Smart Motor Manager. Bulletin 825. User Manual

Størrelse: px
Starte visningen fra side:

Download "Smart Motor Manager. Bulletin 825. User Manual"

Transkript

1 Smart Motor Manager Bulletin 825 User Manual

2 Important User Information

3 ATTENTION IMPORTANT European Communities (EC) Directive Compliance EMC Directive

4 Low Voltage Directive ATTENTION

5 Table of Contents Chapter 1 Introduction Chapter 2 Equipment Description Chapter 3 Functions

6 ii Table of Contents

7 Table of Contents iii Ω Chapter 4 Assembly and Installation Chapter 5 Setting the Operational Parameters Chapter 6 Commissioning and Operation

8 iv Table of Contents Chapter 7 Testing and Maintenance Chapter 8 Error Diagnosis and Troubleshooting Chapter 9 Applications/Wiring

9 Table of Contents v, Chapter 10 References Figures

10 vi Table of Contents,

11 Table of Contents vii

12 viii Table of Contents Tables

13 Table of Contents ix

14 x Table of Contents Notes:

15 Chapter 1 Introduction Why Have an Electronic Control and Protection System? Figure 1.1 Bulletin 825 Smart Motor Manager

16 1-2 Introduction Operational Demands of the Motor/Drive Temperature Rise Motor Operating Characteristics

17 Introduction 1-3 Figure 1.2 Operating Characteristics of an AC Motor Pv Pve I Ie, n ne, cos ϕ, η, η n cos ϕ I Pv Ie ns P Power Pe Rated operational power Pv Power losses Pve Power losses under rated conditions, Operational current, e Rated service current n Speed n e Rated operational speed n s Synchronous speed cos ϕ Power factor η Efficiency P [%] Pe Operating characteristics of an AC motor as a function of load. Between no load and half load, the losses increase only slightly with rising load. Between half load and rated load, the change in efficiency is minimal, and the power factor approaches its maximum. The losses increase approximately proportional to the load. Above rated load, the losses increase more rapidly than the load. Current and Temperature Curves

18 1-4 Introduction Figure 1.3 AC Current Profile of a Motor Starting Direct-on-Line, A Starting current t A Starting time, e Rated service current t Time IA 2 2 IA I 2 2 Ie t A Oscillogram of switching on a squirrel-cage induction motor by direct-on-line starting. The high motor starting current, A flows during the starting time (t A ). If this is less than the limit specified by the manufacturer (usually 10 s), the starting current does not cause an excessive temperature rise. The brief, asymmetrical peak when switching on can be ignored. Figure 1.4 Temperature Rise Characteristics of Motor Windings ϑ ϑ G ϑ s ϑ K 0 t A t B ϑe t ϑ G ϑ K ϑ s ϑ e t A t B Temperature limit of the insulation Coolant temperature Temperature rise at start Temperature rise when operated continuously at rated current Starting time Permitted stalling time Temperature rise in a motor winding. During the starting time (t A ), the temperature of the winding rises very rapidly; at the end of startup, the temperature drops temporarily because heat is transferred to the laminated core. Limiting Temperatures, Insulation Classes

19 Introduction 1-5 Insulation Aging Figure 1.5 Reduction in Average Life (E M ) of a Motor when Winding is Continuously Overheated % 100 E M E M ϑ G Average motor life Temperature limit of the insulation K +10K +15K +20K ϑ G Rotor Temperature Operational Requirements for Installation

20 1-6 Introduction Personnel and Installation Safety Bulletin 825 Smart Motor Manager as an Automation Component

21 Chapter 2 Equipment Description System Structure System Components Installation

22 2-2 Equipment Description Modular Design Figure 2.1 Modular Design of the Bulletin 825 Smart Motor Manager Basic unit, Cat. No. 825-M Option: Cat. No. 825-MLV Cat. No. 825-MMV PT100 Communication Communication Network Cat. No. 825-MST Thermal utilization module Core Balance Current Transformer ma Converter module ➊ ➊ ➊ Available from Prosoft Technology, Inc. (not an Allen-Bradley product). References to third-part products are provided for informational purposes only. Prosoft Technology, Inc., is solely responsible for the accuracy of information, supply, and support of this product. For further information regarding this particular referenced product, please contact Prosoft Technology, Inc., in the U.S. at (661) or your local Prosoft Technology, Inc. distributor.

23 Equipment Description 2-3 Block Diagram Figure 2.2 Block Diagram ϑ amb L1 L2 L MCM M 3 ~ A1 (-) A2 (+) Y11 Y12 Y13 Y21 Y22 k, l T1, T2 L1 L2 L3 F L1 L2 L3 1T1/1T2/1T3 6T1/6T2/6T3 7T1/7T2/7T3 Supply Operation LCD Emergency start Disable settings Controller 825-M Remote reset Basic unit 825-M Earth fault 825-MST Thermistor overload 4 20 ma Phase sequence 825-MLV Phase failure PT100 #1 #6 (RTD) PT100 #7 (RTD) 825-MMV Stator / bearing temperature Ambient temperature Communication Interface Warning/Trip 95/96 97/98 Main relay MR 13/14 Alarm relay AL 23/24 Auxiliary relay #1 33/34 Auxiliary relay #2 43/44 Auxiliary relay #3 I+ / I- Analog output 53/54 Auxiliary relay #4 63/64 Auxiliary relay #5 Choice 825-MLV or 825-MMV PC PLC Network 24 V AC/DC 24 V AC/DC Y31 Y32 Y41 Y #1 #2 Control inputs 825-MDN 3600-RIO 3600-MBS 825-MPB

24 2-4 Equipment Description Operating Elements Figure 2.3 Front View with Operating Elements ➊ ➋ ➏ ➊ ➋ ➌ ➍ ➎ ➏ ➐ Fault indicator (LED) Flashing: warning Steady state: trip LCD: Single line (two lines of text are displayed alternately) Values: Selection of mode Actual: Indication of actual operational data Set: Setting mode (set/modify, store parameters) Recorded: Indication of statistical data Select: Select function and enter/change operating parameter Settings: Enable entry (Change) and memorize (Enter) Test: Verifies operation of Smart Motor Manager. Reset: Enables the Smart Motor Manager after a trip. ➌ ➍ ➎ ➐

25 Equipment Description 2-5 Specifications Basic Unit and Converter Module Table 2.A Environmental Ratings Temperature Operation Storage Transport Damp heat IEC Climatic cycling IEC M, enclosed in panel Terminals as per IEC as per IEC C ( F) C ( F) C ( F) Climatic Withstand 40 C (104 F), 92% relative humidity, 56 days 25/40 C (77/104 F), 21 cycles Enclosure Protection Class IP65 IP20 Resistance to Vibration Hz, 3 G Resistance to Shock 30 G, shock duration 18 ms, half a sine wave in x, y, z directions

26 2-6 Equipment Description Table 2.B Nominal Rated Voltages U e Primary Detection Circuit Table 2.C Electrical Ratings 825- MCM MCM MCM180 MCM630 MCM630N Motor Circuit as per IEC, SEV, VDE V AC 660V AC 1 000V AC as per CSA, UL 240V AC 600V AC 600V AC Control Circuit Main relay (MR) 95 98, supply A1, A2 Phase sequence protection L1, L2, L3 as per IEC V AC as per SEV 380V AC as per UL, CSA 240V AC Alarm relay (AL) 13/14 Auxiliary relay #1, #4, #5 as per IEC V AC as per SEV 250V AC as per UL, CSA 240V AC Auxiliary relays #2, #3 50V AC/30V AC Control inputs #1, #2 24V AC/DC Test Voltage 825- MCM2 Motor Circuit 825- MCM MCM180 MCM MCM630N U as per IEC imp 2.5 kv Control Circuit Between control circuits and to all other circuits ➊ Main relay (MR) 95 98, supply A1, A2 Phase sequence protection L1, L2, L3 Alarm relay (AL), auxiliary relay #1, #4, #5 as per IEC Core balance current transformer k, I Control inputs #1, #2 Auxiliary relays #2, #3 as per IEC U imp 6 kv U imp 4 kv U imp 2.5 kv U imp 8 kv U imp 12 kv ➊ The measuring inputs for PT100 and PTC, the 4 20 ma output, and the communication interface are not isolated from one another.

27 Equipment Description 2-7 Standards Table 2.D Supply Ratings Nominal supply voltage U s Permissible voltage fluctuation Power consumption Short-circuit protection 50/60 Hz, 22 24, 33 36, 44 48, , , , 440V AC 24 48, , 220V DC AC U S DC U S for 24 48V DC DC U S for V DC DC U S for 220V DC AC 13 VA, DC 10 W max. With the appropriate supply cable rating, the supply module is short-circuit proof.

28 2-8 Equipment Description Table 2.E Relay Ratings Contact Data of Output Relays Main Relay (MR) Contacts fitted 1 N/C and 1 N/O contact, galvanically separated Nominal operating voltage as per UL, CSA: pilot duty 240 V [V] Continuous thermal current [A] 4 Rated operating current for AC-15 [A] Max. permissible switching current (cos ϕ = 0.3) AC-15 [A] Rated operating current for DC-13 without prot. network, L/R = 300 ms [A] Max. rated current of back-up fuse: [A] 10 A, 500V AC, Type gg Alarm Relay (AL), Auxiliary Relays #1, #4, #5 Contacts fitted 1 N/O contact each Continuous thermal current 4 A Max. permissible switching voltage 400V AC, 125 VDC Nominal Operating Current cos ϕ = 1 4 A at 250V AC or 30V DC cos ϕ = 0.4, L/R = 7 ms 2 A at 250 VAC or 30V DC Max. Switching Power cos ϕ = VA, 150 W cos ϕ = 0.4, L/R = 7 ms 500 VA, 60 W as per UL/CSA 240 V, 1 A pilot duty Auxiliary Relays #2, #3 Contacts fitted 1 N/O contact each Continuous thermal current 4 A Max. permissible switching voltage 48 VAC, 30 VDC Max. Switching Power cos ϕ = W cos ϕ = 0.4, L/R = 7 ms 60 W

29 Equipment Description 2-9 Table 2.F Terminals Range of gauges: Cat. No. 825-M plug-in terminals m 2, single wire (AWG No ) m 2 double wire (AWG No ) as per UL AWG No as per VDE nominal gauge 1.5 mm 2 Main circuit 825-MCM2/ 825-MCM MCM MCM630(N) Terminals: 2 x 2.5 mm 2 /1 x 4 mm 2 (2 x in 2 /1 x in 2 ) 2 x AWG No /1 x AWG No Aperture or busbars: Wire 19 mm max. 20/16 x 4 mm Bus bars: 25 x 8 mm

30 2-10 Equipment Description Main Current Transformers for the Motor Circuit Table 2.G Main Current Transformer Ratings Minimum nominal operating voltage Nominal operating voltage of motor Minimum rated primary current, 1n Nominal operating current of motor Rated secondary current 1 A or 5 A Class and nominal overcurrent factor 5 P 10 ext. 120% ➊ Power rating According to power consumption in leads and measuring circuits Rated frequency 50/60 Hz Burden: 825-M MCM2 825-M MCM20 Power consumption at max. rated current ➋ 0.1 VA/phase 0.4 VA/phase Continuous thermal current 3 A 24 A Thermal current, 1 s duration 250 A 600A Frequency of input current 50/60 Hz 50/60 Hz General Notes on 825-MCM No-load An open-circuit secondary is permitted, as the burden is installed in the detection module ➊ Designation according to IEC part 2: ➋ 5 Total measurement error (percentage): ±5% within range up to rated nominal overcurrent (10X) ±1% at rated nominal primary current P For protection purposes 10 Rated nominal overcurrent factor: 10X rated nominal primary current ext. 120% Extended rated thermal current: 120% of rated nominal primary current (if, e motor > 87% of rated nominal transformer current) With starting current 10, e : class 5 P 20 The current transformer error in addition to the basic unit error 2.5 A with Cat. No. 825-MCM2, 20 A with Cat. No. 825-MCM20

31 Equipment Description 2-11 Core Balance Current Transformer Table 2.H Recommended Data for Core Balance Current Transformer minimum detectable earth (ground) fault Nominal ratio K n = Pickup current of basic unit earth (ground) fault protection Burden: Measuring circuit 825-M Power consumption at max. rated current Continuous thermal current Thermal current, 1 s duration Frequency of input current 0.4 VA 0.5 A 25 A 50/60 Hz Short-Circuit Protection Choosing a Circuit Breaker or Fuse and Associated Contactor The Short-Circuit Coordination of the Starter Must Always be Taken into Account

32 2-12 Equipment Description Response Supply Voltage Failure Failure of Supply Voltage > 30 ms Recovery of the Supply Voltage

33 Equipment Description 2-13 Automatic Recognition of Converter Module Table 2.I Converter Module Related Error Messages Verify Sequence Display After switching on supply Supervision while motor is stationary When running, as soon as the link is interrupted the basic unit will trip and Link between basic unit and display one or more of the following converter module causes: 825-MCM NOT CON short circuit, thermal, earth fault (Holmgreen = residual), asymmetry, overcurrent Verification that FLC on basic unit is within range of converter module Supervisory circuits After switching on supply After each change in setting of rated current Continuous monitoring (hardware errors, supply, etc.) Ie OUT OF RANGE ERROR 825-MCM

34 Chapter 3 Functions Menu Overview Actual Values Table 3.A Actual Values Overview Display List Option Card Cat. No. Page Display List Option Card Cat. No. I MOTOR A 6-6 I earth - H %I 6-7 I MOTOR %, e 6-5 I earth - C ma 6-7 I 1 %, e 6-6 Tambient ºC 825-MMV 6-7 I 2 %, e 6-6 PT100 #1( 6) ºC 825-MMV 6-7 I 3 %, e 6-6 PROBUS 825-MPB 6-7 Page TRIP IN s 6-6 RIO 3600-RIO 6-7 RESET IN s 6-7 MODBUS 3600-MBS 6-7 ASYM % 6-7 DevNet 825-MDN 6-7

35 Functions 3-2 Set Values Table 3.B Set Values Overview Parameter List Option Card Cat. No. Page Parameter List Option Card Cat. No. Page THERMAL TRIP 5-4 THERMAL RESET LEVEL 5-10 THERMAL WARNING 5-4 COOLING CONSTANT RATIO 5-10 ASYMMETRY TRIP 5-5 PTC TRIP 825-MST 5-10 ASYMMETRY WARNING 5-5 PTC RESET 825-MST 5-10 OVERCURRENT TRIP 5-5 CONTROL INPUT # OVERCURRENT WARNING 5-5 DELAY AUX REL # EARTH FAULT PROTECTION 5-6 SPEED SWITCH 825-MST 5-11 EARTH FAULT HOLMGREEN TRIP 5-6 DISABLE FUNCTION 5-11 EARTH FAULT CORE TRIP 825-MST 5-7 CONTROL INPUT # EARTH FAULT CORE WARNING 825-MST 5-7 DELAY AUX REL #3 825-MST 5-12 SHORT CIRCUIT PROTECTION 825-MST 5-7 NEW FULL LOAD CURRENT 5-12 UNDERLOAD TRIP 5-8 PHASE REVERSAL TRIP MLV UNDERLOAD WARNING 5-8 PHASE LOSS TRIP 5-13 STAR DELTA STARTING 825-MLV 5-8 PT100 PROTECTION WARM STARTING 5-9 PT100 RESET/WARNING 825-MMV 5-13 START INHIBIT 5-11 OUTPUT 4 20 ma 825-MST 5-15 START CONTROL 5-9 STATION NUMBER 5-16 MAIN RELAY CONNECTION 5-10 REL #2-3 VIA COM 5-16 ALARM RELAY CONNECTION 5-10 CLEAR RECORDED VALUES 5-16 THERMAL RESET 5-10 FACTORY SETTINGS 5-16 ATTENTION

36 3-3 Functions Recorded Values Table 3.C Recorded Values Overview Display List Option Card Cat. No. Page Display List Option Card Cat. No. 825-M MAIN TIME h min. 7-2 CAUSE 2PRV TRIP 7-3 MOTOR RUNNING HR h min. 7-2 CAUSE 3PRV TRIP 7-3 SINCE LAST START h min. 7-2 CAUSE 4PRV TRIP 7-3 SINCE 1PRV START h min. 7-2 SINCE EMG START h min. 7-3 SINCE 2PRV START h min. 7-2 SINCE POWER OFF h min. 7-3 SINCE 3PRV START h min. 7-2 DURATION POW OFF h min. 7-3 SINCE 4PRV START h min. 7-2 I BEF LAST TRIP %, e 7-3 SINCE LAST TRIP h min. 7-2 AS BEF LAST TRIP % 7-3 Page SINCE 1PRV TRIP h min. 7-3 EF BEF LAST TRIP ma, %, e 7-3 SINCE 2PRV TRIP h min. 7-3 MAX T BEF LAST TRIP ºC 825-MMV 7-4 SINCE 3PRV TRIP h min. 7-3 TH BEF LAST TRIP % 7-4 SINCE 4PRV TRIP h min. 7-3 NUMBER START 7-4 CAUSE LAST TRIP 7-3 NUMBER TRIP (TH, AS, OC, EF, SC, UL, CAUSE 1PRV TRIP 7-3 PTC, PR, PL, PT100) 7-4

37 Functions 3-4 Operation Selecting the Setting/Display Mode SET Actual Change mode by pressing Set Recorded Values ACTUAL VALUES SET VALUES RECORDED VALUES Actual Change Actual Change Actual Change Indication of actual operational data Setting mode (set/vary, store parameters) Indication of statistical data

38 3-5 Functions Setting the Operation Parameters (Set Values) Figure 3.1 Setting Mode SET VALUES Actual Change Set Recorded Values Enter Select Settings Figure 3.2 Menu Selection 35 AMP FULL LOAD CURR Actual Change Set Recorded Values Enter Select Settings

39 Functions 3-6 Figure3.3 Entering a Data Value 35 AMP Actual Change Set Recorded Values Enter Select Settings Table 3.D Display Example of Set Values Menu LCD Range Description SET VALUES Mode: setting parameters FULL LOAD CURR 20 A Rated motor current in A PRIMARY C.T. NO No/Yes Primary current transformer in use PRIMARY C.T. RATIO Primary current transformer ratio LOCKED ROT CURR 6 x Ie Locked rotor current as, e LOCKED ROT TIME 10 sec Maximum permitted time for the rotor to be stalled from cold

40 3-7 Functions Indications of Actual Values Figure 3.4 Selecting the Actual Values ACTUAL VALUES Actual Change Set Recorded Values Enter Select Settings I MOTOR 00 % Ie Actual Change Set Recorded Values Enter Select Settings Table 3.E Display Example of Actual Values Menu LCD Range Description ACTUAL VALUES Display of the actual values I MOTOR A Motor current in A TH UTILIZ % Thermal utilization I MOTOR % Ie 0/ Motor current as percent of rated current

41 Functions 3-8 Applications Indications of Recorded Values (Statistics) Figure 3.5 Selecting Recorded Data RECORDED VAL Actual Change Set Recorded Enter Values Select Settings 2 h 28 min SINCE LAST TRIP Actual Change Set Recorded Values Enter Select Settings

42 3-9 Functions Table 3.F Display Example of Recorded Values LCD RECORDED VALUES Description Display of the statistical data 825-M MAIN TIME _ H _MIN Bulletin 825-M* running time (including interruption 8 hour of control voltage in hours, minutes) MOTOR RUNNING TIME _h _min Total motor running time in hours, minutes Applications Test Button Figure 3.6 Basic Unit Test Button SMART MOTOR MANAGER Change Test Enter Settings Reset

43 Functions 3-10 Testing the Thermal Trip TEST THERMAL ON LOCK ROT TIME _sec THERMAL TRIP Resetting Testing the Trips (Asymmetry/Unbalance, Underload, etc.) ASYMMETRY TRIP AUX RELAY #2

44 3-11 Functions ASYMMETRY TRIP NO OUTPUT RELAY TEST AS TRIP TIME _sec ASYMMETRY TRIP Resetting Testing the Warning Functions AS WARNING ALARM RELAY

45 Functions 3-12 TEST TEST AS WARNING Resetting

46 3-13 Functions Function Summary Table 3.G Protective Functions Summary Functions Factory Setting Setting Range Factory Setting Tripping Delay Range Factory Setting Selection Relays ➌ Factory Setting Bulletin 825-M Basic Unit Thermal overload On 100% MR, No MR Asymmetry (phase failure) On 5 80% 35% 1 25 s 2.5 s All MR High overloading/jam On 1 6, e 2.4, e s 0.5 s All MR Underload Off % 75% 1 60 s 10 s All MR Underload delayed enable On s 0 s Earth (ground) fault (residual) On % 50% s 0.5 s All MR Starting time monitor Off s 10 s All MR Limited starts per hour Off All MR Bulletin 825-MST Option Card Short-circuit Off 4 12, e 10, e ms 50 ms #1, No #1 Earth (ground) fault (core balance c.t.) Off 5 ma 50 A 1 A s 0.5 s All MR Stalling during start Off ➊ ➊ All ➊ MR ➊ Thermistor input (PTC) Off 800 ms All MR Bulletin 825-MLV Option Card Phase sequence (motor supply) Off 1 s All MR Phase failure (motor supply) Off 2 s All MR Bulletin 825-MMV Option Card PT100 input #1 #6 (RTD) (stator, bearings) Off C 50 C < 8 s MR, AL #1 #3 MR PT100 input #7 (RTD) ➋ Off ➊ ➋ ➌ Via external speedometer (control input #1), output and trip relays as for high overload. Allowing for the ambient temperature in the thermal image. Only one relay per function can be selected: MR = main relay, AL = alarm relay, auxiliary relay #1 #5 (if auxiliary relays #2 and #3 are assigned to the communication [refer to page 5-16] they cannot be selected here). ATTENTION

47 Functions 3-14 Table 3.H Warning Functions Summary Functions Factory Setting Setting Range Factory Setting Tripping Delay Range Factory Setting Relays ➊ Selection Factory Setting Bulletin 825-M Basic Unit Thermal utilization (%Δϑ load) Off 50 99% 75% AL, #1 5 AL Asymmetry (%, e ) Off 5 80% 20% AL, #1 5 AL High overloading (x, e ) Off 1 6, e 2, e AL, #1 5 AL Underload Off %➋ 75%➋ AL, #1 5 AL Bulletin 825-MST Option Card Earth (ground) fault (core balance c.t.) Off 5 ma 50 A 500 ma AL, #1 5 AL Bulletin 825-MMV Option Card PT100 input #1 #6 (RTD) (stator, bearings) Off C 50 C AL, #1 3 AL ➊ ➋ Only one relay per function can be selected: MR = main relay, AL = alarm relay, auxiliary relay #1 #5 (if auxiliary relays #2 and #3 are assigned to the communication [refer to page 5-16] they cannot be selected here). Same setting as for the Underload Trip function.

48 3-15 Functions Table 3.I Control Functions Summary Warm start (% of cold trip) Emergency override of thermal trip ➊ Analog output assigned to: thermal utilization PT100 max. temperature, Motor Functions Factory Setting Setting Range Factory Setting Bulletin 825-M Basic Unit Tripping Delay Range Off % 70% 4 60 min. ➋ Factory Relays Factory Setting Selection Setting 60 min. ➋ Bulletin 825-MST Option Card On 4 20 ma 0 100% C 0 200%, e Bulletin 825-MST Option Card, Control Input #1: (24V AC/DC; 8 ma) One of 3 functions can be selected: 1) Pickup delay, relay #2 Off s 1 s #2 1) Dropout delay, relay # s 2 s #2 2) Speed switch Off high overload relay 3) Disable protective functions: Asymmetry/phase failure Off High overload/jam Off Earth (ground) fault Off Short-circuit Off Underload Off Limiting starts/hour Off PTC Off PT100 (RTD) Off ➊ ➋ Terminals Y11 Y12 must be jumpered. Minimum waiting time between two warm starts.

49 Functions 3-16 Table 3.I Control Functions Summary (Continued) Functions Factory Setting Setting Range Factory Setting Tripping Delay Range Factory Relays Setting Selection Factory Setting Bulletin 825-MST Option Card, Control Input #2: (24V AC/DC; 8 ma) One of three functions can be selected: 1) Pickup delay, relay #3 Off s 1 s #3 1) Dropout delay, relay # s 2 s #3 2) Set second rated 0.5 current ➊ Off A 20 A 3) Disable protective functions: Asymmetry/phase failure Off High overload/jam Off Earth (ground) fault Off Short-circuit Off Underload Off Limiting starts/hour Off PTC Off PT100 (RTD) Off Bulletin 825-MLV Option Card Star-delta starting Off Y-Δ at 1.1, e Y-Δ at s 10 s Y: #4/Δ:#5 ➊ For example, when used with two-speed motors Functions of the Basic Unit (Cat. No. 825-M ) Thermal Overload

50 3-17 Functions Figure 3.7 Two-Body Simulation of the Heating Up of a Motor P Cu (I 2 M + ki G 2) R1 P Fe C1 C2 S1 R2 R3 ϑ amb C1 Capacitance representing the heat capacity of the winding (adjustable) C2 Capacitance representing the heat capacity of the iron an other masses of the machine R1 Resistance representing resistance to heat transfer between winding and iron R2 Resistance representing heat dissipation to the surroundings when stationary R3 Resistance representing heat dissipation to the surroundings when running P Cu Input of a current proportional to the copper losses P Fe Input of a current proportional to the iron losses S1 Changeover from stationary to running, M Motor current, G Opposing component caused by asymmetry ϑ amb Allowance for the temperature of the environment coolant (optional PT100 #7) k Constant factor according to IEC and NEMA Adjustable Ratio of Cooling Constants

51 Functions 3-18 Indication of the Time to Tripping TRIP IN sec Indication of the Time until the Thermal Trip can be Reset RESET IN sec Adjustable Setting Characteristic

52 3-19 Functions Figure 3.8 Trip Characteristic (10 30 s) From cold, without pre-load 10s 20s 30s Trip time [s] s 20s 30s From warm, pre-load 1xIe Load current as multiple of full load current nxie

53 Functions 3-20 Figure 3.9 Trip Characteristics ( s) From cold, without pre-load s 60s 100s Trip time [s] s 60s 100s From warm, pre-load 1xI e Load current as multiple of full load current. nxie

54 3-21 Functions Table 3.J Thermal Overload Setting Parameters Detection Module ➋ 825-MCM2 825-MCM MCM MCM MCM630N Rated Current Setting range A ➊ A ➊ A A ➌ A Factory setting 20 A 20 A 20 A 20 A 20 A Setting increments A A 1 A 2 A 2 A Locked-Rotor Current (Multiple of Rated Current) Setting range , e Factory setting 6, e Setting increments 0.1, e Locked-Rotor Time (Admissible Locked-Rotor Time of Cold Motor) Setting range s Factory setting 10 s Setting increments 1 s Cooling Factor of Motor Off/On ➍ Setting range 1 10 Factory setting 2.5 Setting increments 0.5 Resetting the Thermal Trip Setting range % of thermal utilization Factory setting 50% Setting increments 1% Ultimate Release Current Incl. setting tolerance , e ➊ ➋ ➌ ➍ Up to A, if primary current transformers are used C ( F) UL/CSA A The cooling factor can be modified to reflect different motor cooling with running motor and at standstill.

55 Functions 3-22 Table 3.K Protection Against Thermal Overload Warning Trip Function Factory setting Off On Response Level ➊ Setting range 55 99% Factory setting 75% 100% Setting increments 1% Output Relay ➋ Selection AL, #1 #5 MR, No output relay Factory setting AL MR ➊ Thermal utilization % ➋ If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. Asymmetry (Phase Unbalance) and Phase Failure P (, 2 Cu M + k, 2 G) ΔU (%) Max. deviation from the average of the phase voltages 100 = Average of the phase voltages

56 3-23 Functions Figure 3.10 Reduction in Permissible Motor Output Due to Voltage Asymmetry per IEC and NEMA f R f R Reduction factor for motor output ΔU Voltage asymmetry in percent 0.8 ΔU [%] Table 3.L Asymmetry (Phase Unbalance) Setting Parameters Warning ➊ (Current Asymmetry) Trip ➊ Function Factory setting Off On Response Level Setting range 5 80% 5 80% Factory setting 20% 35% Setting increments 5% 5% Tripping Delay Setting range 1 25 s ± 0.2 s Factory setting 2.5 s ± 0.2 s Setting increments 0.5 s Output Relay ➋ Selection (relays) AL, #1 #5 MR, AL, #1 #5 Factory setting AL MR ➊ ➋ 5 60 C (2 140 F) If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. High Overload and Jam

57 Functions 3-24 Application Figure 3.11 Function of High Overload and Jam Protection I Ie t v t Motor start, 1.2, e t V Tripping delay 2 Nominal operation 4 Jam protection not active 3 High overload or jam 5 Jam protection active (tripping threshold) Table 3.M High Overload and Jam Setting Parameters Warning ➊ Trip ➊ Function Factory setting Off On Response Level Setting range 1 6, e 1 6, e Factory setting 2, e 2.4, e Setting increments 0.2, e 0.2, e Tripping Delay Setting range s ± 0.04 s Factory setting 0.5 s ± 0.04 s Setting increments 0.1 s Output Relay ➋ Selection (relays) AL, #1 #5 MR, AL, #1 #5 Factory setting AL MR ➊ ➋ 5 60 C ( F) If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here.

58 3-25 Functions ATTENTION Underload Application

59 Functions 3-26 Figure 3.12 Function of Underload Protection I I e I 1 I e I T t A t p t v t t s t p 1 Start, r Tripping threshold 2 Nominal operation t s Delayed activation (underload 3 Underload operation protection not active) t A Starting time t v Tripping delay, e Rated current t p Warning Table 3.N Underload Setting Parameters Warning ➊ Trip ➊ Function Factory setting Off On Response Level Setting range ➋ %, e Factory setting ➋ 75% Setting increments ➋ 5% Tripping Delay Setting range 1 60 s -0.2 s/+0.4 s Factory setting 10 s Setting increments 1 s Delayed Activation of Underload Protection Setting range s +0.4 s/+0.8 s Factory setting 0 s Setting increments 1 s Output Relay ➌ Selection (relays) AL, #1 #5 MR, AL, #1 #5 Factory setting AL MR ➊ ➋ ➌ 5 60 C ( F) For warning, the set Response Level is the same as the level set for tripping. If the starting current is below 1.2 FLC, then the Monitoring the Start Time function must be activated. After the set max. starting Time has elapsed, the High Overload/Stall function will become active. If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here.

60 3-27 Functions Earth (Ground) Fault Earth (Ground) Fault Protection by the Holmgreen Method = Residual Method (Solidly Earthed Networks), Figure Phase Current Detection Measurement of the neutral current, 0 in the neutral connection of the current transformer to detect an earth (ground) fault (residual circuit) L1 L2 L3 P1 S1 P1 S1 P1 S MCM 825-M P2 S2 P2 S2 P2 S2 I 0 M1 3 ~

61 Functions 3-28 Table 3.O Earth (Ground) Fault Holmgreen/Residual Setting Parameters Trip ➊ Function Factory setting On Response Level Setting range % Factory setting 50% Setting increments 10% Tripping Delay Setting range s ± 0.4 s Factory setting 0.5 s Setting increments 0.1 s Output Relay ➋ Selection (relays) MR, AL, #1 #5 Factory setting MR ➊ ➋ 5 60 C ( F) If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. Earth (Ground) Fault Protection with a Core Balance Current Transformer Figure 3.14 Example of 2-Phase Current Sensing Example of 2-phase current detection and core balance current transformer for sensitive earth (ground) fault protection (3-phase current detection is also possible) L1 L2 L3 P1 S1 P1 S MCM M P2 S2 P2 S2 3 4 S1 S2 M1 3 ~

62 3-29 Functions Table 3.P Core Balance Current Transformer Setting Parameters Current Ratio Setting range Factory setting 100 Setting steps 1 Table 3.Q Earth (Ground) Fault Core Balance Setting Parameters Warning ➊ Trip ➊ Function Factory setting Off On Response Level Setting range 5 ma 50 A 5 ma 50 A Factory setting 500 ma 1.0 ma Setting increments 5 ma 0.25 A Tripping Delay Setting range s ± 0.04 s Factory setting 0.5 s Setting increments 0.1 s Output Relay ➋ Selection (relays) AL, #1 #5 MR, AL, #1 #5 Factory setting AL MR ➊ ➋ 5 60 C ( F) If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. Earth (Ground) Fault Protection in High-Voltage Systems μ μ

63 Functions 3-30 Isolated or High-Impedance Earth Networks Neutralized Networks

64 3-31 Functions Schematic Representation of Various Network Configurations and Earth (Ground) Fault Locations, Figure 3.15 Isolated Network: Earth Fault on the Network Side The basic unit measures the earth current component through C M. T K1 825-M M1 3 AC U2 U1 CN IE CM U3 Figure 3.16 Network Earthed through a High Impedance: Earth Fault on the Network Side The basic unit measures the earth current component through C M. Compensated network: Through the fault a small current flows, given by the vector sum of the earth currents. T K1 825-M M1 3 AC U2 U1 U3 L R CN I E CM

65 Functions 3-32 Figure 3.17 Isolated network: Earth (Ground) Fault on the Leads on the Motor Side The basic unit measures the earth current component through C M. T K1 825-M M1 3 AC U2 U1 U3 CN I E CM Figure 3.18 Network Earthed through a High Impedance: Earth (Ground) Fault on the Motor Leads The basic unit measures the vector sum of the earth currents through C N and the earthing resistance R. Compensated network: The basic unit measures the vector sum of the earth currents through C N and the compensating coil L. T K1 825-M M1 3 AC U2 U1 U3 L R CN I E CM Figure 3.19 Isolated Network: Earth (Ground) Fault in the Motor The nearer the fault is to the motor star-point, the smaller the fault current. T K1 825-M M1 3 AC U2 U1 CN CM IE U3 Figure 3.20 Network Earthed through a High Impedance: Earth (Ground) Fault on the Motor The basic unit measures vector sum of the earth currents through C N and the earthing resistance R. Compensated network: The basic unit measures the vector sum of the earth currents through C N and the compensating coil L. The nearer the fault is to the motor star-point, the smaller the fault current. T K1 825-M M1 3 AC U2 U1 L R CN CM I E U3

66 3-33 Functions Limiting the Number of Starts per Hour (Start Lockout) Function Figure 3.21 Limiting the Number of Starts per Hour I Ie I I e I II, First start,, Second start t w The selected relay (MR, or #1 #5) remains in the tripped position until 60 min. have expired. If an additional start is allowed, the number of starts can be increased by one. Table 3.R Starts per Hour Setting Parameters Function Factory setting Off Setting Setting range 1 10 starts/hour Factory setting 2 starts/hour Setting increments 1 Output Relay ➊ Selection (relays) MR, AL, #1 #5 Factory setting MR ➊ If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. t w t 60 min. ATTENTION

67 Functions 3-34 Monitoring the Starting Time Function,, Applications Figure 3.22 Monitoring Starting Time I 1.2 Ie Ie 2 t tv 1 Motor starting current 1.2, e 2 Rated conditions t V Max. starting time 3 Tripping if starting lasts too long

68 3-35 Functions Table 3.S Monitoring Start Time Setting Parameters Function Factory setting Max. Starting Time ➊ Setting range Factory setting Setting increments Output Relay ➋ Selection (relays) Factory setting Off s ± 0.04 s 10 s ± 0.04 s 1 s MR, AL, #1 #5 MR ➊ ➋ 5 60 C ( F) If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. Warm Start Function

69 Functions 3-36 Figure 3.23 Current and Temperature Curves for Warm and Cold Motor Starts and the Smart Motor Manager Tripping Limits I A I I e ϑ ϑ 1 ϑ e t t t 1 t w t w t w, A Starting current 1 First start (cool), e Rated current 2 First warm start ϑ e Permissible temperature 3 Second warm start of the motor in conti- 4 Cold start (after the motor nuous operation and has cooled down) normal tripping limit t 1 Minimum time before first of 825-M for continuous start is possible operation (t1 > 10t 6,e) ϑ1 Motor temperature t w Minimum waiting time permissible for a short warm starts (4 60 min.) time and tripping limit of 825-M with modified characteristic for warm start ATTENTION

70 3-37 Functions Applications Figure 3.24 Example for t6x, e = 10 s and Warm Trip Time = 70% a Trip Time [s] c d b nxi e Load Current as Multiple of Full Load Current a) Time/current characteristic from cold when setting the trip time t6x, e = 10 s. b) Time/current characteristic after preloading with 1x, e when the trip time from cold t6x, e = 10 s and WARM START function is disabled. c) Time/current characteristic after preloading with 1x, e (thermal utilization or winding temperature = 82%) when the trip time from cold t6x, e = 10 s and WARM START function is enabled, setting: WARM TRIP TIME = 70% of the trip time from cold. (The WARM TRIP TIME 7.3 s for 6x, e is higher than (70% x 10) = 7 s because it depends on the winding and iron temperature which are not at their highest value.) d) If the thermal utilization (winding temperature) is higher than 82%, the WARM START function is automatically disabled. If lower than 82% the WARM TRIP TIME depends on the winding and iron temperature and its range is s.

71 Functions 3-38 Table 3.T Warm Start Setting Parameters Function Factory setting Off Tripping Time from Warm State as a Percentage of Tripping Time from Cold State Setting Setting range % Factory setting 70% Setting steps 10% Minimum Time Between Two Warm Starts Setting Setting range 4 60 min. Factory setting 60 min. Setting steps 1 min. Emergency Override of Thermal Trip (Emergency Start) Suggested Procedure ATTENTION

72 3-39 Functions SET VALUES PTC TRIP OFF PT100 #1 6 TRIP OFF LED Alarm and Trip Indicator

73 Functions 3-40 Connection of the Main Relay (MR) Electrically Held Mode Supply Off Supply On Supply On and Trip Non-Fail-Safe Mode Supply Off Supply On Supply On and Trip Applications of the Non-Fail-Safe Connection Connection of the Alarm Relay (AL)

74 3-41 Functions Electrically Held Mode Supply Off Supply On Supply On and Warning Non-Fail-Safe Mode Supply Off Supply On Supply On and Warning Applications of the Electrically Held Connection Alarm Relay AL Table 3.U Alarm Examples Warning Factory Setting Thermal Utilization 75% Asymmetry 20% High Overload 2, e Underload 75% All these functions Off

75 Functions 3-42 Reset Kinds of Reset Reset Conditions Table 3.V Reset Setting Parameters Setting range Manual/Automatic Factory setting Manual Reset Threshold of the Thermal Trip Setting range % Factory setting 70% Setting increments 5% Function of the Cat. No. 825-MST Option Card Short-Circuit

76 3-43 Functions Figure 3.25 Interruption of a Short-Circuit 12 I e I A I e 825-M Relais #1 I t Q1M Circuit-breaker (tripping relay), Current curve, A Pickup value, e Rated service current t v Tripping delay 50 ms t Q Operating time of the breaker t LB Arc duration 1 Short-circuit 2 Contact separation 3 Short-circuit interruption t BL Relay MR blocked at 12, e Relais MR Q1M t v t Q t LB t BL Application ATTENTION

77 Functions 3-44 Table 3.W Short Circuit Setting Parameters Trip ➊ Function Factory setting Off Response Level Setting range 4 12, e Factory setting 10, e Setting increments 0.5, e Tripping Delay Setting range ms Factory setting 50 ms Setting increments 10 ms Output Relay Selection (relays) #1, No output relay Factory setting #1 ➊ 5 60 C ( F) Earth (Ground) Fault Protection with a Core Balance Current Transformer Stalling During Start Function

78 3-45 Functions Applications Figure 3.26 Stalling During Starting I e I I Normal start without hindrance by high overload or stalling 2 Stalling during standing t v Tripping delay I e t t v Table 3.X Stalling during Start Setting Parameters Trip Function Factory setting Off Tripping Delay The trip time t Factory setting sp depends on the trip time t ov chosen for the overcurrent as follows: t ov <400 ms, t sp = 600 ms.; t ov 400 ms, t sp = t ov ms. Actuation Message from zero speed switch to control input #1 Motor running 24V AC/DC at control input #1 Motor standstill 0V AC/DC at control input #1 Output Relay Same relay as for function High Overload and Jam Selection (relays) (settable only there)

79 Functions 3-46 PTC Thermistor Input Function Applications Table 3.Y PTC Setting Parameters Factory setting Selection (relays) Factory setting Function Output Relay ➊ Off MR, AL, #1 #5 MR ➊ If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here.

80 3-47 Functions Table 3.Z Sensor Measuring Circuit Specifications Function Factory setting Off Sensor Measuring Circuit Max. resistance of the PTC chain when cold 1.5 kω Max. number of sensors as per IEC Pickup value at δ A = C 3.3 kω ±0.3kΩ Dropout value at δ A = C 1.8 kω ±0.3kΩ Delay on pickup 800 ms ± 200 ms Pickup value when short-circuit in sensors circuit at δ A = C 15 Ω Measuring voltage as per IEC < 2.5V DC Measuring Lead Minimum cross-section [mm 2 ] [AWG No.] Maximum length [m] [ft] Method of installation ➊ up to 100 m (328 ft) twisted, unscreened ➊ Twisted lead: 25 times twisted per m Screened lead: Screen connected to T2

81 Functions 3-48 Figure 3.27 Characteristic of PTC Sensors as per IEC R [Ω] TNF R [Ω] C 0 C TNF-20K TNF- 5K Nominal pickup temperature Resistance to sensors TNF+15K TNF+ 5K TNF Analog Output Specifications Output Load 4 20 ma (IEC 381-1) at C ( F) Ω Analog Output for Thermal Load or Motor Temperature (PT100 Max.)

82 3-49 Functions Application Figure 3.28 Analog Output for Motor Temperature Rise ϑ ϑ max ϑ G ϑ K ( ma ± 4 ma) Therm utiliz (%) = 100% 16 ma ma ϑ Temperature rise of motor ϑ max Permissible temperature limit (tripping threshold) ϑ G Nominal temperature (load, e ) ϑ K Coolant temperature (40 C or via PT100 #7)

83 Functions 3-50 Figure 3.29 Analog Output for Motor Temperature ϑ 200 C 50 C ( ma ± 4 ma) Motor temp. ( C ) = 150 C 16 ma ma 4 Analog Output for Motor Current Figure 3.30 Analog Output for Motor Current % I e Motor current (%, e ) ( ma ± 4 ma) = 200%, 16 ma e ma

84 3-51 Functions Control Inputs #1 and #2 Actuation Input #1 Input #2 Y31 (+) Y32 (-) Y41 (+) Y42 (-) 24V AC or 24V DC; 8 ma Pick values: On: V Off: < 2 V Timer Functions Assignment of the Output Relays

85 Functions 3-52 Figure 3.31 Operating Diagram for Timer Functions Control input > 0.5 s Output relay On-delay t on t off = 0 Off-delay t on = 0 t off On-off-delay t on t off On-off-delay t on t off Applications Lock-Out of Protection Functions Applications

86 3-53 Functions Switching to a Second Rated Current Application Functions of the Cat. No. 825-MLV Option Card Phase Sequence Function Applications

87 Functions 3-54 Table 3.AA Phase Sequence Setting Parameters Factory setting Factory setting Selection (relays) Factory setting ➊ Function Tripping Delay Output Relay ➊ If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. Off 1 s MR, AL, #1 #5 MR ATTENTION Phase Failure (Based on Voltage Measurement) Function Table 3.AB Phase Failure Setting Parameters Factory setting Factory setting Selection (relays) Factory setting Function Tripping Delay Output Relay ➊ Off 2 s MR, AL, #1 #5 MR ➊ If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here.

88 3-55 Functions Star-Delta (Wye-Delta) Starting Figure 3.32 Diagram of Star-Delta (Wye-Delta) Starting Motor Motor current on off I I e Ι e Star operation, relay #4 t Delta operation, relay #5 Changeover delay 80 ms 80 ms Table 3.AC Star-Delta (Wye-Delta) Starting Setting Parameters Setting Star (Wye) Relay Delta Relay Max. Star (Wye) Operation Function Factory setting Off Off Setting Setting range s Factory setting Relay #4 Relay #5 10 s Setting steps 1 s

89 Functions 3-56 Functions of the Cat. No. 825-MMV Option Card PT100 (100 Ω Platinum) Temperature Sensor (RTD) Ω Table 3.AD PT100 Temperature Detector Resistance per IEC 751 Applications Temperature ( C Resistance (Ω)

90 3-57 Functions Table 3.AE PT100 (RTD) Setting Parameters Warning Trip Function Factory setting Off Off Response Level Setting range C C Factory setting 50 C Setting steps 1 C Tripping Delay Factory setting < 8 s < 8 s Output Relay ➊ Selection (relays) AL, #1 #3 MR, AL, #1 #3 Factory setting AL MR ➊ If auxiliary relays #2 and #3 are assigned to the communication (refer to page 5-16) they cannot be selected here. ATTENTION PT100 #7 Temperature Sensor (RTD) PT100 PROT ON Tambient C

91 Functions 3-58 Tamb IN TH IMAGE ON MOTOR INSULATION CLASS B Table 3.AF Motor Insulation Class Setting Parameters Factory setting Selection Factory setting Application Function Insulation Class Off B, E, F B

92 Chapter 4 Assembly and Installation Assembly Flush Mounting Figure 4.1 Basic Unit Mounted in an Enclosure ➊ 138 mm ➋ 10 mm (3/8") (5-7/16" ) + 1/16-0 max. 6 mm (1/4") ➌ Alarm Actual Test Values Select Settings Reset Set Recordet Trip 144 mm (5-11/16") Change Enter 144 mm (5-11/16") 138 mm (5-7/16" + 1/16 ) - 0 Dimensions in mm (inches) Dimensions: Panel cutout: 138 x 138 mm (-0 mm, +1 mm) Mounting depth: min. 140 mm ➊ Front panel with cutout ➋ Rubber gasket ➌ Fixing nuts

93 Actual Set Recordet Trip 90 Assembly and Installation 4-2 Mounting Position Figure 4.2 Mounting Position SMART MOTOR MANAGER 22.5 Surface Mounting Figure 4.3 Basic Unit Mounted into Panel Mounting Frame (Cat. No. 825-FPM) Hinge mm (6-11/16") Ø 6.5 mm (1/4") 150 mm (5-7/8") 170 mm (6-11/16") Alarm 170 mm (6-11/16") 165 mm (6-1/2") Test Values Select Settings Reset Change Enter Dimensions in mm (inches)

94 4-3 Assembly and Installation Converter Modules Figure 4.4 Cat. Nos. 825 MCM2, 825-MCM-20, 825-MCM180 ø d ø e d1 d3 b b ➌ ➊ e2 d2 a e2 c1 c ➋ Table 4.A Cat. Nos. 825 MCM2, 825-MCM-20, 825-MCM180 Cat. No MCM2 MCM20 MCM180 a b c c1 d d1 d2 d3 e e1 e2 b1 b2 120 (4-45/64) 120 (4-45/64) 120 (4-45/64) (3-23/64) (4) (3-23/64) (4) 102 (4) 66 (2-39/64) 66 (2-39/64) 72 (2-13/16) 5.3 (3/16) 5.3 (3/16) 5.3 (3/16) 5.3 (3/16) 5.3 (3/16) 5.3 (3/16) ➊ Mounted on DIN Rail EN ➋ Bus bar or opening for conductor max. 19 mm ➌ With Cat. No. 825-MVM ➍ With Cat. No. 825-MVM2 100 (3-7/8) 100 (3-7/8) 100 (3-7/8) Figure 4.5 Cat. Nos. 825-MCM630, 825-MCM630N 55 (2-3/16) 55 (2-3/16) 55 (2-3/16) 2 x 2.5 mm (1-1/2) 2 x 2.5 mm (1-1/2) M8 M (1-1/2) 75 (2-61/64) ➌➍ 100/117 ø e ø d d3 b d1 e2 d2 a e2 ø e1 c1 c

95 Assembly and Installation 4-4 Table 4.B Cat. Nos. 825-MCM630, 825-MCM630N Cat. No. a b c c1 d d1 d2 d3 e1 e2 825-MCM (6-7/64) 145 (5-11/16) 156 (6-1/8) 118 (4-5/8) 6.3 (1/4) 6.3 (1/4) 135 (5-5/16) 88 (3-7/16) M10 48 (1-7/8) 825-MCM630N 155 (6-7/64) 145 (5-11/16) 177 (6-31/32) 118 (4-5/8) 6.3 (1/4) 6.3 (1/4) 135 (5-5/16) 88 (3-7/16) M10 48 (1-7/8) Thermal Utilization Indicator Figure 4.6 Cat. No. 825-MTUM Thermal Utilization Indicator Panel cutout: 91.5 x 91.5 mm (3-39/64" x 3-39/64") ( 1 mm [ 1/16"] mm [+1/32"]) Mounting depth: 55 mm (2-3/16") Wire size: 2 x 2.5 mm 2 (14 AWG) ATTENTION

96 CPB4 4-5 Assembly and Installation Figure 4.7 Basic Unit Housing with Option Cards ➊ ➊ ➋ ➌ ➍ ➎ ➏ ➐ Basic Unit housing Cat. No. 825-MMV or 825-MLV option card Communication board Cat. No. 825-MST option card Board with basic unit Rear cover Screws CMV4/CLV4 CST4 Basic ➋ ➌ ➍ ➎ ➐ ➏ Installation and Wiring General ATTENTION

97 Assembly and Installation 4-6 Main Circuits Basic Unit and Converter Module without Main Current Transformer Figure 4.8 Basic Unit with Converter Module L1 L2 L MCM Cable with plugs 825-M Converter module cat. nos. 825-MCM2 825-MCM MCM MCM MCM630N M 3 ~ Basic Unit and Converter Module with Main Current Transformer Figure Phase Current Evaluation L1 L2 L MCM 825-M Converter module 825-MCM2 825-MCM20 Main current transformer A/5 or A/1 A For selection, refer to Chapter 2. M 3~

98 4-7 Assembly and Installation Basic Unit and Converter Module with Main and Core Balance Current Transformer Figure Phase Current Evaluation L1 L2 L3 Converter module cat. nos. 825-MCM2 825-MCM T1 825-MCM 825-M k l T2 Σ M 3~ Table 4.C Specifications Main current transformer (refer to Chapter 2 for selection information) A/5 A or A/1 A Core Balance Current Transformer Earth-/ground current 5 ma 50 A Current ratio of core balance current transformer :1 Output from core balance current transformer ma

99 Assembly and Installation 4-8 Control Circuits Figure 4.11 Smart Motor Manager Basic Unit Supply: A1 - A1 + Supply AC or DC No fuse needed Emerg. Start Disable Settings Y11 Y12 Y13 Emergency override of thermal trip (Emergency start): Push button, key-switch Disable settings and keys: ➊ Wire jumper, switch, key-switch Remote Reset Y21 Y22 Remote reset: ➋ Push button, key-switch Alarm relay AL, non-fail-safe connection (Factory setting) IEC 400V AC/125V DC UL/CSA 240V AC/125V DC Alarm relay AL, electrically held connection (from V2.18, selectable) IEC 400 VA/125V DC UL/CSA 240V AC/125V DC Output relay MR in electrically held connection (Factory setting) IEC 400V AC/125V DC UL/CSA 240V AC/125V DC Output relay MR in non-fail-safe connection IEC 400V AC/125V DC UL/CSA 240V AC/125V DC 96 External Internal ➊ ➋ Setting via communication is also disabled, as well as Test and Reset The remote reset is always active

100 4-9 Assembly and Installation Figure 4.12 Cat. No. 825-MST Option Card Aux Relay #1 Auxiliary relay #1 IEC 400V AC/125V DC UL/CSA 240V AC/125V DC Aux Relay #2 Auxiliary relay #2 50V AC/30V DC A ma ( W) Aux Relay #3 I + I - Auxiliary relay #3 50V AC/30V DC Analog output indicates the thermal utilization of the motor, the motor temperature, or the motor current Indicating instrument PLC input Recorder Control Input #1 Control Input #2 PTC L1 L2 L3 Y31 Y32 Y41 Y42 T1 T2 k Control input #1: 24V DC or 24V AC ➊ Control input #2: 24V DC or 24V AC ➊ Thermistor overtemperature protection max. 6 PTC wired in series Measuring lead ➋ Min. cross-section [mm 2 ] [AWG No.] Max. length [m] [ft] Core balance transformer ma at k-l l External Internal ➊ For information regarding methods of actuation, refer to Chapter 9. ➋ Method of installation: up to 100 m (328 ft) twisted, more than 100 m additional unscreened

101 Assembly and Installation 4-10 Figure 4.13 Cat. No. 825-MLV Option Card ATTENTION F Aux Relay #4 Aux Relay #5 L1 L2 L3 Auxiliary relay #4 IEC 400 VAC/125 VDC UL/CSA 240 VAC/125 VDC Auxiliary relay #5 IEC 400 VAC/125 VDC UL/CSA 240 VAC/125 VDC Phase sequence protection Phase failure protection as per IEC, SEV VAC as per UL, CSA VAC MCM M 3 ~ External Internal T F L1 T F L1 L2 L2 L3 L MCM 825-MCM M 3 ~ M 3 ~ External Internal External Internal Supply voltage > 400 VAC (UL, CSA > 240 VAC) Supply voltage > 400 VAC (UL, CSA > 240 VAC)

102 4-11 Assembly and Installation Figure 4.14 Cat. No. 825-MMV Option Card ATTENTION PT100 #1 1T1 1T3 1T2 PT100 inputs #1 #6 (RTD) for monitoring the temperature of the stator winding and motor bearings. PT100 #2 2T1 2T3 2T2 PT100 #3 3T1 3T3 3T2 PT100 #4 4T1 4T3 4T2 PT100 #5 PT100 #6 PT100 #7 5T1 5T3 5T2 6T1 6T3 6T2 7T1 7T3 7T2 PT100, #7 for indication and inclusion of the coolant/ambient temperature (cooling air) in the thermal image. If PT100 #7 is not connected, then a resistance of 120 Ω should be connected between T1 and T3. Tamb IN TH IMAGE OFF Method of Installation

103 Assembly and Installation 4-12 Option Communication ATTENTION

104 Chapter 5 Setting the Operational Parameters Menu Overview ATTENTION Main Settings Table 5.A Main Settings Parameter Setting range Factory setting Rated motor current or service current, e A 20 A Current ratio of primary current transformer ➊ Locked-rotor current , e 6, e Locked-rotor time ➋ s 10 s ➊ ➋ Accessing this parameter requires that the parameter Primary CT be set to yes. If, instead of the permissible locked-rotor time, the maximum starting time is known, the approximate locked-rotor time is calculated as follows: Starting time Locked-rotor time

WIO200A Water in oil sensor

WIO200A Water in oil sensor WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic

Læs mere

MS-H280-Pro Magnetic Stirrer

MS-H280-Pro Magnetic Stirrer MS-H280-Pro Magnetic Stirrer www..com Copyright: No part of this manual may be reproduced or transmitted without prior written permission of. VERSION201407 CONTENTS Chapter 1: Working Principle... 3 1

Læs mere

TDC 4 Indoor voltage transformers

TDC 4 Indoor voltage transformers Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,

Læs mere

Constant Terminal Voltage. Industry Workshop 1 st November 2013

Constant Terminal Voltage. Industry Workshop 1 st November 2013 Constant Terminal Voltage Industry Workshop 1 st November 2013 Covering; Reactive Power & Voltage Requirements for Synchronous Generators and how the requirements are delivered Other countries - A different

Læs mere

WIO200A INSTALLATIONS MANUAL Rev Dato:

WIO200A INSTALLATIONS MANUAL Rev Dato: WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of

Læs mere

UNISONIC TECHNOLOGIES CO.,

UNISONIC TECHNOLOGIES CO., UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output

Læs mere

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications

RAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications RAVE The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications Product Presentation RAVE radar motion sensor In addition to the RaDec and RMS product families, the new RAVE radar

Læs mere

Metal Oxide Varistor:TVM-B Series

Metal Oxide Varistor:TVM-B Series Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction

Læs mere

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation PEMS RDE Workshop AVL M.O.V.E Integrative Mobile Vehicle Evaluation NEW - M.O.V.E Mobile Testing Platform Key Requirements for Measuring Systems Robustness Shock / vibrations Change of environment Compact

Læs mere

4-POLE MAGNETIC CONTACTORS

4-POLE MAGNETIC CONTACTORS 4-POLE MAGNETIC CONTACTORS FRAME SIZE OVERVIEW 18AF P/N: MRC-9B/4~MRC-18B/4 9 18 Amp Rating Inductive/Standard Contactor Coil 225AF P/N: MRC-100A/4~MRC-225A/4 100 225 Amp Rating Electronic Contactor Coil

Læs mere

Programmable pressure transmitters PTM

Programmable pressure transmitters PTM Programmable pressure transmitters PTM Version: 07.01.2016 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure

Læs mere

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package High Speed LDO Regulators, High PSRR, Low noise, Series General Description The series are highly accurate, low noise, CMOS LDO Voltage Regulators. Offering low output noise, high ripple rejection ratio,

Læs mere

Slot diffusers. Slot diffusers LD-17, LD-18

Slot diffusers. Slot diffusers LD-17, LD-18 LD-17, LD-18 Application LD-17 and LD-18 are designed for supply of cold or warm air in rooms with a height between. m and 4 m. They allow easy setting of air deflectors for different modes of operation

Læs mere

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080)

Uni-Valve A /S. UNI-EL Elektrisk aktuator Electric actuator UNI-EL 0020 - UNI-EL 0080. Tekniske data. Technical data (UNI-EL-0020, 0040, 0080) Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Elektrisk aktuator Electric actuator Tekniske data Technical data

Læs mere

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals Solenoid valves Control valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)1-73-0 Fax: +49(0)1-73-281 e-mail: info@akmueller.de Internet: www.akmueller.de

Læs mere

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS). Bilag 8. TDC technical requirements for approval of splitters and inline s intended for shared access (ADSL or VDSL over POTS). Dette bilag udgør bilag 8 til det mellem parterne tiltrådte Produkttillæg

Læs mere

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax TM4 Central Station User Manual / brugervejledning K2070-EU STT Condigi A/S Niels Bohrs Vej 42, Stilling 8660 Skanderborg Denmark Tel. +45 87 93 50 00 Fax. +45 87 93 50 10 info@sttcondigi.com www.sttcondigi.com

Læs mere

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting LED Drivers CV EASYLINE CV 48 V EasyLine 48 V C-L 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V C-L VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT POWER

Læs mere

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating

Varenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med

Læs mere

Technical Specifications

Technical Specifications Technical Specifications Pressure measuring range (bar) 0.1... 0.5, (1) > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar > 200 bar Accuracy, (5), (± % FS)

Læs mere

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support: Industrial flexible rubber cable range with an insulation and sheath in elastomers. Cables for heavy duty uses, Oil resistant and Flame retardancy according to IEC/EN 60332-1-2 standard. BESKRIVELSE Application

Læs mere

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 DK: Davo-Meg 1002: 87 98 301 819 Davo-Meg 1002B: 87 98 301 822 EAN: Davo-Meg 1002: 5703534100059 Davo-Meg 1002B: 5703534100202 Indhold

Læs mere

Lithium-Ion Jump-Starters / Jumper Cables

Lithium-Ion Jump-Starters / Jumper Cables AUTOMOTIVE Lithium-Ion Jump-Starters / Jumper Cables Lithium-Ion Jump-Starter 1300: Part No. DRLJS130 1300 4 6 8 cylinder (6 liter gas 3 liter diesel) SafeJump technology prevents sparking and protects

Læs mere

DX-610/DX-626 6CH.DMX DIMMER PACK

DX-610/DX-626 6CH.DMX DIMMER PACK DX-610/DX-626 6CH.DMX DIMMER PACK User Manual Lite Puter Enterprise Co., Ltd. Website: E-mail sales@liteputer.com.tw 1 DX-610/626 [EUM-I] INDEX SAFETY INTRODUCTION...2 The Load Power...2 Working Environment...2

Læs mere

Fundamentals of HVAC Control Systems

Fundamentals of HVAC Control Systems ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 4 Sensors and Auxiliary Devices 2007 ASHRAE Hong

Læs mere

Parts List MAJOR Overview. Table of Contents. Topic. This publication contains the following topics:

Parts List MAJOR Overview. Table of Contents. Topic. This publication contains the following topics: No: 8860 En Revision.0 0 05 Parts List MAJOR 80.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 303-35 85 86 3 33 3 35 36 37 38 83 39 0 8 N 68 7

Læs mere

frame bracket Ford & Dodge

frame bracket Ford & Dodge , Rev 3 02/19 frame bracket 8552005 Ford & Dodge ITEM PART # QTY DESCRIPTION 1 00083 8 NUT,.50NC HEX 2 00084 8 WASHER,.50 LOCK 3 14189-76 2 FRAME BRACKET 4 14194-76 1 411AL FRAME BRACKET PASSENGER SIDE

Læs mere

Delta Elektronik A/S - AKD

Delta Elektronik A/S - AKD Delta Elektronik A/S - AKD Hardware og type oversigt Grundlæggende oplysninger med forbindelser Opsætning af IP adresser på drev alle muligheder Gennemgang af WorkBench Up/Down load parametre filer Mest

Læs mere

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

Portal Registration. Check Junk Mail for activation  . 1 Click the hyperlink to take you back to the portal to confirm your registration Portal Registration Step 1 Provide the necessary information to create your user. Note: First Name, Last Name and Email have to match exactly to your profile in the Membership system. Step 2 Click on the

Læs mere

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. 67436 05/15 (OSH) 2015 OJ Electronics A/S

INSTRUKTION. OJ-DV Hterm. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. 67436 05/15 (OSH) 2015 OJ Electronics A/S INSTRUKTION 67436 05/15 (OSH) 2015 OJ Electronics A/S OJ-DV Hterm OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS GENERELT OJ-DV Hterm er en håndbetjeningsenhed, som anvendes til indstilling

Læs mere

WI180C-PB. Online-datablad

WI180C-PB. Online-datablad Online-datablad A B C D E F H I J K L M N O P Q R S T Oversigt over tekniske data Tekniske data Tilbehørsfamilie Henvisning Kapslingsklasse Dimensioner (B x H x L) Beskrivelse Klassifikationer Bestillingsoplysninger

Læs mere

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

Unitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Unitel EDI MT940 June 2010 Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Contents 1. Introduction...3 2. General...3 3. Description of the MT940 message...3 3.1.

Læs mere

Hudevad P200. Technical datasheet

Hudevad P200. Technical datasheet Technical datasheet Key benefits Low, streamlined design Ideal in front of glazing to prevent cold draughts Available in two depths For high flexibility in usage Historical Kundenedfald Grøn energi Flat

Læs mere

3A Step-Down Voltage Regulator

3A Step-Down Voltage Regulator 3A Step-Down Voltage Regulator DESCRIPITION The series of regulators are monolithic integrated circuits that provide all the active functions for a step-down (buck) switching regulator, capable of driving

Læs mere

ECE 551: Digital System * Design & Synthesis Lecture Set 5

ECE 551: Digital System * Design & Synthesis Lecture Set 5 ECE 551: Digital System * Design & Synthesis Lecture Set 5 5.1: Verilog Behavioral Model for Finite State Machines (FSMs) 5.2: Verilog Simulation I/O and 2001 Standard (In Separate File) 3/4/2003 1 ECE

Læs mere

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1 Project Step 7 Behavioral modeling of a dual ported register set. Copyright 2006 - Joanne DeGroat, ECE, OSU 1 The register set Register set specifications 16 dual ported registers each with 16- bit words

Læs mere

High Voltage AC & DC Film Capacitors

High Voltage AC & DC Film Capacitors RoHS COMPLIANT High Voltage AC & DC Film Capacitors Aerovox high voltage capacitors are constructed with metallized polypropylene film and are available in round or oval aluminum cases with four-blade

Læs mere

Basic statistics for experimental medical researchers

Basic statistics for experimental medical researchers Basic statistics for experimental medical researchers Sample size calculations September 15th 2016 Christian Pipper Department of public health (IFSV) Faculty of Health and Medicinal Science (SUND) E-mail:

Læs mere

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color

Læs mere

RE7RL13BU ZELIO tidsrelæ forsinket frafald - 0,05..1 sek V AC/DC - 2OC

RE7RL13BU ZELIO tidsrelæ forsinket frafald - 0,05..1 sek V AC/DC - 2OC Produkt datablad Karakteristika RE7RL13BU ZELIO tidsrelæ forsinket frafald - 0,05..1 sek. - 24 V AC/DC - 2OC Primær Produktsortiment Zelio Time Produkttype Industrial timing relay Kontaktype og sammensætning

Læs mere

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA TekVor 1300C 1. Before You Begin This guide provides basic guidelines to assist you in quickly getting started. Installation of the transmitter in an explosive environment must be in accordance with the

Læs mere

Plug Connectors for Food & Beverage

Plug Connectors for Food & Beverage Plug Connectors for Food & Beverage Made with stainless steel Food grade quality High protection degree MeeTS DEMANDING HYGIENIC STANDARDS The food and beverage industry needs an extremely clean environment

Læs mere

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret 12-10-2011 /JLK

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret 12-10-2011 /JLK Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings QVEX Clima Revideret 12-10-2011 /JLK mit: JLK CC: Dato: 12-10-2011 Indhoidsfortegnelse I Table

Læs mere

Small Autonomous Devices in civil Engineering. Uses and requirements. By Peter H. Møller Rambøll

Small Autonomous Devices in civil Engineering. Uses and requirements. By Peter H. Møller Rambøll Small Autonomous Devices in civil Engineering Uses and requirements By Peter H. Møller Rambøll BACKGROUND My Background 20+ years within evaluation of condition and renovation of concrete structures Last

Læs mere

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc.

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc. LINK-56K Emulator for Motorola s DSPs A Product of Domain Technologies, Inc. LINK-56K User s Guide, Version1.05 September, 2003 DSPs supported by this product: Motorola DSP56001 Motorola DSP56002 and derivatives

Læs mere

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307346 EN Motion detector LUXA 103-100 U WH 1030040 LUXA 103-100 UA WH 1030045 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing

Læs mere

talk outline sea bed network deployment issues; energy distribution seabed network issues;

talk outline sea bed network deployment issues; energy distribution seabed network issues; talk outline sea bed network deployment issues; energy distribution seabed network issues; data transmission seabed network; seabed network decisional process specification from physics no deployment feasibility

Læs mere

RE7TM11BU ZELIO tidsrelæ forsinket indkobling - 0,05..1 sek V AC/DC - 1OC

RE7TM11BU ZELIO tidsrelæ forsinket indkobling - 0,05..1 sek V AC/DC - 1OC Produkt datablad Karakteristika RE7TM11BU ZELIO tidsrelæ forsinket indkobling - 0,05..1 sek. - 24 V AC/DC - 1OC Primær Produktsortiment Produkttype Type nr. Tidsforsinkelsestype Time delay range Zelio

Læs mere

More Precision. capancdt MD6-22 // Mobile gap gauge

More Precision. capancdt MD6-22 // Mobile gap gauge More Precision capancdt MD6-22 // Mobile gap gauge Capacitive gap gauge capancdt MD6-22 - High-precision gap measurement - Intuitive operation - For electrically conductive measurement objects - Comprehensive

Læs mere

RE7ML11BU ZELIO tidsrelæ forsinket med 6 funktioner - 0,05..1 sek V AC/DC - 1OC

RE7ML11BU ZELIO tidsrelæ forsinket med 6 funktioner - 0,05..1 sek V AC/DC - 1OC Produkt datablad Karakteristika RE7ML11BU ZELIO tidsrelæ forsinket med 6 funktioner - 0,05..1 sek. - 24 V AC/DC - 1OC Primær Produktsortiment Produkttype Type nr. Tidsforsinkelsestype Tidsforsinkelsesområde

Læs mere

Screened electronic cable LiYCY

Screened electronic cable LiYCY Screened electronic cable LiYCY Conductor material: copper, bare Conductor class: class 5 = fine stranded Insulation: PVC Screen: copper braid, tinned Screen coverage: 70 % Sheathing material: PVC Flame-retardant:

Læs mere

USER GUIDE Version 2.9. SATEL Configuration Manager. Setup and configuration program. for SATELLINE radio modem

USER GUIDE Version 2.9. SATEL Configuration Manager. Setup and configuration program. for SATELLINE radio modem USER GUIDE Version 2.9 Setup and configuration program for SATELLINE radio modem 1 TABLE OF CONTENTS 1 TABLE OF CONTENTS... 2 2 GENERAL... 3 2.1 ABOUT SATEL CONFIGURATION MANAGER... 3 3 QUICK GUIDE TO

Læs mere

RE7TP13BU ZELIO tidsrelæ justerbar forsinket indkobling - 0,05..1 sek V AC/DC - 2OC

RE7TP13BU ZELIO tidsrelæ justerbar forsinket indkobling - 0,05..1 sek V AC/DC - 2OC Produkt datablad Karakteristika RE7TP13BU ZELIO tidsrelæ justerbar forsinket indkobling - 0,05..1 sek. - 24 V AC/DC - 2OC Primær Produktsortiment Zelio Time Produkttype Industrial timing relay Kontaktype

Læs mere

STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX. STEP X - Name of Step QUICK START GUIDE LIG1014A, LIG1080A, LIG1082A INDUSTRIAL SWITCH 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Hardware Description LIG1014A LIG1080A TABLE

Læs mere

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Agenda Electromagnetic Compatibility (EMC) Application of Cable Ferrites Impedance

Læs mere

Maskindirektivet og Remote Access. Arbejdstilsynet Dau konference 2015 Arbejdsmiljøfagligt Center Erik Lund Lauridsen

Maskindirektivet og Remote Access. Arbejdstilsynet Dau konference 2015 Arbejdsmiljøfagligt Center Erik Lund Lauridsen Maskindirektivet og Remote Access Arbejdstilsynet Dau konference 2015 Arbejdsmiljøfagligt Center Erik Lund Lauridsen ell@at.dk Marts 2015 1 MD - Personsikkerhed og Remoten Hvad er spillepladen for personsikkerhed

Læs mere

Maneurop reciprocating compressors

Maneurop reciprocating compressors MAKING MODERN LIVING POSSIBLE Maneurop reciprocating compressors MT - MTZ - LTZ - NTZ - 60 z R404A - R507A - R407C - R134a - R22 QUICK REFERENCE PRODUCT RANGE Nominal voltage M-BP Applications LBP Applications

Læs mere

QUICK START Updated:

QUICK START Updated: QUICK START Updated: 24.08.2018 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get started

Læs mere

Proportional pressure regulators VEAA

Proportional pressure regulators VEAA Key features Innovative Versatile Reliable Easy to install Silent operation Very low power consumption High precision Integrated piezo technology In-line valves Sub-base valves Simple electrical and pneumatic

Læs mere

3D NASAL VISTA TEMPORAL

3D NASAL VISTA TEMPORAL USER MANUAL www.nasalsystems.es index index 2 I. System requirements 3 II. Main menu 4 III. Main popup menu 5 IV. Bottom buttons 6-7 V. Other functions/hotkeys 8 2 I. Systems requirements ``Recommended

Læs mere

Elma DT 802D CO2 logger. Dansk/Norsk 2 English 4 EAN:

Elma DT 802D CO2 logger. Dansk/Norsk 2 English 4 EAN: Elma DT 802D CO2 logger Dansk/Norsk 2 English 4 EAN: 5706445840366 Elma DT_802D CO2 logger 2 Brugervejledning Sikkerhed Læs venligst denne brugermanual grundigt igennem og anvend udelukkende instrumentet

Læs mere

User Manual for LTC IGNOU

User Manual for LTC IGNOU User Manual for LTC IGNOU 1 LTC (Leave Travel Concession) Navigation: Portal Launch HCM Application Self Service LTC Self Service 1. LTC Advance/Intimation Navigation: Launch HCM Application Self Service

Læs mere

ELECTRONIC CONTROL BOX 20-0344

ELECTRONIC CONTROL BOX 20-0344 ELECTRONIC CONTROL BOX 20-0344 Specifications Rated voltage: Rated power: Rated current: Pump load: Blower (aux) load: Light load: Heater load: 400V, 50 Hz 11000 W 3 x 16 A Max. 3 x 3000 W Total sum of

Læs mere

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Dansk standard Tillæg DS/IEC 60335-1/A1:2013 + Corr 1:2014 1. udgave 2014-05-08 Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Household and similar electrical appliances

Læs mere

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator Opera Ins Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator I.Precautions 1. Keep the product away from children to avoid children playing it as a toy and resultinginpersonalinjury.

Læs mere

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1 IBM Network Station Manager esuite 1.5 / NSM Integration IBM Network Computer Division tdc - 02/08/99 lotusnsm.prz Page 1 New esuite Settings in NSM The Lotus esuite Workplace administration option is

Læs mere

Switchmode rectifier. Type LEIF with PFC. »We store the world's energy« Network

Switchmode rectifier. Type LEIF with PFC. »We store the world's energy« Network »We store the world's energy« Rectifier / DC-UPS with or without batteries with or without alarm Usage The rectifier is specially designed for charging and maintenance charging of lead acid batteries.

Læs mere

Navn: DVG V 450EC/F400 varenr.: 95257

Navn: DVG V 450EC/F400 varenr.: 95257 DVG-V 450EC/F400 varenr. 95257 Document type: Product card Document date: 2012-11-08 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

Navn: DVG V 560EC/F400 varenr.: 95135

Navn: DVG V 560EC/F400 varenr.: 95135 DVG-V 560EC/F400 varenr. 95135 Document type: Product card Document date: 2012-11-08 Generated by: Systemair online katalog Beskrivelse Brand- og røgventilator 400 C / 120 min Normal ventilation op til

Læs mere

Last Lecture CS Amp. I D V B M 2. I bias. A v. V out. V in. Simplified Schematic. Practical Implementation V GS

Last Lecture CS Amp. I D V B M 2. I bias. A v. V out. V in. Simplified Schematic. Practical Implementation V GS Output Range INEL 565 Analog Circuit Design 1/30/019 Last Lecture CS Amp. I D off ohmic sat sat ohmic ohmic I bias V B I bias V dd V dd -V ov A v Simplified Schematic Practical Implementation V ov1 V th

Læs mere

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that Wilmington Instrument Company, Inc. 332 North Fries Avenue Wilmington,

Læs mere

SecuriFire 2000 & SecuriFire Product presentation.

SecuriFire 2000 & SecuriFire Product presentation. SecuriFire 2000 & SecuriFire 1000. Product presentation. General. Compact system Can be networked SecuriLine extended (2 loops) For controlling single zone extinguishing systems State-of-the-art Multi-Layer

Læs mere

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss Brugervejledning (side 2-6) Userguide (page 7-11) Bedienungsanleitung 1 - Hvordan forbinder du din E-PAD hængelås med din

Læs mere

Aktivering af Survey funktionalitet

Aktivering af Survey funktionalitet Surveys i REDCap REDCap gør det muligt at eksponere ét eller flere instrumenter som et survey (spørgeskema) som derefter kan udfyldes direkte af patienten eller forsøgspersonen over internettet. Dette

Læs mere

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17

SkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17 SkyVision Comfort Installation manual 5.6.02_0517, Comfort, Item no. 2022 Version 05/17 Installation Manual VITRAL SkyVision Comfort Trækarme skal altid opbevares tørt/ Wooden upstands must always be kept

Læs mere

Help / Hjælp

Help / Hjælp Home page Lisa & Petur www.lisapetur.dk Help / Hjælp Help / Hjælp General The purpose of our Homepage is to allow external access to pictures and videos taken/made by the Gunnarsson family. The Association

Læs mere

QUICK START Updated: 18. Febr. 2014

QUICK START Updated: 18. Febr. 2014 QUICK START Updated: 18. Febr. 2014 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get

Læs mere

Diamond Core Drilling

Diamond Core Drilling Diamond Core Drill ZIZ-250Pro Product Description Diamond core drill is a tool used for drilling holes on reinforced concrete, rocks and fire-proof materials. It features in high-efficiency, smooth and

Læs mere

Statistical information form the Danish EPC database - use for the building stock model in Denmark

Statistical information form the Danish EPC database - use for the building stock model in Denmark Statistical information form the Danish EPC database - use for the building stock model in Denmark Kim B. Wittchen Danish Building Research Institute, SBi AALBORG UNIVERSITY Certification of buildings

Læs mere

INSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960!

INSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960! Materials supplied: 1. (10) Zip Ties 2. (4) Hose Clamps 3. (2) Brake Duct Hose 4. (2) Brake Shields 5. (2) Front Brake Ducts ( Stock Fascia Only ) 6. (2) Washers 1 OD ( Stock Fascia Only ) 7. (8) Shims

Læs mere

Date of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO

Date of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO JENSEN CLASSIC FOLDER JENSEN MAX STACKER MANUAL MANUAL Date of issue 2005.11.04 Fremstillingsdato Machine no. 760790, 492147 Maskinnr. Distributor / Forhandler Project Manufacturer / Fabrikant JENSEN USA

Læs mere

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001 Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001 Ls venligst denne instruktions manual igennem inden brug af produktet Thank you for purchasing our product. This smart unit is not

Læs mere

LED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit. www.osram.com 1. HOW CAN I UNDERSTAND THE FOLLOWING SHEETS?

LED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit. www.osram.com 1. HOW CAN I UNDERSTAND THE FOLLOWING SHEETS? BASIC INFORMATION: 1. HOW CAN I UNDERSTAND THE FOLLOWING SHES? Compatibility to OSRAM s: -Series Circuit... Page 2 -Parallel Circuit... Page 3 Compatibility to OTHER s : -Series Circuit... Page 4 -Parallel

Læs mere

3D NASAL VISTA 2.0

3D NASAL VISTA 2.0 USER MANUAL www.nasalsystems.es index index 2 I. System requirements 3 II. Main menu 4 III. Main popup menu 5 IV. Bottom buttons 6-7 V. Other functions/hotkeys 8 2 I. Systems requirements ``Recommended

Læs mere

Datamate L-Tek Specification. Pin Numbering DATAMATE L-TEK. Materials. Mechanical. Electrical. Environmental. 5 Female. Female. Male.

Datamate L-Tek Specification. Pin Numbering DATAMATE L-TEK. Materials. Mechanical. Electrical. Environmental. 5 Female. Female. Male. Datamate L-Tek Specification Materials Mouldings: Female contacts: Male contacts: Finish: Electrical Glass-filled thermoplastic UL94V-0 rass shell, with eryllium Copper inner contact Copper alloy See individual

Læs mere

Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt

Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt Passage 1 Passage 2 Passage 3 Passage 4 Passage 5 27 Bilag 2 Engelsk beskrivelse af S4-måleren InterOcean S4 Current Meter The S4 Electromagnetic

Læs mere

Clear aim to ensure safety of all people involved in optical links project Scope

Clear aim to ensure safety of all people involved in optical links project Scope Laser Safety Outline Clear aim to ensure safety of all people involved in optical links project Scope Hazard classification of CMS Tracker readout link system Requirements Note: Safety requirements here

Læs mere

MultiProgrammer Manual

MultiProgrammer Manual MultiProgrammer Manual MultiProgrammeren bruges til at læse og skrive værdier til ModBus register i LS Controls frekvensomformer E 1045. Dansk Version side 2 til 4 The MultiProgrammer is used for the writing

Læs mere

Family of R744 control valves and suggestions for efficient testing

Family of R744 control valves and suggestions for efficient testing Family of R744 control valves and suggestions for efficient testing Norbert Stulgies, Axel Müller, Horst Kappler, Timo Greeb, Wilhelm Tegethoff, Sven Försterling, Jürgen Köhler 1 Contents 1. Motivation

Læs mere

Lovkrav vs. udvikling af sundhedsapps

Lovkrav vs. udvikling af sundhedsapps Lovkrav vs. udvikling af sundhedsapps Health apps give patients better control User Data Social media Pharma Products User behaviour Relatives www Self monitoring (app) data extract Healthcare specialists

Læs mere

PARATHOM / PARATHOM PRO MR16 Electric Transformer Compatibility

PARATHOM / PARATHOM PRO MR16 Electric Transformer Compatibility / PRO MR16 Electric Transformer Compatibility BASIC INFORMATION: 1. HOW CAN I UNDERSTAND THE FOLLOWING SHES? Compatibility to OSRAM s: -Series Circuit... Page 2 -Parallel Circuit... Page 3 Compatibility

Læs mere

ELECTRONIC CONTROL BOX 20-0313

ELECTRONIC CONTROL BOX 20-0313 ELECTRONIC CONTROL BOX 20-0313 Specifications Rated voltage: Rated power: Rated current: Output A: Output B: Output C: 230VAC, 50Hz, single phase 2300W 10 A Max. 900W The total sum of the loads must not

Læs mere

Skidding System. Challenge Us

Skidding System. Challenge Us Skidding System n Malm Orstads cutting edge Engineering department designs and fabricates tailor made skidding systems for all kinds of enviroments. Our skidding systems are amongst the most efficient

Læs mere

Dynamic Voltage and Frequency Management Based on Variable Update Intervals

Dynamic Voltage and Frequency Management Based on Variable Update Intervals Dynamic Voltage and Frequency Management Based on Variable Update Intervals for Frequency Setting Mehrdad Najibi Mostafa Salehi Ali Afzali Kusha Massoud Pedram S. Mehdi Fakhraie Hossein Pedram Presentation

Læs mere

515.[[ [[$6(5,(6 [[$[[ [[%[[ SOT-23-5 VFM STEP-UP DC/DC CONVERTER

515.[[ [[$6(5,(6 [[$[[ [[%[[ SOT-23-5 VFM STEP-UP DC/DC CONVERTER SOT-3- VFM STEP-UP DC/DC CONVERTER.[[ [[$[[ [[%[[ [[$6(,(6 NO. EA-- OUTLINE 7KH.[[$[[%[[$ 6HULHV DUH &6EDVHG 9) &KRSSHU 6WHSXS '&'& FRQYHUWHU,&V ZLWK XOWUD ORZVXSSO\FXUUHQWDQGKLJKRXWSXWYROWDJHDFFXUDF\

Læs mere

Komplet køreklar 6000 W Solcelle anlæg. Kr. 122.400,- inkl. moms

Komplet køreklar 6000 W Solcelle anlæg. Kr. 122.400,- inkl. moms Indeholder komplet system: Komplet køreklar 6000 W Solcelle anlæg Kr. 122.400,- inkl. moms 24 stk 250 W Monocrystalinske Full Black Solpaneler (ca.41m 2 ) 2 stk Dansk godkendte 3000 W Invertere med 10

Læs mere

OVERVIEW MARINE HYBRID ÜBERSICHT SCHEMA MARINE HYBRID

OVERVIEW MARINE HYBRID ÜBERSICHT SCHEMA MARINE HYBRID OVERVIEW MARINE HYBRID ÜBERSICHT SCHEMA MARINE HYBRID Electromechanic Power Unit STEYR MARINE DIESEL STARTER BATTERY ROTOR VDC RAW WATER SUPPLY 77/ -tedoc ELECTRIC INSTALLATION SCHEMATIC - HYBRID SCC -

Læs mere

Komplet køreklar 3000 W Solcelle anlæg. Kr. 71.400,- inkl. moms

Komplet køreklar 3000 W Solcelle anlæg. Kr. 71.400,- inkl. moms Indeholder komplet system: Komplet køreklar 3000 W Solcelle anlæg Kr. 71.400,- inkl. moms 12 stk 250 W Monocrystalinske Full Black Solpaneler (ca.20m 2 ) 1 stk Dansk godkendt 3000 W Inverter Diskret Full

Læs mere

SP40G001 40GKX GMC. Split system "Global Cassette" indoor unit. Spare parts 40GKX GKX

SP40G001 40GKX GMC. Split system Global Cassette indoor unit. Spare parts 40GKX GKX SP0G00 0GKX GMC Split system "Global Cassette" indoor unit Spare parts 0GKX 0-08-0 0GKX 08-08-05-060 0GKX 0-08-0 Split system "Global Cassette" indoor unit (Without electric heater) 8 7 9 6 5 0 5 6 7 8

Læs mere

PMDK PC-Side Basic Function Reference (Version 1.0)

PMDK PC-Side Basic Function Reference (Version 1.0) PMDK PC-Side Basic Function Reference (Version 1.0) http://www.icpdas.com PMDK PC-Side Basic Function Reference V 1.0 1 Warranty All products manufactured by ICPDAS Inc. are warranted against defective

Læs mere