Eksempel på forskellige nødvendige godkendelser og standarder (UK)

Størrelse: px
Starte visningen fra side:

Download "Eksempel på forskellige nødvendige godkendelser og standarder (UK)"

Transkript

1 Eksempel på forskellige nødvendige godkendelser og standarder (UK) Approvals and Standards Required for UK WRAS (water regulations advisory scheme) Compliance with Building regulations Part G3 Compliance with Building regulations Part F Compliance with Building regulations Part L Listing in Part L Appendix Q Compliance with Building regulations Part P EMC LVD CE

2 Eksempel på forskellige normer og standarder Heat pump standards UK BS 1306:1975 BS 1710:1984 BS : 1989 BS 7593: 2006 BS 7671:2008 BS EN :1998 BS EN :1998 BS EN :1998 Specification for copper and copper alloy pressure piping systems Specification for identification of pipelines and services Application, selection and instillation of expansion vessels and ancillary equipment for sealed water systems. Code of practice for domestic heating and hot water supply Code of practice for treatment of water in domestic hot water central heating systems Requirements for electrical installation. IEE Wiring regulations (17th edition) Copper and copper alloys. Plumbing fittings. Fittings with ends for capillary soldering or capillary brazing to copper tubes Copper and copper alloys. Plumbing fittings. Fittings with compression ends for use with copper tubes Copper and copper alloys. Plumbing fittings. Fittings with compression ends for use with plastics pipes BS EN :1998 Copper and copper alloys. Plumbing fittings. Fittings combining other end connections with capillary or compression ends BS EN :1998 BS EN 12828:2003 BS EN 14324: 2004 BS EN :2007 Copper and copper alloys. Plumbing fittings. Fittings with short ends for capillary brazing to copper tubes Heating systems in buildings. Design for water-based heating systems Brazing - Guidance on the application of brazed joints Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part 1: Terms and definitions BS EN :2007 Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part 2: Test conditions BS EN :2007 Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part 3: Test methods

3 Eksempel på forskellige normer og standarder BS EN :2004 BS EN 15332:2007 BS EN 378-1: 2008 BS EN 378-2: 2008 BS EN 378-3: 2008 BS EN 378-4: 2008 BS EN 50366:2003 BS EN :2006 Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part 4: Requirements Heating boilers - Energetic assessment of hot water storage tanks Refrigerating systems and heat pumps - Safety and environmental requirements - Part 1: Basic requirements, definitions, classification and selection criteria Refrigerating systems and heat pumps - Safety and environmental requirements - Part 2: Design, construction, testing, marking and documentation Refrigerating systems and heat pumps - Safety and environmental requirements - Part 3: Installation site and personal protection Refrigerating systems and heat pumps - Safety and environmental requirements - Part 4: Operation, maintenance, repair and recovery Household and similar electrical appliances. Electromagnetic fields. Methods for evaluation and measurement Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 1: Emission BS EN :1997, Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 2: Immunity CISPR 14-2: Product family standard BS EN Household and similar electrical appliances - Safety -- Part 1: General requirements 1:2002+A2:2006 Household and similar electrical appliances - Safety -- Part 2-40: Particular requirements for electrical heat pumps, airconditioners and dehumidifiers BS EN :2003 Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 BS EN :2006 A per phase) BS EN :2008, IEC :2008 Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection BS EN 62233:2008 BS EN 12102:2008 BS EN :2003 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure Air conditioners, heat pumps and dehumidifiers with electrically driven compressors Measurement of airborne noise Determination of the sound power level. Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors

4 Eksempel på forskellige normer og standarder BS EN :2003 BS EN :2007 Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors Compressors and condensing units for refrigeration - Performance testing and test methods - Part 2: Condensing units EN 255-3:1997/AC:1997 Heat pumps for sanitary warm water BS EN :2006 EN :2003/A1:2005 Safety of machinery - Electrical equipment of machines -- Part 1: General requirements Household and similar electrical appliances - Safety -- Part 2-21: Particular requirements for storage water heaters BS EN :2001 Electromagnetic compatibility (EMC) -- Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection EN :1995/A1:1998 EN : 1995 BS EN ISO 11203:1996 Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Electromagnetic compatibility (EMC) -- Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test Acoustics - Noise emitted by machinery and equipment - Determination of emission sound pressure levels at a work station and at other specified positions from the sound power level (ISO 11203:1995) BS EN ISO :1997 Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for small, movable sources in reverberant fields - Part 2: Methods for special reverberation test rooms (ISO :1994) BS EN :1995 Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

5 Eksempel på forskellige definitioner for opnåelse af tilskud Bedingungen die subentionen zu erhalten: A) Wärmepumpen sole-wasser oder sole-sole mit kältmittelkreislauf als erdwärmeträger= COP grösser oder gleich 3,3 bei -5 C aussentemperatur und einer kondensationsstemperatur von 35 C.(1 Les pompes à chaleur géothermiques à capteur fluide frigorigène detype sol-sol ou sol-eau ayant un coefficient de performance supérieurou égal à 3,3 pour une température d'évaporation de - 5 C et unetempérature de condensation de 35 C) B) Wärmepumpen wasser-wasser mit wasser-glycol-kreislauf als erdwärmeträger= COP grösser oder gleich 3,3 bei 0 C. bei ein- und austritt des kreislaufes und -3 C kondensationsstemperatur,ein- und austrittstemperatur zwischen 30 C. und 35 C. beim kondensator(2 Les pompes à chaleur géothermiques de type eau glycolée/eau ayant uncoefficient de performance supérieur ou égal à 3,3 pour destempératures d'entrée et de sortie d'eau glycolée de 0 C et - 3 C àl'évaporateur, et des températures d'entrée et de sortie d'eau de 30 Cet 35 C au condenseur, selon le référentiel de la norme d'essai )c)

6 Eksempel på forskellige definitioner for opnåelse af tilskud C) Wärmepumpen wasser-wasser geothermie= COP grösser oder gleich 3,3 bei einer austrittstemperatur von 10 C. und 7 C. wassertemperatur beim verdampfer. und zwischen 30 C. und 35 C. beim kondensator(3 Les pompes à chaleur géothermiques de type eau/eau ayant uncoefficient de performance supérieur ou égal à 3,3 pour destempératures d'entrée et de sortie de 10 C et 7 C d'eau àl'évaporateur, et de 30 C et 35 C au condenseur, selon le référentielde la norme d'essai )D) Wärmepumpen luft-wasser= COP grösser oder gleich 3,3 bei 7 C verdampfertemperatur, ein- und austrittstemperatur zwischen 30 C. und 35 C. beim kondensator.(4 Les pompes à chaleur air/eau ayant un coefficient de performancesupérieur ou égal à 3,3 pour une température d'entrée d'air de 7 C àl'évaporateur, et des températures d'entrée et de sortie d'eau de 30 Cet 35 C au condenseur, selon le référentiel de la norme d'essai )

7 Test af ventilationsanlæg med varmepumper Hvordan griber vi det an i Nilan? - V/ Udviklingsingeniør Ph.D Lis Jacobsen, Nilan A/S

8 Formål med testen Dokumentation for kunder og myndigheder Ydelse Funktion Sikkerhed

9 Test og dokumentation af ventilationsvarmepumper Testresultater - Ydelse COP luft-luft COP luft-vand SEL Kapacitet Temperaturvirkningsgrad Relativ COP Lækage

10 Test og dokumentation af ventilationsvarmepumper Testresultater - Funktion Comfort Hygiejne Støj Vibration Afrimning

11 Test og dokumentation Specifikke krav af ventilationsvarmepumper test af ydelse nationale myndigheder og organisationer BR10 Passivhaus (Tyskland) SAP 2005 (England) DIBt (Tyskland) Minergie P (Schweiz) Wohnbauförderung (Østrig)

12 Eksempel Passivhaus teststandard Måling og beregning af data til PHPP Lækage: EN 308 Støj: EN and EN , (31,5-8000Hz) Behagelighedskriterie: PHI Afrimning: PHI Temperaturvirkningsgrad: DIBt SEL: PHI COP L/V L/L: PHI (EN 255) Kapacitet: PHI

13 Grænseværdier Lækage: Max. 3% af middel volumenstrøm Støj: Lydeffekt overflade Lw(A): Opholdsrum 25 db(a), Bryggers 30 db(a) Behagelighedskriterie: Indblæsningstemperatur minimum 16,5 C ved t_ude = -10 C Afrimning: Kontinuerlig volumenstrøm ved t_ude = -16 C Temperaturvirkningsgrad: Minimum 75% (tør) SEL: Max. 0,45 W/m 3 h (1620 J/m 3 ) Filter klasse: Indblæsning F7, udsugning G4 COP L/V L/L: PHPP Klimadaten Standard, Grænseværdi 55 kwh/(m 2 a) Kapacitet: Balanceret luftskifte Strømsvigt Automatisk genstart driftsopsætning

14 Coefficient Skabelon of Performance tast overskrift COP luft/vand COP: EN Tappning 2. Standby PHI Prüfverfaren 1. Opladning 2. Tapning EN255-3 PHI Prüfverfaren

15 Test og Eksempel dokumentation på forskellige af ventilationsvarmepumper definitioner for temperaturvirkningsgrad Passivhaus ηeff,wrg=(t11-t12+wel/m*cp)/(t11-t12) EN 308 ηt=(t22-t21)/(t11-t21)

16 Test og dokumentation af ventilationsvarmepumper Definition på SEL-værdi? Hvilken standard? Opsætning af anlæg: Interne og eksterne modtryk. Beregning: Totale elforbrug eller elforbrug til blæsere.

17 Test og dokumentation af ventilationsvarmepumper Ydelse: EN 14511, EN 14825

18 Ydelse: EN255-3 Ydelse: EN 255-3

19 Ydelse: EN255-3 Ydelse: EN 14511, EN 255-3

20 Test og dokumentation af ventilationsvarmepumper Ydelse: EN 14511, EN 14825, EN 308, EN 255-3

21 Test og dokumentation af ventilationsvarmepumper Test faciliteter hos Nilan

22 Test og dokumentation af ventilationsvarmepumper Vores erfaringer/anbefalinger Det er vanskeligt at få et overblik over hvilke nationale krav der stilles til dokumentation De nationale krav til dokumentation er sjældent identiske Definitioner i standarderne omfatter ikke alle anlægstyper Kravene til ydelse ændres konstant, hvilket nødvendiggør nye produkter og ny dokumentation Specifikation af anlægstyper er ofte utilstrækkelig dvs. vi sammenligner æbler og pærer

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation Dansk standard DS/EN 378-2 + A1 5. udgave 2009-06-29 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation Refrigerating systems and

Læs mere

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation Dansk standard DS/EN 378-2 + A2 7. udgave 2012-10-11 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation Refrigerating systems and

Læs mere

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation Dansk standard DS/EN 378-2 + A2 6. udgave 2012-08-17 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 2: Udformning, konstruktion, prøvning, mærkning og dokumentation Refrigerating systems and

Læs mere

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 15879-1:2011

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 15879-1:2011 Dansk standard DS/EN 15879-1 1. udgave 2011-04-11 Prøvning og vurdering af varmepumper med direkte varmeveksling mellem kølesystem og jord (DX) med eldrevne kompressorer til opvarmning og/eller nedkøling

Læs mere

Varmepumper med eldrevne kompressorer Prøvning og krav til mærkning af apparater til varmt brugsvand

Varmepumper med eldrevne kompressorer Prøvning og krav til mærkning af apparater til varmt brugsvand Dansk standard DS/EN 16147 1. udgave 2011-03-14 Varmepumper med eldrevne kompressorer Prøvning og krav til mærkning af apparater til varmt brugsvand Heat pumps with electrically driven compressors Testing

Læs mere

GRÆSTRIMMER LTA350 HN 10052 Brugervejledning Læs brugervejledningen omhyggeligt, før græstrimmeren tages i brug.

GRÆSTRIMMER LTA350 HN 10052 Brugervejledning Læs brugervejledningen omhyggeligt, før græstrimmeren tages i brug. GRÆSTRIMMER LTA350 HN 10052 Brugervejledning Læs brugervejledningen omhyggeligt, før græstrimmeren tages i brug. 1 GRÆSTRIMMERENS HOVEDDELE 1. Håndtag 2. Startkontakt 3. Kabelholder 4. Kabel og stik 5.

Læs mere

Varmtvandspumper Prøvning og ydeevneangivelse Del 2: Vand-til-vand- og saltvandtil-vand-varmepumper

Varmtvandspumper Prøvning og ydeevneangivelse Del 2: Vand-til-vand- og saltvandtil-vand-varmepumper Dansk Standard DS/ISO 13256-2 1. udgave 2002-06-20 Varmtvandspumper Prøvning og ydeevneangivelse Del 2: Vand-til-vand- og saltvandtil-vand-varmepumper Water-source heat pumps Testing and rating for performance

Læs mere

Fundamentals of HVAC Control Systems

Fundamentals of HVAC Control Systems ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 4 Sensors and Auxiliary Devices 2007 ASHRAE Hong

Læs mere

Elektriske apparater forbundet til vandforsyningen. Undgåelse af tilbagesugning og fejl på slangesæt

Elektriske apparater forbundet til vandforsyningen. Undgåelse af tilbagesugning og fejl på slangesæt Dansk Standard DS/EN 61770 2. udgave Godkendt:2000-05-29 COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61770:2000 Elektriske apparater forbundet til vandforsyningen. Undgåelse

Læs mere

Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper

Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper Billigere og bedre varme til virksomheder Samsung PAC og Big Ceiling varmepumper Til STOR glæde Nye varmepumper til store rum baner vejen for besparelser og et bedre indeklima. Også i støvede omgivelser.

Læs mere

UNISONIC TECHNOLOGIES CO.,

UNISONIC TECHNOLOGIES CO., UNISONIC TECHNOLOGIES CO., 3 TERMINAL 1A NEGATIVE VOLTAGE REGULATOR DESCRIPTION 1 TO-263 The UTC series of three-terminal negative regulators are available in TO-263 package and with several fixed output

Læs mere

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 15091-02

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 15091-02 Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 15091-02 For VA-godkendelse af armaturer med elektronisk åbne-lukkefunktion Page 1 of 11 INDHOLDSFORTEGNELSE FORORD... 3 ÆNDRINGER OG TILFØJELSER...

Læs mere

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted Dansk standard DS/ISO 5149-3 1. udgave 2014-04-30 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted Refrigerating systems and heat pumps Safety and environmental requirements

Læs mere

Supermarkeder og Smart Grid muligheder for fleksibelt elforbrug

Supermarkeder og Smart Grid muligheder for fleksibelt elforbrug Supermarkeder og Smart Grid muligheder for fleksibelt elforbrug Torben Funder-Kristensen Refrigeration and Air Conditioning Controls 1 Department (slide master) www.danfoss.com Agenda Cold Food Chain Trends

Læs mere

Bestemmelse af støjniveauet for aircondition og varmepumper Del 2: Ikke-kanalført, indendørs udstyr

Bestemmelse af støjniveauet for aircondition og varmepumper Del 2: Ikke-kanalført, indendørs udstyr Dansk Standard Godkendelsesblad DS/ISO 13261-2 1. udgave 2002-06-26 Bestemmelse af støjniveauet for aircondition og varmepumper Del 2: Ikke-kanalført, indendørs udstyr Sound power rating of air-conditioning

Læs mere

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 817-02

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 817-02 Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 817-02 For VA-godkendelse af et-grebs blandearmaturer. Page 1 of 11 INDHOLDSFORTEGNELSE FORORD... 3 ÆNDRINGER OG TILFØJELSER... 3 REFERENCER...

Læs mere

Varmepumper med eldrevne kompressorer Prøvning og krav til mærkning af apparater til varmt brugsvand

Varmepumper med eldrevne kompressorer Prøvning og krav til mærkning af apparater til varmt brugsvand Dansk standard Rettelsesblad DS/EN 16147/AC 1. udgave 2011-12-19 Varmepumper med eldrevne kompressorer Prøvning og krav til mærkning af apparater til varmt brugsvand Heat pumps with electrically driven

Læs mere

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf JOB NOTES TYPE APPROVALS FEATURES Three beam patterns Wide, Vertical and Narrow Flood generate high efficiencies and outstanding uniformity of illumination. 350 or 500mA current 3000K, 4000K or 5000K color

Læs mere

Bygningsreglementet BR10. BR 10 Kapitel 8.6.4

Bygningsreglementet BR10. BR 10 Kapitel 8.6.4 Regler, energimærkning og SCOP Teknologisk Institut, Århus Dato: d. 25/9-2014 Bygningsreglementet BR10 BR 10 Kapitel 8.6.4 Bygningsreglementet BR10 For varmepumper til væskebaserede centralvarmesystemer

Læs mere

KALK- OG TEGLVÆRKSFORENINGEN. CPR Sustainable Construction

KALK- OG TEGLVÆRKSFORENINGEN. CPR Sustainable Construction CPR Sustainable Construction 1 Tommy Bisgaard - Direktør i Kalk- og Teglværksforeningen - Formand for DS 417 (CEN TC350 & 351) - Formand for miljøkomiteen i TBE & CU (keramiske industrier i Europa) - Medlem

Læs mere

Elektromagnetisk kompatibilitet (EMC) Del 6-3: Generiske standarder Emissionsstandard for bolig-, erhvervsog letindustrimiljøer

Elektromagnetisk kompatibilitet (EMC) Del 6-3: Generiske standarder Emissionsstandard for bolig-, erhvervsog letindustrimiljøer Dansk standard DS/EN 61000-6-3 2. udgave 2007-02-19 Elektromagnetisk kompatibilitet (EMC) Del 6-3: Generiske standarder Emissionsstandard for bolig-, erhvervsog letindustrimiljøer Electromagnetic compatibility

Læs mere

Standarder og køreplan for udvikling af metoder til karakterisering af nanomaterialer

Standarder og køreplan for udvikling af metoder til karakterisering af nanomaterialer Standarder og køreplan for udvikling af metoder til karakterisering af nanomaterialer Europa Kommissionen har gennem mandat M461 inviteret de europæiske standardiseringsorganer til at samarbejde om udviklingen

Læs mere

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System CERTIFICATE Panasonic Fire & Security Europe AB Jungmansgatan 12 SE 211 19 Malmö Sweden Certifikat nr. Certificate no. 232.258 har på baggrund af vurderede systemegenskaber baseret på systemprøvningsrapport(er)

Læs mere

Hjælpemidler til personer med funktionsevnenedsættelse

Hjælpemidler til personer med funktionsevnenedsættelse Dansk standard DS/EN 12182 4. udgave 2012-12-21 Hjælpemidler til personer med funktionsevnenedsættelse Generelle krav og prøvningsmetoder Assistive products for persons with disability General requirements

Læs mere

Pakkemaskiner Sikkerhed Del 9: Metoder til støjmåling af pakkemaskiner, pakkelinjer og hjælpeudstyr, nøjagtighedsklasse 2 og 3

Pakkemaskiner Sikkerhed Del 9: Metoder til støjmåling af pakkemaskiner, pakkelinjer og hjælpeudstyr, nøjagtighedsklasse 2 og 3 Dansk standard DS/EN 415-9 1. udgave 2009-10-21 Pakkemaskiner Sikkerhed Del 9: Metoder til støjmåling af pakkemaskiner, pakkelinjer og hjælpeudstyr, nøjagtighedsklasse 2 og 3 Safety of packaging machines

Læs mere

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav

Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Dansk standard Tillæg DS/IEC 60335-1/A1:2013 + Corr 1:2014 1. udgave 2014-05-08 Elektriske apparater til husholdningsbrug o.l. Sikkerhed Del 1: Generelle krav Household and similar electrical appliances

Læs mere

Godkendelse af medicinsk udstyr med radio

Godkendelse af medicinsk udstyr med radio Godkendelse af medicinsk udstyr med radio Jakob Steensen Notified Body EMC DIR2014/30/EU & RE DIR2014/53/EU National Certification Body, IECEE CB Scheme Vice President, Business Unit Executive Product

Læs mere

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V.

Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Filtering on Wires Cable Ferrites, Usage & Comparison Alex Snijder Field Application Engineer Wurth Elektronik Nederland B.V. Agenda Electromagnetic Compatibility (EMC) Application of Cable Ferrites Impedance

Læs mere

ISO-standarder for sikkerhed på store og små anlæg. Dansk Træpillekonference 2015 Niels Peter K. Nielsen

ISO-standarder for sikkerhed på store og små anlæg. Dansk Træpillekonference 2015 Niels Peter K. Nielsen ISO-standarder for sikkerhed på store og små anlæg Dansk Træpillekonference 2015 Niels Peter K. Nielsen nipkn@dongenergy.dk ISO standarder indenfor sikkerhed og træpillehåndtering: Arbejdstitler: 1. Safe

Læs mere

Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper

Billigere og bedre varme til virksomheder. Samsung PAC og Big Ceiling varmepumper Billigere og bedre varme til virksomheder Samsung PAC og Big Ceiling varmepumper Til STOR glæde Nye varmepumper til store rum baner vejen for besparelser og et bedre indeklima. Også i støvede omgivelser.

Læs mere

Intelligent Glazed Facades

Intelligent Glazed Facades Frederik V. Winther M.Sc. Indoor Environmental Engineering PhD Fellow (2009-2012) fvw@ramboll.dk / fvw@civil.aau.dk Rambøll Danmark / Aalborg Universitet Institut for Byggeri og Anlæg 25-01-2013 www.zeb.aau.dk

Læs mere

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package

ME6212. High Speed LDO Regulators, High PSRR, Low noise, ME6212 Series. General Description. Typical Application. Package High Speed LDO Regulators, High PSRR, Low noise, Series General Description The series are highly accurate, low noise, CMOS LDO Voltage Regulators. Offering low output noise, high ripple rejection ratio,

Læs mere

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 1111-01

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 1111-01 Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 1111-01 For VA-godkendelse af Termostatiske blandingsventiler. Page 1 of 11 INDHOLDSFORTEGNELSE FORORD... 3 ÆNDRINGER OG TILFØJELSER... 3 REFERENCER...

Læs mere

Energy-saving potential A case study of the Danish building stock. Kim B. Wittchen Danish Building Research Institute, SBi AALBORG UNIVERSITY

Energy-saving potential A case study of the Danish building stock. Kim B. Wittchen Danish Building Research Institute, SBi AALBORG UNIVERSITY Energy-saving potential A case study of the Danish building stock Kim B. Wittchen Danish Building Research Institute, SBi AALBORG UNIVERSITY Short and long term potentials Potential energy savings on short

Læs mere

www.ic-electronic.com

www.ic-electronic.com www.ic-electronic.com Soft starter med indbygget motorbeskyttelse, strøm og spændingskontrol 3 faset kontrolleret med indbygget by-pass Nominel driftspænding 400VAC Frekvens 45... 65Hz selvindstilling

Læs mere

Cycles Electrically power assisted cycles EPAC Bicycles

Cycles Electrically power assisted cycles EPAC Bicycles Dansk standard DS/EN 15194 1. udgave 2009-02-10 Cykler Cykler med elektrisk hjælpemotor EPAC-cykler Cycles Electrically power assisted cycles EPAC Bicycles DS/EN 15194 København DS projekt: M203832 ICS:

Læs mere

Family of R744 control valves and suggestions for efficient testing

Family of R744 control valves and suggestions for efficient testing Family of R744 control valves and suggestions for efficient testing Norbert Stulgies, Axel Müller, Horst Kappler, Timo Greeb, Wilhelm Tegethoff, Sven Försterling, Jürgen Köhler 1 Contents 1. Motivation

Læs mere

RÅDET FOR DIGITAL SIKKERHED

RÅDET FOR DIGITAL SIKKERHED RÅDET FOR DIGITAL SIKKERHED Retsudvalget 2014-15 REU Alm.del Bilag 21 Offentligt Retsudvalgets høring om myndigheders behandling af personoplysninger Sikkerheden i den outsourcede it-drift Christiansborg,

Læs mere

WIO200A Water in oil sensor

WIO200A Water in oil sensor WIO200A Water in oil sensor Datasheet 111688-900 Rev. 1.03 Dato: 2012-06-01 03-01-0501-CRJ-04 Side 1 af 13 Technical Sensor Data Order Order number A01-110-0101-01 Output Analogue output 4 20 ma (galvanic

Læs mere

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted og personlig beskyttelse

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted og personlig beskyttelse Dansk standard DS/EN 378-3 4. udgave 2008-10-20 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted og personlig beskyttelse Refrigerating systems and heat pumps Safety and environmental

Læs mere

WI180C-PB. Online-datablad

WI180C-PB. Online-datablad Online-datablad A B C D E F H I J K L M N O P Q R S T Oversigt over tekniske data Tekniske data Tilbehørsfamilie Henvisning Kapslingsklasse Dimensioner (B x H x L) Beskrivelse Klassifikationer Bestillingsoplysninger

Læs mere

Spare parts ASC 3500 G V7 SKU:

Spare parts ASC 3500 G V7 SKU: Front view ASC 3500 G Process display 4. LED ASC Art.Nr.:4441600184 LP gauge ASC Art.Nr.:4440600221 Cover gauge group Art.Nr.:4443900278 Printer ASC G-Version Art.Nr.:4441600178 Paper for printer 4x ASC

Læs mere

Dansk Standard DS/EN 60349-1 1. udgave

Dansk Standard DS/EN 60349-1 1. udgave Dansk Standard DS/EN 60349-1 1. udgave Godkendt:2001-03-29 COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 60349-1:2001 Elektrisk traktion Roterende elektriske maskiner til jernbane-

Læs mere

Airconditionanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 2: Prøvningsbetingelser

Airconditionanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 2: Prøvningsbetingelser Dansk standard DS/EN 14511-2 4. udgave 2013-10-25 Airconditionanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 2: Prøvningsbetingelser Air conditioners, liquid

Læs mere

Lovkrav vs. udvikling af sundhedsapps

Lovkrav vs. udvikling af sundhedsapps Lovkrav vs. udvikling af sundhedsapps Health apps give patients better control User Data Social media Pharma Products User behaviour Relatives www Self monitoring (app) data extract Healthcare specialists

Læs mere

varmt brugsvand i køretøjer og både

varmt brugsvand i køretøjer og både Dansk standard DS/EN 15033 1. udgave 2006-12-13 Rumforseglede LPG-forrådsvandvarmere til produktion af varmt brugsvand i køretøjer og både Room sealed storage water heaters for the production of sanitary

Læs mere

Undersøgelse af danske institutters og firmaers muligheder for at servicere danske virksomheder inden for typeprøvning af legale måleinstrumenter

Undersøgelse af danske institutters og firmaers muligheder for at servicere danske virksomheder inden for typeprøvning af legale måleinstrumenter Undersøgelse af danske institutters og firmaers muligheder for at servicere danske virksomheder inden for typeprøvning af legale måleinstrumenter Rapport nr.: CLM 014A/2003 19. september 2003 DELTA Dansk

Læs mere

Statistical information form the Danish EPC database - use for the building stock model in Denmark

Statistical information form the Danish EPC database - use for the building stock model in Denmark Statistical information form the Danish EPC database - use for the building stock model in Denmark Kim B. Wittchen Danish Building Research Institute, SBi AALBORG UNIVERSITY Certification of buildings

Læs mere

Spare parts ASC 3500 G LE V6 SKU:

Spare parts ASC 3500 G LE V6 SKU: Front view ASC 3500 G LE Process display 4. LED ASC Art.Nr.:4441600184 LP gauge ASC Art.Nr.:4440600221 Cover gauge group Art.Nr.:4443900278 Printer ASC G-Version Art.Nr.:4441600178 Paper for printer 4x

Læs mere

Hvordan benyttes standarder i forbindelse med lovgivning? - Kristian Baasch Thomsen - Per Rafn Crety

Hvordan benyttes standarder i forbindelse med lovgivning? - Kristian Baasch Thomsen - Per Rafn Crety Hvordan benyttes standarder i forbindelse med lovgivning? - Kristian Baasch Thomsen - Per Rafn Crety Forkortelser mv. Engelsk Dansk Annex Bilag Regulation Forordning DOC Declaration of Conformity Overensstemmelseserklæring

Læs mere

BRUGERVEJLEDNING. Elektrisk tryksprøjte SX-MD5 HN5519

BRUGERVEJLEDNING. Elektrisk tryksprøjte SX-MD5 HN5519 BRUGERVEJLEDNING Elektrisk tryksprøjte SX-MD5 HN5519 Pas på denne brugervejledning og hold den i god stand. For at benytte og vedligeholde sprøjten korrekt, så læs vejledningen omhyggeligt, før sprøjten

Læs mere

Klimaanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 3: Prøvningsmetoder

Klimaanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 3: Prøvningsmetoder Dansk standard DS/EN 14511-3 3. udgave 2012-01-04 Klimaanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 3: Prøvningsmetoder Air conditioners, liquid chilling

Læs mere

Slot diffusers. Slot diffusers LD-17, LD-18

Slot diffusers. Slot diffusers LD-17, LD-18 LD-17, LD-18 Application LD-17 and LD-18 are designed for supply of cold or warm air in rooms with a height between. m and 4 m. They allow easy setting of air deflectors for different modes of operation

Læs mere

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG

Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG Specifikke VA-Prøvnings- og Godkendelsesbetingelser VA PG 200-01 For VA-godkendelse af aftapnings- og blandingsventiler. Page 1 of 11 INDHOLDSFORTEGNELSE FORORD... 3 ÆNDRINGER OG TILFØJELSER... 3 REFERENCER...

Læs mere

Rasmus Banke Banke Accessory Drives

Rasmus Banke Banke Accessory Drives Dakofa 2014 Rasmus Banke Banke Accessory Drives Agenda Lidt om Banke Accessory Drives Baggrund og produkter Meldgaard og Ringkøbing-Skjern kommune idriftsætter landets første Gas/El-hybrid Skraldebiler

Læs mere

Vejledning for TKE 01 Ver 4.01

Vejledning for TKE 01 Ver 4.01 Vejledning for TKE 01 Ver 4.01 TKE-01 er lavet specielt til at arbejde sammen med en Calyma ventilationunit med Lemmens DC-motorer. POWER ON SPJÆLD LUKKET FEJL TRYKFEJL VARME STYRING under 18 grader Temperatur

Læs mere

Ventilation i bygninger Ydeevneprøvning af komponenter/produkter til boligventilation Del 11: Forsyningsenheder

Ventilation i bygninger Ydeevneprøvning af komponenter/produkter til boligventilation Del 11: Forsyningsenheder Dansk standard DS/EN 13141-11:2015 1. udgave 2015-06-15 Ventilation i bygninger Ydeevneprøvning af komponenter/produkter til boligventilation Del 11: Forsyningsenheder Ventilation for buildings Performance

Læs mere

Maneurop reciprocating compressors

Maneurop reciprocating compressors MAKING MODERN LIVING POSSIBLE Maneurop reciprocating compressors MT - MTZ - LTZ - NTZ - 60 z R404A - R507A - R407C - R134a - R22 QUICK REFERENCE PRODUCT RANGE Nominal voltage M-BP Applications LBP Applications

Læs mere

Rekommandation 16. Spændingskvalitet i lavspændingsnet 4. udgave, August Dansk Energi. Forskning og Udvikling.

Rekommandation 16. Spændingskvalitet i lavspændingsnet 4. udgave, August Dansk Energi. Forskning og Udvikling. Rekommandation 16 Spændingskvalitet i lavspændingsnet 4. udgave, August 2011 Dansk Energi Forskning og Udvikling Rosenørns Allé 9 1970 Frederiksberg C Tlf.: 35 300 770 Fax: 35 300 771 E-mail: info@defu.dk

Læs mere

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 4: Drift, vedligeholdelse, reparation og genvinding af kølemiddel

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 4: Drift, vedligeholdelse, reparation og genvinding af kølemiddel Dansk standard DS/EN 378-4 + A1 5. udgave 2012-08-17 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 4: Drift, vedligeholdelse, reparation og genvinding af kølemiddel Refrigerating systems and

Læs mere

Fjerde Generation Fjernvarme

Fjerde Generation Fjernvarme Dansk Fjernvarmes 56. landsmøde Aalborg Kongres & Kultur Center, 30-31. oktober 2014 Fremtidens fjernvarmesystem Fjerde Generation Fjernvarme Professor Henrik Lund, Aalborg Universitet 4DH Forskningscenter

Læs mere

Varme- og køleanlæg i bygninger Metode til beregning af varmepumpesystemers ydeevne og konstruktion Del 1: Konstruktion og dimensionering

Varme- og køleanlæg i bygninger Metode til beregning af varmepumpesystemers ydeevne og konstruktion Del 1: Konstruktion og dimensionering Dansk standard DS/ISO 13612-1 1. udgave 2014-05-14 Varme- og køleanlæg i bygninger Metode til beregning af varmepumpesystemers ydeevne og konstruktion Del 1: Konstruktion og dimensionering Heating and

Læs mere

TDC 4 Indoor voltage transformers

TDC 4 Indoor voltage transformers Medium Voltage Product TDC 4 Indoor voltage transformers Highest voltage for equipment [kv] 3.6-12 Power frequency test voltage, 1 min. [kv] 10 - Lightning impulse test voltage [kv] Max. rated burden,

Læs mere

Heating systems in buildings Design of heat pump heating systems

Heating systems in buildings Design of heat pump heating systems Dansk standard DS/EN 15450 1. udgave 2007-11-30 Varmesystemer i bygninger Projektering af varmepumpesystemer Heating systems in buildings Design of heat pump heating systems DS/EN 15450 København DS projekt:

Læs mere

Metal Oxide Varistor:TVM-B Series

Metal Oxide Varistor:TVM-B Series Features 1. RoHS compliant 2. High surge suppress capability 3. EIA size 0402 ~ 2220 4. Operating voltage: 5.5 ~ 85 Vdc 5. Bidirectional and symmetrical V/I characteristics 6. Multilayer ceramic construction

Læs mere

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals

Product. Information. A. u. K. Müller. 2/2-way Drain Valve NC, DN 40. Series Characteristics. Possible approvals Solenoid valves Control valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)1-73-0 Fax: +49(0)1-73-281 e-mail: info@akmueller.de Internet: www.akmueller.de

Læs mere

Spare parts ASC 3000 G V11 SKU:

Spare parts ASC 3000 G V11 SKU: Spare parts ASC 3000 G Prozessanzeige LED ASC Art.Nr.:4441600088 Low pressure gauge ASC Art.Nr.:4440600046 Cover gauge group Art.Nr.:4443900278 Printer ASC G-Version Art.Nr.:4441600178 Paper for printer

Læs mere

Ventilation for buildings Air handling units Rating and performance for units, components and sections

Ventilation for buildings Air handling units Rating and performance for units, components and sections Dansk standard DS/EN 13053 2. udgave 2006-09-27 Ventilation i bygninger Luftbehandlingsanlæg Ydelse og ydeevne for anlæg, komponenter og sektioner Ventilation for buildings Air handling units Rating and

Læs mere

Specifikationer for drikkevandsinstallationer

Specifikationer for drikkevandsinstallationer Dansk standard DS/EN 806-5:2013 2. udgave 2013-11-04 Specifikationer for drikkevandsinstallationer i bygninger Del 5: Drift og vedligehold Specifications for installations inside buildings conveying water

Læs mere

CKE-21 Software version 21.01B

CKE-21 Software version 21.01B CKE-21 Software version 21.01B CKE-21 er en Calyma Kontrol Enhed der er udviklet til energiøkonomisk drift af DC motorer i Calyma ventilationsunit, og samtidig er der kontrol over en blandefunktion som

Læs mere

Hvordan kan man påvirke krav og regler i standarder. Mandag d. 5. november 2018

Hvordan kan man påvirke krav og regler i standarder. Mandag d. 5. november 2018 Hvordan kan man påvirke krav og regler i standarder Mandag d. 5. november 2018 Indhold Hvad er Dansk Standard Dansk standard og det internationale netværk Organisering/Niveauer for indflydelse Sammenhæng

Læs mere

Medlem af EA MLA AKKREDITERING. til certificering af ledelsessystemer. Reg. nr Intertek DIC A/S Buen 12, 3. sal, 6000 Kolding CVR:

Medlem af EA MLA AKKREDITERING. til certificering af ledelsessystemer. Reg. nr Intertek DIC A/S Buen 12, 3. sal, 6000 Kolding CVR: Medlem af EA MLA AKKREDITERING til certificering af ledelsessystemer Reg. nr. 5015 Virksomhed Intertek DIC A/S Buen 12, 3. sal, 6000 Kolding CVR: 20292040 Akkrediteringsområde Gyldighedsperiode Erstatter

Læs mere

1. Ledningskanaler (IEC SC 23A)

1. Ledningskanaler (IEC SC 23A) 1. Ledningskanaler (IEC SC 23A) IEC 23A udarbejder bestemmelser for kabelføringsmateriel som kabelkanaler, kabelbakker, kabelstiger og rør som bruges til at understøtte, beskytte eller lægge kabler etc.

Læs mere

Varmepumpe udviklet specielt til mindre havebassiner

Varmepumpe udviklet specielt til mindre havebassiner EAN 5704841010673 1067 Swim & fun scandinavia ApS DK Heat Pump HotSplash Varmepumpe udviklet specielt til mindre havebassiner Miljøvenlig letvægts varmepumpe som man selv nemt kan installere. Det lave

Læs mere

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System CERTIFICATE Pro-Sec A/S Egegårdsvej 11 4621 Gadstrup Certifikat nr. Certificate no. 232.275 har på baggrund af vurderede systemegenskaber baseret på systemprøvningsrapport(er) for overensstemmelse mellem

Læs mere

Ventilation i bygninger Ydeevneprøvning af komponenter/produkter til boligventilation Del 8: Ydeevneprøvning

Ventilation i bygninger Ydeevneprøvning af komponenter/produkter til boligventilation Del 8: Ydeevneprøvning Dansk standard DS/EN 13141-8 1. udgave 2006-05-04 Ventilation i bygninger Ydeevneprøvning af komponenter/produkter til boligventilation Del 8: Ydeevneprøvning af mekanisk tillufts/fraluftsaggregat med

Læs mere

Gasmålere Udstyr til omregning Del 2: Energiomregning

Gasmålere Udstyr til omregning Del 2: Energiomregning Dansk standard DS/EN 12405-2 1. udgave 2012-09-28 Gasmålere Udstyr til omregning Del 2: Energiomregning Gas meters Conversion devices Part 2: Energy conversion DS/EN 12405-2 København DS projekt: M242352

Læs mere

Airconditionanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 3: Prøvningsmetoder

Airconditionanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 3: Prøvningsmetoder Dansk standard DS/EN 14511-3 4. udgave 2013-10-25 Airconditionanlæg, væskekølere og varmepumper med eldrevne kompressorer til rumopvarmning og rumkøling Del 3: Prøvningsmetoder Air conditioners, liquid

Læs mere

Central Statistical Agency.

Central Statistical Agency. Central Statistical Agency www.csa.gov.et 1 Outline Introduction Characteristics of Construction Aim of the Survey Methodology Result Conclusion 2 Introduction Meaning of Construction Construction may

Læs mere

Programmable pressure transmitters PTM

Programmable pressure transmitters PTM Programmable pressure transmitters PTM Version: 07.01.2016 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5... 2 > 2... 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure

Læs mere

ER FLEXGAS II-LØSNINGERNE ET REALISTISK BUD PÅ BEDRE UDNYTTELSE AF VE-STRØM?

ER FLEXGAS II-LØSNINGERNE ET REALISTISK BUD PÅ BEDRE UDNYTTELSE AF VE-STRØM? ER FLEXGAS II-LØSNINGERNE ET REALISTISK BUD PÅ BEDRE UDNYTTELSE AF VE-STRØM? Kasper Korsholm Østergaard, R&D Manager, METRO THERM Gastekniske dage 2018, 8-9. maj, Billund FLEXGAS II: PARTNERE OG SPONSOR

Læs mere

Condition Monitoring Project

Condition Monitoring Project Projekt Oil Condition Monitoring 1 www.cjc.dk Projekt Oil Condition Monitoring Skibsteknisk Selskabs konference, 7. oktober 2013 Den Danske Maritime Fond Jens Fich, General Technical Manager, C.C.JENSEN

Læs mere

AC-Sun. Nyt koncept for klimaanlæg. www.ac-sun.com. Solar Thermal AC

AC-Sun. Nyt koncept for klimaanlæg. www.ac-sun.com. Solar Thermal AC Solar Thermal AC Nyt koncept for klimaanlæg www.ac-sun.com Virksomhedsprofil AC-Sun blev etableret som et selskab sidst i 2005 med den vision og formål at udvikle en revolutionerende ny generation af klimaanlæg

Læs mere

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation

PEMS RDE Workshop. AVL M.O.V.E Integrative Mobile Vehicle Evaluation PEMS RDE Workshop AVL M.O.V.E Integrative Mobile Vehicle Evaluation NEW - M.O.V.E Mobile Testing Platform Key Requirements for Measuring Systems Robustness Shock / vibrations Change of environment Compact

Læs mere

Pompes à vide lubrifie es EVE-OG

Pompes à vide lubrifie es EVE-OG Adaptable à tous secteurs d'activite s Application Pompe pour les applications les plus diverses dans le secteur de la manipulation automatique et manuelle Manipulation de pie ces e tanches et poreuses

Læs mere

CERTIFIKAT CERTIFICATE

CERTIFIKAT CERTIFICATE CERTIFIKAT CERTIFICATE GODKENDELSE NR. / APPROVAL NO.: 04/00141 UDSTEDT / DATE OF ISSUE: 31-10-2017 UDLØBER / EXPIRY DATE: 30-10-2022 Dette certifikat er udstedt i henhold til bekendtgørelse nr. 1007 af

Læs mere

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted og personbeskyttelse

Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted og personbeskyttelse Dansk standard DS/EN 378-3 + A1 6. udgave 2012-10-11 Kølesystemer og varmepumper Sikkerheds- og miljøkrav Del 3: Installationssted og personbeskyttelse Refrigerating systems and heat pumps Safety and environmental

Læs mere

Coatinganlæg Kombinerede kabiner Sikkerhedskrav

Coatinganlæg Kombinerede kabiner Sikkerhedskrav Dansk standard DS/EN 13355 + A1 2. udgave 2009-06-08 Coatinganlæg Kombinerede kabiner Sikkerhedskrav Coating plants Combined booths Safety requirements DS/EN 13355 + A1 København DS projekt: M239722 ICS:

Læs mere

Tommy Græsborg Nielsen, CMSE Certified Machinery Safety Expert (TÜV Nord) Safety Engineer

Tommy Græsborg Nielsen, CMSE Certified Machinery Safety Expert (TÜV Nord) Safety Engineer Tommy Græsborg Nielsen, CMSE Certified Machinery Safety Expert (TÜV Nord) Safety Engineer togn@bowitek.dk Tlf.: +45 27 88 06 63 Bowitek: - Rådgivning indenfor CE mærkning - MD, Atex, arb. miljø, verificering,

Læs mere

[da] Krav til sikkerhedsudstyr for varmtvandskedel 2 [en] Safety equipment requirements for hot water boilers 6

[da] Krav til sikkerhedsudstyr for varmtvandskedel 2 [en] Safety equipment requirements for hot water boilers 6 8 0,5 % 6/7 11 3 4 5 15 10 9 P 13 1 13 14 15 16 13 17 6 70 808 634-00.1T [da] Krav til sikkerhedsudstyr for varmtvandskedel [en] Safety equipment requirements for hot water boilers 6 Anlægseksempler 1

Læs mere

Screened electronic cable LiYCY

Screened electronic cable LiYCY Screened electronic cable LiYCY Conductor material: copper, bare Conductor class: class 5 = fine stranded Insulation: PVC Screen: copper braid, tinned Screen coverage: 70 % Sheathing material: PVC Flame-retardant:

Læs mere

Batterisystemer og godkendelse

Batterisystemer og godkendelse Batterisystemer og godkendelse Batterisystemer og godkendelse Krav til batterisystemer? I forhold til applikation Elbiler BESS Godkendelse Batterisystemer UN-ECE Regulation 100 re 2 Uniform provisions

Læs mere

Kølesystemer og varmepumper Ventiler Krav, prøvning og mærkning

Kølesystemer og varmepumper Ventiler Krav, prøvning og mærkning Dansk standard DS/EN 12284 1. udgave 2003-10-23 Kølesystemer og varmepumper Ventiler Krav, prøvning og mærkning Refrigerating systems and heat pumps Valves Requirements, testing and marking DS/EN 12284

Læs mere

DTU test center for hygiejnisk design anvendelse i undervisningen

DTU test center for hygiejnisk design anvendelse i undervisningen 7.11.2012 DTU test center for hygiejnisk design anvendelse i undervisningen Per Væggemose Nielsen IPU Søltofts Plads, Building 221 pvn@ipu.dk 452 52631 / 2962 0843 Agenda Introduktion Anvendelse af Test

Læs mere

Elektriske apparater forbundet til vandforsyningen Undgåelse af tilbagesugning og fejl på slangesæt

Elektriske apparater forbundet til vandforsyningen Undgåelse af tilbagesugning og fejl på slangesæt Dansk standard Rettelsesblad DS/EN 61770/Corr. Mar. 2011 1. udgave 2011-04-06 COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61770/Corr. Mar. 2011:2011 Elektriske apparater forbundet

Læs mere

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support:

H07RN-F CPR BESKRIVELSE STANDARDER. Kontakter Installation Tlf.: Support: Industrial flexible rubber cable range with an insulation and sheath in elastomers. Cables for heavy duty uses, Oil resistant and Flame retardancy according to IEC/EN 60332-1-2 standard. BESKRIVELSE Application

Læs mere

132-400 kv AC Station

132-400 kv AC Station teknisk standard 132-400 kv AC Station Kontrolanlæg Generelt ETS-52-00 Rev. 0 REVISIONSOVERSIGT Dokumentnummer: 24828/10 Version Forfatter Dokument status/ændring Reviewer Godkender Dato PDI, MOG, MOG,

Læs mere

Heating boilers Electrical power consumption for heat generators System boundaries Measurements

Heating boilers Electrical power consumption for heat generators System boundaries Measurements Dansk standard DS/EN 15456 1. udgave 2008-05-13 Varmekedler Varmegeneratorers elforbrug Systemafgrænsning Målinger Heating boilers Electrical power consumption for heat generators System boundaries Measurements

Læs mere

LED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit. www.osram.com 1. HOW CAN I UNDERSTAND THE FOLLOWING SHEETS?

LED STAR PIN G4 BASIC INFORMATION: Series circuit. Parallel circuit. www.osram.com 1. HOW CAN I UNDERSTAND THE FOLLOWING SHEETS? BASIC INFORMATION: 1. HOW CAN I UNDERSTAND THE FOLLOWING SHES? Compatibility to OSRAM s: -Series Circuit... Page 2 -Parallel Circuit... Page 3 Compatibility to OTHER s : -Series Circuit... Page 4 -Parallel

Læs mere

Cooking Plate EV816. Type of Cooking Plate : Electric Number of Cooking plates : 1

Cooking Plate EV816. Type of Cooking Plate : Electric Number of Cooking plates : 1 Cooking Plate EV816 Color : Type of Cooking Plate : Stainless Steel Electric Number of Cooking plates : 1 Diameter Large Cooking plate ( mm ) : 187 Power Large Cooking plate ( Watt ) : 1500 Diameter Small

Læs mere