LED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit. www.osram.com 1. HOW CAN I UNDERSTAND THE FOLLOWING SHEETS?



Relaterede dokumenter
UNISONIC TECHNOLOGIES CO.,

Basic statistics for experimental medical researchers

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

Vina Nguyen HSSP July 13, 2008

Engelsk. Niveau D. De Merkantile Erhvervsuddannelser September Casebaseret eksamen. og

Brugsanvisning. Installation Manual

Reventlow Lille Skole

Sikkerhedsvejledning

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

Danish Language Course for International University Students Copenhagen, 12 July 1 August Application form

Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov.

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

DEKRA hereby grants the right to use the ENEC KEMA-KEUR certification mark.

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

Privat-, statslig- eller regional institution m.v. Andet Added Bekaempelsesudfoerende: string No Label: Bekæmpelsesudførende

Unitel EDI MT940 June Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

PARALLELIZATION OF ATTILA SIMULATOR WITH OPENMP MIGUEL ÁNGEL MARTÍNEZ DEL AMOR MINIPROJECT OF TDT24 NTNU

Danish Language Course for Foreign University Students Copenhagen, 13 July 2 August 2016 Advanced, medium and beginner s level.

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

Financial Literacy among 5-7 years old children

Engelsk. Niveau C. De Merkantile Erhvervsuddannelser September Casebaseret eksamen. og

User Manual for LTC IGNOU

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

Skriftlig Eksamen Kombinatorik, Sandsynlighed og Randomiserede Algoritmer (DM528)

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.

Subject to terms and conditions. WEEK Type Price EUR WEEK Type Price EUR WEEK Type Price EUR WEEK Type Price EUR

DENCON ARBEJDSBORDE DENCON DESKS

TDC 4 Indoor voltage transformers

Slot diffusers. Slot diffusers LD-17, LD-18

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

DET KONGELIGE BIBLIOTEK NATIONALBIBLIOTEK OG KØBENHAVNS UNIVERSITETS- BIBLIOTEK. Index

IPTV Box (MAG250/254) Bruger Manual

Hvor er mine runde hjørner?

The X Factor. Målgruppe. Læringsmål. Introduktion til læreren klasse & ungdomsuddannelser Engelskundervisningen

Varenr.: højre venstre º højre med coating º venstre med coating

Help / Hjælp

GUIDE TIL BREVSKRIVNING

Side 1 af 9. SEPA Direct Debit Betalingsaftaler Vejledning

Engelsk 8. klasse årsplan 2018/2019

LESSON NOTES Extensive Reading in Danish for Intermediate Learners #8 How to Interview

Molio specifications, development and challenges. ICIS DA 2019 Portland, Kim Streuli, Molio,

Rasmus Banke Banke Accessory Drives

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen

Small Autonomous Devices in civil Engineering. Uses and requirements. By Peter H. Møller Rambøll

MEGAMAN LED AR111 15W ER2015d-75H24D, ER2115d-75H08D and ER2215d-75H45D

SEPA Direct Debit. Mandat Vejledning Nets Lautrupbjerg 10 DK-2750 Ballerup

Barnets navn: Børnehave: Kommune: Barnets modersmål (kan være mere end et)

Must I be a registered company in Denmark? That is not required. Both Danish and foreign companies can trade at Gaspoint Nordic.

Sikkerhed & Revision 2013

FØDEVARE EGNEDE PLASTPOSER, SAMT EMBALLAGE FOLIER.

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

BANGKOK FASE 2 - VALGFAG INFORMATION, VEJLEDNING OG DOKUMENTER

Fejlbeskeder i SMDB. Business Rules Fejlbesked Kommentar. Validate Business Rules. Request- ValidateRequestRegist ration (Rules :1)

Hi-Res Audio/DNC Headset MDR-NC750

Special VFR. - ved flyvning til mindre flyveplads uden tårnkontrol som ligger indenfor en kontrolzone

Lovkrav vs. udvikling af sundhedsapps

frame bracket Ford & Dodge

Generalized Probit Model in Design of Dose Finding Experiments. Yuehui Wu Valerii V. Fedorov RSU, GlaxoSmithKline, US

DK - Quick Text Translation. HEYYER Net Promoter System Magento extension

Aktivering af Survey funktionalitet

Tidevandstabeller for danske farvande. Tide tables for Danish waters

Our activities. Dry sales market. The assortment

High Voltage AC & DC Film Capacitors

Skriftlig Eksamen Diskret matematik med anvendelser (DM72)

Page 2: Danish. Page 4: English

Titel: Barry s Bespoke Bakery

SmartDock for Xperia ion Brugervejledning

EuroForm OCR-B Installation Guide

Linear Programming ١ C H A P T E R 2

Engelsk 6. klasse årsplan 2018/2019

Transkript:

BASIC INFORMATION: 1. HOW CAN I UNDERSTAND THE FOLLOWING SHES? Compatibility to OSRAM s: -Series Circuit... Page 2 -Parallel Circuit... Page 3 Compatibility to OTHER s : -Series Circuit... Page 4 -Parallel Circuit... Page 5 Series circuit Parallel circuit 2. WHAT IS THE PRODUCT CODE AND WHERE DO I FIND IT? The product code describes the lamp type. It contains 7 letters and digits and is starting with A. Example for the product code on the stamp of the lamp: AA37362 3. HOW MANY LAMPS CAN I INSTALL ON ONE? For max. number of lamps on a, please use the following rule of thumb: (Please note: actual number my vary from calculated result) Max load of equivalent wattage (HAL/GLS) = max. number of lamps 4. HOW CAN I READ THE FOLLOWING CHARTS? Legend: Information about the of the lamps and s. means very habits, red means partial critical habits. List of beeing tested in the laboratory Information about the OSRAM lamp type Number of lamps tested on an Test results of according to the traffic light system Example: works very well for one LED STAR MR16 20 lamp. 1

Compatibility without Dimmer OSRAM s on series circuit Compatibility very (no problems with ) AB31244 Number of Lamps on : Brand Model Voltage range Power 1 2 3 4 OSRAM -MZ 60/110-130 110-130, 50-60Hz 20-60 OSRAM -A 60/220-240 220-240, 50-60Hz 20-60 OSRAM -C 70/220-240 220-240, 50-60Hz 20-70 OSRAM -Z 60/220-240 220-240, 50-60Hz 20-60 OSRAM -ZL 50/220-240 220-240, 50-60Hz 50 OSRAM -ZE 60/220-240 220-240, 50-60Hz 20-60 OSRAM -P 60/220-240 (Gen 1) 220-240, 50-60Hz 20-60 OSRAM -P 60/220-240 (Gen 2) 220-240, 50-60Hz 20-60 OSRAM -Parrot 70/220-240 I 220-240, 50-60Hz 20-70 OSRAM -Parrot 105/220-240 I 220-240, 50-60Hz 35-105 OSRAM -Parrot 150/220-240 I 220-240, 50-60Hz 50-150 OSRAM T-E60I/220-240 220-240, 50-60Hz 20-60 OSRAM -back 60/230-240 230-240, 50Hz 20-60 OSRAM HTB 70/220-240 220-240, 50-60Hz 20-70 HT OSRAM HTB 105/220-240 220-240, 50-60Hz 35-105 HT OSRAM HTB 70/230-240 230-240, 50Hz 20-70 HT OSRAM HTN 75/230-240 I 230-240, 50-60Hz 20-75 HT OSRAM HTM 70/230-240 230-240, 50-60Hz 20-70 HT OSRAM HTM 105/230-240 230-240, 50-60Hz 35-105 HT OSRAM HTM 150/230-240 230-240, 50-60Hz 50-150 HT OSRAM HTL105/230-240 230-240, 50-60Hz 35-105 HT OSRAM HTL225/230-240 230-240, 50-60Hz 50-225 HT OSRAM OT 12/220-240/10 220-240, 50-60Hz 0.5-12 OT OSRAM OT 15/220-240/10 220-240, 50-60Hz 0.5-15 OT OSRAM OT30/220-240/12P 230, 50Hz 0-30 OT OSRAM OT 50/220-240/10 220-240, 50-60Hz 0-50 OT OSRAM OTe 35/220-240/12 220-240, 50-60Hz 1.0-35 OT OSRAM OT 20/220-240/24 220-240, 50-60Hz 0.5-20 OT OSRAM OT60/220-240/12P 230, 50Hz 0-60 OT OSRAM OT 75/220-240/24 220-240, 50-60Hz 0-75 OT OSRAM OTe 18/220-240/24 220-240, 50-60Hz 1.0-18 OT OSRAM Hti DALI 105/230-240 DIM 230-240, 50-60Hz 35-105 HTi OSRAM Hti DALI 150/220-240 DIM 220-240, 50-60Hz 35-150 HTi 2

Compatibility without Dimmer OSRAM s on parallel circuit Compatibility very (no problems with ) AB31244 Number of Lamps on : Brand Model Voltage range Power 1 2 3 4 OSRAM -MZ 60/110-130 110-130, 50-60Hz 20-60 OSRAM -A 60/220-240 220-240, 50-60Hz 20-60 OSRAM -C 70/220-240 220-240, 50-60Hz 20-70 OSRAM -Z 60/220-240 220-240, 50-60Hz 20-60 OSRAM -ZL 50/220-240 220-240, 50-60Hz 50 OSRAM -ZE 60/220-240 220-240, 50-60Hz 20-60W OSRAM -P 60/220-240 (Gen 1) 220-240, 50-60Hz 20-60 OSRAM -P 60/220-240 (Gen 2) 220-240, 50-60Hz 20-60 OSRAM -Parrot 70/220-240 I 220-240, 50-60Hz 20-70 OSRAM -Parrot 105/220-240 I 220-240, 50-60Hz 35-105 OSRAM -Parrot 150/220-240 I 220-240, 50-60Hz 50-150 OSRAM T-E60I/220-240 220-240, 50-60Hz 20-60 OSRAM -back 60/230-240 230-240, 50Hz 20-60 OSRAM HTB 70/220-240 220-240, 50-60Hz 20-70 HT OSRAM HTB 105/220-240 220-240, 50-60Hz 35-105 HT OSRAM HTB 70/230-240 230-240, 50Hz 20-70 HT OSRAM HTN 75/230-240 I 230-240, 50-60Hz 20-75 HT OSRAM HTM 70/230-240 230-240, 50-60Hz 20-70 HT OSRAM HTM 105/230-240 230-240, 50-60Hz 35-105 HT OSRAM HTM 150/230-240 230-240, 50-60Hz 50-150 HT OSRAM HTL105/230-240 230-240, 50-60Hz 35-105 HT OSRAM HTL225/230-240 230-240, 50-60Hz 50-225 HT OSRAM OT 12/220-240/10 220-240, 50-60Hz 0.5-12 OT OSRAM OT 15/220-240/10 220-240, 50-60Hz 0.5-15 OT OSRAM OT30/220-240/12P 230, 50Hz 0-30 OT OSRAM OT 50/220-240/10 220-240, 50-60Hz 0-50 OT OSRAM OTe 35/220-240/12 220-240, 50-60Hz 1.0-35 OT OSRAM OT 20/220-240/24 220-240, 50-60Hz 0.5-20 OT OSRAM OT60/220-240/12P 230, 50Hz 0-60 OT OSRAM OT 75/220-240/24 220-240, 50-60Hz 0-75 OT OSRAM OTe 18/220-240/24 220-240, 50-60Hz 1.0-18 OT OSRAM Hti DALI 105/230-240 DIM 230-240, 50-60Hz 35-105 HTi OSRAM Hti DALI 150/220-240 DIM 220-240, 50-60Hz 35-150 HTi 3

Compatibility without Dimmer Other s on series circuit Compatibility very (no problems with ) habits habits AB31244 EAN Number of Lamps on : Brand Model Voltage range Power 1 2 3 4 SLV 461060 230, 50-60Hz 10-60 SLV 461310 230,50Hz 35-105 BLOCK HES 70K 230-240,50-60Hz 20-70 BLOCK HES 105K 230-240,50-60Hz 35-105 EVN TAB 70 (3110) 230,50-60Hz 20-70 EVN TAB 70 (3310) 230,50-60Hz 20-70 EVN TAB 50(0410) 230,50-60Hz 20-50 EVN CLOU 60(T41/09) 230-240,50-60Hz 10-60 EVN MINIJOKER 70(T27/10) \ 70 Berker lgel 20-105w 2921 230-240,50-60Hz 20-105 Berker SNT 70/QU 2918 230,50-60Hz 20-70 Berker SNTF 105 297401 230,50-60Hz 20-105 Berker SNTF II 35-105W 2927 230,50-60Hz 35-105 HT Berker SNT 40 2915 230,50-60Hz 10-40 TCI SHARK60 220-240,50-60Hz 10-60 TCI PUMA 60 230-240,50-60Hz 20-60 TCI EF 70 230,50-60Hz 20-70 TCI PUMA 105 230-240,50-60Hz 20-105 TCI ROUND 70 230,50-60Hz 20-70 TCI ROUND 50 230,50-60Hz 10-50 BRUMBERG 54211 220-240,50-60Hz 35-105 BRUMBERG 54271 230-240,50-60Hz 35-105 Paulmann Disc electronic S 70 230,50-60Hz 20-70 Paulmann Euro S 70 230,50-60Hz 20-70 Paulmann Profi 50 220-240,50Hz 10-50 Paulmann Profi 80 220-240,50Hz 20-80 Paulmann Mipro 70 230,50-60Hz 20-70 Paulmann Mipro 105 230,50-60Hz 35-105 JUNG SNT 70 Q 230,50-60Hz 20-70 JUNG SNT 40 230,50-60Hz 10-40 JUNG SNT 70 F 230,50-60Hz 20-70 JUNG SNT 105 F 230,50-60Hz 20-105 nobile EN-80F 230,50-60Hz 20-80 nobile EN-60D2 230,50-60Hz 20-60 nobile EN-60D 230,50-60Hz 20-60 nobile EN-35R 230,50-60Hz 10-35 KTB MBL 120 230,50-60Hz 20-120 FN LIGHT TL105S 20-105W 461107 230-240,50-60Hz 20-105 bay S110LV(35-110W) 220-240,50Hz 35-110 PHILIPS Primaline 70 230-240 230-240,50-60Hz 20-70 abi S210(50-210VA) AL50476 220-240V, 50Hz 50-210 abi S60T-EL AL50460 220-240V, 50Hz 10-60 abi-aurora AU-E60 240V, 50/60Hz 10-60 abi G-60T AL50462 220-240V, 50Hz 10-60 Radium Ralotronic SMART D 70 230-240V,50-60Hz 20-70 Radium Ralotronic SMART D 105 230-240V,50-60Hz 35-105 4

Compatibility without Dimmer Other s on parallel circuit Compatibility very (no problems with ) habits habits AB31244 EAN Number of Lamps on : Brand Model Voltage range Power 1 2 3 4 SLV 461060 230, 50-60Hz 10-60 SLV 461310 230,50Hz 35-105 BLOCK HES 70K 230-240,50-60Hz 20-70 BLOCK HES 105K 230-240,50-60Hz 35-105 EVN TAB 70 (3110) 230,50-60Hz 20-70 EVN TAB 70 (3310) 230,50-60Hz 20-70 EVN TAB 50(0410) 230,50-60Hz 20-50 EVN CLOU 60(T41/09) 230-240,50-60Hz 10-60 EVN MINIJOKER 70(T27/10) \ 70 Berker lgel 20-105w 2921 230-240,50-60Hz 20-105 Berker SNT 70/QU 2918 230,50-60Hz 20-70 Berker SNTF 105 297401 230,50-60Hz 20-105 Berker SNTF II 35-105W 2927 230,50-60Hz 35-105 HT Berker SNT 40 2915 230,50-60Hz 10-40 TCI SHARK60 220-240,50-60Hz 10-60 TCI PUMA 60 230-240,50-60Hz 20-60 TCI EF 70 230,50-60Hz 20-70 TCI PUMA 105 230-240,50-60Hz 20-105 TCI ROUND 70 230,50-60Hz 20-70 TCI ROUND 50 230,50-60Hz 10-50 BRUMBERG 54211 220-240,50-60Hz 35-105 BRUMBERG 54271 230-240,50-60Hz 35-105 Paulmann Disc electronic S 70 230,50-60Hz 20-70 Paulmann Euro S 70 230,50-60Hz 20-70 Paulmann Profi 50 220-240,50Hz 10-50 Paulmann Profi 80 220-240,50Hz 20-80 Paulmann Mipro 70 230,50-60Hz 20-70 Paulmann Mipro 105 230,50-60Hz 35-105 JUNG SNT 70 Q 230,50-60Hz 20-70 JUNG SNT 40 230,50-60Hz 10-40 JUNG SNT 70 F 230,50-60Hz 20-70 JUNG SNT 105 F 230,50-60Hz 20-105 nobile EN-80F 230,50-60Hz 20-80 nobile EN-60D2 230,50-60Hz 20-60 nobile EN-60D 230,50-60Hz 20-60 nobile EN-35R 230,50-60Hz 10-35 KTB MBL 120 230,50-60Hz 20-120 FN LIGHT TL105S 20-105W 461107 230-240,50-60Hz 20-105 bay S110LV(35-110W) 220-240,50Hz 35-110 PHILIPS Primaline 70 230-240 230-240,50-60Hz 20-70 abi S210(50-210VA) AL50476 220-240V, 50Hz 50-210 abi S60T-EL AL50460 220-240V, 50Hz 10-60 abi-aurora AU-E60 240V, 50/60Hz 10-60 abi G-60T AL50462 220-240V, 50Hz 10-60 Radium Ralotronic SMART D 70 230-240V,50-60Hz 20-70 Radium Ralotronic SMART D 105 230-240V,50-60Hz 35-105 5

Please Note: The list is based upon testing conducted by the manufacturer in a lab simulated environment, and the results can vary in certain field applications due to a number of factors. OSRAM does not take over any responsibility, warranty or liability that this results can also achieved by using the devices under other conditions, or when using successor models of the tested devices, or different models of the same manufacturer, or when using other LED lamp types The absence of an electric transformer from this chart does not necessarily imply in. Please reference the electric transformer manufacturer s instructions for installation. LED lamps contain several electronic components. Under unfavourable conditions these can lead to acoustic noise. In case of resonance even low noise can cause audible effect. Possible factors influencing this are the installation, the design of the lamp holder and the luminaire (acoustic resonance effect) as well as the dimmer or the transformer (harmonics or electronic resonance). Subject to change without notice Errors and omission excepted Always make sure to use the most recent release 6