,
Standard 2-takt dieselmotor med turbo og intercooler
Standard 2-takt dieselmotor med turbo og intercooler Deffinitioner M 10 6 Atmosfærisk luft egenskaber (midlertidig) c p 1010 c kgk v 719.2 kgk c p κ 1.404 R c i c p c v 290.8 v kgk Hentet fra EES - T_1
Hudevad P200. Technical datasheet
Technical datasheet Key benefits Low, streamlined design Ideal in front of glazing to prevent cold draughts Available in two depths For high flexibility in usage Historical Kundenedfald Grøn energi Flat
LAD NATUREN KOMME INDENFOR
LAD NATUREN KOMME INDENFOR NOVEMBER 2015 2 TX KOMFORT Decentral ventilation med en kapacitet på 250 til 1000 m³/h, kan anvendes følgende steder: skoler kontorer mødelokaler kantiner institutioner pavilloner
Kondenseringsaggregater OPTYMA PLUS Oversigt over modeller
Oversigt over modeller Kondenseringsaggregater OPTYMA PLUS Oversigt over modeller OPTYMA PLUS Fuldt udstyret kondenseringsaggregater til fast installation Forstærket konstruktion Forberet til installation
Umiddelbart er der ingen tekniske argumenter for at placere store møller på land frem for mindre møller. Dette skyldes flere faktorer, f.eks.
Fra: Finn Alsgren [mailto:[email protected]] Sendt: 18. juni 2012 13:23 Til: Arne Graae Jensen Cc: Bruno Andersen Emne: FW: Godkendt dansk 750 kw mølle - Kan leveres som ny - Kan holdes under 80m
V1903-TV ( ) V2203-TV ( )
R Diesel Engine SERVICE PARTS LIST for V90-TV (-00) V0-TV (-00) Tier Beginning With Serial Number A000 --0 Rev B SERVICE PARTS LIST DIESEL ENGINE V90-TV (-00) V0-TV (-00) Tier Beginning With Serial Number
Spare parts ASC 5300 G V5
Front view ASC 5300 G Process display Art.Nr.:4441600088 LP Gauge Art.Nr.:4440600221 Cover gauge group Art.Nr.:4443900278 Printer ASC G-Version Art.Nr.:4441600178 Paper for printer ASC Art.Nr.:4445900088