Digital/Analog Megohmmeter Model 1026

Relaterede dokumenter
UNISONIC TECHNOLOGIES CO.,

E-PAD Bluetooth hængelås E-PAD Bluetooth padlock E-PAD Bluetooth Vorhängeschloss

TM4 Central Station. User Manual / brugervejledning K2070-EU. Tel Fax

Davo-Meg 1002 & 1002B Dansk manual Side 3-5 English user manual Page 6-8

frame bracket Ford & Dodge

DANSK INSTALLATIONSVEJLEDNING VLMT500 ADVARSEL!

WIO200A Water in oil sensor

Palm Size Multimeter

Opera Ins. Model: MI5722 Product Name: Pure Sine Wave Inverter 1000W 12VDC/230 30A Solar Regulator

MS-H280-Pro Magnetic Stirrer

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS. The DIVAR wall lamp comes standard. with 2.4 m braided cord and a plug in power supply (EU or UK).

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

WIO200A INSTALLATIONS MANUAL Rev Dato:

QUICK START Updated: 18. Febr. 2014

Brugsanvisning. Installation Manual

DIVAR VIGTIGT! / IMPORTANT! MÅL / DIMENSIONS

ROTERENDE TABURET 360 GRADER MED HYL Brugsanvisning. ROTATING SHOWER STOOL WITH TRAY Installation Manual. Size: 148 x 210 mm 105g copper paper

Assembly Instructions. ROLZ-2 Portable AV/Conference Center

INSTALLATION INSTRUCTIONS STILLEN FRONT BRAKE COOLING DUCTS NISSAN 370Z P/N /308960!

QUICK START Updated:

Sikkerhedsvejledning

Portal Registration. Check Junk Mail for activation . 1 Click the hyperlink to take you back to the portal to confirm your registration

Elma DT 802D CO2 logger. Dansk/Norsk 2 English 4 EAN:

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.

Quick Start Guide. Tek-Vor 1300C. 796 Tek Drive, Crystal Lake, IL USA

User Manual for LTC IGNOU

Bilag 8. TDC technical requirements for approval of splitterfilters and inline filters intended for shared access (ADSL or VDSL over POTS).

BRUGERVEJLEDNING TIL REVOLTA TRANSFORMER 2-WAY VOLTAGE TRANSFORMER USER MANUAL RV-2400

RPW This app is optimized for: For a full list of compatible phones please visit radiation. result.

Mandara. PebbleCreek. Tradition Series. 1,884 sq. ft robson.com. Exterior Design A. Exterior Design B.

WATER BATH I Instruction Manual. Water Bath. Digital Control. Cat. No

Project Step 7. Behavioral modeling of a dual ported register set. 1/8/ L11 Project Step 5 Copyright Joanne DeGroat, ECE, OSU 1

Metal Oxide Varistor:TVM-B Series

Lithium-Ion Jump-Starters / Jumper Cables

XXL-Rehab Stok XXL-Rehab Walking Cane

Black Jack --- Review. Spring 2012

Varenr.: højre venstre º højre med coating º venstre med coating

XXL-Rehab 4-punkt Stok XXL-Rehab 4-point Cane


TDC 4 Indoor voltage transformers

Constant Terminal Voltage. Industry Workshop 1 st November 2013

HR7775, HR indd :28

DANSK. INSTALLATIONSVEJLEDNING DS Pro Lærred med motor ADVARSEL!

XXL-Rehab 4-punkt Stok XXL-Rehab 4-point Cane

Privat-, statslig- eller regional institution m.v. Andet Added Bekaempelsesudfoerende: string No Label: Bekæmpelsesudførende

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav

Basic statistics for experimental medical researchers

Læs vejledningen godt igennem, før du begynder at samle vuggen. Please read the instruction carefully before you start.

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

Unitel EDI MT940 June Based on: SWIFT Standards - Category 9 MT940 Customer Statement Message (January 2004)

LINK-56K. Emulator for Motorola s DSPs. A Product of Domain Technologies, Inc.

Date of issue Fremstillingsdato. Machine no , Maskinnr. ALSCO SAN DIEGO

ATEX direktivet. Vedligeholdelse af ATEX certifikater mv. Steen Christensen

Digital Clamp Meter. Instruction Manual DT-9250

TELT. Oversigt over dele. Følg opstillingsanvisningerne for at opnå det bedste resultat.

United Nations Secretariat Procurement Division

Our activities. Dry sales market. The assortment

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.

Betjenings vejledning I Operator manual Tekniske data I Technical data El-tegninger I Electrical drawings. QVEX Clima. Revideret /JLK

IBM Network Station Manager. esuite 1.5 / NSM Integration. IBM Network Computer Division. tdc - 02/08/99 lotusnsm.prz Page 1

Vores mange brugere på musskema.dk er rigtig gode til at komme med kvalificerede ønsker og behov.

Recall information fra C. Reinhardt

South Baileygate Retail Park Pontefract

ELECTRONIC CONTROL BOX

R9H R9H R9H R9H R9H R9H R9H13303

Subject to terms and conditions. WEEK Type Price EUR WEEK Type Price EUR WEEK Type Price EUR WEEK Type Price EUR

Plug Connectors for Food & Beverage

Læs venligst Beboer information om projekt vandskade - sikring i 2015/2016

O-DINS-1 (Open DIN spindle set for IKA Rotavisc)

HA-SPAD MEDIA KIT

Maneurop reciprocating compressors

Specifikationer: Producer: Unitron a/s Kokmose 6, 6000 Kolding. Tlf Fax

Trolling Master Bornholm 2016 Nyhedsbrev nr. 3

Side 1 af 9. SEPA Direct Debit Betalingsaftaler Vejledning

Resource types R 1 1, R 2 2,..., R m CPU cycles, memory space, files, I/O devices Each resource type R i has W i instances.

Business Opening. Very formal, recipient has a special title that must be used in place of their name

Bookingmuligheder for professionelle brugere i Dansehallerne

Model Brugsanvisning Instruction manual

EASYLINE CV 48 V. LED Drivers CV. EasyLine 48 V C-L , Typical Applications Shop lighting for 48 V systems Furniture lighting

Chiroform Massageapparat

Help / Hjælp

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

OXFORD. Botley Road. Key Details: Oxford has an extensive primary catchment of 494,000 people

Slot diffusers. Slot diffusers LD-17, LD-18

Business Opening. Very formal, recipient has a special title that must be used in place of their name

Clear aim to ensure safety of all people involved in optical links project Scope

Skriftlig Eksamen Kombinatorik, Sandsynlighed og Randomiserede Algoritmer (DM528)

Meget formel, modtager har en meget speciel titel som skal bruges i stedet for deres navne

MultiProgrammer Manual

SEPA Direct Debit. Mandat Vejledning Nets Lautrupbjerg 10 DK-2750 Ballerup

Operation Manual SMS Air Conditioner Remote Controller Model No.: SR-001

Engelsk. Niveau D. De Merkantile Erhvervsuddannelser September Casebaseret eksamen. og

Bilag 1 GPS dataudskrifter fra Stena Carisma ved passage af målefelt

JENSEN EXTREME FEEDER

Asking whether there are commission fees when you withdraw money in a certain country

Asking whether there are commission fees when you withdraw money in a certain country

Fejlbeskeder i SMDB. Business Rules Fejlbesked Kommentar. Validate Business Rules. Request- ValidateRequestRegist ration (Rules :1)

XXL-Rehab Gulv forhøjer XXL-Rehab Floor raiser

XV1100K(C)/XV1100SK(C)

On the complexity of drawing trees nicely: corrigendum

Transkript:

Digital/Analog Megohmmeter Model 1026 USER MANUAL MEGOHMMETER MODEL 1026 MΩ V Ω TEST LOCK HOLD 4000Ω MΩ - 250V MΩ - 500V V MΩ - 1000V OFF MΩ V Ω 600V CAT III 1000V CAT II 1000V

Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications. An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge. The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: Catalog #: 2117.72 Model #: 1026 Please fill in the appropriate date as indicated: Date Received: Date Calibration Due: Chauvin Arnoux, Inc. d.b.a AEMC Instruments www.aemc.com

Limited Warranty The Megohmmeter, Model 1026, is warranted to the owner for a period of 1 year from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. Full warranty coverage and product registration is available on our website at www.aemc.com/warranty.html. Please print the online Warranty Coverage Information for your records. What AEMC Instruments will do: If a malfunction occurs within the one-year period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC Instruments will, at its option, repair or replace the faulty material. What You Must Do: First request a return authorization form by phone or by fax from AEMC Instruments, then return the instrument along with the signed authorization repair form. Return material, postage pre-paid to: Chauvin Arnoux, Inc., d.b.a. AEMC Instruments Service Department 15 Faraday Drive Dover, NH 03820 USA Tel: (800) 945-2362 (X520) (603) 749-6434 (X520) Fax: (603) 742-2346 Caution: To protect against in-transit loss, we recommend you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument.

Table of Contents Warning... 3 International Electrical Symbols... 4 Receiving Your Shipment... 4 Packaging... 4 Description... 4 Specifications... 5 General... 5 Electrical... 6 Safety... 6 Ordering Information... 7 Display Features... 7 Model 1026 Features... 8 Functions... 9 VAC Function... 9 VDC Function... 9 Low Ohm and Continuity Function... 9 Megohm Insulation Resistance Test Function... 10 Manual Mode... 10 Lock Mode... 10 Auto Power Off... 11 Maintenance... 11 Warning... 11 Battery Replacement... 11 Fuse Replacement... 11 Cleaning... 11 Repair and Calibration... 12 Technical and Sales Assistance... 12

Warning These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument. Read the following safety information carefully before attempting to operate or service the meter. Safety is the responsibility of the operator! Tests are to be carried out only on dead circuits! Check for live circuits before making resistance measurements. The megohmmeter is a source of high voltage, as is the sample connected to them. All persons performing or assisting in the tests must employ all safety precautions to prevent electrical shock to themselves and to others. AEMC considers the use of rubber gloves to be an excellent safety practice even if the equipment is properly operated and correctly grounded. When testing capacitive samples, make sure that they have been properly discharged and that they are safe to touch. Electrical equipment and cables may have sufficient capacitance to store a dangerous charge from the instrument test current. For proper discharge to occur the push-to-measure button must be in the OFF position with the lock OFF and with the sample connected between the EARTH (+) and LINE (-) terminals. On prolonged tests, the TEST button may be locked ON. Care should be taken in this mode that no damage is done if the instrument is left unattended. Megohmmeters should never be used in an explosive environment. - 3 -

International Electrical Symbols This symbol signifies that the probes are protected by double or reinforced insulation. Use only specified replacement parts when servicing the instrument. This symbol signifies CAUTION! and requests that the user refer to the user manual before using the instrument. Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous. Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Packaging Your Megohmmeter, Model 1026, consists of the following items: Megohmmeter Model 1026 Set of 8 AA batteries Set of leads with black and red alligator clips Soft carrying case User manual Description The AEMC Model 1026 (Cat.# 2117.72) is a portable multi-range megohmmeter capable of measuring insulation resistance from 1k to 4000M. It has 3 test voltages of 250, 500 and 1000V. In addition, the Model 1026 has an ohmmeter range to measure from 0.1 to 4000 with an audible tone for continuity measurement under 40. A voltmeter (safety check) with a range from 0 to 600V AC or DC is available when turned on. 4

General Specifications: Display: 3" x 1.7" (76 x 42mm) Big LCD panel with 40 segments analog bar indication. Over Range Indication: - O L - will be shown on the LCD Panel when out of range measurement is made. Low Battery Indication: The will be shown when the batteries needs to be changed. Sampling Rate: 2.5 times/sec digital display; 10 times/sec bar graph Power Source: (8) 1.5V AA size batteries Battery Life: 1000V range @ 1 M >10H 500V range @ 1 M >20H 250V range @ 1 M >30H Operating Temperature and Humidity: 0 to 40 C (32 to 104 F), below 80% RH Storage Temperature: -10 to 60 C (14 to 140 F) Dimension: 7.72" (L) 4.41" (W) 2.52" (H) 196mm (L) 112mm (W) 64mm (H) Weight: Approx. 700g (1.5 lbs) with batteries - 5 -

Electrical Specifications: AC Voltage DC Voltage Range Resolution Accuracy 600V 0.1V ± (1.5% rdg + 5 dgts) Range Resolution Accuracy 600V 0.1V ± (1% rdg + 3 dgts) Ohms (Autoranging) Range Resolution Accuracy 400 0.1 4000 Continuity beeper 1 ± (1% rdg + 5 dgts) Range Active Protection M (Autoranging) 40 600Vrms Range Resolution Accuracy 4/40/400/4000M (250V) 4/40/400/4000M (500V) 4/40/400/4000M (1000V) 1k Voltage Output: -10% to +20% of selected range Short Circuit Current: 250/500/100V: 2mA max ± (3%rdg + 5dgts < 2000M ) ± (5%rdg + 5dgts 2000M to 4000M ) Safety Specifications: IEC 1010, Cat. III, 600V, Pollution Degree 2 Altitude up to 2000 meters (6000 ft.) Indoor use only EN50081-1; EN50082-1 6

Ordering Information: Megohmmeter Model 1026... Cat. #2117.72 Accessories: Replacement Test Leads with alligator clips... Cat.# 2121.53 Soft Carrying Case.... Cat.# 2117.73 Set of 5 fuses 0.5A 600V (fast blow) 1/2 x 3/8... Cat.# 2117.74 Display Features: LOCK HOLD " $! &" &&&& K V Ω MΩ Low Battery LOCK HOLD High Voltage Output Lock Enable Data Hold Continuity Beeper Enable Analog Bargraph AC Input DC Input Polarity Indication Dangerous Voltage - 7 -

Model 1026 Features: MEGOHMMETER MODEL 1026 LOCK HOLD " $! &" &&&& V K Ω MΩ MΩ V Ω TEST LOCK HOLD " # 4000Ω MΩ - 250V MΩ - 500V! V OFF MΩ - 1000V & MΩ V Ω 600V CAT III 1000V CAT II 1000V $ % 1. LCD Display 5. Data Hold Button 2. TEST Button 6. Hi Input Terminal 3. Function Selector 7. Lo Input Terminal 4. Power Lock Button 8. Battery Compartment Cover 8

Functions ACV Function: Turn the function selector to the voltage range. Connect the black test lead to ( ) terminal and the red one to the (+) terminal. Connect the test lead to the circuit in test. Reading can be held by pressing the HOLD key. DCV Function: Turn the function selector to the voltage range. Connect the black test lead to ( ) terminal and the red one to the (+) terminal. Press the TEST button to change the mode from VAC to VDC function. Connect the test lead to the circuit in test. Reading can be held by pressing the HOLD key. Low Ohm Function and Continuity Function: Turn the function selector to the 4000 range. Connect the black test lead to ( ) terminal and the red one to the (+) terminal. Connect the test lead to the circuit in test. If the reading is less than 40, the continuity beeper will sound. Because the test current provided by the meter could reach 200mA, do not use this range to test electronic components like diodes, transistors or fuses. MegOhm Insulation Resistance Test Function: Warning: Do not test insulation on a live sample and make sure it is fully discharged before each test. The Model 1026 is equipped with VAC/DC function which may be used to check if the sample is live. Turn the function selector to desired test voltage range. The LCD displays ---- to indicate the megohmmeter is standing by. - 9 -

Connect the black test lead to the ( ) terminal and the red one to the (+) terminal. Typically, the (+) is connected to ground side of sample, if available, and if testing to reference to ground. Connect the test lead to sample. Measuring can be performed in manual power mode or power lock mode: Manual Mode: Press and hold the TEST button to activate the test voltage source until you obtain a stable reading. A periodic beeping will warn that there is high voltage output. Release the TEST button to stop test voltage output. A series of short beeps indicate that discharging is in progress. When the beeper stops, the discharge is completed. The test result will automatically be held on the display. Press the Hold key before making another test. Lock Mode: Press the LOCK button to enter the Power Lock operation mode. Press the TEST button once to activate the test voltage source. A periodic beeping will warn that there is high voltage output. The test voltage will continue to be applied until the TEST button is pressed again. Press the TEST button again to stop the test voltage output. A series of short beeps indicates that discharging is in progress. When the beeper stops, the discharge is completed. The test result will be held on the display automatically. If the test period extends longer than 3-minutes the test source will shut down automatically. OVERLOAD: When the measurement exceeds the range of the instrument - O L - is displayed. Warning: Do not activate the test before the leads are properly connected to the sample under test. Do not remove the test leads from the sample under test before the discharge process is completed. Auto Power Off When the tester is idle for thirty minutes with no function selector or button operation, it will turn itself off automatically. To turn the tester on again, turn the function selector to the OFF position, then to the selected function. 10

Maintenance Warning: For maintenance only use original factory replacement parts. To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so. Do not perform any service while the megohmmeter is connected to any circuit. To avoid electrical shock and/or damage to the megohmmeter, do not let water or other foreign agents into the case. Battery Changing When appears on the LCD, the batteries will need to be replaced. To replace the batteries, turn the function selector to the OFF position, disconnect the megohmmeter from any circuit, then open the battery compartment cover with a screwdriver. Eight AA 1.5V batteries are needed. After replacing the batteries, put the cover back on and tighten the screw. Fuse Changing: When connecting the meter under the range to a source > 10V, the protection fuse will blow the circuit and a new one will be needed. To replace the fuse, turn the function selector to the OFF position, disconnect the megohmmeter from any circuit, disconnect the test leads, remove the back cover and replace the fuse (F 0.5A 600V). Cleaning The megohmmeter may be gently cleaned with a soft damp cloth, with soap. Dry immediately after cleaning. Do not submerge the case in water. Make sure the megohmmeter and all leads are perfectly dry before any further use. - 11 -

Repair and Calibration To guarantee that your instrument complies with the factory specifications, we recommend that the megohmmeter be submitted to our factory service center at one-year intervals for recalibration, or as required by other standards. For instrument repair and calibration: Call (800) 945-2362 (603) 749-6434, (X520) Fax: (603) 742-2346 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments Service Department 15 Faraday Drive Dover NH 03820 USA (Or contact your authorized distributor.) Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are available. Note: All customers must call for an authorization number before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper use or application of this instrument, please call our technical hotline: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 www.aemc.com 12

Chauvin Arnoux, Inc. d.b.a AEMC Instruments 15 Faraday Drive Dover, NH 03820, USA www.aemc.com 99-MAN 100220 v7 05/12