ELENA Mikrobiologisk sikker sænkning af varmt vandstemperaturen Presentation Name Danish Clean Water
Præsentation ved ( DCW) Lars Bendixen Telefon 6013 9017 Lars@dansihcleanwater.dk www.danishcleanwater.dk Nørrekobbel 11 6400 Sønderborg ELENA 27/9 2016 Odense 2
History of DCW starts @ Danfoss The company was founded in April of 2008 to exploit the technology of on site production of disinfectants. The funding came from PMCStar private venture capital owned by Peter Mads Clausen one of the largest Danfoss shareholders. Still Peter Mads Clausen is a major shareholder. The company was at beginning granted Trusted by Danfoss status which allows it s access to all the Danfoss facilities including laboratories, patent office and engineering workshops. Prototype generators were produced and installed at several locations at end of 2008 and are still running. The technology was launched commercially in mid 2009 and installations have been sold in more than twenty countries with > 450 units in operation. ELENA 27/9 2016 Odense 3
Tidslinie Aurora House -Glasgow 2009 2009 2010 2011 2012 2013 2014 2015 2016 2016 North Tee Hospital -UK Today jan 1 - nov 30 ca. 37 referencer nov 1 - nov 30 Projekt forløb ELENA 27/9 2016 Odense 4
Reference eksempler i Danmark Favrskov skole Hospital in Sønderborg Hospital in Aabenraa Lejligheder/ udlejning Lewisham Hospital Richters Plejecenter Fælleskøkken Klosterparken Mølledams plejecenter Humlehøj hallen Aarhus Randers Horsens Hospital Flensburg Køge sygehus Vordingborg Psy. Hospital Annebergcentret, Aalborg Lollandshus, Aalborg Teglgårdsminde, Skørping ELENA 27/9 2016 Odense 5
EUDP Projekt Energiteknologisk udvikling og demonstration Projekt Energistyrelsens Udviklings og Demonstrationsprojekt Mikrobiologisk sikker sænkning af varmtvandstemperaturen Projekt tilsagn 5,2 mio. Demonstration af teknologien Udvikling af den optimale doseringsstrategi af biocidet Neuthox Udvikling af optimeret DCW enhed til markedet Afdækning af alle problematikker ved dosering i varmt vandsystemer Projekt deltager ELENA 27/9 2016 Odense
Projekt deltager DCW projekt ejer og leder Statens Serum Institut v. Søren Uldum Legionella Serotypning Godkendelse af temperatursænkning Teknologisk Institut Kvantitative Legionella tests Sønderborg Fjernvarme Varmetabsberegninger Varmeforbrugsdokumentation Efter endt projektforløb udfører Dansk Energi Rådgivning varmetabsberegninger. ELENA 27/9 2016 Odense
Hvad er et biocid Ordet biocider er ikke særligt kendt, men de fleste forbrugere har alligevel haft brug for et biocidprodukt på et eller andet tidspunkt - for eksempel i form af myggebalsam, insektspray eller musegift i sommerhuset. Biocider er en betegnelse for kemiske stoffer, der er beregnet til at bekæmpe skadedyr, bakterier og svampe med mere. Biocider bruges i modsætning til plantebeskyttelsesmidlerne ikke på landbrugets marker og i gartnerier, men til gengæld til bekæmpelse i en lang række andre sammenhænge. Biocidprodukter skal godkendes, før de må sælges. For at et middel kan blive godkendt, skal tre vigtige forhold være i orden: 1. Det må ikke være skadeligt for de mennesker, der skal bruge det 2. Det må ikke være skadeligt for miljøet 3. Det skal være effektivt til den konkrete anvendelse ELENA 27/9 2016 Odense 8
Compliance med ECHA Alle biocider er underlagt Eu s biocidforordning In-situ systemer skal være listet siden 1 September 2015 HOVEDGRUPPE 1: DESINFEKTIONSMIDLER Produkttype 5: Drikkevand Produkter til desinficering af drikkevand til både mennesker og dyr. ELENA 27/9 2016 Odense 9
Det ideelle biocid Fremragende effekt mod mikrober Lav koncentration Let at håndterer Simpel at måle Lav sikkerheds klasse Kost effektiv i anskaffelse og brug Stort udvalg af myndighedsgodkendelser Kan anvendes i mange forskellige installationer God miljøprofil Simpel at dosere Derfor blev desinfektionsmidlet Neuthox valgt tilbage i 2008 ELENA 27/9 2016 Odense 10
Circular membrane cell Hvad er Neuthox? Water to be disinfected Tap water connection Water Softener Salt container Neuthox injection Dosing pump Neuthox container I Neuthox er der 2 substanser Hypochlorsyre Hypochlorit Måles i FAC Frit klor 500 ppm opløsning, ph 8,3 1 liter er nok til at desinficere 1-2 m3 vand Sker ved en elektrolytisk proces ELENA 27/9 2016 Odense 11
Drift af anlæg ved <50 C fremløbstemperatur Baggrund. Varmt vands temperatur skal være 50 C eller højere jævnfør BR15 med mindre der indføres en alternativ løsning til sikring mod Legionella. DCW sikrer mod Legionella hvilket er dokumenteret i et omfattende testprogram dokumenteret via projekt EUDP 2013-I. Konsekvens. Udnytter kunderne mulighed for at sænke temperaturen i det varme vand til under 50 C er der ikke mere en beskyttelse mod Legionella fra det varme vand. Med et DCW system er det sikkert at temperatur sænke, det er fuldt dokumenteret i EUDP rapporten udarbejdet i samarbejde med Statens Serum Institut For at kunne leve op til kravene her skal varmt vands systemet være udformet så dosering sker jævnfør DCW s anvisninger. ELENA 27/9 2016 Odense 12
Legionella Alle former for varmtvandssystemer giver optimale betingelser for Legionella vækst Selv i anlæg med meget høj temperatur i cirkulations systemet vil der være døde zoner, hvor temperaturen er så lav at der vil forekomme Legionella vækst. Desinfektion af varmt vandsystemer henvender sig til hospitaler, skoler, hoteller, plejehjem, sportsfaciliteter og lign. Store cirkulations systemer Installationer med udsatte beboer (reduceret immunforsvar) ELENA 27/9 2016 Odense 13
Legionella Risikoen for at blive smittet med den farlige vandbakterie Legionella under morgenbruseren er langt større end hidtil antaget. En EU-undersøgelse afslører, at hver tiende vand-installation i Danmark har været årsag til den alvorlige lungebetændelse Legionærsyge, som kommer af Legionella bakterien. Høj feber, lungebetændelse og i værste tilfælde dødsfald er udsigterne, hvis man er så uheldig at pådrage sig Legionærsygen. Reference: http://www.sundhedsguiden.dk/da/temaer/alle-temaer/almene-infektioner-og-parasitsygdomme/infektionssygdomme/legionaersyge/ ELENA 27/9 2016 Odense 14
6 Installationer 1. Alsion - Kontor og universitet 2. Sønderborg Sygehus 3. Hotel Comwell Sønderborg 4. Humlehøj, sportsfaciliteter 5. Mølledams plejecenter 6. Sønderborg Andelsboligforening Etageejendom i Stenbjergparken Variation i installationer iht. alder, forbrug og størrelse var en af udvælgelses parametrene. Der blev foretaget 600 Legionella test ELENA 27/9 2016 Odense 15
Legionella i varmtvandssystemer I DK må vi behandle varmt vand, ikke koldt vand Før projekt start Der var Legionella i alle system på nær én I mange tilfælde var Legionella forekomst på et for højt niveau Der var Legionella forekomster i hoved linje samt ved tappesteder Der var Legionella i cirkulations ledninger hvor der anvendes 70 graders desinfektion. ELENA 27/9 2016 Odense 16
Nationale grænseværdier Denmark: 0-999 OK Follow but no further action. UK: 0-99 OK In few samples or more = OK Too high - action needed In most samples => disinfection High risk immediately take action Disinfection and consider system upgrade ELENA 27/9 2016 Odense 17
Tønder fælleskøkken. Sensor monteret i ind sløjfning Anlæg placeret i teknikrum Kører fuldautomatisk Installeret November 2015 Der blev foretaget chok dosering over en weekend Kraftig Legionella udbrud ELENA 27/9 2016 Odense 18
Tønder fælleskøkken. Sorte lag er biofilm hvori bakterie lever Findes i alle slags vandrør Gennem skylning ved 50 ppm i 1 timer eller 25 ppm i 2 timer sikrer effektiv undskyldning ELENA 27/9 2016 Odense
Test resultater fra Mølleparkens plejecenter inden projekt start Test og målinger udført inden forsøgs start Cirkulations temperatur = 65 Tappesteder anvendt på daglig basis Legionella målt til 150.000 CFU/Liter Meget højt niveau Legionella blev påvist i cirkulations ledning og på tappesteder ELENA 27/9 2016 Odense 20
DCW unit på Mølleparkens plejecenter DCW Unit ORP Kontroller Doserings pumpe Salt beholder 36 værelser tilsluttet ud af 56 mulige Legionella reduceret til < 4 CFU/L Varmtvandstemperatur sænkning fra 60 til 45 grader 27.000,- DKK i varmetabsbesparelse Neuthox tank ELENA 27/9 2016 Odense 21
Mølleparkens plejecenter Bruser A 16.01.14 04.02.14 11.03.14 28.10.14 30.03.15 10.06.15 29.09.15 05.11.15 qpcr spp. 1335 3678 13785 5600 ND ND ND ND qpcr pneu. 5826 3953 5126 700 ND ND ND 992 Dyrkning 50000 38 49000 ND ND 2000 ND Shower; A-sample 100000 10000 1000 100 10 1 16.01.14 04.02.14 11.03.14 28.10.14 30.03.15 10.06.15 29.09.15 05.11.15 Dyrkning qpcr pneu. qpcr spp. qpcr spp. qpcr pneu. Dyrkning Yellow line = baseline end, Pink line = concentration increased, Blue line = circulations temperature reduced, Green line = concentration reduced ELENA 27/9 2016 Odense 22
Mølleparkens plejecenter Cirkulation, sys 16.01.14 04.02.14 11.03.14 30.09.14 10.12.14 25.02.15 30.03.15 10.06.15 29.09.15 05.11.15 qpcr spp. 11114 2140 380 ND ND ND ND ND ND ND qpcr pneu. 25380 2040 877 ND ND ND ND ND ND ND Dyrkning 40000 113 ND ND ND ND ND ND ND Circulation 100000 10000 1000 100 10 1 16.01.14 04.02.14 11.03.14 30.09.14 Dyrkning 10.12.14 25.02.15 30.03.15 10.06.15 29.09.15 05.11.15 qpcr pneu. qpcr spp. qpcr spp. qpcr pneu. Dyrkning Yellow line = baseline end, Pink line = concentration increased, Blue line = circulations temperature reduced, Green line = concentration reduced ELENA 27/9 2016 Odense 23
TCO og Driftsomkostninger Beregnings eksempel ud fra hospital med et varmvandsforbrug på 25m3 pr. dag. TZero Vejledende Installationspris kr. 100.000,- Forventet service omkostninger per år kr. 4.000,- Driftsomkostninger Totalforbrug 20 liter Neuthox / Døgn Driftsomkostninger per døgn = 7,5 kr. Driftsomkostninger per år = 2.700,- kr. Service og drift i alt 6.700,- kr. Omkostning om året i en 5 års periode 26.700,- kr ELENA 27/9 2016 Odense 24
Doserer kun ved behov Stop af dosering hvis intet vandforbrug Weekend stop er ikke noget problem Aktuelt tilfælde viser forløb over en måned med 4 stop hver Søndag Starter mandag morgen igen ELENA 27/9 2016 Odense 25
Installation princip Dosering i varmtvandssystemer ORP sensor måler og sikrer det rette Neuthox niveau i vandet. Måler vand forbrug og mængden af Neuthox Installationsprincipper skal følges efter vor anvisning Lokal smed kan stå for montage og installering af anlæg. DCW partner skal stå for idriftsætning og servicering ELENA 27/9 2016 Odense 26
Regelsæt er udarbejdet for at sikre bakterie frit vand 1. Opstartsfase 2. Driftsfase uden temperatursænkning 3. Temperatursænkning beslutning om start for sænkning 4. Temperatursænkning drift ELENA 27/9 2016 Odense 27
Beregning af energibesparelse og tilskud 1. Der foretages flow og temperatur målinger 2. Dokumentation fremsendes til DER 3. Beregner og vurderer, I fremtiden vil det kunne gøres online. 4. 2.000 3.000 kr. per anlæg i sagsomkostninger. 5. Tilskud svarer til ca. 15% af anlægs investering 6. Tilskud afregnes direkte mellem forbruger og energiselskab ELENA 27/9 2016 Odense 28
Udviklet produkt for projektet Fuldautomatisk anlæg Indbygget doserings pumpe 33 liter brine og Neuthox tank Automatisk dosering efter behov Alarm signal Mulighed for opkobling til SRO anlæg H x B x D = 70 x 50 x 26 ( cm ) Inkluderet i levering Enhed Tzero model T05-09 Dokumentation ORP sensor og transmitter Injektor for Neuthox 10 Kg NaCl ( salt ) Forbindelses slanger og strømstik. Installations vejledning ELENA 27/9 2016 Odense 29
Det med småt! Anlæg er altid på lager Forsendelse kan ske 1-2 dage efter ordre modtagelse DCW har faste partner der kender til idriftsætning, servicering og vedligehold Service kontrakt skal laves med partner for at der kan opnås energibesparelse. ELENA 27/9 2016 Odense 30
Sub konklusion Cirkulationsledning er fri for Legionella, der er mulighed for energibesparelse Bruser og vandhaner er fri for Legionella når der er regelmæssig forbrug Stop for dosering er ikke noget problem Varmetab kan reduceres op til 15-20%. ELENA 27/9 2016 Odense 31
Konklusion ELENA 27/9 2016 Odense 32