Palm Size Multimeter
|
|
- Edith Ravn
- 4 år siden
- Visninger:
Transkript
1 Palm Size Multimeter User Manual Part Number: , and Page <1> 04/03/19 V1.0
2 1. Overview The new generation series products redefine the performance standards for entry-level digital multimeter. The innovative industrial design ensures the products have 2 meters impact resistance. The new LCD display layout provides a clear display for better user experience. The series ensure safe operation in CAT II 250 V environment. The special features of each model are as follows: : 2mF capacitance test function : Temperature test : NCV test 2. Open Box Inspection Open the package box and take out the device. Please check whether the following items are deficient or damaged and contact your supplier immediately if they are. User Manual Test Leads Protective case K-type thermocouple Warning: 1 Pcs 1 Pair 1 Pcs 1 Pcs ( only) Please carefully read Safe Operation Rule before using the device. 3. Safe Operation Rule 1) Safety certification This device strictly follows the CE standards: EN : 2010, EN : 2010, EN 61326: 2013, as well as CAT II: 250V, RoHS, pollution grade ll, and double insulation standards. 2) Safety instructions and precautions a. Do not use the device if the device or test leads appear damaged or if you suspect that the device is not operating property. Pay particular attention to the insulation layers. b. If the test leads are damaged, it must be replaced with one of the same type or the same electrical specification. c. When measuring, do not touch exposed wires, connectors, unused inputs, or the circuit being measured. d. When measuring the voltage higher than 60V DC or 30V ACrms, keep your fingers behind the finger guard on the test lead in order to prevent electric shock. e. If the range of the voltage to be measured is unknown, the maximum range should be selected and then gradually decreased. f. Never input voltage and current exceeding the value listed on the device. g. Before switching ranges, make sure to disconnect the test leads with the circuit to be tested. It is strictly prohibited to switch the ranges during the measurement. h. Do not use or store the device in high temperature, high humidity, flammable, explosive or strong magnetic field environments. i. Do not change the internal circuit of the device in order to avoid the damage to the device and users. j. To avoid false reading, replace the battery when the battery indicator appears. k. Use dry cloth to clean the case, do not use detergent containing solvents Page <2> 04/03/19 V1.0
3 4. Electrical Symbols CAT II Low battery Electrical ground Warning Double insulation High Voltage warning Direct current Alternating current Conforms to UL STD , , Certified to CSA STD. C22.2 No , Comply with European Union Standards It is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the low-voltage MAINS installation. 5. Specification 1. The maximum voltage between the input terminal and the ground: 250Vrms 2. 10A terminal: Fuse 10A 250V Fast fuse Ø5 20mm 3. ma/μa terminal: Fuse 200mA 250V Fast fuse Ø5 20mm 4. Max. display 1999, over range display OL, update rate: 2~3 times/second 5. Range select: Auto range ; Manual range /435/ Backlight: manual on, auto shut off after 30 seconds. 7. Polarity: - symbol displayin on screen represents negative polarity signal. 8. Data hold function: symbol displays on screen when data hold function is activated. 9. Low battery power: symbol displays on screen when battery power is low 10. Battery: AAA 1.5V Operating temperature: 0 ~ 40 C (32 F ~ 104 F) Storage temperature: -10 C ~ 50 C (14 F ~ 122 F) Relative humidity: 0 C ~ 30 C: %75% RH, 30 C to 40 C: %50% RH Operating altitude: 0 ~ 2000m 12. Dimension: (134mm 77mm 47mm) 13. Weight: about 206g (battery included) 14. Electromagnetic compatibility: In fields with less the 1V/m radio frequency, the total accuracy = designated accuracy +5% of measurement range In fields with more than 1V/m radio frequency, the accuracy is not specified. 6. Structure 1. Display screen 2. Function keys 3. Functional dial 4. 10A input jack 5. COM jack 6. Remaining inputs jack (See Figure 1) Page <3> 04/03/19 V1.0
4 7. Key Functions 1) : SEL/REL: press this key to switch between AC and DC modes for mv, I and REL positions. HOLD/ : Press to enter or exit data hold mode. Long press over 2 seconds to turn on/off backlight. 2) /435/440: HOLD/SEL: Press to enter or exit data hold mode In continuity/diode mode, press to cycle switch between the two modes : Press to turn on/off backlight. 8. Operations To avoid false reading, replace the battery if the battery low power symbol appears. Also pay special attention to the warning sign beside the test lead jack, indication that the tested voltage or current must not exceed the values listed on device. 1. AC/DC voltage measurement (see Figure 2b) 1) Switch the dial to V~ position. 2) Insert the black test lead into the COM jack, the red test lead into the VΩmA jack. Connect test leads with the load in parallel /435/440: Notes: Do not measure voltage over 250Vrms, or it may expose users to electric shock and damage the device. If the range of the voltage to be measured is unknown, select the maximum range and reduce accordingly. Please pay extra attention when measuring high voltage in order to avoid electric shock. Before using the device, it is suggested to measure a known voltage for verification. 2. Resistance measurement (see Figure 2b) 1) Switch the dial to Ω position. 2) Insert the black test lead into the COM jack, the red test lead into the VΩmA jack. Connect test leads with the resistor in parallel Page <4> 04/03/19 V1.0
5 Notes: Before measuring resistance, switch off the power supply of the circuit, and fully discharge of capacitors. If the resistance when probes are shorted is more than 0.5Ω, please check if test leads are loosened or damaged. If the resistor is open or over the range, the OL symbol will be displayed on the screen. When measuring low resistance, the test leads will produce 0.1Ω ~ 0.2Ω measurement error. To obtain accurate measurement, the measured value should subtract the value displayed when two test leads are shorted. When measuring high resistance above 1MΩ, it is normal to take a few seconds to steady the readings. In order to quickly obtain steady data, use short test wires to measure high resistance. 3. Continuity measurement (see Figure 2b) 1) Switch the dial to position. 2) Insert the black test lead into the COM jack, the red test lead into the VΩmA jack. Connect test leads with the points to be tested in parallel 3) If measured points resistance >51Ω, circuit is in open status. If measured points resistance 10Ω, circuit is in good conduction status, buzzer will go off Note: Before measuring continuity, switch off all power supplies and fully discharge all capacitors. 4. Diode measurement (see Figure 2b) 1) Switch the dial to position. 2) Insert the black test lead into the COM jack, the red test lead into the VΩmA jack. Connect test leads with the diode in parallel 3) OL symbol appears when the diode is open or polarity is reversed. For silicon PN junction, normal value: 500 ~ 800mV (0.5 ~ 0.8V). Note: Before measuring PN junction, switch off the power supply to the circuit, and fully discharge all capacitors 5. Capacitance measurement (only for , see Figure 2a) 1) Switch the dial to capacitance test. 2) Insert the black test lead into the COM jack, the red test lead into the VΩmA jack. Connect test leads with the capacitor in parallel 3) When there is no input, the device displays a fixed value (intrinsic capacitance). For small capacitance measurement, to ensure measurement accuracy, the measured value must be subtracted from intrinsic capacitance. Users can measure small capacity capacitors with relative measurement functions (REL) (the device will automatically subtract the intrinsic capacitance) Notes: If the tested capacitor is shorted or its capacity is over the specified range OL symbol will be displayed on the screen. When measuring large capacitors, it may take a few seconds to obtain steady readings Before measuring capacitors (especially for high voltage capacitors), please fully discharge them. 6. DC measurement (see Figure 3) 1) Switch the dial to DC test. 2) Insert the black test lead into the COM jack, the red test lead into the VΩmA jack. Connect test leads with the tested circuit in series. Page <5> 04/03/19 V1.0
6 Notes: Before measuring, switch of the power supply of the circuit and carefully check the input terminal and range position. If the range of the measured current is unknown, select the maximum range and then reduce accordingly. Please replace the fuse with the same type. 10A jack: Fuse 10A/250V Ø5mm 20mm VΩmA jack: Fuse 0.2A/250V Ø5mm 20mm When measuring, please do not connect the test leads with any circuit in parallel. Otherwise there is a risk of damage to the device and human body. If the tested current is over 10A, each measurement time should be less than 10 seconds and the next test should be after 15 minutes. 7. AC measurement (only for , see Figure 3) Similar to DC Measurement. Please refer to Section 6 DC measurement (see Figure 3) 8. Temperature measurement (only for , see Figure 5) 1) Switch the dial to temperature test. 2) Insert K-thermocouple into the device and fix the temperature probe to the measured object. Read the value when it is stable. Notes: Only K-thermocouple is applicable. The measured temperature should be less than 250 C/482 F ( F= C ) Page <6> 04/03/19 V1.0
7 10. NCV measurement (only for , see Figure 6) 1) Switch the dial to NCV position 2) Place the device near the measured object. - symbol indicates the intensity of the electric field. More - and the higher the buzzer frequency, the higher the electric field intensity. 3) Intensity of electric field. EF : 0 ~ 50mV - : 50 ~ 100mV -- : 100 ~ 150mV --- : 150 ~ 200mV ---- : >200mV 11. Additional features The device enters measurement status in 2 seconds after startup. The device automatically shuts down if there is no operation for 15 minutes. you can wake up the device by pressing any key. To disable auto shutdown, switch the dial to OFF position, long press HOLD key and turn on the device. When pressing any key or switching the dial, the buzzer will beep once. Buzzer Notification 1) Input voltage ^250V (AC/DC), buzzer will continuously beep indicating measure range is at limit 2) Input current >10A (AC/DC), buzzer will continuously beep indicating measure range is at limit 1 min before auto shutdown, 5 continuous beeps. Before shutdown, 1 long beeps. Low power warnings: Voltage of the battery <2.5V, symbol appears and flashes for 3 seconds every 6 second period. During low power status, the device can still work. Voltage of the battery <2.2V, a solid symbol appears, the device cannot work. 9. Technical specification Accuracy: ±(% of reading + numerical value in least significant digit slot) 1 year warranty Page <7> 04/03/19 V1.0
8 Ambient Temperature: 23 C ±5 C (73.4 F ±9 F) Ambient humidity: %75% RH Notes To ensure accuracy, operating temperature should be within 18 C ~ 28 C. Temperature Coefficient = 0.1*(Specified accuracy)/ C (<18 C or >28 C) 1. DC Voltage Range Part Number Resolution Accuracy 200mV 0.1mV ±(0.7% +3) 2000mV 1mV ±(0.5% +2) 20.00V /13435/ V ±(0.7% +3) 200.0V 0.1V ±(0.7% +3) 250V 1V ±(0.7% +3) Input impedance: about 10MΩ Results might be unstable at mv range when no load is connected. The value becomes stable once the load is connected. Least significant digit %±3 Max. input voltage: ±250V, when the voltage^ 610V, OL symbol appears. 2. AC Voltage Range Part Number Resolution Accuracy 200mV 0.1mV ±(1% +2) 2V V ±(0.7% +3) 20V 0.01V ±(1% +2) 200V 0.1V ±(1.2% +3) /13435/ V 1V ±(1.2% +3) Input impedance: about 10MΩ Frequency response: 40Hz ~ 400Hz, sine wave RMS (average response). Max. input voltage: ±250V, when the voltage 610V, OL symbol appears. 3. Resistance Range Part Number Resolution Accuracy 200Ω 0.1Ω ±(1% +2) 2000Ω 1Ω ±(0.8% +2) 20kΩ /13435/ kΩ ±(0.8% +2) 200kΩ 0.1kΩ ±(0.8% +2) 20mΩ 0.01MΩ ±(1.2% +3) 200mΩ / MΩ ±(5% +10) Page <8> 04/03/19 V1.0
9 Measurement result = reading of resistor - reading of shorted test leads 4. Continuity, diode Range Resolution Remark 0.1Ω 0.001V If the measured resistance is greater than 50Ω, the measured circuit will be regarded as in open status, and the buzzer does not go off. If the measured resistance is less than 10Ω, the measured circuit will be regarded as in good conduction status, and the buzzer goes off. Open circuit voltage: 2.1V, test current is about 1mA Silicon PN junction voltage is about 0.5 ~ 0.8V 5. Capacitance (only for ) Range Resolution Accuracy 2nF 0.001nF Under REL mode ±(5% +5) 20nF 0.01nF ±(4% +8) 200nF 0.1nF ±(4% +8) 2μF 0.001μF ±(4% +8) 20μF 0.01μF ±(4% +8) 200μF 0.1μF ±(4% +8) 2mF 0.001mF ±(10) Tested capacitance %200nF, adapt REL mode. 6. Temperature (only for ) Range Resolution Accuracy -40 ~ 40 C ±4 C C -40 C ~ 1000 C >40 C ~ 500 C 1 C ±(1% +4) >500 C ~ 1000 C ±(2% +4) -40 F ~ 104 F ±5 F F -40 F ~ 1832 F >104 F ~ 932 F 1 F ±(1.5% +5) >932 F ~ 1832 F ±(2.5% +5) K thermocouple is only applicable for temperature less than 250 C/482 F. Page <9> 04/03/19 V1.0
10 7. DC current Range Part Number Resolution Accuracy 200μA μA ±(1% +2) 2000μA /13435/ μA ±(1% +2) 20mA /13435/ mA ±(1% +2) 200mA /13435/ mA ±(1% +2) 2A A ±(1.2% +5) 10A /13435/ A ±(1.2% +5) Input current> 10A, OL symbol appears and buzzer beeps Overload protection 250Vrms μa ma range: F1 Fuse 0.2A/250V Ø5 20mm 10A range: F2 Fuse 10A/250V Ø5 20mm 8. AC current (only for ) Range Part Number Resolution Accuracy 200μA 0.1μA ±(1.2% +3) 2000μA 1μA ±(1.2% +3) 20mA 0.01mA ±(1.2% +3) mA 0.1mA ±(1.2% +3) 2A 0.001A ±(1.5% +5) 10A 0.01A ±(1.5% +5) Frequency response: Hz Accuracy guarantee range: 5-100% of the range, shorted circuit allows least significant digit %2 Input current >10.1A, OL symbol appears with beeps Overload protection 250Vrms μa ma range: F1 Fuse 0.2A/250V Ø5 20mm 10A range: F2 Fuse 10A/250V Ø5 20mm 10. Maintenance Warning: Before opening the rear cover, switch of the power supply (remove test leads from the input terminal and the circuit). 1. General maintenance 1) Clean the case with a damp cloth and detergent. Do not use abradants or solvents 2) If there is any malfunction, stop using the device and send it to maintenance. 3) The maintenance and service must be conducted by qualified professionals or designated departments. 2. Replacements (see Figure 7a, Figure 7b) Battery replacement: To avoid false reading, replace the battery when the battery indicator appears. Battery specification: AAA 1.5V 2 1) Switch the dial to OFF position and remove the test leads from the input terminal. Page <10> 04/03/19 V1.0
11 2) Take off the protective case. Loosen the screw on battery cover, remove the cover to replace the battery. Please identify the positive and negative pole. Fuse replacement: 1) Switch the dial to OFF position and remove the test leads from the input terminal 2) Loosen the both screws on the rear cover, then remove the rear cover to replace the fuse Fuse specification F1 Fuse 0.2A/250V Ø5 20mm ceramic tube F2 Fuse 10A/250V Ø5 20mm ceramic tube Important Notice : This data sheet and its contents (the Information ) belong to the members of the Premier Farnell group of companies (the Group ) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group s liability for death or personal injury resulting from its negligence. Tenma is the registered trademark of the Group. Premier Farnell Limited Page <11> 04/03/19 V1.0
UNISONIC TECHNOLOGIES CO.,
UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output
Læs mereWIO200A Water in oil sensor
WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic
Læs mereMS-H280-Pro Magnetic Stirrer
MS-H280-Pro Magnetic Stirrer www..com Copyright: No part of this manual may be reproduced or transmitted without prior written permission of. VERSION201407 CONTENTS Chapter 1: Working Principle... 3 1
Læs mereME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package
High Speed LDO Regulators, High PSRR, Low noise, Series General Description The series are highly accurate, low noise, CMOS LDO Voltage Regulators. Offering low output noise, high ripple rejection ratio,
Læs mereElma DT 802D CO2 logger. Dansk/Norsk 2 English 4 EAN:
Elma DT 802D CO2 logger Dansk/Norsk 2 English 4 EAN: 5706445840366 Elma DT_802D CO2 logger 2 Brugervejledning Sikkerhed Læs venligst denne brugermanual grundigt igennem og anvend udelukkende instrumentet
Læs mereDANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!
DANSK INSTALLATIONSVEJLEDNING VLMT500 Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse. Kontroller at
Læs mereframe bracket Ford & Dodge
, Rev 3 02/19 frame bracket 8552005 Ford & Dodge ITEM PART # QTY DESCRIPTION 1 00083 8 NUT,.50NC HEX 2 00084 8 WASHER,.50 LOCK 3 14189-76 2 FRAME BRACKET 4 14194-76 1 411AL FRAME BRACKET PASSENGER SIDE
Læs mereDigital/Analog Megohmmeter Model 1026
Digital/Analog Megohmmeter Model 1026 USER MANUAL MEGOHMMETER MODEL 1026 MΩ V Ω TEST LOCK HOLD 4000Ω MΩ - 250V MΩ - 500V V MΩ - 1000V OFF MΩ V Ω 600V CAT III 1000V CAT II 1000V Statement of Compliance
Læs mereTM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax
TM4 Central Station User Manual / brugervejledning K2070-EU STT Condigi A/S Niels Bohrs Vej 42, Stilling 8660 Skanderborg Denmark Tel. +45 87 93 50 00 Fax. +45 87 93 50 10 info@sttcondigi.com www.sttcondigi.com
Læs mereDavo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8
Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8 DK: Davo-Meg 1002: 87 98 301 819 Davo-Meg 1002B: 87 98 301 822 EAN: Davo-Meg 1002: 5703534100059 Davo-Meg 1002B: 5703534100202 Indhold
Læs mereSikkerhedsvejledning
11-01-2018 2 Sikkerhedsvejledning VIGTIGT! Venligst læs disse instruktioner inden sengen samles og tages i brug Tjek at alle dele og komponenter er til stede som angivet i vejledningen Fjern alle beslagsdele
Læs mereBRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400
BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400 BETJENINGSVEJLEDNING 1. Vigtigt: Før du tilslutter spændingstransformerne til stikkontakten i dit hjem, skal du sørge
Læs mereOpera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator
Opera Ins Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator I.Precautions 1. Keep the product away from children to avoid children playing it as a toy and resultinginpersonalinjury.
Læs mereTDC 4 Indoor voltage transformers
Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,
Læs merePortal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration
Portal Registration Step 1 Provide the necessary information to create your user. Note: First Name, Last Name and Email have to match exactly to your profile in the Membership system. Step 2 Click on the
Læs mereMetal Oxide Varistor:TVM-B Series
Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction
Læs merePrivat-, statslig- eller regional institution m.v. Andet Added Bekaempelsesudfoerende: string No Label: Bekæmpelsesudførende
Changes for Rottedatabasen Web Service The coming version of Rottedatabasen Web Service will have several changes some of them breaking for the exposed methods. These changes and the business logic behind
Læs mereProject Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1
Project Step 7 Behavioral modeling of a dual ported register set. Copyright 2006 - Joanne DeGroat, ECE, OSU 1 The register set Register set specifications 16 dual ported registers each with 16- bit words
Læs mereBilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).
Bilag 8. TDC technical requirements for approval of splitters and inline s intended for shared access (ADSL or VDSL over POTS). Dette bilag udgør bilag 8 til det mellem parterne tiltrådte Produkttillæg
Læs mereDANSK. INSTALLATIONSVEJLEDNING DS Pro Lærred med motor ADVARSEL!
DANSK INSTALLATIONSVEJLEDNING DS Pro Lærred med motor Udpakningsinstruktioner Åben indpakningen forsigtigt og læg indholdet på et stykke pap eller en anden beskyttende overflade for at undgå beskadigelse.
Læs mereBrugsanvisning. Installation Manual
Manual size: 148 x 210 mm 175g copper paper(铜版纸印刷) UNIVERSAL BIL TAGBAGAGEBÆRER Brugsanvisning UNIVERSAL CAR ROOF RACK Installation Manual Model no. 10889 Tak fordi du valgte dette produkt, som vi håber
Læs mereWIO200A INSTALLATIONS MANUAL Rev Dato:
WIO200A INSTALLATIONS MANUAL 111686-903 Rev. 1.01 Dato: 10.01.2013 Side 1 af 14 Contents Contents... 2 Introduction... 3 Pin assignment of the terminal box connector for customer... 4 Pin assignment of
Læs mereXXL-Rehab 4-punkt Stok XXL-Rehab 4-point Cane
XXL-Rehab 4-punkt Stok XXL-Rehab 4-point Cane Anvendelse Use Max 270 kg Brugsanvisning User manual DK Kan med fordel anvendes til: - Bariatriske brugere. UK Ideal use for: - Bariatric users. Brugsanvisning
Læs mereQUICK START Updated:
QUICK START Updated: 24.08.2018 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get started
Læs mereRPW This app is optimized for: For a full list of compatible phones please visit radiation. result.
TM TM RPW-1000 Laser Distance Measurer This app is optimized for: For a full list of compatible phones please visit www.ryobitools.eu/phoneworks IMPORTANT SAFETY S READ AND UNDERSTAND ALL INSTRUCTIONS.
Læs mereQUICK START Updated: 18. Febr. 2014
QUICK START Updated: 18. Febr. 2014 For at komme hurtigt og godt igang med dine nye Webstech produkter, anbefales at du downloader den senest opdaterede QuickStart fra vores hjemmeside: In order to get
Læs mereLED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit. www.osram.com 1. HOW CAN I UNDERSTAND THE FOLLOWING SHEETS?
BASIC INFORMATION: 1. HOW CAN I UNDERSTAND THE FOLLOWING SHES? Compatibility to OSRAM s: -Series Circuit... Page 2 -Parallel Circuit... Page 3 Compatibility to OTHER s : -Series Circuit... Page 4 -Parallel
Læs mereLithium-Ion Jump-Starters / Jumper Cables
AUTOMOTIVE Lithium-Ion Jump-Starters / Jumper Cables Lithium-Ion Jump-Starter 1300: Part No. DRLJS130 1300 4 6 8 cylinder (6 liter gas 3 liter diesel) SafeJump technology prevents sparking and protects
Læs mereXXL-Rehab Stok XXL-Rehab Walking Cane
XXL-Rehab Stok XXL-Rehab Walking Cane Anvendelse Use Max 270 kg Brugsanvisning User manual DK Bruges til: - Bariatriske brugere. UK For use by: - Bariatric users. Brugsanvisning for XXL-Rehab Stok ADVARSEL
Læs mereBasic statistics for experimental medical researchers
Basic statistics for experimental medical researchers Sample size calculations September 15th 2016 Christian Pipper Department of public health (IFSV) Faculty of Health and Medicinal Science (SUND) E-mail:
Læs mereE-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss
E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss Brugervejledning (side 2-6) Userguide (page 7-11) Bedienungsanleitung 1 - Hvordan forbinder du din E-PAD hængelås med din
Læs mereRecall information fra C. Reinhardt
Ballerup, den 19. januar 2016 Recall information fra C. Reinhardt Kære alle Vi har modtaget en recall fra Suzuki Global. I dette brev kan du læse de vigtigste punkter vedrørende problemerne og hvordan
Læs mere1. Basic safety information 3 2. Proper use 3
307346 EN Motion detector LUXA 103-100 U WH 1030040 LUXA 103-100 UA WH 1030045 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing
Læs mereAFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf
JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color
Læs mereDIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS
DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen
Læs mereConstant Terminal Voltage. Industry Workshop 1 st November 2013
Constant Terminal Voltage Industry Workshop 1 st November 2013 Covering; Reactive Power & Voltage Requirements for Synchronous Generators and how the requirements are delivered Other countries - A different
Læs mereVores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov.
På dansk/in Danish: Aarhus d. 10. januar 2013/ the 10 th of January 2013 Kære alle Chefer i MUS-regi! Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov. Og
Læs mereXXL-Rehab 4-punkt Stok XXL-Rehab 4-point Cane
XXL-Rehab 4-punkt Stok XXL-Rehab 4-point Cane Anvendelse Use Max 270 kg Brugsanvisning User manual DK Bruges til: - Bariatriske brugere. UK For use by: - Bariatric users. Brugsanvisning for XXL-Rehab 4-punkt
Læs mereINSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960!
Materials supplied: 1. (10) Zip Ties 2. (4) Hose Clamps 3. (2) Brake Duct Hose 4. (2) Brake Shields 5. (2) Front Brake Ducts ( Stock Fascia Only ) 6. (2) Washers 1 OD ( Stock Fascia Only ) 7. (8) Shims
Læs mereDIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).
DIVAR VIGTIGT! / IMPORTANT! VIGTIGT læs vores anvisninger før du bruger produktet. Har du problemer med den elektriske installation, skal du kontakte en elektriker. Sørg for at altid slukke for strømmen
Læs mereQuick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA
TekVor 1300C 1. Before You Begin This guide provides basic guidelines to assist you in quickly getting started. Installation of the transmitter in an explosive environment must be in accordance with the
Læs mereBilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt
Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt Passage 1 Passage 2 Passage 3 Passage 4 Passage 5 27 Bilag 2 Engelsk beskrivelse af S4-måleren InterOcean S4 Current Meter The S4 Electromagnetic
Læs mereR9H R9H R9H R9H R9H R9H R9H13303
Resi9 en da R9H84 - R9H84 - R9H84 - R9H844 - R9H0 - R9H0 - R9H0 IP0 NVE5695 http://tv.schneider-electric.com This service guide must be kept for future use. PLEASE NOTE bbthis equipment should be installed,
Læs mereUser Manual for LTC IGNOU
User Manual for LTC IGNOU 1 LTC (Leave Travel Concession) Navigation: Portal Launch HCM Application Self Service LTC Self Service 1. LTC Advance/Intimation Navigation: Launch HCM Application Self Service
Læs mere4000 Generation Vejeceller Single Point Vejecelle SPSXL. Applikationer. Unikke Fordele
4000 Generation Vejeceller Single Point Vejecelle SPSXL Unikke Fordele Udviklet og produceret i Danmark Fremstillet i rustfrit stål 1.4542 (17-4 PH) Robust kapacitiv teknologi Høj overlast tolerance (op
Læs mereTechnical Specifications
Technical Specifications Pressure measuring range (bar) 0.1... 0.5, (1) > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar > 200 bar Accuracy, (5), (± % FS)
Læs merePlug Connectors for Food & Beverage
Plug Connectors for Food & Beverage Made with stainless steel Food grade quality High protection degree MeeTS DEMANDING HYGIENIC STANDARDS The food and beverage industry needs an extremely clean environment
Læs mereDigital Clamp Meter. Instruction Manual DT-9250
Digital Clamp Meter Instruction Manual DT-9250 Malmbergs Elektriska AB, PO Box 144, SE-692 23 Kumla, SWEDEN Phone: +46 (0)19-58 77 00 Fax: +46 (0)19-57 11 77 info@malmbergs.com www.malmbergs.com Contents
Læs mereUnitel EDI MT940 June 2010. Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)
Unitel EDI MT940 June 2010 Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004) Contents 1. Introduction...3 2. General...3 3. Description of the MT940 message...3 3.1.
Læs mereELECTRONIC CONTROL BOX 20-0344
ELECTRONIC CONTROL BOX 20-0344 Specifications Rated voltage: Rated power: Rated current: Pump load: Blower (aux) load: Light load: Heater load: 400V, 50 Hz 11000 W 3 x 16 A Max. 3 x 3000 W Total sum of
Læs mereSkyVision Comfort Installation manual _0517, Comfort, Item no Version 05/17
SkyVision Comfort Installation manual 5.6.02_0517, Comfort, Item no. 2022 Version 05/17 Installation Manual VITRAL SkyVision Comfort Trækarme skal altid opbevares tørt/ Wooden upstands must always be kept
Læs mereSOT-363 Plastic-Encapsulate Transistors
JIANGSU CHANGJING ELECTRONICS TECHNOLOGY CO., LTD SOT-363 Plastic-Encapsulate Transistors UMZ2N DUAL TRANSISTOR (PNP+NPN) FEATURES Both 2SA37AK and 2SC242K chip in a package Transistor elements are independent,
Læs mereWATER BATH I Instruction Manual. Water Bath. Digital Control. Cat. No
Water Bath Digital Control Cat. No 340120 General Information 1. Unpack with care Please contact our sales office if any items are missing. 2. Read this instruction manual before start up. 3. For any question
Læs mereH07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:
Industrial flexible rubber cable range with an insulation and sheath in elastomers. Cables for heavy duty uses, Oil resistant and Flame retardancy according to IEC/EN 60332-1-2 standard. BESKRIVELSE Application
Læs mereMandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.
Mandara 1,884 sq. ft. Tradition Series Exterior Design A Exterior Design B Exterior Design C Exterior Design D 623.935.6700 robson.com Tradition OPTIONS Series Exterior Design A w/opt. Golf Cart Garage
Læs mereVarenr.: 553925 90 højre 553926 90 venstre 554027 90º højre med coating 554028 90º venstre med coating
DK GH Skiftespor Varenr.: 55395 90 højre 55396 90 venstre 55407 90º højre med coating 55408 90º venstre med coating 553991 60º højre 553995 60º venstre 551058 60º højre med coating 551059 60º venstre med
Læs mereDANSK / ENGLISH DS PRO PROJEKTORBESLAG 180 CM MANUAL DS PRO PROJECTOR BRACKET 180 CM OWNERS MANUAL
DANSK / ENGLISH DANSK SIDE 1 DS Pro PRO projektorbeslag PROJEKTORBESLAG 180 cm 180 CM Tillykke med dit nye DS Pro projektorbeslag 180 cm. For at opnå det bedste resultat bedes du læse denne manual og udelukkende
Læs mereUnited Nations Secretariat Procurement Division
United Nations Secretariat Procurement Division Vendor Registration Overview Higher Standards, Better Solutions The United Nations Global Marketplace (UNGM) Why Register? On-line registration Free of charge
Læs mereFiltering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.
Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Agenda Electromagnetic Compatibility (EMC) Application of Cable Ferrites Impedance
Læs mereSpecial VFR. - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone
Special VFR - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone SERA.5005 Visual flight rules (a) Except when operating as a special VFR flight, VFR flights shall be
Læs mereEASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting
LED Drivers CV EASYLINE CV 48 V EasyLine 48 V C-L 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V C-L VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT POWER
Læs mereSouth Baileygate Retail Park Pontefract
Key Details : available June 2016 has a primary shopping catchment of 77,000 (source: PMA), extending to 186,000 within 10km (source: FOCUS) 86,000 sq ft of retail including Aldi, B&M, Poundstretcher,
Læs mere3A Step-Down Voltage Regulator
3A Step-Down Voltage Regulator DESCRIPITION The series of regulators are monolithic integrated circuits that provide all the active functions for a step-down (buck) switching regulator, capable of driving
Læs mereEksempler SPSX Single Point Vejeceller Generation Vejeceller Single Point Vejecelle SPSX. Applikationer. Unikke Fordele
4000 Generation Vejeceller Single Point Vejecelle SPSX Unikke Fordele Udviklet og produceret i Danmark Fremstillet i elektropoleret rustfrit stål 1.4542 (17-4 PH) Robust kapacitiv teknologi Høj overlast
Læs mereIBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1
IBM Network Station Manager esuite 1.5 / NSM Integration IBM Network Computer Division tdc - 02/08/99 lotusnsm.prz Page 1 New esuite Settings in NSM The Lotus esuite Workplace administration option is
Læs mereDET KONGELIGE BIBLIOTEK NATIONALBIBLIOTEK OG KØBENHAVNS UNIVERSITETS- BIBLIOTEK. Index
DET KONGELIGE Index Download driver... 2 Find the Windows 7 version.... 2 Download the Windows Vista driver.... 4 Extract driver... 5 Windows Vista installation of a printer.... 7 Side 1 af 12 DET KONGELIGE
Læs mereHigh Voltage AC & DC Film Capacitors
RoHS COMPLIANT High Voltage AC & DC Film Capacitors Aerovox high voltage capacitors are constructed with metallized polypropylene film and are available in round or oval aluminum cases with four-blade
Læs mereProgrammable pressure transmitters PTM
Programmable pressure transmitters PTM Version: 07.01.2016 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure
Læs mereInstructions for use www.nilfisk-advance.com 1 2 3 PRECAUTIONARY MEASURES If the opening that sucks in the air, thesuction pipe orthe telescopic wand on pipe are blocked, you should switch off the vacuum
Læs mereModel Brugsanvisning Instruction manual
Model 11560 Brugsanvisning Instruction manual DK GB CAMPINGTOILET Dele Toiletlåg Toiletsæde Vandpåfyldningsstuds Pumpestempel Låsebeslag 10 liters skylletank Tømmetud Skyderventil Niveauindikator 20 liters
Læs mereBioLite NET Innovative Fingerprint Terminal
www.supremainc.com BioLite NET Innovative Fingerprint Terminal User Guide User guide( (ver 1.0 ) 1.0) Product Contents Basic Contents Product Contents E-ring Main Body Default Sub bracket (optional) Wall-mounting
Læs mereHR7775, HR7774. 4203.000.5832.4.indd 1 15-09-09 15:28
HR7775, HR7774 4203.000.5832.4.indd 1 15-09-09 15:28 EN DA DE EL ES FI FR IT NL NO PT SV TR English Dansk Deutsch Ελληνικα Español Suomi Français Italiano Nederlands Norsk Português Svenska Türkçe AR FA
Læs mereBlack Jack --- Review. Spring 2012
Black Jack --- Review Spring 2012 Simulation Simulation can solve real-world problems by modeling realworld processes to provide otherwise unobtainable information. Computer simulation is used to predict
Læs mereTELT. Oversigt over dele. Følg opstillingsanvisningerne for at opnå det bedste resultat.
TELT Følg opstillingsanvisningerne for at opnå det bedste resultat. Opstillingstid: ca. 25 min. Krævet antal personer til opstilling: 2 Oversigt over dele Kabine Pløkker (18 stk.) Yderdug Bæretaske Ekstra
Læs mereLINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc.
LINK-56K Emulator for Motorola s DSPs A Product of Domain Technologies, Inc. LINK-56K User s Guide, Version1.05 September, 2003 DSPs supported by this product: Motorola DSP56001 Motorola DSP56002 and derivatives
Læs mereLast Lecture CS Amp. I D V B M 2. I bias. A v. V out. V in. Simplified Schematic. Practical Implementation V GS
Output Range INEL 565 Analog Circuit Design 1/30/019 Last Lecture CS Amp. I D off ohmic sat sat ohmic ohmic I bias V B I bias V dd V dd -V ov A v Simplified Schematic Practical Implementation V ov1 V th
Læs merePARATHOM / PARATHOM PRO MR16 Electric Transformer Compatibility
/ PRO MR16 Electric Transformer Compatibility BASIC INFORMATION: 1. HOW CAN I UNDERSTAND THE FOLLOWING SHES? Compatibility to OSRAM s: -Series Circuit... Page 2 -Parallel Circuit... Page 3 Compatibility
Læs mereECE 551: Digital System * Design & Synthesis Lecture Set 5
ECE 551: Digital System * Design & Synthesis Lecture Set 5 5.1: Verilog Behavioral Model for Finite State Machines (FSMs) 5.2: Verilog Simulation I/O and 2001 Standard (In Separate File) 3/4/2003 1 ECE
Læs mereElektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav
Dansk standard Tillæg DS/IEC 60335-1/A1:2013 + Corr 1:2014 1. udgave 2014-05-08 Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Household and similar electrical appliances
Læs mereTGP 15 H. Betjeningsvejledning. Texas Power Line Pumper 2003 / 2
2003 / 2 Betjeningsvejledning Texas Power Line Pumper TGP 15 H Texas Andreas Petersen A/S Knullen 2 DK-5260 Odense S Tlf. 6395 5555 Fax 6395 5558 post@texas.dk - www.texas.dk ADVARSEL - Læs altid betjeningsvejledningen
Læs mereRoE timestamp and presentation time in past
RoE timestamp and presentation time in past Jouni Korhonen Broadcom Ltd. 5/26/2016 9 June 2016 IEEE 1904 Access Networks Working Group, Hørsholm, Denmark 1 Background RoE 2:24:6 timestamp was recently
Læs mereLæs venligst Beboer information om projekt vandskade - sikring i 2015/2016
Læs venligst Beboer information om projekt vandskade - sikring i 2015/2016 Vi er nødsaget til at få adgang til din lejlighed!! Hvis Kridahl (VVS firma) har bedt om adgang til din/jeres lejlighed og nøgler,
Læs mereLovkrav vs. udvikling af sundhedsapps
Lovkrav vs. udvikling af sundhedsapps Health apps give patients better control User Data Social media Pharma Products User behaviour Relatives www Self monitoring (app) data extract Healthcare specialists
Læs mere4-POLE MAGNETIC CONTACTORS
4-POLE MAGNETIC CONTACTORS FRAME SIZE OVERVIEW 18AF P/N: MRC-9B/4~MRC-18B/4 9 18 Amp Rating Inductive/Standard Contactor Coil 225AF P/N: MRC-100A/4~MRC-225A/4 100 225 Amp Rating Electronic Contactor Coil
Læs mereVentilation. Du skal selv være med til at holde din lejlighed sund You are responsible too: keep your apartment healthy
Ventilation Du skal selv være med til at holde din lejlighed sund You are responsible too: keep your apartment healthy Ventilation Ventilation Din lejlighed er renoveret, for at du skal have et sundt indeklima.
Læs mereBookingmuligheder for professionelle brugere i Dansehallerne 2015-16
Bookingmuligheder for professionelle brugere i Dansehallerne 2015-16 Modtager man økonomisk støtte til et danseprojekt, har en premieredato og er professionel bruger af Dansehallerne har man mulighed for
Læs mereFejlbeskeder i SMDB. Business Rules Fejlbesked Kommentar. Validate Business Rules. Request- ValidateRequestRegist ration (Rules :1)
Fejlbeskeder i SMDB Validate Business Rules Request- ValidateRequestRegist ration (Rules :1) Business Rules Fejlbesked Kommentar the municipality must have no more than one Kontaktforløb at a time Fejl
Læs mereRAVE. The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications
RAVE The New Radar Motion Sensor Rated IP67: Optimized for Harsh Outdoor Applications Product Presentation RAVE radar motion sensor In addition to the RaDec and RMS product families, the new RAVE radar
Læs mereBetjeningsvejledning
Betjeningsvejledning Baby Cam BC-10 Version 1.3 ease read this user manual carefully before using this produc 1 ilure to understand operation procedures may result in injury Packing List Packing List Indhold
Læs mereDK - Quick Text Translation. HEYYER Net Promoter System Magento extension
DK - Quick Text Translation HEYYER Net Promoter System Magento extension Version 1.0 15-11-2013 HEYYER / Email Templates Invitation Email Template Invitation Email English Dansk Title Invitation Email
Læs mereROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning. ROTATING SHOWER STOOL WITH TRAY Installation Manual. Size: 148 x 210 mm 105g copper paper
Size: 148 x 210 mm 105g copper paper ROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning ROTATING SHOWER STOOL WITH TRAY Installation Manual Model. 10853 1. Fjern emballagen. 2. Taburettens ben samles
Læs mereMust I be a registered company in Denmark? That is not required. Both Danish and foreign companies can trade at Gaspoint Nordic.
General Questions What kind of information do you need before I can start trading? Please visit our webpage www.gaspointnordic.com under the heading How to become a participant Is it possible to trade
Læs mereSubject to terms and conditions. WEEK Type Price EUR WEEK Type Price EUR WEEK Type Price EUR WEEK Type Price EUR
ITSO SERVICE OFFICE Weeks for Sale 31/05/2015 m: +34 636 277 307 w: clublasanta-timeshare.com e: roger@clublasanta.com See colour key sheet news: rogercls.blogspot.com Subject to terms and conditions THURSDAY
Læs mereIBM WebSphere Operational Decision Management
IBM WebSphere Operational Decision Management 8 0 29., WebSphere Operational Decision Management 8, 0, 0. Copyright IBM Corporation 2008, 2012. ........... 1 :......... 1 1: Decision Center....... 3 1
Læs mereMandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.
Mandara 1,884 sq. ft. Tradition Series Exterior Design A Exterior Design B Exterior Design C Exterior Design D 623.935.6700 robson.com Tradition Series Exterior Design A w/opt. Golf Cart Garage Exterior
Læs mereFIST-GPS3 I N S T A L L A T I O N S I N S T R U K S
FIST-GPS3 I N S T A L L A T I O N S I N S T R U K S GPSTF-patchbakker monteret med prætermineret kabel UDARBEJDET I SAMARBEJDE MED TDC Indhold 1 General information 2 Kit indhold 3 Montering af skuffer
Læs mereEngelsk. Niveau D. De Merkantile Erhvervsuddannelser September Casebaseret eksamen. og
052431_EngelskD 08/09/05 13:29 Side 1 De Merkantile Erhvervsuddannelser September 2005 Side 1 af 4 sider Casebaseret eksamen Engelsk Niveau D www.jysk.dk og www.jysk.com Indhold: Opgave 1 Presentation
Læs merehow to save excel as pdf
1 how to save excel as pdf This guide will show you how to save your Excel workbook as PDF files. Before you do so, you may want to copy several sheets from several documents into one document. To do so,
Læs mereDate of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO
JENSEN CLASSIC FOLDER JENSEN MAX STACKER MANUAL MANUAL Date of issue 2005.11.04 Fremstillingsdato Machine no. 760790, 492147 Maskinnr. Distributor / Forhandler Project Manufacturer / Fabrikant JENSEN USA
Læs mereSamlevejledning til tremmeseng 70 x 140 Assembly instruction for cot 70 x 140
Samlevejledning til tremmeseng 70 x 140 Assembly instruction for cot 70 x 140 Læs vejledningen godt igennem før du begynder. Read the assembly instruction carefully before you start. OLIVER FURNITURE /
Læs mere