SAB Olieprøver. For oliefyldte transformer ved Banedanmark



Relaterede dokumenter
SAB Olieprøver. For oliefyldte transformer ved Banedanmark

Olieregenerering på transformere. Bilag 1.0 Kravspecifikation vers. 2

Olieregenerering på transformatorer

Trend Analyse & Monitorering - dybdegående analyse af væskers tilstand på laboratorium

Prøveudtagning. Kirsten Jebjerg Andersen DANAK

s:c ISOLATJO: JSSYMPOSIUM

Teknisk Information fra Smøreolieafdelingen 2007/1

Installation af UPS-anlæg

Lab Advisor. Sundhedskontrol for maskiner og motorer

Screened electronic cable LiYCY

Anbefalet for installation af brandspjæld. (Installation i vertikal eller horisontal position, installation i fast og fleksibel væg.

Installation i fast væg. Installation i fast væg. Installation i fleksibel væg

kv AC Station

Eksempler for installation i væg (spjældblade inde i vægkonstruktionen)

Temadag om bygge og anlægsaffald!.

VIGTIG PRODUKTINFORMATION

Industrikompressor 2x90ltr

Control cable YSLY-JZ/-JB/-OZ/-OB

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG

Krüger a/s Veolia Water Technologies, Danmark. AARHUS Haslegårdsvænget 18 DK-8210 Aarhus V T

Anvendelsen af kulrør - kan vi optimere prøvetagningen?

Vejlesøparken, 2840 Holte Undersøgelser af PCB i indeluft i udvalgte lejligheder Sag nr.: R

Foreningen af Sygehusmaskinmestre i Danmark. Kontrolprogram. Version 1. Kontrolskemaer

Egedal Kommune TEKNISK NOTAT SCREENING FOR PCB I INDELUFT. Adresse: Rådhustorvet 6 Postnummer og by: 3660 Stenløse

Olieregenerering på transformatorer

INSTALLATIONSVEJLEDNING BRANDSPJÆLD FDMC

XO Osseo på XO 4 Unit Brugervejledning

Kravspecifikation. 60/10 kv transformer. med gennemføringer

Kontrolrapport. Den 6. og 9. december 2011 foretog atter skimmelundersøgelse i ovennævnte bolig, og udtog prøver til laboratorieanalyse.

TEKNISK RAPPORT. Test af overflademodstand og isolationsmodstand for sugearme. Omfang:

Undersøgelse af danske institutters og firmaers muligheder for at servicere danske virksomheder inden for typeprøvning af legale måleinstrumenter

Der kan eventuelt blive behov for en mindre justering af dansk regulering (svovlbekendtgørelsen) som følge af Kommissionsbeslutningen.

1 INDLEDNING PCB MÅLING AF INDEKLIMAET HISTORIK ANALYSERESULTATER Resultater for indhold af PCB i luft...

High-performance kædeolier

Hvis dette kunne have jeres interesse vil jeg meget gerne være behjælpelig med yderlig information og evt. tilbud.

Koster Crop Tester Tørstofmåler til foder

kv AC Station

Den Europæiske Unions Tidende L 192/51 DIREKTIVER

Kontrolsystem for vandmålere i drift. Juli 2017

Indhold. Ringsted Kommune Skjoldenæsholm Sedimentundersøgelse. 1 Baggrund 2

Supplerende PCB-målinger efter iværksættelse

Industrikompressor 2x90ltr

Måling af partikelforureningen i Søgaderne

1ZSE da, Rev. 3. Effektviklingskoblere, type UC og VUC Brugervejledning

Brunata ClickOnETJ + med radiotelegram version 1 og 2

Instruks vedrørende. el-installatørers

DANPURE HOME 200 TDS,

Bilagsrapport 7: Analyse af malingaffald fra husholdninger i Århus Kommune

NOTAT. 1. Kontrolmålinger på Skolen ved Stadion i forbindelse med PCB-forsegling

Kortlægning af miljøfremmede stoffer og materialer? Kirill Kongstad og Niels Trap

Installation Venligst bemærk, håndpumpen kun må monteres i lodret position.

Situationsplan med boringer. Analyseresultater VERSION UDGIVELSESDATO BESKRIVELSE UDARBEJDET KONTROLLERET GODKENDT

Måleteknisk direktiv (Vejledning) FJERNVARMEMÅLERE. Kontrolsystem for målere i drift. MDIR , udg. 3

DANPURE OFFICE 1500 TDS,

Egenskaber Test/Standard Beskrivelse. mat (0-35) Flammepunkt ISO 3679 Method 1 16 C beregnet VOC-US/Hong Kong. US EPA method 24 (testet)

Viborg Spildevand A/S Sendt pr. til:

PRODUKTIONSSTYRING FOR SAND, GRUS OG STEN TIL VEJBYGNING

afindeluftindeluften Måling af PCB Måling af PCB i indeluft på Tommerup skole Supplerende målinger Stadionvænget 7, 5690 Tommerup

English version is included. Eltransmission og eksterne leverandører. Forfatter Reviewer Godkender Revision

Vejledning for indretning og drift af olieudskilleranlæg i Skive Kommune

62.00 TRANSFORMERE POLYLUX TRANSFORMERE POLYLUX TRANSFORMERE transformere.

Industrikompressor 2x90ltr

Videreudvikling af LDV til on-sitemåling

Manual C C C C C C 7 4. Klippe maskine for jernstænger

2.. Anden prøvetagning af frø, herunder prøvetagning af udenlandske partier.

Elektrisk (grund)teori Niveau F 60/10 kv forsyningstransformer på Bedsted Friluftsstation (foto Peter Valberg) september 2005

Power IT Compact Secondary Substations, CSS. Lavspændingstavler, LVS3

1ZSE da, Rev. 4. Effektviklingskoblere, type UC Brugervejledning

Arbejde med vandledninger

Metal Oxide Varistor:TVM-B Series

Måleinstrumentdirektivets betydning for danske fabrikanter og brugere En spørgeundersøgelse

Rekommandation kv olieisolerede Shuntreaktorer. 1. udgave

Status for svovlregulering

Regulativ for modtagelse og behandling af spildevandsslam på rensningsanlæg. Teknik & Miljø Esbjerg Kommune

Betydning af erstatning af DS metoder med EN metoder - Farvetal

Martin Professional A/S. Analyse af Flash Component og renhed på printkort

Miljøteknisk rapport. Sag: J M2 Bakkegårdsvej 8, Vivild, Allingåbro. Risikovurdering af indeklima og udeluft. Horsens, den 5.

Ændringshistorik TB for DRV i henhold til EN 1279, 1. udgave, juni 2014 rev. 1, januar 2016 Dansk

BRUGERVEJLEDNING D250TS

Beton Materialer Regler for anvendelse af EN i Danmark

Brugsanvisning til Poda SMS Alarm

LEVERANDØRBRUGSANVISNING

Produktoversigt DST-DEGREEZ DERUST DST-PAS DST-DEBURR.

Miljøpulje for spildolie

Anvendelsesområder for rørsystemer af metal

3M Karrosserilim

Montagevejledning RIOpanel Integra

Nye metoder til bestemmelse af KCl i halm

Prøvningsmetoder til kvantitativ bestemmelse af ætsende svovlforbindelser

Idrifttagningsprotokol BSW 6-21 B

Sikkerhedsdatablad. Sikkerhedsdatablad Koldpresset Rapsolie Rev. dato: : Identifikation af stoffet og af virksomheden

Hovedinspektion af legepladsredskaber udarbejdet for: Aulum Byskole

Approved. Egenskaber Test/Standard Beskrivelse Tørstofindhold efter volumen ISO 3233 Glansgrad (GU 60 ) ISO 2813 Flammepunkt ISO 3679 Method 1 26 C

Temamøde Installationer Specielle emner. Velkommen

Indhold. Horsens Vand A/S Alrøvej Horsens tlf.:

NÆRINGSINDHOLD I HVEDE OG RUG FRA EGEN BEDRIFT VARIERER KUN LIDT

ADDITIVES. Add power to your car.

INSTRUKTIONSBOG HORISONTALBLANDER

Oliefyldte kabelsamlinger til transformere og reaktorer med højeste spænding til udstyr Um fra 72,5 kv til 550 kv Del 1: Væskefyldte kabelafslutninger

Forsøgsrapport. NOVA 5 arkitekter a/s Sankt Annæ Passage opgang G 1262 København K Sag nr: PE Ref: SBJ/MLB/sbj Bilag: 20

Transkript:

SAB Olieprøver For oliefyldte transformer ved Banedanmark Dokument: SAB Olieprøver Udgave: Udg. 02 Udgavedato: 2014-11-12 Udarbejdet af: Kontrolleret af: Godkendt af: Banedanmark Teknisk Drift Vasbygade 10 2450 København SV SVBR DRCE/KDU ESK-JOR Tlf. 82 34 00 00

Indholdsfortegnelse 1. INDLEDNING 1 2. Prøveintervaller - Krafttransformere 3 Kørestrømsanlæg krafttransformere 132/27,5 kv og 150/27,5 kv. 3 2.01. Årlig prøver 3 2.02. Hvert 3. År 3 Kørestrømsanlæg ensrettertransformere 30/1.3 kv-10/1.3 kv. 3 2.03. Årlig prøver 3 2.04. Hvert 3. År 3 3. Udvidet prøver Krafttransformere / Ensrettertransformere 30/1.3 kv-10/1.3 kv. 4 3.01. Udvidet prøve 1 4 3.02. Udvidet prøve 2 4 3.03. Udvidet prøve 3 4 3.04. Udvidet prøve 4 4 3.05. Udvidet prøve 5 4 4. Prøveintervaler - SUFO 4 Kørestrømsanlæg omfatter Sugetransformere 27.5 kv med åbne konservator. 4 4.01. Årlig prøver 4 4.02. Hvert 4. År 4 Kørestrømsanlæg omfatter Sugetransformere 27,5kV hermetisk lukkede. 5 4.03. Årlig prøver 5 4.04. Hvert 4. År 5 5. Prøveintervaler - Togforvarmeanlæg 5 Togforvarmeanlæg omfatter 10/1,5 kv med åben konservator. 5 5.01. Årlig prøver 5 5.02. Hvert 4. År 5 5.03. Udvidet prøver 5 5.04. Årlig prøver 5 5.05. Hvert 4. År 5 5.06. Udvidet prøver 5 6. Prøveintervaler - Skilletransformere 0,4 / 0,4 kv 6 6.01. Årlig prøver 6 6.02. Hvert 4. År 6 6.03. Udvidet prøver 6 6.04. Årlig prøver 6 6.05. Hvert 4. År 6 6.06. Udvidet prøver 6 7. Udtagning af olieprøver 6 8. Laboratorium 8 9. Annex A 9 10. Annex B 9

1. INDLEDNING Alt arbejde beskrevet i SAB Olieprøver skal udføres i overensstemmelse med Stærkstrømsbekendtgørelsen afsnit 5 og i samarbejde med Banedanmark`s driftsledere og det pågældende forsyningsselskabs driftsleder og dennes netkontrol. Denne arbejdsbeskrivelse beskriver olieanalyser og prøvetagning af olie på Banedanmarks transformere til bla.. Kørestrømsanlæg. Togforvarmeanlæg. Forsyningstransformere fra højspændingsnet og til 400 V Skilletransformere 0.4 / 0.4 kv. SAB olieprøver omfatter krav til indsamling, analyse og evaluering af olieprøver for ovennævnte transformertyper fyldt med mineralolie. SAB olieprøver angiver krav til entreprenører og den metode, der skal følges ved prøveudtagning, efterfølgende analyse og rapportering samt anbefalede grænseværdier. SAB olieprøver er baseret på eksisterende IEC anbefalinger og historiske data hos Banedanmark. Formålet med disse krav er at have en ensartet metode fra prøveudtagning til den endelige evalueringsrapport så Banedanmark ikke bliver udsat for rapporter baseret på fejlagtige prøvetagning og unøjagtige analyse og ikke udsat for rapporter af varierende design eller tvetydige anbefalinger. 1

1.1. Standarder A. IEC 60422 ED 4, 2013 Supervision and maintenance guide for mineral insulating oils in electrical equipment. B. IEC 60475 Method of sampling of dielectrics. C. IEC 60567 Guide for the sampling of gases and oil from oil-filled electrical equipment and for the analysis of free and dissolved gases. D. IEC 60599 Mineral oil-impregnated electrical equipment in service Guide to the interpretation of dissolved and free gases. E. IEC 60156/9 Dielectric strength. F. IEC 60814 Moisture G. ASTM D1500 Colour H. IEC 62535 Corrosive sulphur. I. ASTM D1275:2006, Standard Test Method for Corrosive Sulfur in Electrical Insulating Oils J. DIN 51353: Testing of insulating oils; Detection of corrosive sulphur; Silver strip test K. DBDS (ECD) IEC62697-1 L. Passivator Irg. 39 IEC 60666 M. CIGRE WG A2-32 Copper sulphide in transformer insulation - Final Report. N. GCC-CIGRE 2009_paper_VanderTumiatti.pdf O. IEC 60666 Anti-oxidant additives. P. IEC 60666 Inhibitor; Inhibited (see Anti-oxidant additives) Q. IEC 61198 Total fufural and furans. R. IEC 60970 Particle Count. S. ABB AB Power Transformers; Produktinformation Nr. 1ZSE 209 001-6; dato 2104-02-06 sida 1 2

T. ABB AB Power Transformers; Produktinformation Nr 1ZSE 209 001-4, dato 2010-02-09, sida 1: Provtagning För Gasanalyse och Oljekvalitetsprov. Disse standarder er grundlaget for prøvetagning, analyse og vurdering. Entreprenøren kan afvige fra disse specifikationer efter godkendelse fra Banedanmark. Anvendt benævnelse i tekst: DGA: Gasanalyse GOT: Generel Olie Test. 2. Prøveintervaller - Krafttransformere Kørestrømsanlæg krafttransformere 132/27,5 kv og 150/27,5 kv. 2.01. Årlig prøver DGA: Gasanalyse Ved evt. påfyldning af Passivator Irg. 39 aftales interval efter instruks fra laboratorium med baggrund i nedslidning af passivator indhold. 2.02. Hvert 3. År DGA: Gasanalyse, GOT: Visuel bedømmelse, farve, gennemslagsspænding, syretal, fugtindhold, grænsefladespænding (IFT), beregnet vandindhold i cellulose, dielektrisk tabsfaktor (DDF), inhibitorindhold. Kørestrømsanlæg ensrettertransformere 30/1.3 kv-10/1.3 kv. 2.03. Årlig prøver DGA: Gasanalyse 2.04. Hvert 3. År DGA: Gasanalyse, 3

GOT: Visuel bedømmelse, farve, gennemslagsspænding, syretal, fugtindhold, grænsefladespænding (IFT), beregnet vandindhold i cellulose, dielektrisk tabsfaktor (DDF), inhibitorindhold 3. Udvidet prøver Krafttransformere / Ensrettertransformere 30/1.3 kv-10/1.3 kv. 3.01. Udvidet prøve 1 Furan analyse. 3.02. Udvidet prøve 2 Test for kobber korrosion i olien. 3.03. Udvidet prøve 3 Test for DBDS indhold. 3.04. Udvidet prøve 4 Test af Passivator når det er påfyldt. Interval efter instruks fra laboratorium med baggrund i hastighed for nedslidning af passivatorindhold. Normalt vil det være efter 3 mdr.; 6 mdr og 9 mdr.indtil en trend kurver er fastlagt. Beskrevet i IEC 60422 ED 4 afsnit 13 Passivation 3.05. Udvidet prøve 5 Papirprøve for test af DP - værdi. 4. Prøveintervaler - SUFO Kørestrømsanlæg omfatter Sugetransformere 27.5 kv med åbne konservator. 4.01. Årlig prøver 4.02. Hvert 4. År DGA Gasanalyse, efter aftale. GOT: Visuel bedømmelse, farve, gennemslagsspænding, syretal, fugtindhold, grænsefladespænding (IFT), beregnet vandindhold i cellulose, inhibitorindhold. 4

Kørestrømsanlæg omfatter Sugetransformere 27,5kV hermetisk lukkede. Særlig instruks ifølge fabrikant. 4.03. Årlig prøver 4.04. Hvert 4. År 5. Prøveintervaler - Togforvarmeanlæg Togforvarmeanlæg omfatter 10/1,5 kv med åben konservator. 5.01. Årlig prøver 5.02. Hvert 4. År DGA Gasanalyse, efter aftale. DGA - Gasanalyse. GOT: Visuel bedømmelse, farve, gennemslagsspænding, syretal, fugtindhold, grænsefladespænding (IFT), beregnet vandindhold i cellulose, dielektrisk tabsfaktor (DDF), inhibitorindhold. 5.03. Udvidet prøver For udvidet prøver kan disse defineres, som beskrevet under afsnit 3 Udvidet prøver Krafttransformere Togforvarmeanlæg omfatter 10/1,5 kv hermetisk lukkede. 5.04. Årlig prøver 5.05. Hvert 4. År Særlig instruks ifølge fabrikant. 5.06. Udvidet prøver For udvidet prøver kan disse defineres, som beskrevet under afsnit 3 Udvidet prøver Krafttransformere 5

6. Prøveintervaler - Skilletransformere 0,4 / 0,4 kv 6.01. Årlig prøver 6.02. Hvert 4. År Skilletransformere omfatter 0,4 / 0,4 kv med åben konservator DGA Gasanalyse, efter aftale. DGA - Gasanalyse. GOT: Visuel bedømmelse, farve, gennemslagsspænding, syretal, fugtindhold, grænsefladespænding (IFT), beregnet vandindhold i cellulose, dielektrisk tabsfaktor (DDF), inhibitorindhold. 6.03. Udvidet prøver For udvidet prøver kan disse defineres, som beskrevet under afsnit 3 Udvidet prøver Krafttransformere Skilletransformere omfatter 0,4 / 0,4 kv hermetisk lukket. 6.04. Årlig prøver 6.05. Hvert 4. År Særlig instruks ifølge fabrikant. 6.06. Udvidet prøver For udvidet prøver kan disse defineres, som beskrevet under afsnit 3 Udvidet prøver Krafttransformere 7. Udtagning af olieprøver Prøveudtagningen skal udføres af en erfaren person, som har modtaget tilstrækkelig instruks/ uddannelse i overensstemmelse med IEC 60475 og IEC 60422. Prøveudtagning skal udføres i henhold medsendte ABB aluminiumsflaske: ABB AB Power Transformers; Produktinformation Nr. 1ZSE 209 001-6; dato 2104-02-06 sida 1 ABB AB Power Transformers; Produktinformation Nr 1ZSE 209 001-4, dato 2010-02-09, sida 1: Provtagning För Gasanalyse och Oljekvalitetsprov 6

Prøvetagning skal udføres i tørt vejr. Hvis det ikke er muligt skal man følge vejledning i IEC 60475, afsnit 2.1.4, Sampling procedure. Når det er muligt, skal olieprøver udtages når transformeren har været i drift under normale driftsbetingelser eller meget kort tid efter udkobling. Transformeren bør før prøvetagningen i længere tid have haft en jævn temperatur. Transformatorens temperatur bør ikke være under 40 0 C, hvis det skal være relevant at beregne cellulosens fugtindhold. Det er vigtigt, at sikre, at prøverne er repræsentative for transformerolien i transformeren. Prøvetagningsprocedurer skal følges så man undgår forurening i prøvebeholderen. Denne forurening, kan fører til fejlagtig bedømning og konklusion og dermed dårlig kvalitet af rapport. Olieprøverne udtages normalt fra bundventil eller fra en ventil som er mærket "Olieprøve". Nødvendig mængde olie skal "skylles" ud gennem tilpasset ventil for at flosse evt. slam og partikler væk før fyldning af aluminiumsflaske til GOT og for DGA - det kan være op til ca. 8-20 liter ved store krafttransformere og ca. 1-8 liter ved mindre transformere. Prøvtagningsformular udfyldes med beskrivelse af, hvor olieprøven er udtaget og om der fx er anvendt aftapningshane på bundventil og om prøverne er udtaget i forbindelse med rutine, olieskift, olieregenerering, udkobling af buchholzrelæ, andre driftsforstyrrelse eller havari. Prøvtagningsformular udfyldes med oplysning om: Dato/Tid: 2014-xx-xx; kl. cc.cc Kunde: Banedanmark Prøvetager: Navn Lokalitet: Ex St. 175 - TRF 21 Serienummer: Ex. NC 123456789 Temperatur på topolie: Ex 41 0 C Effekt: Ex. 1.250 kva Fabrikat: Ex ABB, Siemens, Pauwels - - - Effekt: Ex. 1.250 kva Primær/sekundær spænding: Ex. 10,5 / 0,4 kv Køling/Cooling: Ex ONAN ved andre cifre kan der være tale om syntetisk olie, silikone eller risiko for at olien indeholder PCB. Olievægt: ex 1.000 kg Fremstillingsår: ex. 1970. Ekspansionsbeholder/konservator eller hermetisk lukket: Ja / Nej Silicagelfilter: Ja / Nej Trinomskifter: Ja / Nej Viklingskobler: Ja / Nej Bemærkninger: ABB Nr. på Aluminumsflasken noteres i punktet: Provkärl och provtagningsställe: Eksempel på nummer F8906 7

NB! Ved efterfyldning af transformerolie skal der anvendes følgende type: Nynas Nytro 10 XN eller Shell Diala S3 ZX-I Dried. 8. Laboratorium Til test af olie prøver og anvendelse prøvetagningsbeholdere skal følgende laboratorium altid anvendes: ABB AB Power Transformers PPTR/AD Valhallavâgen 2 S-771 80Ludvika Sweden Tlf. +46 240 78 20 00 Fax: +46 240 61 15 68 e-mail: diagnostics@se.abb.com www.abb.com Prøver sendes retur til: ABB AB Power Transformers Godsmottagningenn Torg 24 S-771 80 Ludvika Dersom det er nødvendigt med andet laboratorium skal Teknisk Drift kontaktes. Banedanmark har indgået aftale med ELTEL-NETWORKS om at de kan håndterer vores olieprøver. Henvendelse sker til Andreas K Danielsen for det praktiske forløb. Andreas Danielsen Power Services Højspænding / High Voltage ELTEL Networks A/S Fabriksparken 38, 1. sal DK-2600 Glostrup, Denmark andreas.k.danielsen@eltelnetworks.com Mobile: +45 2024 4197 Tel: +45 8813 5000 www.eltelnetworks.dk 8

9. Annex A Varselsgrænse for DGA gasanalyse er listet i IEC 60599, Annex A. Overskrides koncentrationer som er angivet i tabellerne er det tegn på, at yderligere rutinemæssige DGA analyser må foretages med kortere intervaller. Her skal bemærkes særlige forhold omkring krafttransformere med separate konservator for OLTC / Viklingskobler, sugetransformere med åben konservator og hermetisk udgave. Tilsvarende vil være gældende for forsynings transformere med trinomskifter med åben konservator og hermetiske. 10. Annex B Anbefalede værdier for ny transformerolie er listet i IEC 60422, afsnit 9, tabel 3. Værdier for transformere i drift er listet i IEC 60422, afsnit 9 samt tabel 5 Application and interpretation of tests (1 of 4). Som udgangspunkt inddeles målte værdier i 3 som følger: Good Oil in normal condition; continue normal sampling. Fair Oil deterioration detectable; more frequent sampling recommended (Table 4). Poor Oil deterioration abnormal; immediate action advisable. For syretal gælder grænseværdi 0,06 mgkoh/g For IFT gælder grænseværdi <28 mn/m 9