Proportional pressure regulators VEAA

Relaterede dokumenter
Proportional pressure regulators VEAB

Linear drive units DGO

WIO200A Water in oil sensor

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

Programmable pressure transmitters PTM

Technical Specifications

WI180C-PB. Online-datablad

UNISONIC TECHNOLOGIES CO.,

TDC 4 Indoor voltage transformers

Family of R744 control valves and suggestions for efficient testing

Plug Connectors for Food & Beverage

KNIFE GATE VALVE FAF 6500

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications

VACUUM PRESSURE REGULATOR

WIO200A INSTALLATIONS MANUAL Rev Dato:

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

laser sensors diffuse reflection sensors 2200 analog signal 4 to 20mA / 0 to 10V 5 external teachable measuring ranges

Fundamentals of HVAC Control Systems

Hudevad P200. Technical datasheet

MS-H280-Pro Magnetic Stirrer

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

Modulerende kuglehane

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

Metal Oxide Varistor:TVM-B Series

Slot diffusers. Slot diffusers LD-17, LD-18

Uni-Valve A /S SCOTCH-YOKE. Pneumatisk aktuator - Pneumatic actuator. Type UNI-PD - Type UNI-PS (UNI-PD/PS 50, 70, 85, 100, 125, 150, 200)

Lithium-Ion Jump-Starters / Jumper Cables

Flight Medical Innovations Ltd Product Catalogue. LIT-0139 A Product Catalogue

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting

Navn: DVG V 450EC/F400 varenr.: 95257

Maneurop reciprocating compressors

BRIEF INFORMATION Generation 2 oil level sensors

Low-Drop Voltage Regulator TLE 4276

Varenr.: højre venstre º højre med coating º venstre med coating

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

Engine Powered Forklift ton

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL UNI-EL Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

Switchmode rectifier. Type LEIF with PFC. »We store the world's energy« Network

Navn: DVG V 560EC/F400 varenr.: 95135

Parts List MAJOR Overview. Table of Contents. Topic. This publication contains the following topics:

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

Hudevad P5 Easy Clean

AQ70 Cylinder for water hydraulics

4-POLE MAGNETIC CONTACTORS

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

MJB-A. Posefilter. Egnet til explosivt støv Metode for filterrensning

Diamond Core Drilling

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA

frame bracket Ford & Dodge

MultiProgrammer Manual

MJB-G. Posefilter. Egnet til explosivt støv Metode for filterrensning

Komplet køreklar 6000 W Solcelle anlæg. Kr ,- inkl. moms

OG-3600 Series Fiber Optic Transport for opengear card frame platform w/ SNMP Management

Komplet køreklar 3000 W Solcelle anlæg. Kr ,- inkl. moms

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc.

YDEEVNEDEKLARATION. Nr DA

AQ70 Cylinder for water hydraulics

Unitel EDI MT940 June Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

RPW This app is optimized for: For a full list of compatible phones please visit radiation. result.

Ergonomisk løft. Specials. Højdestabler kasser High stacking boxes. Rulle løfter med 90º tilt Roll handling with 90º tilt

YDEEVNEDEKLARATION. Nr DA

MeasureStar Hjælp til beskyttelse af dit kloaksystem

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

Last Lecture CS Amp. I D V B M 2. I bias. A v. V out. V in. Simplified Schematic. Practical Implementation V GS

Manual Transmission Remove and Install (2,0 DOHC 8V Engine) ( ) Remove

STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

Montageanvisning Assembly instructions. MultiDicer KMD 12, 18

Control cable YSLY-JZ/-JB/-OZ/-OB

Navn: DVG V 450EC/F400 varenr.: 95257

Beovox 5000 versions. Classic Audio Technical Information

LF-8750 GENERATOR Industrial Park Road Van Buren, AR (866)

SOT-363 Plastic-Encapsulate Transistors

High Voltage AC & DC Film Capacitors

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG

SR20 Cylinder for oil hydraulics

Navn: DVG V 355EC/F400 varenr.: 95256

Flow characteristics. 40mm body width 1/4" Ported Flow dm 3 /s Filter 12 Coalescing Filter 2 Regulator 30 Filter Regulator 14 Lubricator 13

BroadLite LED FLOOD LIGHT FIXTURE

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen

ECE 551: Digital System * Design & Synthesis Lecture Set 5

DEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark.

Spare parts list ( ) HD 3.1/31 P

ESI1000I INVERTER GENERATOR

YDEEVNEDEKLARATION. Nr DA. appendiks B 1 - B 4

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS /15 (OSH) 2015 OJ Electronics A/S

SAF Brake Cylinders for disc brakes. Installation and Service Guide

Søjlesvingkraner type SK-C / Pillar swing crane type SK-C

YDEEVNEDEKLARATION. Nr DA

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400

No. Part No. Description Q ty Remarks Cleaner Assembly (Includes Fig.1,2,4 & 5) Cap Tube, inlet Filter, air cleane

YDEEVNEDEKLARATION. Nr DA

Valg af Automationsplatform

3A Step-Down Voltage Regulator

Datamate L-Tek Specification. Pin Numbering DATAMATE L-TEK. Materials. Mechanical. Electrical. Environmental. 5 Female. Female. Male.

Transkript:

Key features Innovative Versatile Reliable Easy to install Silent operation Very low power consumption High precision Integrated piezo technology In-line valves Sub-base valves Simple electrical and pneumatic interfaces Choice of different setpoint specifications Current input Voltage input Integrated pressure sensor with separate output Diagnostics: Operating voltage: over- and undervoltage Setpoint value: falling below and exceeding Consistent pressure regulation performance with long-term stability Mounting the in-line valve via three lateral through-holes H-rail mounting Attaching the in-line valve to the mounting plate Mounting the sub-base valve using the sub-base 2 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Key features In-line valve 1 2 6 3 4 5 1 Power LED (green), fault LED (red) 2 Electrical connection, plug M8 3 Port 2, working air 4 Port 1, compressed air 5 Port 3, exhaust air 6 Through-holes for mounting the valve Sub-base valve 1 3 2 4 6 5 1 Power LED (green), fault LED (red) 2 Electrical connection, plug M8 3 Through-holes for mounting the valve on the sub-base 4 Port 2, working air 5 Port 3, exhaust air 6 Port 1, compressed air 2018/07 Subject to change Internet: www.festo.com/catalogue/... 3

Key features Mounting the valve manifold H-rail mounting The H-rail mounting 1 can be used to mount the manifold rail 2 on H-rails in accordance with EN 60715. 1 2 To do this, the manifold rail with the H-rail mounting attached is mounted on the H-rail 3 and latched in place. 3 Wall mounting Through-holes for wall mounting are located on the manifold rail. 4 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Product range overview Version Valve function Pneumatic Pressure regulation Setpoint value input connection 1, 2, 3 range Voltage type Current type [bar] 0 10 V 4 20 ma Pressure regulator In-line valve 3/3-way valve, normally closed QS 4 0.01 2 0.03 6 0.05 10 Sub-base valve 3/3-way valve, normally closed Flange 0.01 2 0.03 6 0.05 10 2018/07 Subject to change Internet: www.festo.com/catalogue/... 5

Peripherals overview Manifold assembly VEAA 6 7 5 4 3 2 2 1 Accessories Description 1 H-rail NRH-35-2000 For control cabinet installation 18 2 H-rail mounting VAME For assembly of the H-rail 18 3 Manifold rail VABM-P6-15M Connection direction at side, for control cabinet installation 17 4 Manifold rail VABM-P6-15MB Connection direction underneath, for wall mounting and control cabinet installation 17 5 Cover plate VABB 17 6 Proportional pressure regulator VEAA 17 7 Connecting cable NEBU 18 Page/Internet 6 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Type codes VEAA 3 1 R1 Type code VEAA Proportional pressure regulator Valve type L B In-line valve Sub-base valve Valve function 3 3/3-way valve, normally closed Pressure range D2 D9 D11 0 2 bar 0 6 bar 0 10 bar Pneumatic connection F Q4 Flange/sub-base Push-in connector 4 mm Setpoint input V1 A4 Voltage variant 0 10 V Current variant 4 20 ma Operating voltage 1 24 V DC Electrical connection R1 Plug M8, 4 pin 2018/07 Subject to change Internet: www.festo.com/catalogue/... 7

Technical data -M- Flow rate 7 13 l/min -P- Voltage 24 V DC -L- Pressure regulation range 0.01 2 bar 0.03 6 bar 0.05 10 bar General technical data Type code VEAA-L VEAA-B Valve type In-line valve Sub-base valve Valve function 3-way proportional pressure regulator Dimensions W x L x H [mm] 15 x 54.5 x 85 15 x 61 x 66 Standard nominal flow rate Page 10 Pneumatic connection 1, 2, 3 QS-4 Flange Sealing principle Soft Actuation type Electrical with piezo element Display type LED Type of control Directly controlled Type of reset Mechanical spring Type of mounting Via through-hole, via accessories Mounting position Any Product weight [g] 55 Electrical data Electrical connection Plug M8x1, 4-pin, to EN 60947-5-2 Nominal operating voltage [V DC] 24 Operating voltage range [V DC] 19 29 Residual ripple [%] 10 Max. electrical power consumption [W] 1 Setpoint input signal Voltage [V DC] 0 10 Current [ma] 4 20 Accuracy of analogue output [%] 2 Short circuit protection For all electrical connections Reverse polarity protection For all electrical connections Degree of protection IP65 -H- Note Safety position, VEAA: If the electrical power supply fails, the outlet pressure is maintained unregulated and may rise or fall valve blocked. 8 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Technical data Operating and environmental conditions Operating medium Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases Note on operating/pilot medium Lubricated operation not possible Inlet pressure at port 1 1) [bar] 0 11 FS (full scale) hysteresis [%] 0.25 FS (full scale) linearity error [%] ± 0.5 FS (full scale) repetition accuracy [%] ± 0.4 FS (full scale) absolute accuracy [%] Max. 0.7 Temperature coefficient [%/K] 0.05 Ambient temperature [ C] 0 50 Temperature of medium [ C] 5 50 Storage temperature [ C] 20 70 Corrosion resistance class CRC 2) 2 CE marking (see declaration of conformity) To EU EMC Directive Certification RCM compliance mark * 1) Inlet pressure 1 should always be 1 bar higher than the maximum regulated outlet pressure. 2) Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications. Materials Seals Housing Note on materials NBR PA-reinforced RoHS-compliant Pin allocation, electrical connection Pin Function 1 +24 V DC supply voltage 2 + Setpoint value 3 GND 4 + Actual value Function An integrated pressure sensor records the pressure at the working port and compares this value with the setpoint value. The pressure is automatically readjusted in the event of deviations. 2018/07 Subject to change Internet: www.festo.com/catalogue/... 9

Technical data VEAA- -D2-, pressure regulation range 0.01 2 Flow rate qn from 12 as a function of outlet pressure p2 Flow rate qn from 23 as a function of outlet pressure p2 10 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Technical data VEAA- -D9-, pressure regulation range 0.03 6 Flow rate qn from 12 as a function of outlet pressure p2 Flow rate qn from 23 as a function of outlet pressure p2 2018/07 Subject to change Internet: www.festo.com/catalogue/... 11

Technical data VEAA- -D11-, pressure regulation range 0.05 10 Flow rate qn from 12 as a function of outlet pressure p2 Flow rate qn from 23 as a function of outlet pressure p2 12 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Technical data Dimensions In-line valve Download CAD data www.festo.com 1 Plug M8x1, 4-pin Type code B1 B2 D1 D2 H1 H2 H3 H4 H5 H6 H7 VEAA-L 15 9 4 3.2 85 76 14 19 9.5 9.6 4.8 Type code L1 L2 L3 L4 L5 VEAA-L 58 54.5 46.5 16.6 14.2 2018/07 Subject to change Internet: www.festo.com/catalogue/... 13

Technical data Dimensions Sub-base valve Download CAD data www.festo.com 1 Port 1, compressed air 2 Port 2, working air 3 Port 3, exhaust air 4 Plug M8x1, 4-pin Type code B1 B3 D3 H1 H2 H8 VEAA-B 15 3.6 3.2 66 58 6 Type code L1 L2 L3 L6 L7 L8 L9 L10 VEAA-B 61 54.5 46.5 57.3 3.6 30.7 21.4 9.5 14 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Technical data Dimensions Download CAD data www.festo.com Connection direction at side Type code B1 B2 B3 D1 D2 D5 D6 D7 D8 D9 H1 H2 H3 H4 H5 H9 VABM-P6-15M-G18-M5-4 15 7.5 8.5 G1/8 6 4.5 M3 M5 2.9 M4 61.5 50 34 53.9 3.8 19.5 VABM-P6-15M-G18-M5-6 VABM-P6-15M-G18-M5-8 Type code L1 L2 L3 L4 L5 L6 L7 L8 L10 L11 T1 T2 T4 T5 T6 VABM-P6-15M-G18-M5-4 63 45 30 16.5 9 15 9 15 49 7 9 6 7 5 7 VABM-P6-15M-G18-M5-6 93 75 60 79 VABM-P6-15M-G18-M5-8 123 105 90 130 2018/07 Subject to change Internet: www.festo.com/catalogue/... 15

Technical data Dimensions Download CAD data www.festo.com Connection direction underneath Type code B1 B2 B3 D1 D2 D3 D4 D5 D6 D7 H1 H2 H3 H4 H5 H6 VABM-P6-15MB-G18-M5-4 15 7.5 8.5 G1/8 6 G1/8 M5 4.5 M3 2.9 61.5 50 34 53.9 3.8 50.5 VABM-P6-15MB-G18-M5-6 VABM-P6-15MB-G18-M5-8 Type code H7 H8 L1 L2 L3 L4 L5 L6 L7 L8 L9 T1 T2 T3 VABM-P6-15MB-G18-M5-4 34 15 63 45 30 16.5 9 15 9 15 31.5 9 6 5 VABM-P6-15MB-G18-M5-6 93 75 60 VABM-P6-15MB-G18-M5-8 123 105 90 16 Internet: www.festo.com/catalogue/... Subject to change 2018/07

Accessories Ordering data In-line valve Pressure regulation range Part No. Type code [bar] Voltage type, 0 10 V 0.05 10 8046905 VEAA-L-3-D11-Q4-V1-1R1 0.01 2 8046901 VEAA-L-3-D2-Q4-V1-1R1 0.03 6 8046903 VEAA-L-3-D9-Q4-V1-1R1 Current type, 4 20 ma 0.05 10 8046906 VEAA-L-3-D11-Q4-A4-1R1 0.01 2 8046902 VEAA-L-3-D2-Q4-A4-1R1 0.03 6 8046904 VEAA-L-3-D9-Q4-A4-1R1 Sub-base valve Voltage type, 0 10 V 0.05 10 8046896 VEAA-B-3-D11-F-V1-1R1 0.01 2 8046892 VEAA-B-3-D2-F-V1-1R1 0.03 6 8046894 VEAA-B-3-D9-F-V1-1R1 Current type, 4 20 ma 0.05 10 8046897 VEAA-B-3-D11-F-A4-1R1 0.01 2 8046893 VEAA-B-3-D2-F-A4-1R1 0.03 6 8046895 VEAA-B-3-D9-F-A4-1R1 Manifold rail Connection direction at side 4 valve positions 8083543 VABM-P6-15M-G18-M5-4 6 valve positions 8083545 VABM-P6-15M-G18-M5-6 8 valve positions 8083547 VABM-P6-15M-G18-M5-8 Connection direction underneath 4 valve positions 8083544 VABM-P6-15MB-G18-M5-4 6 valve positions 8083546 VABM-P6-15MB-G18-M5-6 8 valve positions 8083548 VABM-P6-15MB-G18-M5-8 Cover plate Including screws (2) and O-rings (3, preassembled) 4054657 VABB-P6-M 2018/07 Subject to change Internet: www.festo.com/catalogue/... 17

Accessories Ordering data Description Part No. Type code Connecting cable Straight socket, M8x1, 4-pin Open end, 4-wire Angled socket, M8x1, 4-pin Open end, 4-wire Straight socket, M8x1, 4-pin Straight plug, M8x1, 4-pin Technical data Internet: nebu 2.5 m 541342 NEBU-M8G4-K-2.5-LE4 5 m 541343 NEBU-M8G4-K-5-LE4 2.5 m 541344 NEBU-M8W4-K-2.5-LE4 5 m 541345 NEBU-M8W4-K-5-LE4 2.5 m 554035 NEBU-M8G4-K-2.5-M8G4 H-rail To EN 60715, 35 x 7.5 (WxH), for control cabinet installation 35430 NRH-35-2000 H-rail mounting For H-rail NRH-35-2000 4054652 VAME-P7-T Mounting plate For in-line valve 4054655 VAME-P6-Y 18 Internet: www.festo.com/catalogue/... Subject to change 2018/07